Vous êtes sur la page 1sur 5

ALARM SERIVCE USING AMOS

PROCEDURE
 Launch MOshell against the specified Network Element
 Retrieve a list of all alarms currently active on the node
using the command:
al

al | grep "Crit "

al | grep ­c "Maj "

 Show all details for an alarm using the command:


ala 

 To print all alarms chronologically use the following


command: alt

 To see more detailed information:


alat

 To print acknowledged and unacknowledged


alarms
alk
alak

Note: For a complete description of the al command,


type h al at the MOshell prompt

• cab - Prints MP/BP HW info and LED status, MP


temperature, and COREMGR status.
• cabl - Same as cab but plus MP/BP processor
load.

FILE SYSTEM
In order to list a file system type the following at the
AMOS prompt
cd /d/configuration
ftree
To place files from the OSS UNIX file system onto the
Network
Elements file system:
ftput[c] localfile/localdir 
[remotefile/remotedir]

CONFIGURATION VERSION
Cvls: Displays both the current CV information and
CV list
cvcu, cvmk, cvset, cvms, cvget

Note: If the OSE shell command cv mk is used to create a CV (instead


of
cvmk or cvms), the CV attributes will not contain the UpgradePackage
reference which means that the CV will not be deleted when the
UpgradePackage MO is removed. If there are CVs left on the Network
Element without their corresponding UpgradePackage and the Network
Element is restarted on one of these CVs, there is a high risk that the
Network Element will start performing cyclic restarts. To avoid this
situation it is recommended to always use the AMOS command cvmk
or cvms when creating CVs since the UpgradePackage reference will
then automatically be included in the CV attributes.

HARDWARE/SOFTWARE INVENTORY
Displays the complete HW/SW inventory:

inv[hr]

LICENCE:
inv

Integration unlock:

license iu activate

SOFTWARE UPGRADE
1-
confb+

gs+

cr
SwManagement=1,UpgradePackage=CXP9016868_R3AF
12

169.254.1.2 #ftpServerIpAddress

/CXP9016868%1_R3AF12.xml
#upFilePathOnFtpServer

rbs #user

rbs #password

lset
SwManagement=1,UpgradePackage=CXP9016868_R3AF
12$ maxTimeBetweenUpgradeEvents 1

lset
SwManagement=1,UpgradePackage=CXP9016868_R3AF
12$ sendEvents false

lset
SwManagement=1,UpgradePackage=CXP9016868_R3AF
12$ userLabel

confb-

gs-

2-

pr UpgradePackage

/ read the proxy number: xxx: proxy of


upgradePackage=CXP9016868_R3AF12

acc xxx nonBlockingInstall

/ Activate Filezilla ftp server

pollu

/ After installation completion


pr upgrade

acc xxx rebootNodeUpgrade

pollu

cvms afterupgrade

Vous aimerez peut-être aussi