Vous êtes sur la page 1sur 576

ZXG10-BSS

Base Station Subsystem Operation Manual


(Performance Measurement Counter)

Version 2.95

ZTE CORPORATION
ZTE Plaza, Keji Road South,
Hi-Tech Industrial Park,
Nanshan District, Shenzhen,
P. R. China
518057
Tel: (86) 755 26771900 800-9830-9830
Fax: (86) 755 26772236
URL: http://support.zte.com.cn
E-mail: doc@zte.com.cn
LEGAL INFORMATION

Copyright © 2005 ZTE CORPORATION.

The contents of this document are protected by copyright laws and international treaties. Any reproduction or distribution of
this document or any portion of this document, in any form by any means, without the prior written consent of ZTE
CORPORATION is prohibited. Additionally, the contents of this document are protected by contractual confidentiality
obligations.

All company, brand and product names are trade or service marks, or registered trade or service marks, of ZTE
CORPORATION or of their respective owners.

This document is provided “as is”, and all express, implied, or statutory warranties, representations or conditions are
disclaimed, including without limitation any implied warranty of merchantability, fitness for a particular purpose, title or non-
infringement. ZTE CORPORATION and its licensors shall not be liable for damages resulting from the use of or reliance on
the information contained herein.

ZTE CORPORATION or its licensors may have current or pending intellectual property rights or applications covering the
subject matter of this document. Except as expressly provided in any written license between ZTE CORPORATION and its
licensee, the user of this document shall not acquire any license to the subject matter herein.

The contents of this document and all policies of ZTE CORPORATION, including without limitation policies related to support
or training are subject to change without notice.

Revision History

Date Revision No. Serial No. Description


30/07/2006 R1.0 Sjzl20060779 English – For Customers
ZTE CORPORATION
Values Your Comments & Suggestions!
Your opinion is of great value and will help us improve the quality of our
product documentation and offer better services to our customers.

Please fax to: (86) 755-26772236; or mail to Publications R&D


Department, ZTE CORPORATION, ZTE Plaza, A Wing, Keji Road South,
Hi-Tech Industrial Park, Shenzhen, P. R. China 518057.

Thank you for your cooperation!

Document ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Management


Name Counters)
Product Document
V2.95 R1.0
Version Revision Number
Equipment Installation Date

Presentation:
(Introductions, Procedures, Illustrations, Completeness, Level of Detail, Organization,
Appearance)
… Good … Fair … Average … Poor … Bad … N/A

Your evaluation Accessibility:


of this
(Contents, Index, Headings, Numbering, Glossary)
documentation
… Good … Fair … Average … Poor … Bad … N/A

Intelligibility:
(Language, Vocabulary, Readability & Clarity, Technical Accuracy, Content)
… Good … Fair … Average … Poor … Bad … N/A

Please check the suggestions which you feel can improve this documentation:
… Improve the overview/introduction … Make it more concise/brief
… Improve the Contents … Add more step-by-step procedures/tutorials
… Improve the organization … Add more troubleshooting information
… Include more figures … Make it less technical … Add more examples
Your
suggestions for … Add more/better quick reference aids … Add more detail … Improve the index
improvement … Other suggestions
of this ___________________________________________________________________________
documentation
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
# Please feel free to write any comments on an attached sheet.

If you wish to be contacted regarding your comments, please complete the following:
Name Company
Postcode Address
Telephone E-mail
This page is intentionally blank.
Contents

About this Operation Guide .......................................................... xi


Purpose of this Operation Guide...............................................................xi
Typographical Conventions.....................................................................xiii
Mouse Operation Conventions................................................................xiv
Safety Signs..............................................................................................xv
How to Get in Touch................................................................................xvi
Customer Support ................................................................................................xvi
Documentation Support ........................................................................................xvi

Chapter 1........................................................................................ 1

Key Performance Indicators.......................................................... 1


Network Performance Measurement ........................................................1
KPI Counters..........................................................................................................1
KPI Counters Explanation ........................................................................................5

Chapter 2...................................................................................... 39

BTS Measurement ........................................................................ 39


Power Control Measurement .................................................................. 39
Power Control Counters......................................................................................... 40
Power Control Counters Explanation....................................................................... 41
TRX Service Measurement ...................................................................... 49
TRX Service Counters ........................................................................................... 50
TRX Service Counters Explanation.......................................................................... 52
Paging Messages Measurement ............................................................. 71
Paging Messages Measurement Counters................................................................ 71
TRX Basic Measurement ......................................................................... 71
TRX Basic Measurement Counters.......................................................................... 72
TRX Power &Temperature Measurement............................................... 72
TRX Power & Temperature Measurement Counters.................................................. 72
TRX Power & Temperature Measurement Counters Explanation ................................ 72
Chapter 3...................................................................................... 75

Wireless Channels........................................................................ 75
Channels Measurement........................................................................... 75
Channels Counters................................................................................................ 75
Channels Counters Explanation.............................................................................. 77

Chapter 4...................................................................................... 87

Random Access ............................................................................ 87


Random Access Measurement................................................................ 87
Random Access Counters ...................................................................................... 87
Random Access Counters Explanation .................................................................... 88

Chapter 5...................................................................................... 97

SDCCH Measurement ................................................................... 97


SDCCH Counters ...................................................................................... 97
SDCCH Counters Explanation................................................................................. 98

Chapter 6.................................................................................... 107

TCH/F Measurement.................................................................. 107


TCH/F Counters..................................................................................... 107
TCHF Counters Explanation ................................................................................. 112

Chapter 7.................................................................................... 137

Service Access Point Identifier 3............................................... 137


SAPI 3 Introduction .............................................................................. 137
SAPI 3 Counters .................................................................................... 138
SAPI 3 Counters Explanation ............................................................................... 139

Chapter 8.................................................................................... 147

Radio Management Module Measurement................................ 147


RMM Assignment Measurement ........................................................... 147
RMM Assignment Counters.................................................................................. 147
RMM Assignment Counters Explanation ................................................................ 148
RMM Queue Measurement.................................................................... 153
RMM Queue Counters ......................................................................................... 154

Chapter 9.................................................................................... 155

RMM Call Drop Measurement..................................................... 155


RMM Call Drop Counters ....................................................................... 155
Call Drop Counters Explanation............................................................................ 157

Chapter 10.................................................................................. 175

Handover Cause Measurement.................................................. 175


Handover Cause Counters..................................................................... 175
Handover Cause Counters ................................................................................... 175
Handover Cause Counters Explanation ................................................................. 177

Chapter 11.................................................................................. 193

General Handover Measurement............................................... 193


Handover Counters ............................................................................... 193
Handover Counters Explanation ........................................................................... 198

Chapter 12.................................................................................. 241

Synchronization Mode Handover Measurement ....................... 241


Synchronization Mode Counters........................................................... 241
Synchronization Mode Counters Explanation ......................................................... 242

Chapter 13.................................................................................. 245

Paging Message Measurement.................................................. 245


Paging Message Counter....................................................................... 245

Chapter 14.................................................................................. 247

Abis-Interface Signaling ............................................................ 247


Abis-interface Measurement................................................................. 247
Abis-interface Counters ....................................................................................... 247
Abis-interface Counters Explanation ..................................................................... 248

Chapter 15.................................................................................. 259

Resource Availability Measurement .......................................... 259


Resource Availability Counters............................................................. 259
Resource Availability Counters Explanation ........................................................... 260

Chapter16................................................................................... 269

Sub Cell Measurement ............................................................... 269


Sub Cell Counters .................................................................................. 269
Sub Cell Counters Explanation ............................................................................. 271

7
Chapter 17.................................................................................. 287

A-interface Signal Measurement ............................................... 287


BSSAP Message Counters ..................................................................... 287
BSSAP Message Counters Explanation.................................................................. 288
BSSMAP Message Counters .................................................................. 289

Chapter 18.................................................................................. 293

A- Interface Service Measurement............................................ 293


SMM Assignment Counters ................................................................... 293
Assignment Process ............................................................................................ 293
SMM Assignment Counters Explanation ................................................................ 294
SMM Handover in Counters................................................................... 296
SMM Handover in Process ................................................................................... 297
Handover in Counters Explanation........................................................................ 297
SMM Call Drop Counters........................................................................ 300
Call Drop Counters Explanation............................................................................ 300

Chapter19................................................................................... 303

SCCP Connection Measurement................................................. 303


SCCP Connection Counters ................................................................... 303
SCCP Connection Counters Explanation ................................................................ 304

Chapter 20.................................................................................. 307

Terrestrial Resources Measurement ......................................... 307


Trunk Circuit Counters .......................................................................... 307
Trunk Circuit Counters Explanation....................................................................... 307

Chapter 21.................................................................................. 311

TRX LAPD Link Measurement .................................................... 311


LAPD Link Counters............................................................................... 311
LAPD Link Counters Explanation........................................................................... 312

Chapter22................................................................................... 317

Processor Load Measurement ................................................... 317


RMM Load Counters .............................................................................. 317
RMM Load Counters Explanation .......................................................................... 318
Service Load Counter ............................................................................ 319
Service Load Counter Explanation ........................................................................ 319
Usability Measurement Counter ........................................................... 320
Usability Measurement Counter Explanation.......................................................... 320
SMM Load Counters............................................................................... 320
SMM Load Counters Explanation .......................................................................... 321
File System Load Counters.................................................................... 321

Chapter 23.................................................................................. 323

Q3 Module Measurement........................................................... 323


Q3 Module Counters.............................................................................. 323
Q3 Module Counters Explanation.......................................................................... 324

Chapter 24.................................................................................. 333

Q3 Cell and BTS Measurement .................................................. 333


Q3 Cell and BTS Counters ..................................................................... 333

Chapter 25.................................................................................. 335

Adjacent Cell Handover Measurement ...................................... 335


Adjacent Cell Handover Counters......................................................... 335
Intra-MSC Handover........................................................................................... 335
Intra-BSC Handover ........................................................................................... 336
Adjacent Cell Handover Counters Explanation ....................................................... 337

Chapter 26.................................................................................. 345

Phase-3 NMS Measurement for Cell .......................................... 345


Phase-3 NMS Counters.......................................................................... 345
Phase-3 NMS Counters Explanation...................................................................... 347

Chapter 27.................................................................................. 359

TCH/H Measurement ................................................................. 359


TCH/H Counters .................................................................................... 359
TCHH Counters Explanation................................................................................. 364

Chapter 28.................................................................................. 389

Half Rate Statistics..................................................................... 389


HR Measurement Counters ................................................................... 389
HR Measurement Counters Explanation ................................................................ 392

Chapter 29.................................................................................. 413

Reserved Channel Measurement............................................... 413

9
Reserved Channel Counters.................................................................. 413
Reserved Channel Counters Explanation ............................................................... 413

Chapter 30.................................................................................. 417

Packet Switched Service Measurement .................................... 417


PS Basic Measurement Counters .......................................................... 417
PS Basic Measurement Counters Explanation ........................................................ 421
PS Traffic Counters................................................................................ 462
PS Traffic Counters Explanation............................................................................ 466
Network Service Sub layer Counters.................................................... 500
Network Service Sub layer Counters Explanation................................................... 501
BSSGP Layer Counters .......................................................................... 508
BSSGP Counters Explanation ............................................................................... 509
NSE Performance Counters................................................................... 518
NSE Performance Counters Explanation................................................................ 519
Resource Management Counters.......................................................... 529
Resource Management Counters Explanation ........................................................ 530

Appendix A ................................................................................. 541

Abbreviations ............................................................................. 541

Appendix B ................................................................................. 545

Tables ......................................................................................... 545

Appendix C ................................................................................. 547

Figures........................................................................................ 547

Appendix D ................................................................................. 549

Index .......................................................................................... 549


About this Operation Guide

Purpose of this Operation Guide


This guide provides information about the ZXG10-BSS Base Station
Subsystem Counters.

TABLE 1 CHAPTERS SUMMARY

Section Summary
Chapter 1, Basic Measurement This chapter describes definition, description
and calculation formulas of basic measurement
task counters.
Chapter 2, BTS measurement This chapter describes definition, description
and measurement points of BTS performance
measurement counters. BTS performance
measurement includes power control
measurement, carrier service measurement,
paging measurement and carrier frequency-
level basic measurement.
Chapter 3, Cell Wireless Measurement This chapter describes definition, description
and measurement points of cell wireless
measurement counters.
Chapter 4, Wireless Access Measurement This chapter describes definition, meaning and
measurement points of wireless access
measurement counters.
Chapter 5, SDCCH Measurement This chapter describes definition, description
and measurement points of SDCCH
measurement counters.
Chapter 6, TCH/F Measurement This chapter describes definition, description
and measurement points of TCH/F
measurement counters.
Chapter 7, SAPI 3 Measurement This chapter describes definition, description
and measurement points of SAPI 3
measurement. Counters.
Chapter 8, RMM Assignment This chapter describes definition, description
Measurement and measurement points of RMM assignment
measurement counters.
Chapter 9, RMM Call Drop Measurement This chapter describes definition, description
and measurement points of RMM call drop
measurement counters.

Confidential and Proprietary Information of ZTE CORPORATION xi


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Section Summary
Chapter 10, Handover Cause This chapter describes the meanings and
Measurement measurement points of handover cause
measurement counters.
Chapter 11, Handover Common This chapter describes the meanings and
Measurement measurement points of handover common
measurement counters.
Chapter 12, Handover Synchronous This chapter describes the meanings and
Measurement measurement points of handover synchronous
measurement counters.
Chapter 13, Paging Measurement This chapter describes the meanings and
measurement points of paging measurement
counters.
Chapter 14, Abis-interface Signaling This chapter describes the meanings and
Statistics measurement points of Abis-interface signaling
statistics counters.
Chapter 15, Wireless Resource Availability This chapter describes the meanings and
Measurement measurement points of wireless resource
availability measurement counters.
Chapter 16, Sub Cell Related Statistics This chapter describes sub cell related statistics
Measurement measurement counters for second sub cell in
dual frequency cell.
Chapter 17, A-interface Signaling This chapter describes the meanings and
Measurement measurement points of A-interface signaling
statistics measurement counters.
Chapter 18, A-interface Service This chapter describes the measurement of
Measurement Assignment, Call Drop and Handover Statistics
at A-interface.
Chapter 19, SCCP Connection Counters This chapter describes SCCP connection
counters for SCCP messages that are used to
setup an SCCP connection.
Chapter 20, terrestrial Resource Trunk This chapter describes trunk circuit counters for
Circuit Measurement BSC trunk circuits.
Chapter 21, TRX LAPD Link Measurement This chapter describes LAPD link counters for
the TRX LAPD board, which transfers the
signaling messages to its contiguous layers.
Chapter 22, Processor Load Measurement This chapter describes processor load
measurement counters for CPU load, memory
consumption, service load and file system load
in SMM and RMM.
Chapter 23, Q3 Module Measurement This chapter describes the Q3 module
measurement counters.
Chapter 24, Q3 Cell and BTS This chapter describes the Q3 Cell and Q3 BTS
measurement Measurement Counters. These counters
provide statistics for received signal level,
received signal quality and call distance.
Chapter 25, Adjacent Cell Handover This chapter describes the measurement
Measurement counters for handover between the specified
cells and their adjacent cells.

xii Confidential and Proprietary Information of ZTE CORPORATION


About this Operation Guide

Section Summary
Chapter 26, Phase-3 NMS Measurement This chapter describes counters for phase three
for Cell NMS – cell basic measurement and measuring
points
Chapter 27, TCH/H Measurement This chapter describes TCH/H Measurement
Counters.
Chapter 28, HR Statistics This chapter provides statistics for the HR
related services and resources.
Chapter 29, Statistic Measurement due to This chapter describes statistic measurement
dual frequency on the same cell counter related to dual frequency on the same-
cell and measurement points

Typographical Conventions
ZTE documents employ the following typographical conventions.

TABLE 2 TYPOGRAPHICAL CONVENTIONS

Typeface Meaning
Italics References to other guides and documents.
“Quotes” Links on screens.
Bold Menus, menu options, input fields, radio button names, check
boxes, drop-down lists, dialog box names, window names

Bold, with first Keys on the keyboard and buttons on screens


letter capitalized
Constant width Text that you type, program code, files and directory names,
and function names
[] Optional parameters
{} Mandatory parameters
| Select one of the parameters that are delimited by it

Note: Provides additional information about a certain topic.

Checkpoint: Indicates that a particular step needs to be checked


before proceeding further.

Tip: Indicates a suggestion or hint to make things easier or


more productive for the reader.

Confidential and Proprietary Information of ZTE CORPORATION xiii


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Mouse Operation Conventions


TABLE 3 MOUSE OPERATION CONVENTIONS

Typeface Meaning
Click Represents clicking the primary mouse button (usually the left
mouse button) once.
Double-click Represents quickly clicking the primary mouse button (usually
the left mouse button) twice.
Right-click Represents clicking the secondary mouse button (usually the
right mouse button) once.
Drag Represents pressing and holding a mouse button and moving
the mouse.

xiv Confidential and Proprietary Information of ZTE CORPORATION


About this Operation Guide

Safety Signs
TABLE 4 SAFETY SIGNS

Safety Signs Meaning


Danger: Indicates an imminently hazardous situation, which if
not avoided, will result in death or serious injury. This signal
word should be limited to only extreme situations.

Warning: Indicates a potentially hazardous situation, which if


not avoided, could result in death or serious injury.
Caution: Indicates a potentially hazardous situation, which if not
avoided, could result in minor or moderate injury. It may also
be used to alert against unsafe practices.
Note: Indicates a potentially hazardous situation, which if not
avoided, could result in injuries, equipment damage or
interruption of services.

Erosion: Beware of erosion.

Electric shock: There is a risk of electric shock.

Electrostatic: The device may be sensitive to static electricity.

Microwave: Beware of strong electromagnetic field.

Laser: Beware of strong laser beam.

No flammables: No flammables can be stored.

No touching: Do not touch.

No smoking: Smoking is forbidden.

Confidential and Proprietary Information of ZTE CORPORATION xv


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

How to Get in Touch


The following sections provide information on how to obtain support for
the documentation and the software.

Customer Support
If you have problems, questions, comments, or suggestions regarding
your product, contact us by e-mail at support@zte.com.cn. You can also
call our customer support center at (86) 755 26771900 and (86) 800-
9830-9830.

Documentation Support
ZTE welcomes your comments and suggestions on the quality and
usefulness of this document. For further questions, comments, or
suggestions on the documentation, you can contact us by e-mail at
doc@zte.com.cn; or you can fax your comments and suggestions to (86)
755 26772236. You can also explore our website at
http://support.zte.com.cn, which contains various interesting subjects like
documentation, knowledge base, forum and service request.

xvi Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1

Key Performance Indicators

This chapter covers the following topics;

Network Performance Measurement

Network Performance
Measurement
In GSM, performance of the network can be analyzed through KPIs. KPIs
are the specific counters, which represent statistics of overall performance
of the network. Network performance judgment such as about resource
status, service status or channel quality is possible through these statistics.
Statistics comes from the basic measurement of the Control System.
Degradation in the performance of the specific cells can be identified in
OMCR by analyzing the KPIs. In this way specific problem can be resolved
accordingly.

Table 4 lists the entire Key Performance Measurement Counters.

KPI Counters
TABLE 5 KEY PERFORMANCE INDICATORS

Counter No. Counter Definition


C11601 Total number of available SDCCHs
C11602 Total number of unavailable SDCCHs
C11603 Total number of attempts for SDCCH.
C11604 Total number of SDCCH overflows
C11605 Total number of SDCCH call drops
C11606 Total SDCCH busy time
C11607 Total number of available TCHs
C11608 Total number of unavailable TCHs

Confidential and Proprietary Information of ZTE CORPORATION 1


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Counter No. Counter Definition


C11609 Total number of call attempts of TCHs (excluding handover)
C11610 Total number of overflows of TCHs (excluding handover)
C11611 Total number of call attempts of the TCHs (including handover)
C11612 Total number of overflows of the TCHs (including handover)
C11613 Total number of seizures of TCHs (excluding handover)
C11614 Total number of seizures of TCHs (including handover)
C11615 Total number of TCH call drops
C11616 Total busy time of TCHs
C11617 Total number of handover requests (number of executing handin)
C11618 Total number of successful handovers (number of successful handin)
C11619 Total dual band handover call attempts
C11620 Number of successful dual band handovers
C11621 Number of sending paging messages
C11622 Number of call drops due to wireless link failure
C11623 Number of call drops due to LAPD link failure
C11624 Number of call drops due to handover failure
C11625 Number of random access call attempts
C11626 Number of successful random access
C11627 Maximum number of busy SDCCHs
C11628 Mean number of busy SDCCHs
C11629 Total time of SDCCH congestion
C11630 Maximum number of busy TCH/Fs
C11631 Mean number of busy TCH/Fs
C11632 Total time of TCH/F congestion
C11633 Total number of healthy TRXs
C11634 Number of successful access of emergency calls
C11635 Number of successful access of call re-establishment
C11636 Number of MOC access success
C11637 Number of MTC access success
C11638 Number of LOC access success
C11639 Number of other successful access requests
C11640 Number of SDCCH allocation successes (excluding handover)
C11641 Number of SDCCH allocation failures (excluding handover)
C11642 Number of SDCCH allocation successes (including handover)
C11643 Number of SDCCH allocation failures (including handover)
C11644 Number of successful SDCCH assignments
C11645 Number of failed SDCCH assignments

2 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - Key Performance Indicators

Counter No. Counter Definition


C11646 Number of successful SDCCH handovers
C11647 Number of failed SDCCH handover with return
C11648 Number of failed SDCCH handover without return
Number of DTAP messages used as SDCCH uplink point-to-point short
C11649
messages (SMs)
Number of DTAP messages used as SDCCH downlink point-to-point
C11650
short messages (SMs)
Number of DTAP messages used as FACCH/F uplink point-to-point
C11651
short messages (SMs)
Number of DTAP messages used as FACCH/F downlink point-to-point
C11652
short messages (SMs)
C11653 Number of TCH/F allocation successes (excluding handover)
C11654 Number of TCH/F allocation failures (excluding handover)
C11655 Number of TCH/F allocation successes (including handover)
C11656 Number of TCH/F allocation failures (including handover)
C11657 Number of TCH/F assignment successes
C11658 Number of TCH/F assignment failures
C11659 Number of TCH/F handover successes
C11660 Number of failed TCH/F handover with return
C11661 Number of failed TCH/F handover without return
C11662 Number of assignment queuing attempts
C11663 Number of assignment execution due to queuing
C11664 Total time of successful assignment queuing
C11665 Number of assignment queuing successes
C11666 Number of assignment directed retry attempts
C11667 Number of assignment execution because of directed retry
C11668 Handout executions
C11669 Successful handout times
C11670 Mean number of idle TCHs with interference band 1
C11671 Mean number of idle TCHs with interference band 2
C11672 Mean number of idle TCHs with interference band 3
C11673 Mean number of idle TCHs with interference band 4
C11674 Mean number of idle TCHs with interference band 5
C11675 Intra-cell successful handover times
C11676 Intra-cell failed handover times
Number of Intra-BSC intra-cell hand in attempts (the actual value is
C11677
the number of hand in execution)
C11678 Number of successful Intra-BSC intra-cell hand ins
C11679 Number of Intra-BSC intra-cell handout attempts (the actual value is

Confidential and Proprietary Information of ZTE CORPORATION 3


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Counter No. Counter Definition


the number of handout execution)
C11680 Number of successful Intra-BSC intra-cell handouts
C11681 Total number of TRXs
C11682 Number of access attempts of emergency calls
C11683 Number of access attempts of call re-establishment
C11684 Number of MOC access attempts
C11685 Number of MTC access attempts
C11686 Number of LOC access attempts
C11687 Number of other access request attempts
C11688 Dual band handout executions
C11689 Number of successful dual band handouts
Number of access due to location update (statistics establishment
C11690
indication)
Number of access due to originating calls (statistics establishment
C11691
indication)
Number of access due to paging response (statistics establishment
C11692
indication)
Number of access due to call re-establishment (statistics establishment
C11693
indication)
Number of access due to IMSI detachment (statistics establishment
C11694
indication)
C11695 Number of access due to others (statistics establishment indication)
Total number of call attempts of the TCHs (excluding handover)
C11696
(signaling)
Total number of overflows of the TCHs (excluding handover)
C11697
(signaling)
Total number of call attempts of the TCHs (including handover)
C11698
(signaling)
Total number of overflows of the TCHs (including handover)
C11699
(signaling)
C116100 Number of TCH/F allocation success (excluding handover) (signaling)
C116101 Number of TCH/F allocation failures (excluding handover) (signaling)
C116102 Number of TCH/F allocation success (including handover) (signaling)
C116103 Number of TCH/F allocation failures (including handover) (signaling)
C116104 Handover attempt due to uplink receiving strength (on TCH/F)
C116105 Handover attempt due to downlink receiving strength (on TCH/F)
C116106 Handover attempt due to uplink interference (on TCH/F)
C116107 Handover attempt due to downlink interference (on TCH/F)
C116108 Handover attempt due to C/I RATIO concentric cells (on TCH/F)
C116109 Handover attempt due to PBGT (on TCH/F)
C116110 Handover attempt due to too large TA (on TCH/F)

4 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - Key Performance Indicators

Counter No. Counter Definition


C116111 Handover attempt due to uplink quality (on TCH/F)
C116112 Handover attempt due to downlink quality (on TCH/F)
C116113 Handover attempt due to other factors (on TCH/F)
C116114 Number of samples with uplink RQ = 0
C116115 Number of samples with uplink RQ = 1
C116116 Number of samples with uplink RQ = 2
C116117 Number of samples with uplink RQ = 3
C116118 Number of samples with uplink RQ = 4
C116119 Number of samples with uplink RQ = 5
C116120 Number of samples with uplink RQ = 6
C116121 Number of samples with uplink RQ = 7
C116122 Number of samples with downlink RQ = 0
C116123 Number of samples with downlink RQ = 1
C116124 Number of samples with downlink RQ = 2
C116125 Number of samples with downlink RQ = 3
C116126 Number of samples with downlink RQ = 4
C116127 Number of samples with downlink RQ = 5
C116128 Number of samples with downlink RQ = 6
C116129 Number of samples with downlink RQ = 7
C116130 Number of call drops due to inter-BSC handover failure
C116131 Total half rate channel busy time

KPI Counters Explanation


C11601
Definition

Number of available SDCCHs


Description

C11601 represents the number of SDCCHs in each cell that can be


assigned.
Refer to section Resource Availability Counters for C11501 explanation.
Calculation formula

C11601=C11501

Confidential and Proprietary Information of ZTE CORPORATION 5


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C11602
Definition

Number of unavailable SDCCHs


Description

C11602 represents the number of SDCCHs in each cell that cannot be


assigned.
Refer to section Resource Availability Counters for C11502 explanation.
Calculation formula

C11602 = C11502

C11603
Definition

Total number of attempts for SDCCH


Description

C11603 represents the total number of requests for SDCCHs. Request


for SDCCH includes all the causes such as normal call origination,
location update, call re-establishment, IMSI request, IMSI separation
and short messages.
Refer to section SDCCH Counters Explanation for counters (C10101,
C10104) explanation.
Measurement Point
Reception of the ‘Channel Request’ message
Calculation formula

C11603 = C10101 + C10104

C11604
Definition

Total number of SDCCH overflows


Description

C11604 represents all the unsuccessful requests for SDCCH due to the
limited Radio Resource (RR). Overflow means no channel is available to
fulfill the SDCCH request.
Refer to section SDCCH Counters Explanationfor counter (C10103,
C10106) explanation.
Calculation formula

C11604= C10103+ C10106

6 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - Key Performance Indicators

C11605
Definition

Total number of SDCCH call drops


Description

C11605 represents the total number of call drops after SDCCHs


assignment and before seizure of TCHs during calls.
Refer to section Call Drop Counters Explanation for counter (C10643)
explanation.
Calculation formula

C11605= C10643

C11606
Definition

Total SDCCH busy time


Description

It represents the total time of SDCCH seizure in each cell.


Refer to section Resource Availability Counters Explanation for counter
(C11505) explanation.
Calculation formula

C11606=C11505

C11607
Definition

Total number of available TCHs


Description

C11607 represents the number of TCHs that can be assigned in cells.


TCHs include the number of TCH/Fs and that of TCH/Hs.
Refer to section Resource Availability Counters Explanation for
counters (C11507, C11513) explanation.
Calculation formula

C11607=C11507+C11513

C11608
Definition

Total number of unavailable TCHs

Confidential and Proprietary Information of ZTE CORPORATION 7


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Description

C11608 represents the number of TCHs that can not be assigned in


cells. TCHs include the number of TCH/Fs and that of TCH/Hs.
Refer to section Resource Availability Counters Explanation for
counters (C11508, C11514) explanation.
Calculation formula

C11608=C11508+C11514

C11609
Definition

Total number of call attempts for TCH (excluding handover)


Description

C11609 represents the total number of calls attempts for TCHs (seizure
attempts) after all SDCCHs in cells are seized.
Refer to section TCHF Counters Explanation for C10301, C10320,
C10351 and TCHH Counters Explanation for C10401, C10420 and
C10451 explanation.
Calculation formula

C11609=C10301+C10320+C10351+C10401+C10420+C10451

C11610
Definition

Total number of unsuccessful assignments due to TCH overflow


(excluding handover)
Description

It represents the number of overflows in calls to TCHs after all SDCCHs


in cells are seized. Overflows mean TCH setup failures after the calling
or called occupies SDCCHs, including the case where TCH is assigned
as SDCCH in abnormal early allocation but excluding different
handover cases. TCHs comprise TCH/Fs and TCH/Hs.
Calculation formula

C11610=C10303+C10322+C10353+C10403+C10422+C10453

C11611
Definition

Total number of call attempts for TCH (including handover)


Description

8 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - Key Performance Indicators

It represents the number of call attempts to TCHs after all SDCCHs in


cells are seized. Call attempts comprise the calling attempts and called
attempts, including the case TCH is assigned as SDCCH in abnormal
early allocation and also including different handover cases and direct
retries. TCHs comprise TCH/Fs and TCH/Hs.
Refer to sections TCHF Counters Explanation and TCHH Counters
Explanation.
Calculation formula

C11611=C11609+C10304+C10323+C10354+C10404+C10423+C1045
4

C11612
Definition

Total number of unsuccessful assignments due to TCH overflow


(including handover)
Description

It represents the number of overflows in calls to TCHs after all SDCCHs


in cells are seized. Overflows comprise the TCH setup failures after the
calling or called occupies SDCCH. It also includes the case where TCH
is assigned as SDCCH in abnormal early allocation and also including
different handover and direct retries. TCHs comprise TCH/Fs and
TCH/Hs.
Refer to sections TCHF Counters Explanation and TCHH Counters
Explanation.
Calculation formula

C11612=C11610+C10306+C10325+C10356+C10406+C10425
+ C10456

C11613
Definition

Total number of TCH seizures (excluding handover)


Description

It represents the number of successful seizures of TCHs (excluding


handover), including voice and data seizures. TCHs comprise TCH/Fs
and TCH/Hs.
Refer to sections TCHF Counters Explanation and TCHH Counters
Explanation.
Calculation formula

C11613=C10302+C10321+C10352+C10402+C10421+C10452.

Confidential and Proprietary Information of ZTE CORPORATION 9


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C11614
Definition

Total number of TCH seizures (including handover)


Description

It represents the number of successful seizures of TCHs (including


handover), including voice and data seizures. TCHs comprise TCH/Fs
and TCH/Hs.
Refer to sections TCHF Counters Explanation and TCHH Counters
Explanation.
Calculation formula

C11614=C11613+C10305+ C10324+ C10355+ C10405+ C10424+


C10455

C11615
Definition

Total number of TCH call drops


Description

It represents call losses due to wireless factors after TCHs are


successfully assigned to users. Call losses comprise the call drops
during handover and after handover. TCHs comprise TCH/Fs and
TCH/Hs.
Refer to sections TCHF Counters Explanation and TCHH Counters
Explanation.
Calculation formula

C11615=C10644+C10645

C11616
Definition

Total busy time of TCH

Description

It represents the total traffic of all TCHs in this system. TCHs comprise
TCH/Fs and TCH/Hs.
Refer to the Section Resource Availability Counters
Calculation formula

C11616=C11511+C11517

10 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - Key Performance Indicators

C11617
Definition

Total number of handover requests


Description

It represents the total number of requests for handover between cells


in the same BSC and between those in different BSCs. Requests for
handing into cells is measured.
Refer to the Section Handover Counters Explanation

Calculation formula

C11617=C10912+C10915+C10917+C10919+C10982

C11618
Definition

Total number of successful handovers


Description

It represents the total number of successful handovers between cells in


the same BSC and between those in different BSCs. Number of
successful handing into cells is measured.
Refer to the Section Handover Counters Explanation
Calculation formula

C11618=C10913+C10920+C10982

C11619
Definition

Total dual-band handover attempts


Description

It represents the number of attempts of handover between the GSM


900 system and the GSM 1800 system, including handover both in the
same layer and between different layers.
Refer to the Section Handover Counters Explanation
Calculation formula

C11619=C10934+C10939+C10952+C10957+C10962+C10967+
C15972+ C15977

Confidential and Proprietary Information of ZTE CORPORATION 11


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C11620
Definition

Total number of successful dual-band handovers in busy time


Description

It represents the number of successful handovers between the


GSM900 system and the GSM1800 system, including handovers both in
the same layer and between different layers.
Refer to the Section Handover Counters Explanation
Calculation formula

C11620= C10935+ C10940+ C10953+ C10958+ C10963+ C10968


+ C15973+ C15978

C11621
Definition

Total number of paging messages


Description

It represents the number of cells sending paging messages.


Refer to the Section Paging Messages Measurement Counters
Calculation formula

C11621= C11301

C11622
Definition

Number of call drops due to wireless link failure


Description

It represents the number of call drops due to wireless link failure,


including voice and data. Call drops comprise those on TCH/Fs and
those on TCH/Hs.
Refer to section Call Drop Counters Explanation for counters (C10608,
C10614, C10620, C10626, C10632 and C10638) explanation.
Calculation formula

C11622=C10608+C10614+C10620+C10626+C10632+C10638

C11623
Definition

Number of call drops due to LAPD link failure

12 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - Key Performance Indicators

Description

It represents the number of call drops due to LAPD link breakage,


including voice and data. Call drops comprise those on TCH/Fs and
those on TCH/Hs.
Refer Call Drop Counters Explanation for counters (C10609, C10615,
C10621, C10627, C10633 and C10639) explanation.
Calculation formula

C11623=C10609+C10615+C10621+C10627+C10633+C10639

C11624
Definition

Number of call drops due to handover failure


Description

It represents the number of call drops due to handover failure,


including voice and data. Call drops comprise those on SDCCHs,
TCH/Fs and TCH/Hs.
Refer to section Call Drop Counters Explanation for counters (C10646,
C10647, C10648, C10649, C10650, C10651 and C10652) explanation.
Calculation formula

C11624=C10646+C10647+C10648+C10649+C10650+C10651
+C10652

C11625
Definition

Number of requests on RACH


Description

Refer to the description of the counter in section SDCCH Counters


Explanation.
Calculation formula

C11625 = C10101

C11626
Definition

Number of successful requests on RACH


Description

Refer to the description of the counter (C10102) in Section SDCCH


Counters Explanation.

Confidential and Proprietary Information of ZTE CORPORATION 13


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Calculation formula

C11626 = C10102

C11627
Definition

Maximum number of busy SDCCHs


Description

Refer to the description of the counter (C11503) in Section Resource


Availability Counters Explanation.
Calculation formula

C11627 = C11503

C11628
Definition

Mean number of busy SDCCHs


Description

Refer to the description of the counter (C11504) in Section Resource


Availability Counters Explanation.
Calculation formula

C11628 = C11504

C11629
Definition

Total SDCCH congestion time


Description

Refer to the description of the counter (C11506) in Section Resource


Availability Counters Explanation.
Calculation formula

C11629 = C11506

C11630
Definition

Maximum number of busy TCH/Fs


Description

Refer to the description of the counter (C11515) in Section Resource


Availability Counters Explanation.

14 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - Key Performance Indicators

Calculation formula

C11630 = C11515

C11631
Definition

Mean number of busy TCH/Fs


Description

Refer to the description of the counter (C11516) in Section Resource


Availability Counters Explanation.
Calculation formula

C11631 = C11516

C11632
Definition

Total TCH/F congestion time


Description

Refer to the description of the counter (C11518) in Section Resource


Availability Counters Explanation.
Calculation formula

C11632 = C11518

C11633
Definition

Total number of healthy TRXs


Description

Refer to the description of the counter (C11520) in Section Resource


Availability Counters Explanation.
Calculation formula

C11633 = C11520

C11634
Definition

Number of successful accesses for emergency calls


Description

Refer to the description of the counter C10013 in Section Random


Access Counters Explanation.

Confidential and Proprietary Information of ZTE CORPORATION 15


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Calculation formula

C11634 = C10013

C11635
Definition

Number of successful accesses for call re-establishment


Description

Refer to the description of the counter C10010 in Section Random


Access Counters Explanation.
Calculation formula

C11635 = C10010

C11636
Definition

Number of successful MOC accesses


Description

Refer to the description of the counter C10014 in Section Random


Access Counters Explanation.
Calculation formula

C11636 = C10004

C11637
Definition

Number of successful MTC accesses


Description

Refer to the description of the counter C10007 in Section Random


Access Counters Explanation.
Calculation formula

C11637 = C10007

C11638
Definition
Number of LOC access success
Description

Refer to the description of the counter C10016 in Section Random


Access Counters Explanation.

16 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - Key Performance Indicators

.
Calculation formula

C11638 = C10016

C11639
Definition

Number of other successful access requests


Description

Refer to the description of the counter C10019 in Section Random


Access Counters Explanation.
Calculation formula

C11639 = C10019

C11640
Definition

Number of successful SDCCH allocations (excluding handover)


Description

Refer to the description of the counter C10108 in Section SDCCH


Counters Explanation.
Calculation formula
C11640 = C10108

C11641
Definition

Number of SDCCH allocation failures (excluding handover)


Description

Refer to the description of the counter (C10109) in Section SDCCH


Counters Explanation.
Calculation formula

C11641 = C10109

C11642
Definition

Number of SDCCH allocation successes (including handover)


Description

Confidential and Proprietary Information of ZTE CORPORATION 17


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Refer to the description of the counter (C10111) in Section SDCCH


Counters Explanation.
Calculation formula

C11642 = C11640 + C10111

C11643
Definition

Number of SDCCH allocation failures (including handover)


Description

Refer to the description of the counter (C10112) in Section SDCCH


Counters Explanation.
Calculation formula

C11643 = C11641 + C10112

C11644
Definition

Number of successful SDCCH assignments


Description

Refer to the description of the counter (C10114) in Section SDCCH


Counters Explanation.
Calculation formula

C11644 = C10114

C11645
Definition

Number of unsuccessful SDCCH assignments


Description

Refer to the description of the counter (C10115) in Section SDCCH


Counters Explanation.
Calculation formula

C11645 = C10115

C11646
Definition

Number of successful SDCCH handovers


Description

18 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - Key Performance Indicators

Refer to the description of the counter (C10117) in Section SDCCH


Counters Explanation.
Calculation formula

C11646 = C10117

C11647
Definition

Number of unsuccessful SDCCH handover with return


Description

Refer to the description of the counter (C10117) in Section SDCCH


Counters Explanation.
Calculation formula

C11647 = C10118

C11648
Definition

Number of failed SDCCH handover without return


Description

Refer to the description of the counter (C10119) in Section SDCCH


Counters Explanation.
Calculation formula

C11648 = C10119

C11649
Definition

Number of DTAP messages used as SDCCH uplink point-to-point short


messages (SMs)
Description

Refer to the description of the counter C10216 in Section SAPI 3


Counters Explanation
Calculation formula

C11649 = C10216

C11650
Definition

Number of DTAP messages used as SDCCH downlink point-to-point


short messages (SMs)

Confidential and Proprietary Information of ZTE CORPORATION 19


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Definition

Refer to the description of the counter (C10217) in Section SAPI 3


Counters Explanation
Calculation formula

C11650 = C10217

C11651
Definition

Number of DTAP messages used as FACCH/F uplink point-to-point


short messages (SMs)
Description

Refer to the description of the counter C10218 in Section SAPI 3


Counters Explanation
Calculation formula

C11651 = C10218

C11652
Definition

Number of DTAP messages used as FACCH/F downlink point-to-point


short messages (SMs)
Description

Refer to the description of the counter (C10219) in Section SAPI 3


Counters Explanation
Calculation formula

C11652 = C10219

C11653
Definition

Number of TCH/F allocation successes (excluding handover)


Description

It represents the number of receiving activation response messages


after channels are activated in assigning TCH/Fs for assignment
(signaling, voice and data).
Refer to the description of the counters C10308, C10327, C10333,
C10339 and C10358 in section TCHF Counters Explanation.
Calculation formula

C11653 = C10308 + C10327 + C10333 + C10339 +C10358

20 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - Key Performance Indicators

C11654
Definition

Number of TCH/F allocation failures (excluding handover)


Description

It represents the number negative replies in response TCH/F activation


request for assignment (signaling, voice and data).
Refer to the description of the counters C10309, C10328, C10334,
C10340 and C10359 in section TCHF Counters Explanation.
Calculation formula

C11654 = C10309 + C10328 + C10334 + C10340 + C10359

C11655
Definition

Number of TCH/F allocation successes (including handover)


Description

It represents the number of receiving activation response messages


after channels are activated in assigning and hand over to TCH/Fs
(voice and data).
Refer to the description of the counters C10311, C10330, C10336,
C10342 and C10361 in Section TCHF Counters Explanation.
Calculation formula

C11655 = C11653 + C10311 + C10330 + C10336 + C10342 +


C10361

C11656
Definition

Number of TCH/F allocation failures (including handover)


Description

It represents the number negative replies in response of TCH/F


activation request for assignment and handover (voice and data).
Refer to the description of the counters C10312, C10331, C10337,
C10343 and C10362 in section TCHF Counters Explanation.
Calculation formula

C11656 = C11654 + C10312 + C10331 + C10337 + C10343 +


C10362

Confidential and Proprietary Information of ZTE CORPORATION 21


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C11657
Definition

Number of TCH/F assignment successes


Description

It represents the number of receiving Establish Indication or


Assignment Complete messages after TCH/F assignment command
(signaling, voice and data).
Refer to the description of the counters C10314, C10345 and C10364
in section TCHF Counters Explanation.
Calculation formula

C11657 = C10314 + C10345 +C10364

C11658
Definition

Number of TCH/F assignment failures


Description

It represents the number negative replies in response of TCH/F


Assignment Command (signaling, voice and data).
Refer to the description of the counter C10315, C10346 and C10365 in
section TCHF Counters Explanation.
Calculation formula

C11658 = C10315 + C10346 +C10365

C11659
Definition

Number of TCH/F handover successes


Description

It represents the number of successful TCH/F handovers after receiving


the handover complete or assignment complete messages (signaling,
voice and data).
Refer to the description of the counters C10317, C10348 and C10367
in section TCHF Counters Explanation.
Calculation formula

C11659 = C10317 + C10348 +C10367

22 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - Key Performance Indicators

C11660
Definition

Number of failed TCH/F handover with return


Description

It represents the number of receiving the handover failure or


assignment failure messages during TCH/Fs handover (signaling, voice
and data).
Refer to the description of the counters C10318, C10349 and C10368
in section TCHF Counters Explanation.
Calculation formula

C11660 = C10318 + C10349 +C10368

C11661
Definition

Number of failed TCH/F handover without return


Description

It represents the number of not receiving the handover failure or


assignment failure messages during TCH/Fs handover (signaling, voice
and data).
Refer to the description of the counters C10319, C10350 and C10369
in section TCHF Counters Explanation.
Calculation formula
C11661 = C10319 + C10350 +C10369

C11662
Definition

Number of assignment queuing attempts


Description

It represents the number of queuing for resources after voice and data
services fail to apply for resources.
Refer to the description of the counter C10504 and C10513 in Section
RMM Assignment Counters Explanation
Calculation formula

Confidential and Proprietary Information of ZTE CORPORATION 23


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C11662 = C10504 + C10513

C11663
Definition

Number of successful assignments after queuing


Description

It represents the number of successful assignments after queuing for


voice and data channel.
Refer to the description of the counters C10505 and C10514 in Section
RMM Assignment Counters Explanation
Calculation formula

C11663 = C10505 + C10514

C11664
Definition

Total time of successful assignment queuing


Description

It represents the total time for voice and data services queue to obtain
channels.
Refer to the description of the counter C10506 and C10515 in Section
RMM Assignment Counters Explanation.
Calculation formula

C11664 = C10506 + C10515

C11665
Definition

Number of assignment queuing successes


Description

It represents the number of successful channel assignments after


queuing (voice and data channels).
Calculation formula

C11665 = C10507 + C10516

C11666
Definition

Number of assignment attempts for direct retry


Description

24 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - Key Performance Indicators

It represents the number of voice and data assignment attempts for


directed retry.
Refer to the description of the counter C10508 and C10517 in Section
RMM Assignment Counters Explanation.
Calculation formula

C11666 = C10508 + C10517

C11667
Definition

Number of assignment execution because of directed retry


Description

It represents the number of voice and data assignment executions for


directed retry.
Refer to the description of the counters C10509 and C10518 in RMM
Assignment Counters Explanation.
Calculation formula

C11667 = C10509 + C10518

C11668
Definition

Handover out executions


Description

It represents the total number of handover out executions for intra-cell


handover, Intra-BSC inter-cell handover and Intra-MSC inter-cell
handover.
Refer to the description of the counter C10902, C10909 and C10982 in
Section Handover Counters Explanation.
Calculation formula

C11668 = C10902 + C10909 +C10982

C11669
Definition

Number of successful handover outs


Description

It represents the total number of successful handover outs for intra-


cell handover, Intra-BSC inter-cell handover and Intra-MSC inter-cell
handover.

Confidential and Proprietary Information of ZTE CORPORATION 25


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Refer to the description of the counter C10903, C10910 and C10982 in


Section Handover Counters Explanation.

Calculation formula

C11669 = C10903 + C10910 +C10982

C11670
Definition

Mean number of idle TCHs with interference band 1


Description

It represents the total mean number ofidle TCH/Fs and TCH/Hs with
interference band 1.
Refer to the description of the counters C10719 and C10725 in Section
Channels Counters Explanation.
Calculation formula

C11670 = C10719 + C10725

C11671
Definition

Mean number of idle TCHs with interference band two


Description

It represents the total mean number of idle TCH/Fs and TCH/Hs with
interference band 2.
Refer to the description of the counters C10720 and C10726 in Section
Channels Counters Explanation.
Calculation formula

C11671 = C10720 + C10726

C11672
Definition

Mean number of idle TCHs with interference band three


Description

It represents the total mean number of idle TCH/Fs and TCH/Hs with
interference band 3.
Refer to the description of the counters C10721 and C10727 in Section
Channels Counters Explanation.
Calculation formula

C11672 = C10721 + C10727

26 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - Key Performance Indicators

C11673
Definition

Mean number of idle TCHs with interference band four


Description

It represents the total Mean number of idle TCH/Fs and TCH/Hs with
interference band 4.
Refer to the description of the counter C10722 and C10728 in Section
Channels Counters Explanation.
Calculation formula

C11673 = C10722 + C10728

C11674
Definition

Mean number of idle TCHs with interference band five


Description

It represents the total mean number of idle TCH/Fs and TCH/Hs with
interference band five.
Refer to the description of the counter C10723 and C10729 in Section
Channels Counters Explanation.
Calculation formula

C11674 = C10723 + C10729

C11675
Definition

Number of successful Intra-cell handovers.


Description

Refer to the description of the counter C10982 in Section Handover


Counters Explanation
Calculation formula

C11675 = C10982

C11676
Definition

Number of Intra-cell handover failures.


Description

It represents the number of intra-cell handover failures.

Confidential and Proprietary Information of ZTE CORPORATION 27


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Refer to the description of the counter C10981 and C10982 in Section


Handover Counters Explanation
Calculation formula

C11676 = C10981 - C10982

C11677
Definition

Number of intra-BSC handover in attempts


Description

Refer to the description of the counter C10912 in Section Handover


Counters Explanation
Calculation formula

C11677 = C10912

C11678
Definition

Number of successful Intra-BSC intra-cell handover in


Description

Refer to the description of the counter C10913 in Section Handover


Counters Explanation
Calculation formula

C11678 = C10913

C11679
Definition

Number of Intra-BSC intra-cell handout attempts


Description

Refer to the description of the counter C10902 in Section Handover


Counters Explanation
Calculation formula

C11679 = C10902

C11680
Definition

Number of successful Intra-BSC intra-cell handouts


Description

28 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - Key Performance Indicators

Refer to the description of the counter C10903 in Section Handover


Counters Explanation.
Calculation formula

C11680 = C10903

C11681
Definition

Total number of TRXs


Description

Refer to the description of the counter C11519.


Calculation formula

C11681 = C11519

C11682
Definition

Number of access attempts of emergency calls


Description

Refer to the description of the counter C10011 in Section Random


Access Counters Explanation.
Calculation formula

C11682 = C10011

C11683
Definition

Number of access attempts of call re-establishment


Description

Refer to the description of the counter C10008 in Section Random


Access Counters Explanation.
Calculation formula

C11683 = C10008

C11684
Definition

Number of MOC access attempts


Description

Confidential and Proprietary Information of ZTE CORPORATION 29


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Refer to the description of the counter C10002 in Section Random


Access Counters Explanation.
Calculation formula

C11684 = C10002

C11685
Definition

Number of MTC access attempts


Description

Refer to the description of the counter C10005 in Section Random


Access Counters Explanation.
Calculation formula

C11685 = C10005

C11686
Definition

Number of LOC access attempts


Description

Refer to the description of the counter C10014 in Section Random


Access Counters Explanation.
Calculation formula

C11686 = C10014

C11687
Definition

Number of other access request attempts


Description

Refer to the description of the counter C10017 in Section Random


Access Counters Explanation.
Calculation formula

C11687 = C10017

C11688
Definition

Number of dual band handover out attempts


Description

30 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - Key Performance Indicators

It represents the number of handover from the GSM 900 to the GSM
1800 and handover from the GSM 1800 to GSM 900.
Refer to the description of the counter C10991 and C10992 in Section
Handover Counters Explanation.
Calculation formula

C11688 = C10991 + C10992

C11689
Definition

Number of successful dual band handover outs.


Description

It represents the number of successful handover from the GSM 900 to


the GSM 1800 and successful handover from the GSM 1800 to the GSM
900.
Refer to the description of the counters C10937, C10942, C10955,
C10960, C10965, C10970, C10975 and C10980 in Section Handover
Counters Explanation.
Calculation formula

C11689 = C10937 + C10942 + C10955 + C10960 + C10965 +


C10970 + C10975 + C10980

C11690
Definition

Number of accesses due to location updates (statistics establishment


indication)
Description

Refer to the description of the counter C10020 in Section Random


Access Counters Explanation.
Calculation formula

C11690 = C10020

C11691
Definition

Number of accesses due to call origination (statistics establishment


indication)
Description

Refer to the description of the counter C10021 in Section Random


Access Counters Explanation.

Confidential and Proprietary Information of ZTE CORPORATION 31


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Calculation formula

C11691 = C10021

C11692
Definition

Number of accesses due to paging response (statistics establishment


indication)
Description

Refer to the description of the counter C10022 in Section Random


Access Counters Explanation.
Calculation formula

C11692 = C10022

C11693
Definition

Number of accesses due to call re-establishment (statistics


establishment indication)
Description

Refer to the description of the counter C10023 in Section Random


Access Counters Explanation.
Calculation formula

C11693 = C10023

C11694
Definition

Number of access due to IMSI detachment (statistics establishment


indication)
Description

Refer to the description of the counter C10024 in Section Random


Access Counters Explanation.
Calculation formula

C11694 = C10024

C11695
Definition

Number of access due to others (statistics establishment indication)


Description

32 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - Key Performance Indicators

Refer to the description of the counter C10025 in Section Random


Access Counters Explanation.
Calculation formula

C11695 = C10025

C11696
Definition

Number of call attempts on TCH (signaling) (excluding handover)


Description

It represents the total number of call attempts on TCH/Fs and TCH/Hs


for signaling assignment.
Refer to the description of the counter C10301 and C10401 in Section
TCHF Counters Explanation
Calculation formula

C11696 = C10301 + C10401

C11697
Definition

Total number of overflows of the TCHs (excluding handover) (signaling)


Description

It represents the total number of failures in call attempt for TCH/Fs


and TCH/Hs for signaling assignment.
Refer to the sections TCHH Counters Explanation and Channels
Counters Explanation.
Calculation formula

C11697 = C10303 + C10403

C11698
Definition

Total number of TCHs call attempts (including handover) (signaling)


Description

It represents the total number of call attempts on TCH/Fs and TCH/Hs


for signaling assignment and handover.
Calculation formula

C11698 = C11696 + C10304 +C10404

Confidential and Proprietary Information of ZTE CORPORATION 33


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C11699
Definition

Total number of overflows of the TCHs (including handover) (signaling)


Description

It represents the total number of failures in call attempt applying for


channels on TCH/Fs and TCH/Hs for signaling assignment and
handover.
Calculation formula

C11699 = C11697 + C10306 +C10406

C116100
Definition

Number of successful TCH/F allocation (excluding handover) (signaling)


Description

Refer to the description of the counter C10308 in Section TCHF


Counters Explanation.
Calculation formula

C116100 = C10308

C116101
Definition

Number of TCH/F allocation failure (excluding handover) (signaling)


Description

Refer to the description of the counter C10309 in Section TCHF


Counters Explanation.
Calculation formula

C116101 = C10309

C116102
Definition

Number of TCH/F allocation success (including handover) (signaling)


Description

It represents the number of TCH/F allocation success for assignment


and handover.
Refer to counter C116100 and explanation of the counter C10311 in
Section TCHF Counters Explanation.

34 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - Key Performance Indicators

Calculation formula

C116102 = C116100 + C10311

C116103
Definition

Number of TCH/F allocation failure (including handover) (signaling)


Description

It represents the number of TCH/F allocation failures for assignment


and handover.
Refer to the counter C116101 and the description of the counter
C10312 in Section TCHF Counters Explanation.
Calculation formula

C116103 = C116101 + C10312

C116104
Definition

Handover attempt due to uplink receiving strength (on TCH/F)


Description

Refer to the description of the counter C10812 in Section Handover


Cause Counters Explanation.
Calculation formula

C116104 = C10812

C116105
Definition

Handover attempt due to downlink receiving level(on TCH/F)


Description

Refer to the description of the counter C10813 in Section Handover


Cause Counters Explanation.
Calculation formula

C116105 = C10813

C116106
Definition

Handover attempt due to uplink interference (on TCH/F)


Description

Confidential and Proprietary Information of ZTE CORPORATION 35


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Refer to the description of the counter C10814 in Section Handover


Cause Counters Explanation.
Calculation formula

C116106 = C10814

C116107
Definition

Handover attempt due to downlink interference (on TCH/F)


Description

Refer C10815.
Calculation formula

C116107 = C10815

C116108
Description

Handover attempt due to C/I RATIO concentric cells (on TCH/F)


Definition

Refer to the description of the counter C10814 in Section Handover


Cause Counters Explanation.
Calculation formula

C116108 = C10816

C116109
Definition

Handover attempt due to PBGT (on TCH/F)


Description

Refer to the description of the counter C10817 in Section Handover


Cause Counters Explanation.
Calculation formula

C116109 = C10817

C116110
Definition

Handover attempt due to large TA (on TCH/F)


Description

36 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 - Key Performance Indicators

Refer to the description of the counter C10818 in Section Handover


Cause Counters Explanation.
Calculation formula
C116110 = C10818

C116111
Definition

Handover attempt due to uplink quality (on TCH/F)


Description

Refer to the description of the counter C10836 in Section Handover


Cause Counters Explanation.
Calculation formula

C116111 = C10836

C116112
Definition

Handover attempt due to downlink quality (on TCH/F)


Description

Refer to the description of the counter C10837 in Section Handover


Cause Counters Explanation.
Calculation formula

C116112 = C10837

C116113
Definition

Handover attempt due to other factors (on TCH/F)


Description

Refer to the description of the counter C10821 in Section Handover


Cause Counters Explanation.
Calculation formula

C116113 = C10821

C116114
Definition

Number of uplink signal samples with RQ = 0


Description

Confidential and Proprietary Information of ZTE CORPORATION 37


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Refer to the description of the counter C10821 in Section Handover


Cause Counters Explanation.
Calculation formula

C116114 = C10821

C116130
Definition

Number of call drops due to inter-BSC handover failure


Description

It represents the number of call drops due to Intra-MSC inter-cell


handover failure. It is the number of call drops due to all handover
minus call drops due to intra-BSC handover.
Refer to the description of the counter C11715 in Section TCHF
Counters Explanation.
Calculation formula

C116130 = C11624 - C11715

C116131
Definition

Total TCH/H busy time


Description

It represents total seize time of each TCH/H in a cell. Total number of


seize TCH/H in a cell shows TCH/H traffic in that cell.
Refer to the description of the counter C11715 in Section Resource
Availability Counters Explanation.
Calculation formula

C116131 = C11511

38 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2

BTS Measurement

This chapter covers the following topics:

Power Control Measurement


TRX Service Measurement
Paging Messages Measurement
TRX Basic Measurement
TRX Power & Temperature Measurement

Power Control Measurement


Power Control enables the mobile station and/or the BTS to increase or
decrease the transmission power on a per-radio link basis.

Power Control is separately performed for the uplink and downlink. In both
cases the BSC is responsible for initiating Power Control; the mobile
station and the BTS adopt transmit power according to the BSC Power
Control commands.

Two modes of power control are:

Normal power control


Rapid power control
Amplitude of power adjustment in rapid control is greater than normal
power control.

BTS regularly samples the power of MS and BTS itself, to obtain average
power. BTS regularly reports the average power to BSC through PC TEST
RPT message, for power control. Measurement report helps in analyzing
the coverage quality as well as the effect and rate of power control.

Confidential and Proprietary Information of ZTE CORPORATION 39


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

FIGURE 1 - POWER CONTROL PROCESS

MS BTS: TRX BSC

Power control for MS

A1

Power control for TRX

A2
Regularly scan
power of MS and
BTS

A3
PC TEST RPT

B1

Table 6 lists power control measurement counters.

