INNERSHIELD WIRES PRODUCT CATALOG

Self-Shielded, Flux-Cored Wires


About The Lincoln
Electric Company Lincolns Innershield Wire
Lincoln Electric is the worlds premier Innershield wire by Lincoln Electric is one of the most user-friendly,
manufacturer of welding equipment and convenient, versatile wires on earth. This exceptionally feedable
and consistent wire includes shielding, slagging and deoxidizing
consumables. No company on earth is materials built right in to its inner core. That means no external gas
more focused on the ever-changing bottles or flux on the job! Its a superb choice for bridges, offshore
needs of the welding drilling rigs, and other outside welding applications where winds are
a factor.
professional. Our business is all about
Shielding, slagging and deoxidizing materials are built right in to
helping companies make their welding
the inner core.
operations more effective, more
No need for external gas or flux.
efficient, more profitable.
Many Innershield wires to choose from a wire for every
Lincoln is truly your One Source when
application.
it comes to welding. Were a company
Recommended to be used with constant voltage power
that continually rededicates itself to the sources.
equally important goals of exceptional
One of the most user-friendly welding processes on the market
quality, and exceptional service. Our today.
field support team with hundreds of A great choice for use in moderately windy conditions.
field sales engineers and thousands of
As with all of our wires, Innershields arc characteristics are
knowledgeable and responsive Lincoln outstanding! Thats because we pay more attention to
distributors in countries all over the chemistry, quality of raw materials, and manufacturing
processes than any wire manufacturer in the world!
world is the
largest in the industry. Best of all, Innershield is designed and built by Lincoln Electric.
Our company is all about innovative thinking about listening
Innovative thinking. A quality and and responding to the needs of welding professionals about
service-first attitude. Fresh finding ways to make welding quicker, stronger, and more
approaches to design, manufacturing, efficient.
and packaging. Worldwide strength.
Thats Lincoln Electric.

2 www.linconelectric.com
Advantage Lincoln Contents Page
More precise control. Innershields open arc process allows the oper- Product Introduction . . . 2-3
ator to control the placement of the weld metal and the puddle with
exceptional accuracy.
Electrode Selection
Guide . . . . . . . . . . . . . . . 4-5
More consistent weld deposits. Innershield performs better because
Innershield is built better. The best raw materials. The best manufactur- High Speed Single
ing processes. The best quality control systems. Pass Welding . . . . . . . .6-11
Versatility. No matter what welding positions your job requires, theres General Purpose
an Innershield wire specifically designed to handle it. Weve provided Welding . . . . . . . . . . . .12-17
individual wire descriptions in this brochure that will make it easy for Structural Fabrication
you to choose the right Innershield product for your needs. Welding . . . . . . . . . . . .18-35
Better portability. Because Innershield is completely self-contained Pipe Fabrication . . . . .36-39
with shielding, slagging and deoxidizing materials built right in to the
wires core theres no need for flux feeding systems or gas bottles. Agency Approvals . . . . . .40
That means increased portability of your rigs, and more efficient Storing Inneshield
welding operations.
Electrodes . . . . . . . . . . . .41
Better feedability. Weve coated Innershield wire with specially
designed lubricants that keep the wire feeding beautifully inch after
inch, coil after coil.

Typical Applications
Innershield wire is a great choice for a
wide range of applications, including:
Automotive
Trucks & Trailers
Construction, Farming & Mining
Equipment
Bridges
Buildings
Storage Tanks
Ships & Barges
Offshore Oil Drilling Platforms
Pipelines
Structural Fabrication
Maintenance & Repair

3 www.linconelectric.com
INNERSHIELD WIRE SELECTION GUIDE
Electrode AWS Recommended General Page
Name Classification Positions Description No.

High Speed Single Pass Welding

Innershield NR-1 & NR-5 E70T-3 Flat & Good for high speed flat and horizontal single pass 6-7
Horizontal automatic welding applications, NR-1 is especially
good on circumferential welds with overlapping.
Recommended for materials thicknesses up to
3/16 (4.8 mm).

Innershield NR-131 E70T-10 Flat & For automatic and semiautomatic high speed, single 8-9
Horizontal pass welding on sheet metal with a thickness of .110
(2.8 mm) or more. A solid performer for twin arc welding
applications,especially in flat, horizontal, and automatic
roundabout positions. High deposition rates and travel
speeds.

Innershield NR-152 E71T-14 All Designed for high speed, single pass automatic and 10-11
Positions semiautomatic welding on materials from .030 - 3/16
(0.8 - 4.8 mm). A good choice for galvanized,
specialty zinc-coated, or aluminized carbon steels.

General Purpose Welding

Innershield NR-202 E71T-7 All Good all position welding wire. Can make very small 12-13
Positions welds at high travel speeds. Cost-effective tacking wire
for joining carbon steel.

Innershield NR-211-MP E71T-11 All One of our most popular all-purpose Innershield wires.
Positions Versatile wire suitable for all-position welding of light gauge 14-15
steel or thin plate up to 1/2 (12.7mm). Low spatter and
excellent weld appearance.

Innershield NR-212 E71TG-G All An alternative to NR-211-MP with no restrictions on plate 16-17
Positions thickness. A good choice for general purpose, all-position
welding. Produces smooth welds with excellent
appearance. Designed for single and multiple pass
semiautomatic and automatic welding of mild steel, sheet
metal, plate and coated steel. Low spatter level. Handles
poor fit-up well.

Structural Fabrication Welding

Innershield NR-203MP E71T-8J All Great for all-position (except vertical down) single and 18-19
Positions multiple pass welding with mild steel and some low alloy
steels. Handles poor fit-up on heavy wall tubes and gaps
up to 3/8 (9.5mm) with 1/4 (6.4mm) offset. Excellent
Charpy V-Notch properties.

Innershield NR-203 E71T8-Ni1 All Use for all-positions, including vertical down. For single and 20-21
Nickel (1%) Positions multiple pass welding on mild steel and some low alloy
steels. Performs well in automatic and semiautomatic
applications. Produces a nickel bearing weld deposit with
Charpy V-Notch properties. Can weld gaps up to 3/8
(9.5 mm).

NOTE: All Innershield wires are recommended for use with constant voltage (CV) power sources.

4 www.linconelectric.com
INNERSHIELD WIRE SELECTION GUIDE
Electrode AWS Recommended General Page
Name Classification Positions Description No.

Structural Fabrication Welding (continued)

Innershield NR-203 E61T8-K6 All Produces a nickel bearing weld deposit with good Charpy 22-23
Nickel C Positions V-Notch properties at low temperatures. Designed for single
and multiple pass welding in automatic and semiautomatic
applications.

Innershield NR-203 E71T8-K2 All Similar to NR-203 Nickel C, but with increased strength 24-25
Ni C Plus(1) Positions to join higher strength steels. Handles poor fit-up in the
vertical-up position and welds gaps up to 1/4 (6.4 mm)
with offsets up to 1/4 (6.4 mm).

Innershield NR-232 E71T-8 All Positions, High deposition rate out-of-position welding. Designed 26-27
Except for single and multiple pass welding of 3/16 (4.8mm) and
Vertical heavier mild steel, as well as some low alloy steels.
Down Self-peeling slag. Excellent Charpy V-Notch properties.

Innershield NR-305 E70T-6 Flat & Great for downhand welding applications where high 28-29
Horizontal deposition rates and Charpy V-Notch properties are
desired. Designed for use with mild steel and some low
alloy steels for single and multiple pass, automatic and
semiautomatic welding. Excellent operator appeal.

Innershield NR-311 E70T-7 Flat & Very high deposition rates and fast travel speeds. Welds 30-31
Horizontal thicker mild steels and some low alloy steels. Good bead
shape and easy slag removal.

Innershield NR-311 Ni E70T7-K2 Flat & Similar to NR-311, but with good Charpy V-Notch properties. 32-33
Horizontal High deposition rates. Fast travel speeds. For single and
multiple pass welding.

Innershield NS-3M E70T-4 Flat & Extremely high deposition rate wire designed for automatic 34-35
Horizontal and semiautomatic welding on mild steel and some low
alloy steels. Resistant to cracking on high sulfur steel
and porosity on mildly rusty, oily or dirty plates.
Soft, low penetrating arc.

Pipe Fabrication

Innershield NR-207 & E71T8-K6 Optimum performance on vertical down, hot, fill and cap 36-37
NR-207-H passes on standard cross-country pipelines and arctic
grade pipe. Excellent crack resistance and CTOD and
Charpy V-Notch properties. Recommended API Pipe
Grades X42 through X70.

Innershield NR-208-H E91T8-G Similar to NR-207-H, but with higher strength. Produces 38-39
weld deposits exceeding 80,000 psi yield strength with
excellent low temperature impacts. Recommended for
API Pipe Grade X80.

NOTE: All Innershield wires are recommended for use with constant voltage (CV) power sources.

5 www.linconelectric.com
INNERSHIELD NR -1 & NR-5 AWS A5.20-95: E70T-3

Good for high speed flat and TYPICAL APPLICATIONS WELDING POSITIONS
horizontal single pass automatic
welding applications, NR-1 is NR-1
especially good on circumferential Straight welds.
welds with overlapping. Roundabouts that overlap the start. 1G 2F 2G
Recommended for materials
thicknesses up to 3/16 (4.8 mm). Through welds on material up to 12
gauge. CONFORMANCE
Joints susceptible to slag trapping. AWS A5.20-95: E70T-3
ADVANTAGE LINCOLN ASME SFA-5.20: E70T-3
NR-5
Self-shielded, flux-cored. No need
3-oclock position welds.
for external gas or flux. NOTE:
Can also be used for welds that NR-1 & NR-5 are not recommended
Designed for high travel speeds
require 100% penetration with for welding steel that is more than
up to 170 inches (4.3m) per minute.
copper back-up. 3/16 (4.8mm) thick, or for welding
Our quality driven manufacturing multiple passes.
NR-5 (3/32) diameter can also be
system certified to ISO 9001 and
used in semiautomatic applications.
our exceptionally high grade raw
materials mean every coil of
Innershield delivers great arc
characteristics and superior
feedability.

(1)
MECHANICAL PROPERTIES - As Welded per AWS A5.20

Transverse
Tensile Strength Longitudinal Hardness
psi (MPa) Bend Test Rockwell B

Requirements 70,000 (480) 180 over 3/4 Radius


AWS E70T-3 min. No openings exceeding 1/8

Test Results
72,000 - 79,000
NR-1 Passed 95
(496 - 545)

73,000 - 81,000
NR-5 Passed 99
(503 - 558)
(1) Typical all weld metal.

DIAMETERS / PACKAGING
600 Lb. 600 Lb.
Diameter Speed Feed Speed Feed
Inches (mm) Drum Reel

NR-1
.120 (3.0) EDS12150
5/32 (4.0) EDS12153

NR-5
3/32 (2.4) ED012699 ED012701
.120 (3.0) ED012698

6 www.linconelectric.com
INNERSHIELD NR -1 & NR-5 AWS A5.20-95: E70T-3

TYPICAL OPERATING PROCEDURES


Wire, Polarity Wire Feed Arc Approx. Melt-Off Deposition
Electrical Stickout Speed Voltage Current Rate Rate Efficiency
Wire Weight in/min (m/min) (volts) (amps) lbs/hr (kg/hr) lbs/hr (kg/hr) (%)

.120 NR-1 160 (4.1) 21 500 25.2 (11.4) 22.0 (10.0) 87


DC+ 200 (5.1) 22 610 31.6 (14.3) 28.0 (12.7) 89
1-1/4 (32mm) 240 (6.1) 23 700 37.9 (17.2) 33.0 (15.0) 87
2.63 lbs/1000 295 (7.5) 24 810 46.5 (21.1) 40.0 (18.1) 86
320 (8.1) 25 850 50.5 (23.0) 43.0 (19.5) 85

5/32 NR-1 100 (2.5) 21 630 24.0 (10.9) 19.2 (8.7) 80


DC+ 110 (2.8) 22 680 26.4 (12.1) 21.2 (9.6) 80
1-1/4 (32 mm) 130 (3.3) 23 780 31.2 (14.2) 25.4 (11.5) 81
4.07 lbs/1000 150 (3.8) 24 860 36.0 (16.3) 29.5 (13.4) 82
180 (4.6) 25 960 43.2 (20.1) 35.7 (16.2) 83

3/32 NR-5 100 (2.5) 22 340 9.9 (4.5) 7.8 (3.5) 77


DC+ 150 (3.8) 23 435 14.8 (6.7) 12.3 (5.6) 83
1 (25mm) 200 (5.1) 24 510 19.8 (9.0) 16.9 (7.7) 85
1.60 lbs/1000 250 (6.4) 25 575 24.7 (11.2) 21.4 (9.7) 87

.120 NR-5 130 (3.3) 22 500 18.0 (8.2) 16.7 (7.6) 93


DC+ 165 (4.2) 23 600 23.0 (10.4) 20.9 (9.5) 91
1 (25mm) 205 (6.5) 24 700 28.5 (12.9) 25.6 (11.6) 90
2.46 lbs/1000 255 (6.5) 25 800 35.5 (16.1) 31.5 (14.3) 90

NOTE: Above typical operating procedures are starting points and may be adjusted as required.

(1)
DEPOSIT COMPOSITION
%C %Mn %P %S %Si %Al %Ti

Requirements
AWS E70T-3 Not Required

Test Results .21 1.30 .007 .014 .59 .03 .15

(1) Chemistry of single pass welds is highly dependent upon base metal chemistry and dilution.
Analysis shown are for information purposes only.

