Series LFII Dry-Type Residential Sprinklers

Recessed Pendent 4.9 K-factor


TFP460

Horizontal Sidewall and 4.4 K-factor


WHY USE COMMERCIAL Recessed Horizontal Sidewall TFP461
DRY SPRINKLERS IN
RESIDENTIAL SYSTEMS?

Introducing RAPID RESPONSE


Dry-Type Residential Sprinklers

An industry first for


◆◆
residential designs
For use in wet pipe, dry pipe,
◆◆
and preaction systems
All models available in white,
◆◆
chrome, or brass finishes

The RAPID RESPONSE Series LFII


Dry-Type Residential Sprinklers are
UL Listed and designed for use in
residential occupancies per NFPA
13D, 13R, and 13. The sprinklers can
be installed in wet pipe, dry pipe,
or preaction systems and have
undergone special testing at UL
to meet UL1626 test criteria. These
TECHNICAL DATA
sprinklers are ideal for installation in
basements, garages, or portions of Recessed Pendent, TY2235
homes, apartments, dormitories, or
Approvals: UL Listed
hotels where sprinklers drop into or
from unheated areas. Maximum Working Pressure: 175 psi (12,1 bar)
Discharge Coefficient: K= 4.9 GPM/psi1/2 (70,6 LPM/bar1/2)
The Series LFII Dry-Type Residential
Inlet Thread Connection: 1-inch NPT
Sprinklers include the Recessed
Pendent, Horizontal Sidewall, and Temperature Rating: 155°F (68°C);
Recessed Horizontal Sidewall. 175°F (79°C) for Wet Pipe Systems only,
Finishes: ( Sprinkler) White Polyester Coated, Chrome-Plated, or Natural Brass;
Each sprinkler is available in white, (Recessed Escutcheon) White, Chrome, or Brass.
chrome, or brass finishes and has a
temperature rating of 155°F (68°C). Horizontal Sidewall and
Recessed Horizontal Sidewall, TY2335
Additionally, the Recessed Pendent
is listed for 175°F (79°C) in wet pipe Approvals: UL Listed
systems. Maximum Working Pressure: 175 psi (12,1 bar)
Discharge Coefficient: K= 4.4 GPM/psi1/2 (63,4 LPM/bar1/2)
Inlet Thread Connection: 1-inch NPT
Temperature Rating: 155°F (68°C)
Finishes: White Polyester Coated, Chrome-Plated, or Natural Brass

Refer to Technical Data Sheets TFP460 and TFP461 for complete descriptions of all listing criteria, design parameters,
installation instructions, care and maintenance guidelines, and warranty information.
Series LFII Dry-Type Residential Sprinklers

Recessed Pendent (TY2235)


WET PIPE
Minimum Flow and
DRY PIPE
Minimum Flow and
Recessed Pendent
Residual Pressure for Residual Pressure for Assembly
Maximum Maximum Horizontal Ceilings Horizontal Ceilings
Coverage Spacing (Maximum 2-inch Rise for (Maximim 2-Inch Rise for
(TY2235)
Area Ft. (m) 12-Inch Run) 12-Inch Run) SPRINKLER FITTING
Ft. x Ft. (REFER TO DESIGN
CRITERIA SECTION)
(m x m) 155°F (68°C)
155°F (68°C) FACE OF
175°F (79°C) SPRINKLER
FITTING
12 x 12 12 13 GPM (49,2 LPM) 13 GPM (49,2 LPM)
(3,7 x 3,7) (3,7) 7.0 psi (0,48 bar) 7.0 psi (0,48 bar)
ORDER LENGTHS:
3-3/4" to 24"
14 x 14 14 14 GPM (52,9 LPM) 14 GPM (52,9 LPM) (95,3 to 609,6 mm)
(4,3 x 4,3) (4,3) 8.2 psi (0,57 bar) 8.2 psi (0,57 bar) IN 1/4" (6,4 mm) 2-1/4" DIA.
INCREMENTS (57,2 mm)
16 x 16 16 15 GPM (56,8 LPM) 15 GPM (56,8 LPM) FACE OF
(4,9 x 4,9) (4,9) 9.4 psi (0,65 bar) 9.4 psi (0,65 bar) CEILING

18 x 18 18 18 GPM (68,1 LPM) 18 GPM (68,1 LPM)


