2 CIA2011 - Plant Processes & Safety Conference 2011 (22 – 23 November 2011) - Singapore
The Tyranny of
Complexity
Features, Options,…
Background
z If devices are used/configured incorrectly:
– The may inefficient/sub-optimal
– Incorrect operation
– Time consuming procedure, causing delays
z In the past, humans had to adopt to technology
– Technology should adopt to humans; perspective of
humans
– To get it right the first time
z Technicians are experienced:
– With screwdriver and multi-meter: not computers
z Need better tools
– Built-in Standard Operating Procedures (SOP) wizards
• Up-to-date, always available, specific to device
– Built-in reference material, guidance
4
– Reduce human error
CIA2011 - Plant Processes & Safety Conference 2011 (22 – 23 November 2011) - Singapore
Mix of Devices
z “Simple”
– Pressure, temperature, pH, conductivity…
z “Complex”
– Valve positioners, analysers, vibration All kinds of
device
transmitters, radar level transmitters, and types
bus diagnostics modules, etc.
5 CIA2011 - Plant Processes & Safety Conference 2011 (22 – 23 November 2011) - Singapore
Multiple Protocols
z EDDL is an integral part of protocols
– HART, FOUNDATION fieldbus, PROFIBUS, and
WirelessHART
6 CIA2011 - Plant Processes & Safety Conference 2011 (22 – 23 November 2011) - Singapore
Lots of Functionality
z Many different features
z Many different options
Parameter
names are not
as intuitive as
EDDL labels
7 CIA2011 - Plant Processes & Safety Conference 2011 (22 – 23 November 2011) - Singapore
Matching Usability
and Competency
EDDL – The Enabling Technology
Device Integration History
z 1992: EDDL (DD) first created
z 1998: FDT/DTM created
z 2004: EDDL (DD) standardized
z 2004: NAMUR NE 105 recommendation
z 2004: EDDL Cooperation Team formed
z 2006: EDDL with enhancement standardized
z 2007: FDT group joins EDDL Cooperation Team
2006
2004
1998
1992
9 CIA2011 - Plant Processes & Safety Conference 2011 (22 – 23 November 2011) - Singapore
EDDL Graphical Elements
Tabbed Card Gauge
Multi-pen Trend Chart
Navigation
Image
Frame Bargraph
Histogram Bar-chart
Multiple Waveform Graph
Table
z Content designed by device
Pop-Up Window
manufacturer
10 CIA2011 - Plant Processes & Safety Conference 2011 (22 – 23 November 2011) - Singapore
Hiding Complexity
12 CIA2011 - Plant Processes & Safety Conference 2011 (22 – 23 November 2011) - Singapore
Consistent Look & Feel
z EDDL has intrinsically consistent look & feel
13 CIA2011 - Plant Processes & Safety Conference 2011 (22 – 23 November 2011) - Singapore
Common Standard Functions
Failure No Communication
14 CIA2011 - Plant Processes & Safety Conference 2011 (22 – 23 November 2011) - Singapore
Device Setup Made
Easy
Configuration, parameterization,
and calibration trim
Independent of Protocol
Wireless Fieldbus
HART
16 CIA2011 - Plant Processes & Safety Conference 2011 (22 – 23 November 2011) - Singapore
Independent of Device Type
PRESSURE TEMPERATURE
FLOW
17 CIA2011 - Plant Processes & Safety Conference 2011 (22 – 23 November 2011) - Singapore
Graphics for Setup
Tabbed Card
Image
Navigation
Frame
Multiple Waveform Graph
Table
Pop-Up Window
18 CIA2011 - Plant Processes & Safety Conference 2011 (22 – 23 November 2011) - Singapore
“Wizards” – Guidance from Manufacturer
Expert
z Device Management z Handheld Field
System Communicator
19 CIA2011 - Plant Processes & Safety Conference 2011 (22 – 23 November 2011) - Singapore
Manufacturer Explanatory Text
Instructions
from
manufacturer
expert
20 CIA2011 - Plant Processes & Safety Conference 2011 (22 – 23 November 2011) - Singapore
EDDL Conditionals De-clutter
z Disable parameters z Enable when
when irrelevant applicable
Menus and
graphics etc.
adjust based on
prior selection to
only display valid
choices
21 CIA2011 - Plant Processes & Safety Conference 2011 (22 – 23 November 2011) - Singapore
Troubleshooting
Made Easy
Advanced Diagnostics
Troubleshooting
Device Status
Variable Status
23 CIA2011 - Plant Processes & Safety Conference 2011 (22 – 23 November 2011) - Singapore
Conditional Graphics to Alert User
24 CIA2011 - Plant Processes & Safety Conference 2011 (22 – 23 November 2011) - Singapore
Troubleshooting Tips and Graphics make
Maintenance Easy - Failed
25 CIA2011 - Plant Processes & Safety Conference 2011 (22 – 23 November 2011) - Singapore
Troubleshooting tips and Graphics make
Maintenance Easy - Maintenance
26 CIA2011 - Plant Processes & Safety Conference 2011 (22 – 23 November 2011) - Singapore
User Guidance
27 CIA2011 - Plant Processes & Safety Conference 2011 (22 – 23 November 2011) - Singapore
Trend Spotting
28 CIA2011 - Plant Processes & Safety Conference 2011 (22 – 23 November 2011) - Singapore
Advanced Diagnostics
29 CIA2011 - Plant Processes & Safety Conference 2011 (22 – 23 November 2011) - Singapore
Conclusion
Conclusion
z Devices are getting more feature rich
z Human centered user interface improves ease of
use
z EDDL is the underlying enabling technology
z Fieldbus and wireless is easy to use
31 CIA2011 - Plant Processes & Safety Conference 2011 (22 – 23 November 2011) - Singapore
For More Information
z www.eddl.org
32 CIA2011 - Plant Processes & Safety Conference 2011 (22 – 23 November 2011) - Singapore