This electrode, and others of the same AWS classification, are not required to deposit weld
metal capable of delivering any minimum specified Charpy V-Notch (CVN ) properties. It
should not be used in applications where minimum specified CVN properties are required.
Typical applications where minimum specified CVN properties are required include, but are
not restricted to, bridges, pressure vessels, and buildings in seismic zones. The user of this
product is responsible for determining whether minimum CVN properties are required for
the specific application.

7 www.linconelectric.com
INNERSHIELD NR-131 AWS A5.20-95: E70T-10

For automatic and semiautomatic high TYPICAL APPLICATIONS WELDING POSITIONS


speed, single pass welding on sheet
metal with a thickness of .11 (2.8 mm) Single Arc:
or more. A solid performer for twin arc 1/8 (3.2mm) and 3/16 (4.8mm)
welding applications, especially in flat, fillet welds with travel speeds up to 1G 2F 2G
horizontal, and automatic roundabout 75 in/min (1.9 m/min).
positions. High deposition rates and
travel speeds. CONFORMANCE
Twin Arc:
1/4 (6.4mm) and 5/16 (7.9 mm) AWS A5.20-95: E70T-10
ADVANTAGE LINCOLN fillet welds with travel speeds up to ABS: E70T-10
75 in/min (1.9 m/min).
Self-shielded, flux-cored. No need
An excellent performer on fillets and
for external gas or flux.
laps. NR-131 is also a good choice
Excellent deposition rates. for corner, edge and butt joints.
High travel speeds.
A great choice for welds that join
light steel to heavier members.
Our quality driven manufacturing
system certified to ISO 9001 and
our exceptionally high grade raw
materials mean every coil of
Innershield delivers great arc char-
acteristics and superior feedability.

(1)
MECHANICAL PROPERTIES - As Welded per AWS A5.20

Transverse
Tensile Strength Longitudinal Hardness
psi (MPa) Bend Test Rockwell B

Requirements 70,000 (480) 180 over 3/4 Radius



AWS E70T-10 min. No opening exceeding 1/8

73,000 - 82,000
Test Results Passed 90
(503 - 565)

(1) Typical all weld metal.

DIAMETERS / PACKAGING

600 Lb.
Diameter 50 Lb. Speed Feed
Inches (mm) Coil Reel

3/32 (2.4) EDS12162 ED012163

8 www.linconelectric.com
INNERSHIELD NR-131 AWS A5.20-95: E70T-10

TYPICAL OPERATING PROCEDURES

Wire, Polarity Wire Feed Arc Approx. Melt-Off Deposition


Electrical Stickout Speed Voltage Current Rate Rate Efficiency
Wire Weight in/min (m/min) (volts) (amps) lbs/hr (kg/hr) lbs/hr (kg/hr) (%)

150 (3.8) 25.5 390 14.3 (6.5) 11.6 (5.3) 81


3/32
200 (5.1) 26 490 19.0 (8.6) 15.6 (7.1) 82
Single Arc DC-
250 (6.4) 26.5 570 23.7 (10.8) 19.6 (8.9) 82
1-1/4 (32mm)
350 (8.9) 27 720 33.1 (15.0) 27.6 (12.5) 83
1.580 lbs/1000
425 (10.8) 27.5 810 40.1 (18.2) 33.6 (15.2) 83

3/32 130 (3.3) 25.5 550 24.5 (11.1) 17.9 (8.1) 72


Twinarc DC- 175 (4.4) 26.5 740 33.0 (15.0) 26.4 (12.0) 79
1-1/2 (38mm) 225 (5.7) 27 910 42.5 (19.3) 34.8 (15.8) 81
3.160 lbs/1000 275 (7.0) 28 1030 51.9 (23.5) 42.0 (19.1) 80
(for 2 wires) 325 (8.3) 29 1090 61.4 (27.9) 48.2 (21.9) 78

NOTE: Above typical operating procedures are starting points and may be adjusted as required.

(1)
DEPOSIT COMPOSITION

%C %Mn %P %S %Si %Al

Requirements
AWS E70T-10 .23 .45 .006 .004 .25 1.17

Test Results .252 .53 .008 .009 .21 1.55

(1) Chemistry of single pass welds is highly dependent upon base metal chemistry and dilution.
Analysis shown are for information purposes only.

This electrode, and others of the same AWS classification, are not required to deposit weld
metal capable of delivering any minimum specified Charpy V-Notch (CVN ) properties. It
should not be used in applications where minimum specified CVN properties are required.
Typical applications where minimum specified CVN properties are required include, but are
not restricted to, bridges, pressure vessels, and buildings in seismic zones. The user of this
product is responsible for determining whether minimum CVN properties are required for
the specific application.

9 www.linconelectric.com
INNERSHIELD NR-152 AWS A5.20-95: E71T-14

Designed for high speed, single pass Our quality driven manufacturing WELDING POSITIONS
automatic and semiautomatic welding system certified to ISO 9001 and
on materials from .030 - 3/16 our exceptionally high grade raw
(0.8 - 4.8 mm). A good choice for materials mean every coil of
1G 2F 2G
galvanized, specialty zinc-coated, or Innershield delivers great arc char-
aluminized carbon steels. acteristics and superior feedability.


4G 3G

ADVANTAGE LINCOLN TYPICAL APPLICATIONS


Self-shielded, flux-cored. No need Spot or stitch welds on .030 CONFORMANCE
for external gas or flux. (0.8mm) sheet metal and thicker.
AWS A5.20-95: E71T-14
A great choice for coated steels. Continuous welds on .048 (1.2mm)
uncoated sheet metal at travel
NR-152s exceptionally soft arc speeds of 40-60 in/min
means less burnthrough on thin (1.0-1.5m/min). NOTE:
gauge materials. The preferred drag angle is 15,
Continuous welds on coated steels
Excellent overlapping capabilities on however, NR-152 is capable of
in a travel range of 30-40 in/min
roundabouts. welding at zero drag angle, facilitating
(0.7-1.0 m/min).
easy fixturing in automatic
Fast, sure restarts with no end applications.
clipping necessary.

(1)
MECHANICAL PROPERTIES - As Welded per AWS A5.20

Transverse
Tensile Strength Longitudinal Hardness
psi (MPa) Bend Test Rockwell B

Requirements 72,000 (497) 180 over 3/4 Radius



AWS E71T-14 min. No opening exceeding 1/8

72,000 - 82,000
Test Results Passed 93
(496 - 565)

(1) Typical all weld metal.

DIAMETERS / PACKAGING
500 Lb 600 Lb. 600 Lb.
Diameter 25 Lb. 50 Lb. Speed Feed Speed Feed Speed Feed
Inches (mm) Spool Coil Drum Drum Reel

.045 (1.1) EDS01702


.052 (1.3) EDS01703
.062 (1.6) EDS01021 ED012185 ED024301
.068 (1.7) ED012186 ED019579
5/64 (2.0) ED024265

10 www.linconelectric.com
INNERSHIELD NR-152 AWS A5.20-95: E71T-14

TYPICAL OPERATING PROCEDURES


Wire, Polarity Wire Feed Arc Approx. Melt-Off Deposition
Electrical Stickout Speed Voltage Current Rate Rate Efficiency
Wire Weight in/min (m/min) (volts) (amps) lbs/hr (kg/hr) lbs/hr (kg/hr) (%)

.045 60 (1.5) 15 95 1.3 (0.5) 1.1 (0.5) 84


DC- 90 (2.3) 16 135 2.1 (0.9) 1.8 (0.8) 85
3/8 (10mm) 120 (3.0) 17 160 2.8 (1.2) 2.5 (1.1) 89
.392 lbs/1000 150 (3.8) 18 180 3.4 (1.5) 3.1 (1.4) 91

.052 55 (1.4) 16 100 1.7 (0.7) 1.6 (0.7) 94


DC- 90 (2.3) 17 150 2.6 (1.1) 2.4 (1.1) 92
3/8 (10mm) 110 (2.8) 18 170 3.5 (1.5) 2.9 (1.3) 82
.500 lbs/1000 130 (3.3) 19 190 3.8 (1.7) 3.5 (1.6) 92

.062 30 (0.8) 13 90 1.3 (0.5) 1.2 (0.5) 92


DC- 40 (1.0) 14 115 1.8 (0.8) 1.6 (0.7) 88
3/8 (10mm) 50 (1.3) 15 140 2.2 (0.9) 2.0 (0.9) 90
.736 lbs/1000 70 (1.8) 16.5 185 3.1 (1.4) 2.8 (1.3) 90
110 (2.8) 19 265 4.8 (2.1) 4.4 (2.0) 91

.068 30 (0.8) 13 68 1.6 (0.7) 1.4 (0.6) 87


DC- 40 (1.0) 13.5 95 2.2 (0.9) 1.9 (0.9) 86
1/2 (13mm) 50 (1.3) 14.5 120 2.7 (1.2) 2.4 (1.1) 88
.910 lbs/1000 60 (1.5) 15.5 145 3.3 (1.4) 2.9 (1.3) 87
80 (2.0) 16.5 190 4.4 (1.9) 3.9 (1.8) 88
110 (2.8) 20 240 6.0 (2.7) 5.4 (2.4) 90

5/64 40 (1.0) 16 125 2.8 (1.2) 2.5 (1.1) 89


DC- 70 (1.8) 18 230 4.8 (2.1) 4.3 (1.9) 89
3/4 (19mm) 80 (2.0) 19 260 5.5 (2.4) 4.9 (2.2) 89
1.15 lbs/1000 100 (2.5) 21 310 6.9 (3.1) 6.1 (2.7) 88
125 (3.2) 24 355 8.6 (3.9) 7.6 (3.4) 88

NOTE: Above typical operating procedures are starting points and may be adjusted as required.

(1)
DEPOSIT COMPOSITION

%C %Mn %P %S %Si %Al

Requirements
AWS E71T-14 Not Required

Test Results
.062 (1.6 mm) .30 .99 .013 .007 .24 1.63
.068 (1.7 mm) .30 .91 .009 .011 .25 1.55
5/64 (2.0 mm) .26 .82 .008 .015 .21 1.07

(1) Chemistry of single pass welds is highly dependent upon base metal chemistry and dilution.
Analysis shown are for information purposes only.

This electrode, and others of the same AWS classification, are not required to deposit weld
metal capable of delivering any minimum specified Charpy V-Notch (CVN ) properties. It
should not be used in applications where minimum specified CVN properties are required.
Typical applications where minimum specified CVN properties are required include, but are
not restricted to, bridges, pressure vessels, and buildings in seismic zones. The user of this
product is responsible for determining whether minimum CVN properties are required for
the specific application.

11 www.linconelectric.com
INNERSHIELD NR-202 AWS A5.20-95: E71T-7

Good all position welding wire. Can Our quality driven manufacturing WELDING POSITIONS
make very small welds at high travel system certified to ISO 9001
speeds. Cost-effective tacking wire for and our exceptionally high grade
joining carbon steel. raw materials mean every coil of
1G 2F 2G
Innershield delivers great arc
characteristics and superior
ADVANTAGE LINCOLN feedability.


4G


3G 5G
Self-shielded, flux-cored. No need
for external gas or flux. TYPICAL APPLICATIONS
Produces quality welds in moderate Structural fabrication where no seis- CONFORMANCE
wind conditions with no tenting. mic requirements are present.
AWS A5.20-95: E71T-7
A great wire to use when cost is a Vertical and overhead plate welding. ASME SFA5.20: E71T-7
primary issue, and no impact ABS: E71T-7
properties are required. Fabrication of machinery parts and
hoppers.
Short assembly welds on brackets
and clips.
Roundabout groove welds.

MECHANICAL PROPERTIES (1)


- As Welded per AWS A5.20
Yield Strength Tensile Strength Elongation Hardness
psi (MPa) psi (MPa) (%) Rockwell B

Requirements 58,000 (400) 70,000 (480) 22



AWS E71T-7 min. min. min.

60,000 - 75,000 72,000 - 95,000 22 - 27 87 - 93


Test Results
(414 - 517) (497 - 655)

(1) The strength and elongation properties reported were obtained from a .505 tensile specimen artificially aged
at 220F (104C) for 48 hours, as permitted by AWS A5.20-95. A naturally aged tensile specimen may take
months to achieve the specified properties. See AWS A5.20-95, paragraph A8.3. The time required for the
natural aging of weld deposits is dependent upon ambient conditions, weldment geometry, the metallurgical
structure of the weld deposit and other factors.

DIAMETERS / PACKAGING

Diameter 14 Lb.
Inches (mm) Coil

5/64 (2.0) ED012287

12 www.linconelectric.com
INNERSHIELD NR-202 AWS A5.20-95: E71T-7

TYPICAL OPERATING PROCEDURES

Wire, Polarity Wire Feed Arc Approx. Melt-Off Deposition


Electrical Stickout Speed Voltage Current Rate Rate Efficiency
Wire Weight in/min (m/min) (volts) (amps) lbs/hr (kg/hr) lbs/hr (kg/hr) (%)

50 (1.3) 19.5 150 3.4 (1.5) 2.0 (0.9) 59


5/64 100 (2.5) 20.5 235 6.8 (3.1) 5.1 (2.3) 75
DC- 150 (3.8) 21.5 305 10.2 (4.6) 8.3 (3.8) 81
1 (25mm) 175 (4.4) 22.5 335 11.9 (5.4) 9.9 (4.5) 83
1.09 lbs/1000 200 (5.1) 22.5 365 13.6 (6.2) 11.4 (5.2) 84
230 (5.8) 23.5 400 15.7 (7.1) 13.3 (6.0) 85

NOTE: Above typical operating procedures are starting points and may be adjusted as required.