Power Control Counters


TABLE 6 POWER CONTROL COUNTERS

Counter No. Counter definition


Number of normal increase in MS power due to uplink signal
C00001
level
C00002 Number of rapid increase in MS power due to uplink signal level
Number of normal decrease in MS power due to uplink signal
C00003
level
C00004 Number of rapid decrease in MS power due to uplink signal level
Number of normal increase in BTS power due to downlink signal
C00005
level
Number of rapid increase in BTS power due to downlink signal
C00006
level
Number of normal decrease in BTS power due to downlink signal
C00007
level
Number of rapid decrease in power BTS due to downlink signal
C00008
level
Number of normal increase in MS power due to uplink signal
C00009
quality
Number of rapid increase in MS power due to uplink signal
C00010
quality
Number of normal decrease in MS power due to uplink signal
C00011
quality
Number of rapid decrease in MS power due to uplink signal
C00012
quality

40 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - BTS Measurement

Counter No. Counter definition


Number of normal increase in BTS power due to downlink signal
C00013
quality
Number of rapid increase in BTS power due to downlink signal
C00014
quality
Number of normal decrease in BTS power due to downlink signal
C00015
quality
Number of rapid decrease in BTS power due to downlink signal
C00016
quality
C00017 Total value of power scans of MS transmitting power
C00018 Number of power scans of MS transmitting power
C00019 Total value of power scans of BTS power
C00020 Number of power scans of BTS power
C00021 Total value of power scans of downlink signal level
C00022 Number of power scans of downlink signal level
C00023 Total value of power scans of uplink signal level
C00024 Number of power scans of uplink signal level
C00025 Total value of power scans of downlink signal quality
C00026 Number of power scans of downlink signal quality
C00027 Total value of power scans of uplink signal quality
C00028 Number of power scans of uplink signal quality

Power Control Counters Explanation


C00001
Definition

Number of normal increase in MS power due to uplink signal level


Description

BTS periodically measures the uplink signal level. It calculates average


level value and sends this value to BSC. BSC compares the average
level value with threshold value and decides normal increase in MS
power according to the power control algorithm.
Measurement point

Normal increase in MS power at point A1 in FIGURE 1

C00002
Definition

Number of rapid increase in MS power due to uplink signal level


Description

Confidential and Proprietary Information of ZTE CORPORATION 41


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

BTS periodically measures the uplink signal level. It calculates average


level value and sends this value to BSC. BSC compares the average
level value with threshold value and decides rapid increase in MS
power according to the power control algorithm.
Measurement point

Rapid increase in MS power at point A1 in FIGURE 1

C00003
Definition

Number of normal decrease in MS power due to uplink signal level


Description

BTS periodically measures the uplink signal level. It calculates average


level value and sends this value to BSC. BSC compares the average
level value with threshold value and decides normal decrease in MS
power according to the power control algorithm.
Measurement point

Normal decrease in MS power at point A1 in FIGURE 1

C00004
Definition

Number of rapid decrease in MS power due to uplink signal level


Description

BTS periodically measures the uplink signal level. It calculates average


level value and sends this value to BSC. BSC compares the average
level value with threshold value and decides rapid decrease in MS
power according to the power control algorithm.
Measurement point

Rapid decrease in MS power at point A1 in FIGURE 1

C00005
Definition

Number of normal increase in BTS power due to downlink signal level


Description

BTS periodically receives measurement report of downlink signal level.


BSC compares the average level value with the threshold value and
decides normal increase in BTS power according to the power control
algorithm.

42 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - BTS Measurement

Measurement point

Normal increase in BTS power at point A2 in FIGURE 1

C00006
Definition

Number of rapid increase in BTS power due to downlink signal level


Description

BTS periodically receives measurement report of downlink signal level.


BSC compares the average level value with the threshold value and
decides rapid increase in BTS power according to the power control
algorithm.
Measurement point

Rapid increase in BTS power at point A2 in FIGURE 1

C00007
Definition

Number of normal decrease in BTS power due to downlink signal level


Description

BTS periodically receives measurement report of downlink signal level.


BSC compares the average level value with the threshold value and
decides normal decrease in BTS power according to the power control
algorithm.
Measurement point

Normal decrease in BTS power at point A2 in FIGURE 1

C00008
Definition

Number of rapid decrease in BTS power due to downlink signal level


Definition

BTS periodically receives measurement report of downlink signal level.


BSC compares the average level value with the threshold value and
decides rapid decrease in BTS power according to the power control
algorithm.
Measurement point

Rapid decrease in BTS power at point A2 in FIGURE 1

Confidential and Proprietary Information of ZTE CORPORATION 43


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C00009
Definition

Number of normal increase in MS power due to uplink signal quality


Description

BTS periodically measures the uplink signal quality. It calculates


average quality value and sends this value to BSC. BSC compares the
average quality value with threshold value and decides normal increase
in MS power according to the power control algorithm.
Measurement point

Normal increase in MS power at point A1 in FIGURE 1

C00010
Definition

Number of rapid increase in MS power due to uplink signal quality


Description

BTS periodically measures the uplink signal quality. It calculates


average quality value and sends this value to BSC. BSC compares the
average quality value with threshold value and decides rapid increase
in MS power according to the power control algorithm.
Measurement Point

Rapid increase in MS power at point A1 in FIGURE 1

C00011
Definition

Number of normal decrease in MS power due to uplink signal quality


Description

BTS periodically measures the uplink signal quality. It calculates


average quality value and sends this value to BSC. BSC compares the
average quality value with threshold value and decides normal
decrease in MS power according to the power control algorithm.
Measurement Point

Normal decrease in MS power at point A1 in FIGURE 1

C00012
Definition

Number of rapid decrease in MS power due to uplink signal quality

44 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - BTS Measurement

Description

BTS periodically measures the uplink signal quality. It calculates


average quality value and sends this value to BSC. BSC compares the
average quality value with threshold value and decides rapid decrease
in MS power according to the power control algorithm.
Measurement Point

Rapid decrease in MS power at point A1 in FIGURE 1

C00013
Definition

Number of normal increase in BTS power due to downlink signal quality


Description

BTS periodically receives measurement report of downlink signal


quality from MS. BSC compares the average of received measurement
values with threshold value and decides normal increase in BTS power
according to the power control algorithm.
Measurement Point

Normal increase in BTS power at point A2 in FIGURE 1

C00014
Definition

Number of rapid increase in BTS power due to downlink signal quality


Description

BTS periodically receives measurement report of downlink signal


quality from MS. BSC compares the average of received measurement
values with threshold value and decides rapid increase in BTS power
according to the power control algorithm.
Measurement Point

Rapid increase in BTS power at point A2 in FIGURE 1

C00015
Definition

Number of normal decrease in BTS power due to downlink signal


quality
Description

BTS periodically receives measurement report of downlink signal


quality from MS. BSC compares the average of received measurement
values with threshold value and decides normal decrease in BTS power
according to the power control algorithm.

Confidential and Proprietary Information of ZTE CORPORATION 45


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Measurement Point

Normal decrease Rapid increase in BTS power at point A2 in FIGURE 1

C00016
Definition

Number of rapid decrease in BTS power due to downlink signal quality


Description

BTS periodically receives measurement report of downlink signal


quality from MS. BSC compares the average of received measurement
values with threshold value and decides rapid decrease in BTS power
according to the power control algorithm.
Measurement Point

Rapid decrease Rapid increase in BTS power at point A2 in FIGURE 1

C00017
Definition

Total value of power scans of MS transmitting power


Description

BTS periodically measures the MS transmitting power and accumulates


each power scan value in this counter. Value of this counter is used to
calculate the average value, which BTS sends to BSC for power control.
Measurement Point

Accumulation occurs at point A3 in FIGURE 1

C00018
Definition

Number of power scans of MS transmitting power


Description

BTS periodically measures the MS transmitting power. This counter


represents the number of power scans of MS transmitting power. Each
time BTS accumulates the power scan values, value of this counter
increment by one.
Measurement Point

Accumulation occurs at point A3 in FIGURE 1

46 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - BTS Measurement

C00019
Definition

Total value of power scans of BTS power


Description
BTS periodically measures its own power and accumulates the power
scan values in this counter. Value of this counter is used to calculate
the average value, which BTS sends to BSC for power control.
Measurement Point

Accumulation occurs at point A3 in FIGURE 1

C00020
Definition

Number of power scans of BTS power


Description

BTS periodically measures its own power. This counter represents the
number of BTS power scans. Each time BTS accumulates the power
scan values, this counter increment by one.
Measurement Point

Accumulation occurs at point A3 in FIGURE 1

C00021
Definition

Total value of power scans of downlink signal level


Description

BTS periodically measures the downlink signal level through


information received from MS. MS sends the received signal level
information to BTS for power control. This counter contains total value
of number of downlink power scans.
Measurement Point

Accumulation occurs at point A3 in FIGURE 1

C00022
Definition

Number of power scans of downlink signal level


Description

BTS periodically measures the downlink signal level through


information received from MS. MS sends the received signal level

Confidential and Proprietary Information of ZTE CORPORATION 47


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

information to BTS for power control. This counter represents the


number of downlink power scans. Each time BTS accumulates the
power scan values, value of this counter increment by one.
Measurement Point

Accumulation occurs at point A3 in FIGURE 1

C00023
Definition

Total value of power scans of uplink signal level


Description

BTS periodically measures the uplink signal level and accumulates all
the power scan values in this counter. Value of this counter is used to
calculate the average power, which BTS sends to BSC for power control.
Measurement Point

Accumulation occurs at point A3 in FIGURE 1

C00024
Definition

Number of power scans of uplink signal level


Description

BTS periodically measures the uplink signal level. This counter


represents the number of uplink power scans to measure uplink signal
level. Each time BTS accumulates the power scan values, value of this
counter increment by one.
Measurement Point

Accumulation occurs at point A3 in FIGURE 1

C00025
Definition

Total value of power scans of downlink signal quality


Description

BTS periodically measures the downlink signal quality through


information received from MS. MS send the received signal quality
information to BTS for power control. This counter represents the
number of downlink power scans. Each time BTS accumulates the
power scan values, value of this counter increment by one.
Measurement Point

Accumulation occurs at point A3 in FIGURE 1

48 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - BTS Measurement

C00026
Definition

Number of power scans of downlink signal quality


Description

BTS periodically measures the downlink signal quality through


information received from MS. MS send the received signal quality
information to BTS for power control. This counter represents the
number of downlink power scans. Each time BTS accumulates the
power scan values, value of this counter increment by one.
Measurement Point

Accumulation occurs at point A3 in FIGURE 1

C00027
Definition

Total value of power scans of uplink signal quality


Description

BTS periodically measures the uplink signal quality and accumulates all
the power scan values in this counter. Value of this counter is used to
calculate the average power, which BTS sends to BSC for power control.
Measurement Point

Accumulation occurs at point A3 in FIGURE 1

C00028
Number of power scans of uplink signal quality
Description

BTS periodically measures the uplink signal quality. This counter


represents the number of uplink power scans to measure uplink signal
quality. Each time BTS accumulates the power scan values, value of
this counter increment by one.
Measurement point

Accumulation occurs at point A3 in FIGURE 1

TRX Service Measurement


TRX Service Measurement provides statistics of all the events relating TRX.
It involves the measurement counters, which keeps the statistics such as:

Channel Activation

Confidential and Proprietary Information of ZTE CORPORATION 49


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Channel Deactivation
Handover Success
Handover Failure
Carrier Frequency interference band
Maximum and minimum uplink signal level
Maximum and minimum downlink signal level
Table 7 lists all TRX Service counters.

TRX Service Counters


TABLE 7 TRX SERVICE COUNTERS

Counter No. Counter Definition


C00029 Number of intra-cell handover in attempts
C00030 Number of successful intra-cell handover ins
C00031 Number of Intra-BSC inter-cell handover in attempts
C00032 Number of successful Intra-BSC inter-cell handover ins
C00033 Number of Intra-MSC inter-cell handover in attempts
C00034 Number of successful Intra-MSC inter-cell handover ins
C00035 Total TCH busy time of
C00036 Total number of TCH seizures (including handover)
C00037 Total number of call drops due to TCH LAPD breakage
C00038 Number of call drops due to TCH wireless link failure
C00039 Total number of TCH handover call drops
C00040 Number of TCH/F activation attempts (including handover)
C00041 Number of successful TCH/F activations (including handover)
C00042 Number of TCH/F assignment attempts
C00043 Number of TCH/F assignment successes
C00044 Number of TCH/H activation attempts (including handover)
C00045 Number of successful TCH/H activations (including handover)
C00046 Number of TCH/H assignment attempts
C00047 Number of TCH/H assignment successes
C00048 Total SDCCH busy time
C00049 Total number of SDCCH call attempts
C00050 Total number of SDCCH call drops
C00051 Number of SDCCH activation attempts (including handover)
C00052 Number of SDCCH activation successes (including handover)
C00053 Number of SDCCH assignment attempts
C00054 Number of successful SDCCH assignments

50 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - BTS Measurement

Counter No. Counter Definition


C00055 Number of samples with uplink RQ = 0
C00056 Number of samples with uplink RQ = 1
C00057 Number of samples with uplink RQ = 2
C00058 Number of samples with uplink RQ = 3
C00059 Number of samples with uplink RQ = 4
C00060 Number of samples with uplink RQ = 5
C00061 Number of samples with uplink RQ = 6
C00062 Number of samples with uplink RQ = 7
C00063 Number of samples with downlink RQ = 0
C00064 Number of samples with downlink RQ = 1
C00065 Number of samples with downlink RQ = 2
C00066 Number of samples with downlink RQ = 3
C00067 Number of samples with downlink RQ = 4
C00068 Number of samples with downlink RQ = 5
C00069 Number of samples with downlink RQ = 6
C00070 Number of samples with downlink RQ = 7
C00071 Mean number of idle TCH/Fs with interference band 0
C00072 Mean number of idle TCH/Fs with interference band 1
C00073 Mean number of idle TCH/Fs with interference band 2
C00074 Mean number of idle TCH/Fs with interference band 3
C00075 Mean number of idle TCH/Fs with interference band 4
C00076 Mean number of idle TCH/Fs with interference band 5
C00077 Mean number of idle TCH/Hs with interference band 0
C00078 Mean number of idle TCH/Hs with interference band 1
C00079 Mean number of idle TCH/Hs with interference band 2
C00080 Mean number of idle TCH/Hs with interference band 3
C00081 Mean number of idle TCH/Hs with interference band 4
C00082 Mean number of idle TCH/Hs with interference band 5
C00083 Mean number of idle SDCCHs with interference band 0
C00084 Mean number of idle SDCCHs with interference band 1
C00085 Mean number of idle SDCCHs with interference band 2
C00086 Mean number of idle SDCCHs with interference band 3
C00087 Mean number of idle SDCCHs with interference band 4
C00088 Mean number of idle SDCCHs with interference band 5
C00089 Maximum value obtained in regular scan of uplink signal level
C00090 Minimum value obtained in regular scan of uplink signal level
C00091 Maximum value obtained in regular scan of downlink signal level

Confidential and Proprietary Information of ZTE CORPORATION 51


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Counter No. Counter Definition


C00092 Minimum value obtained in regular scan of downlink signal level

TRX Service Counters Explanation


C00029
Definition

Number of intra-cell handover in attempts


Description

Intra-cell handover triggers due to receiving signal level, receiving


quality level, interference and concentric cell. In intra-cell handover,
source cell and target cell are same. During intra-cell handover,
initially BSC sends CHANEL ACTIVATE message to destination channel.
Then BTS sends CHANNEL ACTIVATE ACK message to BSC.

FIGURE 2 - INTRA CELL HANDOVER PROCESS

MS BTS:TRX BSC

CHANNEL ACTIVATE

CHANNEL ACTIVATE ACK

A1
ASSIGNMENT COMMAND

ASSIGNMENT COMPLETE

A2

Measurement Point

Counter starts when BSC receives Channel Activation Acknowledgment.


Refer point A1 as shown in F I G U R E 2 .

C00030
Definition

Number of successful intra-cell handover-ins


Description

After successful activation of destination channel, BSC sends


ASSIGNMENT COMMAND message to MS on source channel. When BSC

52 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - BTS Measurement

receives ASSIGNMENT COMPLETE message from MS on destination


channel, it indicates successful intra-cell handover.
Measurement Point

Refer point A2 as shown in FIGURE 2.

C00031
Definition

Number of Intra-BSC inter-cell handover in attempts


Description

In Intra-BSC inter-cell handover, source cell and target cell are


different but lay under one BSC. During inter-cell handover, initially
BSC sends CHANNEL ACTIVATE message to destination channel.

FIGURE 3 - INTRA BSC HANDOVER PROCESS

MS Old BTS: New BTS BSC

CHANNEL ACT

CHANNEL ACT ACK

A1
HANDOVER COMMAND HANDOVER COMMAND

HANDOVER COMPLETE HANDOVER COMPLETE

A2

Measurement Point

Refer point A1 as shown in FIGURE 3.

C00032
Definition

Number of successful Intra-BSC inter-cell handover-ins


Description

After successful activation of destination channel, BSC sends


HANDOVER COMMAND message to MS on source channel. When BSC
receives HANDOVER COMPLETE message from MS on destination
channel, it indicates successful intra-BSC inter-cell handover.

Confidential and Proprietary Information of ZTE CORPORATION 53


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Measurement Point

Refer point A1 as shown in FIGURE 3.

C00033
Definition

Number of Intra-MSC inter-cell handover in attempts


Description

Intra-MSC inter-cell handover means handover initiation when BSC


receives HANDOVER REQUEST message from MSC. Initially BSC
receives HANDOVER REQUEST message form MSC. Then BSC sends
CHANNEL ACTIVATE message to destination channel.
Measurement Point

After BSC receive CHANNEL ACTIVATE ACK message, value of this


counter increments. Refer point A1 as shown in FIGURE 3.

C00034
Definition

Number of successful Intra-MSC inter-cell handover-ins


Description

After BSC successfully activates the destination channel, it receives


HANDOVER COMPLETE message from MS, which indicates successful
intra-MSC inter-cell handover.
Measurement Point

After successful handover, counter value increments. Refer point A2 as


shown in FIGURE 3.

C00035
Definition

Total TCHs busy time


Description

It represents the total time for which MSs seizes the TCHs on TRX.
TCHs comprise TCH/Fs and TCH/Hs. C00035 represents TRX traffic.
Measurement Point

Counter increments when:


MS seizes TCH successfully.
MS release TCH.
During timely measurement.

54 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - BTS Measurement

Reported measurement value is accumulation of each measurement


value. After each measurement, current time is set as last time for the
next measurement. When MS seizes TCH successfully, number of
seized TCHs increments by one. When MS releases TCH, number of
seized TCHs decrements by one.
Measurement formula:

(Current time – time of last measurement) X (number of seized TCHs)

C00036
Definition

Total number of TCHs seizures (including handover)


Description

C00036 represents total number of TCH seizures on TRX. TCHs


comprise both TCH/Fs and TCH/Hs.
Measurement Point

Counter increments upon successful TCHs seizures.

C00037
Definition

Total number of TCH LAPD call drops


Description

C00037 represents call drops due to LAPD link break.


Measurement Point

Counter increments when BSC receives LADP broken message.

C00038
Definition

Number of call drops due to TCH wireless link failure.


Description

C00038 represents call drops due to wireless link failure. Wireless link
fails due to poor signal level and handover is not possible.
Measurement Point

Counter increments at reception of wireless link failure message.

C00039
Definition

Total number of TCH handover call drops

Confidential and Proprietary Information of ZTE CORPORATION 55


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Description

C0039 represents call drops due to handover failure. During intra-cell


handover, if BSC does not receive ASSIGNMENT COMPLETE message in
guard period, handover fails. During Intra-BSC handover, if BSC does
not receive HANDOVER COMPLETE message in guard period, handover
fails.

FIGURE 4 - INTER-CELL HANDOVER FAILURE PROCESS

MS Old BTS: New BTS BSC

CHANNEL ACT

CHANNEL ACT ACK

A1
HANDOVER COMMAND HANDOVER COMMAND
SET T3103

T3103
Timeout

A2

FIGURE 5 - INTRA CELL HANDOVER FAILURE PROCESS

MS BTS:TRX BSC

CHANNEL ACTIVATE

CHANNEL ACTIVATE ACK

A1
ASSIGNMENT COMMAND
SET T3107

T3107
Timeout

A2

Measurement Point

Counter increments when BSC receives T3103 or T3107 expiry


message. Refer point A2 in FIGURE 4 and point A2 in FIGURE 5.

C00040
Definition

Number of TCH/F activation attempts (including handover)

56 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - BTS Measurement

Description

C00040 represents number of TCH/Fs activation attempts on TRX,


when CHANNEL ACTIVATE message is send.
Measurement Point

C00040 increments when BSC sends CHANNEL ACTIVATION message


to BTS. Refer to FIGURE 1.

C00041
Definition

Number of successful TCH/F activations (including handover)


Description

C00041 represents number of successful TCH/F activations on TRX.


Measurement Point

C00041 increments when BSC receives CHANNEL ACTIVATE ACK


message.

C00042
Definition

Number of TCH/F assignment attempts


Description

BSC sends an ASSIGNMENT COMMAND message to assign TCH/F.


Measurement Point

C00042 increments when BSC sends ASSIGNMENT COMMAND


message to BTS.

C00043
Definition

Number of successful TCH/F assignments.


Description

BSC sends an ASSIGNMENT COMMAND message to assign TCH/F. After


the BSC receives the EST IND or ASSIGNMENT COMPLETE message,
indicates successful channel assignment.
Measurement Point

C00043 increments when BSC receives EST IND or ASSIGNMENT


COMPLETE message.

Confidential and Proprietary Information of ZTE CORPORATION 57


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C00044
Definition

Number of TCH/H activation attempts (including handover)


Description

C00044 represents number of TCH/Hs activation attempts on TRX.


Measurement Point

C00044 increments when the BSC sends the CHANNEL ACTIVATE


message to BTS.

C00045
Definition

Number of successful TCH/H activations (including handover)


Description

C00045 represents number of successful TCH/H activations on TRX.


Measurement Point

C00045 increments when BSC receives CHANNEL ACTIVATE ACK


message.

C00046
Definition

Number of TCH/H assignment attempts


Description

BSC sends an ASSIGNMENT COMMAND message to assign TCH/H.


Measurement Point

C00046 increments when BSC sends ASSIGNMENT COMMAND


message to BTS.

C00047
Definition

Number of successful TCH/H assignments


Description

BSC sends an ASSIGNMENT COMMAND message to assign a TCH/H.


After BSC receives EST IND or ASSIGNMENT COMPLETE message,
indicates successful TCH/H assignment.
Measurement Point

58 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - BTS Measurement

C00047 increments when BSC receives EST IND or ASSIGNMENT


COMPLETE message.

C00048
Definition

Total SDCCHs busy time


Description

C00048 represents total time of SDCCHs seizures on TRX. It includes


both assignment and handover. C00048 shows traffic of SDCCHs on
TRX.
Measurement Point
C00048 increments when:
MS seizes SDCCH successfully.
MS releases SDCCH.
During timely measurement.
Reported measurement value is accumulation of each measurement
value. After each measurement, current time is set as last time for the
next measurement. When MS seizes SDCCH successfully, number of
seized SDCCH increments by one. When MS releases SDCCH, number
of seized SDCCH decrements by one.
Measurement formula:

(Current time – time of last measurement) X (Number of seized


SDCCHs)

C00049
Definition

Total number of SDCCH call attempts


Description

Total number of SDCCH call attempts = Number of successful SDCCH


seizers + Number of unsuccessful SDCCH seizers
Measurement Point

C00049 increments for each successful or unsuccessful SDCCH seizer

C00050
Definition

Total number of SDCCH call drops


Description

SDCCH call drops due to following causes:

Confidential and Proprietary Information of ZTE CORPORATION 59


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

T3103 expires in case of inter-cell handover (FIGURE 4)


T3107 expires in case of intra-cell handover (FIGURE 5)
T8 expires in case of external handover (FIGURE 6)

FIGURE 6 - T8 TIMEOUT

MS Old BTS: New BTS BSC

CHANNEL ACT

CHANNEL ACT ACK

A1
HANDOVER COMMAND HANDOVER COMMAND
SET T3103

T3103
Timeout

A2

C00050 increments when:


BSC receives LAPD link break message on SDCCH.
BSC receives connection failure message and the channel is an SDCCH.
T8 expires.
T3103 expires.
T3107 expires.

C00051
Definition

Number of SDCCH activation attempts (including handover)


Description

C00051 represents number of SDCCHs activation attempts on TRX


when CHANNEL ACTIVATE message is send.
Measurement Point

Counter increments when BSC sends CHANNEL ACTIVATE message to


BTS.

C00052
Definition

Number of successful SDCCH activations (including handover)

60 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - BTS Measurement

Definition

C00052 represents number of successful SDCCH activations on TRX.


Measurement Point

C00052 increments when BSC receives CHANNEL ACTIVATE ACK


message.

C00053
Definition

Number of SDCCH assignment attempts


Description

BSC sends an IMMEDIATE ASSIGNMENT or ASSIGNMENT COMMAND


message to assign an SDCCH.
Measurement Point

C00053 increments when BSC sends IMMEDIATE ASSIGNMENT or


ASSIGNMENT COMMAND message to BTS.

C00054
Definition

Number of successful SDCCH assignments


Description

BSC sends an IMMEDIATE ASSIGNMENT or ASSIGNMENT COMMAND


message to assign an SDCCH. After BSC receives EST IND (CM SERV
REQ) or ASSIGNMENT COMPLETE message, indicates successful
channel assignment.
Measurement Point

C00054 increments when BSC receives EST IND (CM SERV REQ) or
ASSIGNMENT COMPLETE message.

C00055
Definition

Number of samples with uplink RQ = 0


Description

BTS measures level, quality and interference of uplink signals through


measurement report from MS. BTS sends measurement report to BSC
after every multi frame (480ms). The measurement value is the
number of samples with uplink RQ = 0 in the measurement report.
Measurement Point

C00055 increments when BSC receives uplink samples with RQ=0

Confidential and Proprietary Information of ZTE CORPORATION 61


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C00056
Definition

Number of samples with uplink RQ = 1


Description

C00056 represents number of samples with uplink RQ = 1 in


measurement report.
Measurement Point

C00056 increments when BSC receives uplink samples with RQ=1

C00057
Definition

Number of samples with uplink RQ = 2


Description

C00057 represents number of samples with uplink RQ = 2 in


measurement report.
Measurement Point

C00057 increments when BSC receives uplink samples with RQ=2

C00058
Definition

Number of samples with uplink RQ = 3


Description

C00058 represents number of samples with uplink RQ = 3 in


measurement report.
Measurement Point
C00058 increments when BSC receives uplink samples with RQ=3

C00059
Definition

Number of samples with uplink RQ = 4


Description

C00059 represents number of samples with uplink RQ = 4 in


measurement report.
Measurement Point

C00059 increments when BSC receives uplink samples with RQ=4

62 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - BTS Measurement

C00060
Definition

Number of samples with uplink RQ = 5


Description

C00060 represents number of samples with uplink RQ = 5 in


measurement report.
Measurement Point

C00060 increments when BSC receives uplink samples with RQ=5

C00061
Definition

Number of samples with uplink RQ = 6


Description

C00061 represents number of samples with uplink RQ = 6 in


measurement report.
Measurement Point

C00061 increments when BSC receives uplink samples with RQ=6

C00062
Definition

Number of samples with uplink RQ = 7


Definition

C00062 represents number of samples with uplink RQ = 7 in


measurement report.
Measurement Point

C00062 increments when BSC receives uplink samples with RQ=7

C00063
Definition

Number of samples with downlink RQ = 0


Description

C00063 represents number of samples with downlink RQ = 0 in


measurement report.
Measurement Point

C00063 increments when BSC receives downlink samples with RQ=0

Confidential and Proprietary Information of ZTE CORPORATION 63


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C00064
Definition

Number of samples with downlink RQ = 1


Description

C00064 represents number of samples with downlink RQ = 1 in


measurement report.
Measurement Point

C00064 increments when BSC receives downlink samples with RQ=1

C00065
Definition

Number of samples with downlink RQ = 2


Description

C00065 represents number of samples with downlink RQ = 2 in


measurement report.
Measurement Point

C00065 increments when BSC receives downlink samples with RQ=2

C00066
Definition

Number of samples with downlink RQ = 3


Definition

C00066 represents number of samples with downlink RQ = 3 in


measurement report.
Measurement Point

C00066 increments when BSC receives downlink samples with RQ=3

C00067
Definition

Number of samples with downlink RQ = 4


Definition

C00067 represents number of samples with downlink RQ = 4 in


measurement report.
Measurement Point

C00067 increments when BSC receives downlink samples with RQ=4

64 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - BTS Measurement

C00068
Definition

Number of samples with downlink RQ = 5


Description

C00068 represents number of samples with downlink RQ = 5 in


measurement report.
Measurement Point

C00068 increments when BSC receives downlink samples with RQ=5

C00069
Definition

Number of samples with downlink RQ = 6


Description

C00069 represents number of samples with downlink RQ = 6 in


measurement report.
Measurement Point

C00068 increments when BSC receives downlink samples with RQ=6

C00070
Definition

Number of samples with downlink RQ = 7


Description
C00070 represents number of samples with downlink RQ = 7 in
measurement report.
Measurement Point

C00070 increments when BSC receives downlink samples with RQ=7

C00071
Definition

Mean number of idle TCH/Fs with interference band 0


Description

System regularly queries database to obtain Mean number of idle


TCH/Fs and various interference levels on TRX. System uses querying
point value to represent average value. System updates interference
band levels of TCH/Fs after BSC receives wireless resource indication
message from BTS. Measurement mechanisms of counters C00072 to

Confidential and Proprietary Information of ZTE CORPORATION 65


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C00088 is same as this counter. C00071 represents the Mean number


of idle TCH/Fs on TRX with interference band 0.
Measurement Point

Counter increments when database is queried regularly.

C00072
Definition

Mean number of idle TCH/Fs with interference band 1


Description

C00072 represents the mean number of idle TCH/Fs on TRX with


interference band 1.
Measurement Point

Counter increments when database is queried regularly.

C00073
Definition

Mean number of idle TCH/Fs with interference band 2


Description

C00073 represents the mean number of idle TCH/Fs on TRX with


interference band 2.
Measurement Point

Counter increments when database is queried regularly.

C00074
Definition

Mean number of idle TCH/Fs with interference band 3


Description

C00074 represents the mean number of idle TCH/Fs on TRX with


interference band 3.
Measurement Point

Counter increments when database is queried regularly.

C00075
Definition

Mean number of idle TCH/Fs with interference band


Description

66 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - BTS Measurement

C00075 represents the mean number of idle TCH/Fs on TRX with


interference band 4.
Measurement Point

Counter increments when database is queried regularly.

C00076
Definition

Mean number of idle TCH/Fs with interference band 5


Description

C00076 represents the mean number of idle TCH/Fs on TRX with


interference band 5.
Measurement Point

Counter increments when database is queried regularly.

C00077
Definition

Mean number of idle TCH/Hs with interference band 0


Description

C00077 represents the mean number of idle TCH/Hs on TRX with


interference band 0.
Measurement Point

Counter increments when database is queried regularly.

C00078
Definition

Mean number of idle TCH/Hs with interference band 1


Description

C00078 represents the mean number of idle TCH/Hs on TRX with


interference band1.
Measurement Point

Counter increments when database is queried regularly.

C00079
Definition

Mean number of idle TCH/Hs with interference band 2


Description

Confidential and Proprietary Information of ZTE CORPORATION 67


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C00079 represents the mean number of idle TCH/Hs on TRX with


interference band 2.
Measurement Point

Counter increments when database is queried regularly.

C00080
Definition

Mean number of idle TCH/Hs with interference band 3


Description

C00080 represents the mean number of idle TCH/Hs on TRX with


interference band 3.
Measurement Point

Counter increments when database is queried regularly.

C00081
Definition

Mean number of idle TCH/Hs with interference band 4


Description

C00081 represents the number of idle TCH/Hs on TRX with


interference band4.
Measurement Point

Counter increments when database is queried regularly.

C00082
Definition

Mean number of idle TCH/Hs with interference band 5


Description

C00082 represents the Mean number of idle TCH/Hs on TRX with


interference band 5.
Measurement Point

Counter increments when database is queried regularly.

C00083
Definition

Mean number of idle SDCCHs with interference band 0


Description

68 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - BTS Measurement

C00083 represents the Mean number of idle SDCCHs on TRX with


interference band 0
Measurement Point

Counter increments when database is queried regularly.

C00084
Definition

Mean number of idle SDCCHs with interference band 1


Description

C00084 represents the Mean number of idle SDCCHs on TRX with


interference band 1.
Measurement Point

Counter increments when database is queried regularly.

C00085
Definition

Mean number of idle SDCCHs with interference band 2


Description

C00085 represents the Mean number of idle SDCCHs on TRX with


interference band two.
Measurement Point

Counter increments when database is queried regularly.

C00086
Definition

Mean number of idle SDCCHs with interference band 3


Description

C00086 represents the Mean number of idle SDCCHs on TRX with


interference band three.
Measurement Point

Counter increments when database is queried regularly.

C00087
Definition

Mean number of idle SDCCHs with interference band 4


Description

Confidential and Proprietary Information of ZTE CORPORATION 69


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C00087 represents the number of idle SDCCHs on TRX with


interference band four.
Measurement Point

Counter increments when the database is queried regularly.

C00088
Definition

Mean number of idle SDCCHs with interference band 5


Description

C00088 represents the number of idle SDCCHs on TRX with


interference band 5.
Measurement Point

Counter increments when database is queried regularly.

C00089
Definition

Maximum value obtained in regular scan of uplink signal level


Description

C00089 represents maximum uplink signal value that BSC receives


among all the sample values for power control.
Measurement Point

Counter increments when BSC receives PC TEST RPT message.

C00090
Definition

Minimum value obtained in regular scan of uplink signal level


Description

C00090 represents minimum uplink signal value that BSC receives


among all the sample values for power control.
Measurement Point

Counter increments when BSC receives PC TEST RPT message.

C00091
Definition

Maximum value obtained in regular scan of downlink signal level


Description

70 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - BTS Measurement

C00091 represents maximum downlink signal value that BSC receives


among all the sample values for power control.
Measurement Point

Counter increments when BSC receives PC TEST RPT message.

C00092
Definition

Minimum value obtained in regular scan of downlink signal level


Description

C00092 represents maximum downlink signal value that BSC receives


among all the sample values for power control.
Measurement Point

Counter increments when BSC receives PC TEST RPT message.

Paging Messages Measurement


Paging messages measurement provides statistics of discard Circuit
Switched (CS) and Packet Switched (PS) paging messages due to full
queue length. Measurement unit is TRX.

Paging Messages Measurement Counters


Table 8 lists all paging messages measurement counters.

TABLE 8 PAGING MEASUREMENT COUNTERS

Counter No. Counter Definition


C01001 Number of PS paging message discarded because the queue is full
Number of CS paging message discarded because the queue is
C01002
full
C01003 Average length of CH queue: 9 x 9
C01004 Average length of PCH queue: 9 x 64

TRX Basic Measurement


TRX basic measurement provides statistics of time slot seizures in TRX.
TRX Basic Measurement Counters provides information such as time
duration and number of TCH and SDCCH seizures.

Confidential and Proprietary Information of ZTE CORPORATION 71


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

TRX Basic Measurement Counters


TABLE 9 COUNTERS OF CARRIER FREQUENCY-LEVEL BASIC MEASUREMENT

Counter No. Counter Definition


C13001 Seizure duration of TCHs
C13002 Number of TCH seizure
C13003 Seizure duration of SDCCHs
C13004 Number of SDCCH seizure

TRX Power &Temperature


Measurement
TRX temperature and TRX power is measured on TRU and reported to BSC
periodically.

TRX Power & Temperature Measurement


Counters
Table 10 lists all the TRX Temperature and Power measurement counters.

TABLE 10 TRX POWER AND TEMPERATURE COUNTERS

Counter Name Counter Definition


C14001 Maximum TRX power value
C14002 Minimum TRX power value
C14003 Mean TRX power value
C14004 Maximum TRX temperature value
C14005 Minimum TRX temperature value
C14006 Mean TRX temperature value

TRX Power & Temperature Measurement


Counters Explanation
C14001
Definition

Maximum TRX power value


Description

72 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2 - BTS Measurement

C14001 represents the maximum value of TRX power within the


measurement period. Measurement unit is dbm
Measurement Point

System collects the measurement from TRU.

C14002
Definition

Minimum value of TRX power


Description

C14002 represents the minimum value of TRX power within the


measurement period. Measurement unit is dbm.
Measurement Point

System collects the measurement from TRU.

C14003
Definition

Mean TRX power value


Description

It represents the mean value of TRX power within the measurement


period. Measurement unit is dbm.
Measurement Point

System collects the measurement from TRU.

C14004
Definition

Maximum TRX temperature value


Description

C14004 represents the maximum value of TRX temperature within the


measurement period. Measurement unit is Celsius.
Measurement Point

System collects the measurement from TRU.

C14005
Definition

Minimum TRX temperature value


Description

Confidential and Proprietary Information of ZTE CORPORATION 73


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C14005 represents the minimum value of TRX temperature within the


measurement period. Measurement unit is Celsius.
Measurement Point

System collects the measurement from TRU.

C14006
Definition

Mean TRX temperature value


Description

C14006 represents the mean value of TRX temperature within the


measurement period. Measurement unit is Celsius
Measurement Point

System collects the measurement from TRU.

74 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3

Wireless Channels

This chapter covers the following topics:

Channels Measurement

Channels Measurement
Channel Measurement here means wireless channel measurement in a cell,
as mobile communication is always through wireless medium. It refers to
the measurement of channel properties, which directly affects the Quality
of Service (QoS) in wireless communication, in a particular cell. Channel
properties such as received level, received quality, Timing Advance (TA)
and interference of both uplink and downlink signals. These measurements
are for the channels in busy or idle modes.

BTS sends MS measurement report to BSC every 480ms. BSC measures


uplink and downlink signal, TA and RQ value in a channel. BSC updates
interference band in database when it receives measurement report from
BTS.

Channels Counters
Table 11 lists all the Channel Measurement Counters.

TABLE 11 CHANNEL MEASUREMENT COUNTERS

Counter No. Counter Definition


C10701 Number of uplink signal quality samples in wireless channels
C10702 Level of worst uplink signal quality in wireless channels
C10703 Total value of uplink quality level values in wireless channels
C10704 Number of downlink signal quality samples in wireless channels
C10705 Level of worst downlink signal quality in wireless channels
Total value of downlink quality strength values in wireless
C10706
channels

Confidential and Proprietary Information of ZTE CORPORATION 75


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Counter No. Counter Definition


Number of received uplink signal strength samples in wireless
C10707
channels
C10708 Maximum received uplink signal strength in wireless channels
C10709 Minimum received uplink signal strength in wireless channels
C10710 Total value of uplink signal strength in wireless channels
Number of received downlink signal strength samples in wireless
C10711
channels
C10712 Maximum received downlink signal strength in wireless channels
C10713 Minimum downlink received signal strength in wireless channels
C10714 Total value of downlink signal strength in wireless channels
C10715 Number of TA samples in wireless channels
C10716 Maximum TA in wireless channels
C10717 Total number of TAs in wireless channels
C10718 Mean number of idle TCH/Fs with interference band 0
C10719 Mean number of idle TCH/Fs with interference band 1
C10720 Mean number of idle TCH/Fs with interference band 2
C10721 Mean number of idle TCH/Fs with interference band 3
C10722 Mean number of idle TCH/Fs with interference band 4
C10723 Mean number of idle TCH/Fs with interference band 5
C10724 Mean number of idle TCH/Hs with interference band 0
C10725 Mean number of idle TCH/Hs with interference band 1
C10726 Mean number of idle TCH/Hs with interference band 2
C10727 Mean number of idle TCH/Hs with interference band 3
C10728 Mean number of idle TCH/Hs with interference band 4
C10729 Mean number of idle TCH/Hs with interference band 5
C10730 Mean number of idle SDCCHs with interference band 0
C10731 Mean number of idle SDCCHs with interference band 1
C10732 Mean number of idle SDCCHs with interference band 2
C10733 Mean number of idle SDCCHs with interference band 3
C10734 Mean number of idle SDCCHs with interference band 4
C10735 Mean number of idle SDCCHs with interference band 5
C10736 Number of samples with uplink RQ = 0
C10737 Number of samples with uplink RQ = 1
C10738 Number of samples with uplink RQ = 2
C10739 Number of samples with uplink RQ = 3
C10740 Number of samples with uplink RQ = 4
C10741 Number of samples with uplink RQ = 5
C10742 Number of samples with uplink RQ = 6

76 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3 - Wireless Channels

Counter No. Counter Definition


C10743 Number of samples with uplink RQ = 7
C10744 Number of samples with downlink RQ = 0
C10745 Number of samples with downlink RQ = 1
C10746 Number of samples with downlink RQ = 2
C10747 Number of samples with downlink RQ = 3
C10748 Number of samples with downlink RQ = 4
C10749 Number of samples with downlink RQ = 5
C10750 Number of samples with downlink RQ = 6
C10751 Number of samples with downlink RQ = 7

Channels Counters Explanation


C10701
Definition

Number of uplink signal quality samples in wireless channels


Description

BTS sends measurement report of MS to BSC. BSC upon receiving the


measurement report does pre-processing. C10701 represents number
of uplink signal quality samples that BSC receives in measurement
report.
Measurement Point

C10701 increments when BSC receives the samples or preprocesses


the measurement report.

C10702
Definition

Level of worst uplink signal quality in wireless channels


Description

BTS sends measurement report of MS to BSC. BSC upon receiving the


measurement report does pre-processing. If uplink signal quality level
of wireless channels is lower than the lowest uplink quality level
recoded previously, this counter stores the new lowest value.
Measurement Point

C10702 increments when BSC receives the samples or preprocesses


the measurement report.

Confidential and Proprietary Information of ZTE CORPORATION 77


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C10703
Definition

Total value of uplink quality values in wireless channels


Description

C10703 accumulates uplink quality level values that BSC receives in


measurement report and represents the total value.
Measurement Point

C10703 increments when BSC receives the values or preprocesses the


measurement report.

C10704
Definition

Number of downlink signal quality samples in wireless channels


Description

BTS sends measurement report of MS to BSC. BSC upon receiving the


measurement report does pre-processing. C10704 represents number
of downlink signal quality samples that BSC receives in measurement
report.
Measurement Point

C10704 increments when BSC receives the samples or preprocesses


the measurement report.

C10705
Definition

Level of worst downlink signal quality in wireless channels


Description

BTS sends measurement report of MS to BSC. BSC upon receiving the


measurement report does pre-processing. If downlink signal quality
level of wireless channels is lower than the lowest downlink quality
level recoded previously, this counter stores the new lowest value.
Measurement Point

C10705 increments when BSC receives the samples or preprocesses


the measurement report.

C10706
Definition

Total value of downlink signal quality values in wireless channels

78 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3 - Wireless Channels

Description

C10706 accumulates downlink quality level values that BSC receives in


measurement report and represents total value.
Measurement Point

C10706 increments when BSC receives the values or preprocesses the


measurement report.

C10707
Definition

Number of received uplink signal strength samples in wireless channels


Description

BTS sends measurement report of MS to BSC. BSC upon receiving the


measurement report does pre-processing. C10707 represents number
of uplink signal strength samples that BSC receives in measurement
report.
Measurement Point

C10707 increments when BSC receives the samples or preprocesses


the measurement report.

C10708
Definition

Maximum received uplink signal strength in wireless channels


Description

If received uplink signal strength is higher than the previously record


maximum uplink signal strength, then this counter stores the new
value.
Measurement Point

C10708 increments when BSC receives the samples or preprocesses


the measurement report.

C10709
Definition

Minimum received uplink signal strength in wireless channels


Description

If received uplink signal level is lower than the previously record


maximum uplink signal level, then this counter stores the new value.

Confidential and Proprietary Information of ZTE CORPORATION 79


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Measurement Point

C10709 increments when BSC receives the samples or preprocesses


the measurement report.

C10710
Definition

Total value of uplink signal strength in wireless channels


Definition

C10710 accumulates the uplink receiving strength values that BSC


receives in the measurement report from MS and represents the total
value.
Measurement Point

C10710 increments when BSC receives the values or preprocesses the


measurement report.

C10711
Definition

Number of received downlink signal strength samples in wireless


channels
Description

BTS sends measurement report of MS to BSC. BSC upon receiving the


measurement report does pre-processing. C10711 represents number
of downlink signal strength samples that BSC receives in measurement
report.
Measurement Point

C10711 increments when BSC receives the values or preprocesses the


measurement report.

C10712
Definition

Maximum received downlink signal strength in wireless channels


Description

If received downlink signal strength is higher than the previously


record maximum downlink signal strength, then this counter stores the
new value.
Measurement Point

C10712 increments when BSC receives the values or preprocesses the


measurement report.

80 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3 - Wireless Channels

C10713
Definition

Minimum received downlink signal strength in wireless channels


Description

If received downlink signal strength is lower than the previously record


minimum downlink signal strength, then this counter stores the new
value.
Measurement Point

C10713 increments when BSC receives the values or preprocesses the


measurement report.

C10714
Definition

Total value of downlink signal strength in wireless channels


Description

C10714 accumulates the downlink receiving strength values that BSC


receives in the measurement report from MS and represents the total
value.
Measurement Point

C10714 increments when BSC receives the values or preprocesses the


measurement report.

C10715
Definition

Number of TA samples in wireless channels


Description

C10715 represents total number of TA samples that BSC receives in


the measurement report of MS.
Measurement Point

C10715 increments when BSC receives the values or preprocesses the


measurement report.

C10716
Definition

Maximum TA in wireless channels

Confidential and Proprietary Information of ZTE CORPORATION 81


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Description

If TA in the measurement report is greater than the maximum TA in


the previous record, this counter stores the new value.
Measurement Point

C10716 increments when BSC receives the values or preprocesses the


measurement report.

C10717
Definition

Total number of TAs in wireless channels


Description

C10717 accumulates TA in measurement report and obtains total TA in


wireless channels.
Measurement Point

C10717 increments when BSC receives the values or preprocesses the


measurement report.

For counters C10718~C10751, refer to TRX Service Counters Explanation.

C10718
Definition

Mean number of idle TCH/Fs with interference band 0

C10719
Definition

Mean number of idle TCH/Fs with interference band 1

C10720
Definition

Mean number of idle TCH/Fs with interference band 2

C10721
Definition

Mean number of idle TCH/Fs with interference band 3

C10722
Description

82 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3 - Wireless Channels

Mean number of idle TCH/Fs with interference band 4

C10723
Definition

Mean number of idle TCH/Fs with interference band 5

C10724
Definition

Mean number of idle TCH/Hs with interference band 0

C10725
Definition

Mean number of idle TCH/Hs with interference band 1

C10726
Definition

Mean number of idle TCH/Hs with interference band 2

C10727
Definition

Mean number of idle TCH/Hs with interference band 3

C10728
Definition

Mean number of idle TCH/Hs with interference band 4

C10729
Definition

Mean number of idle TCH/Hs with interference band 5

C10730
Definition

Mean number of idle SDCCHs with interference band 0

Confidential and Proprietary Information of ZTE CORPORATION 83


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C10730
Definition

Mean number of idle SDCCHs with interference band 0

C10731
Definition

Mean number of idle SDCCHs with interference band 1

C10732
Definition

Mean number of idle SDCCHs with interference band 2

C10733
Definition

Mean number of idle SDCCHs with interference band 3

C10734
Definition

Mean number of idle SDCCHs with interference band 4

C10735
Definition

Mean number of idle SDCCHs with interference band 5

C10736
Definition

Number of samples with uplink RQ = 0

C10737
Definition

Number of samples with uplink RQ = 1

C10738
Definition

Number of samples with uplink RQ = 2

84 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3 - Wireless Channels

C10739
Definition

Number of samples with uplink RQ = 3

C10740
Definition

Number of samples with uplink RQ = 4

C10741
Definition

Number of samples with uplink RQ = 5

C10742
Definition

Number of samples with uplink RQ = 6

C10743
Definition

Number of samples with uplink RQ = 7

C10744
Definition

Number of samples with downlink RQ = 0

C10745
Definition

Number of samples with downlink RQ = 1

C10746
Definition

Number of samples with downlink RQ = 2

C10747
Description

Number of samples with downlink RQ = 3

Confidential and Proprietary Information of ZTE CORPORATION 85


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C10748
Definition

Number of samples with downlink RQ = 4

C10749
Definition

Number of samples with downlink RQ = 5

C10750
Definition

Number of samples with downlink RQ = 6

C10751
Definition

Number of samples with downlink RQ = 7

86 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4

Random Access

This chapter covers the following topics:

Random Access Measurement

Random Access Measurement


Random access measurement provides statistics such as number of:

Random access attempts

Random access processes

Successful random accesses

For random access slot-aloha is used as an access protocol. Single access


may have multiple random access requests.

Random access success ratio means of number of successful random


accesses divided by successful random access requests. This ratio reflects
the channel blocking status.

Collision may occur between numbers of random access requests, for


which time interval adjustment is required.

FIGURE 5 illustrates the Random Access Process.

Random Access Counters


Table 12 lists all the random access counters.

TABLE 12 RANDOM ACCESS COUNTERS

Counter No. Counter Definition


C10001 Number of invalid access requests
C10002 Number of Mobile Originated Call (MOC) random access attempts
C10003 Number of successful random access processes due to MOC

Confidential and Proprietary Information of ZTE CORPORATION 87


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Counter No. Counter Definition


attempts

C10004 Number of successful random accesses due to MOC


C10005 Number of Mobile Terminated Call (MTC) random access attempts
Number of successful random access processes due to MTC
C10006
attempts
C10007 Number of successful random accesses due to MTC
C10008 Number of random access attempts due to call re-establishment.
Number of successful random access processes due to call re-
C10009
establishment
C10010 Number of successful random accesses due to call re-establishment
C10011 Number of random access attempts due to emergency calls
Number of successful random access processes due to emergency
C10012
calls
C10013 Number of successful random accesses due to emergency calls
C10014 Number of random access attempts due to LOC
C10015 Number of successful random access processes due LOC
C10016 Number of successful random accesses due to LOC
C10017 Number of random access attempts for other causes
C10018 Number of successful random access processes for other causes
C10019 Number of successful random accesses for other causes
C10020 Number of wireless channel accesses due to location update
C10021 Number of wireless channel accesses due to call originations
C10022 Number of wireless channel accesses due to paging responses
C10023 Number of wireless channel accesses due to call re-establishments
Number o number of wireless channel accesses due to IMSI
C10024
detachment
C10025 Number of wireless channel accesses due to other causes

Random Access Counters Explanation


C10001
Definition

Number of invalid random access requests


Description

C10001 represents number of invalid requests for channel. Initially MS


sends Channel request to BTS for random access. Then BTS sends
Channel required message to BSC in response of MS request. If TA

88 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - Random Access

exceeds cell range, BSC treats this access request as interference. At


this time, BSC discards invalid channel request and C10001 increments.
Measurement Point

Refer point A2 as shown in FIGURE 7.

FIGURE 7 - RANDOM ACCESS PROCESS

M S B TS B S C
C H L_R EQ
C H L_R Q D

A 1

A 2
C H L_A CT

CH L_ACT_AC K

A 3

IM M _ A S S _ C M D
IM M _ A S S
SABM
E S T _ IN D

A 4

C10002
Definition

Number of Mobile Originated Call (MOC) random access attempts


Description

C10002 represents number of random access requests due to Mobile


Originated Call (MOC). If TA does not exceed cell range, BSC treats
this random access request as valid mobile originated call and C10003
increments.
Measurement Point

Refer point A1 as shown in FIGURE 7.

C10003
Definition

Number of successful random access processes due to MOC attempts


Description

BSC allows MS to access the network due to MOC. Initially MS sends


CHL_REQ message to BTS to apply for channel. BSC sends CHL_ACT
command to BTS to activate the channel for MS. BTS in response
sends CHL_ACT_ACK message to BSC. After that, C10003 increments
and BSC sends IMM_ASS_CMD message to BTS and then to MS.
Measurement Point

Confidential and Proprietary Information of ZTE CORPORATION 89


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Refer point A3 in FIGURE 7.

C10004
Definition

Number of successful MOC random accesses


Description

C10004 represents number of successful random accesses, when BTS


assigns the channel to MS due to mobile originated call (MOC). After
successfully access, MS sends EST_IND message to BSC through BTS.
C10004 increments when BSC receives EST_IND message.
Measurement Point

Refer point A4 as shown in FIGURE 7.

C10005
Definition

Number of Mobile Terminated Call (MTC) random access attempts


Description

C10005 represents number of random access requests due to MTC. If


TA does not exceed cell range, BSC treats this random access request
as valid mobile Terminated call and C10003 increments.
Measurement Point

Refer point A1 as shown in FIGURE 7.

C10006
Definition

Number of successful random access processes due to MTC attempts


Description

BSC allows MS to access the network due to MTC. Initially MS sends


CHL_REQ message to BTS to apply for channel. BSC sends CHL_ACT
command to BTS to activate the channel for MS. BTS in response
sends CHL_ACT_ACK message to BSC. After that, C10003 increments
and BSC sends IMM_ASS_CMD message to BTS and then to MS.
Measurement Point

Refer point A3 as shown in FIGURE 7.

C10007
Definition

Number of successful MTC random accesses

90 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - Random Access

Description
C10007 represents number of successful random accesses, when BTS
assigns the channel to MS due to MTC. After successfully access, MS
sends EST_IND message to BSC through BTS. C10007 increments
when BSC receives EST_IND message.
Measurement Point

Refer point A4 as shown in FIGURE 7.

C10008
Definition

Number of random access attempts due to call re-establishment.


Description

C10008 represents number of random access requests due to call re-


establishment. Initially MS sends CHL_REQ message to BTS to apply
for channel. Then BTS sends CHL_RQD message to BSC in response of
MS request. C10003 increments, if TA does not exceed cell range and
cause of wireless access is call reestablishment.
Measurement Point

Refer point A1 as shown in FIGURE 7.

C10009
Definition

Number of successful random access processes due to call re-


establishment
Description

BSC allows MS to access the network due to MTC. Initially MS sends


CHL_REQ message to BTS to apply for channel. BSC sends CHL_ACT
command to BTS to activate the channel for MS. BTS in response
sends CHL_ACT_ACK message to BSC. After that, C10009 increments
and BSC sends IMM_ASS_CMD message to BTS and then to MS.
Measurement Point

Refer point A3 as shown in FIGURE 7.

C10010
Definition

Number of successful random accesses due to call re-establishment


Description

C10010 represents number of successful random accesses, when BTS


assigns the channel to MS due for call-reestablishment. After

Confidential and Proprietary Information of ZTE CORPORATION 91


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

successfully access, MS sends EST_IND message to BSC through BTS.


C10010 increments when BSC receives EST_IND message.
Measurement Point

Refer point A4 as shown in FIGURE 7.

C10011
Definition

Number of random access attempts due to emergency calls


Description

C10011 represents number of random access requests due to


emergency calls. Initially MS sends CHL_REQ message to BTS to apply
for channel. Then BTS sends CHL_RQD message to BSC in response of
MS request. If TA does not exceed cell range and cause of wireless
access is call reestablishment, C10011 increments.
Measurement Point

Refer point A1 as shown in FIGURE 7.

C10012
Definition

Number of successful random access processes due to emergency


calls
Description

BSC allows MS to access the network due to emergency calls. Initially


MS sends CHL_REQ message to BTS to apply for channel. BSC sends
CHL_ACT command to BTS to activate the channel for MS. BTS in
response sends CHL_ACT_ACK message to BSC. After that, C10012
increments and BSC sends IMM_ASS_CMD message to BTS and then
to MS.
Measurement Point

Refer point A3 as shown in FIGURE 7.

C10013
Definition

Number of successful random accesses due to emergency calls


Description

C10013 represents number of successful random accesses, when BTS


assigns the channel to MS due for emergency calls. After successfully
access, MS sends EST_IND message to BSC through BTS. C10013
increments when BSC receives EST_IND message.

92 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - Random Access

Measurement Point

Refer point A4 as shown in FIGURE 7.

C10014
Definition

Number of wireless access attempts due to location update request


Description

C10014 represents number of accesses to wireless channel requests


due to location update request. Initially MS sends CHL_REQ message
to BTS to apply for a wireless channel. Then BTS sends CHL_RQD
message to BSC as a response of MS request. If TA does not exceed
cell range and cause of random access is location update, C10014
increments.
Measurement Point

Refer point A1 as shown in FIGURE 7.

C10015
Definition

Number of successful random access processes due to location update


Description

BSC allows MS to access the network due to location update. Initially


MS sends CHL_REQ message to BTS to apply for channel. BSC sends
CHL_ACT command to BTS to activate the channel for MS. BTS in
response sends CHL_ACT_ACK message to BSC. After that, C10015
increments and BSC sends IMM_ASS_CMD message to BTS and then
to MS.
Measurement Point

Refer point A3 as shown in FIGURE 7.

C10016
Definition

Number of successful random accesses due to location update


Description

C10016 represents number of successful random accesses, when BTS


assigns the channel to MS due for location update. After successfully
access, MS sends EST_IND message to BSC through BTS. C10016
increments when BSC receives EST_IND message.
Measurement Point

Refer point A4 as shown in FIGURE 7.

Confidential and Proprietary Information of ZTE CORPORATION 93


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C10017
Definition

Number of random access attempts for other causes


Description

C10017 represents number of random access requests for causes other


than MOC, MTC, call re-establishment, LOC, emergency call or IMSI
detachment. Initially MS sends CHL_REQ message to BTS to apply for
a channel. Then BTS sends CHL_RQD message to BSC in response of
MS request. If TA does not exceed cell range and cause of random
access is other than the above mention causes C10017 increments.
Measurement Point

Refer point A1 as shown in FIGURE 7.

C10018
Definition

Number of successful random access processes for other causes


Description

BSC allows MS to access the network for other causes. Initially MS


sends CHL_REQ message to BTS to apply for channel. BSC sends
CHL_ACT command to BTS to activate the channel for MS. BTS in
response sends CHL_ACT_ACK message to BSC. After that, C10018
increments and BSC sends IMM_ASS_CMD message to BTS and then
to MS.
Measurement Point

Refer point A3 as shown in FIGURE 7.

