Académique Documents
Professionnel Documents
Culture Documents
Location : FS1
Ast3 = Mm-/0.87*fy*Z3 = 725.9 mm2 Ast3(req) = 323 mm2/m Ast3(pro) = 1005 mm2
Ast4 = Mm+/0.87*fy*Z4 = 1487.3 mm2 Ast4(req) = 661 mm2/m Ast4(pro) = 1005 mm2
Ast3 = Mm-/0.87*fy*Z3 = 726 mm2 Ast3(req) = 323 mm2/m Ast3(pro) = 1005 mm2
Ast4 = Mm+/0.87*fy*Z4 = 1487 mm2 Ast4(req) = 661 mm2/m Ast4(pro) = 1005 mm2
(2) Around Head of Pile/Column (critical plane is at 1.5dd from the face of pile/column)
Vt = n*Lx*Ly = 664.7 KN
Veff = 1.15*Vt = 764.5 KN
Perimeter Length (p1) = 4*(CL + 3*dd) If 3*dd>Ld ,d1=d and If 3*dd<=Ld,d1=dd
= 4880 mm d1 = 340.0 mm
vp1 = Veff / p1*d1 = 0.46 N/mm 2
(3) Around Head of Drop Panel (Critical plane is at 1.5d from the face of Drop Panel)
Panel Area within Perimeter = (Ld + 3*d)^2 where d = 165.0 mm
= 3.98 m2
Loaded Area Supported (A) = 16.27 m2
Veff = 1.15*A*n = 614.2 KN
Perimeter Length (p2) = 4*(Ld + 3*d) Note : If Ld=0,Case 3 same as Case 2
= 7980 mm
vp2 = Veff / p2*d = 0.47 N/mm2
Average Tension Ast in each direction over column head
Ast(avr) = (Ast1+Ast1)/2 = 1005 mm2
100*Ast(avr)/b*d = 0.61 <= 3.0 0.61
400/d = 2.42 > 1.0 2.42
vc = ( 0.79*(100*Ast(avr)/b*d)^1/3*(400/d)^1/4*(fcu/25)^1/3 )/1.25 (Table 3.9 BS 8110:1985)
vc = 0.71 N/mm2 > vp2 OK