OLT -A

(OVER LOAD TRANSMITTER)

GENERAL SPECIFICATIONS
* 110-440 Volt Supply
* 5 Digit 7 segment red Led display
* 5 pcs status LED
* 4 push buttons,
* 4 pcs general use 3 pin (NC/NO/Com) relays
* High resolution ∑-∆ ADC
* Min 70Ω loadcell input ,
* RS232C (PC-PLC-Printer- External display),
* 0~5 V / Analog output.
* RF Communication (Optional)

BUTTON FUNCTIONS
ZERO Zeroing button, for zeroing the weight. Used for: Down button
AŞAĞI in menus, decreasing the values, changing between
TUŞ parameters.
FONKSİYON Function button., Used for ;Entering parameter menu, up
YUKARI button in menues, increasing the values, changing between
TUŞ parameters.
ESC Escape button. Used for ; shifting the value to next digit and
YAZDIR add a zero at the and in parameters. Printer button while in
TUŞ communication mode.
ENTER Enter button. Entering calibration, confirming inputted values,
TUŞU saving and going through next steps in menues.

Table 1.1
St Stable led Constantly lights up when weighing data is stable,
otherwise blinks.
Sp1 Relay 1 Lights up and switches the relay outputs if relay 1 set value
Status LED has reached
Sp2 Relay 2 Lights up and switches the relay outputs if relay 2 set value
Status LED has reached
Sp3 Relay 3 Lights up and switches the relay outputs if relay 3 set value
Status LED has reached
Sp4 Relay 4 Lights up and switches the relay outputs if relay 4 set value
Status LED has reached
Table1.2

MENU PARAMETERS & USAGE STEPS


Device will be ready for about 5-10 seconds after power up. Wait a while for it to
enter the weighing mode.
Press ENTER to enter CALIBRATION menu.
Pres F to enter PARAMETERS menu.

CALIBRATION :
After entering the calibration menu “ CAL x” will appear on the display. You can select
between different calibration options with up and down buttons or quit with esc button. Enter
will let you pass the next steps.
Kalibrasyon menusüne girdikten sonra ekranda "Cal x) yazacaktır.Kullanılacak olan
Kalibrasyon yöntemi "Yukarı" ve "Aşağı" ok buton tuşları yardımıyla seçilir ve enter tuşuna
basarak onaylanır.
NO DISPLAY OPTION DESCRIPTION
1 "Cal 1" Calibration
with
refference
load
2 Milivolt
"Cal 2" calibration

"CAL 1" CALIBRATION WITH REFFERENCE LOAD


To make a calibration with a refference load , please follow the steps below.

NO DISPLAY OPTION DESCRIPTION KEY BINDINGS


1 "Cal 1" (refference Load calibration "ENTER"
load ) mode. "ESC"

2 Not currently in "UP"


use please move to "DOWN"
next step. "ENTER"

3 1-2-5-10-20-50-100- Divisional "UP"


200 value "DOWN"
"ENTER"
4 "0" Decimal point "UP"
"0.0" adjustment "DOWN"
"0.00" "ENTER"
"0.000"
5 Press up and enter Maximum "UP"
simontaniously capacity "ENTER"

6 Use up, down end Entering the "UP"


esc buttons to capacity "DOWN"
determine the "ENTER"
capacity
7 Wait 3 seconds to Calibration first Press ZERO and wait
wanish ZERO on the step readings. a bit, then add your
display. refference load

8 Wait 2 seconds to Calibration first


stabilisation on the step readings. “ENTER”
display.

9 Entering the Use up, down end "YUKARI"


refference weight esc buttons to "AŞAĞI"
value determine the "ESC"
capacity "ENTER"
10 Saving screen Your data is After 3 seconds it will
saving. Please wait return to weighing
a while mode.
CALIBRATION
HAS BEEN DONE!

"CAL 2” MILIVOLT CALIBRATION

You can calibrate OLT-A with your load cells output value

NO DISPLAY OPTIONS DESCRIPTION KEY BINDINGS


1 "CAL 2" Calibration with "ENTER"
milivolt load cell output "ESC"
Calibration
2 Loadcell Enter your load "ENTER"
Capacity cells capacity. "ESC"

3 Loadcell Rated Enter the output "ENTER"


Output value of your "ESC"
load cell.

4 Loadcell Press enter to "ENTER"


Zero Calibration finish the "ESC"
calibration.
PARAMETERS

NO DISPLAY OPTIONS DESCRIPTION HARDWARE

1 SET 1 You can adjust 4 pcs 3 output


RELAY SET the relays here relay.
PARAMETERS
2 SET 2 You can set an
ANALOG OUTPUT propotional 0-5V
analog output
according to
ANALOG
current load OUTPUT
3 COMUNNICATION Setting baud PC / PLC
SETTINGS rate and device PRINTER /
choices. EXTERNAL
DISPLAY
4 WEIGHING filter intensity
FILTER SETTINGS settings can be
made

SET 1 (RELAY SETTINGS)


You can set 4 pcs relay according to set values. Follow these steps below to adjust the
relay outputs.

NO DISPLAY OPTIONS DESCRIPTION KEY BINDINGS


1 RELAY SET ENTER
PARAMETERS

2 RELAY -1 "ENTER"
"ESC"

3 RELAY -2 "ENTER"
"ESC"

4 RELAY -3 "ENTER"
"ESC"

5 RELAY -4 "ENTER"
"ESC"

When you press enter, display will show you current set value of the selected relay.
Please use up,down, and esc buttons to determine the set value and press ENTER to finish the
settings.
SET 2 (ANALOG OUTPUT SETTINGS)

You can adjust an analog output according to your capacity and current load
Please follow these steps

NO DISPLAY OPTIONS DESCRIPTION KEY BINDINGS


1 ENTER

2 "An.CAP" Determines "ENTER"


Analog output upper limit of "ESC"
5V analog
capacity output.
3 Capacity value Enter your "UP"
capacity with "DOWN"
up,down,esc
buttons.
"ESC"
"ENTER"

SET 3 (COMMUNICATION SETTINGS)

OLT-A has built in RS232-RS232c features. Baud rate, device selections can be set
through this menu by following these steps.

NO DISPLAY OPTIONS DESCRIPTION KEY BINDINGS


1 "ENTER"
COMMUNICATION "ESC"
SETTINGS

2 baud.1=19200 5 different baud "YUKARI"


baud.2=9600 rate settings are "AŞAĞI"
available
baud.3=4800 "ESC"
baud.4=2400 "ENTER"
baud.5=1200
3 Com.1=off Device "ESC" YE
Com2=Ext. Disp. selections. BASARAK
Com3=Printer PARAMETRE
Com4=Continus data MENÜSÜNE
ÇIKINIZ.
SET 4 (WEIGHING SETINGS)

NO DISPLAY OPTIONS DESCRIPTION KEY BINDINGS


1 "ENTER"
"ESC"

2 Currnetly off "ENTER"


Not currently active mode
Please move to
next step

3 FLtr.1= Weak Filter intensity "ESC" YE


FLtr.2= settings BASARAK
6 level of
FLtr.3= intensity are
PARAMETRE
FLtr.4= Normal available MENÜSÜNE
FLtr.5= ÇIKINIZ.
FLtr.6=Strong