P.O. ENGINEERING DEPT.

MISCELLANEOUS
ENGINEERING INSTRUCTIONS TIME
B 1303

ELECTRICAL CLOCKS - PULSE TYPE


Clock-unit, GMT 35

1. General - Clock-unit, GMT 35 is used in of the unit should be requisitioned separately and fitted
conjunction with a master clock (Clock No. 36) to locally as indicated on Dgm. GMT 35. Resistor R2 is
facilitate the distribution of pulses at offices where 30 required to limit the current through relay AR to 10 mA
second pulses only are required or where the 30 second when the unit is used with voltages higher than 24V.
pulse clock capacity of an existing Clock-unit, GMT 34
must be exceeded. The unit is designed for 24V 4. Large installations - When the number of pulse
working and is wired to Dgm. GMT 35. The layout of clocks to be installed exceeds the capacity of one unit,
the apparatus is shown on Drg. P/T 79 and installation an additional Clock-unit, GMT 35 should be provided
details are given in B 3301. and connected to the first unit by wiring in parallel the
pulse relays connected to tags 13. Tags 2, 3 and 11 of
2. Description - The unit, which is wired for its the additional unit should be left disconnected.
ultimate capacity, is fitted initially with sufficient
apparatus to operate twenty 30 second pulse clocks, i.e. 5. When used in conjunction with Clock-unit, GMT
two circuits of ten. The unit has a maximum capacity 34 (see B 1302) the pulse relays should be connected in
for sixty 30 second pulse clocks. parallel, i.e. tag 13 on Clock-unit, GMT 35 should be
connected to tag 5 on Clock-unit, GMT 34. In the
3. Additional apparatus - Resistor R1 and R3 (and additional Clock-unit, GMT 35 tags 2, 3 and 11 should
resistor R2 when required) and additional apparatus for be left disconnected.
increasing the capacity

References: - B 1302, B 3301


(P2)

END