(1)
DEPOSIT COMPOSITION
%C %Mn %P %S %Si %Al

Requirements
Report 1.75 .03 .03 .60 1.80
AWS E71T-7
Only max. max. max. max. max.

Test Results .19 .72 .007 .003 .20 1.34

(1) Typical all weld metal.

This electrode, and others of the same AWS classification, are not required to deposit weld
metal capable of delivering any minimum specified Charpy V-Notch (CVN ) properties. It
should not be used in applications where minimum specified CVN properties are required.
Typical applications where minimum specified CVN properties are required include, but are
not restricted to, bridges, pressure vessels, and buildings in seismic zones. The user of this
product is responsible for determining whether minimum CVN properties are required for
the specific application.

13 www.linconelectric.com
INNERSHIELD NR-211-MP AWS A5.20-95: E71T-11

One of our most popular all-purpose Produces quality welds in moderate WELDING POSITIONS
Innershield wires. Versatile wire wind conditions with no tenting.
suitable for all-position welding of light Our quality driven manufacturing
gauge steel or thin plate up to 1/2 system certified to ISO 9001 and
(12.7mm). Low spatter and excellent our exceptionally high grade raw 1G 2F 2G

weld appearance. materials mean every coil of


Innershield delivers great arc char-
acteristics and superior feedability.


3G 3G 4G
ADVANTAGE LINCOLN
An extremely popular wire with TYPICAL APPLICATIONS
excellent operator appeal, low CONFORMANCE
spatter, and good weld Single or multiple pass welding.
AWS A5.20-95: E71T-11
appearance. Structural fabrication where no ASME SFA-5.20: E71T-11
NR-211-MP is an extremely versatile seismic requirements are present.
ABS: E71T-11 (.068 - 3/32 only)
wire suitable for all-position Robotic welding applications. CWB: E4801T-11-CH
welding.
A good choice when poor fitup is an
issue. RECOMMENDED
MAXIMUM PLATE THICKNESS
Self-shielded, flux-cored. No need
for external gas or flux. Diameter Max. Plate
Inches (mm) Thickness
.035 & .045 5/16
(0.9 & 1.1) (7.9mm)
.068, 5/64, & 3/32 1/2
(1.7, 2.0 & 2.4) (12.7mm)

MECHANICAL PROPERTIES(1) - As Welded per AWS A5.20

Yield Strength Tensile Strength Elongation Hardness


psi (MPa) psi (MPa) (%) Rockwell B

Requirements 58,000 (400) 70,000 (480) 20



E71T-11 min. min. min.

58,000 - 69,000 72,000 - 95,000 22 - 25 85 - 95


Test Results
(400- 476) (497 - 655)

(1) The strength and elongation properties reported were obtained from a .505 tensile specimen artificially
aged at 220F (104C) for 48 hours, as permitted by AWS A5.20-95. A naturally aged tensile specimen
may take months to achieve the specified properties. See AWS A5.20-95, paragraph A8.3. The time
required for the natural aging of weld deposits is dependent upon ambient conditions, weldment
geometry, the metallurgical structure of the weld deposit and other factors.

DIAMETERS / PACKAGING
300 Lb.
Diameter 1 Lb 10 Lb 14 Lb 25 Lb 50 Lb 50 Lb. Speed-Feed
Inches (mm) Spool Spool Coil Readi-Reel Coil Readi-Reel Reel

.035 (0.9) ED027641 ED016354 ED016364


.045 (1.1) ED016363 ED016365 EDS01040 EDS01522
.068 (1.7) ED012506 ED017827 ED012507
5/64 (2.0) ED012508 ED017828 ED012509
3/32 (2.4) ED013869

14 www.linconelectric.com
INNERSHIELD NR-211-MP AWS A5.20-95: E71T-11

TYPICAL OPERATING PROCEDURES


Wire, Polarity Wire Feed Arc Approx. Melt-Off Deposition
Electrical Stickout Speed Voltage Current Rate Rate Efficiency
Wire Weight in/min (m/min) (volts) (amps) lbs/hr (kg/hr) lbs/hr (kg/hr) (%)

.035 50 (1.3) 14 30 0.8 (0.4) 0.7 (0.3) 81


DC- 70 (1.8) 15 60 1.2 (0.5) 1.0 (0.5) 83
3/8 (10mm) 90 (2.3) 16 90 1.7 (0.8) 1.4 (0.6) 82
.250 lbs/1000 110 (2.8) 16.5 120 2.1 (1.0) 1.7 (0.8) 81

.045 70 (1.8) 15 120 1.6 (0.7) 1.1 (0.5) 69


DC- 90 (2.3) 16 140 2.2 (1.0) 1.7 (0.8) 77
3/8 (10mm) 110 (2.8) 17 160 2.7 (1.2) 2.3 (1.0) 85
.393 lbs/1000 130 (3.3) 18 170 3.2 (1.5) 2.7 (1.2) 84

.068 40 (1.0) 15 125 2.1 (1.0) 1.7 (0.8) 81


DC- 75 (1.9) 18 190 4.0 (1.8) 3.4 (1.5) 85
1/2 - 1 (13 - 25mm) 130 (3.3) 20 270 7.0 (3.2) 6.1 (2.8) 88
.889 lbs/1000 175 (4.4) 23 300 9.4 (4.3) 8.4 (3.8) 89

5/64 50 (1.3) 16 180 3.5 (1.6) 2.9 (1.3) 83


DC- 75 (1.9) 18 235 5.3 (2.4) 4.5 (2.0) 85
1/2 - 1 (13 - 25mm) 120 (3.0) 20 290 8.4 (3.8) 7.4 (3.4) 88
1.17 lbs/1000 160 (4.1) 22 325 11.2 (5.1) 10.0 (4.5) 89

3/32 50 (1.3) 16 245 5.0 (2.3) 4.2 (1.9) 84


DC- 75 (1.9) 19 305 7.5 (3.4) 6.4 (2.9) 85
1/2 - 1 (13 - 25mm) 100 (2.5) 20 365 10.0 (4.5) 8.7 (3.9) 87
1.66 lbs/1000 130 (3.3) 22 400 12.9 (5.9) 11.3 (5.1) 88
NOTE: Above typical operating procedures are starting points and may be adjusted as required.

DEPOSIT COMPOSITION

%C %Mn %P %S %Si %Al

Requirements
Report 1.75 .03 .03 .60 1.8
AWS E71T-11
Only max. max. max. max. max.

Test Results
.068, 5/64, 3/32
.21 - .30 .45 - .65 .005 - .012 .003 - .010 .10 - .25 1.20 - 1.80
(1.7, 2.0, 2.4 mm)
.035 & .045
.21 .50 - .75 .003 - .010 .001 - .008 .10 - .25 1.20 - 1.80
(0.9 & 1.1 mm)

This electrode, and others of the same AWS classification, are not required to deposit weld
metal capable of delivering any minimum specified Charpy V-Notch (CVN ) properties. It
should not be used in applications where minimum specified CVN properties are required.
Typical applications where minimum specified CVN properties are required include, but are
not restricted to, bridges, pressure vessels, and buildings in seismic zones. The user of this
product is responsible for determining whether minimum CVN properties are required for
the specific application.

15 www.linconelectric.com
INNERSHIELD NR-212 AWS A5.29-98: E71TG-G

An alternative to NR-211-MP with no Our quality driven manufacturing WELDING POSITIONS


restrictions on plate thickness. A good system certified to ISO 9001
choice for general purpose, all- and our exceptionally high grade
position welding. Produces smooth raw materials mean every coil of
welds with excellent appearance. Innershield delivers great arc char- 1G 2F 2G
Designed for single and multiple pass acteristics and superior feedability.
semiautomatic and automatic
welding of mild steel, sheet metal,


3G


3G 4G
plate and coated steel. Low spatter TYPICAL APPLICATIONS
level. Handles poor fit-up well. Single or multiple pass, all position
welding on materials .045 (1.1mm) CONFORMANCE
ADVANTAGE LINCOLN and thicker.
AWS A5.29-98: E71TG-G
NR-212 is an extremely versatile Can be used on weathering steels ASME SFA-5.29: E71TG-G
wire. Weld in any position, on a where a color match is important.
wide range of materials including
Structural fabrication where no seis-
coated steel. Not recommended for
mic requirements are present.
vertical up.
A good choice when poor fitup is an Short assembly welds.
issue. Coated steel welds.
Produces quality welds in moderate Robotic applications.
wind conditions with no tenting.
Self-shielded, flux-cored. No need
for external gas or flux.

MECHANICAL PROPERTIES(1) - As Welded per AWS A5.29

Yield Strength Tensile Strength Elongation


psi (MPa) psi (MPa) (%)

Requirements 58,000 (400) 70,000 - 90,000 20


AWS E71TG-G min. (480 - 620) min. min.

Test Results
67,500 (465) 86,200 (594) 27
Typical NR-212

(1) The strength and elongation properties reported were obtained from a .505 tensile
specimen artificially aged at 220F (104C) for 48 hours, as permitted by AWS A5.29-98.
A naturally aged tensile specimen may take months to achieve the specified properties.
The time required for the natural aging of weld deposits is dependent upon ambient
conditions, weldment geometry, the metallurgical structure of the weld deposit and other
factors.

DIAMETERS / PACKAGING
Diameter 10 Lb. 14 Lb. 25 Lb. 50 Lb.
Inches (mm) Spool Coil Readi-Reel Coil

.045 (1.1) ED026090 ED026091


.068 (1.7) ED027803 ED026859
5/64 (2.0) ED027794 ED026860 ED026858

16 www.linconelectric.com
INNERSHIELD NR-212 AWS A5.29-98: E71TG-G

TYPICAL OPERATING PROCEDURES


Wire, Polarity Wire Feed Arc Approx. Melt-Off Deposition
Electrical Stickout Speed Voltage Current Rate Rate Efficiency
Wire Weight in/min (m/min) (volts) (amps) lbs/hr (kg/hr) lbs/hr (kg/hr) (%)

55 (1.4) 14 75 1.3 (0.6) 1.1 (0.5) 84


.045 70 (1.8) 15 90 1.6 (0.7) 1.4 (0.6) 87
DC- 90 (2.3) 16 115 2.1 (0.9) 1.8 (0.8) 85
3/8 (10mm) 110 (2.8) 17 135 2.6 (1.2) 2.2 (1.0) 84
.393 lbs/1000 130 (3.3) 18 155 3.1 (1.4) 2.6 (1.2) 83
150 (3.8) 19 170 3.5 (1.6) 3.0 (1.4) 85

60 (1.5) 16 145 3.1 (1.4) 2.4 (1.1) 77


.068 75 (1.9) 18 180 3.8 (1.7) 3.2 (1.4) 84
DC- 90 (2.3) 19 200 4.5 (2.0) 3.8 (1.7) 84
3/4 (19mm) 120 (3.0) 20 230 6.0 (2.7) 5.2 (2.3) 86
.820 lbs/1000 150 (3.8) 21 255 7.4 (3.3) 6.4 (2.9) 86
175 (4.4) 22 275 8.7 (3.9) 7.5 (3.4) 86

60 (1.5) 16 200 3.8 (1.7) 3.3 (1.5) 86


5/64 75 (1.9) 18 225 4.7 (2.1) 4.1 (1.8) 87
DC- 90 (2.3) 19 245 5.7 (2.6) 5.0 (2.3) 87
3/4 (19mm) 110 (2.8) 20 275 7.1 (3.2) 6.2 (2.8) 87
1.064 lbs/1000 130 (3.3) 21 300 8.3 (3.7) 7.3 (3.3) 87
150 (3.8) 22 325 9.6 (4.3) 8.4 (3.8) 87

NOTE: Above typical operating procedures are starting points and may be adjusted as required.

DEPOSIT COMPOSITION
%C %Mn* %P %S %Si* %Al* %Ni* %Cr* %Mo* %V*

Requirements
Report 1.75 .03 .03 .80 1.8 .50 .30 .20 .10
AWS E71TG-G
Only min. max. max. min. min. min. min. min. min.

Test Results .10 .97 .007 .003 .31 1.52 1.10 .03 .01 <.01

NOTE: In order to meet the alloy requirements of the G group, the weld deposit needs to have
the minimum, as specified in the table, of only one of the elements marked with an asterisk.

This electrode, and others of the same AWS classification, are not required to deposit weld
metal capable of delivering any minimum specified Charpy V-Notch (CVN ) properties. It
should not be used in applications where minimum specified CVN properties are required.
Typical applications where minimum specified CVN properties are required include, but are
not restricted to, bridges, pressure vessels, and buildings in seismic zones. The user of this
product is responsible for determining whether minimum CVN properties are required for
the specific application.

17 www.linconelectric.com
INNERSHIELD NR-203MP AWS A5:20-95: E71T-8J

Great for all-position (except vertical Our quality driven manufacturing WELDING POSITIONS
down) single and multiple pass system certified to ISO 9001 and
welding with mild steel and some low our exceptionally high grade raw
alloy steels. Handles poor fit-up on materials mean every coil of
1G 2F 2G
heavy wall tubes and gaps up to 3/8 Innershield delivers great arc char-
(9.5mm) with 1/4 (6.4mm) offset. acteristics and superior feedability.
Excellent Charpy V-Notch properties.


