BitupluS Ex isasuperiorgradeofbituminouswaterproofingmembranemanufacturedbyblendinga
mixtureofbitumenandSBS(StyreneButadieneStyrene)polymerstoobtainexcellentwaterproofingand
lowtemperatureflexibilityproperties.thepolymerizedbitumeniscoatedontoadimensionallystable
reinforcementcoreofnonwovenspunbondpolyesterrot-prooffabric.themembranehasexcellent
tensile&tearstrengthsandishighlyresistanttopuncture.itisflexibleandissuitableforapplicationswhere
highstructuralmovementisexpected.
characteristics polyester
Reinforcement
4 Excellentresistancetopositivewater&vapor
pressure
4 Gooddimensionalstabilityundertension
4 Excellent flexibility. Can accommodate high
1 structuralmovements
pEfilm
4 Highpunctureandfatigueresistance
4 Excellenttensileandtearstrengths
SBSModifiedBitumen
4 Highresistanceagainstwaterbornechemicals
4 Exhibitsgoodlowtemperatureflexibilitywithno pEfilm
For illustration purpose only
physicalstrain
www.henkelpolybit.com
unrolling the roll of BitupluS Ex membrane and
aligningthesidelaps.Re-rolltherollhalfwayand
standontheunrolledportiontopreventshifting.
Sideoverlapsshouldbeaminimumof100mm
andtheendoverlaps150mm.
torching
BitupluS Ex membrane is installed by using a
cylinderfedpropanegastorch.useofhand-held
roofingtorchisrecommendedasitaffordsagood
control.ifmultipleburnertorchingmachinesare
utilized, care must be taken to ensure the
applicationofuniformheatandavoidoverheating
ofthemembrane.Begintorchingtheembossed
polyethylene side of the rolled portion of the
membrane. proper torching procedure involves
TDS_Bituplus-Ex_GCC_0514
passingthetorchflameinan”l”patternapplying
about 75 percent of the heat across the coiled
portion of the roll and 25 percent across the
substrate,includingthelapareaofthepreviously internal Corner Details
installedmembrane.Asthemembraneisheated
For illustration purpose only
theembossingstartstomeltawayexposingashiny
bitumensurface.
Rollforwardthemembraneandpressfirmlywith Assubsequentrollsareinstalled,heatisapplied
thebootorrolleragainstthesubstratetobond to both the roll and the exposed laps of the
well.thepropaneflameshouldbemovedfrom membranebeingoverlappedonto.Besuretoheat
side to side and up the lap edge while the theentirerollevenlyandnotjustthelapareas,
membraneisslowlyunrolledandadheredtothe withextraconcentrationatthelaps.
underlying surface. Subsequent shift of the roll Caution:Donotovertorchthemembraneasthis
shallbeavoidedafterheatinghasbegun.When willexposethereinforcementandcausedamage
complete, the remaining un-torched membrane toit.
shall be re-rolled and installed in the same
manner.Whenoneendiscomplete,re-rollthe Sealing
opposite end not yet torched, and install in the Heat both the overlaps and use round tipped
samemanner. trowel to seal the overlap. Adequate heat is
confirmedwhenauniformflowofmeltedbitumen
compoundflowsevenlyinabeadthatoozesfrom
theappliedmembrane’sedges.
Excesscompoundshouldbepressedintotheseam
usingaheatedtrowel.Anyun-bondedareasmust
beliftedandre-torched.Donotattempttoreseal
bytorchingthetopsurfaceofthemembrane.
protection
BitupluS Ex should be protected from getting
damagedduetotheongoingsiteactivitiesand
duringbackfilling.Membraneslaidonhorizontal
surfacescanbeprotectedeitherbyacementsand
screed(50mmthick)orbyanasphalticprotection
board (BituBoARD)*. on vertical surfaces the
membranehastobeprotectedwithBituBoARD.
BituBoARD can be fixed on the membrane by
torching the underside of the board, or with a
doublesidedbitumenadhesivetape(BitutApE tS)*.
Please contact our technical service team for
specific requirement.
standards
BitupluS Ex membranesaretestedandconformto
External Corner Details therequirementsofAStManduEAtc2001.
www.henkelpolybit.com
1 BitumastiC/polyseal ps 6 RCC
2 Bituplus Ex 7 Bituplus Ex
3 BituBoaRD 8 polypRimE sB
4 protection screed 9 plain Cement
5
angle Fillet Concrete (pCC)
TDS_Bituplus-Ex_GCC_0514
saFety precautions
Anynakedflameshouldbekeptwellawayfrom
thegascylinders.Whenignitedthetorchshould
bewatchedatalltimes.thetorchshouldnotbe
restedonfinishedroofing.Extremecareshouldbe
takenwhenworkingnearcombustiblematerialsor
itemswhichmightbescorchedbythegasflame.
www.henkelpolybit.com
technical speciFication
PROPERTIES VALUES TEST STANDARDS
product Ex4180 Ex4200
thickness,[mm] 4.0 4.0 DiNEN1849-1
Massperunitarea, 4mm 4.0-4.3 4.0-4.3 DiNEN1849-1
[kg/m2]
Reinforcement(polyester), 180 200 EN29073-1
[g/m2]
Coatingasphalt StyreneButadieneStyrenepolymerModifiedAsphalt
Softeningpoint(R&B),[°C] >110 AStMD36
penetration@25°C,[0.1mm 20-35 AStMD5
tensileStrength(l/t),[N/5cm] 850/650 900/700 DiNEN12311-1
TDS_Bituplus-Ex_GCC_0514
Apartfromtheinformationgivenhereitisalsoimportanttoobservetherelevantguidelinesandregulationsofvariousorganisationsandtradeassociationsaswell
astherespectivestandards.theaforementionedcharacteristicsarebasedonpracticalexperienceandappliedtesting.Warrantedpropertiesandpossibleuseswhich
gobeyondthosewarrantedinthisinformationsheetrequireourwrittenconfirmation.Alldatagivenwasobtainedatanambientandmaterialtemperatureof
+23°Cand50%relativeairhumidityunlessspecifiedotherwise.pleasenotethatunderotherclimaticconditionshardeningcanbeacceleratedordelayed.
theinformationcontainedherein,particularlyrecommendationsforthehandlinganduseofourproducts,isbasedonourprofessionalexperience.Asmaterials
andconditionsmayvarywitheachintendedapplication,andthusarebeyondoursphereofinfluence,westronglyrecommendthatineachcasesufficienttestsare
conductedtocheckthesuitabilityofourproductsfortheirintendeduse.legalliabilitycannotbeacceptedonthebasisofthecontentsofthisdatasheetoranyver-
baladvicegiven,unlessthereisacaseofwilfulmisconductorgrossnegligenceonourpart.thistechnicaldatasheetsupersedesallpreviouseditionsrelevantto
thisproduct.
ManufacturedinG.C.C.
Henkelpolybitindustriesltd. Henkelpolybitindustriesltd.
p.o.Box293,ummAlQuwain,uAE p.o.Box2230,AlKhobar31952,KSA
tel:+97167670777,Fax:+97167670197 tel:+966138084061/62,Fax:+966138121164
henkelpolybit@henkelpolybit.com dammam@henkelpolybit.com