DATA:

C 20/25
Bst 500S / Bst 500 M
g = 5 kN/m2
q = 2.5 kN/m2
ds = 15 cm
Cnom= 1.5 cm

g = γ * g = 1.35 * 5 = 6.75 kN/m2

q = γ * q = 1.5 * 2.5 = 3.75 kN/m2

DISTANCE TO THE CENTER OF REINFORCEMENT


d1 = Cnom + ɸ/2 = 1.5 cm + 1cm/2 = 2 cm

d' = ds – d1 = 15cm – 2 = 13 cm

FIELD

µ = Meds / b * d2 * fcd

µ = 1430 kNcm / 100 cm * 132 * 1.33

µ = 1430 / 22477

µ = 0.06

fcd = α * fc / γc fyd = fsteel / γsteel

fcd = 1 * 20 Mpa / 1.5 fyd = 500 Mpa / 1.15

fcd = 1.33 kN/cm2 fyd = 434.78kNm = 43.478 kN/cm2


Areq = Meds / ζ * d * fyd

Areq = 1430 kNcm / 0.967 * 13 * 43.478

Areq = 1430 / 546.56

Areq = 2.616 cm2/m'

-From table, it has been taken the value : ζ = 0.967, need for calculation of
required area.

So, provided mesh for field is:

PROVIDED: R 335 ; Bst 500 M


req a,s = 2.616 cm2/m' < prov a,s = 3.35 cm2/m'

SUPPORT

µ = Meds / b * d2 * fcd

µ = 2427 kNcm / 100 cm * 132 * 1.33

µ = 2427 / 22477

µ = 0.11

Areq = Meds / ζ * d * fyd

Areq = 2427 kNcm / 0.940 * 13 * 43.478

Areq = 2427 / 531.30

Areq = 4.56 cm2/m'

-From table, it has been taken the value : ζ = 0.940, need for calculation of
required area for support.

So, provided mesh for field is:

PROVIDED: R 524 ; Bst 500 M


req a,s = 4.56 cm2/m' < prov a,s = 5.24 cm2/m'