C10019
Definition

Number of successful random accesses for other causes


Description

C10019 represents number of successful random accesses, when BTS


assigns the channel to MS for other causes. After successfully access,
MS sends EST_IND message to BSC through BTS. C10019 increments
when BSC receives EST_IND message.
Measurement Point

Refer point A4 as shown in FIGURE 7.

94 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 - Random Access

C10020
Definition

Number of wireless accesses due to is location update


Description

C10020 represents number of wireless accesses due to location update.


Counter C10020 increments when BSC receives EST_IND message and
access cause is location update in L3 message.
Measurement Point

Refer point A4 as shown in FIGURE 7.

C10021
Definition

Number of wireless channel accesses due to call origination


Description

C10021 represents number of wireless channel accesses due to call


origination. C10021 increments when BSC receives EST_IND message
and access cause is call origination in L3 message.
Measurement Point

Refer point A4 as shown in FIGURE 7.

C10022
Definition

Number of wireless channel accesses due to paging response


Description

C10022 represents number of wireless channel accesses due to paging


response. Counter C10022 increments when BSC receives EST_IND
message and access cause is paging response in L3 message.
Measurement Point

Refer point A4 as shown in FIGURE 7.

C10023
Definition

Number of wireless channel accesses due to call re-establishment


Description

C10023 represents number of wireless channel accesses due to call re-


establishment. Counter C10023 increments when BSC receives

Confidential and Proprietary Information of ZTE CORPORATION 95


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

EST_IND message and access cause is call re-establishment in L3


message.
Measurement Point

Refer point A4 as shown in FIGURE 7.

C10024
Definition

Number of wireless channel accesses due to IMSI detachment


Description

C10024 represents number of wireless channel accesses due to IMSI


detachment. Counter C10024 increments when BSC receives EST_IND
message and access cause is IMSI detachment in L3 message.
Measurement Point

Refer point A4 as shown in FIGURE 7.

C10025
Definition

Number of wireless channel accesses due to other causes


Description

C10025 represents number of number of wireless channel accesses


due to other causes. Counter C10025 increments when BSC receives
EST_IND message. Wireless accesses causes are not Mobile Originated
Call (MOC), Mobile Terminated Call (MTC), call re-establishment,
location update (LOC), emergency call or IMSI detachment in L3
message.
Measurement Point

Refer point A4 as show in FIGURE 7.

96 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5

SDCCH Measurement

This chapter covers the following topics:

SDCCH Counters

SDCCH Counters
SDCCH Counters provide statistics about:

SDCCH allocation

SDCCH seizure

SDCCH assignment

Related RF parameters can be adjusted by analyzing SDCCH counters.

FIGURE 8 - SDCCH ASSIGNMENT FLOW

MS BTS BSC
CHL_REQ
CHL_RQD

A1
CHL_ACT

CHL_ACT_ACK

A2

IMM_ASS_CMD
IMM_ASS
SABM
EST_IND

A3

Table 13 lists all the SDCCH counters.

Confidential and Proprietary Information of ZTE CORPORATION 97


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

TABLE 13 SDCCH COUNTERS

Counter No. Counter Definition


C10101 Number of SDCCH call attempts during assignment
C10102 Number of successful SDCCH call attempts during assignment
C10103 Number of unsuccessful SDCCH call attempts during assignment
C10104 Number of SDCCH call attempts during handover
C10105 Number of successful SDCCH call attempts during handover
C10106 Number of unsuccessful SDCCH call attempts during handover
C10107 Number of SDCCH allocation attempts during assignment
C10108 Number of successful SDCCH allocations during assignment
C10109 Number of unsuccessful SDCCH allocations during assignment
C10110 Number of SDCCH allocation attempts during handover
C10111 Number of successful SDCCH allocations during handover
C10112 Number of unsuccessful SDCCH allocations during handover
C10113 Number of SDCCH assignment attempts
C10114 Number of successful SDCCH assignments
C10115 Number of unsuccessful SDCCH assignments
C10116 Number of SDCCH handover attempts
C10117 Number of successful SDCCH handovers
C10118 Number of unsuccessful SDCCH handovers with return
C10119 Number of unsuccessful SDCCH handovers without return

SDCCH Counters Explanation


C10101
Definition

Number of SDCCH call attempts during assignment


Description

Number of SDCCH call attempts during assignment = Number of


successful SDCCH call attempts during assignment + Number of
unsuccessful SDCCH call attempts during assignment
Measurement Point

C10101 increments at the same time with the counters C10102 or


C10103.

98 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5 - SDCCH Measurement

C10102
Definition

Number of successful SDCCH call attempts during assignment


Description

C10102 represents number of successful requests for SDCCH during


assignment.
Initially MS sends CHL_REQ message to BSC through BTS and it
triggers SDCCH allocation attempts.
After receiving CHL_REQ message, BSC attempts to allocate a channel
for this request.
If SDCCH allocation succeeds, C10102 increments.
If return for application message shows that there is no SDDCH, BSC
puts SDCCH request on waiting.
If the waiting succeeds, counter C10102 increments.
Measurement Point

Point A1 in FIGURE 8

C10103
Definition

Number of unsuccessful SDCCH call attempts during assignment


Description

C10103 represents number of unsuccessful SDCCH requests during


assignment.
Initially MS sends CHL_REQ message to BSC through BTS and it
triggers SDCCH allocation attempts.
After receiving CHL_REQ message, BSC attempts to allocate a channel
for this request.
If SDCCH call attempt fails, C10103 increments.
If return for application message shows that there is no SDDCH, BSC
puts SDCCH request on waiting.
If the waiting fails, counter C10103 increments.
Measurement Point

C10103 increments when BSC receives the negative acknowledgment


in response to the ‘Channel Activation’ message.

C10104
Definition

Number of SDCCH call attempts during handover

Confidential and Proprietary Information of ZTE CORPORATION 99


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Description

Number of SDCCH call attempts during handover = Number of


successful SDCCH call attempts during handover + Number of
unsuccessful SDCCH call attempts during handover
Measurement Point

C10104 increments at the same time with the counters C10105 or


C10106.

C10105
Definition

Number of successful SDCCH call attempts during handover


Description
C10105 represents number of successful requests for SDCCH during
handover. SDCCH allocation attempts trigger due to RADIO_APPLY
message from other channel instances. After receiving RADIO_APPLY
message, BSC attempts to allocate a channel for this request.
If allocation of SDCCH succeed, C10105 increments.
If return for application message shows that there is no SDCCH BSC
put this application on waiting.
If waiting succeeds, C10105 increments.
If return for application message shows that transceiver is faulty, the
three counters remains change.
Measurement Point

Point A1 in FIGURE 8

C10106
Definition

Number of unsuccessful SDCCH call attempts during handover


Description

Counter C10106 represents number of unsuccessful SDCCH requests


during handover. SDCCH allocation attempts trigger due to
RADIO_APPLY message from other channel instances. After receiving
RADIO_APPLY message, BSC attempts to allocate a channel for this
request.
If SDCCH call attempt fails, C10106 increments.
If return for application message shows that there is no SDCCH,
BSC puts this application on queuing.
If waiting for SDCCH fail, C10106 increments
If return for application message shows that transceiver is faulty,
C10106 remains unchanged.

100 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5 - SDCCH Measurement

In other cases, C10106 increments.


Measurement Point

C10106 increments when BSC receives the negative acknowledgment


in response to the ‘Channel Activation’ message.

C10107
Definition

Number of SDCCH allocation attempts during assignment


Description

C10107 represents number of SDCCH allocations requests during


assignment.
Number of SDCCH allocation attempts during assignment = Number of
successful SDCCH allocations during assignment + Number of
unsuccessful SDCCH allocations during assignment
Measurement Point

C10107 increments at the same time with the counters C10108 or


C10109.

C10108
Definition

Number of successful SDCCH allocations during assignment


Description

C10108 represents number of successful allocations of SDCCH during


assignment. Initially BSC responds to SDCCH request when BSC sends
CHL_ACT message to BTS to activate SDCCH. After successful
allocation of SDCCH, counter C10108 get incremented.
Measurement Point

Point A2 in FIGURE 8

C10109
Definition

Number of unsuccessful SDCCH allocations during assignment


Description

C10109 represents number of SDCCH allocation failures during SDCCH


assignment. Initially BSC responds to SDCCH request message from
MS by seizing SDCCH successfully and BSC sends CHL_ACT message
to BTS to activate SDCCH.
Counter C10109 increments in the following conditions:
SDCCH activation fails

Confidential and Proprietary Information of ZTE CORPORATION 101


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

BSC receives incorrect SDCCH response message


Timer T9103 expires
BSC releases SDCCH normally or forcibly.
Measurement Point

C10109 increments when BSC receives the negative acknowledgment


in response to the ‘Channel Activation’ message.

C10110
Definition

Number of SDCCH allocation attempts during handover


Description

C10110 represents number of SDCCH allocations requests during


handover.
Number of SDCCH allocation attempts during handover = Number of
successful SDCCH allocations during handover + Number of
unsuccessful SDCCH allocations during handover
Measurement Point

C10110 increments at the same time with the counters C10111 or


C10112.

C10111
Definition

Number of SDCCH successful allocations during handover


Description

C10111 represents number of successful allocation of SDCCH during


handover. Initially BSC responds to SDCCH request by sending
CHL_ACT message to BTS to activate SDCCH. After successful
allocation of SDCCH, counter C10111 increments.
Measurement Point

C10111 increments when BSC correctly receives CHL_ACT_ACK


message from BTS during handover.

C10112
Definition

Number of SDCCH unsuccessful allocations during handover


Description

C10112 represents number of SDCCH allocation failures. Initially BSC


responds to SDCCH request message from MS by sending CHL_ACT
message to BTS to activate SDCCH.

102 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5 - SDCCH Measurement

C10109 increments in the following conditions:


SDCCH activation fails
BSC receives incorrect SDCCH response message
Timer T9103 expires,
BSC releases SDCCH normally or forcibly
Measurement Point

C10109 increments when BSC receives the negative acknowledgment


in response to the SDCCH ‘Channel Activation’ message.

C10113
Definition

Number of SDCCH assignment attempts


Description

Number of SDCCH assignment attempts = Number of successful


SDCCH assignments + Number of unsuccessful SDCCH assignments
Measurement Point

C10113 increments at the same time with the counters C10114 or


C10115.

C10114
Definition

Number of successful SDCCH assignments


Description

C10114 represents number of successful SDCCH assignments when


BSC sends IMM_ASS message to MS to use the allocated SDCCH
during assignment. If BSC successfully assigns SDCCH, counter
C10114 increments.
Measurement Point

C10114 increments when BSC receives correct EST_IND message or


assignment complete message.

C10115
Definition

Number of unsuccessful SDCCH assignments


Description

C10115 represents number of unsuccessful SDCCH assignments when


BSC sends IMM_ASS message to MS to use the allocated SDCCH

Confidential and Proprietary Information of ZTE CORPORATION 103


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

during assignment. If SDCCH assignment fails, counter C10115 and


counter C10114 increments at the same time.
Measurement Point

C10115 increments when BSC receives the negative acknowledgment


in response to the SDCCH ‘Assignment Command’ message.

C10116
Definition

Number of SDCCH handover attempts


Description

Number of SDCCH handover attempts = Number of successful SDCCH


handovers + Number of unsuccessful SDCCH handovers
For successful handover, counter C10116 and counter C10117
increments at the same time.
For unsuccessful handover, counter C10116 and counter C10118
increments at the same time.
For other handover failures, counter C10116and counter C10119
increments at the same time.
Measurement Point

C10116 increments when BSC receives ASS_COM (for intra-cell


handover) or HO_COM (for inter-cell handover) message

C10117
Definition

Number of successful SDCCH handovers


Description

C10117 represents number of successful SDCCH handovers. During


handover, after MS successfully accesses new channel, BSC receives
ASS_COM (for intra-cell handover) or HO_COM (for inter-cell handover)
message. If handover is successful, this counter increment at the same
time.
Measurement Point

C10117 increments when BSC receives ASS_COM (for intra-cell


handover) or HO_COM (for inter-cell handover) message

C10118
Definition

Number of unsuccessful SDCCH handovers with return


Description

104 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5 - SDCCH Measurement

Not Implemented

C10119
Definition

Number of unsuccessful SDCCH handovers without return


Description
Not Implemented

Confidential and Proprietary Information of ZTE CORPORATION 105


This page is intentionally blank

106 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6

TCH/F Measurement

This chapter covers the following topics:

TCH/F Measurement Counters.

TCH/F Counters
TCH/F measurement counters provide statistics for the following channels:

TCH/F allocation requests


TCH/F allocations
TCH/F assignment requests
TCH/F assignments
TCH/F handover requests
TCH/F handovers
Two types of Assignment flow:

Immediate Assignment
Common Assignment
Immediate Assignment: MS originates the assignment request, which BSC
has to fulfill.

Common Assignment: MSC originates the assignment command for the


MS.

FIGURE 9 and FIGURE 10 illustrates the two types of assignment flows.

Confidential and Proprietary Information of ZTE CORPORATION 107


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

FIGURE 9 - IMMEDIATE ASSIGNMENT FLOW

MS BTS BSC

CHL_REQ
CHL_RQD

A1

CHL_ACT

CHL_ACT_ACK

A2

IMM_ASS_CMD
IMM_ASS
SABM
EST_IND

A3

FIGURE 10 - COMMON ASSIGNMENT FLOW

MS BTS BSC MSC

ASS_CMD

B1
CHL_ACT
CHL_ACT_ACK

B2
ASS_CMD
ASS_CMD
SABM
UA EST_IND

B3
ASS_COM
ASS_COM

B4
ASS_COM

108 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 - TCH/F Measurement

There are two types of handover flows:

Internal Handover
External Handover
FIGURE 11 and FIGURE 12 illustrates the two types of assignment flows.

Internal Handover: Handover without the involvement of MSC.

External Handover: Handover with the involvement of MSC.

FIGURE 11 - INTERNAL HANDOVER (INTRA-BSC HANDOVER)

MS BTS BSC MSC

MEAS_REP
MEAS_RES

C1
CHL_ACT
CHL_ACT_ACK

C2
ASS_CMD
ASS_CMD
SABM
UA EST_IND
ASS_COM
ASS_COM

C3
HO_PREFORM

FIGURE 12 - EXTERNAL HANDOVER (INTRA-MSC HANDOVER)

MS BTS BSC MSC

HO_REQ

D1
CHL_ACT
CHL_ACT_ACK

D2
HO_REQ_ACK
HO_ACCESS
HO_DETECT
PHY_INFO
HO_DETECT
SABM
UA
HO_COM
HO_COM

D3
HO_COM

Confidential and Proprietary Information of ZTE CORPORATION 109


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Table 18 lists all the TCH/F measurement counters.

TABLE 18 TCHF MEASUREMENT COUNTERS

Counter No. Definition


C10301 Number of TCH/F call attempts for assignment (signaling)
C10302 Number of successful TCH/F call attempts for assignment (signaling)
C10303 Number of unsuccessful TCH/F call attempts for assignment (signaling)
C10304 Number of TCH/F call attempts for handover (signaling)
C10305 Number of successful TCH/F call attempts for handover (signaling)
C10306 Number of unsuccessful TCH/F call attempts for handover (signaling)
C10307 Number of BSC attempts to allocate TCH/F for assignment (signaling)
C10308 Number of successful allocation of TCH/F for assignment (signaling)
C10309 Number of unsuccessful TCH/F allocation for assignment (signaling)
C10310 Number of BSC attempts to allocate TCH/F in case of handover (signaling)
C10311 Number of successful allocation of TCH/F in case of handover (signaling)
C10312 Number of unsuccessful TCH/F allocation in case of handover (signaling)
C10313 Number of BSC attempts to assign TCH/F (signaling)
C10314 Number of successful assignment of TCH/F (signaling)
C10315 Number of unsuccessful TCH/F assignment (signaling)
C10316 Number of handover attempts for TCH/F (signaling).
C10317 Number of successful TCH/F handover (Signaling)
C10318 Number of unsuccessful TCH/F handover (Signaling).
Number of BSC does not receives ‘Handover Fail’ message on the TCH/F
C10319
(signaling)
C10320 Number of requests for TCH/F assignment (voice)
C10321 Number of successful request for TCH/F assignment (voice)
C10322 Number of unsuccessful request for TCH/F assignment (voice)
C10323 Number of requests for TCH/F handover (voice)
C10324 Number of successful request for TCH/F handover (voice)
C10325 Number of unsuccessful request for TCH/F handover failures (voice)
Number of BSC attempts to allocate TCH/F for assignment (voice version
C10326
1)
C10327 Number of successful allocation of TCH/F for assignment (voice version 1)
Number of unsuccessful allocation of TCH/F for assignment (voice
C10328
version1)
C10329 Number of BSC attempts to allocate TCH/F for handover (voice version 1)
C10330 Number of successful TCH/F allocation for handover (voice version 1)
C10331 Number of unsuccessful TCH/F allocation for handover (voice version1)
Number of BSC attempts to allocate TCH/F for assignment (voice version
C10332
2)

110 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 - TCH/F Measurement

C10333 Number of successful allocation of TCH/F for assignment (voice version 2)


C10334 Number of unsuccessful TCH/F allocation for assignment (voice version2)
C10335 Number of BSC attempts to allocate TCH/F for handover (voice version 2)
C10336 Number of successful allocation of TCH/F for handover (voice version 2)
C10337 Number of unsuccessful TCH/F allocation for handover (voice version2)
C10338 Number of BSC attempts to allocate TCH/F for assignment (voice version3)
C10339 Number of successful allocation of TCH/F for assignment (voice version 3)
C10340 Number of unsuccessful TCH/F allocation for assignment (voice version 3)
C10341 Number of BSC attempts to allocate TCH/F for handover (voice version 3)
C10342 Number of successful allocation of TCH/F for handover (voice version 3)
C10343 Number of unsuccessful TCH/F allocation for handover (voice version 3)
C10344 Number of BSC attempts to assign TCH/F (Voice)
C10345 Number of successful assignment of TCH/F (Voice)
C10346 Number of unsuccessful TCH/F assignment (voice)
C10347 Number of handover attempts for TCH/F (Voice).
C10348 Number of successful TCH/F handover (Voice)
C10349 Number of unsuccessful TCH/F handover (Voice).
Number of BSC does not receives ‘Handover Fail’ message on the TCH/F
C10350
(Voice)
C10351 Number of requests for TCH/F assignment (data)
C10352 Number of successful request for TCH/F assignment (data)
C10353 Number of unsuccessful request for TCH/F assignment (data)
C10354 Number of requests for TCH/F handover (data)
C10355 Number of successful request for TCH/F handover (data)
C10356 Number of unsuccessful request for TCH/F handover (data)
C10357 Number of BSC attempts to allocate TCH/F for assignment (data)
C10358 Number of successful allocation of TCH/F for assignment (data)
C10359 Number of unsuccessful TCH/F allocation for assignment (data)
C10360 Number of BSC attempts to allocate TCH/F for handover (data)
C10361 Number of successful allocation of TCH/F for handover (data)
C10362 Number of unsuccessful TCH/F allocation for handover (data)
C10363 Number of BSC attempts to assign TCH/F (data)
C10364 Number of successful assignment of TCH/F (data)
C10365 Number of unsuccessful TCH/F assignment (data)
C10366 Number of handover attempts for TCH/F (data).
C10367 Number of successful TCH/F handover (data)
C10368 Number of unsuccessful TCH/F handover (data).
Number of BSC does not receives ‘Handover Fail’ message on the TCH/F
C10369
(data)

Confidential and Proprietary Information of ZTE CORPORATION 111


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

TCHF Counters Explanation


C10301
Definition

Number of TCH/F call attempts for assignment (signaling)


Description
Number of TCH/F call attempts for assignment = Number of successful
TCH/F call attempts for assignment (signaling) + Number of
unsuccessful TCH/F call attempts for assignment (signaling)
Calculation Formula

C10301 = C10302 + C10303


Measurement Point
Counter ‘C10301’ increments at the same time with counters ‘C10302’
or ‘C10303’.

C10302
Definition

Number of successful TCH/F call attempts for assignment (signaling)


Description
Request for TCH/F assignment only becomes successful when BSC
successfully allocates the TCH/F. This counter keeps represents of
number of successful requests for TCH/F assignment as a signaling
channel.
Measurement Point

Counter ‘C10302’ increments when BSC successfully allocates the


TCH/F.

C10303
Definition

Number of unsuccessful TCH/F call attempts for assignment (signaling)

Description

Request for TCH/F assignment becomes unsuccessful when BSC


receives negative acknowledgement for the channel activation request.
This counter is only to keep record of number of unsuccessful requests
for TCH/F assignment as a signaling channel.

112 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 - TCH/F Measurement

Measurement Point

Counter ‘C10303’ increments when BSC receives the negative


acknowledgment in response to the ‘Channel Activation’ message.

C10304
Definition

Number of TCH/F call attempts for handover (signaling)


Description

Number of TCH/F call attempts for handover (signaling) = Number of


successful TCH/F call attempts for handover (signaling) + Number of
unsuccessful TCH/F call attempts for handover (signaling)
Calculation Formula

C10304 = C10305 + C10306


Measurement Point
Counter ‘C10304’ has the measurement point same like counter
‘C10305’ or counter ‘C10306’.

C10305
Definition

Number of successful TCH/F call attempts for handover (signaling)


Description
Request for TCH/F assignment becomes successful when BSC
successfully allocates the TCH/F. This counter is only to keep record of
successful number of requests for TCH/F handover as a signaling
channel.
Measurement Point

Counter ‘C10305’ increments when BSC successfully allocates the


TCH/F.

C10306
Definition

Number of unsuccessful TCH/F call attempts for handover (signaling)


Description
Request for TCH/F assignment becomes unsuccessful when BSC
receives negative acknowledgement for the channel activation request.
This counter is only to keep record of number of unsuccessful requests
for TCH/F handover as a signaling channel.

Confidential and Proprietary Information of ZTE CORPORATION 113


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Measurement Point
Counter ‘C10306’ increments when BSC receives negative
acknowledgment in response to the ‘Channel Activation’ message.

C10307
Definition

Number of BSC attempts to allocate TCH/F for assignment (signaling)


Description
Counter ‘C10307’ represents the number of BSC attempts to activate
TCH/F to assign it to the MS, for the signaling purpose.
Calculation Formula
Number of BSC attempts to allocate TCH/F for assignment (signaling)
= Number of successful allocation of TCH/F for assignment (signaling)
+ Number of unsuccessful TCH/F allocation for assignment (signaling).
(C10307)= C10308 + C10309
Measurement Point
Counter ‘C10307’ increments at the same time with counters ‘C10308’
or ‘C10309’.

C10308
Definition

Number of successful allocation of TCH/F for assignment (signaling)


Description
Counter ‘C10308’ represents the number of BSC successfully activates
the TCH/F to assign it to the MS as a signaling channel.
Measurement Point

Counter ‘C10308’ increments when BSC receives ‘Channel Activation


Acknowledgement’ message from BTS, in case of successful allocation
of the TCH/F.

C10309
Definition

Number of unsuccessful TCH/F allocation for assignment (signaling)


Description
Counter ‘C10309’ represents the number of unsuccessful attempt BSC
makes to activate TCH/F to assign it to the MS as a signaling channel.
Causes for the failure can be:
Timeout for timer T9103
Overload
Function (channel) not available

114 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 - TCH/F Measurement

Measurement Point

Counter ‘C10309’ increments when BSC receives negative


acknowledgment in response to the ‘Channel Activation’ message.

C10310
Definition

Number of BSC attempts to allocate TCH/F in case of handover


(signaling)
Description
Counter ‘C10310’ represents the number of BSC attempts to activate
TCH/F as a signaling channel in case of handover.
Calculation Formula

Number of BSC attempts to allocate TCH/F in case of handover


(signaling) = Number of successful allocation of TCH/F in case of
handover (signaling) + Number of TCH/F allocation failures in case of
handover (signaling)
C10310 = C10311 + C10312
Measurement Point
Counter ‘C10310’ increments at the same time with counters ‘C10311’
or ‘C10312’.

C10311
Definition

Number of successful allocation of TCH/F in case of handover (signaling)


Description
Counter ‘C10311’ represents the number of BSC successfully activates
the TCH/F as a signaling channel purpose when handovers for the MS.
Measurement Point

Counter ‘C10311’ increments when BSC receives ‘Channel Activation


Acknowledgment’ message from BTS (C2-FIGURE 11 and D2-FIGURE
12).

C10312
Definition

Number of TCH/F allocation failures in case of handover (signaling)


Description
Counter ‘C10312’ represents the number of BSC failures to activate the
TCH/F as a signaling channel when handovers for the MS.

Confidential and Proprietary Information of ZTE CORPORATION 115


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Measurement Point

Counter ‘C10312’ increments when BSC receives negative


acknowledgment in response to the ‘Channel Activation’ message.

C10313
Definition

Number of BSC attempts to assign TCH/F (signaling)


Description
Counter ‘C10313’ represents the number of BSC attempts to assign
TCH/F to the MS as a signaling channel.
Calculation Formula

Number of BSC attempts to assign TCH/F (signaling) = Number of


successful assignment of TCH/F (signaling) + Number of TCH/F
allocation failures (signaling)
C10313 = C10314 + C10315
Measurement Point
Counter ‘C10313’ increments at the same time with counters ‘C10314’
or ‘C10315’.

C10314
Definition

Number of successful assignment of TCH/F (signaling)


Description
Counter ‘C10314’ represents the number of BSC successfully assigns
the TCH/F as a signaling channel.
Measurement Point

Counter ‘C10314’ increments when BSC receives ‘Establish indication’


message from BTS.

C10315
Definition

Number of TCH/F assignment failures (signaling)


Description
Counter ‘C10315’ represents the number of BSC failures to assign
TCH/F as a signaling channel.
Measurement Point
Counter ‘C10315’ increments when BSC receives negative
acknowledgment in response to the ‘Assignment Command’ message.

116 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 - TCH/F Measurement

C10316
Definition

Number of handover attempts for TCH/F (signaling).


Description
Counter ‘C10316’ represents the number of BSC attempts to handover
the MS on new TCH/F as a signaling channel. Handover involves both
intra-cell and inter-cell handover.
Calculation Formula

Number of handover attempts for TCH/F (signaling) = Number of


successful TCH/F handover (signaling) + Number of TCH/F handover
failures (signaling).
C10316 = C10317 + C10318
Measurement Point

Counter ‘C10316’ has the measurement point same like counter


‘C10317’ or counter ‘C10318’.

C10317
Definition

Number of successful TCH/F handover (Signaling)


Description

Counter ‘C10317’ represents the number of BSC receives signaling


about handover success on the new TCH/F, whether it is inter-cell or
intra-cell handover.
Measurement Point
Counter ‘C10317” increments when BSC receives ‘Assignment
Complete’ (intra-cell handover) or ‘Handover Complete’ message
(inter-cell handover) on the new TCH/F. Refer to FIGURE 11-C3 and
FIGURE 12-D3.

C10318
Definition

Number of unsuccessful TCH/F handover (Signaling).


Description

Counter ‘C10318’ represents the number of BSC failures to receive


signaling about handover success on the new TCH/F, whether it is
inter-cell or intra-cell handover.
Measurement Point
Counter ‘C10318” increments when BSC receives ‘Handover Fail’
message (inter-cell handover) on old TCH/F.

Confidential and Proprietary Information of ZTE CORPORATION 117


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C10319
Definition

Number of BSC does not receives ‘Handover Fail’ message on the


TCH/F (signaling)
Description

Not Implemented
Measurement Point
Not Implemented

C10320
Definition

Number of requests for TCH/F assignment (voice)


Description
Number of requests for TCH/F assignment (voice) = Number of request
for TCH/F assignment successful (voice) + Number of request for
TCH/F assignment failures (voice)
Calculation Formula

C10320 = C10321 + C10322


Measurement Point
Counter ‘C10320’ increments at the same time with counters ‘C10321’
or ‘C10322’.

C10321
Definition

Number of request for TCH/F assignment successful (voice)


Description
Request for TCH/F assignment becomes successful when BSC
successfully allocates the TCH/F. This counter is only to keep record of
number of requests for TCH/F assignment as a voice channel.
Measurement Point

Counter ‘C10302’ increments when BSC successfully allocates the


TCH/F.

118 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 - TCH/F Measurement

C10322
Definition

Number of request for TCH/F assignment failures (voice)


Description

Request for TCH/F assignment becomes unsuccessful when BSC


receives negative acknowledgement for the channel activation request.
This counter is only to keep record of number of unsuccessful requests
for TCH/F assignment as a voice channel.
Measurement Point

Counter ‘C10303’ increments when BSC receives the negative


acknowledgment in response to the ‘Channel Activation’ message.

C10323
Definition

Number of requests for TCH/F handover (voice)


Description
Number of requests for TCH/F handover (voice) = Number of
successful request for TCH/F handover (voice) + Number of
unsuccessful request for TCH/F handover (voice)
Calculation Formula

C10323 = C10324 + C10325


Measurement Point
Counter ‘C10323’ increments at the same time with counters ‘C10324’
or ‘C10325’.

C10324
Definition

Number of request for TCH/F handover successful (voice)


Description
Request for TCH/F handover becomes successful when BSC
successfully allocates the TCH/F. This counter is only to keep record of
number of requests for TCH/F handover as a voice channel.
Measurement Point

Counter ‘C10324’ increments when BSC successfully allocates the


TCH/F.

Confidential and Proprietary Information of ZTE CORPORATION 119


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C10325
Definition

Number of request for TCH/F handover failures (voice)


Description

Request for TCH/F assignment becomes unsuccessful when BSC


receives negative acknowledgement for the channel activation request.
This counter is only to keep record of number of unsuccessful requests
for TCH/F handover as a voice channel.
Measurement Point

Counter ‘C10325’ increments when BSC receives the negative


acknowledgment in response to the ‘Channel Activation’ message.

C10326
Definition

Number of BSC attempts to allocate TCH/F for assignment (voice


version 1)
Description
Counter ‘C10310’ represents the number of BSC attempts to activate
TCH/F as a voice channel (version 1) for the assignment purpose.
Calculation Formula

Number of BSC attempts to allocate TCH/F for assignment (voice


version 1) = Number of successful allocation of TCH/F for assignment
(voice version 1) + Number of unsuccessful TCH/F allocation for
assignment (voice version 1)
C10326 = C10327 + C10328
Measurement Point
Counter ‘C10326’ increments at the same time with counters ‘C10327’
or ‘C10328’.

C10327
Definition

Number of successful allocation of TCH/F for assignment (voice version


1)
Description
Counter ‘C10327’ represents the number of BSC successfully activates
the TCH/F as a voice channel (version 1) for the assignment purpose.

120 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 - TCH/F Measurement

Measurement Point

Counter ‘C10327’ increments when BSC receives ‘Channel Activation


Acknowledgment’ message from BTS (A2-FIGURE 13 and B2-FIGURE
14).

C10328
Definition

Number of TCH/F allocation failures for assignment (voice version1)


Description
Counter ‘C10312’ represents the number of times BSC fails to activate
the TCH/F as a voice channel (version 1) for the assignment purpose.
Causes for the failure can be:
Timeout for timer T9103
Overload
Function (channel) not available
Measurement Point

Counter ‘C10328’ increments when BSC receives negative


acknowledgment in response to the ‘Channel Activation’ message.

C10329
Definition

Number of BSC attempts to allocate TCH/F for handover (voice version


1)
Description
Counter ‘C10329’ represents the number of times BSC attempts to
activate TCH/F as a voice channel (version 1) for the handover purpose.
Calculation Formula

Number of BSC attempts to allocate TCH/F for handover (voice version


1) = Number of successful allocation of TCH/F for handover (voice
version 1) + Number of unsuccessful TCH/F allocation for handover
(voice version 1)
C10329 = C10330 + C10331
Measurement Point
Counter ‘C10329’ increments at the same time with counters ‘C10330’
or ‘C10331’.

Confidential and Proprietary Information of ZTE CORPORATION 121


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C10330
Definition

Number of successful allocation of TCH/F for handover (voice version 1)


Description
Counter ‘C10330’ represents the number of times BSC successfully
activates the TCH/F as a voice channel (version 1) in case of handover.
Measurement Point

Counter ‘C10330’ increments when BSC receives ‘Channel Activation


Acknowledgment’ message from BTS (C2-FIGURE 9 and D2-FIGURE
10).

C10331
Definition

Number of TCH/F allocation fails for handover (voice version1)


Description
Counter ‘C10331’ represents the number of times BSC fails to activate
the TCH/F as a voice channel (version 1) for the handover purpose.
Causes for the failure can be:
Timeout for timer T9103
Overload
Function (channel) not available
Measurement Point

Counter ‘C10331’ increments when BSC receives negative


acknowledgment in response to the ‘Channel Activation’ message.

C10332
Definition

Number of BSC attempts to allocate TCH/F for assignment (voice


version 2)
Description
Counter ‘C10332’ represents the number of BSC attempts to activate
TCH/F as a voice channel (version 2) for the assignment purpose.
Calculation Formula

Number of BSC attempts to allocate TCH/F for assignment (voice


version 2) = Number of successful allocation of TCH/F for assignment
(voice version 2) + Number of unsuccessful TCH/F allocation for
assignment (voice version 2)
C10332 = C10333 + C10334

122 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 - TCH/F Measurement

Measurement Point
Counter ‘C10332’ increments at the same time with counters ‘C10333’
or‘C10334’.

C10333
Definition

Number of successful allocation of TCH/F for assignment (voice version


2)
Description
Counter ‘C10333’ represents the number of times BSC successfully
activates the TCH/F as a voice channel (version 2) for the assignment
purpose.
Measurement Point

Counter ‘C10333’ increments when BSC receives ‘Channel Activation


Acknowledgment’ message from BTS (A2-FIGURE 9 and B2-FIGURE
10).

C10334
Definition

Number of unsuccessful TCH/F allocation for assignment (voice


version2)
Description
Counter ‘C10334’ represents the number of times BSC fails to activate
the TCH/F as a voice channel (version 2) for the assignment purpose.
Causes for the failure are:
Timeout for timer T9103
Overload
Function (channel) not available
Measurement Point

Counter ‘C10334’ increments when BSC receives negative


acknowledgment in response to the ‘Channel Activation’ message.

C10335
Definition

Number of BSC attempts to allocate TCH/F for handover (voice version


2)
Description
Counter ‘C10335’ represents the number of BSC attempts to activate
TCH/F as a voice channel (version 2) for the handover purpose.

Confidential and Proprietary Information of ZTE CORPORATION 123


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Calculation Formula

Number of BSC attempts to allocate TCH/F for handover (voice version


2) = Number of successful allocation of TCH/F for handover (voice
version 1) + Number of unsuccessful TCH/F allocation for handover
(voice version 1)
C10335 = C10336 + C10337
Measurement Point
Counter ‘C10335’ increments at the same time with counters ‘C10336’
or ‘C10337’.

C10336
Definition

Number of successful allocation of TCH/F for handover (voice version 2)


Description
Counter ‘C10330’ represents the number of times BSC successfully
activates the TCH/F as a voice channel (version 1) in case of handover.
Measurement Point

Counter ‘C10336’ increments when BSC receives ‘Channel Activation


Acknowledgment’ message from BTS (C2-FIGURE 9 and D2-FIGURE
10).

C10337
Definition

Number of unsuccessful TCH/F allocation for handover (voice version2)


Description
Counter ‘C10337’ represents the number times BSC fails to activate
the TCH/F as a voice channel (version 2) for the handover purpose.
Causes for the failure are:
Timeout for timer T9103
Overload
Function (channel) not available
Measurement Point

Counter ‘C10337’ increments when BSC receives negative


acknowledgment in response to the ‘Channel Activation’ message.

C10338
Definition

Number of BSC attempts to allocate TCH/F for assignment (voice


version 3)

124 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 - TCH/F Measurement

Description
Counter ‘C10339’ represents the number of BSC attempts to activate
TCH/F as a voice channel (version 3) for the assignment purpose.
Calculation Formula

Number of BSC attempts to allocate TCH/F for assignment (voice


version 3) = Number of successful allocation of TCH/F for assignment
(voice version 3) + Number of unsuccessful TCH/F allocation for
assignment (voice version 3)
C10338 = C10339 + C10330
Measurement Point
Counter ‘C10338’ increments at the same time with counters ‘C10339’
or ‘C10330’.

C10339
Definition

Number of successful allocation of TCH/F for assignment (voice version


3)
Description
Counter ‘C10339’ represents the number of times BSC successfully
activates the TCH/F as a voice channel (version 2) for the assignment
purpose.
Measurement Point

Counter ‘C10339’ increments when BSC receives ‘Channel Activation


Acknowledgment’ message from BTS (A2-FIGURE 9 and B2-FIGURE
10).

C10340
Definition

Number of TCH/F allocation failures for assignment (voice version3)


Description
Counter ‘C10340’ represents the number of times BSC fails to activate
the TCH/F as a voice channel (version 2) for the assignment purpose.
Causes for the failure can be:
Timeout for timer T9103
Overload
Function (channel) not available
Measurement Point

Counter ‘C10340’ increments when BSC receives negative


acknowledgment in response to the ‘Channel Activation’ message.

Confidential and Proprietary Information of ZTE CORPORATION 125


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C10341
Definition

Number of BSC attempts to allocate TCH/F for handover (voice version


3)
Description
Counter ‘C10341’ represents the number of BSC attempts to activate
TCH/F as a voice channel (version 3) for the handover purpose.
Calculation Formula

Number of BSC attempts to allocate TCH/F for handover (voice version


3) = Number of successful allocation of TCH/F for handover (voice
version 3) + Number of unsuccessful TCH/F allocation failures for
handover (voice version 3)
C10341 = C10342 + C10343
Measurement Point
Counter ‘C10341’ increments at the same time with counters ‘C10342’
or ‘C10343’.

C10342
Definition

Number of successful allocation of TCH/F for handover (voice version 3)


Description
Counter ‘C10342’ represents the number of times BSC successfully
activates the TCH/F as a voice channel (version 3) in case of handover.
Measurement Point

Counter ‘C10342’ increments when BSC receives ‘Channel Activation


Acknowledgment’ message from BTS (C2-FIGURE 9 and D2-FIGURE
10).

C10343
Definition

Number of unsuccessful TCH/F allocation for handover (voice version 3)


Description
Counter ‘C10343’ represents the number of times BSC fails to activate
the TCH/F as a voice channel (version 3) for the handover purpose.
Causes for the failure are:
Timeout for timer T9103
Overload
Function (channel) not available

126 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 - TCH/F Measurement

Measurement Point

Counter ‘C10343’ increments when BSC receives negative


acknowledgment in response to the ‘Channel Activation’ message.

C10344
Definition

Number of BSC attempts to assign TCH/F (Voice)


Description
Counter ‘C10344’ represents the number of BSC attempts to assign
TCH/F to the MS in order to carry the user speech.
Calculation Formula

Number of BSC attempts to assign TCH/F (Voice) = Number of


successful assignment of TCH/F (Voice) + Number of TCH/F allocation
failures (Voice)
C10344 = C10345 + C10346
Measurement Point
Counter ‘C10344’ increments at the same time with counters ‘C10345’
or ‘C10346’.

C10345
Definition

Number of successful assignment of TCH/F (Voice)


Description
Counter ‘C10345’ represents the number of times BSC successfully
assigns TCH/F to the MS in order to carry the user speech.
Measurement Point

Counter ‘C10345’ increments when BSC receives ‘Establish indication’


message from BTS (A3-FIGURE 9).

C10346
Definition

Number of TCH/F assignment failures (voice)


Description
Counter ‘C10346’ represents the number of times BSC fails to assign
TCH/F to the MS in order to carry the user speech.
Measurement Point
Counter ‘C10346’ increments when BSC receives negative
acknowledgment in response to the ‘Assignment Command’ message.

Confidential and Proprietary Information of ZTE CORPORATION 127


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C10347
Definition

Number of handover attempts for TCH/F (Voice).


Description
Counter ‘C10347’ represents the number of BSC attempts to handover
the MS on new TCH/F voice channel, in case of both intra-cell and
inter-cell handover.
Calculation Formula

Number of handover attempts for TCH/F (Voice) = Number of


successful TCH/F handover (Voice) + Number of TCH/F handover
failures (Voice).
C10347 = C10348 + C10349
Measurement Point

Counter ‘C10347’ has the measurement point same like counter


‘C10348’ or counter ‘C10349’.

C10348
Definition

Number of successful TCH/F handover (Voice)


Description

Counter ‘C10348’ represents the number of times BSC receives


signaling about handover success on the new TCH/F voice channel.
Handover includes both inter-cell and intra-cell handover.
Measurement Point
Counter ‘C10348” increments when BSC receives ‘Assignment
Complete’ (intra-cell handover) or ‘Handover Complete’ message
(inter-cell handover) on the new TCH/F (Voice). Refer to FIGURE 11-C3
and FIGURE 12-D3.

C10349
Definition

Number of unsuccessful TCH/F handover (Voice).


Description

Counter ‘C10349’ represents the number of times BSC fails to receive


signaling about handover success on the new TCH/F voice channel.
Handover includes both inter-cell and intra-cell handover.
Measurement Point
Counter ‘C10349” increments when BSC receives ‘Handover Fail’
message (inter-cell handover) on old TCH/F.

128 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 - TCH/F Measurement

C10349
Definition

Number of BSC receives ‘Handover Fail’ message on the TCH/F (Voice)


Description

Not Implemented
Measurement Point
Not Implemented

C10350
Definition

Number of BSC does not receives ‘Handover Fail’ message on the


TCH/F (Voice)
Description

Not Implemented
Measurement Point
Not Implemented

C10351
Definition

Number of requests for TCH/F assignment (data)


Description
Number of requests for TCH/F assignment (data) = Number of
successful request for TCH/F assignment (data) + Number of
unsuccessful request for TCH/F assignment (data)
Calculation Formula

C10351 = C10352 + C10353


Measurement Point
Counter ‘C10351’ increments at the same time with counters ‘C10352’
or ‘C10353’.

C10352
Definition

Number of requests for TCH/F assignment successful (data)


Description
Request for TCH/F assignment becomes successful when BSC
successfully allocates the TCH/F. This counter is only to keep record of
number of requests for TCH/F assignment as a data channel.

Confidential and Proprietary Information of ZTE CORPORATION 129


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Measurement Point

Counter ‘C10352’ increments when BSC successfully allocates the


TCH/F.

C10353
Definition

Number of request for TCH/F assignment failures (data)


Description

Request for TCH/F assignment becomes unsuccessful when BSC


receives negative acknowledgement for the channel activation request.
This counter is only to keep record of number of unsuccessful requests
for TCH/F assignment as a data channel.
Measurement Point

Counter ‘C10353’ increments when BSC receives the negative


acknowledgment in response to the ‘Channel Activation’ message.

C10354
Definition

Number of requests for TCH/F handover (data)


Description
Number of requests for TCH/F handover (data) = Number of successful
request for TCH/F handover (data) + Number of unsuccessful request
for TCH/F handover (data)
Calculation Formula

C10354 = C10355 + C10356


Measurement Point
Counter ‘C10354’ increments at the same time with counters ‘C10355’
or ‘C10356’.

C10355
Definition

Number of request for TCH/F handover successful (data)


Description
Request for TCH/F handover becomes successful when BSC
successfully allocates the TCH/F. This counter is only to keep record of
number of requests for TCH/F handover as a data channel.
Measurement Point

Counter ‘C10355’ increments when BSC successfully allocates the


TCH/F.

130 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 - TCH/F Measurement

C10356
Definition

Number of request for TCH/F handover failures (data)


Description

Request for TCH/F assignment becomes unsuccessful when BSC


receives negative acknowledgement for the channel activation request.
This counter is only to keep record of number of unsuccessful requests
for TCH/F handover as a data channel.
Measurement Point

Counter ‘C10356’ increments when BSC receives the negative


acknowledgment in response to the ‘Channel Activation’ message.

C10357
Definition

Number of BSC attempts to allocate TCH/F for assignment (data)


Description
Counter ‘C10357’ represents the number of BSC attempts to activate
TCH/F as a data channel for the assignment purpose.
Calculation Formula

Number of BSC attempts to allocate TCH/F for assignment (data) =


Number of successful allocation of TCH/F for assignment (data) +
Number of unsuccessful TCH/F allocation for assignment (data)
C10357 = C10358 + C10359
Measurement Point
Counter ‘C10357’ increments at the same time with counters ‘C10358’
or ‘C10359’.

C10358
Definition

Number of successful allocation of TCH/F for assignment (data)


Description
Counter ‘C10358’ represents the number of times BSC successfully
activates the TCH/F as a voice channel (data) for the assignment
purpose.
Measurement Point

Counter ‘C10358’ increments when BSC receives ‘Channel Activation


Acknowledgment’ message from BTS (A2-FIGURE 11 and B2-FIGURE
12).

Confidential and Proprietary Information of ZTE CORPORATION 131


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C10359
Definition

Number of unsuccessful TCH/F allocation for assignment (data)


Description
Counter ‘C10359’ represents the number of times BSC fails to activate
the TCH/F as a data channel for the assignment purpose. Causes for
the failure are:
Timeout for timer T9103
Overload
Function (channel) not available
Measurement Point

Counter ‘C10359’ increments when BSC receives negative


acknowledgment in response to the ‘Channel Activation’ message.

C10360
Definition

Number of BSC attempts to allocate TCH/F for handover (data)


Description
Counter ‘C10360’ represents the number of BSC attempts to activate
TCH/F as a data channel for the handover purpose.
Calculation Formula

Number of BSC attempts to allocate TCH/F for handover (data) =


Number of successful allocation of TCH/F for handover (data) +
Number of unsuccessful TCH/F allocation for handover (voice version 3)
C10360 = C10361 + C10362
Measurement Point
Counter ‘C10360’ increments at the same time with counters ‘C10361’
or ‘C10362’.

C10361
Definition

Number of successful allocation of TCH/F for handover (data)


Description
Counter ‘C10361’ represents the number of BSC successfully activates
the TCH/F as a data channel in case of handover.
Measurement Point

Counter ‘C10361’ increments when BSC receives ‘Channel Activation


Acknowledgment’ message from BTS (C2-FIGURE 9 and D2-FIGURE
10).

132 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 - TCH/F Measurement

C10362
Definition

Number of unsuccessful TCH/F allocation for handover (data)


Description
Counter ‘C10362’ represents the number of times BSC fails to activate
the TCH/F as a data channel for the handover purpose. Causes for the
failure are:
Timeout for timer T9103
Overload
Function (channel) not available
Measurement Point

Counter ‘C10362’ increments when BSC receives negative


acknowledgment in response to the ‘Channel Activation’ message.

C10363
Definition

Number of BSC attempts to assign TCH/F (data)


Description
Counter ‘C10363’ represents the number of BSC attempts to assign
TCH/F to the MS in order to carry the user data.
Calculation Formula

Number of BSC attempts to assign TCH/F (data) = Number of


successful assignment of TCH/F (data) + Number of unsuccessful
TCH/F allocation failures (data)
C10363 = C10364 + C10365
Measurement Point
Counter ‘C10363’ increments at the same time with counters ‘C10364’
or ‘C10365’.

C10364
Definition

Number of successful assignment of TCH/F (data)


Description
Counter ‘C10364’ represents the number of times BSC successfully
assigns TCH/F to the MS in order to carry the user data.
Measurement Point

Counter ‘C10364’ increments when BSC receives ‘Establish indication’


message from BTS (A3-FIGURE 9).

Confidential and Proprietary Information of ZTE CORPORATION 133


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C10365
Definition

Number of unsuccessful TCH/F assignment (data)


Description
Counter ‘C10365’ represents the number of times BSC fails to assign
TCH/F to the MS in order to carry the user data.
Measurement Point
Counter ‘C10365’ increments when BSC receives negative
acknowledgment in response to the ‘Assignment Command’ message.

C10366
Definition

Number of handover attempts for TCH/F (data).


Description
Counter ‘C10366’ represents the number of BSC attempts to handover
the MS on new TCH/F data channel. Handover involves both intra-cell
and inter-cell handover.
Calculation Formula

Number of handover attempts for TCH/F (data) = Number of


successful of TCH/F handover (data) + Number of unsuccessful TCH/F
handover (data).
C10366 = C10367 + C10368
Measurement Point

Counter ‘C10366’ has the measurement point same like counter


‘C10367’ or counter ‘C10368’.

C10367
Definition

Number of successful TCH/F handover (data)


Description

Counter ‘C10367’ represents the number of times BSC receives


signaling about handover success on the new TCH/F data channel.
Handover involves both intra-cell and inter-cell handover.
Measurement Point
Counter ‘C10367” increments when BSC receives ‘Assignment
Complete’ (intra-cell handover) or ‘Handover Complete’ message
(inter-cell handover) on the new TCH/F data channel. Refer to FIGURE
11-C3 and FIGURE 12-D3.

134 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 - TCH/F Measurement

C10368
Definition

Number of unsuccessful TCH/F handover (data).


Description

Counter ‘C10368’ represents the number of times BSC fails to receive


signaling about handover success on the new TCH/F data channel.
Handover involves both intra-cell and inter-cell handover.
Measurement Point
Counter ‘C10368” increments when BSC receives ‘Handover Fail’
message (inter-cell handover) on old TCH/F.

C10369
Definition

Number of BSC does not receives ‘Handover Fail’ message on the


TCH/F (data)
Description

Not Implemented

Confidential and Proprietary Information of ZTE CORPORATION 135


This Page is intentionally blank

136 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7

Service Access Point Identifier


3

This chapter covers the following topics:

SAPI 3 Measurement

SAPI 3 Counters

SAPI 3 Introduction
The SAPI is a 6-bit field in LAPDm and defines the type of user to which a
message is addressed. Possible values of SAPI on Air-interface is SAPI=3
and SAPI=0. In this chapter SAPI 3 indicates SAPI=3.

This chapter only discusses the SAPI value equals to three (SAPI=3). SAPI
value equals to three (SAPI=3) is used for Supplementary Services (SS)
and Short Messages Services (SMS) on Air-interface.

If MS sends Short Message (SM), means MS originated SM (MO-SM).


Similarly if MS receives Short Message (SM), means MS terminated SM
(MT-SM). On the air interface SACCH/F, SACCH/H, SDCCH, FACCH/F and
FACCH/H transport short message. Present system implements counters
for SACH/F, SACH/H and SDDCH.

Confidential and Proprietary Information of ZTE CORPORATION 137


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

SAPI 3 Counters
FIGURE 13 illustrates measurement points for SAPI 3 measurement
counters.

FIGURE 13 - SAPI 3 COUNTERS MEASUREMENT POINTS

BTS BSC MSC

EST_IND(SAPI=3)

A1

DTAP_IND(SAPI=3)

A2
EST_REQ(SAPI=3)

EST_CONF(SAPI=3)

A3

DTAP_IND(SAPI=3)

A4
DATA_IND(SAPI=3)

A5

Table 14 lists performance counters in SAPI 3 measurement.

TABLE 14 SAPI 3 COUNTERS

Counter No. Counter Definition


C10201 Number of SAPI 3 link establishments on SACCH/F (MO-SM)
C10202 Number of SAPI 3 link establishments on SACCH/H (MO-SM)
C10203 Number of SAPI 3 link establishments on SDCCH (MO-SM)
C10204 Number of SAPI 3 link establishments on FACCH/F (MO-SM)
C10205 Number of SAPI 3 link establishments on FACCH/H (MO-SM)
C10206 Number of SAPI 3 link establishment requests on SACCH/F (MT-SM)
C10207 Number of SAPI 3 link establishment requests on SACCH/H (MT-SM)
C10208 Number of SAPI 3 link establishment requests on SDCCH (MT-SM)
C10209 Number of SAPI 3 link establishment requests on FACCH/F (MT-SM)
C10210 Number of SAPI 3 link establishment requests on FACCH/H (MT-SM)

138 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - Service Access Point Identifier 3

Counter No. Counter Definition


C10211 Number of successful SAPI 3 link establishments on SACCH/F (MT-SM)
C10212 Number of successful SAPI 3 link establishments on SACCH/H (MT-SM)
C10213 Number of successful SAPI 3 link establishments on SDCCH (MT-SM)
C10214 Number of successful SAPI 3 link establishments on FACCH/F (MT-SM)
C10215 Number of successful SAPI 3 link establishments on FACCH/H (MT-SM)
Number of DTAP messages on SDCCH uplink for point-to-point short
C10216
messages
Number of DTAP messages on SDCCH downlink for point-to-point short
C10217
messages
Number of DTAP messages on FACCH/F uplink for point-to-point short
C10218
messages
Number of DTAP messages on FACCH/F downlink for point-to-point short
C10219
messages
Number of DTAP messages on FACCH/H uplink for point-to-point short
C10220
messages
Number of DTAP messages on FACCH/H downlink for point-to-point short
C10221
messages
Number of DTAP messages on SACCH/F uplink for point-to-point short
C10222
messages
Number of DTAP messages on SACCH/F downlink for point-to-point short
C10223
messages
Number of DTAP messages on SACCH/H uplink for point-to-point short
C10224
messages
Number of DTAP messages on SACCH/H downlink for point-to-point short
C10225
messages

SAPI 3 Counters Explanation


C10201
Definition

Number of SAPI 3 link establishments on SACCH/F (MO-SM)


Description

C10201 represents number of link establishments for mobile-originated


short messages (MO-SM) through SACCH/F channel. BTS initially sends
EST_IND message to BSC. C10201 increments after BSC receive
EST_IND message with SAPI=3.
Measurement Point
Refer point A1 in FIGURE 13.

C10202
Definition

Confidential and Proprietary Information of ZTE CORPORATION 139


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Number of SAPI 3 link establishments on SACCH/H. (MO-SM)


Description

C10202 represents number of link establishment for mobile-originated


short messages (MO-SM) through SACCH/H channel. BTS initially
sends EST_IND message to BSC. C10202 increments after BSC
receives EST_IND message with SAPI=3.
Measurement Point

Refer point A1 in FIGURE 13.

C10203
Definition

Number of SAPI 3 link establishment on SDCCH. (MO-SM)


Description

C10203 represents number of link establishment for mobile-originated


short messages (MO-SM) through SDCCH. BTS initially sends EST_IND
message to BSC. C10203 increments after BSC receives EST_IND
message with SAPI=3.
Measurement Point

Refer point A1 in FIGURE 13.

C10204
Definition

Number of SAPI 3 link establishment on FACCH/F. (MO-SM)


Counter C10204 is not in the system at present.

C10205
Definition

Number of SAPI 3 link establishment on FACCH/H (MO-SM)


Counter C10205 is not in system at present.

C10206
Definition

Number of SAPI 3 link establishment requests on SACCH/F. (MT-SM)


Description

C10206 represents number of link establishment requests for mobile-


terminated short messages (MO-SM) through SACCH/F channel.
Initially MSC sends DTAP_IND message with SAPI=3 and BSC receives
this message. If there is no link establishment for the short message

140 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - Service Access Point Identifier 3

between BSC and MS, BSC initiates link establishment flow and then
C10206 increments.
Measurement Point

Refer point A2 in FIGURE 13.

C10207
Definition

Number of SAPI 3 link establishment requests on SACCH/H (MT-SM)


Description

C10207 represents number of link establishment requests for mobile-


terminated short messages (MO-SM) through SACCH/H channel.
Initially MSC sends DTAP_IND message and BSC receives this message
with SAPI=3. If there is no link establishment for short message
between BSC and MS, BSC initiates link establishment flow and then
C10207 increments.
Measurement Point

Refer point A2 in FIGURE 13.

C10208
Definition

Number of SAPI 3 link establishment requests on SDCCH (MT-SM)


Description

C10209 represents number of link establishment requests for mobile-


terminated short messages (MT-SM) through SDCCH. Initially MSC
sends DTAP_IND message and BSC receives this message. If no link
establishes for the short message between BSC and MS, the BSC
initiates the link establishment flow and then C10208 increments.
Measurement Point

Refer point A2 in FIGURE 13.

C10209
Definition

Number of SAPI 3 link establishment requests on FACCH/F (MT-SM)


Description
Counter C10209 is not in the system at present.

C10210
Definition

Number of SAPI 3 link establishment requests on FACCH/H (MT-SM)

Confidential and Proprietary Information of ZTE CORPORATION 141


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Description
Counter C10210 is not in the system at present.

C10211
Definition

Number of successful SAPI 3 link establishments on SACCH/F (MT-SM)


Description

C10211 represents number of successful link establishments for


mobile-terminated short messages (MT-SH) through SACCH/F channel.
Initially BTS increments short message link establishment flow and
sends link establishment confirmation message EST_CONF to BSC.
This indicates successful establishment of short message link, C10211
increments at this point.
Measurement Point

Refer point A3 in FIGURE 13.

C10212
Definition

Number of successful SAPI 3 link establishments on SACCH/H channel


(MT-SM)
Description

C10212 represents number of successful link establishments for


mobile-terminated short messages (MT-SM) through SACCH/H channel.
Initially BTS increments short message link establishment flow and
sends link establishment confirmation message EST_CONF to BSC. This
process indicates successful establishment of short message link,
C10212 increments at this point.
Measurement Point

Refer point A3 in FIGURE 13.

C10213
Definition

Number of successful SAPI 3 link establishments on SDCCH (MT-SM)


Description

C10213 represents number of successful link establishments for


mobile-terminated short messages (MT-SM) through SDCCH. Initially
BTS increments short message link establishment flow and sends link
establishment confirmation message EST_CONF to BSC. This process
indicates successful establishment of short message link, C10213
increments at this point.

142 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - Service Access Point Identifier 3

Measurement Point

Refer point A3 in FIGURE 13.

C10214
Definition

Number of successful SAPI 3 link establishments on FACCH/F (MT-SM)


Description
Counter C10214 is not in the system at present.

C10215
Definition

Number of successful SAPI 3 link establishments on FACCH/H (MT-SM)


Description
Counter C10215 is not in the system at present.

C10216
Definition

Number of DTAP messages on SDCCH uplink for point-to-point short


messages
Description

C10216 represents number of short messages in DTAP packets sent


from MS through SDCCH to network side.
Measurement Point

Refer A4 in FIGURE 13.