TYPICAL APPLICATIONS 3G 3G 4G

ADVANTAGE LINCOLN General plate fabrication, including


Fast freezing slag system facilitates bridge construction, hull plate and
all position welding, including stiffener welding on ships and


5G
vertical down. barges.
Handles poor fit-up on heavy wall Fabrication of storage tanks. CONFORMANCE
tubes. Gaps up to 3/8 (9.5 mm)
Structural fabrication, including AWS A5.20-95: E71T-8J
with 1/4 (6.35 mm) offset are
applications involving seismic ASME SFA-5.20: E71T-8J
weldable.
requirements. ABS: 3SA-3YSAH15
Makes root beads in groove welds Lloyds: 3S-3YH15
without backup bars. DNV: III YMSH15
Self-shielded, flux-cored. No need GL: 3YSH15
for external gas or flux. BV: SA3YMH
Produces quality welds in moderate NK: KSW53NH10
wind conditions with no tenting.

MECHANICAL PROPERTIES(1) - As Welded per AWS A5.20

Charpy V-Notch
Yield Strength Tensile Strength Elongation ft-lbs (Joules) Hardness
psi (MPa) psi (MPa) (%) @ -20F (-29C) @-40F (-40C) Rockwell B
Requirements 58,000 (400) 70,000 (480) 22 Not 20 (27)

AWS E71T-8 min. min. min. Specified min.

58,000 (400) 70,000 (480) 22 Not 20 (27)


AWS E71T-8J
min. min. min. Specified min.

60,000 - 65,000 72,000 - 80,000 50 - 200 66


Test Results 28 - 31 82 - 92
(414 - 448) (496 - 552) (68 - 271) (90)

(1)
The strength and elongation properties reported were obtained from a .505 tensile specimen artificially aged at 220F (104C)
for 48 hours, as permitted by AWS A5.20-95. A naturally aged tensile specimen may take months to achieve the specified
properties. See AWS A5.20-95, paragraph A8.3. The time required for the natural aging of weld deposits is dependent upon
ambient conditions, weldment geometry, the metallurgical structure of the weld deposit and other factors.

DIAMETERS / PACKAGING
Diameter (1) 14 Lb 22 Lb
mm (Inches) Coil Readi-Reel

1.7 (.068) ED025040


2.0 (5/64) ED021604

(1)
Manufactured in metric diameter, U.S. customary
size approximate.

18 www.linconelectric.com
INNERSHIELD NR-203MP AWS A5:20-95: E71T-8J

TYPICAL OPERATING PROCEDURES

Wire, Polarity Wire Feed Arc Approx. Melt-Off Deposition


Electrical Stickout Speed Voltage Current Rate Rate Efficiency
Wire Weight in/min (m/min) (volts) (amps) lbs/hr (kg/hr) lbs/hr (kg/hr) (%)

70 (1.8) 16 145 3.3 (1.5) 2.3 (1.0) 69


.068
90 (2.3) 18 180 4.2 (1.9) 3.2 (1.5) 76
DC-
120 (3.0) 20 225 5.6 (2.5) 4.3 (2.0) 76
3/4 (19mm)
140 (3.5) 21 255 6.4 (2.9) 4.8 (2.2) 75
.782 lbs/1000
150 (3.8) 23 265 6.8 (3.1) 5.1 (2.3) 75

50 (1.3) 16 130 3.1 (1.4) 1.9 (0.9) 61


5/64 70 (1.8) 18 180 4.3 (2.0) 2.9 (1.3) 67
DC- 90 (2.3) 19 220 5.6 (2.5) 4.2 (1.9) 75
3/4 (19mm) 110 (2.8) 20 260 6.8 (3.1) 5.3 (2.4) 77
1.032 lbs/1000 120 (3.0) 21 280 7.4 (3.4) 5.9 (2.7) 79
140 (3.6) 22 310 8.7 (3.9) 6.8 (3.1) 78

NOTE: Above typical operating procedures are starting points and may be adjusted as required.

DEPOSIT COMPOSITION
%C %Mn %P %S %Si %Al

Requirements
Report 1.75 .03 .03 .60 1.8
AWS E71T-8J
only max. max. max. max. max.

Test Results .075 1.45 <.010 <.003 .33 .80

RADIOGRAPHIC GUIDELINES
The opacity of NR-203MP slag to x-ray is such that slag inclusions will normally appear lighter than the weld.
Voids will normally appear darker than the weld. When using gamma-radiography, slag inclusions and voids will
normally appear darker than the weld. Improved x-ray film readability usually can be obtained by slight over-
exposure at an excitation potential consistent with good x-ray practice, but not over 240 KV. For detailed
information on welding techniques, procedure adjustments, and their effects on weld appearance and quality,
request publication C3.2400 Innershield Electrode - Semiautomatic Production Welding Guide.

19 www.linconelectric.com
INNERSHIELD NR-203 NICKEL (1%) AWS A5.29-98: E71T8-Ni1

Use for all-positions, including vertical Self-shielded, flux-cored. No need WELDING POSITIONS
down. For single and multiple pass for external gas or flux.
welding on mild steel and some low
Produces quality welds in moderate
alloy steels. Performs well in
wind conditions with no tenting. 1G 2F 2G
automatic and semiautomatic
applications. Produces a nickel Our quality driven manufacturing
bearing weld deposit with Charpy system certified to ISO 9001
V-Notch properties. Can weld gaps up and our exceptionally high grade


4G


3G 3G
to 3/8 (9.5 mm). raw materials mean every coil of
Innershield delivers great arc
ADVANTAGE LINCOLN characteristics and superior


feedability. 5G
A good choice for use on weathering
steels where color match is CONFORMANCE
important. TYPICAL APPLICATIONS
AWS A5.29-98: E71T8-Ni1
Handles poor fit-up in the vertical up Roundabout groove welds on heavy ASME SFA-5.29: E71T8-Ni1
position. Welds gaps up to 3/8 wall tubular construction ABS: 3SA-3YSA
(9.5mm). Lloyds: 3S-3YSH15
Offshore welding applications.
DNV: III YMSH15
Produces a nickel alloyed weld
Bridges and other outdoor structural
deposit (.80 - 1.10%).
components with weathering steel.
Makes root beads in groove welds
without backup bars.

MECHANICAL PROPERTIES(1) - As Welded per AWS A5.29

Charpy V-Notch
Yield Strength Tensile Strength Elongation ft-lbs (Joules)
psi (MPa) psi (MPa) (%) @ -20F (-29C) @ -40F (-40C)

Requirements 58,000 min. 70,000 - 90,000 20 20 (27) Not


AWS E71T8-Ni1 (400) (483 - 620) min. min. Specified

66,000 - 75,000 72,000 - 85,000 20 - 30 24 - 111 42 - 87


Test Results
(455 - 517) (496 - 585) (33 - 151) (57 - 118)

Stress-Relieved 61,000 - 70,000 67,000 - 74,000 70 - 99


27 - 30
1 Hr @ 1150F (621C) (421 - 483) (462 - 510) (95 - 134)
(1) The strength and elongation properties reported were obtained from a .505 tensile specimen artificially aged at 220F (104C)
for 48 hours, as permitted by AWS A5.29-98. A naturally aged tensile specimen may take months to achieve the specified
properties. The time required for the natural aging of weld deposits is dependent upon ambient conditions, weldment geometry,
the metallurgical structure of the weld deposit and other factors.

DIAMETERS / PACKAGING
Diameter 14 Lb 50 Lb
Inches (mm) Coil Coil

5/64 (2.0) ED012385 ED012386


3/32 (2.4) ED012383 ED012384

20 www.linconelectric.com
INNERSHIELD NR-203 NICKEL (1%) AWS A5.29-98: E71T8-Ni1

TYPICAL OPERATING PROCEDURES


Wire, Polarity Wire Feed Arc Approx. Melt-Off Deposition
Electrical Stickout Speed Voltage Current Rate Rate Efficiency
Wire Weight in/min (m/min) (volts) (amps) lbs/hr (kg/hr) lbs/hr (kg/hr) (%)

50 (1.3) 16.5 145 3.0 (1.4) 2.3 (1.0) 76


5/64 70 (1.8) 18.5 195 4.3 (2.0) 3.3 (1.5) 76
DC- 90 (2.3) 19.5 240 5.5 (2.5) 4.3 (2.0) 78
3/4 (19mm) 110 (2.8) 20.5 275 6.7 (3.0) 5.3 (2.4) 79
1.015 lbs/1000 120 (3.1) 21.5 290 7.3 (3.3) 5.8 (2.6) 79
140 (3.6) 22.5 310 8.5 (3.9) 6.9 (3.1) 81

50 (1.3) 18.5 215 4.6 (2.1) 3.6 (1.6) 78


3/32
70 (1.8) 19.5 260 6.4 (2.9) 5.1 (2.3) 79
DC-
95 (2.4) 21.5 315 8.7 (3.9) 7.0 (3.2) 80
3/4 (19mm)
110 (2.8) 22.5 345 10.0 (4.5) 8.1 (3.7) 81
1.518 lbs/1000
130 (3.3) 23.5 385 11.8 (5.4) 9.6 (4.4) 81

NOTE: Above typical operating procedures are starting points and may be adjusted as required.

DEPOSIT COMPOSITION
%C %Mn %Ni %P %S %Si %Al %V %Cr %Mo

Requirements
0.12 1.50 .80 - 0.03 0.03 0.80 1.8 0.05 0.15 0.35
AWS E71T8-Ni1
max. max. 1.10 max. max. max. max. max. max. max.

Test Results .081 1.17 .96 .006 .003 .27 .88 <.01 .03 .02

This electrode has been tested in accordance with FEMA 353 - Recommended
Specifications and Quality Assurance Guidelines for Steel Moment-Frame Construction for
Seismic Applications and is capable of depositing weld metal that delivers minimum CVN
properties of 40 ft-lbs. at 70F (95 Joules at 21C)at low and high heat input levels. As
required by the AWS classification, it meets a minimum CVN of 20 ft-lbs. at -20F (27 Joules
at -29C), when tested in accordance with AWS A5.20. This electrode will also deposit weld
metal that will meet the requirements for H16 as tested according to AWS A4.3
FEMA 353 test certificates are available upon request.

RADIOGRAPHIC GUIDELINES
The opacity of NR-203 Nickel (1%) slag to x-ray is such that slag inclusions will normally appear lighter than the weld. Voids will normally
appear darker than the weld. When using gamma-radiography, slag inclusions and voids will normally appear darker than the weld.
Improved x-ray film readability usually can be obtained by slight over-exposure at an excitation potential consistent with good x-ray
practice, but not over 240 KV. For detailed information on welding techniques, procedure adjustments, and their effects on weld appear-
ance and quality, request publication C3.2400 Innershield Electrode - Semiautomatic Production Welding Guide.

21 www.linconelectric.com
INNERSHIELD NR-203 NICKEL C AWS A5.29-98: E61T8-K6

Produces a nickel bearing weld TYPICAL APPLICATIONS WELDING POSITIONS


deposit with good Charpy V-Notch
properties at low temperatures. Applications requiring good CTOD
Designed for single and multiple pass properties and Charpy V-Notch
welding in automatic and properties. 1G 2F 2G

semiautomatic applications. Offshore welding applications.


Storage, pipe, transportation and
ADVANTAGE LINCOLN other applications involving low 4G


3G 3G
temperature alloys.
Produces a nickel alloyed weld
deposit (0.40 - 0.8%). Roundabout groove welds on heavy
wall tubular construction.


Self-shielded, flux-cored. No need 5G

for external gas or flux. General plate fabrication including


bridges. CONFORMANCE
Produces quality welds in moderate
wind conditions with no tenting. Hull plate and stiffener welding on AWS A5.29-98: E61T8-K6
ships and barges. ASME SFA5.29: E61T8-K6
Our quality driven manufacturing ABS: 3SA
system certified to ISO 9001 Lloyds: 3SH15
and our exceptionally high grade DNV: III MS(H15)
raw materials mean every coil of
Innershield delivers great arc
characteristics and superior
feedability.

MECHANICAL PROPERTIES(1) - As Welded per AWS A5.29

Charpy V-Notch
Yield Strength Tensile Strength Elongation ft-lbs (Joules) Hardness
psi (MPa) psi (MPa) (%) @ -20F (-29C) @ -40F (-40C) Rockwell B

Requirements 50,000 min. 60,000 - 80,000 22 20 (27) Not



AWS E61T8-K6 (345) (414 - 551) min. min. Required

58,000 71,000 80 - 264 50 - 175


Test Results 29 80
(400) (489) (108 - 358) (68 - 237)

(1) The strength and elongation properties reported were obtained from a .505 tensile specimen artificially aged at 220F (104C) for 48 hours,
as permitted by AWS A5.29-98. A naturally aged tensile specimen may take months to achieve the specified properties. The time required
for the natural aging of weld deposits is dependent upon ambient conditions, weldment geometry, the metallurgical structure of the weld
deposit and other factors.

DIAMETERS / PACKAGING
Diameter 14 Lb
Inches (mm) Coil

5/64 (2.0) ED012310

22 www.linconelectric.com
INNERSHIELD NR-203 NICKEL C AWS A5.29-98: E61T8-K6

TYPICAL OPERATING PROCEDURES


Wire, Polarity Wire Feed Arc Approx. Melt-Off Deposition
Electrical Stickout Speed Voltage Current Rate Rate Efficiency
Wire Weight in/min (m/min) (volts) (amps) lbs/hr (kg/hr) lbs/hr (kg/hr) (%)

5/64 50 (1.3) 16.5 120 3.2 (1.5) 2.1 (1.0) 66


DC- 70 (1.8) 17.5 170 4.5 (2.0) 3.2 (1.5) 71
3/4 (19mm) 90 (2.3) 19.5 210 5.8 (2.6) 4.3 (2.0) 74
1.062 lbs/1000 110 (2.8) 20.5 240 7.0 (3.2) 5.4 (2.4) 77

NOTE: Above typical operating procedures are starting points and may be adjusted as required.

