Vous êtes sur la page 1sur 3

Design of Isolated footing

FOOTING 2B
Concrete Grade M 20.00
Steel Grade Fe 500.00
Bearing Capacity 150.000 KN/m2
Pu 419.213 KN
Column size l 0.304 m 304.00 mm
b 0.304 m 304.00 mm

1.00 Footing Size


Self Weight of Column 41.921 KN
Total Pu 461.135 KN

Adopt square footing


Area 3.074 m2
Length of footing 1.753 m
Adopted Length 1.829 m 6.00 ft
1829.000 mm
Actual pressure BCS 187.974 KN/m2

2.00 Depth of Footing


Maximum BM 99.945 KN-m
depth check d= 192.969 mm
d= 289.454 mm
407.310 mm adopted
d= 0.407 m
Effective cover 50.000 mm
Overal depth D= 457.310 mm

3.00 Calculation of reinforcement


Max.moment= 0.87fyAst(d-(Ast*fy/fck*B))
Ast= 585.11 mm2
Min. area of steel= 1003.70 mm2

dia of bar 12.00 mm Area= 113.10 mm2


spacing 206.09 mm
Spacing provided 152.40 mm
Providing 12.00 mm @152.4 c/c both ways
Area of steel= 1357.316 mm2

% of steel = 0.182 %

4.00 Check for shear


oneway shear
SF 122.116 KN
Nominal shear stress 0.146 N/mm2

Design Shear strength 0.306 N/mm2 table 19


for D= 457.310 mm
k= 1.000
Design Shear strength 0.306 N/mm2 ok

5.00 Check for two way shear


Shear force at critical section 533.712 KN

punching shear resisted by tp*area


tc= 1.12 N/mm2 page 59
equating with two way shear
tp= 0.46 N/mm2 ok

providing effective depth d= 407.310 mm


c= 50.000 mm
D= 457.310 mm

6.00 Check for development length


Ld= 679.69 mm is 456 page 42,43
Ld available= 718.50 mm
ok