C10217
Definition

Number of DTAP messages on SDCCH downlink for point-to-point short


messages
Description

C10217 represents number of short messages in DTAP packets sent on


SDCCH from network side to MS.
Measurement Point

Refer point A5 in FIGURE 13.

Confidential and Proprietary Information of ZTE CORPORATION 143


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C10218
Definition

Number of DTAP messages on FACCH/F uplink for point-to-point short


messages.
Description

Counter C10218 is not in the system at present.

C10219
Definition

Number of DTAP messages on FACCH/F downlink for point-to-point


short messages
Counter C10219 is not in the system at present.

C10220
Definition

Number of DTAP messages on FACCH/H uplink for point-to-point short


messages
Counter C10220 is not in the system at present.

C10221
Definition

Number of DTAP messages on FACCH/H downlink for point-to-point


short messages
Counter C10221 is not in system at present

C10222
Definition

Number of DTAP messages on SACCH/F uplink for point-to-point short


messages.
Description

C10222 represents number of short messages in DTAP packets sent on


SACCH/F from MS to network side.
Measurement Point

Refer point A4 in FIGURE 13.

144 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 7 - Service Access Point Identifier 3

C10223
Definition

Number of DTAP messages on SACCH/F downlink for point-to-point


short messages
Description

C10223 represents number of short messages in DTAP packets sent on


SACCH/F from network side to MS.
Measurement Point

Refer point A5 in FIGURE 13.

C10224
Definition

Number of DTAP messages on SACCH/H uplink for point-to-point short


messages
Description

C10224 represents number of short message in DTAP packets sent on


SACCH/H from MS to network side.
Measurement Point

Refer point A4 in FIGURE 13.

C10225
Definition

Number of DTAP messages on SACCH/H downlink for point-to-point


short messages
Description

10225 represents number of short messages in DTAP packets sent on


SACCH/H from network side to MS.
Measurement Point

Refer point A5 in FIGURE 13.

Confidential and Proprietary Information of ZTE CORPORATION 145


This page is intentionally blank.

146 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 8

Radio Management Module


Measurement

This chapter covers the following topics:

RMM Assignment Measurement


RMM Queue Measurement

RMM Assignment Measurement


RR manages radio channels and resources. Radio resource consists of TCH,
RR and LAPD signaling. RMM Assignment Measurement provides the
statistics of radio channel assignment in RMM. If RMM can not apply radio
channel first time, it attempts multiple times. The counters in RMM
Assignment records problems from the perspective of a call.

RMM Assignment Counters


Table 15 lists all the RMM Assignment Counters.

TABLE 15 RMM ASSIGNMENT COUNTERS

Counter No. Counter Definition


C10501 Number of general assignment executions for voice channel
C10502 Number of assignments for forced release attempts for voice.
Number of assignment executions for voice channel due to forced
C10503
release.
C10504 Number of assignments for queuing attempts for voice channel
C10505 Number of assignments for execution for voice channel due to queuing
C10506 Total duration of successful assignment for queuing for voice channel
C10507 Number of successful assignments of queues for voice channel
C10508 Number of assignments for directed retry attempts for voice channel

Confidential and Proprietary Information of ZTE CORPORATION 147


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Counter No. Counter Definition


Number of assignments for execution for voice channel due to directed
C10509
retry
C10510 Number of general assignments for execution for data
C10511 Number of assignments for forced release attempts for data.
C10512 Number of assignment executions for data due to forced release.
C10513 Number of assignments for queuing attempts for data.
C10514 Number of assignments for execution for data due to queuing
C10515 Total duration of successful assignments for queuing for data
C10516 Number of successful assignments of queues for data
C10517 Number of assignments for directed retry attempts for data.
C10518 Number of assignment executions for data due to directed retry.

RMM Assignment Counters Explanation


C10501
Definition

Number of general assignment executions for voice channel.


Description

Initially BSC receives RADIO_APPLY message during channel


assignment flow. Then BSC attempts to assign a voice channel.
C10501 increments for successful voice channel assignment.
Measurement Point
C10501 increments when BSC assigns a voice channel successfully.

C10502
Definition
Number of forced release attempts for voice channel assignments
Description
Initially BSC receives RADIO_APPLY message during channel
assignment flow. If BSC fails to assign a voice channel due to lack of
radio resource, BSC attempts for forced release.
Measurement Point
C10502 increments when BSC attempts to release voice channel
forcibly.

C10503
Definition

Number of voice channel assignment executions due to forced release.

148 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 8 - Radio Management Module Measurement

Description

Initially BSC receives RADIO_APPLY message during channel


assignment flow. If BSC fails to assign a voice channel due to lack of
radio resource, it performs force release. Force release is successful
within fixed time and BSC acquires the voice channel for MS.
Measurement Point

C10503 increments after BSC executes force release assignment and


acquires voice channel.

C10504
Definition

Number of queuing attempts for voice channel assignments.


Description
Initially BSC receives RADIO_APPLY message during channel
assignment flow. If BSC fails to assign a voice channel and the system
does not allow forced release, BSC attempts for queuing.
Measurement Point

C10504 increments when BSC fails to assign voice channel and BSC
attempts to execute queuing operations.

C10505
Definition

Number of voice channel assignment executions due to queuing


Description

Initially BSC receives RADIO_APPLY message during channel


assignment flow. If BSC fails to assign a voice channel and the system
does not allow force release, BSC executes queuing. Queuing is
successful within the fixed time.
Measurement Point

C10505 increments when BSC executes queuing.

C10506
Definition

Total duration of queuing for successful assignment of voice channel


Description

C10506 represents total duration for queuing in all voice channel


assignment flows. To get the time spend on queuing assignment,
subtract the time when voice channel enters queuing state from the

Confidential and Proprietary Information of ZTE CORPORATION 149


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

current time. To get the total value, C10506 accumulates total time of
queuing assignment.
Measurement Point

C10506 increments after BSC executes queuing operation successfully


and obtains voice channel.

C10507
Definition

Number of successful assignment for queues for voice channel


Description

Initially BSC receives RADIO_APPLY message during channel


assignment flow. If the BSC fails in assigning a voice channel because
of lack of radio resource, it performs queuing. Queuing is successful
within the fixed time and the BSC obtains voice channel.
Measurement Point

C10507 increment, if queuing is successful and BSC acquires voice


channel for MS.

C10508
Definition

Number of assignment for direct retry attempts for voice channel


Description

Initially the BSC fails in applying for a voice channel. Application cause
for voice channel is direct retry or assignment. If the retry condition
meets, BSC executes the direct retry.
Measurement Point

C10508 increments when BSC executes direct retry.

C10509
Definition

Number of assignment execution for voice channel due to directed


retry.
Description

Initially the BSC executes direct retry. C10509 increments, if the BSC
acquires the voice channel for MS.
Measurement Point

C10509 increments when the BSC obtains voice channel.

150 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 8 - Radio Management Module Measurement

C10510
Definition

Number of general assignment for execution for data


Description
Initially the BSC receives RADIO_APPLY message during channel
assignment flow. BSC attempts to assign a data channel. C10510
increments, if data channel assignment is successful.
Measurement Point

C10510 increments when the BSC assigns a data channel successfully.

C10511
Definition

Number of assignment for forced release attempts for data


Description

Initially the BSC receives RADIO_APPLY message during channel


assignment flow and the BSC attempts to assign a data channel. If the
BSC fails in assigning a data channel due to lack of radio resource,
then BSC attempts for forced release and C10511 increments.
Measurement Point

C10511 increments when the BSC attempts for data channel.

C10512
Definition
Number of assignment execution for data due to forced release.
Description
Initially BSC receives RADIO_APPLY message during channel
assignment flow. If BSC fails in assigning a data channel due to lack of
radio resource, the BSC performs forced release. If BSC acquires
required data channel for MS within fixed time and forced release is
successful, C10512 increments.
Measurement Point

C10512 increments when BSC acquires required data channel for MS


within fixed time by forced release.

C10513
Definition

Number of assignment for queuing attempts for data.

Confidential and Proprietary Information of ZTE CORPORATION 151


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Description

Initially BSC receives RADIO_APPLY message during channel


assignment flow. If BSC fails in assigning a data channel and system
does not allow forced release, the BSC attempts for queuing. Queuing
attempt for data channel is successful within fixed time to wait until
system release other data channel. At successful attempt for data
channel after waiting in a queue, C10513 increments.
Measurement Point

C10513 increments when BSC attempts for queuing for data channel.

C10514
Definition

Number of assignment execution for data due to queuing.


Description

Initially the BSC fails in assigning a data channel because no resource


is available. Then the BSC performs queuing operation. If the required
channel is available within fixed time after queuing operation and the
queuing operation is successful, C10514 increment.
Measurement Point

C10514 increments when queuing operation successful and BSC


obtains data channel.

C10515
Definition

Total duration of successful assignment for queuing for data


Description

C10515 represents total duration for queuing in all data channel


assignment flows. To get the time spent on queuing assignment,
subtract the time when the data channel enters queuing state from the
current time. To get the value of C10515, accumulate total time spent
on queuing assignment.
Measurement Point

C10515 increments after BSC executes queuing operation successfully


and obtains data channel.

C10516

Definition

Number of successful assignment of queues for data

152 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 8 - Radio Management Module Measurement

Description

Initially the BSC receives RADIO_APPLY message during channel


assignment flow. If the BTS fails in activating a data channel because
of lack of radio resource, it performs queuing. Queuing is successful
within fixed time and BSC acquires the data channel for MS.
Measurement Point

C10516 increments when queuing is successful and BSC obtains voice


channel

C10517
Definition

Number of assignment for directed retry attempts for data.


Description

Initially the BSC fails in applying for a data channel. Application cause
for data channel is direct retry or assignment. If retry condition is met,
BSC executes the direct retry.
Measurement Point

C10517 increments when BSC executes direct retry.

C10518
Definition

Number of assignment execution for data due to directed retry.


Description

Initially the BSC executes direct retry. C10518 increments, if BSC


acquires the data channel.
Measurement Point

C10518 increments when BSC obtains data channel.

RMM Queue Measurement


RMM Queue Measurement involves counters that provide statistics such as
queuing due to a temporary failure at the time of acquiring radio resources.
These counter include average duration, total duration, number of queues,
and number of successful queues. Unit of the measurement is the cell.

Table 16 lists all RMM queuing counters.

Confidential and Proprietary Information of ZTE CORPORATION 153


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

RMM Queue Counters


TABLE 16 RMM ASSIGNMENT QUEUE COUNTER

Counter No. Counter Definition


C11001 Average length of queue array
C11002 Total duration of queue
C11003 Total number of queues
C11004 Total duration of successful queues
C11005 Total number of successful queues

Above counters not implemented.

154 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 9

RMM Call Drop Measurement

This chapter covers the following topics:

RMM Call Drop Counters

RMM Call Drop Counters


RMM Call Drop Counters provide statistics such as:

SDCCH, TCH/F, and TCH/Hs status.


Signalling, voice, and data type services.
Call drops due to contact loss between RMM and SMM
BTS-site radio link failure and LAPD link failure.
Call drops due to OMC-R force release.

Table 17 lists all RMM call drop counters.

TABLE 17 RMM CALL DROP COUNTERS

Counter No. Counter Definition


C10601 Number of failures due to loss of contact with SMM
C10602 Number of radio link failures
C10603 Number of LAPD link failures
C10604 Number of OMC-R forced releases
C10605 Number of forced releases by other calls
C10606 Number of other failures
C10607 Number of failures due to loss of contact with SMM
C10608 Number of radio link failures
C10609 Number of LAPD link failures
C10610 Number of OMC-R forced releases

Confidential and Proprietary Information of ZTE CORPORATION 155


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Counter No. Counter Definition


C10611 Number of forced releases from other calls
C10612 Number of other failures
C10613 Number of failures due to loss of contact with SMM
C10614 Number of radio link failures
C10615 Number of LAPD link failures
C10616 Number of OMC-R forced releases
C10617 Number of forced releases by other calls
C10618 Number of other failures (On TCH/F voice)
C10619 Number of failures due to loss of contact with SMM
C10620 Number of radio link failures
C10621 Number of LAPD link failures
C10622 Number of OMC-R forced releases
C10623 Number of forced releases by other calls
C10624 Number of other failures
C10625 Number of failures due to loss of contact with SMM
C10626 Number of radio link failures
C10627 Number of LAPD link failures
C10628 Number of OMC-R forced releases
C10629 Number of forced releases by other calls
C10630 Number of other failures
C10631 Number of failures due to loss of contact with SMM
C10632 Number of radio link failures
C10633 Number of LAPD link failures
C10634 Number of OMC-R forced releases
C10635 Number of forced releases by other calls
C10636 Number of other failures
C10637 Number of failures due to loss of contact with SMM
C10638 Number of radio link failures
C10639 Number of LAPD link failures
C10640 Number of OMC-R forced releases
C10641 Number of forced releases by other calls
C10642 Number of other failures
C10643 Number of SDCCH call drops
C10644 Number of TCH/F call drops
C10645 Number of TCH/H call drops
C10646 Call drop on SDCCH due to handover failure
C10647 Call drop on TCH/F signaling due to handover failure

156 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 9 - RMM Call Drop Measurement

Counter No. Counter Definition


C10648 Call drop on TCH/F voice due to handover failure
C10649 Call drop on TCH/F data due to handover failure
C10650 Call drop on TCH/H signaling due to handover failure
C10651 Call drop TCH/H voice due to handover failure
C10652 Call drop on TCH/H data due to handover failure

Call Drop Counters Explanation


C10601
Definition

Number of failures due to loss of contact between RMM and SMM (On
SDCCH)
Description
C10601 represents number of call drops due to contact loss between
RMM and SMM on SDCCH. ZXG10-BSC system consists of one System
Management Module (SMM) and maximum of eight RMMs
During STATUS_QUERY_STATUS_CONFERMATION, RMM sets timer
T12
If timer T12 expires for three times consecutively, the link between
SMM and RMM breaks and counter C10601 increments.
During EST_IND link establishment flow, RMM set Timer T3.
If T3 timer expires, the link between SMM and RMM breaks and
counter C10601 increments.
Measurement Point

C10601 increments when Timer T12 expires for three times


consecutively or timer T3 expires.

C10602
Definition

Number of radio link failures (On SDCCH)


Description

C10603 represents number of call drops due to radio link failure on


SDCCH.
Measurement Point

C10602 increments when BSC receives ABIS_CONNECTFAILIND


message on Abis-interface.

Confidential and Proprietary Information of ZTE CORPORATION 157


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C10603
Definition
Number of LAPD link failures (On SDCCH)
Description

C10603 represents number of call drops due to LAPD link failure on


SDCCH.
Measurement Point

C10603 increments when BSC receives LAPD link break message.

C10604
Definition

Number of OMC-R forced releases (On SDCCH)


Description

C10604 represents number of call drops due to SDCCH forced release.


Measurement Point

C10604 increments when BSC receives force release message from


OMC-R.

C10605
Definition

Number of forced releases by other calls (On SDCCH)


Description

C10605 represents number of call drops due to force release from high
priority calls on SDCCH. Initially BSC receives force release message
from BTS for high priority calls and C10605 increments.
Measurement Point

C10605 increments when BSC receives forced release message from


BTS.

C10606
Definition

Number of other failures (On SDCCH)


Description

C10606 represents number of call drops due to causes other than


above-mentioned cases on SDCCH.

158 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 9 - RMM Call Drop Measurement

Other causes such as:


T3107 timer expires in ASSIGNING status.
T1 timer expires in WAIT_ACCESS status during radio resource
valid to assignment or handover complete.
T3103 timer expires when BSC receives EST_IND from MS during
channel activation.
Measurement Point

C10606 increments when timers T3107, T1, and T3103 expire.

C10607
Definition

Number of failures due to loss of contact between SMM and RMM (On
TCH/F signaling channel)
Description

Counter C10607 represents number of call drops due to loss of contact


between RMM and SMM on TCH/F channel. ZXG10-BSC system
comprises one System Management Module (SMM) and maximum of
eight Radio Management Modules (RMMs)
During STATUS_QUERY_STATUS_CONFERMATION RMM sets timer
T12.
If timer T12 expires for three times consecutively, the link between
SMM and RMM breaks and counter C10607 increments.
During EST_IND link establishment flow, RMM sets Timer T3.
C10607 increments, if T3 timer expires, the link between SMM and
RMM breaks.
Measurement Point

C10607 increments when timer T12 expires for three times


consecutively or timer T3 expires.

C10608
Definition

Number of radio link failures (On TCH/F signaling channel)


Description

C10608 represents number of call drops due to radio link failure on


TCH/F signaling channel.
Measurement Point

C10608 increments when BSC receives ABIS_CONNECTFAILIND


message on Abis-interface.

Confidential and Proprietary Information of ZTE CORPORATION 159


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C10609
Definition

Number of LAPD link failures (On TCH/F signaling channel)


Description

C10609 represents number of call drops due to LAPD link failure on


TCH/F signaling channel.
Measurement Point

C10609 increments when BSC receives LAPD link break message.

C10610
Definition

Number of OMC-R forced releases (On TCH/F signaling channel)


Description

C10610 represents number of call drops due to forced release message


from OMC-R on TCH/F signaling channel.
Measurement Point

C10610 increments when BSC receives forced release message from


OMC-R.

C10611
Definition

Number of forced release of other calls (On TCH/F signaling channel)


Description

C10611 represents number of call drops due to forced release of other


calls on TCH/F signaling channel.
Measurement Point

C10611 increments when BSC receives forced release message form


other calls.

C10612
Definition

Number of other failures (On TCH/F signaling channel)


Description

Counter C10612 represents number of call drops due to other causes


except above-mentioned counters on TCH/F signaling channel.

160 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 9 - RMM Call Drop Measurement

Other causes such as:


T3107 timer expires in ASSIGNING status.
T1 timer expires in WAIT_ACCESS status during radio resource
valid to assignment or handover complete.
T3103 timer expires when BSC receives EST_IND from MS during
channel activation.
Measurement Point

C10612 increments when timers T3107, T1, and T3103 expire.

C10613
Definition

Number of link failures due to loss of contact between SMM and RMM
(On TCH/F voice channel)
Description

Counter C10613 represents number of call drops due to loss of contact


between RMM and SMM on TCH/F channel. ZXG10-BSC system
comprises one System Management Module (SMM) and maximum
eight Radio Management Modules (RMMs)
During TATUS_QUERY_STATUS_CONFERMATION, RMM sets timer
T12.
If timer T12 expires for three times consecutively, the link between
SMM and RMM breaks and counter C10613 increments.
During EST_IND link establishment flow, RMM sets Timer T3.
If T3 timer expires, the link between SMM and RMM breaks and
counter C10613 increments.
Measurement Point

C10613 increments counting when timer T12 expires for three times
consecutively or timer T3 expires.

C10614
Definition

Number of radio link failures (On TCH/F voice channel)


Description
Counter C10614 represents number of call drops due to radio link
failure on TCH/F voice channel.
Measurement Point

C10614 increments when BSC receives ABIS_CONNECTFAILIND


message on Abis-interface.

Confidential and Proprietary Information of ZTE CORPORATION 161


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C10615
Definition

Number of LAPD link failures (On TCH/F voice channel)


Description
C10415 represents number of call drops due to LAPD link failure on
TCH/F voice channel.
Measurement Point

C10615 increments when BSC receives LAPD link break message.

C10616
Definition

Number of forced release of TCH/F voice channel from OMC-R (On


TCH/F voice channel)
Description

C10616 represents number of call drops due to TCH/F voice channel


force release from OMC-R.
Measurement Point

C10616 increments when BSC receives force release message from


OMC-R.

C10617
Definition

Number of forced release of other calls on TCH/F voice channel (On


TCH/F voice channel).
Description

C10617 represents number of call drops due to force release of TCH/F


voice channel.
Measurement Point

C10617 increments when BSC receives force release message from


other calls.

C10618
Definition

Number of other failures (On TCH/F voice channel)


Description

C10618 represents number of call drops due to other causes except


above-mentioned counters on TCH/F voice channel.

162 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 9 - RMM Call Drop Measurement

Other causes are:


T3107 timer expires in ASSIGNING status.
T1 timer expires in WAIT_ACCESS status during radio resource
valid to assignment or handover complete.
T3103 timer expires when BSC receives EST_IND from MS during
channel activation.
Measurement Point

C10618 increments when timers T3107, T1, and T3103 expire.

C10619
Definition

Number of TCH/F data channel failures due to loss of contact between


SMM and RMM (On TCH/F data channel)
Description

C10619 represents number of call drops due to loss of contact between


RMM and SMM on TCH/F data channel. ZXG10-BSC system comprises
one System Management Module (SMM) and maximum eight Radio
Management Modules (RMMs)
During TATUS_QUERY_STATUS_CONFERMATION, RMM sets timer
T12.
If timer T12 expires for three times consecutively, the link between
SMM and RMM breaks and counter C10619 increments.
During EST_IND link establishment flow, RMM sets Timer T3.
C10619 increments if T3 timer expires and link breaks between
SMM and RMM.
Measurement Point

C10619 increments when timer T12 expires for three times


consecutively or the timer T3 expires.

C10620
Definition

Number of radio link failures (On TCH/F data channel)


Description

C10620 represents number of call drops due to radio link failure on


TCH/F data channel.
Measurement Point

C1020 increments when BSC receives ABIS_CONNECTFAILIND


message on Abis-interface.

Confidential and Proprietary Information of ZTE CORPORATION 163


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C10621
Definition

Number of LAPD link failures (On TCH/F data channel)


Description

Counter C10621 represents number of call drops due to LAPD link


failure on TCH/F data channel.
Measurement Point

Counter C10621 increments when BSC receives LAPD link break


message.

C10622
Definition

Number of OMC-R forced release.


Description

Counter C10622 represents number of call drops due to force release


from OMC-R on TCH/F data channel.
Measurement Point

Counter C10622 increments when BSC receives force release message


from OMC-R.

C10623
Definition

Number of forced releases of other calls on TCH/F data channel.


Description

C10623 represents number of call drops due to force release of other


calls on TCH/F data channel.
Measurement Point

C10623 increments when BSC receives force release message from


other calls.

C10624
Definition

Number of other failures (On TCH/F data channel)


Description
Counter C10624 represents number of call drops due to other causes
except above-mentioned counters on TCH/F data channel.
Other causes are:

164 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 9 - RMM Call Drop Measurement

T3107 timer expires in ASSIGNING status.


T1 timer expires in WAIT_ACCESS status during radio resource
valid to assignment or handover complete.
T3103 timer expires when BSC receives EST_IND from MS during
TCH/F data channel activation.
Measurement Point
C10624 increments when timers T3107, T1, and T3103 expire.

C10625
Definition

Number of failures due to loss of contact between SMM and RMM (On
TCH/H signaling channel)
Description

Counter C10625 represents number of call drops due to loss of contact


between RMM and SMM on TCH/F signaling channel. ZXG10-BSC
system comprises one System Management Module (SMM) and
maximum eight Radio Management Modules (RMMs).
During STATUS_QUERY_STATUS_CONFERMATION, RMM sets timer
T12.
If timer T12 expires for three times consecutively, the link between
SMM and RMM breaks and counter C10625 increments.
During EST_IND link establishment flow, RMM sets Timer T3.
C10625 increments if T3 timer expires and link breaks between
SMM and RMM.
Measurement Point

C10625 increments when timer T12 expires for three times


consecutively or timer T3 expires.

C10626
Definition

Number of radio link failures (On TCH/H signaling channel)


Description

C10626 represents number of call drops due to radio link failure on


TCH/H signaling channel.
Measurement Point

C10626 increments when BSC receives Abis Connect_Fail_Ind message


on Abis-interface.

Confidential and Proprietary Information of ZTE CORPORATION 165


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C10627
Definition

Number of LAPD link failures (On TCH/H signaling channel)


Description

C10627 represents number of call drops due to LAPD link failure on


TCH/H signaling channel.
Measurement Point

C10627 increments when BSC receives LAPD link break message


TCH/H signaling channel.

C10628
Definition

Number of TCH/H signaling channel forced releases from OMC-R.


Description

C10628 represents number of call drops due to forced release of


TCH/H signaling channel from OMC-R.
Measurement Point

C10628 increments when BSC receives TCH/H signaling channel forced


release message from OMC-R.

C10629
Definition

Number of forced releases by other calls


Description

C10629 represents the number of call drops due to forced release of


other calls on TCH/H signaling channel.
Measurement Point

C10629 increments when BSC receives forced release message from


other calls.

C10630
Definition

Number of other failures


Description

Counter C10630 represents number of call drops due to other causes


except above-mentioned counters on TCH/H signaling channel.

166 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 9 - RMM Call Drop Measurement

Other causes are:


T3107 timer expires in ASSIGNING status.
T1 timer expires in WAIT_ACCESS status during radio resource
valid to assignment or handover complete.
T3103 timer expires when BSC receives EST_IND from MS during
TCH/F data channel activation.
Measurement Point

C10630 increments when timers T3107, T1, and T3103 expire.

C10631
Description

Number of failures due to loss of contact between SMM and RMM (On
TCH/H voice channel)
Description

Counter C10631 represents number of call drops due to loss of contact


between RMM and SMM on TCH/H voice channel. ZXG10-BSC system
comprises one System Management Module (SMM) and maximum
eight Radio Management Modules (RMMs)
During STATUS_QUERY_STATUS_CONFERMATION, RMM sets timer
T12.
If timer T12 expires for three times consecutively, the link between
SMM and RMM breaks and counter C10631 increments.
During EST_IND link establishment flow, RMM sets Timer T3.
C10631 increments if T3 timer expires and link breaks between
SMM and RMM.
Measurement Point

C10631 increments to count when timer T12 expires for three times
consecutively or timer T3 expires.

C10632
Definition

Number of radio link failures (On TCH/H voice channel)


Description

C10632 represents number of call drops due to radio link failure on


TCH/H voice channel.
Measurement Point

C10632 increments when BSC receives ABIS_CONNECTFAILIND


message on Abis-interface.

Confidential and Proprietary Information of ZTE CORPORATION 167


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C10633
Definition

Number of LAPD link failures (On TCH/H voice channel)


Description

C10633 represents number of call drops due to LAPD link failure on


TCH/H voice channel.
Measurement Point

C10633 increments when BSC receives LAPD link break message.

C10634
Definition

Number of forced release of TCH/H voice channel from OMC-R (On


TCH/H voice channel)
Description

C10634 represents number of call drops due to force release of TCH/H


voice channel from OMC-R.
Measurement Point

C10634 increments when BSC receives TCH/H voice channel forced


release message from OMC-R.

C10635
Definition

Number of forced TCH/H voice channel releases from other calls (On
TCH/H voice channel)
Description

C10635 represents number of call drops due to forced release of other


calls on TCH/H voice channel.
Measurement Point

C10635 increments when BSC receives forced release message from


other calls.

C10636
Definition

Number of other failures (On TCH/H voice channel)


Description

Counter C10636 represents number of call drops due to other causes


except above-mentioned counters on TCH/H voice channel.

168 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 9 - RMM Call Drop Measurement

Other causes are:


T3107 timer expires in ASSIGNING status.
T1 timer expires in WAIT_ACCESS status during radio resource
valid to assignment or handover complete.
T3103 timer expires when BSC receives EST_IND from MS during
TCH/F data channel activation.
Measurement Point

C10636 increments when Timers T3107, T1, and T3103 expire.

C10637
Definition

Number of failures due to loss of contact between SMM and RMM (On
TCH/H data channel)
Description

C10637 represents number of call drops due to loss of contact between


RMM and SMM on TCH/H data channel.
Measurement Point

C10637 increments when timer T12 expires for three times


consecutively or timer T3 expires.

C10638
Definition
Number of radio link failures (On TCH/H data channel)
Description

C10638 represents number of call drops due to radio link failure on


TCH/H data channel.
Measurement Point

C10638 increments when BSC receives ABIS_CONNECTFAILIND


message on Abis-interface.

C10639
Definition

Number of LAPD link failures (On TCH/H data channel)


Description

C10639 represents number of call drops due to LAPD link failure on


TCH/H data channel.

Confidential and Proprietary Information of ZTE CORPORATION 169


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Measurement Point

C10639 increments when BSC receives LAPD link break message.

C10640
Definition

Number of TCH/H data channel forced release from OMC-R (On TCH/H
data channel)
Description

C10640 represents number of call drops due to forced release of


TCH/H data channel from OMC-R on.
Measurement Point

C10640 increments when BSC receives forced release message from


OMC-R.

C10641
Definition

Number of forced releases from calls (On TCH/H data channel)


Description

C10641 represents the number of call drops due to forced release of


other calls on TCH/H data channel.
Measurement Point

C10641 increments when BSC receives forced release message from


other calls.

C10642
Definition

Number of other failures (On TCH/H data channel)


Description

C10642 represents the number of call drops due to other causes


except above-mentioned counters on TCH/H data channel.
Other causes are:
T3107 timer expires in ASSIGNING status.
T1 timer expires in WAIT_ACCESS status during radio resource
valid to assignment or handover complete.
T3103 timer expires when BSC receives EST_IND from MS during
TCH/F data channel activation.
Measurement Point
C10642 increments when Timers T3107, T1, and T3103 expire.

170 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 9 - RMM Call Drop Measurement

C10643
Definition

Number of SDCCH calls drops


Description
Counter C10643 represents number of call drops due to radio link
failure, LAPD broken link and handover failure on SDCCH.
At present, the system does not represent failures due to following four
types of causes:
Loss of contact with the SMM
Forced release from OMC-R
Forced release by other calls
Any other causes
Measurement Point

C10643 increments due to radio link, LAPD link and handover failure.

C10644
Definition

Number of TCH/F calls drops


Description

C10644 represents number of call drops due to radio link failure, LAPD
link break and handover failure on TCH/F channel.
At present, the system does not represent the failures due to following
four types of causes:
Loss of contact with the SMM
Forced release from OMC-R
Forced release by other calls
Any other causes
Measurement Point

C10644 increments due to radio link failure, LAPD link break and
handover failure.

C10645
Definition

Number of TCH/H calls drops

Confidential and Proprietary Information of ZTE CORPORATION 171


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Description

C10645 represents the number of call drops due to all causes on


TCH/H that includes above-mentioned radio link failure, LAPD link
break and handover failure.
At present, the system does not represent the failures due to following
four types of causes:
Loss of contact with the SMM
Forced release from OMC-R
Forced release by other calls
Any other causes
Measurement Point

C10645 increments when radio link fails, LAPD link breaks and
handover fails.

C10646
Definition

Call drop on SDCCH due to handover failure


Description

C10646 represents the total number of call drops due to handovers on


SDCCH.
Measurement Point

C10646 increments when Timers T3103, 3107, and T8 expire.

C10647
Definition

Call drop due to handover failure on TCH/F signaling


Description
C10647 represents the total number of call drops due to handovers on
TCH/F signaling channel.
Measurement Point

C10647 increments when timers T3103, T3107, and T8 expire.

C10648
Definition
Call drop due to handover failure on TCH/F voice

172 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 9 - RMM Call Drop Measurement

Description

C10648 represents total number of call drops due to handovers on


TCH/F voice channel.
Measurement Point

C10648 increments when timers T3103, 3107, and T8 expire

C10649
Description

Call drop due to handover failure on TCH/F data


Description

C10649 represents total number of call drops due to handovers on


TCH/F data channel.
Measurement Point

C10649 increments when timers T3103, 3107, and T8 expire.

C10650
Definition

Call drop due to handover failure on TCH/H signaling


Description

C10650 represents the total number of call drops due to handovers on


TCH/H signaling channel.
Measurement Point

C10650 increments when timers T3103, 3107, and T8 expire.

C10651
Definition

Call drop due to handover failure (On TCH/H voice)


Description

C10651 represents total number of call drops due to handovers on


TCH/H voice channel.
Measurement Point

Counter C10651 increments when timers T3103, 3107, and T8 expire.

C10652
Definition

Call drop due to handover failure (On TCH/H data)

Confidential and Proprietary Information of ZTE CORPORATION 173


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Description

C10652 represents the total number of call drops due to handovers on


TCH/H data channel.
Measurement Point

C10652 increments when timers T3103, 3107, and T8 expire.

174 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10

Handover Cause
Measurement

This chapter covers the following topics:

Handover Cause Counters

Handover Cause Counters


Handover Cause Counters provides statistics for number of handover out
attempts due to various handover causes. BSC determines the handover
upon MS measurement report. Handover measurement reports are of
great significance at the time of evaluation, adjustment and RF
parameters optimization of the network.

Handover Cause Counters


Table 18 lists handover cause counters.

TABLE 18 HANDOVER CAUSE COUNTERS

Counter No. Counter Definition


C10801 Number of handover attempts due to direct retry
C10802 Number of handover attempts due to uplink received strength (on SDCCH)
Number of handover attempts due to downlink received strength (on
C10803
SDCCH)
C10804 Number of handover attempts due to uplink interference (on SDCCH)
C10805 Number of handover attempts due to downlink interference(on SDCCH)
C10806 Number of handover attempts due to C/I RATIO (on SDCCH)
C10807 Number of handover attempts due to PBGT (on SDCCH)
C10808 Number of handover attempts due to large TA (on SDCCH)
C10809 Number of handover attempts due to MSC request (on SDCCH)
C10810 Number of handover attempts due to traffic (on SDCCH)

Confidential and Proprietary Information of ZTE CORPORATION 175


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Counter No. Counter Definition


C10811 Handover attempt due to any other reason (on SDCCH)
C10812 Handover attempt due to uplink received strength (on TCH/F)
C10813 Handover attempt due to downlink received strength (on TCH/F)
C10814 Handover attempt due to uplink interference (on TCH/F)
C10815 Handover attempt due to downlink interference (on TCH/F)
C10816 Handover attempt due to C/I RATIO (on TCH/F)
C10817 Handover attempt due to PBGT (on TCH/F)
C10818 Handover attempt due to large TA (on TCH/F)
C10819 Handover attempt due to MSC request (on TCH/F)
C10820 Handover attempt due to traffic (on TCH/F)
C10821 Handover attempt due to any other reason (on TCH/F)
C10822 Handover attempt due to uplink received strength (on TCH/H)
C10823 Handover attempt due to downlink received strength (on TCH/H)
C10824 Handover attempt due to uplink interference (on TCH/H)
C10825 Handover attempt due to downlink interference (on TCH/H)
C10826 Handover attempt due to C/I RATIO (on TCH/H)
C10827 Handover attempt due to PBGT (on TCH/H)
C10828 Handover attempt due to large TA (on TCH/H)
C10829 Handover attempt due to MSC request (on TCH/H)
C10830 Handover attempt due to traffic (on TCH/H)
C10831 Handover attempt due to any other reason (on TCH/H)
C10832 Handover attempt due to increased TA in extension cell (on TCH/F)
C10833 Handover attempt due to decreased TA in extension cell (on TCH/F)
C10834 Handover attempt due to uplink quality (on SDCCH)
C10835 Handover attempt due to downlink quality (on SDCCH)
C10836 Handover attempt due to uplink quality (on TCH/F)
C10837 Handover attempt due to downlink quality (on TCH/F)
Handover attempt due to a good standard level in 3G adjacent cell (on
C10838
TCH/F)
C10839 Handover attempt due to uplink quality (on TCH/H)
C10840 Handover attempt due to downlink quality (on TCH/H)
Handover attempt due to good standard level in 3G adjacent cell (on
C10841
TCH/H)
C10842 Handover attempt due to increased TA in extension cell (on TCH/H)
C10843 Handover attempt due to decreased TA in extension cell (on TCH/H)
C10844 Number of forced transfer handover attempts
C10845 Number of forced handovers during assignment
C10846 Number of forced handovers during handover

176 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - Handover Cause Measurement

Handover Cause Counters Explanation


C10801
Definition

Handover attempts due to direct retry


Description

C10801 represents number of handover attempts due to directed retry.


In this case, handovers are intra-BSC inter cell and external handover.
C10802 triggers due to the DIRECTED RETRY in serving cell when
serving cell has congestion during assignments.
Measurement Point

During intra-BSC inter-cell handover, C10802 increments when serving


cell sends RADIO APPLY message due to DIRECT RETRY. Similarly,
during external, C10802 increments when serving cell sends
HANDOVER REQUIRED due to DIRECT RETRY.

C10802
Definition

Handover attempt due to uplink receive strength (on SDCCH)


Description

C10802 represents numbers of handovers due to uplink receive


strength. Counter records for both internal and external handovers.
C10802 triggers due to uplink received strength on SDCCH of the
serving cell.
Measurement Point

During intra-cell and inter-cell handover (intra-BSC), C10802


increments when serving cell sends RADIO APPLY message due to
uplink receiving strength. Similarly, during external handover (intra-
BSC) C10802 increments when serving cell sends HANDOVER
REQUIRED due to uplink receiving strength.

C10803
Definition

Handover attempt due to downlink receive strength (on SDCCH)


Description

C10803 represents numbers of number of handover attempts due to


downlink receive strength. Counter records for both internal and
external handovers.

Confidential and Proprietary Information of ZTE CORPORATION 177


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Measurement Point

During intra-cell and inter-cell handover (intra-BSC), counter C10803


increments when serving cell sends RADIO APPLY message due to
down link receiving strength. Similarly, during external handover,
C10803 increments when the serving cell sends HANDOVER REQUIRED
due to down link receiving strength.

C10804
Definition

Handover attempt due to uplink interference (on SDCCH)


Description

C10804 represents number of handovers due to uplink interference.


Counter records for both internal and external handovers.
Measurement Point

During intra-cell and inter-cell handover (intra-BSC), C10804


increments when serving cell sends RADIO APPLY message due to
uplink interference. Similarly, during external handover, C10804
increments when serving cell sends HANDOVER REQUIRED due to
uplink interference.

C10805
Definition

Handover attempt due to downlink interference (on SDCCH)


Description

C10805 represents number of handovers due to downlink interference.


Counter records for both internal and external handovers.
Measurement Point

During intra-cell and inter-cell handover (intra-BSC), C10805


increments when serving cell sends RADIO APPLY message due to
downlink interference. Similarly, during external handover, C10805
increments when serving cell sends HANDOVER REQUIRED due to
downlink interference.

C10806
Definition
Handover attempt due to C/I RATIO (on SDCCH)
Description

C10806 represents number of handovers due to C/I RATIO on SDCCH.


Counter records for both internal and external handovers.

178 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - Handover Cause Measurement

Measurement Point

During intra-cell and inter-cell handover (intra-BSC), C10806


increments when serving cell sends RADIO APPLY message due to C/I
RATIO. Similarly, during external handover, C10806 increments when
serving cell sends HANDOVER REQUIRED due to C/I ratio.

C10807
Definition

Handover attempt due to PBGT (on SDCCH)


Description

C10807 represents number of handovers due to PBGT on SDCCH.


Counter records for both internal and external handovers.
Measurement Point
During intra-cell and inter-cell handover, C10807 increments when
serving cell sends RADIO APPLY message due to PBGT. Similarly,
during external handover, C10807 increments when serving cell sends
HANDOVER REQUIRED due to PBGT.

C10808
Definition

Handover attempt due to large TA (on SDCCH)


Description

C10808 represents number of handovers due to large TA on SDCCH.


Counter records for both internal and external handovers.
Measurement Point

During intra-cell and inter-cell handover, C10808 increments when


source cell sends RADIO APPLY message due to large TA. Similarly,
during external handover, C10808 increments when source cell sends
HANDOVER REQUIRED due to large TA.

C10809
Definition

Handover attempt due to MSC request (on SDCCH)


Description

C10809 represents number of handovers due to MSC request on


SDCCH. Counter records for both internal and external handovers.
Measurement Point

C10809 increments when serving cell receive HANDOVER ENQUERY


message from MSC and sends HANDOVER REQUIRED message to MSC.

Confidential and Proprietary Information of ZTE CORPORATION 179


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C10810
Definition

Handover attempt due to traffic (on SDCCH)


Description

C10810 represents number of handovers due to traffic overload on


SDCCH. Counter records for both internal and external handovers.
Measurement Point

Database makes a judgment based on utilizations of serving cell


resources and the cell sets threshold. If the traffic exceeds the
threshold, BSC sends a message that indicates that cell service is
overloaded.
During inter-cell handover, C10810 increments when source cell
receives message that indicates that cell service is overloaded and it
sends RADIO APPLY message.
Similarly, during handover out C10810 increments when source cell
receives message that indicates that cell service is overloaded and it
sends HANDOVER REQUIRED.

C10811
Definition

Handover attempt due to any other cause


Description

Counter C10811 represents number of handovers on SDCCH of serving


cell due to causes other than above-mentioned causes. Other causes
such as fast movement of MS, feeding dips or handover fill-in abnormal.
Counter records for both internal and external handovers.
Measurement Point

C10811 increments when serving cell sends Radio Apply message to


BSC during intra-cell handover and inter-cell handover on SDCCH in
BSC. Similarly, the C10811 increments when serving cell sends
HANDOVER REQUIRED message during external handover on SDCCH
due to other causes.

C10812
Definition

Handover attempt due to uplink received signal strength


Description

C10812 represents number of handovers due to uplink received signal


strength on TCH/F. Counter records for both internal and external
handovers. C10812 triggers due to uplink received strength on TCH/F
channel of serving cell.

180 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - Handover Cause Measurement

Measurement Point

During intra-cell and inter-cell handover, C10812 increments when


serving cell sends RADIO APPLY message due to uplink receiving
strength. Similarly, during external handover, C10812 increments
when serving cell sends HANDOVER REQUIRED due to uplink receiving
strength.

C10813
Definition

Handover attempt due to downlink received signal strength


Description

C10813 represents number of handovers due to downlink received


signal strength on TCH/F in serving cell. Counter records for both
internal and external handovers. C10813 triggers due to downlink
received signal strength on TCH/F channel of serving cell.
Measurement Point

During intra-cell and inter-cell handover, counter C10813 increments


when serving cell sends RADIO APPLY message due to downlink
receive strength. Similarly, during external handover C10813
increments when serving cell sends HANDOVER REQUIRED due to
downlink received signal strength.

C10814
Definition

Handover attempt due to uplink interference


Description

Counter C10814 represents number of handovers due to uplink


interference on TCH/F of serving cell. Counter records for both internal
and external handovers..
Measurement Point

During intra-cell and inter-cell handover, C10814 increments when


serving cell sends RADIO APPLY message due to uplink interference on
TCH/F. Similarly, during external handover C10814 increments when
serving cell sends HANDOVER REQUIRED due to uplink interference on
TCH/F.

C10815
Definition

Handover attempt due to downlink interference

Confidential and Proprietary Information of ZTE CORPORATION 181


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Description

C10815 represents number of handovers due to downlink interference


on TCH/F of serving cell. Counter records for both internal and external
handovers.
Measurement Point

During intra-cell and inter-cell handover, C10815 increments when


serving cell sends RADIO APPLY message due to downlink interference
on TCH/F. Similarly, during external handover C10815 increments
when serving cell sends HANDOVER REQUIRED due to downlink
interference on TCH/F.

C10816
Definition

Handover attempt due to C/I RATIO


Description

C10816 represents number of handovers due to C/I RATIO on TCH/F of


serving cell. Counter records for both internal and external handovers..
Measurement Point

During intra-cell and inter-cell handover, C10816 increments when


serving cell sends RADIO APPLY message due to C/I RATIO on TCH/F.
Similarly, during external handover C10816 increments when serving
cell sends HANDOVER REQUIRED due to C/I RATIO on TCH/F.

C10817
Definition

Handover attempt due to PBGT


Description

C10817 represents number of handovers due to PBGT on TCH/F of


serving cell. Counter records for both internal and external handovers.
Measurement Point

During intra-cell and inter-cell handover, C10817 increments when


serving cell sends RADIO APPLY message due to PBGT on TCH/F.
Similarly, during external handover C10817 increments when serving
cell sends HANDOVER REQUIRED due to PBGT on TCH/F.

C10818
Definition

Handover attempt due to large TA

182 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - Handover Cause Measurement

Description

C10818 represents number of handovers due to large TA on TCH/F of


serving cell. Counter records for both internal and external handovers.
Measurement Point

During intra-cell and inter-cell handover, C10818 increments when


serving cell sends RADIO APPLY message due to large TA on TCH/F.
Similarly, during external handover C10818 increments when serving
cell sends HANDOVER REQUIRED due to large TA on TCH/F.

C10819
Definition

Handover attempt due to MSC request


Description

C10819 represents number of handovers due to MSC request on TCH/F


of serving cell. Counter records for both internal and external
handovers.
Measurement Point

C10819 increments when serving cell receive HANDOVER ENQUERY


message from MSC and sends HANDOVER REQUIRED message to MSC.

C10820
Definition

Handover attempt due to traffic over load


Description

C10820 represents number of handovers due to traffic overload on


TCH/F of serving cell. Counter records for both internal and external
handovers.
Measurement Point

Database makes a judgment based on utilizations of serving cell


resources and the cell sets threshold. If the traffic exceeds the
threshold, BSC sends a message that indicates that cell service is
overloaded.
During inter-cell handover, C10820 increments when source cell
receives message that indicates that cell service is overloaded and it
sends RADIO APPLY message.
Similarly, during handover out C10820 increments when source cell
receives message that indicates that cell service is overloaded and it
sends HANDOVER REQUIRED.

Confidential and Proprietary Information of ZTE CORPORATION 183


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C10821
Definition

Handover attempt due to any other cause


Description

C10821 represents number of handovers on TCH/F channel of serving


cell due to causes other than the above. Other causes are fast
movement of MS, feeding dips or handover fill-in abnormal. Counter
records for both internal and external handovers.
Measurement Point

C10821 increments when serving cell sends Radio Apply message to


BSC during intra-cell handover and inter-cell handover on TCH/F
channel in BSC. Similarly C10821 increments when serving cell sends
HANDOVER REQUIRED message during external handover on TCH/F
due to other causes.

C10822
Definition

Handover attempt due to uplink received signal strength


Description

C10822 represents number of handovers due to uplink received signal


strength on TCH/H. Counter records for both internal and external
handovers. C10822 triggers due to uplink received signal strength on
the TCH/H of serving cell.
Measurement Point

During intra-cell and inter-cell handover, C10822 increments when


serving cell sends RADIO APPLY message due to uplink receiving
strength.
Similarly, during external handover C10822 increments when serving
cell sends HANDOVER REQUIRED due to uplink receiving strength.

C10823
Definition

Handover attempt due to downlink received strength


Description

C10823 represents number of handovers due to downlink received


signal strength on TCH/H in serving cell. C10823 triggers due to
downlink received strength on the TCH/H of serving cell
Measurement Point

During intra-cell and inter-cell handover, C10823 increments when


serving cell sends RADIO APPLY message due to downlink receive

184 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - Handover Cause Measurement

strength. Similarly, during external handover C10823 increments when


serving cell sends HANDOVER REQUIRED due to downlink receive
strength.

C10824
Definition

Handover attempt due to uplink interference


Description

Counter C10824 represents number of handovers due to uplink


interference on TCH/H of serving cell. Counter records for both internal
and external handovers.
Measurement Point

During intra-cell and inter-cell handover, counter C10824 increments


when serving cell sends RADIO APPLY message due to uplink
interference on TCH/H. Similarly, during external handover C10824
increments when serving cell sends HANDOVER REQUIRED due to
uplink interference on TCH/H.

C10825
Definition

Handover attempt due to downlink interference


Description

C10825 represents number of handovers due to downlink interference


on TCH/H of serving cell. Counter records for both internal and
external handovers.
Measurement Point

During intra-cell and inter-cell handover, C10825 increments when


serving cell sends RADIO APPLY message due to downlink interference
on TCH/F. Similarly, during external handover C10825 increments
when serving cell sends HANDOVER REQUIRED due to downlink
interference on TCH/F

C10826
Definition

Handover attempt due to C/I RATIO


Description

C10826 represents number of handover attempts due to C/I RATIO on


TCH/H of serving cell. Counter records for both internal and external
handovers.

Confidential and Proprietary Information of ZTE CORPORATION 185


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Measurement Point

During intra-cell and inter-cell handover, C10826 increments when


serving cell sends RADIO APPLY message due to C/I RATIO on TCH/H.
Similarly, during external handover C10826 incremented when source
cell sends HANDOVER REQUIRED due to C/I RATIO on TCH/H.

C10827
Definition

Handover attempt due to PBGT


Description

C10827 represents number of handovers due to PBGT on TCH/H of


serving cell. Counter records for both internal and external handovers.
Measurement Point

During intra-cell and inter-cell handover, C10827 increments when


serving cell sends RADIO APPLY message due to PBGT on TCH/H.
Similarly, during external handover C10827 increments when serving
cell sends HANDOVER REQUIRED due to PBGT on TCH/H.

C10828
Definition

Handover attempt due to large TA


Description

C10828 represents number of handovers due to large TA on TCH/F of


serving cell. Counter records for both internal and external handovers..
Measurement Point

During intra-cell and inter-cell handover, C10828 increments to count


when serving cell sends RADIO APPLY message due to large TA on
TCH/H. Similarly, during external handover the counter C10828
increments to count when serving cell sends HANDOVER REQUIRED
due to large TA on TCH/H.

C10829
Definition

Handover attempt due to MSC request


Description

C10829 represents number of handovers due to MSC request on


TCH/H of serving cell. Counter records for both internal and external
handovers.

186 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - Handover Cause Measurement

Measurement Point

C10829 increments when serving cell receive HANDOVER ENQUERY


message from MSC and sends HANDOVER REQUIRED message.

C10830
Definition

Handover attempt due to traffic


Description

C10830 represents number of handovers due to traffic overload on


TCH/H of serving cell. Counter records for both internal and external
handovers.
Measurement Point

Database makes a judgment based on utilizations of serving cell


resources and the cell sets threshold. If the traffic exceeds the
threshold, BSC sends a message that indicates that cell service is
overloaded.
During inter-cell handover, C10830 increments when source cell
receives message that indicates that cell service is overloaded and it
sends RADIO APPLY message.
Similarly, during handover out C10830 increments when source cell
receives message that indicates that cell service is overloaded and it
sends HANDOVER REQUIRED.

C10831
Definition

Handover attempt due to any other cause


Description

C10831 represents number of handovers on TCH/H of serving cell due


to other than above-mentioned causes. Other causes are fast
movement of MS, feeding dips or handover fill-in abnormal. Counter
records for both internal and external handovers.
Measurement Point

C10831 increments when serving cell sends Radio Apply message to


BSC during intra-cell handover and inter-cell handover on TCH/H in
BSC. Similarly counter C10831 increments when serving cell sends
HANDOVER REQUIRED message during external handover on TCH/H
due to other causes.

C10832
Definition

Handover attempt due to increase in TA in extension cell (on TCH/F)

Confidential and Proprietary Information of ZTE CORPORATION 187


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Description

C10832 represents number of intra-cell intra-BSC and intra-BSC inter-


cell handovers due to large TA on TCH/F channel in current extension
cell. Initially subscriber is on TCH/F of common cell TRX. If TA value is
too high, BSC handovers subscriber from common cell TRX to
extension cell TRX.
Measurement Point

C10832 increments when common cell sends RADI APPLY message due
to increased TA on TCH/F.

C10833
Definition

Handover attempt due to decreased TA in extension cell (on TCH/F)


Description

C10833 represents number of intra-cell and inter-cell handovers due to


decrease in TA on TCH/F channel of current extension cell. Initially
subscriber is in TCH/F channel of extension cell TRX. If TA value
decreases, BSC handovers subscriber from extension cell TRX to
common cell TRX.
Measurement Point

C10833 increments when extension cell sends RADI APPLY message


due to increased TA on TCH/F.

C10834
Definition

Handover attempt due to uplink quality (on SDCCH)


Description

Counter C10834 represents number of handover attempts due to


uplink quality on SDCCH of serving cell. Counter records for both
internal and external handovers.
Measurement Point

During intra-cell and inter-cell handover, C10834 increments when


serving cell sends RADIO APPLY message due to uplink quality.
Similarly, during external handover C10834 increments when serving
cell sends HANDOVER REQUIRED due to uplink quality.

C10835
Definition
Handover attempt due to downlink quality (on SDCCH)

188 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - Handover Cause Measurement

Description

Counter C10835 represents number of handover attempts due to


downlink quality on SDCCH of serving cell. Counter records for both
internal and external handovers.
Measurement Point

During intra-cell and inter-cell handover, C10834 increments when


serving cell sends RADIO APPLY message due to downlink quality.
Similarly, during external handover C10834 increments when serving
cell sends HANDOVER REQUIRED due to downlink quality.

C10836
Definition

Handover attempt due to uplink quality (on TCH/F)


Description

C10836 represents number of handover attempts due to uplink quality


on TCH/F of serving cell. Counter records for both internal and external
handovers.
Measurement Point

During intra-cell and inter-cell handover, C10836 increments when


serving cell sends RADIO APPLY message due to uplink quality of
TCH/F. Similarly, during external handover C10836 increments when
serving cell sends HANDOVER REQUIRED due to uplink quality of
TCH/F.

C10837
Definition
Handover attempt due to downlink quality (on TCH/F)
Description
C10837 represents number of handover attempts due to downlink
quality on TCH/F of serving cell. Counter records for both internal and
external handovers.
Measurement Point

During intra-cell and inter-cell handover, C10837 increments when


serving cell sends RADIO APPLY message due to downlink quality of
TCH/F. Similarly, during external handover C10837 increments when
serving cell sends HANDOVER REQUIRED due to downlink quality of
TCH/F.

Confidential and Proprietary Information of ZTE CORPORATION 189


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C10838
Definition

Number of handover attempts due to a good standard level of TCH/F in


3G adjacent cell (ON TCH/F)
Description

C10838 represents number of handovers due to good signal strength


of TCH/F in 3G adjacent cells. In this case, handover is out of BSC
between BSC and RNC.
Measurement Point

C10838 increments when serving cell sends HANDOVER REQUIRED due


to good signal strength of TCH/F in 3G adjacent cell.

C10839
Definition

Handover attempt due to uplink quality (on TCH/H)


Description

C10839 represents number of handover attempts due to uplink quality


on TCH/H of serving cell. Counter records for both internal and
external handovers..
Measurement Point

During intra-cell and inter-cell handover, counter C10839 increments


when serving cell sends RADIO APPLY message due to uplink quality of
TCH/H. Similarly, during external handover C10839 increments when
serving cell sends HANDOVER REQUIRED due to uplink quality of
TCH/H.

C10840
Definition

Handover attempt due to downlink quality (on TCH/H)


Description

C10840 represents number of handover attempts due to downlink


quality on TCH/H of serving cell. Counter records for both internal and
external handovers.
Measurement Point

During intra-cell and inter-cell handover counter C10840 increments


when serving cell sends RADIO APPLY message due to downlink quality
of TCH/H. Similarly, during external handover C10840 increments
when serving cell sends HANDOVER REQUIRED due to downlink quality
of TCH/H.

190 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 10 - Handover Cause Measurement

C10841
Definition

Handover attempt due to a good standard level of TCH/H in 3G


adjacent cell (ON TCH/H)
Description

C10841 represents number of handover due to good signal strength of


TCH/H in 3G adjacent cells. In this case, handover is out of BSC
between BSC and RNC.
Measurement Point

C10841 increments when serving cell sends HANDOVER REQUIRED due


to good signal strength of TCH/F in 3G adjacent cell.

C10842
Definition

Handover attempt due to increased TA in extension cell (on TCH/H)


Description

C10842 represents number of intra-cell and inter-cell handovers due to


increase in TA on TCH/H of current extension cell. Initially subscriber is
on TCH/H of TRX of common cell. If TA value is too high, BSC
handovers subscriber from common cell TRX to extension cell TRX.
Measurement Point

C10842 increments when common cell sends RADIO APPLY message to


BSC due to increased TA.

C10843
Definition

Handover attempt due to decreased TA in extension cell (on TCH/H)


Description

C10843 represents number of intra-cell and inter-cell handovers due to


decrease in TA on TCH/H of current extension cell. Initially subscriber
is on TCH/H of common cell TRX. If TA value is too low, BSC handovers
subscriber from extension cell TRX to common cell TRX.
Measurement Point

C10843 increments when extension cell sends RADIO APPLY message


to BSC due to decreased TA

Confidential and Proprietary Information of ZTE CORPORATION 191


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C10844
Definition

Number of forced transfer handover attempts


Description

BSC can not handover users of a cell to other neighboring cell due to
downlink path loss and low TA value. This situation creates congestion.
When BSC allows forced transfer, BSC forcedly handover users of a cell
to other neighboring cell to avoid possible congestion.
Measurement Point

C10844 increments when condition for force transfer of a handover


satisfies in a cell and BTS sends RADIO APPLY message to BSC.

C10845
Definition

Number of forced handovers during assignment


Description

BSC can not handover the users in a cell to other neighboring cell due
to downlink path loss and low TA value. This situation creates
congestion. When BSC allows forced transfer, BSC forcefully handover
users of a cell to other neighboring cell to avoid possible congestion.
Measurement Point

C10846
Definition

Number of forced handovers during handover


Description

If parameter configuration allows forced handover in and there are


rescue handover requests from high priority subscribers, or, there are
external handover in or handover requests indicating pre-empt of
channels but no channels available in the object cell, in such a case, a
low priority subscriber who has seize channel will be found and be
switched to adjacent cell, the released channel will be assigned to the
high priority subscriber
Measurement Point

A low priority subscriber, who has seized channel, has been found in
handover. Counter increments when the ‘ForcedHoApply’ message is
sent to the subscriber.

192 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 11

General Handover
Measurement

This chapter covers the following topics:

Handover Counters

Handover Counters
General Handover measurement involves handover counters that provide
statistics for handover processes that arises from all types of handover
causes. These counters show handover success ratio, number of handover
attempts, execution, success and failure. This chapter analyzes handover
in aspect of the control entity and provides statistics for both the
executions and handover successes. These counters show statistics for
request, success and failure of intra-cell handover, intra-BSC inter-cell
handover and intra-MSC handover.

Table 19 lists all the handover counters.

