Vous êtes sur la page 1sur 2

PC Since 1977

Since 1977

Used by all leading Transformer Manufacturers, Utilities and various industries for over 39 years.
NEW
PC171 ITMDTI / PC252 ITMDTI
PC171 ITMDTI & PC252 ITMDTI are used for measurement of Oil and Winding
Temperature of Large, Medium Power & Distribution Transformers with remote
transmission and display of measured temperature. It comprises of our Model PC-171 &
PC252 Oil Temperature Indicator / Winding Temperature Indicator fitted with an Integrated
Programmable Signal Transmitter that converts the measured temperature to a robust
2.wire, 4-20mA dc current output for reliable transmission to a remotely mounted Digital
Temperature Indicator DTI. DTI provides 24 V dc Power Supply to the Integrated Signal
Transmitter and receives the 4-20mA input for display on the same 2 wires.

24 V dc

4-20mA dc lSaves marshalling box space –


no separate Resistance to
current convertor unit.

lSaves wiring costs – Only 2 wires


are required for 24 V dc power
24 V dc
supply as well as 4-20mA dc
4-20mA dc
current output.

lMeasurement Output - Signal


transmission as current mode 4-
24 V dc 20 mA dc is much more reliable,
Robust and less susceptible to
4-20mA dc
EMI than Voltage mode signal
transmission.

lSuperimposed electro-magnetic interference voltage, COMMON IN HIGH


VOLTAGE ENVIRONMENTS LIKE SUBSTATIONS, affects the voltage mode
transmission signal, but 4-20 mA dc SIGNAL HAS BEEN PROVEN TO BE
UNAFFECTED BY SUCH EMI.

lHERMETICALLY SEALED electronics of signal transmitter ensures better long


term reliability since this prevents humidity & moisture from affecting the
electronics.

lThis Unique design leverages the proven reliability of our model PC171 / Model
PC252 Oil &Winding temperature measuring system that has been in operation in
the field for over 30 years with various reputed customers in India and globally
including PGCIL, NTPC, NPC, BARC, various State Electrical Utilities / SEB's etc.
RTDHM Remote Oil & Winding Temperature
Transmitters/Indicators
RTDHMDTI is an Integrated Temperature Monitor used for measurement of Oil &
Winding Temperature of Power & Distribution Transformers with remote transmission
and display.It comprises of our Pt100 sensors fitted with an Integrated Programmable
Universal Temperature Transmitter that converts the measured temperature to a robust
2 wire, 4-20mA dc current output for reliable transmission to a remotely mounted Digital
Temperature Indicator DTI. DTI provides 24 V dc Power Supply to the Integrated Signal
Transmitter and receives the 4-20mA input for display on the same 2 wires.

24 V dc

4-20mA dc

lSaves marshalling box space – no separate Resistance to current convertor unit.

lSaves wiring costs – Only 2 wires are required for 24 V dc power supply as well as
4-20mA dc current output.

lThis Unique design leverages the proven reliability of our Pt100 RTD that has been
in operation in the field for over 39 years with various reputed customers in India
and globally including PGCIL, NTPC, NPC, BARC, various State Electrical Utilities
/ SEBs etc.

24 V dc

4-20mA dc

lMeasurement Output - Signal transmission as current mode 4-20 mA dc is much


more reliable, Robust and less susceptible to EMI than Voltage mode signal
transmission.

lSuperimposed electro-magnetic interference voltage, COMMON IN HIGH


VOLTAGE ENVIRONMENTS LIKE SUBSTATIONS, affects the voltage mode
transmission signal, but 4-20 mA dc SIGNAL HAS BEEN PROVEN TO BE
UNAFFECTED BY SUCH EMI.

lHERMETICALLY SEALED electronics of signal transmitter ensures better long


term reliability since this prevents humidity & moisture from affecting the
electronics.

PERFECT CONTROLS
PC 7, North Road, West C.I.T. Nagar, Chennai-35, India.
Ph: 044-24330387 Email:sales@perfectcontrols.com
Since 1977
Web: www.perfectcontrols.com