Vous êtes sur la page 1sur 3

PROJECT : AEON RAWANG Date : ###

Location : FS1

FLAT SLAB DESIGN TO BS8110 : 1985 (FLAT SLAB WITHOUT DROP)


BASIC DATA :
Shorter Span (Lx) = 4500 mm
Longer Span (Ly) = 4500 mm
Slab Thickness (ts) = 200 mm
Finishes Thickness (tf) = 475 mm
Drop Panel size (Ld) = 1500 mm
Drop Panel Thickness (td) = 200 mm
Concrete Strength (fcu) = 30 N/mm2
Rebar Strength (fy) = 460 N/mm2
FS of Dead Load = 1.4
FS of Live Load = 1.6
Pile/Column Size (CL) = 200 mm
LOADING :
Dead Load (DL)
Slab Self Weight = ts*24 = 4.80 KN/m2
Finishes Self Weight = tf *24 = 11.40 KN/m2
Drop Panel Self Weight = 0.53 KN/m2
Partition Load = 1.00 KN/m2
Total = 17.73 KN/m2

Live Load (LL) = 5.0 KN/m2

n = 1.4*DL + 1.6*LL = 32.83 KN/m2


F = n*Lx*Ly = 664.7 KN

For Longer Span


hc = (CL^2*4/Pi)^1/2 = 225.7 mm

leff = Ly - 2/3*hc = 4349.5 mm


Ld(min) = Lx/3
= 1500.0 mm < Ld Consired Drop
Width of Column Strip (bc) = Lx/2
= 2250.0 mm
Moment in Longer Span Table 3.19 BS8110 :1985
M- = c1*F*leff = 182.2 KN.m (First Interior Support ,c1=0.063)
M+ = c2*F*leff = 205.3 KN.m (Centre of Interior Span , c2=0.071)

Moment in Column Strip Table 3.20 BS8110 :1985 where d = 165 mm


Mc- = 0.75*M- = 136.6 KN.m Mc-/bc*d^2*fcu (k1) = 0.074 < 0.156 compression bar is not required
Mc+ = 0.55*M+ = 112.9 KN.m Mc+/bc*d^2*fcu (k2) = 0.061 < 0.156 compression bar is not required

z1=d*(0.5+(0.25-k1/0.9)^1/2) = 150.0 mm Z1 = 150.0 mm


z2=d*(0.5+(0.25-k2/0.9)^1/2) = 152.8 mm Z2 = 152.8 mm
z <= 0.95*d where 0.95*d = 156.8 mm Ast(min) = 260.0 mm2/m
Ast1 = Mc-/0.87*fy*Z1 = 2276 mm2 Ast1(req) = 1011 mm2/m Ast1(pro) = 1005 mm2
Ast2 = Mc+/0.87*fy*Z2 = 1846 mm2 Ast2(req) = 820 mm2/m Ast2(pro) = 1005 mm2

Moment in Middle Strip Table 3.20 BS8110 :1985


Mm- = 0.25*M- = 45.5 KN.m Mm-/bc*d^2*fcu (k3) = 0.025 < 0.156 compression bar is not required
Mm+ = 0.45*M+ = 92.4 KN.m Mm+/bc*d^2*fcu (k4) = 0.050 < 0.156 compression bar is not required

z3=d*(0.5+(0.25-k3/0.9)^1/2) = 160.3 mm Z3 = 156.8 mm


z4=d*(0.5+(0.25-k4/0.9)^1/2) = 155.2 mm Z4 = 155.2 mm

Ast3 = Mm-/0.87*fy*Z3 = 725.9 mm2 Ast3(req) = 323 mm2/m Ast3(pro) = 1005 mm2
Ast4 = Mm+/0.87*fy*Z4 = 1487.3 mm2 Ast4(req) = 661 mm2/m Ast4(pro) = 1005 mm2

For Shorter Span


hc = (CL^2*4/Pi)^1/2 = 225.7 mm
leff = Lx - 2/3* hc = 4349.5 mm
Width of Column Strip (bc) = Lx/2
= 2250.0 mm
Moment in Shorter Span Table 3.19 BS8110 : 1985
M- = c1*F*leff = 182.2 KN.m (First Interior Support ,c1=0.063)
M+ = c2*F*leff = 205.3 KN.m (Centre of Interior Span , c2=0.071)