TABLE 19 HANDOVER COUNTERS

Counter No. Counter Definition


C10901 Number of Intra-BSC inter-cell handover outs
C10902 Number of Intra-BSC inter-cell handover out executions
C10903 Number of successful Intra-BSC inter-cell handover outs
C10904 Number of MSC-controlled handover out attempts
Number of number of MSC-controlled handover out request failures due
C10905
to unclear causes
Number of MSC-controlled handover out request failures due to
C10906
unavailable ground resource
Number of MSC-controlled handover out requests failures due to
C10907
unavailable wireless resource

Confidential and Proprietary Information of ZTE CORPORATION 193


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Counter No. Counter Definition


Number of MSC-controlled handover out request failures due to other
C10908
causes
C10909 Number of MSC-controlled handover out executions
C10910 Number of successful MSC-controlled handover outs
C10911 Number of Intra-BSC inter-cell handover in attempts
C10912 Number of Intra-BSC inter-cell handover in attempts
C10913 Number of successful Intra-BSC inter-cell handover ins
C10914 Number of Intra-BSC handover in attempts
C10915 Number of MSC-controlled handover in attempts for general handover
C10916 Number of MSC-controlled handover ins due to forced-release attempt
C10917 Number of MSC-controlled handover in attempts due to forced release
C10918 Number of MSC-controlled handover ins due to queue attempts
C10919 Number of MSC-controlled handover ins attempts due to queue
C10920 Number of successful MSC-controlled handover ins
C10921 Number of MSC-controlled total handover ins due to queue
C10922 Number of MSC-controlled handover ins due to queues
C10923 Number of successful MSC-controlled total handover ins due to queue
C10924 Number of MSC-controlled successful handover ins due to queues
Number of handover in attempts from the same layer and same
C10925
frequency
Number of successful handover ins from the same layer and same
C10926
frequency
C10927 Number of handover in attempts to the same layer and same frequency
Number of successful handover ins to the same layer and same
C10928
frequency
Number of handover in attempts from undefined layer and to the same
C10929
frequency
Number of successful handover ins from undefined layer and to the
C10930
same frequency
Number of handover in attempts to undefined layer and same
C10931
frequency
Number of successful handover out to undefined layer and same
C10932
frequency
Number of incoming handover attempts from undefined layer GSM900
C10933
to current layer GSM1800
Number of handover in executions from undefined layer (GSM900) to
C10934
current layer (GSM1800)
Number of successful handover ins from undefined layer (GSM900) to
C10935
current layer (GSM1800 )
Number of handover out attempts from undefined layer (GSM900) to
C10936
current layer (GSM1800z)

194 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 11 - General Handover Measurement

Counter No. Counter Definition


Number of successful handover outs from undefined layer (GSM900) to
C10937
current layer (GSM1800z)
Number of handover in attempts from undefined layer (GSM1800) to
C10938
current layer (GSM900)
Number of handover in attempts from undefined layer (GSM1800) to
C10939
current layer (GSM900)
Number of successful handover ins from undefined layer (GSM1800) to
C10940
current layer (GSM900)
Number of handover out attempts from undefined layer (GSM1800) to
C10941
current layer (GSM900)
Number of successful handover outs to undefined layer (GSM1800) to
C10942
current layer (GSM900)
C10943 Number of handover in attempts from upper layer and same frequency
Number of successful handover ins from upper layer and same
C10944
frequency
C10945 Number of handover out attempts to upper layer and same frequency
C10946 Number of successful handover outs to upper layer and same frequency
C10947 Number of handover in attempts from lower layer and same frequency
C10948 Number of successful handover in from lower layer and same frequency
C10949 Number of handover out attempts to lower layer and same frequency
C10950 Number of successful handover out to lower layer and same frequency
Number of handover in attempts at same layer and from GSM900 to
C10951
GSM1800
Number of handover in attempts at same layer and from GSM900 to
C10952
GSM1800
Number of successful handover ins at same layer and from GSM900 to
C10953
GSM1800
Number of handover-out attempt to same layer and from GSM900 to
C10954
GSM1800
Number of successful handover out to same layer and from GSM900 to
C10955
GSM1800
Number of handover in attempts at upper layer and from GSM900 to
C10956
GSM1800
Number of handover in attempts at upper layer and from GSM900 to
C10957
GSM1800
Number of successful handover ins at upper layer and from GSM900 to
C10958
GSM1800
Number of handover out attempts to upper layer and from GSM900 to
C10959
GSM1800
Number of successful handover outs to upper layer and from GSM900
C10960
to GSM1800
Number of handover in attempt at lower layer and from GSM900 to
C10961
GSM1800
C10962 Number of handover in attempts at lower layer and from GSM900 to

Confidential and Proprietary Information of ZTE CORPORATION 195


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Counter No. Counter Definition


GSM1800
C10963 Number of handover in at lower layer and from GSM900 to GSM1800
Number of successful handover out attempts to lower layer and from
C10964
GSM900 to GSM1800
Number of successful handover out to the lower layer and from GSM900
C10965
to GSM1800
Number of handover in attempts at same layer and from GSM1800 to
C10966
GSM900
Number of handover in attempts at same layer and from GSM1800 to
C10967
GSM900
Number of successful handover in from same layer and from GSM1800
C10968
to GSM900
Number of handover out attempts to same layer and from GSM1800 to
C10969
GSM900
Number of successful handover out to same layer and from GSM1800 to
C10970
GSM900
Number of handover in attempts at upper layer and from GSM1800 to
C10971
GSM900
Number of handover in attempts at upper layer and from GSM1800 to
C10972
GSM900
Number of successful handover ins at upper layer and different
C10973
frequencies (1800 MHz → 900 MHz)
Number of handover out attempts to upper layer and from GSM1800 to
C10974
GSM900
Number of successful Handover-out to the upper layer and from
C10975
GSM1800 to GSM900
Number of handover in attempts at lower layer and from GSM1800 to
C10976
GSM900
Number of handover in attempts at lower layer and from GSM1800 to
C10977
GSM900
Number of successful handover in at lower layer and from GSM1800 to
C10978
GSM900
Number of handover out attempts to lower layer and from GSM1800 to
C10979
GSM900
Number of successful handover outs to lower layer and from GSM1800
C10980
to GSM900
C10981 Number of intra-cell handover attempts
C10982 Number of intra-cell successful handovers
C10983 Number of intra-cell inner-circle-to-outer-circle handover attempts
C10984 Number of intra-cell successful inner-circle-to-outer-circle handovers
C10985 Number of intra-cell outer-circle-to-inner-circle handover attempts
C10986 Number of successful intra-cell outer-circle-to-inner-circle handovers
C10987 Number of intra-cell inner-circle-to-inner-circle handover attempts
C10988 Number of successful intra-cell inner-circle-to-inner-circle handovers

196 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 11 - General Handover Measurement

Counter No. Counter Definition


C10989 Number of intra-cell outer-circle-to-outer-circle handover attempts
Number of successful intra-cell successful outer-circle-to-outer-circle
C10990
handovers
C10991 Number of handover out executions from GSM1800 to GSM900
C10992 Number of handover out executions from GSM900 to GSM1800
C10993 Number of 2G to 3G handover attempts
C10994 Number of 2G to 3G handover executions
C10995 Number of successful 2G to 3G handovers
C10996 Number of 3G to 2G handover attempts
C10997 Number of 3G to 2G handover executions
C10998 Number of successful 3G to 2G handovers
C10999 Number of intra-cell handover attempts from TCH/F
C109100 Number of intra-cell TCH/F-to-TCH/F handover executions
C109101 Number of successful intra-cell TCH/F-to-TCH/F handovers
C109102 Number of intra-cell TCH/F-to-TCH/H handover executions
C109103 Number of successful intra-cell TCH/F-to-TCH/H handover
C109104 Number of intra-cell handover attempts from TCH/H
C109105 Number of intra-cell TCH/H-to-TCH/F handover executions
C109106 Number of successful intra-cell TCH/H-to-TCH/F handover
C109107 Number of intra-cell TCH/H-to-TCH/H handover executions
C109108 Number of successful intra-cell TCH/H-to-TCH/H handover
C109109 Number of inter-cell handover attempts times from TCH/F
C109110 Number of inter-cell TCH/F-to-TCH/F handover executions
C109111 Number of successful inter-cell TCH/F-to-TCH/F handovers
C109112 Number of inter-cell TCH/F-to-TCH/H handover executions
C109113 Number of successful inter-cell TCH/F-to-TCH/H handovers
C109114 Number of inter-cell handover attempts from TCH/H
C109115 Number of inter-cell TCH/H-to-TCH/F handover executions
C109116 Number of successful inter-cell TCH/H-to-TCH/F handovers
C109117 Number of inter-cell TCH/H-to-TCH/H handover executions
C109118 Number of successful inter-cell TCH/H-to-TCH/H handovers
C109119 Number of double-frequency external handover-out attempts
C109120 Number of double-frequency external handover-out executions
C109121 Number of successful double-frequency external handover outs
C109122 Number of double-frequency external handover in attempts
C109123 Number of double-frequency external handover in attempts
C109124 Number of successful double-frequency external handover ins

Confidential and Proprietary Information of ZTE CORPORATION 197


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Counter No. Counter Definition


C109125 Number of intra-cell invalid handovers
C109126 Intra-BSC handover-in forced release attempts
C109127 Intra-BSC handover-in executions (forced release)
C109128 Intra-BSC handover-in queue attempts
C109129 Intra-BSC handover-in executions (queue)

Handover Counters Explanation


C10901
Definition

Number of Intra-BSC inter-cell handover outs


Description

C10901 represents number of Intra-BSC inter-cell handover outs.


Initially MS in serving cell sends power measurement report to BTS of
serving cell. BTS of serving cell analyze the power measurement report,
makes its average and sends it to BSC of serving cell. BSC of serving
cell analyzes the power measurement report according to handover
algorithm and sends RADIO APPLY message to BSC of destination cell.
At this time, counter C10901 increments.
Measurement Point

Refer point A1 as shown in FIGURE 14.

FIGURE 14 - INTRA-BSC INTER-CELL HANDOVER MEASUREMENT

MS BTS:Ori_Cell BTS:Des_Cell BSC:Ori_Cell BSC:Des_Cell

Handover Algorithm
Measurement Report Measurement Report
RADIO APPLY

A1 A4
CHANNEL ACT

CHANNEL ACT ACK

RADIO AVAIL

A2 A5
HANDOVER COMMAND
HANDOVER COMMAND

HANDOVER COMPLETE HANDOVER COMPLETE

A6
HANDOVER COMPLETE
A3

198 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 11 - General Handover Measurement

C10902
Definition

Number of Intra-BSC inter-cell handover out executions


Description

C10902 represents number of actual Intra-BSC inter-cell handover


out executions. Initially BSC of serving cell analyzes power
measurement report according to handover algorithm and it sends
RADIO APPLY message to BSC of destination cell. Then the BSC of
destination cell checks radio resource availability and sends
CHANNEL ACT message to the BTS of destination cell. If BTS of
destination cell has radio channel available then it sends CHANNEL
ACT ACK message to BSC of destination cell. At last, BSC of
destination cell sends RADIO AVAIL message to BSC of serving cell.
C10902 increments if BSC of serving cell receive RADIO AVAIL
message from BSC of destination cell.
Measurement Point

Refer point A2, as shown in FIGURE 14.

C10903
Definition

Number of successful Intra-BSC inter-cell handover outs


Description

C10903 represents number of successful Intra-BSC inter-cell handover


outs. Initially BSC of serving cell sends HANDOVER COMMAND to BTS
of destination cell. Then BTS of serving cell sends HANDOVER
COMMAND to MS in serving cell. MS of serving cell sends HANDOVER
COMPLETE message to BTS of destination cell. BTS of destination cell
sends HANDOVER COMPLETE message to BSC of destination cell. BSC
of destination cell receives HANDOVER COMPLETE message at this,
C10903 increments.
Measurement Point

Counter C10903 makes statistics at point A3, as shown in FIGURE 14.

C10904
Definition

Number of Intra-MSC out going Handover attempts


Description

C10904 represents number of Intra-MSC handover-out attempts, when


BSC sends HANDOVER REQUIRED message to MSC.

Confidential and Proprietary Information of ZTE CORPORATION 199


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

FIGURE 15 - INTRA MSC HANDOVER SUCCESSES

MS BSC MSC

HANDOVER REQUIRED
A1

HANDOVER COMMAND HANDOVER COMMAND

A2
CLEAR COMMAND

A3

FIGURE 16 - INTRA MSC HANDOVER FAIL

BSC MSC

HANDOVER REQUIRED
A1
T7 TimeOut
HANDOVER REQUIRED REJECT

A2,B1,C1,D1

Measurement Point

C10904 makes statistics at point A1, as shown in FIGURE 15 and


FIGURE 16.

C10905
Definition

Number of Intra-MSC out going handover request failures due to


unclear causes
Description

C10905 represents number of Intra-MSC out going handover attempts


failure due to unknown causes. Initially BSC of serving cell sends
HANDOVER REQUIRED request to MSC. If timer T7 expires due to
unclear causes, the MSC sends HANDOVER REQUIRED REJECTED
command to the BSC of serving cell. BSC of serving cell receives
HANDOVER REQUIRED REJECTED message from MSC.
Measurement Point

Refer point A2 as shown in FIGURE 16.

200 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 11 - General Handover Measurement

C10906
Definition

Number of Intra-MSC out going handover requests failure due to


unavailability due to ground resource
Description

C10906 represents number of Intra-MSC out going handover attempts


failure due to unavailable ground resource in serving cell. Initially BSC
of serving cell sends HANDOVER REQUIRED request to MSC. Due to
unavailability of ground resource, MSC sends HANDOVER REQUIRED
REJECTED message to the BSC of serving cell. BSC of serving cell
receives HANDOVER REQUIRED REJECTED message from MSC. At this
time, MSC-controlled out going handover requests fail and C10906
increments.
Measurement Point

Refer point B1, as shown in FIGURE 16.

C10907
Definition

Number of Intra-MSC out going Handover requests failure due to


unavailability of wireless resource
Description

C10907 represents number of Intra-MSC out going handover attempts


failure due to unavailability of wireless resource. Initially BSC of
serving cell sends HANDOVER REQUIRED request to MSC. Due to
unavailability of wireless resource, MSC sends HANDOVER REQUIRED
REJECTED message to the BSC of serving cell. BSC of serving cell
receives HANDOVER REQUIRED REJECTED message from MSC. At this
time, MSC-controlled handover-out request fails and counter C10907
increments.
Measurement Point

Refer point C1, as shown in FIGURE 16.

C10908
Definition

Number of Intra-MSC out going handover requests failure due to other


causes
Description

C10908 represents number of Intra-MSC out going handover attempts


failure due to other causes. These other causes are other than the
above-mentioned causes. Initially BSC of serving cell sends HANDOVER

Confidential and Proprietary Information of ZTE CORPORATION 201


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

REQUIRED request to MSC. Due to other causes, MSC sends


HANDOVER REQUIRED REJECTED message to the BSC of serving cell.
BSC of serving cell receives HANDOVER REQUIRED REJECTED message
from MSC. At this time, MSC-controlled out going handover requests
fails and C10908 increments.
Measurement Point

Refer point D1, as shown in FIGURE 16.

C10909
Definition

Number of Intra-MSC out going handover executions


Description

C10909 represents number of Intra-MSC actual out going handover


executions. Initially BSC of serving cell sends HANDOVER REQUIRED
request to MSC. Then MSC sends HANDOVER COMMAND message to
BSC of serving cell. BSC sends HANDOVER COMMAND message to MS
of serving cell.
Measurement Point

Refer point A2, as shown in FIGURE 15

C10910
Definition
Number of successful Intra-MSC out going handovers
Description

C10910 represents number of Intra-MSC out going handover success.


Initially BSC of serving cell sends HANDOVER REQUIED message to
MSC. Then MSC sends HANDOVER COMMAND message to current BSC
as reply. BSC of serving cell sends HANDOVER COMMAND message to
MS in serving cell. After successful completion of handover, MSC sends
CLEAR command to BSC in serving cell. C10910 increments, when BSC
of serving cell receives CLEAR COMMAND message.
Measurement Point

Refer point A3 as shown in FIGURE 15.

C10911
Definition

Number of Intra-BSC Inter-cell handover in attempts


Description

C10911 represents number of successful Intra-BSC handover-ins


among Intra-BSC inter-cell handover. Initially MS of serving cell sends

202 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 11 - General Handover Measurement

power measurement report to BTS of serving cell. BTS of serving cell


makes average of power measurement and send this report to BSC of
serving cell. Here BSC of serving cell analyze power measurement
according to handover algorithm. If BSC of serving cell decides to
handover serving cell MS to destination cell, the BSC of serving cell
sends RADIO APPLY message to BSC of destination cell. C10911
increments, when BSC of destination cell receives RADIO APPLY
message.
Measurement Point

Refer point A4 as shown in FIGURE 14.

C10912
Definition

Number of Intra-BSC inter-cell handover in attempts


Description

C10912 represents number of Intra-BSC inter-cell handover executions


among Intra-BSC inter-cell handover. Initially BSC of serving cell
analyzes power measurement report according to handover algorithm
and it sends RADIO APPLY message to BSC of destination cell. Then
the BSC of destination cell checks radio resource availability and sends
CHANNEL ACT message to the BTS of destination cell. If BTS of
destination cell has radio channel available then it sends CHANNEL ACT
ACK message to BSC of destination cell. At last, BSC of destination cell
sends RADIO AVAIL message to BSC of serving cell.
Measurement Point

Refer point A5 as shown in FIGURE 14.

C10913
Definition
Number of successful Intra-BSC inter-cell handover ins
Description

C10913 represents number of handover-in success among Intra-BSC


inter-cell handover. Initially BSC of serving cell sends HANDOVER
COMMAND to BTS of destination cell. Then BTS of serving cell sends
HANDOVER COMMAND to MS in serving cell.
MS of serving cell sends HANDOVER COMPLETE message to BTS of
destination cell. BTS of destination cell sends HANDOVER COMPLETE
message to BSC of destination cell. BSC of destination cell receives
HANDOVER COMPLETE message and sends HANDOVER COMPLETE
message as reply to BSC of destination cell.
Measurement Point

Refer point A6 as shown in FIGURE 14.

Confidential and Proprietary Information of ZTE CORPORATION 203


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C10914
Definition

Number of Intra-MSC handover in attempts


Description

C10914 represents number of Intra-MSC external handover in


attempts. C10914 increments when BSC of serving cell receives
HANDOVER REQUEST message from MSC.
Measurement Point

Refer point A1 as shown in FIGURE 17.

FIGURE 17 - INTRA MSC HANDOVER IN

MS BSC MSC

HANDOVER REQUEST

A1,B1,C1,D1
HANDOVER REQUEST ACK
A2,D2,E2,F2
HANDOVER DETECT
HANDOVER COMPLETE
HANDOVER COMPLETE
A3,B3,C3

C10915
Definition

Number of MSC-controlled general handover-in execution


Description

C10915 represents number of Intra-MSC external handover-in


executions. C10915 increments when destination cell applies for
wireless resource successfully and sends HANDOVER REQUEST ACK
message to serving cell.
Measurement Point

Refer point A2 as shown in FIGURE 17.

C10916
Definition

Number of MSC-controlled handover-in attempt by forced-release

204 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 11 - General Handover Measurement

Description

C10916 represents number of MSC-controlled external handover-in by


forced release. C10916 increments when destination cell receives
HANDOVER REQUEST and BSC adopts forced release method to get
wireless resource.
Measurement Point

Refer point B1 in FIGURE 17.

C10917
Definition

Number of Intra-MSC handover in attempts by forced release


Description

C10917 represents number of Intra-MSC external handover in


attempts by forced release method. C10917 increments when
destination cell get wireless resource by forced release.
Measurement Point

Refer point D2 as shown in FIGURE 17.

C10918
Definition

Number of Intra-MSC handover in queue attempts


Description

C10918 represents number of queuing to get resource during Intra-


MSC external handover in. BSC makes queue due to unavailable
wireless resource. C10918 increments when destination cell receives
HANDOVER REQUEST message.
Measurement Point

Refer point C1 as shown in FIGURE 17.

C10919
Definition
Number of queuing executions during Intra-MSC handover in
Description
C10919 represents number of queuing executions during Intra-MSC
external handover in to get channel. C10919 increments when target
cell gets wireless resource after queuing. It then sends HANDOVER
REQUEST ACK to source cell.

Confidential and Proprietary Information of ZTE CORPORATION 205


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Measurement Point

Refer E2 as shown in FIGURE 17.

C10920
Definition

Number of successful Intra-MSC handover in


Description

C10920 represents number of successful Intra-MSC external handover


in. C10920 increments when destination cell receives HANDOVER
COMPLETE message.
Measurement Point

Refer point A3 as shown in FIGURE 17.

C10921
Definition

Total queue time during incoming Intra-MSC handover


Description

C10921 represents total time used for queuing during Intra-MSC


external handover in. Counter increments when BSC obtains wireless
resource successfully and queuing expires.
Measurement Point

Refer point D1 as shown in FIGURE 17.

C10922
Definition

Number of queues during Intra-MSC handover in


Description

C10922 represents number of resources obtained by queuing during


Intra-MSC external handover in.
Measurement Point

Refer point F2 in FIGURE 17.

C10923
Definition

Total successful queue during Intra-MSC handover in

206 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 11 - General Handover Measurement

Description

C10923 represents total time used for successful channel queuing


during Intra-MSC external handover in. C10923 increments when
destination cell receives HANDOVER COMPLETE message.
Measurement Point

Refer point B3 as shown in FIGURE 17.

C10924
Definition

Number of successful queues during Intra-MSC handover in


Description

C10924 represents number of successful handover when BSC obtains


wireless resources by queuing during Intra-MSC external handover-in.
Measurement Point

Refer point C3 as shown in FIGURE 17.

C10925
Definition

Number of handover in attempts from same layer and at the same


frequency
Description
C10925 represents number of handover in attempts from same layer
and at the same frequency during Intra-BSC inter-cell handover in cell.
Measurement Point

C10925 increments when destination cell receives RADIO APPLY


message.

C10926
Definition

Number of successful handover in from same layer and at the same


frequency
Description

C10926 represents number of handover in success from same layer


and same frequency during Intra-BSC inter-cell handover-in in cell.
Measurement Point

C10926 increments when destination cell receives HANDOVER


COMPLETE message.

Confidential and Proprietary Information of ZTE CORPORATION 207


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C10927
Definition

Number of handover out attempts to same layer and at the same


frequency
Description

C10927 represents number of handover-out attempt to same layer and


at the same frequency during Intra-BSC inter-cell handover-out in a
cell.
Measurement Point

C10927 increments when BSC receives measurement report.

C10928
Definition

Number of handover-out success to same layer and at the same


frequency

Description

Counter C10928 represents number of handover-out success to same


layer and at the same frequency during Intra-BSC inter-cell handover
out in a cell.
Measurement Point

C10928 increments when destination cell receives HANDOVER


COMPLETE message.

C10929
Definition

Number of handover in attempts from undefined layer and at the same


frequency
Description

C10929 represents number of handover in attempts from undefined


layer and at the same frequency during Intra-BSC inter-cell handover
in a cell.
Measurement Point

C1O929 increments when destination cell receives RADIO APPLY


message.

208 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 11 - General Handover Measurement

C10930
Definition

Number of successful handover in from undefined layer and at the


same frequency
Description

C10930 represents number of handover-in success from undefined


layer and same frequency during Intra-BSC inter-cell handover-in in a
cell.
Measurement Point

C10930 increments when destination cell receives HANDOVER


COMPLETE message.

C10931
Definition

Number of handover out attempts to undefined layer and at the same


frequency
Description

C10931 represents number of handover out attempts to undefined


layer and at the same frequency during Intra-BSC inter-cell handover
out in a cell.
Measurement Point

C10931 increments when BSC of serving cell receives measurement


report and it sends RADIO APPLY message to destination cell.

C10932
Definition

Number of successful handover out to undefined layer and at the same


frequency
Description

C10932 represents number of successful handover out to undefined


layer and at the same frequency during Intra-BSC inter-cell handover
out in a cell.
Measurement Point

Counter increments when destination cell receives HANDOVER


COMPLETE message

Confidential and Proprietary Information of ZTE CORPORATION 209


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C10933
Definition

Number of handover in attempts from undefined layer (GSM 900) to


current layer (GSM1800)
Description

C10933 represents number of handover in attempts from undefined


layer (GSM900) to current layer (GSM1800) during Intra-BSC inter-cell
handover in a cell.
Measurement Point

C10933 increments when destination cell receives RADIO APPLY


message.

C10934
Definition

Number of handover in attempts from undefined layer (GSM900) to


current layer (GSM1800)
Description

C10934 represents number of handover in attempts from undefined


layer (GSM900) to current layer (GSM1800) during Intra-BSC inter-cell
handover in a cell.
Measurement Point

C10934 increments when destination cell receives CHL ACTIVE ACK


message.

C10935
Definition

Number of successful handover in from undefined layer (GSM900) to


current layer (GSM1800)
Description

C10935 represents number of successful handover in from undefined


layer (GSM900) to current layer (GSM1800) during Intra-BSC inter-cell
handover in a cell.
Measurement Point

C10935 increments when destination cell receives HANDOVER


COMPLETE message.

210 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 11 - General Handover Measurement

C10936
Definition

Number of handover out attempts from GSM900 to undefined layer


(GSM 1800)
Description

C10936 Represents number of out going handover attempts from


GSM900 to undefined layer (GSM1800) during Intra-BSC inter-cell
handover-out in a cell.
Measurement Point

C10936 increments when BSC receives measurement report and it


sends RADIO APPLY message sends to destination cell.

C10937
Definition

Number of successful handover outs from GSM900 to undefined layer


(GSM1800)
Description

C10937 represents number of successful handover outs from GSM900


to undefined layer (GSM1800) during Intra-BSC inter-cell handover-out
in a cell.
Measurement Point

C10937 increments when serving cell receives HANDOVER COMPLETE


message.

C10938
Definition

Number of handover in attempts from undefined layer (GSM1800) to


current layer (GSM900)
Description

C10939 represents number of handover in attempts from undefined


layer (GSM1800) to current layer (GSM900) during Intra-BSC inter-cell
handover in a cell.
Measurement Point

Counter increments when destination cell receives RADIO APPLY


message.

Confidential and Proprietary Information of ZTE CORPORATION 211


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C10939
Definition

Number of handover in attempts from undefined layer (GSM1800) to


current layer (GSM900)
Description

C10939 represents number of handover in attempts from undefined


layer (GSM1800) to current layer (GSM900) during Intra-BSC inter-cell
handover in a cell.
Measurement Point

C10939 increments when destination cell receives CHL ACTIVE ACK


message.

C10940
Definition

Number of successful handover ins from undefined layer (GSM1800) to


current layer (GSM900)
Description

C10940 represents number of successful handover in successes from


undefined layer (GSM1800) to current layer (GSM900) during Intra-
BSC inter-cell handover in a cell.
Measurement Point

C10940 increments when target cell receives HANDOVER COMPLETE


message.

C10941
Definition

Number of handover out attempts from GSM1800 to undefined layer


(GSM900)
Description

C10941 represents number of handover out attempts from GSM1800


to undefined layer (GSM900) during Intra-BSC inter-cell handover out
in a cell.
Measurement Point

C10941 increments when BSC receives measurement report and it


sends RADIO APPLY message to destination cell.

212 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 11 - General Handover Measurement

C10942
Definition

Number of successful handover out success from GSM1800 to


undefined layer (GSM1800)
Description

C10942 represents number of successful handover outs from GSM1800


to undefined layer (GSM900) during Intra-BSC inter-cell handover out
in a cell.
Measurement Point

C10942 increments when serving cell receives HANDOVER COMPLETE


message.

C10943
Definition

Number of handover-in attempts from upper layer and at the same


frequency
Description

C10943 represents number of handover in attempts from upper layer


and at the same frequency during Intra-BSC inter-cell handover in a
cell.
Measurement Point

C10943 increments when destination cell receives RADIO APPLY


message.

C10944
Definition

Number of successful handover in success from upper layer and at the


same frequency
Description

C10944 represents number of successful handover in from upper layer


and at the same frequency during Intra-BSC inter-cell handover in a
cell.
Measurement Point

C10944 increments when destination cell receives HANDOVER


COMPLETE message.

Confidential and Proprietary Information of ZTE CORPORATION 213


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C10945
Definition

Number of handover out attempts to upper layer and same frequency


Description

C10945 represents number of handover out attempts to upper layer


and at the same frequency during Intra-BSC inter-cell handover-out in
a cell.
Measurement Point

C10945 makes statistics when BSC receives measurement report and


it sends RADIO APPLY message to target cell.

C10946
Definition

Number of successful handover out to upper layer and at the same


frequency
Description

C10946 represents number of successful handover outs to upper layer


and at the same frequency during Intra-BSC inter-cell handover-out in
a cell.
Measurement Point

C10946 increments when source cell receives HANDOVER COMPLETE


message.

C10947
Definition

Number of handover in attempts from lower layer and at the same


frequency
Description
C10947 represents number of handover in attempts from the lower
layer and at the same frequency during Intra-BSC inter-cell handover
in a cell.
Measurement Point

C10947 increments when destination cell receives RADIO APPLY


message.

C10948
Definition

Number of successful handover in successes from lower layer and at


the same frequency

214 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 11 - General Handover Measurement

Description

C10948 represents number of successful handover in from lower layer


and at the same frequency during Intra-BSC inter-cell handover in a
cell.
Measurement Point

C10948 increments when destination cell receives HANDOVER


COMPLETE message.

C10949
Definition

Number of handover out attempts to lower layer and at the same


frequency
Description

C10949 represents number of handover out attempts to lower layer


and at the same frequency during Intra-BSC inter-cell handover-out in
a cell.
Measurement Point

C10949 increments when BSC receives measurement report and sends


RADIO APPLY message to destination cell.

C10950
Definition

Number of successful handover out to lower layer and at the same


frequency
Description

C10950 represents number of successful handover out to lower layer and


at the same frequency during Intra-BSC inter-cell handover out in a cell.

Measurement Point

Counter C10950 increments when source cell receives HANDOVER


COMPLETE message.

C10951
Definition

Number of handover in attempts from same layer and from GSM900 to


GSM1800
Description

C10951 represents number of handover in attempts at same layer and


from GSM900 to GSM1800 during Intra-BSC inter-cell handover in a
cell.

Confidential and Proprietary Information of ZTE CORPORATION 215


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Measurement Point

C10951 increments when destination cell receives RADIO APPLY


message.

C10952
Definition

Number of handover in attempts at same layer and from GSM900 to


GSM1800
Description

C10952 represents number of handover in attempts from same layer


and from GSM900 to GSM1800 during Intra-BSC inter-cell handover in
a cell.
Measurement Point

C10953 increments when target cell receives CHL ACTIVE ACK


message.

C10953
Definition

Number of successful handover in at same layer and from GSM900 to


GSM1800 MHz
Description

C10953 represents number of successful handover in of the same layer


and from GSM900 to GSM1800 during Intra-BSC inter-cell handover in
a cell.
Measurement Point

C10954 increments when destination cell receives HANDOVER


COMPLETE message.

C10954
Definition

Number of handover out attempts to same layer and from GSM900 to


GSM1800
Description

C10954 represents number of handover out attempts to same layer


and from GSM900 to GSM1800 during Intra-BSC inter-cell handover-
out in a cell.

216 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 11 - General Handover Measurement

Measurement Point

C10954 increments when BSC receives measurements report,


handover decision occurs and RADIO APPLY message is sent to
destination cell.

C10955
Definition

Number of successful handover out to same layer and from GSM900 to


GSM1800
Description

C10955 represents number of successful handover out to same layer


and from GSM900 to GSM1800 during Intra-BSC inter-cell handover-
out in a cell.
Measurement Point

Counter C10955 increments when serving cell receives HANDOVER


COMPLETE message.

C10956
Definition

Number of handover in attempts from upper layer and from GSM900 to


GSM1800
Description

C10956 represents number of handover in attempts from upper layer


and from GSM900 to GSM1800 during Intra-BSC inter-cell handover in
a cell.
Measurement Point

Counter C10956 increments when destination cell receives RADIO


APPLY message.

C10957
Definition

Number of handover in attempts from upper layer and from GSM900 to


GSM1800
Description

C10957 represents number of handover in attempts from upper layer


and from GSM900 to GSM1800 during Intra-BSC inter-cell handover in
at the cell.

Confidential and Proprietary Information of ZTE CORPORATION 217


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Measurement Point

Counter C10957 increments when source cell receives CHL ACTIVE


ACK message.

C10958
Definition

Number of handover in successes from upper layer and from GSM900


to GSM1800
Description

C10958 represents number of successful handover in from upper layer


and from GSM900 to GSM1800 during Intra-BSC inter-cell handover in
a cell.
Measurement Point

C10958 increments when destination cell receives HANDOVER


COMPLETE message.

C10959
Definition

Number of handover out attempts to upper layer and form GSM900 to


GSM1800
Description

C10959 represents number of handover out attempts to upper layer


and (from GSM900 to GSM1800during Intra-BSC inter-cell handover
out in a cell.
Measurement Point

C10960 increments when BSC receives measurement report and it


sends RADIO APPLY message to destination cell.

C10960
Definition

Number of successful handover out to upper layer and from GSM900 to


GSM1800
Description

C10960 represents number of successful handover out to upper layer


and from GSM900 to GSM1800 during Intra-BSC inter-cell handover
out in a cell.
Measurement Point

C10960 increments when source cell receives HANDOVER COMPLETE


message.

218 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 11 - General Handover Measurement

C10961
Definition

Number of handover in attempts from lower layer and from GSM900 to


GSM1800
Description

C10961 represents number of handover in attempts from lower layer


and from GSM900 to GSM1800 during Intra-BSC inter-cell handover in
at a cell.
Measurement Point

C10961 increments when destination cell receives RADIO APPLY


message.

C10962
Definition

Number of handover in attempts from lower layer and from GSM900 to


GSM1800
Description

C10962 represents number of handover in attempts from lower layer


and from GSM900 to GSM1800 during Intra-BSC inter-cell handover in
at a cell.
Measurement Point

C10963 increments when destination cell receives CHL ACTIVE ACK


message.

C10963
Definition

Number of handover-in successes from lower layer and from GSM900


to GSM1800
Description

C10963 represents number of successful handover in from lower layer


and from GSM900 to GSM1800 during Intra-BSC inter-cell handover in
at cell.
Measurement Point

C10963 increments when target cell receives HANDOVER COMPLETE


message.

Confidential and Proprietary Information of ZTE CORPORATION 219


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C10964
Definition

Number of handover out attempts to lower layer and from GSM900 to


GSM1800
Description

C10964 represents number of handover out attempts to lower layer


and from GSM900 to GSM1800 during Intra-BSC inter-cell handover
out in a cell.
Measurement Point

C10964 increments when BSC receives measurement report and it


sends RADIO APPLY message to target cell.

C10965
Definition

Number of successful handover outs to lower layer and from GSM900


to GSM1800
Description

C10965 represents number of handover out to lower layer and from


GSM900 to GSM1800 during Intra-BSC inter-cell handover out in a cell.
Measurement Point

C10965 increments when serving cell receives HANDOVER COMPLETE


message

C10966
Definition

Number of handover in attempts from same layer and from GSM1800


to GSM900
Description

C10966 represents number of handover in attempts from same layer


and from GSM1800 to GSM900 during Intra-BSC inter-cell handover in
at a cell.
Measurement Point

C10966 increments when destination cell receives RADIO APPLY


message.

220 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 11 - General Handover Measurement

C10967
Definition

Number of handover in attempts from same layer and from GSM1800


to GSM900
Description

C10967 represents number of handover in attempts from same layer


and from GSM1800 to GSM900 during Intra-BSC inter-cell handover in
at a cell.
Measurement Point

Counter C10967 increments when destination cell receives CHL ACTIVE


ACK message.

C10968
Definition;

Number of successful handover in from same layer and from GSM1800


to GSM900
Description

C10968 represents number of successful handover in from same layer


and from GSM1800 to GSM900 during Intra-BSC inter-cell handover in
at a cell.
Measurement Point

Counter C10968 increments when the target cell receives HANDOVER


COMPLETE message.

C10969
Definition

Number of handover out attempts to same layer and from GSM1800 to


GSM900
Description

C10969 represents number of handover attempts to same layer and


from GSM1800 to GSM900 during Intra-BSC inter-cell handover out in
a cell.
Measurement Point

C10969 increments when BSC receives measurement report and it


sends RADIO APPLY message to destination cell.

Confidential and Proprietary Information of ZTE CORPORATION 221


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C10970
Definition

Number of successful handover outs to same layer and from GSM1800


to GSM900
Description

C10970 represents number of successful handover to same layer and


from GSM1800 to GSM900 during Intra-BSC inter-cell handover out in
a cell.
Measurement Point

C10970 increments when destination cell receives HANDOVER


COMPLETE message.

C10971
Definition

Number of handover in attempts from upper layer and from GSM1800


to GSM900
Description

C10971 represents number of handover in attempts from upper layer


and from GSM1800 to GSM900 during Intra-BSC inter-cell handover in
at a cell.
Measurement Point

C10971 increments when destination cell receives RADIO APPLY


message.

C10972
Definition

Number of handover in attempts from upper layer and from GSM1800


to GSM900
Description

C10972 represents number of handover in attempts from upper layer


and from GSM1800 to GSM900 during Intra-BSC inter-cell handover in
at a cell.
Measurement Point

Counter C10972 increments when destination cell receives CHL ACTIVE


ACK message.

222 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 11 - General Handover Measurement

C10973
Definition

Number of successful handover in successes from upper layer and from


GSM1800 to GSM900
Description

C10973 represents number of successful handover in from upper layer


and from GSM1800 to GSM900 during Intra-BSC inter-cell handover in
at a cell.
Measurement Point

C10973 increments when destination cell receives HANDOVER


COMPLETE message.

C10974
Definition

Number of handover out attempts to upper layer from GSM1800 to


GSM900
Description

C10974 represents number of handover-out attempts to upper layer


and from GSM1800 to GSM900 during Intra-BSC inter-cell handover-
out in a cell.
Measurement Point

C10974 increments when BSC receives measurement report and it


sends RADIO APPLY message to destination cell.

C10975
Definition

Number of successful handover outs to upper layer and from GSM1800


to GSM900
Description

C10975 represents number o number of successful handover outs to


upper layer and from GSM1800 to GSM900 during Intra-BSC inter-cell
handover out in a cell.
Measurement Point

C10975 increments when serving cell receives HANDOVER COMPLETE


message.

Confidential and Proprietary Information of ZTE CORPORATION 223


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C10976
Definition

Number of handover in attempts from lower layer and from GSM1800


to GSM900
Description

C10976 represents number of handover in attempts from lower layer


and from GSM1800 to GSM900 during Intra-BSC inter-cell handover-in
at a cell.
Measurement Point

C10976 increments when destination cell receives RADIO APPLY


message.

C10977
Definition

Number of handover in attempts from lower layer and from GSM1800


to GSM900
Description

C10977 represents number of handover in attempts from lower layer


and from GSM1800 to GSM900 during Intra-BSC inter-cell handover in
at a cell.
Measurement Point

C10977 increments when destination cell receives CHL ACTIVE ACK


message.

C10978
Definition

Number of successful handover ins from lower layer and from


GSM1800 to GSM900
Description

C10978 represents number of successful handover in from lower layer


and from GSM1800 to GSM900 during Intra-BSC inter-cell handover in
at a cell.
Measurement Point

C10978 increments when destination cell receives HANDOVER


COMPLETE message.

224 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 11 - General Handover Measurement

C10979
Definition

Number of handover out attempts to lower layer and from GSM1800 to


GSM900
Description

C10979 represents number of handover out attempts to lower layer


and from GSM1800 to GSM900 during Intra-BSC inter-cell handover
out in a cell.
Measurement Point

C10979 increments when BSC receives measurement report and it


sends RADIO APPLY message to destination cell.

C10980
Definition

Number of successful handover out-out to lower layer and from


GSM1800 to GSM900
Description

C1090 represents number of successful handover out to lower layer


and from GSM1800 to GSM900 during Intra-BSC inter-cell handover
out in a cell.
Measurement Point

C10980 increments when source cell receives HANDOVER COMPLETE


message.

C10981
Definition

Number of Intra-cell handover attempts


Description

When an origination channel requires internal handover, it sends


measurements report to BSC. BSC analyzes measurement report,
according to handover algorithm. After handover analysis, the BSC
decides whether internal handover is required or not. If internal
handover is required, BSC sends RADIO APPLY message to destination
channel.
Measurement Point

C10981 increments when BSC receives measurement report and it


sends RADIO APPLY message to destination channel.

Confidential and Proprietary Information of ZTE CORPORATION 225


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C10982
Definition

Number of successful intra-cell handovers


Description

C10982 represents number of successful intra-cell handovers.


Measurement Point

C10982 increments when origination channel receives ASSIGN


COMPLETE message.

C10983
Definition

Number of intra-cell and inner-circle-to-outer-circle handover attempts


Description

C10983 represents number of intra-cell and inner-circle-to-outer-circle


handover attempts during intra-cell handover in a concentric circle cell.
For the non-concentric circle cell, following counters related with
concentric circle cell is same as intra-cell handover counters.
Measurement Point

C10984 increments when BSC receives measurement report and the


BSC sends RADIO APPLY message to destination cell.

C10984
Definition

Number of time of successful intra-cell and inner-circle-to-outer-circle


handover
Description

C10984 represents number of successful intra-cell and inner-circle-to-


outer-circle handovers during intra-cell handover in a concentric circle
cell.
Measurement Point

C10984 increments when serving cell receives ASSIGN COMPLETE


message.

C10985
Definition

Number of intra-cell and outer-circle-to-inner-circle handover attempts

226 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 11 - General Handover Measurement

Description

C10985 represents number of intra-cell and outer-circle-to-inner-circle


handover attempts during intra-cell handover in a concentric circle cell.
Measurement Point

C10985 increments when BSC receives measurement report and it


sends RADIO APPLY message to destination cell.

C10986
Definition

Number of successful intra-cell and outer-circle-to-inner-circle


handovers
Description

C10987 represents number of intra-cell and outer-circle-to-inner-circle


handover attempts during intra-cell handover in a concentric circle cell.
Measurement Point

C10987 increments when destination cell receives ASSIGN COMPLETE


message.

C10987
Definition

Number of intra-cell and inner-circle-to-inner-circle handover attempts


Description

C1987 represents number of intra-cell and inner-circle-to-inner-circle


handover attempts during intra-cell handover in a concentric circle cell.
Measurement Point

C10987 increments when BSC receives measurement report and BSC


sends RADIO APPLY message to destination cell.

C10988
Definition

Number of successful intra-cell and inner-circle-to-inner-circle


handovers
Description

C10988 represents number of successful intra-cell and inner-circle-to-


inner-circle handovers during intra-cell handover in a concentric circle
cell.

Confidential and Proprietary Information of ZTE CORPORATION 227


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Measurement Point

C10988 increments when serving cell receives ASSIGN COMPLETE


message

C10989
Definition

Number of Intra-cell and outer-circle-to-outer-circle handover attempts


Description

C10989 represents number of intra-cell and outer-circle-to-outer-circle


handover attempts during intra-cell handover in a concentric circle cell.
Measurement Point

C10989 increments when BSC receives measurement report and it


sends RADIO APPLY message to destination cell.

C10990
Definition

Number of successful intra-cell and outer-circle-to-outer-circle


handovers
Description

C1090 represents number of intra-cell and outer-circle-to-outer-circle


handover attempts during intra-cell handover in a concentric circle cell.
Measurement Point

C10991 increments when serving cell receives ASSIGN COMPLETE


message.

C10991
Definition

Number of handover out executions from GSM1800 to GSM900


Description

C10991 represents number of handover out executions from GSM1800


to GSM900 during Intra-BSC inter-cell handover out in a cell.
Measurement Point

C10991 increments when BSC receives RADIO AVAIL message from


destination cell.

228 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 11 - General Handover Measurement

C10992
Definition

Number of handover out executions from GSM900 to GSM1800


Description

C10992 represents number of handover executions from GSM900 to


GSM1800 during Intra-BSC inter-cell outgoing handover in a cell.
Measurement Point

C10992 increments when BSC receives RADIO AVAIL message from


destination cell.

C10993
Definition

Number of 2G to 3G handover attempts


Description
C10993 represents number of GSM-to-UTRAN handover attempts.
Measurement Point

C10993 increments when BSC judges requirement of GSM cell to


UTRAN cell handover and BSC of GSM system sends HANDOVER
REQUIRED message to BSC of UTRAN system.

C10994
Definition

Number of 2G to 3G handover executions


Description

C10994 represents number of GSM-to-UTRAN handover executions.


Measurement Point

C10994 increments when BSC receives HANDOVER COMMAND


message from UTRAN. It then forwards it to MS.

C10995
Definition

Number of successful 2G to 3G handovers


Description

C10995 represents number of successful GSM-to-UTRAN handovers.

Confidential and Proprietary Information of ZTE CORPORATION 229


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Measurement Point

C10995 increments when BSC of GSM system receives CLEAR


COMMAND.

C10996
Definition

Number of 3G to 2G handover attempts


Description

C10996 represents number of UTRAN-to-GSM handover attempts


Measurement Point

C10996 increments when destination cell receives RADIO APPLY


message.

C10997
Definition

Number of 3G to 2G handover executions


Description

C10997 represents number of UTRAN-to-GSM handover executions


Measurement Point

C10997 increments when destination cell receives CHL ACTIVE ACK


message.

C10998
Definition

Number of successful 3G to 2G handovers


Description

C10998 represents number of successful UTRAN-to-GSM handovers


Measurement Point

C10998 increments when destination cell receives HANDOVER


COMPLETE message.

C10999
Definition

Number of intra-cell handover attempts from TCH/F

230 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 11 - General Handover Measurement

Description

This index provides statistics for handover out attempts from TCH/F
channel at intra-cell handover.
Measurement Point

C10999 increments when destination cell receives RADIO APPLY


message.

C109100
Definition

Number of intra-cell and TCH/F-to-TCH/F handover executions


Description

C109100 represents number of handover-out executions from TCH/F


channel to TCH/F channel during intra-cell handover.
Measurement Point

C109100 increments when destination cell receives CHL ACTIVE ACK


message.

C109101
Definition

Number of successful intra-cell and TCH/F-to-TCH/F handovers


Description

Counter C109101 represents number of successful handover out from


TCH/F channel to TCH/F channel during intra-cell handover.
Measurement Point

C109101 increments when destination cell receives ASSIGN COMPLETE


message.

C109102
Definition

Number of intra-cell and TCH/F-to-TCH/H handover executions


Description

C109102 represents number of handover out executions from TCH/F


channel to TCH/H during intra-cell handover.
Measurement Point

C109102 increments when destination cell receives CHL ACTIVE ACK


message.

Confidential and Proprietary Information of ZTE CORPORATION 231


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C109103
Definition

Number of successful intra-cell and TCH/F-to-TCH/H


Description

r C109103 represents number of successful handover out from TCH/F


channel to TCH/H during intra-cell handover.
Measurement Point

C109103 increments when destination cell receives ASSIGN COMPLETE


message.

C109104
Definition

Number of intra-cell handover attempts from TCH/H


Description
C109104 represents number of handover out attempts from TCH/H
during intra-cell handover.
Measurement Point

C109104 increments when destination cell receives RADIO APPLY


message.

C109105
Definition

Number of intra-cell handover executions from TCH/H-to-TCH/F


Description

C109106 represents number of handover out executions from TCH/H


to TCH/F channel during intra-cell handover.
Measurement Point

C109106 increments when destination cell receives CHL ACTIVE ACK


message.

C109106
Definition

Number of successful intra-cell handovers from TCH/H-to-TCH/F


Description

C109106 represents number of successful handover out from TCH/H to


TCH/F channel during intra-cell handover.

232 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 11 - General Handover Measurement

Measurement Point

C109106 increments when destination cell receives ASSIGN COMPLETE


message.

C109107
Definition

Number of intra-cell handover executions from TCH/H-to-TCH/H


Description

C109107 represents number of handover out executions from TCH/H


to TCH/H during intra-cell handover.
Measurement Point

C109107 increments when destination cell receives CHL ACTIVE ACK


message.

C109108
Definition

Number of successful intra-cell handovers from TCH/H-to-TCH/H


Description

C109109 represents number of successful handover out from the


TCH/H to TCH/H at intra-cell handover.
Measurement Point

C109109 increments when destination cell receives ASSIGN COMPLETE


message.

C109109
Definition

Number of inter-cell handover attempts from TCH/F


Description

C109109 represents number of handover out attempts from TCH/F


channel during Intra-BSC inter-cell handover.
Measurement Point

C109109 increments when destination cell receives RADIO APPLY


message.

C109110
Definition

Number of inter-cell handover executions from TCH/F-to-TCH/F

Confidential and Proprietary Information of ZTE CORPORATION 233


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Description

C109110 represents number of handover out executions from TCH/F


channel to TCH/F channel during Intra-BSC inter-cell handover.
Measurement Point

C109110 increments when destination cell receives CHL ACTIVE ACK


message.

C109111
Definition

Number of successful inter-cell handover from TCH/F-to-TCH/F


Description

C109111 represents number of successful handover out from TCH/F


channel to TCH/F channel during Intra-BSC inter-cell handover.
Measurement Point

C109111 increments when destination cell receives ASSIGN COMPLETE


message.

C109112
Definition

Number of inter-cell handover executions from TCH/F-to-TCH/H


Description

C10912 represents number of handover out executions from TCH/F


channel to TCH/H during Intra-BSC inter-cell handover.
Measurement Point

C109112 increments when destination cell receives CHL ACTIVE ACK


message.

C109113
Definition

Number of successful inter-cell handovers from TCH/F-to-TCH/H


Description

C109113 represents number of successful handover out from TCH/F


channel to TCH/H during Intra-BSC inter-cell handover.
Measurement Point

C109113 increments when destination cell receives ASSIGN COMPLETE


message.

234 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 11 - General Handover Measurement

C109114
Definition

Number of inter-cell handover attempts from TCH/H


Description
C109113 represents number of handover out attempts from TCH/H
during Intra-BSC inter-cell handover.
Measurement Point

C109114 increments when destination cell receives RADIO APPLY


message.

C109115
Definition

Number of inter-cell handover executions from TCH/H-to-TCH/F


Description

C109115 represents number of handover out executions from TCH/H


to TCH/F channel during Intra-BSC inter-cell handover.
Measurement Point

C109115 increments when destination cell receives CHL ACTIVE ACK


message.

C109116
Definition

Number of successful inter-cell handovers from TCH/H-to-TCH/F


Description

C109116 represents number of successful handover out from TCH/H to


TCH/F channel during Intra-BSC inter-cell handover.
Measurement Point

C109116 increments when destination cell receives ASSIGN COMPLETE


message

C109117
Definition

Number of inter-cell handover executions from TCH/H-to-TCH/H


Description

C109117 represents number of handover out executions from TCH/H


to TCH/H during Intra-BSC inter-cell handover.

Confidential and Proprietary Information of ZTE CORPORATION 235


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Measurement Point

Counter increments when destination cell receives CHL ACTIVE ACK


message.

C109118
Definition

Number of successful inter-cell handovers from TCH/H-to-TCH/H


Description

C109118 represents number of successful handover out from TCH/H to


TCH/H during Intra-BSC inter-cell handover.
Measurement Point

C109118 increments when destination cell receives ASSIGN COMPLETE


message.

C109119
Definition

Number of double-frequency external handover out attempts


Description

C10919 represents number of handover attempts from serving cell


band to destination cell different band during Intra-MSC external
handover.
Measurement Point

C109110 increments when serving BSC sends HANDOVER REQUIRED


message to destination cell upon receiving MS measurement report.

C109120
Definition

Number of double-frequency external handover out executions


Description

C109120 represents number of handover out executions between


serving cell band and different destination cell band during Intra-MSC
external handover.
Measurement Point

C109120 increments when BSC receives HANDOVER COMMAND


message from A-interface and it sends HANDOVER COMMAND message
to MS.

236 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 11 - General Handover Measurement

C109121
Definition

Number of successful double-frequency external handover outs


Description

C109121 represents number of successful handovers between serving


cell band and different destination cell band during Intra-MSC external
handover.
Measurement Point

C109121 increments when BSC receives CLEAR COMMAND message


from A-interface.

C109122
Definition

Number of double-frequency external handover-in attempts


Description

C109122 represents number of handover attempts between serving


cell bands different from destination cell band during Intra-MSC
external handover-in.
Measurement Point

C109123 increments when destination cell receives HANDOVER


REQUEST message from A-interface.

C109123
Definition

Number of double-frequency external handover in attempts


Description

C109123 represents number of handover executions between serving


cell band and different destination cell band during Intra-MSC external
handover-in.
Measurement Point
C109123 increments when destination cell receives CHL ACTIVE ACK
message.

C109124
Definition

Number of successful double-frequency external handover ins

Confidential and Proprietary Information of ZTE CORPORATION 237


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Description

C109124 represents number of successful handovers between serving


cell band and different destination cell band during Intra-MSC external
handover in.
Measurement Point

C109124 increments when destination cell receives HANDOVER


COMPLETE message.

C109125
Definition

Number of intra-cell invalid handovers


Description

C109125 represents number of invalid handover. During intra-cell


handover, due to uplink or down link interference an MS get a new
channel in a new cell. Again if there is uplink and downlink interference
occur in new cell MS want to do another handover from recently
resided cell. At this time, BSC prohibits the MS from handover due to
invalid handover.
Measurement Point

C109125 increments when an MS requires intra-cell handover due to


same uplink or downlink interference.

C109126
Definition

Intra-BSC handover-in forced release attempts


Description

During the intra-BSC inter-cell handover-in or intra-BSC intra-cell


handover, this index is used to count the number of obtaining resource
by forced release method when no wireless channels are available,
which helps to provide frequency information of the forced release of
the serving cell which is implemented during intra-BSC inter-cell
handover-in or intra-BSC intra-cell handover in the serving cell.
Measurement Point

The object cell (the serving cell) has received RADIO APPLY; the
application cause is the inter-cell or intra-cell handover. Counter
increments when the forced release is implemented to obtain resource.

238 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 11 - General Handover Measurement

C109127
Definition

Intra-BSC handover-in executions (forced release)


Description

During the intra-BSC inter-cell handover-in or intra-BSC intra-cell


handover, this index is used to count the number of channel handover
by forced release method, which helps to provide frequency
information of channel handover by forced release during the inter-BSC
inter-cell or inter-BSC intra-cell handover in the serving cell.
Measurement Point

The object cell (the serving cell) has received RADIO APPLY; the
application cause is the inter-cell or intra-cell handover. Counter
increments when the forced release is implemented to obtain resource.

C109128
Definition

Intra-BSC handover-in queue attempts


Description

During the intra-BSC inter-cell handover-in or intra-BSC intra-cell


handover, this index is used to count the number of queuing for
resource when no wireless channels are available, which helps to
provide frequency information of the queuing which is implemented
during intra-BSC inter-cell handover-in or intra-BSC intra-cell handover
in the serving cell.
Measurement Point

The object cell (the serving cell) has received RADIO APPLY; the
application cause is the inter-cell or intra-cell handover. Counter
increments when the queuing for resource is implemented.

C109129
Definition

Intra-BSC handover-in executions (queue)

Description

During the intra-BSC inter-cell handover-in or intra-BSC intra-cell


handover, this index is used to count the number of getting the
resource after queuing when no wireless channels are available, which
helps to provide frequency information of getting the resource after
queuing which is implemented during intra-BSC inter-cell handover-in
or intra-BSC intra-cell handover in the serving cell.

Confidential and Proprietary Information of ZTE CORPORATION 239


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Measurement Point

The object cell (the serving cell) has received RADIO APPLY; the
application cause is the inter-cell or intra-cell handover. Counter
increments when the resource is got after queuing.

240 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 12

Synchronization Mode
Handover Measurement

This chapter covers the following topics:

Synchronization Mode Handover Counters

Synchronization Mode Counters


These counters provide statistics for Synchronization Mode handovers.
Synchronization mode includes Synchronized, non-synchronized, pseudo,
asynchronous and pre-synchronous handovers. For Synchronized
handovers it requires that the clock of all involving cells should finely
synchronize.

Table 20 lists all the Synchronized handover counters.

TABLE 20 SYNCHRONIZED HANDOVER COUNTERS

Counter No. Counter Definition


C11201 Number of synchronous handover executions
C11202 Number of successful synchronous handovers
C11203 Number of pre-synchronous handover executions
C11204 Number of successful pre-synchronous handovers
C11205 Number of pseudo-synchronous handover executions
C11206 Number of successful pseudo-synchronous handovers
C11207 Number of asynchronous handover executions
C11208 Number of successful asynchronous handovers

Confidential and Proprietary Information of ZTE CORPORATION 241


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Synchronization Mode Counters


Explanation
C11201
Definition

Number of synchronous handover executions


Description

C11201 represents number of handover executions in synchronous


handover mode. In this scenario there are Intra-MSC external
handover in and Intra-BSC inter-cell handover. Channel activation
cause is synchronous handover mode.
Measurement Point

C11201 increments when serving cell receive CHLACTIVE ACK message.

C11202
Definition

Number of successful synchronous handovers


Description

C11202 represents number of successful synchronous handover. In


this scenario there are intra-cell handover, Intra-MSC external
handover in and Intra-BSC inter-cell handover.
Measurement Point

C11202 increments when serving cell receives ASSIGN COMPLETE


message during intra-cell synchronous handover. Similarly C11202
increments when serving cell receive HANDOVER COMPLETE message
during Intra-MSC external cell handover or Intra-BSC inter-cell
synchronous handover.

C11203
Definition

Number of pre-synchronous handover executions


Description

C11203 represents number of handover executions in pre-synchronous


handover mode. In this scenario there are Intra-MSC external
handover in and Intra-BSC inter-cell handover. Channel activation
cause is pre-synchronous handover mode.

242 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 12 - Synchronization Mode Handover Measurement

Measurement Point

C11203 increments when serving cell receives CHL ACTIVE ACK


message during Intra-MSC external handover in or Intra-BSC inter-cell
handover.

C11204
Definition

Number of successful pre-synchronous handovers


Description

C11204 represents number of successful pre-synchronous handovers.


In this scenario there are Intra-MSC external handover in and Intra-
BSC inter-cell handover.
Measurement Point

C11204 increments when serving cell receives HANDOVER COMPLETE


message during Intra-MSC external handover or Intra-BSC inter-cell
handover.