DEPOSIT COMPOSITION
%C %Mn %P %S %Si %Al %V %Ni %Cr %Mo

Requirements
0.15 .50 - .03 .03 .80 1.8 .05 .40 - .15 .15
AWS E61T8-K6
max. 1.50 max. max. max. max. max. 1.00 max. max.

Test Results .058 .83 .004 <.003 .05 .73 <.01 .57 .08 <.01

RADIOGRAPHIC GUIDELINES
The opacity of NR-203 Nickel C slag to x-ray is such that slag inclusions will normally appear lighter than the weld.
Voids will normally appear darker than the weld. When using gamma-radiography, slag inclusions and voids will nor-
mally appear darker than the weld. Improved x-ray film readability usually can be obtained by slight over-exposure
at an excitation potential consistent with good x-ray practice, but not over 240 KV. For detailed information on
welding techniques, procedure adjustments, and their effects on weld appearance and quality, request publication
C3.2400 Innershield Electrode - Semiautomatic Production Welding Guide.

23 www.linconelectric.com
INNERSHIELD NR-203 Ni C Plus AWS A5.29-98: E71T8-K2

Similar to NR-203 Nickel C, but with Our quality driven manufacturing WELDING POSITIONS
increased strength to join higher system certified to ISO 9001
strength steels. Handles poor fit-up and our exceptionally high grade
in the vertical-up position and welds raw materials mean every coil of
1G 2F 2G
gaps up to 1/4 (6.4 mm) with offsets Innershield delivers great arc
up to 1/4 (6.4 mm). characteristics and superior
feedability.


4G


3G 3G
ADVANTAGE LINCOLN
TYPICAL APPLICATIONS
A good choice for welding
weathering steels. Applications requiring good Charpy


V-Notch properties. 5G
Handles poor fit-up in the vertical up
position. Successfully welds gaps Roundabout groove welds on heavy
up to 1/4 with offsets up to 1/4. wall tubular construction. CONFORMANCE
Produces a nickel alloyed weld Offshore welding applications. AWS A5.29-98: E71T8-K2
deposit (1.1 - 1.4%). ASME A5.29: E71T8-K2
Structural fabrication, including
Self-shielded, flux-cored. No need those with seismic requirements(1).
for external gas or flux.
General plate fabrication including
Produces quality welds in moderate bridges.
wind conditions with no tenting.
Hull plate and stiffener welding on
ships and barges.

MECHANICAL PROPERTIES(1) - As Welded per AWS A5.29

Charpy V-Notch
Yield Strength Tensile Strength Elongation ft-lbs (Joules)
psi (MPa) psi (MPa) (%) @ -20F (-29C)

Requirements 58,000 min. 70,000 - 90,000 20 20 min.


AWS E71T8-K2 (400) (490 - 620) min. (27)

61,000 - 72,000 72,000 - 84,000 102 - 212


Test Results 22 - 30
(421 - 496) (496 - 579) (137 - 285)

(1) The strength and elongation properties reported were obtained from a .505 tensile specimen artificially
aged at 220F (104C) for 48 hours, as permitted by AWS A5.29-98. A naturally aged tensile specimen
may take months to achieve the specified properties. The time required for the natural aging of weld
deposits is dependent upon ambient conditions, weldment geometry, the metallurgical structure of the
weld deposit and other factors.

DIAMETERS / PACKAGING

Diameter 14 Lb.
Inches (mm) Coil

5/64 (2.0) ED020227

24 www.linconelectric.com
INNERSHIELD NR-203 Ni C Plus AWS A5.29-98: E71T8-K2

TYPICAL OPERATING PROCEDURES


Wire, Polarity Wire Feed Arc Approx. Melt-Off Deposition
Electrical Stickout Speed Voltage Current Rate Rate Efficiency
Wire Weight in/min (m/min) (volts) (amps) lbs/hr (kg/hr) lbs/hr (kg/hr) (%)

5/64 50 (1.3) 16.5 115 3.2 (1.5) 2.3 (1.0) 72


DC- 70 (1.8) 17.5 170 4.5 (2.0) 3.3 (1.5) 73
3/4 (19mm) 90 (2.3) 19.5 210 5.8 (2.6) 4.4 (2.0) 76
1.091 lbs/1000 110 (2.8) 20.5 245 7.0 (3.2) 5.5 (2.5) 79

NOTE: Above typical operating procedures are starting points and may be adjusted as required.

DEPOSIT COMPOSITION
%C %Mn %P %S %Si %Al %V %Ni %Cr %Mo

Requirements
0.15 0.5 - 0.03 0.03 0.80 1.8 0.05 1.00 - 0.15 0.35
AWS E71T8-K2
max. 1.75 max. max. max. max. max. 2.00 max. max.

Test Results .05 .85 .009 <.003 .07 1.08 <.01 1.27 .14 .02

RADIOGRAPHIC GUIDELINES
The opacity of NR-203 Ni C Plus slag to x-ray is such that slag inclusions will normally appear lighter than the
weld. Voids will normally appear darker than the weld. When using gamma-radiography, slag inclusions and
voids will normally appear darker than the weld. Improved x-ray film readability usually can be obtained by
slight over-exposure at an excitation potential consistent with good x-ray practice, but not over 240 KV. For
detailed information on welding techniques, procedure adjustments, and their effects on weld appearance
and quality, request publication C3.2400 Innershield Electrode - Semiautomatic Production Welding Guide.

25 www.linconelectric.com
INNERSHIELD NR-232 AWS A5.20-95: E71T-8

High deposition rate out-of-position Our quality driven manufacturing WELDING POSITIONS
welding. Designed for single and system certified to ISO 9001
multiple pass welding of 3/16 and our exceptionally high grade
(4.8mm) and heavier mild steel, as raw materials mean every coil of
well as some low alloy steels. Innershield delivers great arc 1G 2F 2G
Self-peeling slag. Excellent Charpy characteristics and superior
V-Notch properties. feedability.


4G


3G 5G
ADVANTAGE LINCOLN TYPICAL APPLICATIONS
CONFORMANCE
Fast freezing slag system supports Structural fabrication, including AWS A5.20-95: E71T-8
high deposition rates on those subject to seismic require- ASME SFA5.20: E71T-8
out-of-position welding. ments(1). ABS: 3SA-3YSAH
Self peeling slag. General plate fabrication including Lloyds: 3S-3YSH15
bridges. DNV: III YMSH15
Self-shielded, flux-cored. No need
G.L.: 3YSH10
for external gas or flux. Hull plate and stiffener welding on N.K.: KSW 53NH10
ships and barges. MIL Spec: MIL-71T-8AS
Produces quality welds in moderate
wind conditions with no tenting. Machinery parts, tanks, hoppers, B.V.: SA3YMH
racks and scaffolding.

MECHANICAL PROPERTIES(1) - As Welded per AWS A5.20

Charpy V-Notch
Yield Strength Tensile Strength Elongation ft-lbs (Joules) Hardness
psi (MPa) psi (MPa) (%) @ -20F (-29C) Rockwell B

Requirements 58,000 (400) 70,000 (480) 22 20



AWS E71T-8 min. min. min. (27)

60,000 - 74,000 72,000 - 87,000 22 - 30 20 - 69 88-90


Test Results
(414 - 510) (496 - 600) (27 - 94)

(1) The strength and elongation properties reported were obtained from a .505 tensile specimen artificially aged at 220F
(104C) for 48 hours, as permitted by AWS A5.20-95. A naturally aged tensile specimen may take months to achieve the
specified properties. See AWS A5.20-95, paragraph A8.3. The time required for the natural aging of weld deposits is
dependent upon ambient conditions, weldment geometry, the metallurgical structure of the weld deposit and other factors.

DIAMETERS / PACKAGING
Seismic Welding Products
Hermetically Sealed Package T2 Lot Controlled and Tested
33 Lb Steel 33 Lb Steel
Diameter 13.5 Lb 22 Lb 50 Lb 13.5 Lb Coil Spool 13.5 Lb Coil Spool
Inches (mm) Coil Readi-Reel Coil (Sealed Pail) (Foil Bag) (Sealed Pail) (Foil Bag)

.068 (1.7) ED012518 ED012519 ED030003 ED030371 ED030381 ED030382


.072 (1.8) ED012522 ED012521 ED012523 ED030232 ED030372 ED030383 ED030384
5/64 (2.0) ED012525 ED012524 ED012526

26 www.linconelectric.com
INNERSHIELD NR-232 AWS A5.20-95: E71T-8

TYPICAL OPERATING PROCEDURES


Wire, Polarity Wire Feed Arc Approx. Melt-Off Deposition
Electrical Stickout Speed Voltage Current Rate Rate Efficiency
Wire Weight in/min (m/min) (volts) (amps) lbs/hr (kg/hr) lbs/hr (kg/hr) (%)

110 (2.7) 19 195 5.0 (2.3) 3.9 (1.8) 78


.068 130 (3.3) 20 225 6.2 (2.8) 4.6 (2.0) 74
DC- 150 (3.8) 20 250 7.1 (3.2) 5.3 (2.4) 75
1/2-1 (12-25mm) 170 (4.3) 21 270 7.8 (3.5) 6.1 (2.8) 78
.755 lbs/1000 195 (5.0) 23.5 300 9.4 (4.3) 7.0 (3.2) 74
250 (6.4) 23.5 350 11.8 (5.4) 9.0 (4.0) 76
320 (7.4) 26 400 15.2 (6.9) 11.4 (5.2) 75

80 (2.0) 17 130 4.0 (1.8) 3.3 (1.5) 83


.072 140 (3.6) 19.5 225 6.8 (3.1) 5.5 (2.5) 81
DC- 155 (3.9) 20.5 240 7.2 (3.3) 6.0 (2.7) 83
1/2-1 (12-25mm) 170 (4.3) 21.5 255 8.0 (3.6) 6.5 (2.9) 81
.778 lbs/1000 250 (6.4) 23 315 11.7 (5.3) 9.6 (4.3) 82
290 (7.4) 24 350 13.6 (6.2) 11.0 (5.0) 81

5/64 60 (1.5) 16.5 145 3.7 (1.7) 2.7 (1.2) 73


115 (2.9) 19.5 260 7.0 (3.2) 5.5 (2.5) 78
DC-
120 (3.0) 19.5 270 7.3 (3.3) 5.7 (2.6) 78
1/2-1 (12-25mm)
130 (3.3) 20.5 285 7.8 (3.5) 6.2 (2.8) 79
1.000 lbs/1000
180 (4.6) 22.5 365 10.9 (5.0) 8.7 (3.9) 80

NOTE: Above typical operating procedures are starting points and may be adjusted as required.

DEPOSIT COMPOSITION
%C %Mn %P %S %Si %Al

Requirements
Report 1.75 .03 .03 .60 1.8
AWS E71T-8 only max. max. max. max. max.

Test Results .17 .72 .007 .003 .31 .71

This electrode has been tested in accordance with FEMA 353 - Recommended
Specifications and Quality Assurance Guidelines for Steel Moment-Frame Construction for
Seismic Applications and is capable of depositing weld metal that delivers minimum CVN
properties of 40 ft-lbs. at 70F (95 Joules at 21C)at low and high heat input levels. As
required by the AWS classification, it meets a minimum CVN of 20 ft-lbs. at -20F (27 Joules
at -29C), when tested in accordance with AWS A5.20. This electrode will also deposit weld
metal that will meet the requirements for H16 as tested according to AWS A4.3
FEMA 353 test certificates are available upon request.

27 www.linconelectric.com
INNERSHIELD NR-305 AWS A5.20-95: E70T-6

Great for downhand welding applica- Our quality driven manufacturing WELDING POSITIONS
tions where high deposition rates and system certified to ISO 9001 and
Charpy V-Notch properties are our exceptionally high grade raw
desired. Designed for use with mild materials mean every coil of
steel and some low alloy steels for Innershield delivers great arc char- 1G 2F 2G
single and multiple pass, automatic acteristics and superior feedability.
and semiautomatic welding. Excellent
operator appeal. CONFORMANCE
TYPICAL APPLICATIONS AWS A5.20-95: E70T-6
ASME SFA5.20: E70T-6
ADVANTAGE LINCOLN Structural fabrication, including ABS: 2SA, 2YSA
A great choice when high those subject to seismic require- DNV: II YMS
deposition rates and good ments(1). GL: 2YS
penetration are desired. BV: SA2YM
General plate fabrication including
Low spatter. bridges and offshore rigs.
Welds well on lightly rusted or Shipyards.
primed plate. Stiffener welding on ships and
Self-shielded, flux-cored. No need barges.
for external gas or flux. Welding over tack welds made with
Produces quality welds in moderate stick electrodes.
wind conditions with no tenting.

MECHANICAL PROPERTIES(1) - As Welded per AWS A5.20


Charpy V-Notch
Yield Strength Tensile Strength Elongation ft-lbs (Joules)
psi (MPa) psi (MPa) (%) @ 0F (-18C) @ -20F (-29C)

Requirements 58,000 (400) 70,000 (480) 22 20 (27)



AWS E70T-6 min. min. min. min.