Moment in Column Strip Table 3.20 BS8110 :1985 where d = 165 mm


Mc- =0.75*M- *(1-(Ly-2*bc)/2*Ly) = 136.6 KN.m Mc-/bc*d^2*fcu (k1) = 0.074 < 0.156 compression bar is not required
Mc+ =0.55*M+ *(1-(Ly-2*bc)/2*Ly) = 112.9 KN.m Mc+/bc*d^2*fcu (k2) = 0.061 < 0.156 compression bar is not required

z1=d*(0.5+(0.25-k1/0.9)^1/2) = 150.0 mm Z1 = 150.0 mm


z2=d*(0.5+(0.25-k2/0.9)^1/2) = 152.8 mm Z2 = 152.8 mm
<= 0.95*d where 0.95*d = 156.8 mm Ast(min) = 260 mm2/m
Ast1 = M-/0.87*fy*Z1 = 2276 mm2 Ast1(req) = 1011 mm2/m Ast1(pro) = 1005 mm2

printed on :12/14/2017 KAJIMA DESIGN ASIA


Ast2 = M+/0.87*fy*Z2 = 1846 mm2 Ast2(req) = 820 mm2/m Ast2(pro) = 1005 mm2

Moment in Middle Strip Table 3.20 BS8110 :1985


Mm- =0.25*M-+(0.75*M- -Mc-) = 45.5 KN.m Mm-/(Ly-bc)*d^2*fcu (k3) = 0.025 < 0.156 compression bar is not required
Mm+ =0.45*M+ +(0.55*M+-Mc+) = 92.4 KN.m Mm+/(Ly-bc)*d^2*fcu (k4) = 0.050 < 0.156 compression bar is not required

z3=d*(0.5+(0.25-k3/0.9)^1/2) = 160.3 mm Z3 = 156.8 mm


z4=d*(0.5+(0.25-k4/0.9)^1/2) = 155.2 mm Z4 = 155.2 mm

Ast3 = Mm-/0.87*fy*Z3 = 726 mm2 Ast3(req) = 323 mm2/m Ast3(pro) = 1005 mm2
Ast4 = Mm+/0.87*fy*Z4 = 1487 mm2 Ast4(req) = 661 mm2/m Ast4(pro) = 1005 mm2

Deflection check (Critical situation occurs in longer span)


M+(tot)/Lx*d^2 = 1.68 where M+(tot) = Total panel positive moment in Longer span
fs = 5/8*fy*(Ast(req)/Ast(pro)) = 211.8 N/mm2
MF = 0.55 + (477 - fs)/ 120 (0.9 + M+(tot)/Lxx*d^2) (Table 3.11 BS8110 :1985)
= 1.41 <= 2.0
(S/d)all = MF*26*0.9 = 32.95 (Clause 3.7.8 BS8110 : 1985)
(S/d)act = Ly/d = 27.27 < 32.95 --- OK

Effective Shear Force in Flat Slab (Clause 3.7.6.2 BS8110 : 1985)


Punching Shear
(1) Ultimate Punching Shear
Vt = n*Lx*Ly = 664.7 KN where dd = (ts+td)-50-10
Veff = 1.15*Vt = 764.5 KN = 340.0 mm
vmax = Veff/4*CL*dd = 2.81 N/mm2
Max. concrete shear (vcmax) = 0.8*(fcu)^1/2 or 5N/mm2 whichever lesser
= 4.38 N/mm2 > vmax OK

(2) Around Head of Pile/Column (critical plane is at 1.5dd from the face of pile/column)
Vt = n*Lx*Ly = 664.7 KN
Veff = 1.15*Vt = 764.5 KN
Perimeter Length (p1) = 4*(CL + 3*dd) If 3*dd>Ld ,d1=d and If 3*dd<=Ld,d1=dd
= 4880 mm d1 = 340.0 mm
vp1 = Veff / p1*d1 = 0.46 N/mm 2