C11205
Definition

Number of pseudo-synchronous handover executions


Description

C11205 represents number of pseudo-synchronous handover


executions. In this scenario there are Intra-MSC external handover in
and Intra-BSC inter-cell handover. Channel activation cause is
synchronous handover mode.
Measurement Point

C11205 increments when serving cell receives CHL ACTIVE ACK message
during Intra-MSC external handover in or Intra-BSC inter-cell handover.

C11206
Definition

Number of successful pseudo-synchronous handovers


Description

C11206 represents number of successful pseudo-synchronous


handovers. In this scenario there are Intra-MSC external handover in
and Intra-BSC inter-cell handover.
Measurement Point

Confidential and Proprietary Information of ZTE CORPORATION 243


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C11206 increments when serving cell receives HANDOVER COMPLETE


message during Intra-MSC external handover of Intra-BSC inter-cell
handover.

C11207
Definition

Number of asynchronous handover executions


Description

C11207 represents number of asynchronous handover executions. In


this scenario there are Intra-MSC external handover in and Intra-BSC
inter-cell handover.
Measurement Point

C11207 increments when serving cell receives CHL ACTIVE ACK


message during Intra-MSC external handover in or Intra-BSC inter-cell
handover.

C11208
Definition

Number of successful asynchronous handovers


Description

C11208 represents number of successful asynchronous handover. In


this scenario there are Intra-MSC external handover in and Intra-BSC
inter-cell handover.
Measurement Point

C11208 increments when serving cell receives HANDOVER COMPLETE


message during Intra-MSC external handover in of Intra-BSC inter-cell
handover.

244 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 13

Paging Message
Measurement

This chapter covers the following topics:

Paging Message Counter

Paging Message Counter


Table 21 defines paging measurement counter.

TABLE 21 PAGING MESSAGE COUNTER

Counter No. Counter Definition


C11301 Number of sent paging message

C11301
Definition

Number of sent paging message


Description

C11301 provide statistics for number paging messages send to each


relevant cell after BSC receives the paging command from A-interface.
Measurement Point

C11301 increments when BSC sends PAGING COMMAND to the


relevant cell.

Confidential and Proprietary Information of ZTE CORPORATION 245


This page is intentionally blank

246 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 14

Abis-Interface Signaling

This chapter covers the following topics:

Abis-interface Measurement

Abis-interface Measurement
Abis-interface Measurement includes counters that provide signaling
statistics of Abis-interface. These counters keep the statistics of all the
messages that BSC receives or send on the Abis-interface.

Abis-interface Counters
Table 22 lists all the Abis-interface message counters.

TABLE 22 ABIS-INTERFACE MESSAGE COUNTERS

Counter No. Counter Definition


C11401 Number of DATA REQUEST messages
C11402 Number of DATA INDICATION messages
C11403 Number of ERROR INDICATION messages
C11404 Number of ESTABLISH REQUEST messages
C11405 Number of ESTABLISH CONFIRM messages
C11406 Number of ESTABLISH INDICATION messages
C11407 Number of RELEASE REQUEST messages
C11408 Number of RELEASE CONFIRM messages
C11409 Number of RELEASE INDICATION messages
C11410 Number of UNIT DATA REQUEST messages
C11411 Number of UNIT DATA INDICATION messages
C11412 Number of CHANNEL ACTIVATION messages
C11413 Number of CHANNEL ACTIVATION ACK messages

Confidential and Proprietary Information of ZTE CORPORATION 247


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Counter No. Counter Definition


C11414 Number of CHANNEL ACTIVATION Negative ACK messages
C11415 Number of CONNECTION FAILURE INDICATION messages
C11416 Number of DEACTIVATE SACCH messages
C11417 Number of ENCRYPTION COMMAND messages
C11418 Number of HANDOVER DETECTION messages
C11419 Number of MEASUREMENT RESULT messages
C11420 Number of MODE MODIFY REQUEST messages
C11421 Number of MODE MODIFY ACKNOWLDGE messages
C11422 Number of MODE MODIFY NEGATIVE ACKNOWLDGE messages
C11423 Number of PHYSICAL CONTEXT REQUEST messages
C11424 Number of PHYSICAL CONTEXT CONFIRM messages
C11425 Number of RF CHANNEL RELEASE messages
C11426 Number of MS POWER CONTROL messages
C11427 Number of BS POWER CONTROL messages
C11428 Number of PREPROCESSED CONFIGURE messages
C11429 Number of PREPROCESSED MEASUREMENT RESULT messages
C11430 Number of RF CHANNEL RELEASE ACK messages
C11431 Number of SACCH INFO MODIFY messages

Abis-interface Counters Explanation


C11401
Definition

Number of DATA REQUEST messages


Description

C11401 represents number of data REQUEST message needs


acknowledgement in the messages send from BSC to LAPD.
Measurement Point

C11401 increments when BSC sends DATA REQUEST message to LAPD.

C11402
Definition

Number of DATA INDICATION messages


Description

C11402 represents number of data indication messages that BSC


receives through Abis-interface.

248 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 14 - Abis-Interface Signaling

Measurement Point

C11402 increments when BSC receives DATA INDICATION message.

C11403
Definition

Number of ERROR INDICATION messages


Description

When an error occurs in radio channel, BTS sends ERROR INDICATION


message to BSC. C11403 represents number of ERROR INDICATION
messages that BSC receives through Abis-interface.
Measurement Point

C11403 increments when BSC receives ERROR INDICATION message.

C11404
Definition

Number of ESTABLISH REQUEST messages


Description

C11404 represents number of ESTABLISH REQUEST messages that


BSC sends to LAPD. Initially BSC receives short message through A-
interface that BSC sends to MS. To originate link establishment process
for short message to MS, BSC sends ESTABLISH REQUEST message to
LAPD.
Measurement Point

C11404 increments when BSC sends ESTABLISH REQUEST message to


LAPD.

C11405
Definition

Number of ESTABLISH CONFIRM messages


Description
C11405 represents number of confirmation messages that BSC
receives through Abis-interface. Initially BSC receives ESTABLISH
CONFIRM message from LAPD. ESTABLISH CONFIRM message
indicates that the link is established successfully. At this time BSC
sends short message to MS.
Measurement Point

C11405 increments when BSC receives ESTABLISH CONFIRM message.

Confidential and Proprietary Information of ZTE CORPORATION 249


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C11406
Definition

Number of ESTABLISH INDICATION messages


Description

C11406 represents number of link ESTABLISH INDICATION messages


that BSC receives through Abis-interface. Initially MS receives
assignment command or handover command from BSC. Then MS
sends SABM frame to BTS. When BTS receives SABM frame, it sends
link ESTABLISH INDICATION message to BSC. At this time BSC sends
short message to MS.
Measurement Point

C11406 increments when BSC receives ESTABLISH INDICATION


message.

C11407
Definition

Number of RELEASE REQUEST messages


Description

C11407 represents number of RELEASE REQUEST through Abis-


interface that BSC sends to LAPD.
Measurement Point

C11407 increments when BSC sends RELEASE REQUEST message to


LAPD.

C11408
Definition

Number of RELEASE CONFIRM messages


Description

C11408 represents number of RELEASE CONFIRM messages that BSC


receives through Abis-interface.
Measurement Point

C11408 increments when BSC receives RELEASE CONFIRM message.

C11409
Definition

Number of RELEASE INDICATION messages

250 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 14 - Abis-Interface Signaling

Description

After the BSC sends RELEASE REQUEST, the MS releases the channel, and
the BTS sends the BSC the RELEASE INDICATION as a reply. This counter
provides statistics for the number of release confirm messages that BSC
receives through Abis-interface.

Measurement Point

C11409 increments when BSC receives RELEASE INDICATION message.

C11410
Definition

Number of UNIT DATA REQUEST messages


Description

C11410 represents number of unacknowledged data REQUEST


messages through Abis-interface that BSC sends to LAPD.
Measurement Point

C11410 increments when BSC sends UNIT DATA REQUEST message to


LAPD.

C11411
Definition

Number of UNIT DATA INDICATION messages


Description
C11411 represents number of unacknowledged data indication
messages that BSC receives through Abis-interface.
Measurement Point
C11410 increments when BSC sends UNIT DATA INDICATION message
to LAPD.

C11412
Definition
Number of CHANNEL ACTIVATION messages
Description

C11412 represents number of channel activation messages send from


BSC to LAPD. Initially BSC gets ready to activate a channel due to all
type of causes. Then the BSC sends CHANNEL ACTIVATION message to
BTS to start channel activation flow.

Confidential and Proprietary Information of ZTE CORPORATION 251


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Measurement Point
C11412 increments when BSC sends CHANNEL ACTIVATION message
to LAPD.

C11413
Definition

Number of CHANNEL ACTIVATION ACK messages


Description

C11413 represents number of channel activation acknowledgement


messages send from BSC to LAPD. Initially BTS activate channel due to
CHANNEL ACTIVATION message from BSC. After completing channel
activation, BTS sends CHANNEL ACTIVATION ACK message to BSC.
CHANNEL ACTIVATION ACK message is a response from BTS to
CHANNEL ACTIVATION message from BSC.
Measurement Point

C11414 increments when BSC receives CHANNEL ACTIVATION ACK


message from BTS.

C11414
Definition

Number of CHANNEL ACTIVATION Negative ACK messages


Description

When the BTS cannot complete channel activation due to a cause (like
a TRX fault), it sends CHANNEL ACTIVATION NEGATIVE ACK to the
BSC. This counter provides statistics for the number of channel
activation failure acknowledgement messages that BSC receives
through Abis-interface.
Measurement Point

C11414 increments when BSC receives CHANNEL ACTIVATION


NEGATIVE ACK message from BTS.

C11415
Definition

Number of CONNECTION FAILURE INDICATION messages


Description

C11415 represents number of channel activation failure


acknowledgement messages that BSC receives through Abis-interface.
Initially BTS can not establish connection with MS due to different
causes like TRX fault. Then the BTS sends CONNECTION FAILURE
INDICATION to BSC to inform it about connection failure.

252 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 14 - Abis-Interface Signaling

Measurement Point

C11415 increments when BSC receives CONNECTION FAILURE


INDICATION message from.

C11416
Definition

Number of DEACTIVATE SACCH messages


Description

C11416 represents number of DEACTIVATE SACCH messages send


from BSC to LAPD. Initially BSC is ready to deactivate SACCH due to
radio channel release. Then BSC SENDS DEACTIVATE SACCH message
to LAPD to start deactivation flow.
Measurement Point

C11416 increments when BSC sends DEACTIVATE SACCH message to


LAPD.

C11417
Definition

Number of ENCRYPTION COMMAND messages


Description

C11417 represents number of encryption commands messages send


from BSC to LAPD. Initially BSC sends ENCRIPTION COMMAND
message to MS to perform encryption process.
Measurement Point

C11417 increments when BSC sends ENCRYPTION COMMAND message


to LAPD.

C11418
Definition
Number of HANDOVER DETECTION messages
Description

C11418 represents number of handover detection messages that BSC


receives through Abis-interface. Initially MS receives handover
command from BTS during Intra-MSC external handover-in process.
Then MS sends SABM frame to start network access process. BTS
sends HANDOVER DETECTION message to inform BSC after receiving
SABM frame from MS.

Confidential and Proprietary Information of ZTE CORPORATION 253


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

FIGURE 18 - EXTERNAL HANDOVER IN PROCESS (PART FLOW)

BSC:Souce MSC MS BTS BSC:Dest

HANDOVER COMMAND
HANDOVER COMMAND
SABM
HANDOVER DETECT
UA
A1

Measurement Point

Refer point A1 in FIGURE 18.

C11419
Definition

Number of MEASUREMENT RESULT messages


Description

C11419 represents number of received MEASUREMENT RESULT


messages from BTS among Abis-interface messages received at BSC.
Measurement Point

C11419 increments when BSC receives MEASUREMENT RESULT


messages in Abis-interface message.

C11420
Definition

Number of MODE MODIFY REQUEST messages


Description
C11421 represents number of MODE MODIFY REQUEST messages
that BSC sends through Abis-interface during assignment or
handover process.
If assigned channel type is consistent with current channel type
and channel modes are inconsistent then BSC sends MODE MODIFY
REQUEST to BTS. At this time, C11420 increments
Measurement Point

C11420 increments when BSC sends MODE MODIFY REQUEST


message to BTS.

254 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 14 - Abis-Interface Signaling

C11421
Definition

Number of MODE MODIFY ACK messages


Description

C11422 represents number of MODE MODIFY ACK messages that BSC


receives through Abis-interface. Initially BTS receives MODE MODIFY
REQUEST message from BSC. Then the BTS sends MODE MODIFY ACK
message to BSC in reply.
Measurement Point

C11421 increments when BSC receives MODE MODIFY ACK message in


Abis-interface message.

C11422
Definition

Number of MODE MODIFY Negative ACK messages


Description

C11422 represents number of MODE MODIFY Negative ACK messages


that BSC receives through Abis-interface. Initially BTS receives MODE
MODIFY REQUEST message from BSC. If BTS can not complete channel
mode modification due to some causes, the BTS sends negative
acknowledgment to BSC in reply.
Measurement Point

C11422 increments when BSC receives MODE MODIFY NACK message


in Abis-interface message.

C11423
Definition

Number of PHYSICAL CONTEXT REQUEST messages


Description

C11423 represents number of PHYSICAL CONTEXT REQUEST messages


that BSC sends through Abis-interface.
Measurement Point

C1423 increments when BSC sends PHYSICAL CONTEXT REQUEST


message to BTS.

Confidential and Proprietary Information of ZTE CORPORATION 255


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C11424
Definition

Number of PHYSICAL CONTEXT CONFIRM messages


Description

C11425 represents number of PHYSICAL CONTEXT CONFIRM messages


that BSC receives through Abis-interface.
Measurement Point

C11424 increments when BSC receives PHYSICAL CONTEXT CONFIRM


through Abis-interface message.

C11425
Definition

Number of RF CHANNEL RELEASE messages


Description

C11425 represents number of RF CHANNEL RELEASE messages send


from BSC to LAPD. BSC sends RF CHANNEL RELEASE message to BTS
to indicate channel release.
Measurement Point

C11426 increments when BSC sends RF CHANNEL RELEASE message.

C11426
Definition

Number of MS POWER CONTROL messages


Description

BSC sends the MS POWER CONTROL message to the MS for power


control. This counter provides statistics of the quantity of MS POWER
CONTROL messages send from BSC to LAPD.
Measurement Point

C11426 increments when BSC sends MS POWER CONTROL message.

C11427
Definition

Number of BS POWER CONTROL messages

256 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 14 - Abis-Interface Signaling

Description

BSC sends the BS POWER CONTROL message to the BS for power


control. This counter provides statistics for the number of BS POWER
CONTROL messages send from the BSC to LAPD.
Measurement Point

C11427 increments when BSC sends BS POWER CONTROL message to


BTS.

C11428
Definition

Number of PREPROCESSED CONFIGURE messages


Description

C11428 represents number of PREPROC CONFIG messages send from


BSC to LAPD.
Measurement Point

C11429 increments when BSC sends PREPROC CONFIG message.

C11429
Definition

Number of PREPROCESSED MEASUREMENT RESULT messages


Description

C11429 represents number of PREPROCESSED MEASUREMENT RESULT


messages that BSC receives through Abis-interface from BTS.
Measurement Point

C11429 increments when BSC receives PREPROCESSED


MEASUREMENT RESULT message in Abis-interface message.

C11430
Definition

Number of RF CHANNEL RELEASE ACK messages


Description

C11430 represents RF CHANNEL RELEASE ACK messages that BSC


receives through Abis-interface. Initially BSC sends RF CHANNEL
RELEASE message to BTS and MS to start channel release flow. Then
BTS and MS complete channel release process and send RF CHANNEL
RELEASE ACK message as reply to BSC.

Confidential and Proprietary Information of ZTE CORPORATION 257


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Measurement Point

C11230 increments when BSC receives RF CHANNEL RELEASE ACK in


Abis-interface message.

C11431
Definition

Number of SACCH INFO MODIFY messages


Description

C11431 numbers of SACCH INFO MODIFY messages send from BSC to


LAPD. BSC sends SACCH INFO MODIFY message to intra-cell MS to
inform it about system information modification.
Measurement Point

C11431 increments when BSC sends SACCH INFO MODIFY message.

258 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 15

Resource Availability
Measurement

This chapter covers the following topics:

Resource Availability Counters

Resource Availability Counters


Resource Availability Measurement involves counters that provide statistics
of channels utilization in a cell. These counters keep the record of the
following statistics.

Number of available SDCCH


TCH/H and TCH/F
Average and maximum busy quantities
Total busy time
Total congestion time in cell.
Statistical unit is cell.
Table 23 lists all the Resource Availability Counters.

TABLE 23 RESOURSE AVAILABILITY COUNTERS

Counter No. Counter Definition


C11501 Mean number of available SDCCHs
C11502 Mean number of unavailable SDCCHs

Confidential and Proprietary Information of ZTE CORPORATION 259


C11503 Maximum number of busy SDCCHs
C11504 Mean number of busy SDCCHs
C11505 Total SDCCH busy time
C11506 Total SDCCH congestion time
C11507 Mean number of available TCH/Hs
C11508 Mean number of unavailable TCH/Hs
C11509 Maximum number of busy TCH/Hs
C11510 Mean number of busy TCH/Hs
C11511 Total TCH/H busy time
C11512 Total TCH/H congestion time
C11513 Mean number of available TCH/Fs
C11514 Mean number of unavailable TCH/Fs
C11515 Maximum number of busy TCH/Fs
C11516 Mean number of busy TCH/Fs
C11517 Total TCH/F busy time
C11518 Total TCH/F congestion time
C11519 Total number of TRXs
C11520 Total number of healthy TRXs
C11521 Seizure duration of reserved full rate channel

Resource Availability Counters


Explanation
C11501
Definition

Mean number of available SDCCHs


Description

C11501 represents mean number of SDCCHs available for use in the


observed cell.
Measurement Point

C11501 records the result at periodic querying of data base.

C11502
Definition

Mean number of unavailable SDCCHs

260 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 15 - Resource Availability Measurement

Description

C11502 represents mean number of SDCCHs unavailable for use in the


observed cell including both, idle and busy SDCCHs.
Measurement Point

C11502 records the result at periodic querying of data base.

C11503
Definition

Maximum number of busy SDCCHs


Description

C11503 represents maximum number of SDCCHs that are busy during


the observation period.
C11503 increments, if MS occupies SDCCH successfully. C11503
decrements, if MS fails to occupy SDCCH. BSC updates C11503
according to number of seize SDCCHs in a cell, during measurement
query. Before MS releases SDCCH in a cell, C11503 also updates
number of seize SSDCH channels. C11503 updates number of seize
SDCCHs because seizure of SDCCHs in a cell of previous measurement
cycle is taken into account.
Measurement Point

C11503 increments at three measurement points:


If maximum busy quantity exceeds the represented value after
SDCCH in cell is seize successfully.
If maximum busy quantity exceeds the represented value before
SDCCH in cell is released.
If maximum busy quantity exceeds the represented value at time
of measurement query.

C11504
Definition

Mean number of busy SDCCH


Description

C11504 represents mean number of SDCCHs that are busy during the
observation period.
Measurement Point

During the time measurement cycle, system updates the status of


SDCCH (busy or idle) in C11504.

Confidential and Proprietary Information of ZTE CORPORATION 261


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C11505
Definition

Total SDCCHs busy time


Description

C11505 represents total time of SDCCH seizures in a cell. C11505


shows traffic of SDCCHs in a cell.
Measurement Point

C11505 increments when:


MS seizes SDCCH successfully.
MS releases SDCCH.
During timely measurement.
Reported measurement value is accumulation of each measurement
value. After each measurement, current time is set as last time for the
next measurement. When MS seizes SDCCH successfully, number of
seized SDCCH increments by one. When MS releases SDCCH, number
of seized SDCCH decrements by one.
Measurement formula:

(Current time – time of last measurement) X (Number of seized


SDCCHs)
FIGURE 19 shows measurement calculation procedure.

FIGURE 19 - CALCULATING SDCCH BUSY TIME

Time Time

Occupation time + = (current time - previous


SDCCH occupy or release record time) × occupied quantity
Previous record time = current time
1 added to or reduced from the occupied quantity
Measurement
circle SDCCH occupy or release
Same as the above calculation

Measurement value Same as the above calculation

C11506
Definition

Total SDCCH congestion time

262 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 15 - Resource Availability Measurement

Description

C11506 represents total SDCCH congestion time. At this time cell can
not apply for SDCCH. C11506 marks congestion when MS fails to
occupy SDCCH. Similarly counter C11506 clears congestion mark when
MS successes to occupy SDCCH. Initially counter C11506 sets
congestion mark during SDCCH application. C11506 obtains congestion
time at this period by reducing the previous record congestion time
from current time. Sum of congestion time of each calculation is the
total SDCH channel congestion time.
Measurement Point

C11506 increments at three points:


If congestion mark is set before MS attempts to occupy SDCCH
If congestion mark is set before MS release SDCCH
If congestion mark is set at time of measurement query

C11507
Definition

Mean number of available TCH/Hs


Description

C11507 represents mean number of TCH/Hs available for use in the


observed cell.
Measurement Point

Counter increments when database is queried periodically.

C11508
Description

Average number of unavailable TCH/Hs


Definition
C11507 represents mean number of TCH/Hs unavailable for use in the
observed cell.
Measurement Point

Counter increments when database is queried periodically.

C11509
Definition

Maximum number of busy TCH/Hs


Description

C11509 represents maximum number of seize TCH/Hs in a cell.

Confidential and Proprietary Information of ZTE CORPORATION 263


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C11509 increments if MS occupies TCH/H successfully. Similarly if MS


does not occupy TCH/H successfully, counter C11509 decrements by 1.
C11509 updates according to number of seize TCH/Hs in cell at the
time of measurement query. Before MS releases TCH/H in a cell,
C11509 updates number of seize TCH/Hs in a cell. This is done
because seizure of TCH/Hs in a cell of previous measurement cycle is
taken into account.
Measurement Point

C11509 increments at three measurement points:


If maximum busy TCH/Hs exceeds the record after successful
TCH/H seizure.
If maximum busy TCH/Hs exceeds the record after successful
TCH/H release.
If maximum busy TCH/Hs exceeds during measurement cycle.

C11510
Definition

Mean number of busy TCH/Hs


Description

C11510 represents mean number of seize TCH/Hs channels in a cell,


during measurement cycle.
In BSC, the seize number of TCH/Hs at cyclic measurement report
shows number of busy TCH/Hs.
Measurement Point

C11510 updates seize number of TCH/H after successful TCH/H seizure


and release. C11510 increments and measurement report is send to
OMC-R.

C11511
Definition

Total TCH/H busy time


Description

C11511 represents total seizure time of each TCH/H in a cell. Total


number of seize TCH/H in a cell shows TCH/H traffic in that cell.
There are three measurement points:

C11511 increments when MS obtains TCH/H successfully.


C11511 increments when MS releases TCH/H.
C11511 increments at time of measurement of TCH/H

264 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 15 - Resource Availability Measurement

Calculation formula

(Current time – Time of previous measurement) × (Number of MS


which are occupying channels)

C11512
Definition

Total TCH/H congestion time


Description

C11512 represents total TCH/H congestion time. At this time cell can
not apply for TCH/H. C11512 marks congestion when MS fails to
occupy TCH/Hs. Similarly C11512 clears congestion mark when MS
successes to occupy TCH/Hs. Initially C11512 sets congestion mark
during TCH/H application. C11512 obtains congestion time at this
period by subtracting the previous record congestion time from current
time. Sum of congestion time of each calculation is the total TCH/H
congestion time.
Measurement Point

There are three measurement points:


Counter C11512 increments if counter C11512 sets congestion
mark before MS attempts to occupy TCH/H.
Counter C11512 increments if counter C11512 sets congestion
mark before MS release TCH/H.
Counter C11512 increments if counter C11512 sets congestion
mark at the time of measurement query.

C11513
Definition

Mean number of available TCH/Fs


Description

C11513 represents mean number of TCH/Hs available for use in the


observed cell.
Measurement Point

Counter increments when database is queried periodically.

C11514
Definition

Average number of unavailable TCH/Fs

Confidential and Proprietary Information of ZTE CORPORATION 265


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Description

C11514 represents mean number of TCH/Hs unavailable for use in the


observed cell.
Measurement Point

Counter increments when database is queried periodically.

C11515
Definition

Maximum number of busy TCH/Fs


Description

C11515 represents maximum number of seize TCH/Fs in a cell.


C11515 increments if MS occupies TCH/F successfully. Similarly if MS
does not occupy TCH/F successfully, counter C11515 decrements by 1.
C11509 updates according to number of seize TCH/Hs in cell at the
time of measurement query. Before MS releases TCH/F in a cell,
C11509 updates number of seize TCH/Fs in a cell. This is done because
seizure of TCH/Fs in a cell of previous measurement cycle is taken into
account.
Measurement Point

C11515 increments at three measurement points:


If maximum busy TCH/Fs exceeds the record after successful
TCH/F seizure.
If maximum busy TCH/Fs exceeds the record after successful
TCH/F release.
If maximum busy TCH/Fs exceeds during measurement cycle.

C11516
Definition

Mean number of busy TCH/Fs


Description

C11516 represents mean number of seize TCH/F channels in a cell


during measurement cycle. In BSC, seize number of TCH/Fs at cyclic
measurement report indicates the average busy quantity.
Measurement Point

C11516 updates seize quantity after successful TCH/F seizure and


release. C11516 increments and sends it to cyclic measurement report
in OMC-R database.

266 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 15 - Resource Availability Measurement

C11517
Definition

Total TCH/F busy time


Description

C11517 represents total seize time of TCH/F in a cell. C11517 shows


TCH/F traffic in a cell
Measurement Point

C11517 increments when:


MS obtains TCH/F channels successfully
MS releases TCH/F channel
Database query
Calculation Formula

(Current time – time point of previous measurement) × (Number of


MS which are occupying TCH/F channels)
C11517 obtains measurement value by accumulating each
measurement value.
After each time of accumulation, current time replaces time of
previous measurement.
C11517 increments by 1 at TCH/F seizure
C11517 decrements by 1 at TCH/F release
FIGURE 13 shows calculation procedure of measurement of total
busy time of TCH/F channel.

C11518
Definition

Total TCH/F congestion time


Description

C11518 records the congestion time of TCH/F.


Calculation Formula

Congestion time = Current Time – Previous Congestion Time


Measurement Point

C11518 increments when:


If congestion mark is set before MS attempts to seize TCH/F
If congestion mark is set before MS release TCH/F
If it sets congestion mark is set at the time of measurement query

Confidential and Proprietary Information of ZTE CORPORATION 267


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C11519
Definition

Total number of TRXs


Description

C11519 represents total number of TRXs configured in a cell.


Measurement Point

Querying OMC-R database during periodical measurement report

C11520
Definition

Total number of healthy TRXs


Description

C11520 represents total TRXs which are working properly in a cell.


Measurement Point

Querying OMC-R database during periodical measurement report

C11521
Definition

Seizure duration of reserved full rate channel


Description

Total time of using reserved channel in cell, which reflects traffic of


reserved channels.
There are three measurement points:

C11521 increments after obtaining the reserve channel resources.


C11521increments after releasing reserve channel resources.
C11521 increments during regular measurement.
Calculation Formula

(Current time – time point of last measurement) X number of MSs


occupying reserved channels.

268 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 16

Sub Cell Measurement

This chapter covers the following topics:

Sub Cell Counters

Sub Cell Counters


It is important to note here that all the sub cells are part of the dual
frequency cell. These counters are for the sub cells of dual frequency cells.

Sub Cell Measurement involves counters that provide statistics such as:

Radio Resources of second sub cell


Handover between first sub cell and second sub cell
Resource Utilization of second sub cell

TABLE 24 - SUB CELL COUNTERS

Counter No. Definition


C12001 Total number of available TCH/Fs in the second sub cell
C12002 Total number of unavailable TCH/Fs in the second sub cell
C12003 Total number of available TCH/Hs in the second sub cell
C12004 Total number of unavailable TCH/Hs in the second sub cell
Number of handover attempts from the first sub cell to the second sub
C12005
cell
Number of handover execution from the first sub cell to the second
C12006
sub cell
Number of successful handover from the first sub cell to the second
C12007
sub cell
Number of handover attempts from the second sub cell to the first sub
C12008
cell
Number of handover execution from the second sub cell to the first
C12009
sub cell

Confidential and Proprietary Information of ZTE CORPORATION 269


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Counter No. Definition


Number of successful handover from the second sub cell to the first
C12010
sub cell
C12011 Number of handover attempts in the second sub cell
C12012 Number of handover execution in the second sub cell
C12013 Number of successful handover in the second sub cell
Number of outgoing inter-cell handover attempts of the second sub
C12014
cell
Number of outgoing inter-cell handover execution of the second sub
C12015
cell
Number of successful outgoing inter-cell handover of the second sub
C12016
cell
Handover attempts due to uplink receiving strength of the full rate
C12017
second sub cell
Handover attempts due to downlink receiving strength of the full rate
C12018
second sub cell
Handover attempts due to uplink quality of the full rate second sub
C12019
cell
Handover attempts due to downlink quality of the full rate second sub
C12020
cell
C12021 Handover attempts due to PBGT of the full rate second sub cell
C12022 Handover attempts due to traffic of the full rate second sub cell
C12023 Handover attempts due to other causes of the full rate second sub cell
Handover attempts due to uplink receiving strength of the half rate
C12024
second sub cell
Handover attempts due to downlink receiving strength of the half rate
C12025
second sub cell
Handover attempts due to uplink quality of the half rate second sub
C12026
cell
Handover attempts due to downlink quality of the half rate second sub
C12027
cell
C12028 Handover attempts due to PBGT of the half rate second sub cell
C12029 Handover attempts due to traffic of the half rate second sub cell
C12030 Handover attempts due to other causes of the half rate second sub cell
Number of attempts of TCH/F seizure of the second sub cell (used for
C12031
assignment)
Number of successful TCH/F seizure of the second sub cell (used for
C12032
assignment)
Number of failed TCH/F seizure of the second sub cell (used for
C12033
assignment)
Number of attempts of TCH/F seizure of the second sub cell (used for
C12034
handover)
Number of successful TCH/F seizure of the second sub cell (used for
C12035
handover)

270 Confidential and Proprietary Information of ZTE CORPORATION


Chapter16 - Sub Cell Measurement

Counter No. Definition


Number of failed TCH/F seizure of the second sub cell (used for
C12036
handover)
Number of attempts of TCH/H seizure of the second sub cell (used for
C12037
assignment)
Number of successful TCH/H seizure of the second sub cell (used for
C12038
assignment)
Number of failed TCH/H seizure of the second sub cell (used for
C12039
assignment)
Number of attempts of TCH/H seizure of the second sub cell (used for
C12040
handover)
Number of successful TCH/H seizure of the second sub cell (used for
C12041
handover)
Number of failed TCH/H seizure of the second sub cell (used for
C12042
handover)
C12043 Total number of TCH/F call drops in the second sub cell
C12044 Total number of TCH/H call drops in the second sub cell
C12045 Total TCH/F busy time in the second sub cell
C12046 Total TCH/H busy time in the second sub cell

Sub Cell Counters Explanation


C12001
Definition

Total number of available TCH/Fs in the second sub cell


Description

Total number of TCH/Fs those are available for use in the second sub
cell.
Measurement Point

Querying the database in periodic measurement reporting

C12002
Definition

Total number of unavailable TCH/Fs in the second sub cell


Description

Total number of TCH/Fs those are unavailable for use in the second
sub cell.
Measurement Point

Querying the database in periodic measurement reporting

Confidential and Proprietary Information of ZTE CORPORATION 271


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C12003
Definition

Total number of available TCH/Hs in the second sub cell


Description

Total number of TCH/Hs those are available for use in the second sub
cell.
Measurement Point

Querying the database in periodic measurement reporting

C12004
Definition

Total number of unavailable TCH/Hs in the second sub cell


Description

Total number of TCH/Hs those are available for use in the second sub
cell.
Measurement Point

Querying the database in periodic measurement reporting

C12005
Definition

Number of handover attempts from the first sub cell to the second sub
cell
Description

Number of handover attempts from the first sub cell to the second sub
cell in the dual-frequency cell
Measurement Point

Counting upon successful request for the channel of the second sub
cell due to the handover attempt from the first sub cell to the second
sub cell in the dual-frequency cell

C12006
Definition

Number of handover execution from the first sub cell to the second sub
cell

272 Confidential and Proprietary Information of ZTE CORPORATION


Chapter16 - Sub Cell Measurement

Description

During handover from first sub cell to second sub cell, successful
activation of the destination channel in the second sub cell indicates
normal handover execution.
Measurement Point

Counting upon receiving channel activation response from second sub


cell, during handover from the first sub cell to the second sub cell.

C12007
Definition

Number of successful handover from the first sub cell to the second
sub cell
Description

During handover from the first sub cell to the second sub cell,
reception of Assignment Complete message on destination channel
indicates successful handover.
Measurement Point

C12007 increments at reception of assignment complete message from


second sub cell, during handover from the first sub cell to the second
sub cell.

C12008
Definition

Number of handover attempts from the second sub cell to the first sub
cell
Description

Number of handover attempts from the second sub cell to the first sub
cell in the dual-frequency cell
Measurement Point

C12008 increments at successful channel request due to the handover


attempt from the second sub cell to the first sub cell.

C12009
Definition

Number of handover execution from the second sub cell to the first sub
cell

Confidential and Proprietary Information of ZTE CORPORATION 273


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Description

During handover from the first sub cell to the second sub, successful
channel activation in the second sub cell indicates normal handover
execution.
Measurement Point

C12009 increments at reception of channel activation message from


second sub cell.

C12010
Definition

Number of successful handover from the second sub cell to the first
sub cell
Description

During handover from second sub cell to the first sub cell in, reception
of Assignment Complete message on the destination channel indicates
successful handover.
Measurement Point

C12010 increments at reception of Assignment Complete message on


the destination channel of the first sub cell.

C12011
Definition

Number of handover attempts in the second sub cell


Description

Number of internal handover attempts in the second sub cell in the


dual-frequency cell
Measurement Point

Counting upon successful channel application for internal handover


attempt in the second sub cell in the dual-frequency cell

C12012
Definition

Number of handover execution in the second sub cell


Description

During internal handover in the second sub cell, successful activation


of the destination channel indicates normal handover execution.

274 Confidential and Proprietary Information of ZTE CORPORATION


Chapter16 - Sub Cell Measurement

Measurement Point

C12012 increments at activation response of destination channel


during internal handover in the second sub cell.

C12013
Definition

Number of successful handover in the second sub cell


Description

During internal handover in the second sub cell, reception of


Assignment Complete message from the MS on the destination channel
indicates successful handover.
Measurement Point

C12013 increments at reception of Assignment Complete message on


destination channel during internal handover in the second sub cell.

C12014
Definition

Number of outgoing inter-cell handover attempts of the second sub cell


Description

Number of handover attempts from the second sub cell to the BSC cell.
Measurement Point

C12014 increments upon handover attempt to the destination cell in


the BSC from the second sub cell.

C12015
Definition

Number of outgoing inter-cell handover execution of the second sub


cell
Description

Number of handover execution from the second sub cell in the dual-
frequency cell to the BSC cell.
Measurement Point

Counting upon sending of resource availability message to the former


channel instance after the destination channel is activated.

Confidential and Proprietary Information of ZTE CORPORATION 275


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C12016
Definition

Number of successful outgoing inter-cell handover of the second sub


cell
Description

Number of successful handover outs from second sub to the BSC cell.
Reception of Handover Complete message on the destination channel
indicates successful handover. After that, the destination channel
instance notifies the source instance for successful handover out
through the SPS_PNPN_HO_COM message.
Measurement Point

Counting when the source channel instance receives the


SPS_PNPN_HO_COM message, in handover from the second sub cell in
the dual-frequency cell to the BSC cell

C12017
Definition

Handover attempts due to uplink receiving strength of the full rate


second sub cell
Description

This counter represents the number of handover attempts on the


TCH/F channel of the second sub cell due to uplink receiving strength.
Handover cases such as intra-BSC inter-cell handover and external
handover. It provides frequency information about handover from
serving cell’s second sub cell due to uplink receiving strength.
Measurement Point

C12017 increments at reception of Radio Apply (intra-BSC inter-cell


handover) or HANDOVER REQUIRED (external handover) due to uplink
receiving strength.

C12018
Definition

Handover attempts due to downlink receiving strength of the full rate


second sub cell
Description

This counter represents the number of handovers on the TCH/F


channel of the second sub cell due to downlink receiving strength.
Handover includes intra-BSC inter-cell handover and external handover.
It provides frequency information about handover from serving cell’s
second sub cell due to downlink receiving strength.

276 Confidential and Proprietary Information of ZTE CORPORATION


Chapter16 - Sub Cell Measurement

Measurement Point

C12018 increments at reception of Radio Apply (intra-BSC inter-cell


handover) or HANDOVER REQUIRED (external handover) due to uplink
receiving strength.

C12019
Definition

Handover attempts due to uplink quality of the full rate second sub cell
Description

This counter represents the number of handovers due to uplink quality


on the TCH/F channel of the second sub cell. Handover includes intra-
BSC inter-cell handover and external handover. It helps to provide
frequency information of handover of the serving cell’s second sub cell
due to uplink receiving strength.
Measurement Point

C12019 increments at reception of Radio Apply (intra-BSC inter-cell


handover) or HANDOVER REQUIRED (external handover) due to uplink
receiving strength.

C12020
Definition

Handover attempts due to downlink quality of the full rate second sub
cell
Description

This counter represents the number of handovers due to downlink


quality on the TCH/F channel of the second sub cell. Handover includes
intra-BSC inter-cell handover and external handover. It helps to
provide frequency information of handover of the serving cell’s second
sub cell due to uplink receiving strength.
Measurement Point

C12020 increments at reception of Radio Apply (intra-BSC inter-cell


handover) or HANDOVER REQUIRED (external handover) due to uplink
receiving strength.

C12021
Definition

Handover attempts due to PBGT of the full rate second sub cell
Description

This counter represents the number of handovers due to PBGT on the


TCH/F channel of the second sub cell. Handover includes intra-BSC

Confidential and Proprietary Information of ZTE CORPORATION 277


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

inter-cell handover and external handover. It helps to provide


frequency information of handover of the serving cell’s second sub cell
due to uplink receiving strength.
Measurement Point

C12021 increments at reception of Radio Apply (intra-BSC inter-cell


handover) or HANDOVER REQUIRED (external handover) due to uplink
receiving strength.

C12022
Definition

Handover attempts due to traffic of the full rate second sub cell
Description

This counter represents the number of handovers due to traffic on the


TCH/F channel of the second sub cell. Handover includes intra-BSC
inter-cell handover and external handover. It helps to provide
frequency information of handover of the serving cell’s second sub cell
due to uplink receiving strength.
Measurement Point

C12022 increments at reception of Radio Apply (intra-BSC inter-cell


handover) or HANDOVER REQUIRED (external handover) due to uplink
receiving strength.

C12023
Handover attempts due to other causes of the full rate second sub cell
Description

This counter represents the number of handovers due to other causes


on the TCH/F channel of the second sub cell. Handover includes intra-
BSC inter-cell handover and external handover. It helps to provide
frequency information of handover of the serving cell’s second sub cell
due to uplink receiving strength.
Measurement Point

C12023 increments at reception of Radio Apply (intra-BSC inter-cell


handover) or HANDOVER REQUIRED (external handover) due to uplink
receiving strength.

C12024
Definition

Handover attempts due to uplink receiving strength of the half rate


second sub cell

278 Confidential and Proprietary Information of ZTE CORPORATION


Chapter16 - Sub Cell Measurement

Description

This counter represents the number of handovers (including intra-BSC


inter-cell handover and external handover), which is due to uplink
receiving strength, on the TCH/F channel of the second sub cell. It
helps to provide frequency information of handover of the serving cell’s
second sub cell due to uplink receiving strength.
Measurement Point

In the second sub cell, if the current channel is TCH/F and after being
judged by handover algorithm, Radio Apply (intra-BSC inter-cell
handover) or HANDOVER REQUIRED (external handover) are
transmitted due to uplink receiving strength, then measurement
increments.

C12025
Definition

Handover attempts due to downlink receiving strength of the half rate


second sub cell
Description

This index represents the number of handover (including intra-BSC


inter-cell handover and external handover), which is due to uplink
receiving strength, on the TCH/F channel of the second sub cell. It
helps to provide frequency information of handover of the serving cell’s
second sub cell due to uplink receiving strength.
Measurement Point

In the second sub cell, if the current channel is TCH/F and after being
judged by handover algorithm, Radio Apply (intra-BSC inter-cell
handover) or HANDOVER REQUIRED (external handover) are
transmitted due to uplink receiving strength, then measurement
increments.

C12026
Definition

Handover attempts due to uplink quality of the half rate second sub
cell
Description

This index represents the number of handover (including intra-BSC


inter-cell handover and external handover), which is due to uplink
receiving strength, on the TCH/F channel of the second sub cell. It
helps to provide frequency information of handover of the serving cell’s
second sub cell due to uplink receiving strength.

Confidential and Proprietary Information of ZTE CORPORATION 279


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Measurement Point

In the second sub cell, if the current channel is TCH/F and after being
judged by handover algorithm, Radio Apply (intra-BSC inter-cell
handover) or HANDOVER REQUIRED (external handover) are
transmitted due to uplink receiving strength, then measurement
increments.

C12027
Definition

Handover attempts due to downlink quality of the half rate second sub
cell
Description

This index represents the number of handover (including intra-BSC


inter-cell handover and external handover), which is due to uplink
receiving strength, on the TCH/F channel of the second sub cell. It
helps to provide frequency information of handover of the serving cell’s
second sub cell due to uplink receiving strength.
Measurement Point

In the second sub cell, if the current channel is TCH/F and after being
judged by handover algorithm, Radio Apply (intra-BSC inter-cell
handover) or HANDOVER REQUIRED (external handover) are
transmitted due to uplink receiving strength, then measurement
increments.

C12028
Definition

Handover attempts due to PBGT of the half rate second sub cell
Description

This index represents the number of handover (including intra-BSC


inter-cell handover and external handover), which is due to uplink
receiving strength, on the TCH/F channel of the second sub cell. It
helps to provide frequency information of handover of the serving cell’s
second sub cell due to uplink receiving strength.
Measurement Point

In the second sub cell, if the current channel is TCH/F and after being
judged by handover algorithm, Radio Apply (intra-BSC inter-cell
handover) or HANDOVER REQUIRED (external handover) are
transmitted due to uplink receiving strength, then measurement
increments.

280 Confidential and Proprietary Information of ZTE CORPORATION


Chapter16 - Sub Cell Measurement

C12029
Definition

Handover attempts due to traffic of the half rate second sub cell
Description

This index represents the number of handover (including intra-BSC


inter-cell handover and external handover), which is due to uplink
receiving strength, on the TCH/F channel of the second sub cell. It
helps to provide frequency information of handover of the serving cell’s
second sub cell due to uplink receiving strength.
Measurement Point

In the second sub cell, if the current channel is TCH/F and after being
judged by handover algorithm, Radio Apply (intra-BSC inter-cell
handover) or HANDOVER REQUIRED (external handover) are
transmitted due to uplink receiving strength, then measurement
increments.

C12030
Definition

Handover attempts due to other causes of the half rate second sub cell
Description

This index represents the number of handover (including intra-BSC


inter-cell handover and external handover), which is due to causes
except for those of 12024~12029, on the TCH/F channel of the second
sub cell. It helps to provide frequency information of handover of the
serving cell’s second sub cell due to uplink receiving strength.
Measurement Point

In the second sub cell, if the current channel is TCH/F channel, and
after being judged by handover algorithm, Radio Apply (intra-BSC
inter-cell handover) or HANDOVER REQUIRED (external handover) are
transmitted due to causes except for those of 12024~12029, then
measurement increments.

C12031
Definition

Number of attempts of TCH/F seizure of the second sub cell (used for
assignment)
Description

Number of attempts of TCH/F seizure of the second sub cell (used for
assignment), including cases of successful and failed seizure

Confidential and Proprietary Information of ZTE CORPORATION 281


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Measurement Point

C12031 increments, when TCH/F activates successfully in the second


sub cell or fails.

C12032
Definition

Number of successful TCH/F seizure of the second sub cell (used for
assignment)
Description

Number of successful TCH/F seizure of the second sub cell (used for
assignment)
Measurement Point

C12032 increments when applying for the TCH/F channel succeeds.

C12033
Definition

Number of failed TCH/F seizure of the second sub cell (used for
assignment)
Description

Number of failed TCH/F seizure of the second sub cell (used for
assignment)
Measurement Point

C12033 increments when applying for the TCH/F channel fails.

C12034
Definition

Number of attempts of TCH/F seizure of the second sub cell (used for
handover)
Description

Number of attempts of TCH/F seizure of the second sub cell (used for
handover), including cases of successful and failed seizure
Measurement Point

C12034 increments at TCH/F activation in the second sub cell becomes


successful or fails.

282 Confidential and Proprietary Information of ZTE CORPORATION


Chapter16 - Sub Cell Measurement

C12035
Definition

Number of successful TCH/F seizure of the second sub-cell (used for


handover)
Description

Number of successful TCH/F seizure of the second sub-cell (used for


handover)
Measurement Point

Counter increments when applying for TCH/F channel of the second


sub cell succeeds.

C12036
Definition

Number of failed TCH/F seizure of the second sub cell (used for
handover)
Description

Number of failed TCH/F seizure of the second sub cell (used for
handover)
Measurement Point

Counter increments when applying for TCH/F channel of the second


sub cell fails.

C12037
Definition

Number of attempts of TCH/H seizure of the second sub cell (used for
assignment)
Description

Number of attempts of TCH/H seizure of the second sub cell (used for
assignment), including cases of successful and failed seizure
Measurement Point

C12037 increments if TCH/H activation successes or fails.

C12038
Definition

Number of successful TCH/H seizure of the second sub cell (used for
assignment)

Confidential and Proprietary Information of ZTE CORPORATION 283


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Description

Number of successful TCH/H seizure of the second sub cell (used for
assignment)
Measurement Point

C12038 increments when applying for TCH/H of the second sub cell
succeeds.

C12039
Definition

Number of failed TCH/H seizure of the second sub cell (used for
assignment)
Description

Number of failed TCH/H seizure of the second sub cell (used for
assignment)
Measurement Point

C12039 increments when applying for TCH/H of the second sub cell
fails.

C12040
Definition

Number of attempts of TCH/H seizure of the second sub cell (used for
handover)
Description

Number of attempts of TCH/H seizure of the second sub cell (used for
handover), including cases of successful and failed seizure
Measurement Point

C12040 increments if TCH/H activation successes or fails in the second


sub cell.

C12041
Definition

Number of successful TCH/H seizure of the second sub cell (used for
handover)
Description

Number of successful TCH/H seizure of the second sub cell (used for
handover)

284 Confidential and Proprietary Information of ZTE CORPORATION


Chapter16 - Sub Cell Measurement

Measurement Point

C12041 increments when applying for TCH/H of the second sub cell
succeeds.

C12042
Definition

Number of failed TCH/H seizure of the second sub cell (used for
handover)
Description

Number of failed TCH/H seizure of the second sub cell (used for
handover)
Measurement Point

C12042 increments when applying for TCH/H of the second sub cell
fails.

C12043
Definition

Total number of TCH/F call drop in the second sub cell


Description

Number of voice call drop on the TCH/F of the second sub cell,
involving call drop due to intra-cell handover failure (T3107 timer
overflow), inter-cell handover failure (T3103 timer overflow), handover
out failure (T8 timer overflow), wireless link failure or LAPD interrupt.
Refer to the description of Counters C00037 ~ C00039 and Counter
C00050 in Section TRX Service Counters Measurement.
Measurement Point

Counting upon receivingT3107 timer overflow, T3103 timer overflow,


T8 timer overflow, wireless link failure or LAPD interrupt message on
the TCH/F voice channel of the second sub cell

C12044
Definition

Total number of TCH/H call drops in the second sub cell


Description

Number of voice call drop on the TCH/H of the second sub cell,
involving call drop due to intra-cell handover failure (T3107 timer
overflow), inter-cell handover failure (T3103 timer overflow), handover
out failure (T8 timer overflow), wireless link failure or LAPD interrupt.
Refer to the description of Counters C00037 ~ C00039 and Counter
C00050 in TRX Service Counters Measurement.

Confidential and Proprietary Information of ZTE CORPORATION 285


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Measurement Point

Counting upon receivingT3107 timer overflow, T3103 timer overflow,


T8 timer overflow, wireless link failure or LAPD interrupt message on
the TCH/F voice channel of the second sub cell

C12045
Definition

Total TCH/F busy time in the second sub cell


Description

Total time in which TCH/Fs in the second sub cell are utilized
Measurement Point

There are three measurement points:


Accumulation upon success obtainment of TCH/F resource of the
second sub cell
Accumulation upon release of TCH/F resource of the second sub cell
Accumulation of timed measurement obtainment calculation
Measurement formula:

(Current time – Time point of the last measurement) × Number of the


MSs which are occupying channels.

C12046
Definition

Total TCH/H busy time in the second sub cell


Measurement Point

There are three measurement points:


Accumulation upon success obtainment of TCH/H resource of the
second sub cell
Accumulation upon release of TCH/H resource of the second sub
cell
Accumulation of time measurement obtainment calculation
Measurement formula

(Current time – Time point of the last measurement) × Number of the


MSs which are occupying channels.

286 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 17

A-interface Signal
Measurement

This chapter includes counters that provide signaling statistics over the A-
interface. This Chapter covers following topics:

BSSAP Message Counters


BSSMAP Message Counters

BSSAP Message Counters


Signaling over A-interface is in the form of Base Station Subsystem
Application Part (BSSAP) messages. BSSAP itself can be separated into the
base station subsystem management application part (BSSMAP) and the
direct transfer application part (DTAP).

BSSMAP include all messages exchanges between BSC and MSC that are
actually processed by the BSC. Examples are Paging, Handover and Reset
messages.

DTAP messages comprise all messages exchanged between subsystem of


the NSS and MS. DTAP messages are transparent for the BSS. DTAP
messages carry Call Control (CC) and Mobility Management (MM)
information.

Table 25 represents BSSAP message counters over A-interface.

TABLE 25 BSSAP MESSAGE COUNTERS

Counter No. Definition


C20101 Number of uplink DTAP messages
C20102 Number of downlink DTAP messages
C20103 Number of uplink BSSMAP messages
C20104 Number of downlink BSSMAP messages

Confidential and Proprietary Information of ZTE CORPORATION 287


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C20105 Number of downlink BSSMAP messages received with error.

BSSAP Message Counters Explanation


C20101
Definition

Number of uplink DTAP messages


Description

Counter ‘C20101’ represents the number of DTAP messages that MS


sends to MSC.
Measurement Point

Counter ‘C20101’ increments when first DTAP message reaches to the


BSC. BSC then passes it to the MSC.

C20102
Definition

Number of downlink DTAP messages


Description

Counter ‘C20102’ represents the number of DTAP messages that MSC


sends to the MS.
Measurement Point

Counter ‘C20102’ increments when first DTAP message reaches to the


BSC. BSC then passes it to the MS.

C20103
Definition

Number of uplink BSSMAP messages


Description

Counter ‘C20103’ represents the number of BSSMAP messages that


BSC sends to the MSC. BSC sends BSSMAP messages along with the
following messages:
Connection Request Message
Data Request Message
Unit Data Request Message
Measurement Point

Counter ‘C20103’ increments when BSC sends first BSSMAP message


to the MSC.

288 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 17 - A-interface Signal Measurement

C20104
Definition

Number of downlink BSSMAP messages


Description

Counter ‘C20104’ represents the number of BSSMAP messages that


MSC sends to the BSC. MSC sends BSSMAP messages along with the
following messages;
Connection Indication Message
Connection Confirm Message
Data Indication Message
Unit Data Indication Message
Measurement Point

Counter ‘C20104’ increments when BSC receives the first BSSMAP


message from the MSC.

C20105
Definition

Number of downlink BSSMAP messages received with error


Description

Counter ‘C20105’ represents the number of BSSMAP messages that


MSC sends to BSC, contains error. Error such as:
L3 message length is 0
Miss match between BSSMAP and L3 messages length
Decoding error
Message type error.
Measurement Point

Counter ‘C20105’ increments when BSC receives the first BSSMAP


message containing error.

BSSMAP Message Counters


BSSMAP include all the messages exchanges between BSC and MSC that
are actually processed by the BSC. Examples are Paging, Handover and
Reset messages.

Table 26 represents all the BSSMAP Message Counters over the A-


interface.

Confidential and Proprietary Information of ZTE CORPORATION 289


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

TABLE 26 BSSMAP MESSAGE COUNTERS

Counter No. Counter Definition


C20001 Number of ASSIGNMENT REQUEST messages
C20002 Number of ASSIGNMENT COMPLETE messages
C20003 Number of ASSIGNMENT FAILURE messages
C20004 Number of HANDOVER REQUEST messages
C20005 Number of HANDOVER REQUIRED messages
C20006 Number of HANDOVER COMMAND messages
C20007 Number of HANDOVER REQUEST ACK messages
C20008 Number of HANDOVER COMPLETE messages
C20009 Number of HANDOVER FAILURE messages
C20010 Number of HANDOVER PERFORMED messages
C20011 Number of HANDOVER REQUIRED REJECT messages
C20012 Number of HANDOVER DETECT messages
C20013 Number of CLEAR COMMAND messages
C20014 Number of CLEAR COMPLETE messages
C20015 Number of CLEAR REQUEST messages
C20016 Number of SAPI “N” REJECT messages
C20017 Number of uplink CONFUSION messages
C20018 Number of downlink CONFUSION messages
C20019 Number of SUSPEND messages
C20020 Number of RESUME messages
C20021 Number of MSC INVOKE TRACE messages
C20022 Number of BSS INVOKE TRACE messages
C20023 Number of CHANGE CIRCUIT messages
C20024 Number of CHANGE CIRCUIT ACKNOWLEDGE messages
C20025 Number of CIPHER MODE COMMAND messages
C20026 Number of CIPHER MODE COMPLETE messages
C20027 Number of CIPHER MODE REJECT messages
C20028 Number of CLASSMARK UPDATE messages
C20029 Number of QUEUING INDICATION messages
C20030 Number of COMPLETE LAYER 3 INFORMATION messages
C20031 Number of CLASSMARK REQUEST messages
C20032 Number of HANDOVER CANDIDATE ENQUIRE messages
C20033 Number of HANDOVER CANDIDATE RESPONSE messages
C20034 Number of uplink RESET messages
C20035 Number of downlink RESET messages
C20036 Number of uplink RESET ACKNOWLEDGE messages

290 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 17 - A-interface Signal Measurement

Counter No. Counter Definition


C20037 Number of downlink RESET ACKNOWLEDGE messages
C20038 Number of uplink OVERLOAD messages
C20039 Number of downlink OVERLOAD messages
C20040 Number of uplink RESET CIRCUIT messages
C20041 Number of downlink RESET CIRCUIT messages
C20042 Number of uplink RESET CIRCUIT ACK messages
C20043 Number of downlink RESET CIRCUIT ACK messages
C20044 Number of uplink BLOCK messages
C20045 Number of downlink BLOCK messages
C20046 Number of uplink BLOCKING ACKNOWLEDGE messages
C20047 Number of downlink BLOCKING ACKNOWLEDGE messages
C20048 Number of uplink UNBLOCK messages
C20049 Number of downlink UNBLOCK messages
C20050 Number of uplink UNBLOCKING ACKNOWLEDGE messages
C20051 Number of downlink UNBLOCKING ACKNOWLEDGE messages
C20052 Number of uplink CIRCUIT GROUP BLOCK messages
C20053 Number of downlink CIRCUIT GROUP BLOCK messages
Number of uplink CIRCUIT GROUP BLOCKING ACKNOWLEDGE
C20054
messages
C20065 Number of uplink LOAD INDICATION messages
C20066 Number of downlink LOAD INDICATION messages

Confidential and Proprietary Information of ZTE CORPORATION 291


This Page is intentionally blank

292 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 18

A- Interface Service
Measurement

This chapter covers the following topics:

SMM Assignment Counters


SMM Handover Counters
SMM Call Drop Counters

SMM Assignment Counters


SMM Assignment Counters provide statistics for the successful and failed
assignments due to different causes, but actually processed by SMM.

Assignment Process
Assignment process involves following steps:
1. MSC sends ‘Assignment Request’ message to the SMM through A-
interface.
2. SMM checks the circuit status and searches database for the available
circuit.
3. SMM also checks the circuit attributes such as circuit rate and voice
version.
4. SMM sends ‘Assignment Request’ message to the RMM.
5. RMM sends ‘Assignment Command’ message to the MS.
6. MS sends ‘Assignment Complete’ message to MSC if MS successfully
acquires the assignment.
FIGURE 20 illustrates the Assignment Process.

Confidential and Proprietary Information of ZTE CORPORATION 293


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

FIGURE 20 - SMM ASSIGNMENT PROCESS

MS RMM SMM MSC


Assignment Request

Assignment Command Assignment Request

Assignment Complete
Assignment Complete

Assignment Complete

TABLE 27 SMM ASSIGNMENT COUNTERS

Counter No. Counter Definition


C20301 Number of Assignment attempts
C20302 Number of unsuccessful assignments due to Circuit block
C20303 Number of unsuccessful assignments due to Circuit Group Mismatch
C20304 Number of unsuccessful assignments due to timeout
C20305 Number of unsuccessful assignments due to the other causes.

SMM Assignment Counters Explanation


C20301
Definition

Number of assignment attempts


Description

Counter ‘C20301’ represents the number of ‘Assignment Request’


messages that BSC receives from the MSC, through A-interface.
Measurement point

Counter ‘C20301’ increments when BSC receives the first ‘Assignment


Request’ message from the MSC.

C20302
Definition

Number of unsuccessful assignments due to Circuit block


Description

294 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 18 - A- Interface Service Measurement

BSC sends ‘Assignment Fail’ messages to MSC if the requested circuit


is block, hence assignment fails.
Measurement point
Counter ‘C20302’ increments when BSC sends first ‘Assignment Fail’
message to MSC due to the block circuit.