Test Results 62,000 - 76,000 72,000 - 89,000 23 - 32 21 - 54 21 - 35


As Welded (427 - 524) (496 - 614) (28 - 73) (28 - 47)

Stress Relieved 54,000 - 62,000 71,000 - 84,000 28 - 37 34 - 60 20 - 56


1 Hr @ 1150F (621C) (372 - 427) (489 - 579) (46 - 81) (27 - 76)

(1) The strength and elongation properties reported were obtained from a .505 tensile specimen artificially aged at 220F
(104C) for 48 hours, as permitted by AWS A5.20-95. A naturally aged tensile specimen may take months to achieve the
specified properties. See AWS A5.20-95, paragraph A8.3. The time required for the natural aging of weld deposits is
dependent upon ambient conditions, weldment geometry, the metallurgical structure of the weld deposit and other factors.

DIAMETERS / PACKAGING
Seismic Welding Products
Hermetically Sealed Package T2 lot Controlled and Tested
Diameter 22 Lb 50 Lb 22 Lb Readi-Reel 50 Lb Coil 22 Lb Readi-Reel 50 Lb Coil
Inches (mm) Readi-Reel Coil (Foil Bag) (Foil Bag) (Foil Bag) (Foil Bag)

5/64 (2.0) ED028696 (2) (2) (2) (2)


3/32 (2.4) ED012593 ED030373 ED030005 ED030385 ED030386

(2) 5/64 in. NR305 is not recommended for seismic welding applications.

28 www.linconelectric.com
INNERSHIELD NR-305 AWS A5.20-95: E70T-6

TYPICAL OPERATING PROCEDURES


Wire, Polarity Wire Feed Arc Approx. Melt-Off Deposition
Electrical Stickout Speed Voltage Current Rate Rate Efficiency
Wire Weight in/min (m/min) (volts) (amps) lbs/hr (kg/hr) lbs/hr (kg/hr) (%)

5/64 200 (5.1) 22 385 12.8 (5.8) 10.0 (4.5) 78


DC+ 250 (6.4) 25 430 16.0 (7.2) 13.0 (5.8) 81
7/8 to 1-3/4 350 (8.8) 30 450 22.5 (10.2) 18.8 (8.5) 83
(22- 44 mm) 450 (11.4) 32 545 28.9 (13.1) 24.5 (11.1) 84
1.07 lbs/1000

3/32 160 (4.1) 22 330 13.3 (6.0) 11.0 (5.0) 82


DC+ 240 (6.1) 25 425 20.0 (9.1) 16.7 (7.6) 83
2 (51mm) 300 (7.6) 28 475 25.0 (11.3) 21.0 (9.5) 84
1.39 lbs/1000 400 (10.2) 34 525 33.4 (15.2) 28.0 (12.7) 83

NOTE: Above typical operating procedures are starting points and may be adjusted as required.

DEPOSIT COMPOSITION
%C %Mn %P %S %Si %Al

Requirements
Report 1.75 .03 .03 .60 1.80
AWS E70T-6 Only max. max. max. max. max.

Test Results
3/32 (2.0 mm) .08 1.26 .012 .005 .23 1.19
5/64 (2.4 mm) .08 .60 .006 .006 .20 .73

This electrode has been tested in accordance with FEMA 353 - Recommended
Specifications and Quality Assurance Guidelines for Steel Moment-Frame Construction for
Seismic Applications and is capable of depositing weld metal that delivers minimum CVN
properties of 40 ft-lbs. at 70F (95 Joules at 21C)at low and high heat input levels. As
required by the AWS classification, it meets a minimum CVN of 20 ft-lbs. at -20F (27 Joules
at -29C), when tested in accordance with AWS A5.20. This electrode will also deposit weld
metal that will meet the requirements for H16 as tested according to AWS A4.3
FEMA 353 test certificates are available upon request.

29 www.linconelectric.com
INNERSHIELD NR-311 AWS A5.20-95: E70T-7

Very high deposition rates and fast Our quality driven manufacturing WELDING POSITIONS
travel speeds. Welds thicker mild system certified to ISO 9001
steels and some low alloy steels. and our exceptionally high grade
Good bead shape and easy slag raw materials mean every coil of
removal. Innershield delivers great arc 1G 2F 2G

characteristics and superior


feedability.
ADVANTAGE LINCOLN
CONFORMANCE
High deposition rates and fast travel
TYPICAL APPLICATIONS AWS A5.20-95: E70T-7
speeds.
ASME SFA-5.20: E70T-7
Smooth operation. Good bead Fillet, lap and butt welds on 1/8 ABS: E70T-7 per AWS A5.20-95
shape. (3.2mm) and thicker steels.
Deep penetration. Horizontal butt welds such as
Easy slag removal in deep grooves. column-to-column structural con-
Resists weld cracking on high sulfur nections not subject to seismic
steels. requirements.

Self-shielded, flux-cored. No need General fabrication and assembly


for external gas or flux. welding.
Produces quality welds in moderate
wind conditions with no tenting.

MECHANICAL PROPERTIES(1) - As Welded per AWS A5.20

Yield Strength Tensile Strength Elongation Hardness


Condition psi (MPa) psi (MPa) (%) Rockwell B

Requirements 58,000 (400) 70,000 (480) 22



AWS E70T-7 min. min. min.

60,000 - 66,000 82,000 - 90,000


Test Results 22 - 26 87 - 92
(414 - 455) (565 - 620)

(1) The strength and elongation properties reported were obtained from a .505 tensile specimen artificially
aged at 220F (104C) for 48 hours, as permitted by AWS A5.20-95. A naturally aged tensile specimen
may take months to achieve the specified properties. See AWS A5.20-95, paragraph A8.3. The time
required for the natural aging of weld deposits is dependent upon ambient conditions, weldment
geometry, the metallurgical structure of the weld deposit and other factors.

DIAMETERS / PACKAGING
600 Lb. 600 Lb.
Diameter 14 Lb. 22 Lb. 50 Lb. Speed-Feed Speed-Feed
Inches (mm) Coil Readi-Reel Coil Reel Drum

5/64 (2.0) ED014464 ED014515 ED014459


3/32 (2.4) ED012629 ED012628
7/64 (2.8) ED012632 ED012633 ED012631

30 www.linconelectric.com
INNERSHIELD NR-311 AWS A5.20-95: E70T-7

TYPICAL OPERATING PROCEDURES


Wire, Polarity Wire Feed Arc Approx. Melt-Off Deposition
Electrical Stickout Speed Voltage Current Rate Rate Efficiency
Wire Weight in/min (m/min) (volts) (amps) lbs/hr (kg/hr) lbs/hr (kg/hr) (%)

5/64 100 (2.5) 21 190 6.4 (2.9) 5.0 (2.3) 78


DC- 160 (4.1) 25 275 10.3 (4.7) 8.0 (3.6) 78
1-1/4 (32mm) 240 (6.1) 26 355 15.4 (7.0) 12.4 (5.6) 80
1.07 lbs/1000 300 (7.6) 28 410 19.3 (8.8) 15.8 (7.2) 82

75 (1.9) 21 200 7.0 (3.2) 5.4 (2.5) 77


3/32
135 (3.4) 24 300 13.1 (5.9) 10.2 (4.6) 78
DC-
150 (3.8) 25 325 14.6 (6.6) 11.4 (5.2) 78
1-1/2 (38mm)
210 (5.3) 27 400 20.4 (9.3) 16.5 (7.5) 81
1.62 lbs/1000
270 (6.9) 30 450 26.2 (11.9) 22.0 (10.0) 84

100 (2.5) 23.5 325 12.0 (5.4) 10.0 (4.5) 83


7/64
145 (3.7) 25.5 400 17.8 (8.1) 14.5 (6.6) 82
DC-
175 (4.4) 27 450 21.5 (9.8) 18.0 (8.2) 83
1-1/2 (38mm)
240 (6.1) 30.5 550 29.5 (13.4) 25.5 (11.6) 86
2.05 lbs/1000
300 (7.6) 33 625 36.9 (16.7) 33.0 (15.0) 89

NOTE: Above typical operating procedures are starting points and may be adjusted as required.

DEPOSIT COMPOSITION
%C %Mn %P %S %Si %Al

Requirements
Report 1.75 .03 .03 .60 1.8
AWS E70T-7 Only max. max. max. max. max.

Test Results .25 .50 .008 <.003 .10 1.46

This electrode, and others of the same AWS classification, are not required to deposit weld
metal capable of delivering any minimum specified Charpy V-Notch (CVN ) properties. It
should not be used in applications where minimum specified CVN properties are required.
Typical applications where minimum specified CVN properties are required include, but are
not restricted to, bridges, pressure vessels, and buildings in seismic zones. The user of this
product is responsible for determining whether minimum CVN properties are required for
the specific application.

31 www.linconelectric.com
INNERSHIELD NR-311 Ni AWS A5.29-98: E70T7-K2

Similar to NR-311, but with good Our quality driven manufacturing WELDING POSITIONS
Charpy V-Notch properties. High system certified to ISO 9001 and
deposition rates. Fast travel speeds. our exceptionally high grade raw
For single and multiple pass welding. materials mean every coil of
Innershield delivers great arc char- 1G 2F 2G
acteristics and superior feedability.
ADVANTAGE LINCOLN
High deposition rates and fast travel CONFORMANCE
speeds. TYPICAL APPLICATIONS
AWS A5.29-98: E70T7-K2
Produces a nominal 1.5% Nickel Fillet and lap welds. ASME SFA5.29: E70T7-K2
deposit for notch toughness. Lloyds: 2S-2YS
Horizontal butt welds such as
Color match on weathering steel column-to-column structural con- DNV: IIYMS
applications. nections. GL: 2YS
BV: SA2YM
Produces quality welds in moderate Deep groove welds. NKK: KSW 52 NH10
wind conditions with no tenting.
Square edge butt welds.
Self-shielded, flux-cored. No need
for external gas or flux. Structural fabrication, including
applications involving seismic
requirements.

MECHANICAL PROPERTIES(1) - As Welded per AWS A5.29

Charpy V-Notch
Yield Strength Tensile Strength Elongation ft-lbs (Joules) Hardness
Condition psi (MPa) psi (MPa) (%) @ -20F (-29C) Rockwell B

Requirements 58,000 (400) 70,000 (482) 20 20 (27)



AWS E70T7-K2 min. min. min. min. min.

64,000 - 75,000 80,000 - 89,000


Test Results 22 - 31 20 - 50 (27 - 68) 87 - 92
(441 - 517) (551 - 613)

(1) The strength and elongation properties reported were obtained from a .505 tensile specimen artificially aged at 220F
(104C) for 48 hours, as permitted by AWS A5.29-98. A naturally aged tensile specimen may take months to achieve the
specified properties. The time required for the natural aging of weld deposits is dependent upon ambient conditions,
weldment geometry, the metallurgical structure of the weld deposit and other factors.

DIAMETERS / PACKAGING
Diameter 22 Lb. 50 Lb.
Inches (mm) Readi-Reel Coil

5/64 (2.0) ED017819


3/32 (2.4) ED017822
7/64 (2.8) ED017824

32 www.linconelectric.com
INNERSHIELD NR-311 Ni AWS A5.29-98: E70T7-K2

TYPICAL OPERATING PROCEDURES


Wire, Polarity Wire Feed Arc Approx. Melt-Off Deposition
Electrical Stickout Speed Voltage Current Rate Rate Efficiency
Wire Weight in/min (m/min) (volts) (amps) lbs/hr (kg/hr) lbs/hr (kg/hr) (%)

100 (2.5) 22 170 5.5 (2.5) 3.9 (1.8) 70


5/64
130 (3.3) 25 205 7.2 (3.3) 5.2 (2.4) 72
DC-
160 (4.0) 26 235 8.8 (4.0) 6.5 (2.9) 73
1 (25mm)
200 (5.0) 27 270 11.0 (5.0) 8.3 (3.8) 75
0.930 lbs/1000
240 (6.1) 28 295 13.3 (6.1) 10.0 (4.5) 75

75 (1.9) 21 200 6.2 (2.8) 4.2 (1.9) 67


3/32 100 (2.5) 22 245 8.3 (3.8) 5.9 (2.7) 71
DC- 125 (3.1) 24 285 10.4 (4.7) 7.5 (3.4) 72
1-1/4 (32mm) 150 (3.8) 26 330 12.5 (5.7) 9.1 (4.1) 72
1.39 lbs/1000 175 (4.4) 27 365 14.5 (6.6) 10.8 (4.9) 74
200 (5.0) 28 390 16.6 (7.6) 12.3 (5.6) 74

100 (2.5) 23 310 11.4 (5.2) 8.4 (3.8) 73


7/64
140 (3.5) 25 370 15.8 (7.2) 11.8 (5.4) 74
DC-
170 (4.3) 27 430 19.5 (8.9) 14.5 (6.6) 74
1-1/2 (38mm)
200 (5.0) 29 470 22.8 (10.4) 17.0 (7.7) 74
1.89 lbs/1000
240 (6.1) 30 520 27.2 (12.4) 20.4 (9.2) 75

NOTE: Above typical operating procedures are starting points and may be adjusted as required.

DEPOSIT COMPOSITION
%C %Mn %P %S %Si %Al %Ni %Mo %Cr %V

Requirements
.15 .03 .03 .80 1.80 .35 .15 .05
AWS E70T7-K2 .50 - 1.75 1.00 - 2.00
max. max. max. max. max. max. max. max.

Test Results .06 1.23 .005 <.003 .20 1.24 1.28 <.01 .03 <.01

This electrode has been tested in accordance with FEMA 353 - Recommended
Specifications and Quality Assurance Guidelines for Steel Moment-Frame Construction for
Seismic Applications and is capable of depositing weld metal that delivers minimum CVN
properties of 40 ft-lbs. at 70F (95 Joules at 21C)at low and high heat input levels. As
required by the AWS classification, it meets a minimum CVN of 20 ft-lbs. at -20F (27 Joules
at -29C), when tested in accordance with AWS A5.20. This electrode will also deposit weld
metal that will meet the requirements for H16 as tested according to AWS A4.3
FEMA 353 test certificates are available upon request.

