Abstract
In practice, the effect of varying the flow of water in the condenser in a refrigeration system
operated by the vapor compression was determined, for which a equipment called a refrigeration
unit RA1-MKII is used in which a measure that is The flow of water occurs the variation of the
temperature, the pressure of the flow and this data is obtained directly by the use of software that is
incorporated with the equipment. In this way we obtained, among other values, stories such as the
coefficient of perfomance, water flow, heat extracted, heat entering among others, where our
analysis was based on the data of the coefficient of yield and the flow of water Condenser capacitor,
in order to analyze these characteristics and how to influence the steam compression cycle, a
coefficient of performance vs water flow in the capacitor was plotted, so that the influence of the
flow quantity of Water entering the condenser with respect to the refrigeration capacity that this
cycle was going to present.
12.00
Coeficiente de performance
11.00
10.00
9.00
8.00
7.00
6.00
5.00
0.0 2.0 4.0 6.0 8.0 10.0
Flujo de agua en el condensador