Average Tension Ast in each direction over column head


Ast(avr) = (Ast1+Ast1)/2 = 1005 mm2
100 x Ast(avr)/b*d1 = 0.30 <= 3.0 0.296
400/d1 = 1.18 > 1.0 1.18
vc = ( 0.79*(100*Ast(avr)/b*d)^1/3 *(400/d)^1/4*(fcu/25)^1/3 )/1.25 (Table 3.9 BS 8110:1985)
vc = 0.47 N/mm2 > vp1 OK

(3) Around Head of Drop Panel (Critical plane is at 1.5d from the face of Drop Panel)
Panel Area within Perimeter = (Ld + 3*d)^2 where d = 165.0 mm
= 3.98 m2
Loaded Area Supported (A) = 16.27 m2
Veff = 1.15*A*n = 614.2 KN
Perimeter Length (p2) = 4*(Ld + 3*d) Note : If Ld=0,Case 3 same as Case 2
= 7980 mm
vp2 = Veff / p2*d = 0.47 N/mm2
Average Tension Ast in each direction over column head
Ast(avr) = (Ast1+Ast1)/2 = 1005 mm2
100*Ast(avr)/b*d = 0.61 <= 3.0 0.61
400/d = 2.42 > 1.0 2.42
vc = ( 0.79*(100*Ast(avr)/b*d)^1/3*(400/d)^1/4*(fcu/25)^1/3 )/1.25 (Table 3.9 BS 8110:1985)
vc = 0.71 N/mm2 > vp2 OK

printed on :12/14/2017 KAJIMA DESIGN ASIA


PROJECT : AEON RAWANG Date : ###
Location : FS1
FLAT SLAB DESIGN SUMMARY SHEET (FLAT SLAB WITHOUT DROP)

Flat Slab Panel Size 4500 x 4500 mm


Flat SlabThickness 200 mm
Drop Panel Size 1500 x 1500 mm
Drop Panel Thickness 200 mm
Concrete Strength (fcu) 30 N/mm2
Rebar Strength (fy) 460 N/mm2
Dead Load 17.73 KN/m2
Live Load 5.00 KN/m2
Total Load per pile 460.4 KN

MOMENT Distribution at column strip


Factor Value M k Z As(req) Bar size S(max) S(pro) As(pro)
(KN.m) (KNm) (mm) (mm2/M) (mm) (mm) (mm) (mm2/M)
Near centre of 1st. span 0.083 240 132.0 10 200 393
1st. interior support -0.063 182.2 136.6 0.074 150.0 1011 16 198.8 200 1005
Centre of interior span 0.071 205.3 112.9 0.061 152.8 820 16 245.1 200 1005
Interior support -0.055 159 119.3 10 200 393

Longer Distribution at middle strip


Span M k Z As(req) Bar size S(max) S(pro) As(pro)
(KNm) (mm) (mm2/M) (mm) (mm) (mm) (mm2/M)
Near centre of 1st. span 108.0 10 200 393
1st. interior support 45.5 0.025 156.8 323 16 623.2 200 1005
Centre of interior span 92.4 0.050 155.2 661 16 304.2 200 1005
Interior support 39.8 10 200 393

MOMENT Distribution at column strip


Factor Value M k Z As(req) Bar size S(max) S(pro) As(pro)
(KN.m) (KNm) (mm) (mm2/M) (mm) (mm) (mm) (mm2/M)
Near centre of 1st. span 0.083 10 200 393
1st. interior support -0.063 182 136.6 0.074 150.0 1011 16 198.8 200 1005
Centre of interior span 0.071 205.3 112.9 0.061 152.8 820 16 245.1 200 1005
Interior support -0.055 10 200 393

Shorter Distribution at middle strip


Span M k Z As(req) Bar size S(max) S(pro) As(pro)
(KNm) (mm) (mm2/M) (mm) (mm) (mm) (mm2/M)
Near centre of 1st. span 10 200 393
1st. interior support 45.5 0.025 156.8 323 16 623.2 200 1005
Centre of interior span 92.4 0.050 155.2 661 16 304.2 200 1005
Interior support 10 200 393