Vous êtes sur la page 1sur 2

Industrial

Enclosures
1. ¼” per foot slope in the single slope roof system
2. Structural “I” beam
3. Optional louvers
4. Optional wood blocking
5. Optional specially braced wall panel
6. Optional metal commercial door
7. 20 gauge galvanized Z base flashing
8. Angle clip anchors
9. Mesa profile (polar white or sand tan)
10. Standard construction meets high seismic criteria

Industrial Enclosures are designed for permanent or temporary sheltering of


sensitive equipment and instruments from dust and temperature extremes.

A Kysor Panel Systems building, with its solid core urethane insulation, provides an ideal cost
effective shelter for industrial, commercial scientific and environmental purposes. Control of temperature,
dust and noise is positively maintained for sensitive, high-technology equipment while providing a
comfortable and clean work environment for service and monitoring personnel.

Kysor Panel Systems buildings are expandable. The modular wall and roof sections are highly durable
and can be rearranged, added to, or even moved to a new location.
Listings and Labels Testing and Certifications
Sanitation State Licensed Contractor
National Sanitation Foundation (NSF) - Standard 7 Alaska Louisiana South Carolina
Required by many Health Departments and specified by Food Consultants Alabama Mississippi Tennessee
US Department of Agriculture (USDA) Acceptance Arizona Nevada Utah
Required for meat and poultry processing facilities Arkansas North Carolina Virginia
Electrical California North Dakota Washington
UL 471- UL Standard for Safety-Refrigerators/Freezers Florida Oregon West Virginia
NFPA 70 – The National Electric Code Georgia
Required by Building Departments for pre wired electrical (This license is not required in all states – out of 50 states contacted
CSA C22.2 – CAN/CSA Refrigeration Equipment 29 did not require licenses.)
Required for all pre wired electrical in Canada
State Certified Manufacturer Of Modular/Component Structures
Flammability This certification is required to obtain and apply State Labels to
ASTM E-84, ANSI 2.5, NFPA 255, UBC 8-1 – Surface Burning pre-assembled Environmental Enclosures prior to shipping into the state
Characteristics - Core
Arizona Massachusetts Oregon
ASTM D-1929 – Ignition Properties
California Minnesota Rhode Island
Required by Chapter 26 of the IBC for plastic insulation in
Colorado Missouri South Carolina
sprinklered buildings
Connecticut New Jersey Tennessee
UL 723 – Surfaced Burning Characteristics – Finished panels
Florida New Mexico Virginia
Specified by Food Consultants
Georgia North Dakota Washington
CAN/ULC S-102 – Surface Burning Characteristics – Core and
Louisiana Ohio Wisconsin
Finished Panel
Maryland
CAN/ULC S-127 – Corner Wall Flammability
CAN/ULC S-138 – Fire Growth and Damageability – Room Code Compliance Testing
Required to sell product in Canada The International Building Code required this testing be
FM 4471 (ASTM E-108) – Fire test of roof panels done by a nationally recognized third party testing agency.
FM 4820 - Surface Burning Characteristics - Core This testing is not acceptable if conducted by the
FM 4880 – Fire Rating of Insulated Wall & Ceiling Panels - Room manufacturer or the foam insulation supplier.
FM ISO 1716 – Heat Combustion ASTM C-272 - Water absorption
FM ASTM D-482 – Ignition Residue ASTM C-273 – Shear Strength
Factory Mutual Approval allows use without sprinklers and without ASTM C-393 – Flexural Strength
Thermal Barriers ASTM C-518 – Thermal Transmission
UPITT Protocol – Toxicity ASTM D-635 – Horizontal Burning
Required to sell product in New York City ASTM D-1621 – Compressive Properties
NFPA 286 – Fire Contribution - allows panels without sprinklers and ASTM D-1622 – Density
without Thermal Barriers ASTM D-1623 – Tensile Strength
ASTM D-2126 – Dimensional Stability
Approvals ASTM D-2294 – Adhesion
ASTM D-2856 – Open Cell Content
Miami-Dade County -Florida Building Code – Hurricane Winds ASTM E-72 – Compressive Load, Transverse Load and Racking Load
Required for outdoor installation in Florida ASTM E-90 – Acoustic Performance
City of Los Angeles – Municipal Building Code – Seismic Forces ASTM E-331 – Water penetration of exterior walls
Required for indoor & outdoor installation in Los Angeles ASTM E-661 – Concentrated and Impact Loads
City of Houston – Houston Building Code – Fire & Structural
Cyclic Racking (SEAOSC) Required by the International Building Code
Required for indoor & outdoor installation in Houston
for High Seismic Zones
City of New York – Material & Equipment Acceptance - Toxicity
CCRR - Code Compliance Research Report – equivalent
Required for indoor & outdoor installation in New York City
to ICC evaluation. This report provides National Product
State of California – Licensed Thermal Insulation Manufacturer
Recognition for Code Compliance.
Required to sell product in California
State of Oregon – Prefabricated Structures
Required to sell product in Oregon
State of Wisconsin – Material Approval
Required to sell product in Wisconsin Note: All of the above is subject to change and update by Kysor Panel Systems. REV:20090420

Phone 800-633-3426 | Fax 817-281-5521 | www.kysorpanel.com