33 www.linconelectric.com
INNERSHIELD NS-3M AWS A5.20-95: E70T-4

Extremely high deposition rate wire Our quality driven manufacturing WELDING POSITIONS
designed for automatic and semiauto- system certified to ISO 9001
matic welding on mild steel and some and our exceptionally high grade
low alloy steels. Resistant to cracking raw materials mean every coil of
2G
on high sulfur steel and porosity on Innershield delivers great arc 1G 2F

mildly rusty, oily or dirty plates. Soft, characteristics and superior


low penetrating arc. feedability.
CONFORMANCE
ADVANTAGE LINCOLN AWS A5.20-95: E70T-4
TYPICAL APPLICATIONS ASME SFA-5.20: E70T-4
High deposition rates for excellent ABS: E70T-4 per AWS A5.20-95
productivity. Structural fabrication where no
seismic requirements exist.
Resists porosity on mildly rusty, oil
or dirty plate. Machinery bases.
Easy slag removal even in deep Heavy equipment repair.
grooves.
Multiple pass fillet and lap welds.
Resists cracking on high sulfur steel.
Corner welds and single pass butt
Self-shielded, flux-cored. No need welds.
for external gas or flux.
Single pass 1/4 - 1/2
Produces quality welds in moderate
(6.4 - 12.7mm) fillet and lap welds.
wind conditions with no tenting.
Soft, low penetration arc.

MECHANICAL PROPERTIES(1) - As Welded per AWS A5.20

Yield Strength Tensile Strength Elongation Hardness


psi (MPa) psi (MPa) (%) Rockwell B

Requirements 58,000 (400) 70,000 (480) 22



AWS E70T-4 min. min. min.

60,000 - 70,000 72,000 - 93,000 22 - 30 85 - 95


Test Results
(414 - 483) (497 - 641)

(1) The strength and elongation properties reported were obtained from a .505 tensile specimen artificially
aged at 220F (104C) for 48 hours, as permitted by AWS A5.20-95. A naturally aged tensile specimen may
take months to achieve the specified properties. See AWS A5.20-95, paragraph A8.3. The time required for
the natural aging of weld deposits is dependent upon ambient conditions, weldment geometry, the
metallurgical structure of the weld deposit and other factors.

DIAMETERS / PACKAGING
600 Lb.
Diameter 14 Lb. 22 Lb. 50 Lb. Speed-Feed
Inches (mm) Coil Readi-Reel Coil Drum

5/64 (2.0) ED012739 ED017905 ED012740


3/32 (2.4) ED012736 ED012735
.120 (3.0) ED012732 ED012731

34 www.linconelectric.com
INNERSHIELD NS-3M AWS A5.20-95: E70T-4

TYPICAL OPERATING PROCEDURES


Wire, Polarity Wire Feed Arc Approx. Melt-Off Deposition
Electrical Stickout) Speed Voltage Current Rate Rate Efficiency
Wire Weight in/min (m/min) (volts) (amps) lbs/hr (kg/hr) lbs/hr (kg/hr) (%)

5/64 200 (5.1) 30 280 12.2 (5.5) 10.1 (4.6) 83


DC+ 240 (6.1) 31 315 14.8 (6.7) 12.1 (5.5) 82
2 (51mm) 260 (6.6) 31 330 16.0 (7.3) 13.2 (6.0) 83
1.03 lbs/1000 300 (7.6) 32 350 18.6 (8.4) 15.2 (6.9) 82

110 (2.8) 29 250 10.1 (4.6) 8.2 (3.7) 81


3/32
150 (3.8) 30 300 14.0 (6.4) 11.7 (5.3) 84
DC+
185 (4.7) 31 350 17.4 (7.9) 14.6 (6.6) 84
2-3/4 (70mm)
230 (5.8) 32 400 21.6 (9.8) 18.3 (8.3) 85
1.53 lbs/1000
275 (7.0) 33 450 26.0 (11.8) 22.0 (10.0) 85

.120 140 (3.6) 29 380 19.8 (9.0) 15.5 (7.0) 78


DC+ 175 (4.4) 30 450 24.6 (11.2) 20.0 (9.1) 81
2-3/4 (70mm) 200 (5.1) 31 500 28.0 (12.7) 23.2 (10.5) 83
2.34 lbs/1000 225 (5.7) 32 550 31.4 (14.2) 26.2 (11.9) 83

.120 210 (5.3) 36 450 29.0 (13.2) 25.0 (11.3) 86


DC+ 250 (6.4) 37 500 34.5 (15.6) 29.0 (13.2) 84
3-3/4 (95mm) 300 (7.6) 38 550 41.5 (18.8) 34.0 (15.4) 82
2.34 lbs/1000 355 (9.0) 39 600 49.0 (22.2) 39.5 (18.0) 81

NOTE: Above typical operating procedures are starting points and may be adjusted as required.

DEPOSIT COMPOSITION
%C %Mn %P %S %Si %Al

Requirements
Report 1.75 .03 .03 .60 1.8
AWS E70T-4 Only max. max. max. max. max..

Test Results .25 .45 .006 <.003 .29 1.59

This electrode, and others of the same AWS classification, are not required to deposit weld
metal capable of delivering any minimum specified Charpy V-Notch (CVN ) properties. It
should not be used in applications where minimum specified CVN properties are required.
Typical applications where minimum specified CVN properties are required include, but are
not restricted to, bridges, pressure vessels, and buildings in seismic zones. The user of this
product is responsible for determining whether minimum CVN properties are required for
the specific application.

35 www.linconelectric.com
INNERSHIELD NR-207 & NR-207-H AWS A5.29-98: E71T8-K6

Optimum performance on vertical Our quality driven manufacturing WELDING POSITIONS


down, hot, fill and cap passes on system certified to ISO 9001
standard cross-country pipelines and and our exceptionally high grade
arctic grade pipe. Excellent crack raw materials mean every coil of
resistance and CTOD and Innershield delivers great arc 1G 2F 2G
Charpy V-Notch properties. characteristics and superior
Recommended API Pipe Grades X42 feedability.
through X70.


5G


3G 4G

TYPICAL APPLICATIONS
ADVANTAGE LINCOLN Standard cross country pipelines.
Use these wires instead of stick for Arctic grade pipe. CONFORMANCE
improved productivity on pipeline AWS A5.29-98: E71T8-K6
projects. ASME SFA5.29: E71T8-K6
Self-shielded, flux-cored. No need DIFFUSIBLE HYDROGEN ABS: E71T8-K6
for external gas or flux. DNV: IIIYMSH15
NR-207-H will deposit weld
Produces quality welds in moderate BV: SA3YMH
material with diffusible hydrogen
wind conditions with no tenting. GL: 3YSH15
levels of less than 8.0 ml/100g.

MECHANICAL PROPERTIES(1) - As Welded per AWS A5.29

Charpy V-Notch
Yield Strength Tensile Strength Elongation ft-lbs (Joules) Hardness
psi (MPa) psi (MPa) (%) @ -20F (-29C) @-40F (-40C) Rockwell B

Requirements 58,000 (400) 70,000 - 90,000 20 20 (27)



AWS E71T-K6 min. (483 - 620) min. min. --

58,000 - 64,000 75,000 - 80,000 130 - 170 109


Test Results 20 - 33 84 - 90
(400 - 441) (517 - 551) (176 - 230) (147)

(1) The strength and elongation properties reported were obtained from a .505 tensile specimen artificially aged at 220F (104C) for 48 hours,
as permitted by AWS A5.29-98. A naturally aged tensile specimen may take months to achieve the specified properties. The time required
for the natural aging of weld deposits is dependent upon ambient conditions, weldment geometry, the metallurgical structure of the weld
deposit and other factors.

DIAMETERS / PACKAGING

Diameter 14 Lb. Coil 14 Lb. Coil


Inches (mm) (56 Lb. Carton) (56 Lb. Pail)

NR-207
.068 (1.7) ED016312
5/64 (2.0) ED012437 ED012438

NR-207-H
.068 (1.7) EDS19565
5/64 (2.0) EDS19568

36 www.linconelectric.com
INNERSHIELD NR-207 & NR-207-H AWS A5.29-98: E71T8-K6

TYPICAL OPERATING PROCEDURES


Wire, Polarity Wire Feed Arc Approx. Melt-Off Deposition
Electrical Stickout Speed Voltage Current Rate Rate Efficiency
Wire Weight in/min (m/min) (volts) (amps) lbs/hr (kg/hr) lbs/hr (kg/hr) (%)

.068 80 (2.0) 17.5 190 3.8 (1.7) 3.0 (1.3) 79


DC- 105 (2.6) 18.5 230 5.0 (2.2) 4.0 (1.8) 80
3/4 (19mm) 120 (3.0) 19.5 245 5.7 (2.5) 4.5 (2.0) 79
0.078 lbs/1000 145 (3.6) 21.5 275 6.8 (3.0) 5.5 (2.4) 81
170 (4.3) 21.5 295 8.0 (3.6) 6.4 (2.9) 80

70 (1.7) 17.5 205 4.5 (2.0) 3.4 (1.5) 76


5/64
80 (2.0) 18.5 225 5.1 (2.3) 3.9 (1.7) 76
DC-
90 (2.2) 18.5 240 5.8 (2.6) 4.5 (2.0) 78
3/4 (19mm)
110 (2.7) 20.5 275 7.0 (3.1) 5.5 (2.4) 79
1.04 lbs/1000
130 (3.3) 20.5 300 8.3 (3.7) 6.5 (2.9) 78

NOTE: Above typical operating procedures are starting points and may be adjusted as required.

DEPOSIT COMPOSITION
%C %Mn %P %S %Si %Al %Ni %Cr %Mo %V

Requirements
.15 .50- .03 .03 .80 1.80 .40- .20 .15 .05
AWS E71T8-K6
max. 1.50 max. max. max. max. 1.00 max. max. max.

Test Results .06 .94 .005 <.003 .26 1.07 .76 .02 .02 <.01

37 www.linconelectric.com
INNERSHIELD NR-208-H AWS A5.29-98: E91T8-G

Similar to NR-207-H, but with higher Our quality driven manufacturing WELDING POSITIONS
strength. Produces weld deposits system certified to ISO 9001
exceeding 80,000 psi yield strength and our exceptionally high grade
with excellent low temperature raw materials mean every coil of
impacts. Recommended for API Pipe Innershield delivers great arc 1G 2F 2G
Grade X80. characteristics and superior
feedability.

ADVANTAGE LINCOLN 4G



3G 5G
TYPICAL APPLICATIONS
Use instead of stick for improved
productivity on pipeline projects. Standard cross-country pipelines.
Arctic-grade pipe. CONFORMANCE
Produces weld deposits exceeding
80,000 psi yield strength. AWS A5.29-98: E91T8-G
Self-shielded, flux-cored. No need ASME: SFA-5.20: E91T8-G
DIFFUSIBLE HYDROGEN
for external gas or flux.
NR-208-H will deposit weld
Produces quality welds in moderate material with diffusible hydrogen
wind conditions with no tenting. levels of less than 8.0 ml/100g.

MECHANICAL PROPERTIES(1) - As Welded per AWS A5.29

Charpy V-Notch
Yield Strength Tensile Strength Elongation ft-lbs (Joules) Hardness
psi (MPa) psi (MPa) (%) @ -20F (-29C) @-40F (-40C) Rockwell B

Requirements 78,000 (538) 90,000 - 110,000 17 Not Not


AWS E91T8-G min. (620 - 758) min. Specified Specified --

81,000 - 86,000 94,000 - 99,000 50 44


Test Results 25 - 27 90 - 96
(558 - 593) (648 - 682) (67) (59)

(1) The strength and elongation properties reported were obtained from a .505 tensile specimen artificially aged at 220F (104C) for 48 hours, as
permitted by AWS A5.20-95. A naturally aged tensile specimen may take months to achieve the specified properties. See AWS A5.20-95,
paragraph A8.3. The time required for the natural aging of weld deposits is dependent upon ambient conditions, weldment geometry, the
metallurgical structure of the weld deposit and other factors.

DIAMETERS / PACKAGING

Diameter 14 Lb. Coil


Inches (mm) (56 Lb. Pail)

5/64 (2.0) ED023366

38 www.linconelectric.com
INNERSHIELD NR-208-H AWS A5.29-98: E91T8-G

TYPICAL OPERATING PROCEDURES


Wire, Polarity Wire Feed Arc Approx. Melt-Off Deposition
Electrical Stickout Speed Voltage Current Rate Rate Efficiency
Wire Weight in/min (m/min) (volts) (amps) lbs/hr (kg/hr) lbs/hr (kg/hr) (%)

70 (1.7) 16.5 195 4.0 (1.8) 3.2 (1.4) 81


5/64
80 (2.0) 17.5 220 4.6 (2.1) 3.9 (1.7) 84
DC-
90 (2.2) 18.5 235 5.4 (2.4) 4.5 (2.0) 84
3/4 (19mm)
110 (2.7) 19.5 270 6.5 (2.9) 5.5 (2.4) 85
1.04 lbs/1000
130 (3.3) 19.5 295 7.6 (3.5) 6.5 (2.9) 85

NOTE: Above typical operating procedures are starting points and may be adjusted as required.