C20303
Definition

Number of unsuccessful assignments due to Circuit Group Mismatch


Description
MSC sends ‘Assignment Request’ message to the BSC, through A-
interface. BSC in reply sends ‘Assignment Fail’ message to the MSC if
there is a mismatch between required circuit attributes and BSC
configuration. Circuit attributes such as Type, Voice Version and Rate.
Measurement point

Counter ‘C20303’ increments when BSC sends the first ‘Assignment


Fail’ message to the MSC due to Circuit Group Mismatch.

C20304
Definition

Number of unsuccessful assignments due to the timeout


Description
When BSC receives ‘Assignment Request’ message:
1. SMM sends ‘Assignment Request’ message to RMM
2. SMM initiates timer T1 and waits for RMM response
3. T1 expires if there is no response from RMM within specified time
4. SMM returns ‘Assignment Fail’ message to MSC.
FIGURE 21 illustrates the Assignment Failure Process within BSS.

Confidential and Proprietary Information of ZTE CORPORATION 295


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

FIGURE 21 - ASSIGNMENT FAILURES PROCESS

RRM SCM MSC

Assignment Request
Assignment Request
Set T1

Assignment Complete
Stop T1
Assignment Complete

Assignment Request
Assignment Request
Set T1

Assignment Failure
T1 Timeout
A

Counter ‘C20304’ represents the number of times BSC sends


‘Assignment Fail’ message to the MSC, specifically due to the timeout.
Measurement point

Counter ‘C20304’ increments when the timer T1 expires. In FIGURE 21,


point ‘A’ represents the measurement point.

C20305
Definition

Number of unsuccessful assignments due to the other causes


Description

MSC sends ‘Assignment Request’ message to the BSC, through A-


interface. Assignment becomes unsuccessful if message contains errors
such as: voice version, rate and field error.
Measurement point

Counter ‘C20305’ increments when BSC sends the first ‘Assignment


Fail’ message to the MSC due to other causes.

SMM Handover in Counters


SMM Handover Counters provide statistics for the successful and failed
handover due to the different causes, but are actually processed by the
SMM.

296 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 18 - A- Interface Service Measurement

SMM Handover in Process


Handover-In process involves the following steps:
1. MSC sends ‘Handover Request’ message to the SMM through A-
interface.
2. SMM checks the circuit status and searches database for the available
circuit.
3. SMM also checks the circuit attributes such as circuit rate and voice
version.
4. SMM sends ‘Handover Request’ message to the RMM.
5. RMM sends ‘Handover Command’ message to the MS.
6. MS sends ‘Handover Complete’ message all the way back to MSC if MS
successfully acquires the channel.

FIGURE 22 - HANDOVER PROCESS

MS RMM SMM MSC

Handover Request
Handover Request
Handover Command
Handover Complete Handover Complete

Handover Complete

Table 28 represents SMM Handover Counters and their definition.

TABLE 28 SMM HANDOVER COUNTERS

Counter No. Counter Definition


C20401 Number of handover in attempts
C20402 Number of unsuccessful handover ins due to Circuit block
C20403 Number of unsuccessful handover ins due to Circuit Group Mismatch
C20404 Number of unsuccessful handover ins due to the timeout
C20405 Number of unsuccessful handover ins due to the other causes.

Handover in Counters Explanation


C20401
Definition

Number of Handover in attempts

Confidential and Proprietary Information of ZTE CORPORATION 297


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Description

Counter ‘C20401’ represents the number of ‘Handover Request’


messages that BSC receives from the MSC, through A-interface.
Measurement point

Counter ‘C20401’ increments when BSC receives the first ‘Handover


Request’ message from the MSC.

C20402
Definition

Number of unsuccessful handover-ins due to Circuit block


Description

MSC sends ‘Handover Request’ message to BSC through A-interface.


BSC searches for the required circuit in database. BSC sends ‘Handover
Fail’ message to MSC, If the required circuit is blocked,
Measurement point

Counter ‘C20402’ increments when BSC sends first ‘Handover Fail’


message to MSC due to the block circuit.

C20403
Definition

Number of unsuccessful handover-ins due to Circuit Group Mismatch


Description

MSC sends ‘Handover Request’ message to the BSC, through A-


interface. BSC searches for the required circuit in database. BSC sends
‘Handover Fail’ message to MSC, if there is a mismatch between
required circuit attributes and BSC configuration. Circuit attributes
such as Type, Voice Version and Rate.
Measurement point

Counter ‘C20403’ increments when BSC sends first ‘Handover Fail’


message to MSC due to ‘Circuit Group Mismatch’.

C20404
Definition

Number of unsuccessful handover-ins due to the timeout


Description

When BSC receives ‘Handover Request’ message:


1. SMM sends ‘Handover Request’ message to RMM
2. SMM initiates timer T4 and waits for the RMM response

298 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 18 - A- Interface Service Measurement

3. Timer T4 expires if there is no response from RMM within the specified


time
4. SMM returns ‘Handover Fail’ message to MSC.
FIGURE 23 illustrates the Handover Fail process.

FIGURE 23 - HANDOVER FAILURE PROCESS

RRM SCM MSC

handover Request
handover Request
Set T4

Handover Complete
Stop T4
Handover Complete

Handover Request
Handover Request
Set T4

Handover Failure
T4 Tim eout
A

Counter ‘C20404’ represents the number of ‘Handover Fail’ messages


that BSC sends to MSC due to timeout.
Measurement Point

Counter increments when the timer T4 expires. In FIGURE 23, point ‘A’
represents the measurement point.

C20405
Definition

Number of unsuccessful handover-ins due to the other causes


Description

MSC sends ‘Handover Request’ message to the BSC, through A-


interface. Handover fails if message contains errors such as: voice
version, rate and field error.
Measurement Point

Counter ‘C20405’ increments when BSC sends the first ‘Handover Fail’
message to MSC due to the other causes.

Confidential and Proprietary Information of ZTE CORPORATION 299


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

SMM Call Drop Counters


SMM Call Drop counters provide statistics for:

Abnormal call drops


Circuit Release requests from RMM
SCCP link disconnection
Disconnection of SMM and RMM communication
Table 29 represents all SMM Call Drop counters

TABLE 29 SMM CALL DROP COUNTERS

Counter No. Counter Definition


C20501 Number of RMM requests for the circuit release.
C20502 Number of abnormal SCCP link disconnections
C20503 Number of call drops due to timeout
C20504 Number of call drops due the other causes

Call Drop Counters Explanation


C20501
Definition

Number of RMM requests for the circuit release.


Description
RMM originates the circuit release due to poor radio link level and
quality. Counter ‘C20501’ represents the number of RMM requests for
circuit release.
Measurement point

Counter increments when SMM receives first ‘Clear Request’ message


from the RMM.

C20502
Definition

Number of abnormal SCCP link disconnections


Description

Counter ’C20502’ represents the number of call drops due to abnormal


SCCP link disconnections.

300 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 18 - A- Interface Service Measurement

Measurement point

Counter increments when SMM receives first ‘SCCP DISCONNECT


INDICATION’ message.

C20503
Definition

Number of call drops due to timeout


Description

Timer initiates when SMM request RMM services. Call drops if RMM do
not respond within the specific time. Following cases may result in a
call drop.
SMM and RMM periodically shake hand with each other to refresh
the link. SMM sends status query to the RMM. SMM sets the timer
(T12) and waits for the RMM response. Timer (T12) expires if SMM
do not receive any response from RMM within the specific time,
hence call drops.
SMM send ‘Assignment Request’ message to RMM. SMM sets the
timer (T1) and waits for RMM response. Timer (T1) expires if SMM
do not receive any response from RMM, hence call drops.
SMM sends ‘Handover Request’ message to RMM, during the
handover-out process. SMM sets the timer (T8) and waits for RMM
response. Timer (T8) expires if SMM do not receive any response
from RMM, hence call drops.
SMM sends ‘Handover Request’ message to RMM, during the
handover-in process. SMM sets the timer (T4) and waits for RMM
response. Timer (T4) expires if SMM do not receive any response
from RMM, hence call drops.
Counter ‘C20503’ represents the number of call drops due to the
timeout.
Measurement Point

Counter ‘C20503’ increments when:


T12 expires
T1 expires
T8 expires.
T4 expires

C20504
Definition

Number of call drops due the other causes


Description

Call Drops due to the following causes:

Confidential and Proprietary Information of ZTE CORPORATION 301


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

SMM receives ‘Handover Complete’ message containing errors


SMM receives ‘Assignment Fail’ or ‘Handover Fail’ message due to
no return of the old channel.
SMM receives ‘Change Circuit’ message appears, but circuit
application fails.
SMM receives ‘Assignment Complete’ message containing errors
Measurement Point

Counter ‘C20504’ increments when SMM receives:


‘Handover Complete’ message containing errors.
‘Assignment Fail’ or ‘Handover Fail’ message due to no return of the
old channel.
‘Change Circuit’ message, but circuit application fails.
‘Assignment Complete’ message containing errors.

302 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 19

SCCP Connection
Measurement

This Chapter covers the following topics:

SCCP Connection Counters

SCCP Connection Counters


SCCP Connection Counters provide statistics for SCCP messages that are
used to setup an SCCP connection. At the beginning of an SCCP
connection setup, either MSC or BSC can initiate the setup process. The
SCCP link setup process is shown in FIGURE 24.

FIGURE 24 - SCCP CONNECTION SETUP

BSC MSC BSC MSC

Connection Request Connection Request

A E

Connection Confirm Connection Confirm

B F
5(a) 5(b)

BSC may be the first one to send ‘Connection Request’ message to MSC,
as shown in Fig 5(a). MSC in reply may send ‘Connection Confirm’
message as an acknowledgement. Similar process occurs if MSC initiates
the SCCP connection setup, as illustrated in FIGURE 24 (b).

SCCP Message Counters are listed in Table 30.

Confidential and Proprietary Information of ZTE CORPORATION 303


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

TABLE 30 SCCP CONNECTION COUNTERS

Counter No. Counter Definition


C20201 Number of BSC originated SCCP Connection attempts
C20202 Number of BSC originated successful SCCP Connections
Number of BSC originated unsuccessful SCCP Connections due to
C20203
timeout
C20204 Number of negative replies for SCCP connection request
C20205 Number of MSC originated SCCP Connection Requests
C20206 Number of MSC originated successful SCCP Connections

SCCP Connection Counters Explanation


C20201
Definition

Number of BSC originated SCCP Connection attempts


Description

BSC sends ‘Connection Request’ message to establish an SCCP


connection with MSC. Counter ‘C20201’ represents number of
‘Connection Request’ messages that BSC sends to MSC.
Measurement point

Counter ‘C20201’ increments when BSC sends first ‘Connection


Request’ message to the MSC (Point ‘A’ in FIGURE 24).

C20202
Definition
Number of BSC originated successful SCCP Connections

Description

BSC sends ‘Connection Request’ message to establish an SCCP


connection with MSC. MSC in reply sends ‘Connection Confirm’
message to the BSC. Counter ‘C20202’ represents the number of
‘Connection Confirm’ messages that BSC receives from MSC.
Measurement point

Counter ‘C20202’ increments when BSC receives first ‘Connection


Request’ message from the MSC (point ‘B’ in FIGURE 24).

C20203
Definition

Number of BSC originated unsuccessful SCCP Connections due to


timeout

304 Confidential and Proprietary Information of ZTE CORPORATION


Chapter19 - A- Interface Service Measurement

Description
BSC sends ‘Connection Request’ message to establish an SCCP
connection with MSC. On the same time, Timer ‘T9105’ is set on and
BSC waits for the MSC response. Timer ‘T9105’ expires if MSC do not
respond within the specific time. As a result an SCCP connection setup
fails.
Counter ‘C20203’ represents the number of unsuccessful BSC attempts
to establish an SCCP connection with the MSC due to timeout.
Measurement point

Counter ‘C20203’ increments at the point when Timer ‘T9105’ expires


(Point F in FIGURE 25).

FIGURE 25 - TIME DELAY SCENARIO IN SCCP CONNECTION SETUP

BSC MSC

Connection Request
Set T9105

T 9105 Timeout
F

C20204
Definition

Number of negative replies for SCCP connection request


Description
Counter ‘C20204’ represents the number of ‘Connection Refused’
messages that BSC receives from MSC, in reply to the SCCP
Connection Request.
Measurement point

Counter ‘C20204’ increments when BSC receives first ‘Connection


Refused’ message from MSC (Point ‘G’ in FIGURE 25).

Confidential and Proprietary Information of ZTE CORPORATION 305


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

FIGURE 26 - SCCP ‘CONNECTION REFUSED’ FROM MSC

BSC MSC

Connection Request

Connection Refused

C20205
Definition

Number of MSC originated SCCP Connection Requests

Description

MSC sends ‘Connection Request’ message to establish an SCCP


connection with BSC. Counter ‘C20205’ represents the number of
‘Connection Request’ messages that BSC receives from MSC.
Measurement point

Counter ‘C20205’ increments when BSC receives first ‘Connection


Request’ message to the MSC (Point ‘E’ in FIGURE 24).

C20206
Definition
Number of MSC originated successful SCCP Connections
Description

BSC sends ‘Connection Confirm’ messages to MSC, if SCCP connection


setup becomes successful.
Measurement point

Counter ‘C20206’ increments when BSC sends first ‘Connection


Confirm’ message to the MSC (point ‘F’ in FIGURE 24).

306 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 20

Terrestrial Resources
Measurement

This chapter covers the following topic:

Trunk Circuit Counters

Trunk Circuit Counters


Trunk Circuit counters provide statistics for the all the BSC trunk circuits.
Table 31 lists all the Trunk Circuit Counters.

TABLE 31 TRUNK CIRCUIT COUNTERS

Counter No. Counter Definition


C20601 Mean number of available trunk circuits
C20602 Mean number of unavailable trunk circuits
C20603 Maximum number of busy trunk circuits
C20604 Total busy time of trunk circuit
C20605 Total congestion time of trunk circuit

Trunk Circuit Counters Explanation


C20601
Definition

Mean number of available trunk circuits


Description

Counter ‘C20601’ represents the mean number of trunk circuits that


are normally available to use.

Confidential and Proprietary Information of ZTE CORPORATION 307


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Measurement point
System calculates the mean number of available trunk circuits by
timely checking the circuit status and querying the circuit database.

C20602
Definition

Mean number of unavailable trunk circuits


Description

Counter ‘C20602’ represents the mean number of trunk circuits that


are normally unavailable to use. Unavailable trunk circuits can be;
Occupied
Blocked
Measurement point

System calculates the mean number of available trunk circuits by


timely checking the circuit status and querying the circuit database.

C20603
Definition

Maximum number of busy trunk circuits


Description

Counter ‘C20603’ represents the maximum number of occupied trunk


circuits during measurement cycle. System keeps the record of
occupied trunk circuit quantity during the measurement cycle. If the
occupied trunk circuit quantity exceeds the value of this counter,
system records the new value in this counter.
Measurement point

Counter ‘C20603’ increments on three time instances;


When system successfully occupies the circuit
Before system has to releases the circuit
During the time measurement cycle

C20604
Definition

Total busy time of the trunk circuits


Explanation
Counter ‘C20604’ represents the total busy time of all the trunk circuit
during measurement cycle.
System represents the busy status of the trunk circuit in a separate
variable ‘n’. Each time system occupies the circuit, ‘n’ increments by

308 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 20 - A- Interface Service Measurement

one. Each time system releases the trunk circuit, ‘n’ decrements by
one.
The measurement calculation process is shown in FIGURE 27.

FIGURE 27 - TOTAL BUSY TIME FOR THE TRUNK CIRCUITS

Time Time

Trunk circuit Occupation time+ = ( current time - previous


occupy or release record time) × n
Previous record time= current time
1 added to or reduced from the ‘n’
Measurement Trunk circuit
circle occupy or release
Same as the above calculation

n = Number of times for the System to


occupy the trunk circuit

Measurement value Same as the above calculation

Calculation Formula

Total occupied Time= (Current Time – Previous Represents Time) * n


Previous Represents Time = Current time.
Where:
n: number of times system occupies the trunk circuits.
Current Time: Time instance at which system occupies the trunk
circuits.
Previous Represents Time: Time instance at which system occupied the
trunk circuit last time.
(Current Time - Previous Represents Time): occupied time for the
trunk circuits.
Another way to calculate the Total occupied time is to accumulate the
occupied period at discrete time instances, during the single
measurement cycle.
Measurement point
Total occupied time is calculated on three time instances;
When system successfully occupies the trunk circuit
Before system has to releases the trunk circuit
During the time measurement cycle

C20605
Definition
Total congestion time of trunk circuit

Confidential and Proprietary Information of ZTE CORPORATION 309


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Description
Counter ‘C20605’ represents the total time for which trunk circuit can
not be applied. When system fails to occupy the trunk circuit,
congestion mark is set on. System represents the congestion time once
the congestion mark is set on the trunk circuit in database. System
clears the congestion mark once the trunk circuit is released.
Measurement formula
If congestion mark is set on, the Total Congestion Time at this point
can be calculated as follows.
Total Congestion Time= (Release Time – Previous record congestion
Time)
Where;
Release Time: Time instance at which system releases the trunk circuit.
Previous Record Time: Time instance at which system applies for the
trunk circuit, but it unavailable due to congestion.
Another way to calculate the Total Congestion Time is to accumulate
the congestion period at discrete time instances, during the single
measurement cycle.
Measurement point
Total Congestion Time is calculated on three time instances;
When system successfully occupies the trunk circuit
Before system has to releases the trunk circuit
During the time measurement cycle

310 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 21

TRX LAPD Link Measurement

This chapter covers the following topic:

LAPD Link Counters

LAPD Link Counters


LAPD Link Counters provide statistics for the TRX LAPD board, which
transfers the signaling messages to its contiguous layers. LAPD link is the
data link layer, lies at second level in the hierarchy. System represents the
statistics when LAPD board sends or receives the messages.

Table 32 represents all the LAPD link counters.

TABLE 32 LAPD LINK COUNTERS

Counter No. Counter Definition


C30001 Number of packets transfers from MP to application layer.
C30002 Number of I-frames LAPD link sends through Abis-Interface
C30003 Number of I-frames LAPD link receives through Abis-Interface
C30004 Number of packets LAPD link receives for application layer
C30005 Total number of frames TRX LAPD Link sends on the Abis-interface
C30006 Total number of frames TRX LAPD Link receives through Abis-interface
C30007 Number of lost messages due to Buffer overflow
C30008 Number of TRX LAPD Link data frame retransmissions

Confidential and Proprietary Information of ZTE CORPORATION 311


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Counter No. Counter Definition


C30009 Number of data frame retransmission requests TRX LAPD Link receives
C30010 Number of successful TRX LAPD Link setups
C30011 Number of TRX LAPD Link disconnections
C30012 Number of LAPD protocol errors
C30013 Packet loss due to flow control

LAPD Link Counters Explanation


C30001
Definition

Number of packets transfers from MP to application layer.


Description
LAPD link receives the signaling message from MP (application layer)
and breaks it up into the packets. It then transmits all the packets on
Abis-interface (Physical layer).
Measurement point

Counter ‘C30001’ increments when TRX LAPD link sends the application
layer packet.

C30002
Definition

Number of I-frames LAPD link sends through Abis-Interface


Description

TRX LAPD link receives I-frame from the MP (Application Layer) and
breaks it up into the packets. It then transmits all the packets on Abis-
interface.
Measurement point

Counter ‘C30002’ increments when the TRX LAPD link sends I frame
through Abis-interface.

C30003
Definition

Number of I-frames LAPD link receives through Abis-Interface

312 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 21 - TRX LAPD Link Measurement

Description

TRX LAPD link receives I-frame through Abis-Interface and breaks it up


into the packets. It then transmits all the packets to MP (Layer 3).
Measurement point

Counter ‘C30003’ increments when the TRX LAPD link receives I frame
through Abis-interface.

C30004
Definition

Number of packets LAPD link receives for application layer


Description
LAPD link receives the signaling message from Abis-Interface (physical
layer) and breaks it up into the packets. LAPD Link then transmits all
the packets to MP (Application layer).
Measurement point

Counter ‘C30004’ increments when TRX LAPD link receives the


message that belongs to MP (application layer).

C30005
Definition

Total number of frames TRX LAPD Link sends on the Abis-interface


Description

Counter ‘C30005’ represents the total number of frames that TRX LAPD
link sends on the Abis-interface. Total number of frames includes all
types of LAPD frames.
Measurement point
Counter ‘C30005’ increments when the TRX LAPD link sends first frame
on the Abis-Interface.

C30006
Definition

Total number of frames TRX LAPD Link receives through Abis-interface


Description
Counter ‘C30006’ represents the total number of frames that TRX LAPD
link receives from the Abis-interface. Total number of frames includes
all types of LAPD frames.
Measurement point

Counter ‘C30006’ increments when the TRX LAPD link receives first
frame from the Abis-Interface.

Confidential and Proprietary Information of ZTE CORPORATION 313


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C30007
Definition
Number of lost messages due to Buffer overflow
Description

Each TRX LAPD card contains buffer to accumulate the messages


before send out. The buffer overflows if too many messages
accumulate in it. As a result buffer tends to loose the messages.
Counter ‘C30007’ represents the number of message loss occurs due
to buffer overflow.
Measurement point

Counter ‘C30007’ increments when message loss occurs due to buffer


overflow.

C30008
Definition

Number of TRX LAPD Link data frame retransmissions


Description

Counter ‘C30008” represents the number of data frames that LAPD link
retransmits. Sender keeps on sending the data frames until recipient
does not acknowledge the send message.
Measurement Point

Counter ‘C30008” increments when sender retransmits the data frame.

C30009
Definition

Number of data frame retransmission requests TRX LAPD Link receives


Description

Counter ‘C30009’ represents number of data frame retransmission


requests, if not received correctly on the first occasion. As a result,
sender retransmits the data frame and waits for an acknowledgement.
Measurement point
Counter ‘C30009’ increments when TRX LAPD link receives the
retransmission request.

C30010
Definition

Number of successful TRX LAPD Link setups

314 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 21 - TRX LAPD Link Measurement

Description

Counter ‘C30010’ represents the number of successful TRX LAPD Link


establishments between the two peer entities.
Measurement point

Counter ‘C30010’ increments when the TRX LAPD link is established


between the two peer entities.

C30011
Definition

Number of TRX LAPD Link disconnections


Description

Counter ‘C30011’ represents the number of TRX LAPD link


disconnections between two peer entities.
Measurement point

Counter ‘C30011’ increments when BSC detects the TRX LAPD link
disconnection.

C30012
Definition

Number of LAPD protocol errors


Description
Counter ‘C30012’ represents the number of LAPD messages containing
errors, received through Abis-interface.
Measurement point

Counter ‘C30012’ increments when LAPD link receives the message


about error in LAPD protocol through Abis-interface.

C30013
Definition

Packet loss due to flow control


Description

Counter ‘C30013’ represents the number of packet loss due to the flow
control. Flow control is to reduce the load on CPU.
Measurement point
Counter ‘C30013’ increments when packet loss due to flow control.

Confidential and Proprietary Information of ZTE CORPORATION 315


This page is intentionally blank.

316 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 22

Processor Load Measurement

Processor Load Measurement provide statistics for CPU load, memory


consumption, service load and file system load in SMM and RMM. The
statistical units of measurement are RMM and SMM. Measurement usually
occurs after every five minutes.

This chapter covers the following topics:

RMM Load Counters


Service Load Counters
Usability Measurement Counters
SMM Load Counters
File System Load Counters

RMM Load Counters


RMM Load Counters provide statistics such as CPU load and memory
consumption for RMM.

Table 33 lists RMM Load Counters

TABLE 33 RMM LOAD COUNTERS

Counter No. Definition


C90101 Average load of the processor
C90102 Peak value of the processor load
C90103 Average value of the memory resource utilization
C90104 Peak value of the memory resource utilization

Confidential and Proprietary Information of ZTE CORPORATION 317


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

RMM Load Counters Explanation


C90101
Definition

Average load of the processor


Description

System collects the samples of the CPU load for RMM, after every ten
seconds. System then calculates the average of the collected sample
values (after every five minutes). This average value represents the
average load on the processor.
Counter ‘C90101’ represents the average CPU load for RMM. System
regularly updates the counter every five minutes.
Measurement Point

Counter ‘C90101’ increments when system calculates the average


value after every five minutes.

C90102
Definition

Peak value of the processor load


Description

System collects the samples of the CPU load for RMM after every ten
seconds. System then calculates the average of the collected sample
values (after every five minutes). System compares the calculated
average value with the maximum value of the CPU load on the
represents. If the average value exceeds the previous represents value,
system represents the new peak value in the counter.
Counter ‘C90102’ represents the peak value of the CPU load for RMM.
Measurement Point

Counter ‘C90102’ increments when system selects the new peak value
of the CPU load for RMM.

C90103
Definition

Average value of the memory resource utilization


Description

Not in use
Measurement Point

Not in use

318 Confidential and Proprietary Information of ZTE CORPORATION


Chapter22 - Processor Load Measurement

C90104
Definition

Peak value of the memory resource utilization


Description

Not in use
Measurement Point

Not in use

Service Load Counter


Service Load Counters provide statistics for the number of service calls for
SMM and RMM. Only single counter below identifies the service load on
RMM and SMM.

Table 34 represents the Service Load Counter.

TABLE 34 SERVICE LOAD COUNTER

Counter No. Definition


C90201 Number of Voice calls service for SMM and RMM.

Service Load Counter Explanation


C90201
Definition

Number of Voice Calls service for SMM and RMM.


Description

Counter ‘C90201’ represents the number of voice calls that SMM and
RMM receives.
Voice calls service for SMM at AIS instance:
SMM receives ‘Establish Indication’ message from RMM.
SMM receives ‘Handover Request’ message through A-interface.
Service calls for RMM at RMS instance:
RMM receives ‘Assignment Required’ message from BTS.
RMM receives ‘Handover Request’ message from one or more RMM.

Confidential and Proprietary Information of ZTE CORPORATION 319


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Measurement Point

Counter ‘C90201 increments when:


SMM receives ‘Establish Indication’ and ‘Handover Request’
messages.
RMM receives ‘Assignment Required’ and ‘Handover Request’
messages.

Usability Measurement Counter


Only single counter in the Table 35 below represents the usability
measurement counter.

TABLE 35 USABILITY MEASUREMENT COUNTER

Counter No. Definition


C90301 Number of unit restarts

Usability Measurement Counter


Explanation
C90301
Definition

Number of unit restarts


Description

Counter ‘C90301’ represents the number of times for unit to restart.


Measurement Point

Counter ‘C90301’ increments when system receives HDLC


disconnection message.

SMM Load Counters


SMM Load Counters provide statistics for CPU load and memory
consumption for SMM. Description of the following counters is same as
‘RMM Load Counters’. The only difference is that the following counters
provide statistics for SMM.

Table 36 below lists all the SMM load counters.

320 Confidential and Proprietary Information of ZTE CORPORATION


Chapter22 - Processor Load Measurement

TABLE 36 SMM LOAD COUNTERS

Counter No. Definition


C90401 Average load of the processor
C90402 Peak value of the processor load
C90403 Average value of the memory resource utilization
C90404 Peak value of the memory resource utilization

SMM Load Counters Explanation


Refer to Section ‘RMM Load Counters’.

File System Load Counters


File System Load Counters provide statistics for the system’s read or write
frequency on the hard disk for both RMM and SMM. These counters also
represent the alarm file and performance measurement file.

TABLE 37 FILE SYSTEM LOAD COUNTERS

Counter No. Definition


C90501 Number of file opening
C90502 Number of failed file opening
C90503 Number of file reading
C90504 Number of failed file reading
C90505 Number of file bytes read
C90506 Number of file writing
C90507 Number of failed file writing
C90508 Number of file bytes written
C90509 Number of file closing
C90510 Number of failed file closing
C90511 Number of hard disk goes into the dormant state.

Confidential and Proprietary Information of ZTE CORPORATION 321


This page is intentionally blank.

322 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 23

Q3 Module Measurement

This chapter covers the following topics:

Q3 Module Measurement Counters.

Q3 Module Counters
Q3 module measurement is an analogy for BSC measurement. Statistics
involve assignment, handover and CPU load. The statistics is mainly for
RMM. For the SMM, the statistics only involves the CPU load.

Table 38 lists all the Q3 Module Measurement Counters

TABLE 38 Q3 MODULE MEASUREMENT COUNTERS

Counter No. Counter Definition


C11801 Number of attempts for immediate assignment.
C11802 Number of successful channel allocations
C11803 Number of successful handovers (intra-cell)
C11804 Number of unsuccessful handovers (intra-cell)
C11805 Number of successful handovers (intra-BSC handover)
Number of successful handovers due to better uplink quality (inter-cell
C11806
handovers).
Number of successful handovers due to better uplink strength (inter-cell
C11807
handovers).
Number of successful handovers due to better downlink quality (inter-cell
C11808
handovers).

Confidential and Proprietary Information of ZTE CORPORATION 323


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Counter No. Counter Definition


Number of successful handovers due to better downlink strength (inter-cell
C11809
handovers).
C11810 Number of successful handovers (inter-cell) due to large TA.
Number of successful handovers due to the better target cell (inter-cell
C11811
handovers).
Number of successfully handovers due to the OAM interference (inter-cell
C11812
handovers).
C11813 Number of handovers due to locating retry (inter-cell handover)
Number of return of the old channel due to handover failure (inter-cell
C11814
handovers).
C11815 Number of call losses in case of internal handover
C11816 Average load of the processor
C11817 Peak value of the processor load
C11818 Time instance at which CPU load meets or exceeds the peak value
C11819 Time instance at which CPU load meets or exceeds the peak value

Q3 Module Counters Explanation


C11801
Definition

Number of attempts for immediate assignment


Description

Counter ‘C11801’ represents the number of RMM attempts for an


immediate assignment, when BSC receives ‘Channel Required’
message from BTS.
Measurement Point
Counter ‘C11801’ increments when BSC receives ‘Channel Required’
message from BTS.

C11802
Definition

Number of successful channel allocations


Description

When RMM receives ‘Establish Indication’ message from BTS, it


indicates that BSC successfully allocates the channel. Counter ‘C11801’
represents the number of successes for BSC in allocating the channel.

324 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 23 - Q3 Module Measurement

Measurement Point
Counter ‘C11801’ increments when RMM receives ‘Establish Indication’
message.

C11803
Definition

Number of successful handovers (intra-cell)


Description
In case of successful handover (intra-cell), MS sends ‘Assignment
Complete’ message to MSC. Reception of ‘Assignment Complete’
message on the new channel indicates that the handover is successful.
FIGURE 28 illustrates the successful intra-cell handover process.
Counter ‘C11802’ represents the number of successful intra-cell
handovers
Measurement Point
Counter ‘C11802’ increments when BSC receives ‘Assignment
Complete’ message from the MS.

FIGURE 28 - SUCCESSFUL INTRA CELL HANDOVER PROCESS

MS RMM

Assignment Command

Assignment Complete
(New channel)

C11804
Definition

Number of unsuccessful handovers (intra-cell)


Description
When the handover (intra-cell) fails, MS sends ‘Assignment Fail’
message on the old channel to MSC. FIGURE 29 illustrates the
unsuccessful intra-cell handover process.
Counter ‘C11804’ represents the number of unsuccessful intra-cell
handovers.
Measurement Point
Counter ‘C11804’ increments when BSC receives ‘Assignment Fail’
message from the MS.

Confidential and Proprietary Information of ZTE CORPORATION 325


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

FIGURE 29 - INTRA-CELLS HANDOVER FILURE PROCESS

MS RMM

Assignment Command

Assignment Failure
(Old channel)

C11805
Definition

Number of successful handovers (intra-BSC handover)


Description

When BSC successfully handovers the MS to another cell, it receives


‘Handover Complete’ message from the MS. MS sends ‘Handover
Complete’ message to the BSC, on the channel assigned to MS in the
new cell. FIGURE 30 illustrates the successful inter-cell handover
process.
Counter ‘C11805’ represents the number of successful inter-cell
handovers
Measurement Point
Counter ‘C11805’ increments when BSC receives ‘Handover Complete’
message from the MS.

FIGURE 30 - SUCCESSFUL INTER-CELL HANDOVER PROCESS

MS RMM

Handover Command

Handover Complete
(New channel)

326 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 23 - Q3 Module Measurement

C11806
Definition

Number of successful handovers due to better uplink quality (inter-cell


handovers)
Description

Counter ‘C11806’ represents the number of successful inter-cell


handovers to the target cell. Cause of handover is the better uplink
quality in the target cell.
Measurement Point

Counter ‘C11806’ increments when BSC receives ‘Handover Complete’


message from MS on the new channel.

C11807
Definition

Number of successful handovers due to better uplink strength (inter-


cell handovers)
Description

Counter ‘C11807’ represents the number of successful inter-cell


handovers to the target cell. Cause of handover is the better uplink
strength in the target cell.
Measurement Point

Counter ‘C11807’ increments when BSC receives ‘Handover Complete’


message from MS on the new channel.

C11808
Definition

Number of successful handovers due to better downlink quality (inter-


cell handovers)
Description

Counter ‘C11808’ represents the number of successful inter-cell


handovers to the target cell. Cause of handover is the better downlink
quality in the target cell.
Measurement Point

Counter ‘C11808’ increments when BSC receives ‘Handover Complete’


message from MS on the new channel.

Confidential and Proprietary Information of ZTE CORPORATION 327


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C11809
Definition

Number of successful handovers due to better downlink strength


(inter-cell handovers)
Description

Counter ‘C11809’ represents the number of successful inter-cell


handovers to the target cell. Cause for handover is the better downlink
strength in the target cell.
Measurement Point

Counter ‘C11809’ increments when BSC receives ‘Handover Complete’


message from MS on the new channel.

C11810
Definition

Number of successful handovers (inter-cell) due to large TA


Description

Counter ‘C11810’ represents the number of successfully inter-cell


handovers to the target cell. Cause for handover is the large distance
of MS with the BTS in the serving cell. At the large distance MS may
not receive desired signal strength, therefore handover occurs.
Measurement Point

Counter ‘C11810’ increments when BSC receives ‘Handover Complete’


message from MS on the new channel.

C11811
Definition

Number of successful handovers due to the better target cell (inter-cell


handovers).
Description

Counter ‘C11811’ represents the number of successful inter-cell


handovers to the target cell. Cause for handover is the better signal
strength in the target cell.
Measurement Point

Counter increments when BSC receives ‘Handover Complete’ message


from MS on the new channel.

328 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 23 - Q3 Module Measurement

C11812
Definition

Number of successful handovers due to the OAM interference (inter-


cell handovers)
Description

Counter ‘C11812’ represents the number of successful inter-cell


handovers to the target cell. Cause for handover is the OAM
interference. Handover occurs due to operation and maintenance
causes.
Measurement Point

Counter ‘C11812’ increments when BSC receives ‘Handover Complete’


message from MS on the new channel.

C11813
Definition

Numbers of successful handovers due to locating retry (inter-cell


handover)
Description

Counter ‘C11813’ represents the number of successful inter-cell


handovers to the target cell. Cause for handover is the locating retry.
Measurement Point

Counter ‘C11813’ increments when BSC receives ‘Handover Complete’


message from MS on the new channel.

C11814
Definition

Number of returns of the old channel due to handover failure (inter-cell


handovers)
Description

Counter ‘C11814’ represents the number of BSC fails to handover the


MS to the target cell. MS sends ‘Handover Fail’ message on the old
channel to BSC, if handover fails. FIGURE 31 illustrates the inter-cell
handover failure process.
Measurement Point

Counter ‘C11814’ increments when BSC receives ‘Handover Fail’


message from MS on the old channel.

Confidential and Proprietary Information of ZTE CORPORATION 329


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

FIGURE 31 - INTER-CELL HANDOVER FAILURE PROCESS

MS RMM

Handover Command

Handover Failure
(Old channel)

C11815
Definition

Number of call losses in case of internal handover


Description

Call loss occurs if BSC do not receive the following messages within
specified time:
‘Assignment Complete’ message on the new channel or ‘Assignment
Fail’ message on the old channel in case of intra-cell handover.
‘Handover Complete’ message on the new channel or ‘Handover
Fail’ message on the old channel in case of intra-BSC handover.
Measurement Point
Counter ‘C11815’ increments when RMM receives the T3107 overflow
and T3103 overflow messages.

C11816
Definition

Average load of the processor


Description

System collects the samples of the CPU load for RMM, after every ten
seconds. System calculates the average of the collected sample values
after every five minutes. This average value represents the average
load on the processor.
Counter ‘C11816’ represents the average CPU load for RMM. System
regularly updates the counter every five minutes.
Measurement Point

Counter ‘C11816’ increments when system calculates the average


value after every five minutes.

330 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 23 - Q3 Module Measurement

Calculation Formula
C11816 = C90101.

C11817
Definition

Peak value of the processor load


Description

System collects the samples of the CPU load for RMM after every ten
seconds. System then calculates the average of the collected sample
values (after every five minutes). System compares the calculated
average value with the maximum value of the CPU load on the record.
If the average value exceeds the previous represents value, system
represents the new peak value in the counter.
Counter ‘C11817’ represents the peak value of the CPU load for RMM.
Measurement Point

Counter ‘C11817’ increments when system selects the new peak value
of the CPU load for RMM.
Calculation Formula

C11817 = C90102.

C11818
Definition

Time instance at which CPU load meets or exceeds the peak value
Description

Counter ‘C11818’ represents the time instance when CPU load meets
or exceeds the peak represents value (85%).
Measurement Point

Counter ‘C11818’ increments when the CPU load meets or exceeds the
peak represents value, for the first time.

C11819
Definition

Time instance at which CPU load meets or exceeds the peak value
Description

Counter ‘C11819’ represents the total time in which CPU load meets or
exceeds the represents peak value (85%).

Confidential and Proprietary Information of ZTE CORPORATION 331


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Measurement Point

During the sampling process, if CPU load meets or exceeds the peak
value (85%), counter ‘C11819’ adds all the preceding time intervals.

332 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 24

Q3 Cell and BTS Measurement

This Chapter covers the following topics:

Q3 Cell and BTS Counters

Q3 Cell and BTS Counters


This chapter introduces the Q3 Cell and Q3 BTS Measurement Counters.
These counters provide statistics for received signal level, received signal
quality and call distance. Counters represent the measurements of all the
frequency TRXs in a cell.

For the counters of Q3 cell BTS measurement, refer to Section. The


counter values are sum of the corresponding values of Counters C00017 ~
C00028 by cell. For the measurement mechanisms and measurement
points, refer to the corresponding counter in Section.

Table 39 lists all the Q3 Cell Measurement Counters.

TABLE 39 Q3 CELL MEASUREMENT COUNTERS

Counter No. Description


C02001 Total value of each result of regular scanning of MS utilization power
C02002 Number of regular scanning and sampling of MS utilization power
C02003 Total value of each result of regular scanning of BS utilization power
C02004 Number of regular scanning and sampling of BS utilization power
C02005 Total value of each result of regular scanning of downlink signal level
C02006 Number of regular scanning and sampling of downlink signal level
C02007 Total value of each result of regular scanning of uplink signal level
C02008 Number of regular scanning and sampling of uplink signal level
C02009 Total value of each result of regular scanning of downlink signal quality
C02010 Number of regular scanning and sampling of downlink signal quality
C02011 Total value of each result of regular scanning of uplink signal quality
C02012 Number of regular scanning and sampling of uplink signal quality

Confidential and Proprietary Information of ZTE CORPORATION 333


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Counter No. Description


C02013 Total value of each result of call distance statistics
C02014 Number of call distance sampling

334 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 25

Adjacent Cell Handover


Measurement

This chapter introduces the measurement counters for handover between


the specified cells and their adjacent cells. These counters provide
statistics for both Intra-BSC handovers and MSC-controlled handovers.

This Chapter covers the following topics:

Adjacent Cell Handover Counters

Adjacent Cell Handover Counters


Handover Measurement Counters provides statistics only for the selected
cells. For measurement task, at the most 10 cells can be selected. Each
selected cell can have up to 32 adjacent cells. These counters provide
handover statistics between the selected cells and their adjacent cells.
Table 40 lists all the measurement counters.

Before explanation of the counters it is necessary to understand the Intra-


MSC handover and Intra-BSC handover.

Intra-MSC Handover
1. Serving BSC takes the Handover decision based on the
measurement reports from the MS.
2. Serving BSC sends ‘Handover Required’ message to MSC if
handover is decided.
3. MSC sends ‘Handover Request’ message to the target BSC.
4. Target BSC sends ‘Handover Acknowledge’ to the MSC.
5. MSC sends ‘Handover Command’ to MS through the serving BSC.
6. Handovers between MS and the target BSC.
7. MS sends ‘Handover Complete’ message to the new BSC.

Confidential and Proprietary Information of ZTE CORPORATION 335


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

8. MSC sends ‘Channel Release’ command to the old BSC.


9. Old BSC replies ‘Channel Release Acknowledge’ message to MSC.

Intra-BSC Handover
1. Serving BSC takes the Handover decision based on the
measurement reports from the MS.
2. Serving BSC sends ‘Channel Activation’ message to target BTS if
handover is decided.
3. Target BTS replies ‘Channel Activation Acknowledge’ to the serving
BSC.
4. BSC sends ‘Handover Command’ message to the MS through
serving BTS.
5. Handovers between MS and the target BTS.
6. MS sends ‘Handover Complete’ message to the serving BSC on the
new channel.
7. New BTS sends ‘Channel Release’ command to the old BTS.
8. Old BTS replies ‘Channel Release Acknowledge’ message to new
BTS.

TABLE 40 ADJACENT CELL HANDOVER COUNTERS

Counter No. Counter Definition


C11101 Number of handover attempts on the adjacent cell.
C11102 Number of successful handovers from selected cell to the adjacent cell.
C11103 Number of handover attempts from adjacent cell to the selected cell.
C11104 Number of successful handovers from adjacent cell to the selected cell.
Number of handover attempts from selected cell to the adjacent cell
C11105
due to better uplink quality.
Number of handover attempts from selected cell to the adjacent cell
C11106
due to better downlink quality.
Number of successful handovers from selected cell to the adjacent cell
C11107
due to better uplink quality.
Number of successful handovers from selected cell to the adjacent cell
C11108
due to better downlink quality.
Number of handover attempts from selected cell to the adjacent cell
C11109
due to better uplink strength.
Number of handover attempts from selected cell to the adjacent cell
C11110
due to better downlink strength.
Number of successful handovers from selected cell to the adjacent cell
C11111
due to better uplink strength.

336 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 25 - Adjacent Cell Handover Measurement

Counter No. Counter Definition


Number of successful handovers from selected cell to the adjacent cell
C11112
due to better downlink strength.
Number of handover attempts from selected cell to the adjacent cell
C11113
due to PBGT
Number of successful handovers from selected cell to the adjacent cell
C11114
due to PBGT
Number of handover attempts from selected cell to the adjacent cell
C11115
due to other factors.

Adjacent Cell Handover Counters


Explanation
C11101
Definition

Number of handover attempts from selected cell to the adjacent cell.


Description
Counter ‘C11101’ represents the number of serving BSC attempts to
handover the MS from selected cell to the adjacent cell, whether its
Intra-MSC handover or intra-BSC handover.
Measurement Point

Counter increments in either of the following cases. Counter ‘C11101’


increments when:
Target BSC receives ‘Handover Required’ message from the serving
BSC through MSC, in case of Intra-MSC handover.
Target BTS receives ‘Channel Activation’ message from the serving
BSC, in case of Intra-BSC handover.

C11102
Definition

Number of successful handovers from selected cell to the adjacent cell


Description

Counter ‘C11102’ represents the number of BSC successfully


handovers the MS from selected cell to the adjacent cell.
Measurement Point

Counter ‘C11102’ increments in either of the following cases:

Confidential and Proprietary Information of ZTE CORPORATION 337


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Old BSC receives ‘Channel Release’ message from MSC, in case of


Intra-MSC handover.
New BTS receives ‘Handover Complete’ messages from MS, in case
of Intra-BSC handover.

C11103
Definition

Number of handover attempts from adjacent cell to the selected cell


Description

Counter ‘C11103’ represents the number of BSC attempts to handover


the MS from adjacent cell to the selected cell, whether its Intra-MSC
handover or intra-BSC handover.
Measurement Point

Counter ‘C11103’ increments in either of the following cases:


Target BSC receives ‘Handover Request’ message from MSC, in
case of Intra-MSC handover.
Target BTS receives ‘Channel Activation’ message from serving BSC,
in case of Intra-BSC handover.

C11104
Definition

Number of successful handovers from adjacent cell to the selected cell


Description

Counter ‘C11104’ represents the number of BSC successfully


handovers the MS from adjacent cell to the selected cell, whether its
Intra-MSC handover or Intra-BSC handover.
Measurement Point

Counter ‘C11104’ increments in either of the following cases. Target


BSC receives ‘Handover Complete’ message from MS through MSC, in
case of Intra-MSC handover.
New BTS receives ‘Handover Complete’ messages from MS, in case of
Intra-BSC handover.

C11105
Definition

Number of handover attempts from selected cell to the adjacent cell


due to better uplink quality
Description

338 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 25 - Adjacent Cell Handover Measurement

Counter ‘C11105’ represents the number of BSC attempts to handover


the MS from selected cell to the adjacent cell. Cause of handover is the
better uplink quality in the target cell. Counter represents for both
types of handovers, that is, Intra-MSC handover or intra-BSC handover.
Measurement Point
Counter ‘C11105’ increments in either of the following cases.
Target BSC receives ‘Handover Required’ message from the serving
BSC through MSC, in case of Intra-MSC handover.
Target BTS receives ‘Channel Activation’ message from serving BSC,
in case of Intra-BSC handover.

C11106
Definition

Number of handover attempts from selected cell to the adjacent cell


due to better downlink quality
Description

Counter ‘C11106’ represents the number of BSC attempts to handover


the MS from selected cell to the adjacent cell. Cause of handover
attempt is the better downlink quality in the adjacent cell. Counter
represents for both types of handovers, that is, Intra-MSC handover or
intra-BSC handover.
Measurement Point
Counter ‘C11106’ increments in either of the following cases. Target
BSC receives ‘Handover Required’ message from the serving BSC
through MSC, in case of Intra-MSC handover.
Target BTS receives ‘Channel Activation’ message from serving BSC,
in case of Intra-BSC handover.

C11107
Definition

Number of successful handovers from selected cell to the adjacent cell


due to better uplink quality
Description

Counter ‘C11107’ represents the number of BSC successfully


handovers the MS from selected cell to the adjacent cell. Cause of
handover is the better uplink quality in the adjacent cell. Counter
represents for both types of handovers, that is, Intra-MSC handover or
intra-BSC handover.
Measurement Point
Counter ‘C11107’ increments in either of the following cases.
Old BSC receives ‘Channel Release’ message from MSC, in case of
Intra-MSC handover.

Confidential and Proprietary Information of ZTE CORPORATION 339


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

New BTS receives ‘Handover Complete’ messages from MS, in case


of Intra-BSC handover.

C11108
Definition

Number of successful handovers from selected cell to the adjacent cell


due to better downlink quality
Description

Counter ‘C11108’ represents the number of BSC successfully


handovers the MS from selected cell to the adjacent cell. Cause of
handover is the better downlink quality in the adjacent cell. Counter
represents for both types of handovers, that is, Intra-MSC handover or
intra-BSC handover.
Measurement Point
Counter ‘C11108’ increments in either of the following cases.
Old BSC receives ‘Channel Release’ message from MSC, in case of
Intra-MSC handover.
New BTS receives ‘Handover Complete’ messages from MS, in case
of Intra-BSC handover.

C11109
Definition

Number of handover attempts from selected cell to the adjacent cell


due to better uplink strength.
Description

Counter ‘C11109’ represents the number of BSC attempts to handover


the MS from selected cell to the adjacent cell. Cause of handover
attempt is the better uplink strength in the adjacent cell. Counter
represents for both types of handovers, that is, Intra-MSC handover or
intra-BSC handover.
Measurement Point

Counter ‘C11109’ increments in either of the following cases. Counter


increments when:
Target BSC receives ‘Handover Required’ message from the serving
BSC through MSC, in case of Intra-MSC handover.
Target BTS receives ‘Channel Activation’ message from serving BSC,
in case of Intra-BSC handover.

C11110
Definition

340 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 25 - Adjacent Cell Handover Measurement

Number of handover attempts from selected cell to the adjacent cell


due to better downlink strength.
Description

Counter ‘C11110’ represents the number of BSC attempts to handover


the MS from selected cell to the adjacent cell. Cause of handover
attempt is the better downlink strength in the adjacent cell. Counter
represents for both types of handovers, that is, Intra-MSC handover or
intra-BSC handover.
Measurement Point

Counter ‘C11110’ increments in either of the following cases.


Target BSC receives ‘Handover Required’ message from the serving
BSC through MSC, in case of Intra-MSC handover.
Target BTS receives ‘Channel Activation’ message from serving BSC,
in case of Intra-BSC handover.

C11111
Definition

Number of successful handovers from selected cell to the adjacent cell


due to better uplink strength
Description

Counter ‘C11111’ represents the number of successful handovers from


selected cell to the adjacent cell. Cause for handover is the better
uplink strength in the adjacent cell. Counter represents for both types
of handovers, that is, Intra-MSC handover or intra-BSC handover.
Measurement Point
Counter ‘C11111’ increments in either of the following cases.
Old BSC receives ‘Channel Release’ message from MSC, in case of
Intra-MSC handover.
New BTS receives ‘Handover Complete’ messages from MS, in case
of Intra-BSC handover.

C11112
Definition

Number of successful handovers from selected cell to the adjacent cell


due to better downlink strength
Description

Counter ‘C1112’ represents the number of BSC successfully handovers


the MS from selected cell to the adjacent cell. Cause of handover is the
better downlink strength in the adjacent cell. Counter represents for
both types of handovers, that is, Intra-MSC handover or intra-BSC
handover.

Confidential and Proprietary Information of ZTE CORPORATION 341


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Measurement Point
Counter ‘C1112’ increments in either of the following cases.
Old BSC receives ‘Channel Release’ message from MSC, in case of
Intra-MSC handover.
New BTS receives ‘Handover Complete’ messages from MS, in case
of Intra-BSC handover.

C11113
Definition

Number of handover attempts from selected cell to the adjacent cell


due to PBGT
Description

Counter ‘C1113’ represents the number of BSC attempts to handover


the MS from selected cell to the adjacent cell. Cause of handover is
PBGT (Intra-MSC handover or intra-BSC handover).
Measurement Point

Counter ‘C1113’ increments in either of the following cases.


Target BSC receives ‘Handover Required’ message from the serving
BSC through MSC, in case of Intra-MSC handover.
Target BTS receives ‘Channel Activation’ message from serving BSC,
in case of Intra-BSC handover.

C11114
Definition

Number of successful handovers from selected cell to the adjacent cell


due to PBGT
Description

Counter ‘C1114’ represents the number of BSC successfully handovers


the MS from selected cell to the adjacent cell. Cause of handover is
PBGT (Intra-MSC handover or intra-BSC handover).
Measurement Point
Counter ‘C1114’ increments in either of the following cases:
Old BSC receives ‘Channel Release’ message from MSC, in case of
Intra-MSC handover.
New BTS receives ‘Handover Complete’ messages from MS, in case
of Intra-BSC handover.

C11115
Definition

342 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 25 - Adjacent Cell Handover Measurement

Number of handover attempts from selected cell to the adjacent cell


due to other factors.
Description

Counter ‘C1115’ represents the number of BSC attempts to handover


the MS from selected cell to the adjacent cell. Cause of handover is the
other factors such as traffic or rapid drop. Counter represents for both
types of handovers, that is, Intra-MSC handover or intra-BSC handover.
Measurement Point

Counter ‘C1115’ increments in either of the following cases.


Target BSC receives ‘Handover Required’ message from the serving
BSC through MSC, in case of Intra-MSC handover.
Target BTS receives ‘Channel Activation’ message from serving BSC,
in case of Intra-BSC handover.

C11116
Definition

Number of successful handovers from selected cell to the adjacent cell


due to other factors
Description

Counter ‘C1116’ represents the number of BSC successfully handovers


the MS from selected cell to the adjacent cell. Cause of handover is the
other factors such as traffic or rapid drop.
Measurement Point
Counter ‘C1116’ increments in either of the following cases.
Old BSC receives ‘Channel Release’ message from MSC, in case of
Intra-MSC handover.
New BTS receives ‘Handover Complete’ messages from MS, in case
of Intra-BSC handover.

Confidential and Proprietary Information of ZTE CORPORATION 343


This page is intentionally blank.

344 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 26

Phase-3 NMS Measurement


for Cell

This chapter introduces counters for phase-3 NMS – cell basic


measurement and measuring points.
Such basic measurement tasks are created as required in accordance with
phase three NMS. This task can be obtained from:
Basic measurement summary report
Some required statistics
Corresponding counter used for other measurement task

Phase-3 NMS Counters


This measurement task performs statistics on wireless indices involving
signal level, signal quality and power control. Measurement counters are
listed in Table 41.

TABLE 41 PHASE-3 NMS COUNTERS

Counter N0 Definition
C80001 Number of SDCCH RF call loss
C80002 Number of paging message sending failed
C80003 Mean number of seize PDCHs

C80004 Number of paging messages deleted from PCH queue


C80005 Number of normal increases of MS power due to uplink signal
level.
C80006 Number of rapid increase of mobile station power due to uplink
signal level.
C80007 Number of normal increases of MS power due to uplink signal
quality.
C80008 Number of rapid increase of mobile station power due to uplink
signal quality.

Confidential and Proprietary Information of ZTE CORPORATION 345


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Counter N0 Definition
C80009 Number of normal decrease of MS power due to up link signal
level.
C80010 Number of rapid decrease of MS power due to up link signal
level.
C80011 Number of normal decrease of MS power due to up link signal
quality.
C80012 Number of rapid decrease of MS power due to up link signal
quality.
C80013 Number of normal increases of BS power due to down link
signal level.
C80014 Number of rapid increases of BS power due to down link signal
level
C80015 Number of normal increases of BS power due to down link
signal quality.
C80016 Number of rapid increases of BS power due to down link signal
quality.
C80017 Number of normal decrease of BS power due to down link signal
level.
C80018 Number of rapid decrease of BS power due to down link signal
level.
C80019 Number of normal decrease of BS power due to down link signal
quality.
C80020 Number of normal decrease of BS power due to down link signal
quality.
C80021 Total value of each result of regular scanning of MS utilization
power
Number of regular scanning and sampling of MS utilization
C80022
power
Total value of each result of regular scanning of BS utilization
C80023
power
Number of regular scanning and sampling of BS utilization
C80024
power
C80025 Sum of uplink receiving strength of wireless channel
Sampling number of uplink receiving strength of wireless
C80026
channel
C80027 Sum of downlink receiving strength of wireless channel
Number of downlink receiving strength samples of wireless
C80028
channel
C80029 Sum of uplink quality levels of wireless channel
C80030 Number of uplink quality samples of wireless channel
C80031 Sum of downlink quality levels of wireless channel
C80032 Number of downlink quality samples of wireless channel
Number of handover out request failure due to unavailable
C80033
Intra-MSC wireless resource

346 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 26 - Phase-3 NMS Measurement for Cell

Counter N0 Definition
C80034 Number of failed SDCCH utilization due to carrier fault
C80035 Number of failed TCH utilization due to carrier fault
C80036 Total number of healthy TRXs
C80037 Number of outgoing dual-band handover execution
C80038 Number of successful outgoing dual-band handover
C80039 Number of incoming dual-band handover execution
C80040 Number of successful incoming dual-band handover
C11715 Number of call loss upon Intra-BSC internal handover failure

Phase-3 NMS Counters Explanation


C80001
Definition

Refer C10602 Counter Definition in section Call Drop Counters


Explanation
Calculation formula

C8001=C10602

C80002
Definition

Number of paging message sending failed

C80003
Definition

Mean number of seize PDCHs


Description
The number of PDCHs in database is sampled every 10 seconds.
The Mean number of seize PDCHs is sum of the sampling values
during a period of five minutes divided by sampling time. It reflects
Mean number of seize PDCHs in the cell.

C8004
Definition

Number of paging messages deleted from PCH queue

Confidential and Proprietary Information of ZTE CORPORATION 347


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C80005
Definition

Number of normal increases of MS power due to uplink signal level

Description

Total number of MS power normal increase of all the TRXs in cell due
to uplink signal level. Refer to C00001 Counter Definition in section
Power Control Counters Explanation.
Calculation Formula

C80005= Sum of C00001 counters of all the TRXs in the cell.

C80006
Definition

Number of rapid increase of mobile station power due to uplink


signal level

Description

Total number of times fast increase in MS power of all the TRXs in


the cell due to uplink signal level.

Calculation Formula

C80006=Sum of C00002 counters of all the TRXs in the cell.

C80007
Definition

Number of normal increases of mobile station power due to uplink


signal quality

Description

Total number of times normal increase in MS power of all the TRXs


in the cell due to uplink signal quality.

Calculation Formula

C80007=Sum of C00009 counters of all the TRXs in the cell.

C80008
Definition

Number of rapid increase of mobile station power due to uplink


signal quality

348 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 26 - Phase-3 NMS Measurement for Cell

Description

Total number of times rapid increase in MS power of all the TRXs in the
cell due to uplink signal quality.
Calculation Formula

C80008= Sum of C00010 counters of all the TRXs in the cell.

C80009
Definition

Number of normal decrease of mobile station power due to uplink


signal level

Description

Total number of times normal decrease in MS power of all the TRXs


in the cell due to uplink signal quality.

Calculation Formula

C80009=Sum of C0003 counters of all the TRXs in the cell.

C80010
Definition

Number of rapid increases of mobile station power due to uplink


signal level

Description

Total number of times rapid decrease in MS power of all the TRXs


in the cell due to uplink signal level.

Calculation formula

C80010=Sum of C0004 counters of all TRXs in the cell.

C80011
Definition

Number of normal decrease of mobile station power due to uplink


signal quality

Description

Total number of times normal decrease in MS power of all the TRXs


in the cell due to uplink signal quality.

Calculation formula

C80011= sum of C00011 counters of all the TRXs in the cell.

Confidential and Proprietary Information of ZTE CORPORATION 349


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C80012
Definition

Number of rapid decrease of mobile station power due to uplink


signal quality

Description

Total number of times fast decrease in MS power of all the TRXs in


the cell due to uplink signal quality.

Calculation formula

C80012= sum of C00012 counters of all the TRXs in the cell.