(5,5 x 5,5) (5,5) 13.5 psi (0,93 bar) 13.5 psi (0,93 bar)
2-7/8" DIA.
20 x 20 20 21 GPM (79,5 LPM) 21 GPM (79,5 LPM) 1-3/8" ± 1/8" (73,0 mm)
(34,9 ± 3,2 mm)
(6,1 x 6,1) (6,1) 18.4 psi (1,3 bar) 18.3 psi (1,3 bar)

Horizontal Sidewall and Recessed Horizontal Sidewall (TY2335)


Maximum Minimum Flow and Residual Pressure for Horizontal Ceiling, 155°F (68°C) Recessed Horizontal
Coverage
Area
Maximum Top-of-Deflector to Ceiling: Top-of-Deflector to Ceiling: Sidewall Assembly
Spacing 4 to 6 Inches (100 to 150 mm) 6 to 12 Inches (150 to 300 mm)
Width x Length
Ft. x Ft.
Ft. (m) (TY2335)
(m x m) WET PIPE DRY PIPE WET PIPE DRY PIPE ORDER LENGTHS:
3-3/4" to 24" (95,3 to 609,6 mm)
IN 1/4" (6,4 mm) INCREMENTS
12 x 12 12 13 GPM (49,2 LPM) 13 GPM (49,2 LPM) 15 GPM (56,8 LPM) 15 GPM (56,8 LPM) 2-3/16" ± 1/4"
(55,6 ± 6,4 mm)
(3,7 x 3,7) (3,7) 8.7 psi (0,60 bar) 8.7 psi (0,60 bar) 11.6 psi (0,80 bar) 11.6 psi (0,80 bar) FACE OF FACE OF
5/16"
SPRINKLER MOUNTING (7,9 mm)
14 x 14 14 14 GPM (53,0 LPM) 16 GPM (60,6 LPM) 15 GPM (56,8 LPM) 16 GPM (60,6 LPM) FITTING SURFACE
(4,3 x 4,3) (4,3) 10.1 psi (0,70 bar) 13.2 psi (0,91 bar) 11.6 psi (0,80 bar) 13.2 psi (0,91 bar)
2-7/8" DIA.
16 x 16 16 17 GPM (64,3 LPM) 17 GPM (64,3 LPM) 19 GPM (71,9 LPM) 19 GPM (71,9 LPM) (73,0 mm)
(4,9 x 4,9) (4,9) 14.9 psi (1,03 bar) 14.9 psi (1,03 bar) 18.6 psi (1,28 bar) 18.6 psi (1,28 bar)
16 x 18 16 19 GPM (71,9 LPM) 20 GPM (75,7 LPM) SPRINKLER FITTING
N/A N/A (REFER TO DESIGN CENTERLINE 1-3/4" DIA.
(4,9 x 5,5) (4,9) 18.6 psi (1,28 bar) 20.7 psi (1,43 bar) CRITERIA SECTION) OF WATERWAY (44,5 mm)

16 x 20 16 25 GPM (94,6 LPM) 25 GPM (94,6 LPM)


N/A N/A
(4,9 x 6,1) (4,9) 32.3 psi (2.23 bar) 32.3 psi (2.23 bar)

ORDERING PROCEDURES
Contact your local distributor for availability. When placing an order, indicate the full product name and part number.
LFII Dry-Type Residential Sprinklers
Recessed Pendent, K= 4.9 and Horizontal Sidewall and Recessed Horizontal Sidewall, K = 4.4

P/N 63 – XXX – X – XXX

TEMPERATURE
SPRINKLER RECESSED
RATING
FINISH ESCUTCHEON FINISH ORDER LENGTH
(EXAMPLES)
1 155°F (68°C)
9 Chrome Plated Chrome
055 5.50”
175°F (79°)
2 White Polyester
(Wet Pendent Only) 4 White
Coated 082 8.25”

MODEL/SIN 2 Natural Brass Brass Plated


180 18.00”
Pendent
10 TY2235
with Recessed Escutcheon 187 18.75”
Sprinkler Wrenches
Horizontal Sidewall
12 TY2335 W-Type 6 Wrench 56-000-6-387
with Recessed Escutcheon 240 24.00”
Horizontal Sidewall W-Type 7 Wrench
13 TY2335 56-850-4-001
without Escutcheon Recessed

Tyco Fire Suppression & Building Products


Technical Services
Phone: 1-800-381-9312 Fax: 1-800-791-5500
www.tyco-fire.com
Copyright © 2010 Tyco Fire Suppression & Building Products. All rights reserved. TF-2010003