DEPOSIT COMPOSITION

%C %Mn* %P %S %Si* %Al* %Ni* %Cr* %Mo* %V*

Requirements
Report 1.75 .03 .03 .80 1.80 .50 .30 .20 .10
AWS E91T8-G
only min. max. max. min. min. min. min. min. min.

Test Results .05 2.13 .011 <.002 .25 1.13 .79 .02 <.01 <.01

NOTE: In order to meet the alloy requirements of the G group, the weld deposit needs to have the minimum, as specified
in the table, of only one of the elements marked with an asterisk.

39 www.linconelectric.com
AGENCY APPROVALS (1)

Innershield AWS/ ABS Lloyds DNV BV CWB/CSA GL


Wire ASME Grade Grade Grade Grade Grade Grade Military Other

NR-203 E61T8-K6 3SA 3SH15 IIIMSH15(3) JIS


Nickel C

NR-1 E70T-3

NR-5 E70T-3

NS-3M E70T-4 E4802T-4-CH JIS

NR-305 E70T-6 2SA-2YSA IIYMS(2) SA2YM(2) E4802T-6-CH 2YS(2) JIS

NR-311 E70T-7 E4802T-7-CH JIS

NR-131 E70T-10 JIS

NR-311 Ni E70T7-K2 2SA-2YSA 2S-2YS IIYMS SA2YM 2YS JIS, NKK

NR-202 E71T-7

NR-203MP E71T-8J 3SA-3YSAH15 3S-3YSH15 IIIYMSH15 SA3YMH E4801T-8-CH 3YSH15 JIS, NKK

NR-232 E71T-8 3SA-3YSAH15 3S-3YSH15 IIIYMSH15 SA3YMH E4801T-8-CH 3YSH10 MIL-71T-8AS JIS, TUV

NR-203 Ni E71T8-K2 4SA-4YSAH10 JIS


C Plus

NR-207 E71T8-K6 IIIYMSH15 SA3YMH E71T8-K6-H16 3YSH15 JIS, TUV,


NKK

NR-207-H E71T8-K6 JIS, TUV

NR-203 E71T8-Ni1 3SA-3YSA 3S-3YSH15 IIIYMSH15 E71T8-Ni1-H16 3YSH15 JIS, TUV


Nickel 1%

NR-211-MP E71T-11 E4801T-11-CH JIS

NR-212 E71TG-G E71TG-G-CH JIS

NR-152 E71T-14 JIS

NR-208-H E91T8-G JIS, TUV

ABS: American Bureau of Shipping (1)


Approvals are updated periodically. Consult your local Lincoln district office for the latest Approval/Grade revision.
Lloyds: Lloyds Register of Shipping (2)
3/32 diameter only.
DNV: Det Norske Veritas (3)
Tested at -40F.
GL: Germanischer Lloyd
BV: Bureau Veritas

40 www.linconelectric.com
STORING INNERSHIELD ELECTRODES

In general, Innershield electrodes will produce weld deposits electrode removed from its original packaging be placed in
which achieve hydrogen levels below 16 ml per 100 grams poly bags (4 mil minimum thickness) when not in use.
deposited metal. These products, like other products which
Innershield electrodes will evidence high moisture levels in the
produce deposits low in hydrogen, must be protected from
form of gas tracks, higher spatter and porosity. Any rusty elec-
exposure to the atmosphere in order to maintain hydrogen
trode should be discarded.
levels as low as possible, preventing rusting of the product
and prevent porosity during welding. Accordingly, the follow- Innershield Products Used for Applications Requiring
ing storage conditions are recommended for Innershield More Restrictive Hydrogen Control (-H Electrodes)
electrodes in their original, unopened boxes and plastic bags.
The AWS specifications for flux-cored electrodes, AWS A5.20
The recommended storage conditions are such that they and A5.29, state that Flux-cored arc welding is generally
maintain storage conditions above the dew point to prevent considered to be a low hydrogen welding process. To further
moisture contamination on product. clarify the issue, these specifications makes available optional
supplemental designators for maximum diffusible hydrogen
For best results, electrode should be consumed as soon as
levels of 4, 8 and 16 ml per 100 grams of deposited weld
practicable. Properly store electrode may be kept up to three
metal.
years from the date of manufacture. Consult your Lincoln
distributor or sales representative if there is a question as to Some Innershield products have been designed and
when the electrode was made. manufactured to produce weld deposits meeting more
stringent diffusible hydrogen requirements. These electrodes
Once the electrode packaging is opened, Innershield elec-
are usually distinguished by an H added to the product
trodes can be subject to contamination from atmospheric
name. These electrodes will remain relatively dry under
moisture. Care has been taken in the design of these
recommended storage conditions in their original, unopened
products to ensure that they are essentially resistant to
package or container.
moisture pick-up; however, condensation of the moisture
from the atmosphere onto the surface of the electrode can be For applications in which the weld metal hydrogen must be
sufficient enough to degrade the product. controlled (usually H8 or lower), or where shipping and storage
conditions are not controlled or known, only hermetically
The following minimum precautions should be taken to
sealed packaging is recommended. Innershield electrodes are
safeguard the product after opening the original package.
available in hermetically sealed packages on a special order
Electrode should be used within approximately 1 week after
basis.
opening the original package. Opened electrodes should not
be exposed to damp moisture conditions or extremes in Once the package has been opened, the electrode should be
temperature and/or humidity where surface condensation can used as soon as practicable.
occur. Electrodes mounted on wire feeders should be
protected against condensation. It is recommended that

Customer Assistance Policy


The business of The Lincoln Electric Company is manufacturing and selling high quality welding equipment, consumables, and cutting equipment. Our challenge is to meet
the needs of our customers and to exceed their expectations. On occasion, purchasers may ask Lincoln Electric for advice or information about their use of our products. We
respond to our customers based on the best information in our possession at that time. Lincoln Electric is not in a position to warrant or guarantee such advice, and assumes
no liability, with respect to such information or advice. We expressly disclaim any warranty of any kind, including any warranty of fitness for any customers particular purpose,
with respect to such information or advice. As a matter of practical consideration, we also cannot assume any responsibility for updating or correcting any such information or
advice once it has been given, nor does the provision of information or advice create, expand or alter any warranty with respect to the sale of our products.

Lincoln Electric is a responsive manufacturer, but the selection and use of specific products sold by Lincoln Electric is solely within the control of, and remains the sole respon-
sibility of the customer. Many variables beyond the control of Lincoln Electric affect the results obtained in applying this type of fabrication methods and service requirements.

41 www.linconelectric.com
NOTES

42 www.linconelectric.com
NOTES

43 www.linconelectric.com
LINCOLN NORTH AMERICA
DISTRICT SALES OFFICES
HAWAII MICHIGAN OHIO UTAH
U.S.A. AKRON 44236-4680 MIDVALE 84047-3759
See SEATTLE DETROIT 48034-4005
ALABAMA District Office (248) 353-9680 (330) 342-8009 (801) 233-9353
BIRMINGHAM 35124-1156 (206) 575-2456 FLUSHING 48433-1855 CINCINNATI 45242-3706 VIRGINIA
(205) 988-8232 (810) 487-1310 (513) 554-4440 HERNDON 20170-5227
IDAHO
MOBILE 36582-5209 GRAND RAPIDS 49512-3924 CLEVELAND 44143-1433 Washington, D.C.
BOISE 83616-6646
(251) 443-6524 (616) 942-8780 (216) 289-4160 (703) 904-7735
(208) 938-2302
COLUMBUS 43221-4073 ROANOKE
ALASKA MINNESOTA
ILLINOIS (614) 488-7913
Contact SEATTLE MINNEAPOLIS 55447-5435 (703) 904-7735
CHICAGO 60527-5629 DAYTON 45458
District Office (612) 551-1990 WILLIAMSBURG 23602-7048
(630) 920-1500 (937) 885-6964
(206) 575-2456 (757) 870-5508
PEORIA 60527-5629 MISSISSIPPI TOLEDO 43528-9483
ARIZONA (630) 920-1500 JACKSON 39212-9635 (419) 867-7284 WASHINGTON
PHOENIX 85260-1768 (601) 372-7679 VANCOUVER 98661-8023
INDIANA OKLAHOMA
(480) 348-2004 (360) 693-4712
EVANSVILLE 47630 MISSOURI OKLAHOMA CITY 73119-2416 SPOKANE 99005-9637
ARKANSAS (812) 842-2775 KANSAS CITY (KS) 66214-1625 (405) 686-1170 (509) 468-2770
LITTLE ROCK 72032-4371 FT. WAYNE 46825-5547 (913) 894-0888 TULSA 74146-1622
(501) 764-0480 (219) 484-4422 ST. LOUIS 63146-3572 (918) 622-9353 WEST VIRGINIA
SOUTH BEND 46561-9160 (314) 993-5465 CHARLESTON 25526-9796
CALIFORNIA PENNSYLVANIA
(219) 674-5523 SPRINGFIELD 65804 (304) 757-9862
FRESNO 93722-3949 ERIE 16506-2979
INDIANAPOLIS 46038-9459 (417) 823-0574 WISCONSIN
(559) 276-0110 (814) 835-3531
LOS ANGELES 90670-2936 (317) 845-8445 MONTANA GREEN BAY 54302-1829
JOHNSTOWN 15905-2506
(562) 906-7700 IOWA Contact SEATTLE (814) 535-5895 (920) 435-1012
SACRAMENTO 95677-4729 CEDAR RAPIDS 52402-3160 District Office PHILADELPHIA 19008-4310 MILWAUKEE 53186-0403
(916) 630-1885 (319) 362-6804 (206) 575-2456 (610) 543-9462 (262) 650-9364
SAN DIEGO 92108-3911 DAVENPORT 52806-1344 NEBRASKA PITTSBURGH 15275-1002
(619) 208-9001 (563) 386-6522 (412) 787-7733
SAN FRANCISCO 94550-9657 DES MOINES 50265-6218
LINCOLN 68521-4806
YORK 17404-1144
CANADA
(402) 474-5697
(925) 443-9353 (515) 224-4121 OMAHA 68046-2826 (717) 764-6565 ALBERTA
COLORADO KANSAS (402) 339-1809 SOUTH CAROLINA CALGARY
DENVER 80112-5115 KANSAS CITY 66214-1625 GREENVILLE 29681-4724 (403) 253-9600/(877) 600-WELD
NEW JERSEY EDMONTON
(303) 742-8887 (913) 894-0888 EDISON 08837-3939 (864) 967-4157
WICHITA 67037-9614 COLUMBIA 29209 (780) 436-7385
CONNECTICUT (732) 225-2000 WINNIPEG
NORTH HAVEN 06238-1090 (316) 788-7367 (803) 783-2851
NEW MEXICO (204) 488-6398
(860) 742-8887 KENTUCKY ALBUQUERQUE 87008 SOUTH DAKOTA
LOUISVILLE 47112-7025 SIOUX FALLS 57108-2609 BRITISH COLUMBIA
WASHINGTON DC (505) 286-4801 VANCOUVER
HERNDON, VA 20170-5227 (502) 727-7335 (605) 339-6522
NEW YORK (604) 318-9114
(703) 904-7735 LOUISIANA ALBANY TENNESSEE
BATON ROUGE 70808-3150 KNOXVILLE 37923-4506 MARITIMES
FLORIDA (315) 432-0281 NEW BRUNSWICK
JACKSONVILLE 32216-4634 (225) 922-5151 BUFFALO (865) 693-5513
LAFAYETTE 70507-3126 MEMPHIS 38115-5946 (506) 658-0877
(904) 642-3177 (315) 432-0281
MIAMI 33178-1175 (337) 886-1090 NEW YORK CITY (901) 363-1075 MANITOBA
(305) 888-3203 SHREVEPORT 71108-2521 (888) 269-6755 NASHVILLE 37027 WINNIPEG
ORLANDO 32714-1974 (318) 869-3531 SYRACUSE 13057-1040 (615) 236-1144 (204) 488-6398
(407) 788-8557 MARYLAND (315) 432-0281 TRI-CITIES 37601-3411
ONTARIO
TAMPA 33594-6387 BALTIMORE 21050-3067 (423) 928-6047
NORTH CAROLINA MISSISSAUGA
(770) 475-0955 (443) 831-0416 CHARLOTTE 28273-6200 TEXAS (905) 565-5600
GEORGIA MASSACHUSETTS (704) 588-3251 DALLAS 76051-7602 TORONTO
ATLANTA 30076-4914 BOSTON 02452-8405 RALEIGH 27604-8456 (817) 329-9353 (416) 421-2600/(800) 268-0812
(770) 475-0955 (781) 899-2010 (919) 231-5855 HOUSTON 77060-3143
QUEBEC
SAVANNAH 31324-5180 (281) 847-9444
MONTREAL
(912) 727-4286 SAN ANTONIO 78133-3502
(450) 654-3121
(830) 964-2421

LINCOLN INTERNATIONAL HEADQUARTERS


LATIN AMERICA EUROPE RUSSIA, AFRICA & MIDDLE EAST ASIA PACIFIC
Miami, Florida U.S.A. The Netherlands Cleveland, Ohio U.S.A. Singapore
Phone: (305) 888-3203 Phone: 31 24 3522 911 Phone: (216) 481-8100 Phone: 65 276 0878

HARRIS CALORIFIC DIVISION


2345 Murphy Blvd., Gainesville, Georgia 30504 U.S.A.
Phone: 1-800-241-0804 Fax: (770) 535-0544 Web Site: www.harriscal.com

DISTRIBUTED BY:

Cored Wire
C3.2000 8/02

Vous aimerez peut-être aussi