C80013
Definition

Number of normal increases of BS power due to down link signal


level

Description

Total number of times normal increase in BS power of all the TRXs


in the cell due to down link signal level.

Calculation formula

C80013= Sum of C00005 Counters of all the TRXs in the cell.

C80014
Definition

Number of rapid increase of BS power due to down link signal level

Description

Total number of times rapid increase in BS power of all the TRXs in


the cell due to down link signal level.

Calculation formula

C80014= Sum of C00006 Counters of all the TRXs in the cell.

C80015
Definition

Number of normal increases of BS power due to down link signal


quality

350 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 26 - Phase-3 NMS Measurement for Cell

Description

Total number of times normal increase of BS power of all the TRXs


in the cell due to down link signal quality.

Calculation formula

C80015= Sum of C00015 Counters of all the TRXs in the cell.

C80016
Definition

Number of rapid increase of BS power due to down link signal


quality

Description

Total number of times rapid increase in BS power of all the TRXs in


the cell due to down link signal quality.

Calculation formula

C80016= Sum of C00016 Counters of all the TRXs in the cell.

C80017
Definition

Number of normal decrease of BS power due to down link signal


level

Description

Total number of times normal decrease in BS power of all the TRXs


in the cell due to down link signal level.

Calculation formula

C80017= Sum of C00007 Counters of all the TRXs in the cell.

C80018
Definition

Number of rapid decrease of BS power due to down link signal level

Description

Total number of times rapid decrease in BS power of all the TRXs in


the cell due to down link signal level.

Calculation formula

C80018= Sum of C00008 Counters of all the TRXs in the cell.

Confidential and Proprietary Information of ZTE CORPORATION 351


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C80019
Definition

Number of normal decrease of BS power due to down link signal


quality

Description

Total number of times normal decrease in BS power of all the TRXs


in the cell due to down link signal quality.

Calculation formula

C80019= Sum of C00015 Counters of all the TRXs in the cell.

C80020
Definition

Number of rapid decrease of BS power due to down link signal


quality

Description

Total number of times rapid decrease of BS power of all the TRXs in


the cell due to down link signal quality.

Calculation formula

C80020= Sum of C00016 Counters of all the TRXs in the cell.

C80021
Definition

Total value of each result of MS utilization power regular scanning

Description

Total value of each result of ms utilization power regular scanning


on all the TRXs in a cell.

Calculation formula

C80021= Sum of C00017 Counters of all the TRXs in the cell.

C80022
Definition

Number of sampling number of MS utilization power regular


scanning

352 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 26 - Phase-3 NMS Measurement for Cell

Description

Number of sampling number of MS utilization power regular


scanning on all the TRXs in the cell.

Calculation formula

C80022= Sum of C00018 Counters of all the TRXs in the cell.

C80023
Definition

Total value of each result of BS utilization power regular scanning

Description

Total value of each result of BS utilization power regular scanning


on all the TRXs in the cell.

Calculation formula

C80023= Sum of C00019 Counters of all the TRXs in the cell.

C80024
Definition

Number of sampling number of BS utilization power regular scanning.


Description

Number of sampling number of BS utilization power regular scanning


on all the TRXs in the cell. Refer to C00020 in section Power Control
Counters Explanation.
Calculation formula

C80024= Sum of C00020 Counters of all the TRXs in the cell

C80025
Definition

Sum of uplink receiving strength of wireless channel

Calculation formula

C80025= C10710.

C80026
Definition

Number of uplink receiving strength samples

Confidential and Proprietary Information of ZTE CORPORATION 353


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Description

Refer to C10707 Counter Definition in section Channels Counters


Explanation.
Calculation formula

C80026= C10707.

C80027
Definition

Sum of down link receiving strength of wireless channel

Description

Refer to C10714 Counter Definition in section Channels Counters


Explanation.
Calculation formula

C80027= C10714.

C80028
Definition

Number of samples of downlink receiving strength

Description

Refer to C10711 Counter Definition in section Channels Counters


Explanation.
Calculation formula

C80028= C10711

C80029
Definition

Sum of the uplink quality level of wireless channel

Description

Refer to C10703 Counter Definition in section Channels Counters


Explanation.
Calculation formula

C80029= C10703

354 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 26 - Phase-3 NMS Measurement for Cell

C80030
Definition

Number of uplink quality samples of wireless channel


Description

Refer to the description of Counter C10701 in Section Channels


Counters Explanation.
Calculation formula
C80030 = C10701

C80031
Definition

Sum of downlink quality levels of wireless channel


Description

Refer to the description of Counter C10706 in Section Channels


Counters Explanation.
Calculation formula
C80031 = C10706

C80032
Definition

Number of downlink quality samples of wireless channel

Description

Refer to the description of Counter C10704 in Section Channels


Counters Explanation.
Calculation formula
C80032 = C10704

C80033
Definition

Number of handover out request failure due to unavailable Intra-MSC


wireless resource
Description

Refer to the description of Counter C10707 in Section Channels


Counters Explanation.
Calculation formula
C80033 = C10907

Confidential and Proprietary Information of ZTE CORPORATION 355


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C80034
Description

Number of failed SDCCH utilization due to carrier fault


Description

Number of carrier fault messages returned for SDCCH request from the
database
Calculation formula

Counting when carrier fault message is returned for SDCCH request


from the database

C80035
Definition

Number of failed TCH utilization due to carrier fault


Description

Number of carrier fault messages returned for TCH request from the
database, involving TCH/F and TCH/H
Calculation formula

Counting when carrier fault message is returned for TCH request from
the database

C80036
Definition

Total number of healthy TRXs


Description

Refer to the description of Counter C11520 in Resource Availability


Counters Explanation
Calculation formula

C80036 = C11520

C80037
Definition

Number of outgoing dual-band handover execution


Description

Refer to the description of Counter C109120 in Resource Availability


Counters Explanation.

356 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 26 - Phase-3 NMS Measurement for Cell

Calculation formula

C80037 = C109120

C80038
Definition

Number of successful outgoing dual-band handover


Description

Refer to the description of Counter C109121 in Section Handover


Counters Explanation.
Calculation formula
C80038 = C109121

C80039
Definition

Number of incoming dual-band handover execution

Description

Refer to the description of Counter C109123 in Section Handover


Counters Explanation.
Calculation formula
C80039 = C109123

C80040
Definition

Number of successful incoming dual-band handover


Description

Refer to the description of Counter C109124 in Section Handover


Counters Explanation.
Calculation formula
C80040 = C109124

C11715
Definition

Number of call loss upon Intra-BSC internal handover failure

Description

Call loss due to Intra-BSC intra-cell handover failure and inter-cell


handover failure.

Confidential and Proprietary Information of ZTE CORPORATION 357


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Measurement Point

C11715 increments when T3103 overflow message receives for Intra-


BSC inter-cell handover or the T3107 timer overflow message for
Intra-BSC intra-cell handover.

358 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 27

TCH/H Measurement

This chapter covers the following topics:

TCH/H Counters

TCH/H Counters
TCH/H measurement counters provide statistics for the:

TCH/H allocation requests


TCH/H allocations
TCH/H assignment requests
TCH/H assignments
TCH/H handover requests
TCH/H handovers
There are two types of Assignment flow:

Immediate Assignment
Common Assignment
Immediate Assignment: MS originates the assignment request, which BSC
has to fulfill.

Common Assignment: MSC originates the assignment command for the


MS.

Confidential and Proprietary Information of ZTE CORPORATION 359


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

FIGURE 32 and FIGURE 33 illustrates the two types of assignment flows.

FIGURE 32 - IMMIDIATE ASSIGNMENT FLOW

MS BTS BSC

CHL_REQ
CHL_RQD

A1

CHL_ACT

CHL_ACT_ACK

A2

IMM_ASS_CMD
IMM_ASS
SABM
EST_IND

A3

FIGURE 33 - COMMON ASSIGNMENT FLOW

MS BTS BSC MSC

ASS_CMD

B1
CHL_ACT
CHL_ACT_ACK

B2
ASS_CMD
ASS_CMD
SABM
UA EST_IND

B3
ASS_COM
ASS_COM

B4
ASS_COM

There are two types of handover flows:

Internal Handover
External Handover
FIGURE 34and FIGURE 35 illustrates the two types of assignment flows.

360 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 27 - TCH/H Measurement

Internal Handover: Handover without the involvement of MSC.

External Handover: Handover with the involvement of MSC.

FIGURE 34 - INTERNAL HANDOVER (INTRA-BSC HANDOVER)

MS BTS BSC MSC

MEAS_REP
MEAS_RES

C1
CHL_ACT
CHL_ACT_ACK

C2
ASS_CMD
ASS_CMD
SABM
UA EST_IND
ASS_COM
ASS_COM

C3
HO_PREFORM

FIGURE 35 - EXTERNAL HANDOVER (INTRA-MSC HANDOVER)

MS BTS BSC MSC

HO_REQ

D1
CHL_ACT
CHL_ACT_ACK

D2
HO_REQ_ACK
HO_ACCESS
HO_DETECT
PHY_INFO
HO_DETECT
SABM
UA
HO_COM
HO_COM

D3
HO_COM

Table 42 lists all the TCH/H measurement counters.

Confidential and Proprietary Information of ZTE CORPORATION 361


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

TABLE 42 TCH/H MEASUREMENT COUNTERS

Counter No. Definition


C10401 Number of requests for TCH/H assignment (signaling)
C10402 Number of successful TCH/H assignment request (signaling)
C10403 Number of unsuccessful TCH/H assignment request (signaling)
C10404 Number of requests for TCH/H handover (signaling)
C10405 Number of successful TCH/H handover request(signaling)
C10406 Number of unsuccessful TCH/H handover request(signaling)
C10407 Number of BSC attempts to allocate TCH/H for assignment (signaling)
C10408 Number of successful TCH/H allocation for assignment (signaling)
C10409 Number of unsuccessful TCH/H allocation for assignment (signaling)
C10410 Number of BSC attempts to allocate TCH/H in case of handover (signaling)
C10411 Number of successful TCH/H allocation in case of handover (signaling)
C10412 Number of unsuccessful TCH/H allocation in case of handover (signaling)
C10413 Number of BSC attempts to assign TCH/H (signaling)
C10414 Number of successful TCH/H assignment (signaling)
C10415 Number of unsuccessful TCH/H assignment (signaling)
C10416 Number of handover attempts for TCH/H (signaling).
C10417 Number of successful TCH/H handover (Signaling)
C10418 Number of unsuccessful TCH/H handover (Signaling)
Number of BSC does not receives ‘Handover Fail’ message on the TCH/H
C10419
(signaling)
C10420 Number of requests for TCH/H assignment (voice)
C10421 Number of successful TCH/H assignment request (voice)
C10422 Number of unsuccessful TCH/H assignment request (voice)
C10423 Number of requests for TCH/H handover (voice)
C10424 Number of successful TCH/H handover request(voice)
C10425 Number of unsuccessful TCH/H handover request(voice)
Number of BSC attempts to allocate TCH/H for assignment (voice version
C10426
1)
C10427 Number of successful TCH/H allocation for assignment (voice version 1)
C10428 Number of unsuccessful TCH/H allocation for assignment (voice version 1)
Number of BSC attempts to allocate TCH/H during handover (voice version
C10429
1)
C10430 Number of successful TCH/H allocation during handover (voice version 1)
Number of unsuccessful TCH/H allocation during handover (voice version
C10431
1)

362 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 27 - TCH/H Measurement

Number of BSC attempts to allocate TCH/H for assignment (voice version


C10432
2)
C10433 Number of successful TCH/H allocation for assignment (voice version 2)
C10434 Number of unsuccessful TCH/H allocation for assignment (voice version 2)
C10435 Number of BSC attempts to allocate TCH/H for handover (voice version 2)
C10436 Number of successful TCH/H allocation for handover (voice version 2)
C10437 Number of unsuccessful TCH/H allocation for handover (voice version 2)
Number of BSC attempts to allocate TCH/H for assignment (voice version
C10438
3)
C10439 Number of successful TCH/H allocation for assignment (voice version 3)
C10440 Number of unsuccessful TCH/H allocation for assignment (voice version 3)
C10441 Number of BSC attempts to allocate TCH/H for handover (voice version 3)
C10442 Number of successful TCH/H allocation for handover (voice version 3)
C10443 Number of unsuccessful TCH/H allocation for handover (voice version 3)
C10444 Number of BSC attempts to assign TCH/H (Voice)
C10445 Number of successful TCH/H assignment (Voice)
C10446 Number of unsuccessful TCH/H assignment (Voice)
C10447 Number of handover attempts for TCH/H (Voice).
C10448 Number of successful TCH/H handover (Voice)
C10449 Number of unsuccessful TCH/H handover (Voice)
Number of BSC does not receives ‘Handover Fail’ message on the TCH/H
C10450
(Voice)
C10451 Number of requests for TCH/H assignment (data)
C10452 Number of successful TCH/H assignment request (data)
C10453 Number of unsuccessful TCH/H assignment request (data)
C10454 Number of requests for TCH/H handover (data)
C10455 Number of successful request for TCH/H handover (data)
C10456 Number of unsuccessful request for TCH/H handover (data)
C10457 Number of BSC attempts to allocate TCH/H for assignment (data)
C10458 Number of successful TCH/H allocation for assignment (data)
C10459 Number of unsuccessful TCH/H allocation for assignment (data)
C10460 Number of BSC attempts to allocate TCH/H for handover (data)
C10461 Number of successful TCH/H allocation for handover (data)
C10462 Number of unsuccessful TCH/H allocation for handover (data)
C10463 Number of BSC attempts to assign TCH/H (data)
C10464 Number of successful TCH/H assignment (data)
C10465 Number of unsuccessful TCH/H assignment (data)
C10466 Number of handover attempts for TCH/H (data).
C10467 Number of successful TCH/H handover (data)

Confidential and Proprietary Information of ZTE CORPORATION 363


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C10468 Number of unsuccessful TCH/H handover (data)


Number of BSC does not receives ‘Handover Fail’ message on the TCH/H
C10469
(data)

TCHH Counters Explanation


C10401
Definition

Number of requests for TCH/H assignment (signaling)


Description
Number of requests for TCH/H assignment = Number of successful
request for TCH/H assignment (signaling) + Number of unsuccessful
request for TCH/H assignment (signaling)

Calculation Formula

C10401 = C10402 + C10403


Measurement Point
Counter ‘C10401’ increments at the same time with counters ‘C10402’
or ‘C10403’.

C10402
Definition

Number of successful request for TCH/H assignment (signaling)


Description
Request for TCH/H assignment is successful when BSC allocates the
TCH/H. This counter keeps the represents of number of successful
requests for TCH/H assignment as a signaling channel.
Measurement Point

Counter ‘C10402’ increments when BSC successfully allocates the


TCH/H.

C10403
Definition

Number of unsuccessful request for TCH/H assignment (signaling)


Description

Request for TCH/H assignment is unsuccessful if BSC receives negative


acknowledgement in reply of channel activation request. This counter

364 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 27 - TCH/H Measurement

keeps represents of number of unsuccessful requests for TCH/H


assignment as a signaling channel.
Measurement Point

Counter ‘C10403’ increments when BSC receives the negative


acknowledgment in response to the ‘Channel Activation’ message.

C10404
Definition

Number of requests for TCH/H handover (signaling)


Description

Number of requests for TCH/H handover (signaling) = Number of


successful request for TCH/H handover (signaling) + Number of
unsuccessful request for TCH/H handover (signaling)
Calculation Formula

C10404 = C10405 + C10406


Measurement Point
Counter ‘C10404’ has the measurement point same like counter
‘C10405’ or counter ‘C10406’.

C10405
Definition

Number of successful request for TCH/H handover (signaling)


Description

Request for TCH/H handover is successful when BSC allocates the


TCH/H. This counter keeps the represents of number of successful
requests for TCH/H handover as a signaling channel.
Measurement Point

Counter ‘C10405’ increments when BSC successfully allocates the


TCH/H.

C10406
Definition

Number of unsuccessful request for TCH/H handover (signaling)


Description
Request for TCH/H handover is unsuccessful if BSC receives negative
acknowledgement in reply of channel activation request. This counter
keeps the represents of number of unsuccessful requests for TCH/H
handover as a signaling channel.
Measurement Point

Confidential and Proprietary Information of ZTE CORPORATION 365


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Counter ‘C10406’ increments when BSC receives negative


acknowledgment in response to the ‘Channel Activation’ message.

C10407
Definition

Number of BSC attempts to allocate TCH/H for assignment (signaling)


Description
Counter ‘C10407’ represents the number of BSC attempts to activate
TCH/H to assign it to the MS, for the signaling purpose.
Calculation Formula
Number of BSC attempts to allocate TCH/H for assignment (signaling)
= Number of successful TCH/H allocation for assignment (signaling) +
Number of unsuccessful TCH/H allocation for assignment (signaling)
(C10407)= C10408 + C10409
Measurement Point
Counter ‘C10407’ increments at the same time with counters ‘C10408’
or ‘C10409’.

C10408
Definition

Number of successful TCH/H allocation for assignment (signaling)


Description
Counter ‘C10408’ represents the number of BSC successfully activates
the TCH/H, in order to assign it to the MS as a signaling channel.
Measurement Point

Counter ‘C10408’ increments when BSC receives ‘Channel Activation


Acknowledgement’ message from BTS, in case of successful allocation
of the TCH/H (A2-FIGURE 32).

C10409
Definition

Number of unsuccessful TCH/H allocation for assignment (signaling)


Description
Counter ‘C10409’ represents the number of BSC fails to activate the
TCH/H, in order to assign it to the MS as a signaling channel. Causes
for the failure can be:
Timeout for timer T9103
Overload
Function (channel) not available
Measurement Point

366 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 27 - TCH/H Measurement

Counter ‘C10409’ increments when BSC receives negative


acknowledgment in response to the ‘Channel Activation’ message.

C10410
Definition

Number of BSC attempts to allocate TCH/H in case of handover


(signaling)
Description
Counter ‘C10410’ represents the number of BSC attempts to activate
TCH/H as a signaling channel in case of handover.
Calculation Formula

Number of BSC attempts to allocate TCH/H in case of handover


(signaling) = Number of successful TCH/H allocation in case of
handover (signaling) + Number of unsuccessful TCH/H allocation in
case of handover (signaling)
C10410 = C10411 + C10412
Measurement Point
Counter ‘C10410’ increments at the same time with counters ‘C10411’
or ‘C10412’.

C10411
Definition

Number of successful TCH/H allocation in case of handover (signaling)


Description
Counter ‘C10411’ represents the number of BSC successfully activates
the TCH/H as a signaling channel during the handover.
Measurement Point

Counter ‘C10411’ increments when BSC receives ‘Channel Activation


Acknowledgment’ message from BTS (C2-FIGURE 34 and D2-FIGURE
35).

C10412
Definition

Number of unsuccessful TCH/H allocation in case of handover


(signaling)
Description
Counter ‘C10412’ represents the number of BSC fails to activate the
TCH/H as a signaling channel during the handover.
Measurement Point

Confidential and Proprietary Information of ZTE CORPORATION 367


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Counter ‘C10412’ increments when BSC receives negative


acknowledgment in response to the ‘Channel Activation’ message.

C10413
Definition

Number of BSC attempts to assign TCH/H (signaling)


Description
Counter ‘C10413’ represents the number of BSC attempts to assign
TCH/H to the MS as a signaling channel.
Calculation Formula

Number of BSC attempts to assign TCH/H (signaling) = Number of


successful TCH/H assignment (signaling) + Number of unsuccessful
TCH/H assignment (signaling)
C10413 = C10414 + C10415
Measurement Point
Counter ‘C10413’ increments at the same time with counters ‘C10414’
or ‘C10415’.

C10414
Definition

Number of successful TCH/H assignment (signaling)


Description
Counter ‘C10414’ represents the number of BSC successfully assigns
the TCH/H as a signaling channel.
Measurement Point

Counter ‘C10414’ increments when BSC receives ‘Establish indication’


message from BTS (A3-FIGURE 32).

C10415
Definition

Number of unsuccessful TCH/H assignment (signaling)


Description
Counter ‘C10415’ represents the number of BSC fails to assign TCH/H
to MS as a signaling channel.
Measurement Point
Counter ‘C10415’ increments when BSC receives negative
acknowledgment in response to the ‘Assignment Command’ message.

C10416
Definition

368 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 27 - TCH/H Measurement

Number of handover attempts for TCH/H (signaling)


Description
Counter ‘C10416’ represents the number of BSC attempts to handover
the MS on new TCH/H as a signaling channel. Handover involves both
intra-cell and inter-cell handover.
Calculation Formula

Number of handover attempts for TCH/H (signaling) = Number of


successful TCH/H handover (Signaling) + Number of successful TCH/H
handover (Signaling)
C10416 = C10417 + C10418
Measurement Point

Counter ‘C10416’ has the measurement point same like counter


‘C10417’ or counter ‘C10418’.

C10417
Definition

Number of successful TCH/H handover (Signaling)


Description

Counter ‘C10417’ represents the number of BSC receives signaling of


handover success on the new TCH/H. This counter represents for inter-
cell and intra-cell handover.
Measurement Point
Counter ‘C10417” increments when BSC receives ‘Assignment
Complete’ (intra-cell handover) or ‘Handover Complete’ message
(inter-cell handover) on the new TCH/H. Refer to FIGURE 34-C3 and
FIGURE 35-D3.

C10418
Definition

Number of unsuccessful TCH/H handover (Signaling)


Description

Counter ‘C10418’ represents the number of BSC does not receive


handover success information on the new TCH/H. This counter
represents for inter-cell and intra-cell handover.

Measurement Point
Counter ‘C10418” increments when BSC receives ‘Handover Fail’
message (inter-cell handover) on old TCH/H.

Confidential and Proprietary Information of ZTE CORPORATION 369


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C10419
Definition

Number of BSC does not receive ‘Handover Fail’ message on the TCH/H
(signaling)
Description

Not Implemented
Measurement Point
Not Implemented

C10420
Definition

Number of requests for TCH/H assignment (voice)


Description
Number of requests for TCH/H assignment (voice) = Number of
successful request for TCH/H assignment (voice) + Number of
unsuccessful request for TCH/H assignment (voice)
Calculation Formula

C10420 = C10421 + C10422


Measurement Point
Counter ‘C10420’ increments at the same time with counters ‘C10421’
or ‘C10422’.

C10421
Definition

Number of successful request for TCH/H assignment (voice)


Description
Success of TCH/H assignment request depends upon successful TCH/H
allocation. This counter keeps the represents of number of successful
requests for TCH/H assignment as a voice channel.
Measurement Point

Counter ‘C10402’ increments when BSC successfully allocates the


TCH/H.

C10422
Definition

Number of unsuccessful TCH/H assignment (voice)

370 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 27 - TCH/H Measurement

Description

Request for TCH/H assignment fails if BSC receives negative


acknowledgement in reply of channel activation request. This counter
keeps the represents of number of unsuccessful requests for TCH/H
assignment as a voice channel.
Measurement Point

Counter ‘C10403’ increments when BSC receives the negative


acknowledgment in response of the ‘Channel Activation’ message.

C10423
Definition

Number of requests for TCH/H handover (voice)


Description
Number of requests for TCH/H handover (voice) = Number of
successful request for TCH/H handover (voice) + Number of
unsuccessful request for TCH/H handover (voice)
Calculation Formula

C10423 = C10424 + C10425


Measurement Point
Counter ‘C10423’ increments at the same time with counters ‘C10424’
or ‘C10425’.

C10424
Definition

Number of successful request for TCH/H handover (voice)


Description
Request for TCH/H handover only succeeds when BSC successfully
allocates the TCH/H. This counter keeps represents of number of
requests for TCH/H handover as a voice channel.
Measurement Point

Counter ‘C10424’ increments when BSC successfully allocates the


TCH/H.

C10425
Definition

Number of unsuccessful request for TCH/H handover (voice)


Description

Request for TCH/H handover fails when BSC receives negative


acknowledgement for the channel activation request. This counter

Confidential and Proprietary Information of ZTE CORPORATION 371


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

keeps the represents of number of unsuccessful requests for TCH/H


handover as a voice channel.
Measurement Point

Counter ‘C10425’ increments when BSC receives the negative


acknowledgment in response to the ‘Channel Activation’ message.

C10426
Definition

Number of BSC attempts to allocate TCH/H for assignment (voice


version 1)
Description
Counter ‘C10410’ represents the number of BSC attempts to activate
TCH/H as a voice channel (version 1) for the assignment purpose.
Calculation Formula

Number of BSC attempts to allocate TCH/H for assignment (voice


version 1) = Number of successful TCH/H allocation for assignment
(voice version 1) + Number of unsuccessful TCH/H allocation for
assignment (voice version 1)
C10426 = C10427 + C10428
Measurement Point
Counter ‘C10426’ increments at the same time with counters ‘C10427’
or ‘C10428’.

C10427
Definition

Number of successful TCH/H allocation for assignment (voice version 1)


Description
Counter ‘C10427’ represents the number of BSC successfully activates
the TCH/H as a voice channel (version 1) for the assignment purpose.
Measurement Point

Counter ‘C10427’ increments when BSC receives ‘Channel Activation


Acknowledgment’ message from BTS (A2-FIGURE 32 and B2-FIGURE
33).

C10428
Definition

Number of unsuccessful TCH/H allocation for assignment (voice


version1)

372 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 27 - TCH/H Measurement

Description
Counter ‘C10412’ represents the number of BSC fails to activate the
TCH/H as a voice channel (version 1) for the assignment purpose.
Causes for the failure can be:
Timeout for timer T9103
Overload
Function (channel) not available
Measurement Point

Counter ‘C10428’ increments when BSC receives negative


acknowledgment in response to the ‘Channel Activation’ message.

C10429
Definition

Number of BSC attempts to allocate TCH/H for handover (voice version


1)
Description
Counter ‘C10429’ represents the number of BSC attempts to activate
TCH/H as a voice channel (version 1) for the handover purpose.
Calculation Formula

Number of BSC attempts to allocate TCH/H for handover (voice version


1) = Number of successful TCH/H allocation for handover (voice
version 1) + Number of unsuccessful TCH/H allocation for handover
(voice version 1)
C10429 = C10430 + C10431
Measurement Point
Counter ‘C10429’ increments at the same time with counters ‘C10430’
or ‘C10431’.

C10430
Definition

Number of successful TCH/H allocation for handover (voice version 1)


Description
Counter ‘C10430’ represents the number of BSC successfully activates
the TCH/H as a voice channel (version 1) in case of handover.
Measurement Point

Counter ‘C10430’ increments when BSC receives ‘Channel Activation


Acknowledgment’ message from BTS (C2-FIGURE 34 and D2-FIGURE
35).

Confidential and Proprietary Information of ZTE CORPORATION 373


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C10431
Definition

Number of unsuccessful TCH/H allocation for handover (voice version1)


Description
Counter ‘C10431’ represents the number of BSC fails to activate TCH/H
as a voice channel (version 1) for the handover purpose. Causes for
the failure can be:
Timeout for timer T9103
Overload
Function (channel) not available
Measurement Point

Counter ‘C10431’ increments when BSC receives negative


acknowledgment in response to the ‘Channel Activation’ message.

C10432
Definition

Number of BSC attempts to allocate TCH/H for assignment (voice


version 2)
Description
Counter ‘C10432’ represents the number of BSC attempts to activate
TCH/H as a voice channel (version 2) for the assignment purpose.
Calculation Formula

Number of BSC attempts to allocate TCH/H for assignment (voice


version 2) = Number of successful TCH/H allocation assignment (voice
version 2) + Number of unsuccessful TCH/H allocation assignment
(voice version 2)
C10432 = C10433 + C10434
Measurement Point
Counter ‘C10432’ increments at the same time with counters ‘C10433’
or ‘C10434’.

C10433
Definition

Number of successful TCH/H allocation assignment (voice version 2)


Description
Counter ‘C10433’ represents the number of BSC successfully activates
the TCH/H as a voice channel (version 2) for the assignment purpose.

374 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 27 - TCH/H Measurement

Measurement Point

Counter ‘C10433’ increments when BSC receives ‘Channel Activation


Acknowledgment’ message from BTS (A2-FIGURE 32 and B2-FIGURE
33).

C10434
Definition

Number of unsuccessful TCH/H allocation assignment (voice version 2)


Description
Counter ‘C10434’ represents the number of BSC fails to activate the
TCH/H as a voice channel (version 2) for the assignment purpose.
Causes for the failure can be:
Timeout for timer T9103
Overload
Function (channel) not available
Measurement Point

Counter ‘C10434’ increments when BSC receives negative


acknowledgment in response to the ‘Channel Activation’ message.

C10435
Definition

Number of BSC attempts to allocate TCH/H for handover (voice version


2)
Description
Counter ‘C10435’ represents the number of BSC attempts to activate
TCH/H as a voice channel (version 2) for the handover purpose.
Calculation Formula

Number of BSC attempts to allocate TCH/H for handover (voice version


2) = Number of successful TCH/H allocation for handover (voice
version 2) + Number of unsuccessful TCH/H allocation for handover
(voice version 2)
C10435 = C10436 + C10437
Measurement Point
Counter ‘C10435’ increments at the same time with counters ‘C10436’
or ‘C10437’.

C10436
Definition

Number of successful TCH/H allocation for handover (voice version 2)

Confidential and Proprietary Information of ZTE CORPORATION 375


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Description
Counter ‘C10430’ represents the number of BSC successfully activates
the TCH/H as a voice channel (version 1) in case of handover.
Measurement Point

Counter ‘C10436’ increments when BSC receives ‘Channel Activation


Acknowledgment’ message from BTS (C2-FIGURE 34 and D2-FIGURE
35).

C10437
Definition

Number of unsuccessful TCH/H allocation for handover (voice version 2)


Description
Counter ‘C10437’ represents the number of BSC fails to activate the
TCH/H as a voice channel (version 2) for the handover purpose.
Causes for the failure can be:
Timeout for timer T9103
Overload
Function (channel) not available
Measurement Point

Counter ‘C10437’ increments when BSC receives negative


acknowledgment in response to the ‘Channel Activation’ message.

C10438
Definition

Number of BSC attempts to allocate TCH/H for assignment (voice


version 3)
Description
Counter ‘C10439’ represents the number of BSC attempts to activate
TCH/H as a voice channel (version 3) for the assignment purpose.
Calculation Formula

Number of BSC attempts to allocate TCH/H for assignment (voice


version 3) = Number of successful TCH/H allocation for assignment
(voice version 3) + Number of unsuccessful TCH/H allocation for
assignment (voice version 3)
C10438 = C10439 + C10440
Measurement Point
Counter ‘C10438’ increments at the same time with counters ‘C10439’
or ‘C10440’.

376 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 27 - TCH/H Measurement

C10439
Definition

Number of successful TCH/H allocation for assignment (voice version 3)


Description
Counter ‘C10439’ represents the number of BSC successfully activates
the TCH/H as a voice channel (version 2) for the assignment purpose.
Measurement Point

Counter ‘C10439’ increments when BSC receives ‘Channel Activation


Acknowledgment’ message from BTS (A2-FIGURE 32 and B2-FIGURE
33).

C10440
Definition
Number of unsuccessful TCH/H allocation for assignment (voice
version 3)
Description
Counter ‘C10440’ represents the number of BSC fails to activate the
TCH/H as a voice channel (version 2) for the assignment purpose.
Causes for the failure can be:
Timeout for timer T9103
Overload
Function (channel) not available
Measurement Point

Counter ‘C10440’ increments when BSC receives negative


acknowledgment in response to the ‘Channel Activation’ message.

C10441
Definition

Number of BSC attempts to allocate TCH/H for handover (voice version


3)
Description
Counter ‘C10441’ represents the number of BSC attempts to activate
TCH/H as a voice channel (version 3) for the handover purpose.
Calculation Formula

Number of BSC attempts to allocate TCH/H for handover (voice version


3) = Number of successful TCH/H allocation for handover (voice
version 3) + Number of unsuccessful TCH/H allocation for handover
(voice version 3)
C10441 = C10442 + C10443

Confidential and Proprietary Information of ZTE CORPORATION 377


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Measurement Point
Counter ‘C10441’ increments at the same time with counters ‘C10442’
or ‘C10443’.

C10442
Definition

Number of successful TCH/H allocation for handover (voice version 3)


Description
Counter ‘C10442’ represents the number of BSC successfully activates
the TCH/H as a voice channel (version 3) in case of handover.
Measurement Point

Counter ‘C10442’ increments when BSC receives ‘Channel Activation


Acknowledgment’ message from BTS (C2-FIGURE 34 and D2-FIGURE
35).

C10443
Definition

Number of unsuccessful TCH/H allocation for handover (voice version 3)


Description
Counter ‘C10443’ represents the number of BSC fails to activate the
TCH/H as a voice channel (version 3) for the handover purpose.
Causes for the failure can be:
Timeout for timer T9103
Overload
Function (channel) not available
Measurement Point

Counter ‘C10443’ increments when BSC receives negative


acknowledgment in response to the ‘Channel Activation’ message.

C10444
Definition

Number of BSC attempts to assign TCH/H (Voice)


Description
Counter ‘C10444’ represents the number of BSC attempts to assign
TCH/H to the MS in order to carry the user speech.
Calculation Formula

Number of BSC attempts to assign TCH/H (Voice) = Number of


successful TCH/H assignment (Voice) + Number of successful TCH/H
assignment (Voice)

378 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 27 - TCH/H Measurement

C10444 = C10445 + C10446


Measurement Point
Counter ‘C10444’ increments at the same time with counters ‘C10445’
or ‘C10446’.

C10445
Definition

Number of successful TCH/H assignment (Voice)


Description
Counter ‘C10445’ represents the number of BSC successfully assigns
TCH/H to the MS in order to carry the user speech.
Measurement Point

Counter ‘C10445’ increments when BSC receives ‘Establish indication’


message from BTS (A3-FIGURE 32).

C10446
Definition

Number of unsuccessful TCH/H assignment (Voice)


Description
Counter ‘C10446’ represents the number of BSC fails to assign TCH/H
to the MS in order to carry the user speech.
Measurement Point
Counter ‘C10446’ increments when BSC receives negative
acknowledgment in response to the ‘Assignment Command’ message.

C10447
Definition

Number of handover attempts for TCH/H (Voice).


Description
Counter ‘C10447’ represents the number of BSC attempts to handover
the MS on new TCH/H voice channel, in case of both intra-cell and
inter-cell handover.
Calculation Formula

Number of handover attempts for TCH/H (Voice) = Number of


successful TCH/H handover (Voice) + Number of successful TCH/H
handover (Voice)
C10447 = C10448 + C10449

Confidential and Proprietary Information of ZTE CORPORATION 379


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Measurement Point

Counter ‘C10447’ has the measurement point same like counter


‘C10448’ or counter ‘C10449’.

C10448
Definition

Number of successful TCH/H handover (Voice)


Description

Counter ‘C10448’ represents the number of BSC receives signaling


about handover success on the new TCH/H voice channel. Handover
includes both inter-cell and intra-cell handover.
Measurement Point
Counter ‘C10448” increments when BSC receives ‘Assignment
Complete’ (intra-cell handover) or ‘Handover Complete’ message
(inter-cell handover) on the new TCH/H (Voice). Refer to FIGURE 34-
C3 and FIGURE 35-D3.

C10449
Definition
Number of unsuccessful TCH/H handover (Voice)
Description

Counter ‘C10449’ represents the number of BSC fails to receive


signaling about handover success on the new TCH/H voice channel.
Handover includes both inter-cell and intra-cell handover.
Measurement Point
Counter ‘C10449” increments when BSC receives ‘Handover Fail’
message (inter-cell handover) on old TCH/H.

C10449
Definition

Number of BSC receives ‘Handover Fail’ message on the TCH/H (Voice)


Description

Not Implemented
Measurement Point
Not Implemented

380 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 27 - TCH/H Measurement

C10450
Definition

Number of BSC does not receives ‘Handover Fail’ message on the


TCH/H (Voice)
Description

Not Implemented
Measurement Point
Not Implemented

C10451
Definition

Number of requests for TCH/H assignment (data)


Description
Number of requests for TCH/H assignment (data) = Number of
successful request for TCH/H assignment (data) + Number of
successful request for TCH/H assignment (data)
Calculation Formula
C10451 = C10452 + C10453
Measurement Point
Counter ‘C10451’ increments at the same time with counters ‘C10452’
or ‘C10453’.

C10452
Definition

Number of successful request for TCH/H assignment (data)


Description
Request for TCH/H assignment only succeeds when BSC successfully
allocates the TCH/H. This counter keeps represents of number of
requests for TCH/H assignment as a data channel.
Measurement Point

Counter ‘C10452’ increments when BSC successfully allocates the


TCH/H.

C10453
Definition

Number of unsuccessful request for TCH/H assignment (data)

Confidential and Proprietary Information of ZTE CORPORATION 381


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Description

Request for TCH/H assignment only fails when BSC receives negative
acknowledgement for the channel activation request. This counter is
only to keep record of number of unsuccessful requests for TCH/H
assignment as a data channel.
Measurement Point

Counter ‘C10453’ increments when BSC receives the negative


acknowledgment in response to the ‘Channel Activation’ message.

C10454
Definition

Number of requests for TCH/H handover (data)


Description
Number of requests for TCH/H handover (data) = Number of
successful TCH/H request for handover (data) + Number of successful
TCH/H request for handover (data)
Calculation Formula

C10454 = C10455 + C10456


Measurement Point
Counter ‘C10454’ increments at the same time with counters ‘C10455’
or ‘C10456’.

C10455
Definition

Number of successful TCH/H request for handover (data)


Description
Request for TCH/H handover only succeeds when BSC successfully
allocates the TCH/H. This counter keeps the represents of number of
requests for TCH/H handover as a data channel.
Measurement Point

Counter ‘C10455’ increments when BSC successfully allocates the


TCH/H.

C10456
Definition

Number of unsuccessful TCH/H request for handover (data)


Description

Request for TCH/H assignment only fails when BSC receives negative
acknowledgement for the channel activation request. This counter is

382 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 27 - TCH/H Measurement

only to keep record of number of unsuccessful requests for TCH/H


handover as a data channel.
Measurement Point

Counter ‘C10456’ increments when BSC receives the negative


acknowledgment in response to the ‘Channel Activation’ message.

C10457
Definition

Number of BSC attempts to allocate TCH/H for assignment (data)


Description
Counter ‘C10457’ represents the number of BSC attempts to activate
TCH/H as a data channel for the assignment purpose.
Calculation Formula

Number of BSC attempts to allocate TCH/H for assignment (data) =


Number of successful TCH/H allocation for assignment (data) +
Number of unsuccessful TCH/H allocation for assignment (data)
C10457 = C10458 + C10459
Measurement Point
Counter ‘C10457’ increments at the same time with counters ‘C10458’
or ‘C10459’.

C10458
Definition

Number of successful TCH/H allocation for assignment (data)


Description
Counter ‘C10458’ represents the number of BSC successfully activates
the TCH/H as a voice channel (data) for the assignment purpose.
Measurement Point

Counter ‘C10458’ increments when BSC receives ‘Channel Activation


Acknowledgment’ message from BTS (A2-FIGURE 32 and B2-FIGURE
33).

C10459
Definition

Number of unsuccessful TCH/H allocation for assignment (data)


Description
Counter ‘C10459’ represents the number of BSC fails to activate the
TCH/H as a data channel for the assignment purpose. Causes for the
failure can be:

Confidential and Proprietary Information of ZTE CORPORATION 383


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Timeout for timer T9103


Overload
Function (channel) not available
Measurement Point

Counter ‘C10459’ increments when BSC receives negative


acknowledgment in response to the ‘Channel Activation’ message.

C10460
Definition

Number of BSC attempts to allocate TCH/H for handover (data)


Description
Counter ‘C10460’ represents the number of BSC attempts to activate
TCH/H as a data channel for the handover purpose.
Calculation Formula

Number of BSC attempts to allocate TCH/H for handover (data) =


Number of successful TCH/H allocation for handover (data) + Number
of unsuccessful TCH/H allocation for handover (data)
C10460 = C10461 + C10462
Measurement Point
Counter ‘C10460’ increments at the same time with counters
‘C10461’or ‘C10462’.

C10461
Definition

Number of successful TCH/H allocation for handover (data)


Description
Counter ‘C10461’ represents the number of BSC successfully activates
the TCH/H as a data channel in case of handover.
Measurement Point

Counter ‘C10461’ increments when BSC receives ‘Channel Activation


Acknowledgment’ message from BTS (C2-FIGURE 34 and D2-FIGURE
35).

C10462
Definition

Number of unsuccessful TCH/H allocation for handover (data)


Description

384 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 27 - TCH/H Measurement

Counter ‘C10462’ represents the number of BSC fails to activate the


TCH/H as a data channel for the handover purpose. Causes for the
failure can be:
Timeout for timer T9103
Overload
Function (channel) not available
Measurement Point

Counter ‘C10462’ increments when BSC receives negative


acknowledgment in response to the ‘Channel Activation’ message.

C10463
Definition

Number of BSC attempts to assign TCH/H (data)


Description
Counter ‘C10463’ represents the number of BSC attempts to assign
TCH/H to the MS in order to carry the user data.
Calculation Formula

Number of BSC attempts to assign TCH/H (data) = Number of


successful TCH/H assignment (data) + Number of unsuccessful TCH/H
assignment (data)
C10463 = C10464 + C10465
Measurement Point
Counter ‘C10463’ increments at the same time with counters ‘C10464’
or ‘C10465’.

C10464
Definition

Number of successful TCH/H assignment (data)


Description
Counter ‘C10464’ represents the number of BSC successfully assigns
TCH/H to the MS in order to carry the user data.
Measurement Point

Counter ‘C10464’ increments when BSC receives ‘Establish indication’


message from BTS (A3-FIGURE 32).

C10465
Definition

Number of unsuccessful TCH/H assignment (data)


Description

Confidential and Proprietary Information of ZTE CORPORATION 385


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Counter ‘C10465’ represents the number of BSC fails to assign TCH/H


to the MS in order to carry the user data.
Measurement Point
Counter ‘C10465’ increments when BSC receives negative
acknowledgment in response to the ‘Assignment Command’ message.

C10466
Definition

Number of handover attempts for TCH/H (data).


Description
Counter ‘C10466’ represents the number of BSC attempts to handover
the MS on new TCH/H data channel. Handover involves both intra-cell
and inter-cell handover.
Calculation Formula

Number of handover attempts for TCH/H (data) = Number of


successful TCH/H handover (data) + Number of unsuccessful TCH/H
handover (data)
C10466 = C10467 + C10468
Measurement Point

Counter ‘C10466’ has the measurement point same like counter


‘C10467’ or counter ‘C10468’.

C10467
Definition

Number of successful TCH/H handover (data)


Description

Counter ‘C10467’ represents the number of BSC receives signaling


about handover success on the new TCH/H data channel. Handover
involves both intra-cell and inter-cell handover.
Measurement Point
Counter ‘C10467” increments when BSC receives ‘Assignment
Complete’ (intra-cell handover) or ‘Handover Complete’ message
(inter-cell handover) on the new TCH/H data channel. Refer to FIGURE
34-C3 and FIGURE 35-D3.

C10468
Definition

Number of unsuccessful TCH/H handover (data)


Description

386 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 27 - TCH/H Measurement

Counter ‘C10468’ represents the number of BSC fails to receive


signaling about handover success on the new TCH/H data channel.
Handover involves both intra-cell and inter-cell handover.
Measurement Point
Counter ‘C10468” increments when BSC receives ‘Handover Fail’
message (inter-cell handover) on old TCH/H.

C10469
Definition

Number of BSC does not receives ‘Handover Fail’ message on the


TCH/H (data)
Description

Not Implemented
Measurement Point
Not Implemented

Confidential and Proprietary Information of ZTE CORPORATION 387


This page is intentionally blank.

388 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 28

Half Rate Statistics

This chapter provides statistics for the HR related services and resources.
Most counters in this chapter depend upon the sum of the other counter
values from the previous chapter. Table 43 lists all the HR Measurement
Counters and their definition.

This Chapter covers the following topics:

HR Measurement Counters

HR Measurement Counters
TABLE 43 HR MEASUREMENT COUNTERS

Counter No. Definition


C11901 Total number of available TCH/Hs
C11902 Total number of unavailable TCH/Hs
C11903 Total number of requests for TCH/H (assignment)
C11904 Total number of unsuccessful TCH/H assignment request
C11905 Total number of requests for TCH/H
C11906 Total number of unsuccessful TCH/H request
C11907 Total number of successful TCH/H assignment
C11908 Total number of successful requests for TCH/H
C11909 Total number of TCH/H call drops
C11910 Total TCH/H busy time
C11911 Number of call drop occurs due to the TCH/H wireless link failure
C11912 Number of call drop occurs due to TCH/H LAPD link failure
C11913 Number of call drop occurs due to TCH/H handover failure
C11914 Maximum number of busy TCH/Hs
C11915 Mean number of busy TCH/Hs

Confidential and Proprietary Information of ZTE CORPORATION 389


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C11916 Total TCH/H congestion time


C11917 Total number of successful TCH/H allocation (assignment)
C11918 Total number of unsuccessful TCH/H allocation (assignment)
C11919 Total number of successful TCH/H allocation
C11920 Total number of unsuccessful TCH/H allocation
C11921 Total number of successful TCH/H assignment
C11922 Total number of unsuccessful TCH/H assignment
C11923 Total number of successful TCH/H handover
C11924 Total number of unsuccessful TCH/H handover
Total number of BSC does not receives ‘Handover Fail’ message on the
C11925
TCH/H
C11926 Mean number of idle TCH/Hs with interference band as 1
C11927 Mean number of idle TCH/Hs with interference band as 2
C11928 Mean number of idle TCH/Hs with interference band as 3
C11929 Mean number of idle TCH/Hs with interference band as 4
C11930 Mean number of idle TCH/Hs with interference band as 5
Number of handover attempts on TCH/H due to better uplink receiving
C11931
strength the target cell
Number of handover attempts on TCH/H due to better downlink receiving
C11932
strength the target cell
Number of handover attempts on TCH/H due to uplink interference in the
C11933
serving cell.
Number of handover attempts on TCH/H due to downlink interference in
C11934
the serving cell.
Number of handover attempts on TCH/H due to C/I RATIO concentric
C11935
circle
C11936 Number of handover attempts on TCH/H due to PBGT
C11937 Number of handover attempts on TCH/H due to large TA
C11938 Number of handover attempts on TCH/H due to better uplink quality in
the target cell.
C11939 Number of handover attempts on TCH/H due to better downlink quality in
the target cell.
C11940 Number of handover attempts on TCH/H due to other factors
C11941 Number of handover (intra-cell) attempts from serving TCH/F to target
TCH/H
C11942 Number of handover (intra-cell) attempts from serving TCH/F to target
TCH/F
C11943 Number of successful handover (intra-cell) from serving TCH/F to target
TCH/F
C11944 Number of handover execution (intra-cell) from serving TCH/F to target
TCH/H
C11945 Number of successful handovers (intra-cell) from serving TCH/F to target
TCH/H

390 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 28 - Half Rate Statistics

C11946 Total number of TCH/H handover (intra-cell) attempts.


Number of handover execution (intra-cell) from serving TCH/H to target
C11947
TCH/F
Number of successful handovers (intra-cell) between serving TCH/H to
C11948
target TCH/F
C11949 Number of handover (intra-cell) execution between TCH/Hs
C11950 Number of successful handovers (intra-cell) between TCH/Hs
Number of handover (inter-cell) attempts from TCH/F to any channel in
C11951
the target cell.
C11952 Number of handover (inter-cell) execution between TCH/Hs
C11953 Number of successful handovers (inter-cell) between TCH/Fs
Number of handover execution (inter-cell) from serving TCH/F to target
C11954
TCH/H
Number of successful handover (inter-cell) from serving TCH/F to target
C11955
TCH/H
Number of handover (inter-cell) attempts from TCH/H to any channel in
C11956
the target cell.
Number of handover execution (inter-cell) from serving TCH/H to target
C11957
TCH/F
Number of successful handover (inter-cell) from serving TCH/H to target
C11958
TCH/F
C11959 Number of handover (inter-cell) execution between TCH/Hs
Number of DTAP messages used for point-to-point short messages on
C11961
uplink FACCH/H
Number of DTAP messages used for point-to-point short messages on
C11962
downlink FACCH/H
Number of DTAP messages used for point-to-point short messages on
C11963
uplink SACCH/F
Number of DTAP messages used for point-to-point short messages on
C11964
downlink SACCH/F
C11965 Number of DTAP messages used for point-to-point short messages on
uplink SACCH/H
C11966 Number of DTAP messages used for point-to-point short messages on
downlink SACCH/H
C11967 Number of successful handover from TCH full rate to TCH half rate.
C11968 Number of successful handover from TCH half rate to TCH full rate.
C11969 Number of handover from TCH full rate to TCH half rate fails.
C11970 Number of handover from TCH half rate to TCH full rate fails.
C11971 Mean number of HR channels
C11972 Maximum number of HR channels
C11973 Minimum number of HR channels

Confidential and Proprietary Information of ZTE CORPORATION 391


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

HR Measurement Counters Explanation


C11901
Definition

Total number of available TCH/Hs


Description

Refer to the description of Counter C11507 in Section Explanation of


Measurement Counters
Calculation formula

C11901 = C11507

C11902
Definition

Total number of unavailable TCH/Hs


Description

Refer to the description of Counter C11508 in Section Explanation of


Measurement Counters
Calculation formula

C11901 = C11508

C11903
Definition

Total number of requests for TCH/H (assignment)


Description

Counter ‘C11903’ represents the total number of requests for TCH/H


assignment as a:
Signalling Channel
Voice Channel
Data Channel
Calculation formula

C11903 = C10401 + C10420 + C10451

C11904
Definition

Total number of unsuccessful TCH/H assignment request

392 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 28 - Half Rate Statistics

Description
Counter ‘C11904’ represents the total number of BSC fails to assign
TCH/H as a:
Signalling Channel
Voice Channel
Data Channel
Calculation formula

C11904 = C10403 + C10422 + C10453

C11905
Definition

Total number of requests for TCH/H


Description

Counter ‘C11905’ represents the total number of TCH/H signal, voice


and data requests fails in case of both assignment and handover,
Calculation formula

C11905 = C11903 + C10404+ C10423 + C10454

C11906
Definition

Total number of unsuccessful TCH/H request


Description

Counter ‘C11906’ represents the total number of request for TCH/H


signal, voice and data fails in case of both assignment and handover.
Calculation formula

C11906 = C11904 + C10406+ C10425 + C10456

C11907
Definition

Total number of successful TCH/H assignment


Description
Counter ‘C11907’ represents the total number of TCH/H signal, voice
and data assignments succeed in case of TCH assignment.
Calculation formula

C11907 = C10402 + C10421 + C10452

Confidential and Proprietary Information of ZTE CORPORATION 393


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C11908
Definition

Total number of successful requests for TCH/H


Description

Counter ‘C11908’ represents the total number of TCH/H signal, voice


and data assignments succeed in case of both TCH assignment and
handover.
Calculation formula

C11908 = C11907 + C10405+ C10424 + C10455

C11909
Definition
Total number of TCH/H call drops
Description

Counter ‘C11909’ represents the total number of TCH/H call drop occurs
due to all the causes.
Calculation formula

C11909 = C10645

C11910
Definition

Total TCH/H busy time


Description

Counter ‘C11910’ represents the total busy time of the TCH/H.


Calculation formula

C11910 = C11511

C11911
Definition

Number of call drop occurs due to the TCH/H wireless link failure
Description

Counter ‘C11911’ represents the number of call drops for TCH signal,
voice and data channels due to wireless link failure.
Calculation formula

C11911 = C10626 + C10632 + C10638

394 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 28 - Half Rate Statistics

C11912
Definition

Number of call drop occurs due to TCH/H LAPD link failure


Description

Counter ‘C11912’ represents the number of call drops for TCH signal,
voice and data channels due to LAPD link failure
Calculation formula

C11912 = C10627 + C10633 + C10639

C11913
Definition

Number of call drop occurs due to TCH/H handover failure


Description

Counter ‘C11913’ represents the number of call drops for TCH signal,
voice and data channels due to handover failure
Calculation formula

C11913 = C10650 + C10651 + C10652

C11914
Definition

Maximum number of busy TCH/Hs


Description

Counter ‘C11914’ represents the maximum number of seize TCH/Hs


Calculation formula

C11914 = C11509

C11915
Definition

Mean number of busy TCH/Hs


Description

Counter ‘C11915’ represents the Mean number of seize TCH/Hs


Calculation formula

C11915 = C11510

Confidential and Proprietary Information of ZTE CORPORATION 395


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C11916
Definition

Total TCH/H congestion time


Description

Counter ‘C11916’ represents the total congestion time of TCH/H.


Calculation formula

C11916 = C11512

C11917
Definition

Total number of successful TCH/H allocation (assignment)


Description

Counter ‘C11917’ represents the total number of BSC successfully


allocates the TCH/H signal, voice (V.1, V.2 and V.3) and data channels
for the assignment purpose.
Calculation formula

C11917 = C10408+ C10427+ C10433+ C10439+ C10458

C11918
Definition

Total number of unsuccessful TCH/H allocation (assignment)


Description

Counter ‘C11918’ represents the total number of BSC fails to allocate


the TCH/H signal, voice (V.1, V.2 and V.3) and data channels for the
assignment purpose.
Calculation formula

C11918 = C10409+ C10428+ C10434+ C10440+ C10459

C11919
Definition

Total number of successful TCH/H allocation


Description

Counter ‘C11919’ represents the total number of BSC successfully


allocates the TCH/H signal, voice (V.1, V.2 and V.3) and data channels
in case of both assignment and handover.

396 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 28 - Half Rate Statistics

Calculation formula

C11919 = C11917 + C10411+ C10430+ C10436+ C10442+ C10461

C11920
Definition

Total number of unsuccessful TCH/H allocation


Description

Counter ‘C11920’ represents the total number of BSC fails to allocate


the TCH/H signal, voice (V.1, V.2 and V.3) and data channels in case of
both assignment and handover.
Calculation formula

C11920 = C11918 + C10412+ C10431+ C10437+ C10443+ C10462

C11921
Definition

Total number of successful TCH/H assignment


Description

Counter ‘C11921’ represents the total number of BSC successfully


assigns the TCH/H signal, voice and data channels.
Calculation formula

C11921 = C10414 + C10445 + C10464

C11922
Definition

Total number of unsuccessful TCH/H assignment


Description

Counter ‘C11922’ represents the total number of BSC fails to assigns


the TCH/H signal, voice and data channels.
Calculation formula

C11922 = C10415 + C10446 + C10465

C11923
Definition

Total number of successful TCH/H handover

Confidential and Proprietary Information of ZTE CORPORATION 397


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Description

Counter ‘C1192’ represents the total number of BSC successfully


handovers the MS to the new TCH/H signal, voice and data channels.
Calculation formula

C11923 = C10417 + C10448 + C10467

C11924
Definition

Total number of unsuccessful TCH/H handover


Description

Counter ‘C1124’ represents the total number of BSC fails to handover


the MS to the new TCH/H signal, voice and data channels.
Calculation formula

C11924 = C10418 + C10449 + C10468

C10425
Definition

Total number of BSC does not receives ‘Handover Fail’ message on the
TCH/H
Calculation formula

C11925 = C10419 + C10450 + C10469

C11926
Definition

Mean number of idle TCH/Hs with interference band as 1


Description
Refer to the description of Counter C10725 in Section Channels
Counters Explanation.
Calculation formula
C11926 = C10725

C11927
Definition

Mean number of idle TCH/Hs with interference band as 2


Description

Refer to the description of Counter C10726 in Section Channels


Counters Explanation.

398 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 28 - Half Rate Statistics

Calculation formula

C11927 = C10726

C11928
Definition
Mean number of idle TCH/Hs with interference band as 3
Description

Refer to the description of Counter C10727 in Section Channels


Counters Explanation.
Calculation formula
C11928 = C10727

C11929
Definition

Mean number of idle TCH/Hs with interference band as 4


Description

Refer to the description of Counter C10728 in Section Channels


Counters Explanation.
Calculation formula

C11929 = C10728

C11930
Definition

Mean number of idle TCH/Hs with interference band as 5


Description

Refer to the description of Counter C10729 in Section Channels


Counters Explanation.
Calculation formula

C11930 = C10729

C11931
Definition

Number of handover attempts on TCH/H due to better uplink receiving


strength the target cell
Calculation formula

C11931 = C10822

Confidential and Proprietary Information of ZTE CORPORATION 399


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C11932
Definition

Number of handover attempts on TCH/H due to better downlink


receiving strength the target cell
Calculation formula

C11932 = C10823

C11933
Definition

Number of handover attempts on TCH/H due to uplink interference in


the serving cell.
Description

Counter ‘C11933’ represents the number of BSC attempts to handover


(External and Internal) the MS on new TCH/H. Cause of handover is
the interference in the uplink channel of the serving cell.
Calculation formula

C11933 = C10824

C11934
Definition

Number of handover attempts on TCH/H due to downlink interference


in the serving cell.
Description

Counter ‘C11934’ represents the number of BSC attempts to handover


(External and Internal) the MS on new TCH/H. Cause of handover is
the interference in the downlink channel of the serving cell.
Calculation formula

C11934 = C10825

C11935
Definition

Number of handover attempts on TCH/H due to C/I RATIO concentric


circle
Description

Counter ‘C11935’ represents the number of BSC attempts to handover


(External and Internal) the MS on new TCH/H. Cause of handover is
large C/I RATIO in the serving TCH/H.
Calculation formula

400 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 28 - Half Rate Statistics

C11935 = C10826

C11936
Definition

Number of handover attempts on TCH/H due to PBGT


Description

Refer to the description of Counter in Section Handover Cause


Counters Explanation.
Calculation formula
C11936 = C10827

C11937
Definition

Number of handover attempts on TCH/H due to large TA


Description

Refer to the description of Counter in Section Handover Cause


Counters Explanation.
Calculation formula

C11937 = C10828

C11938
Definition
Number of handover attempts on TCH/H due to better uplink quality in
the target cell.
Description

Refer to the description of Counter Section Handover Cause Counters


Explanation.
Calculation formula

C11938 = C10839

C11939
Definition

Number of handover attempts on TCH/H due to better downlink quality


in the target cell.
Description

Refer to the description of Counter Section Handover Cause Counters


Explanation.

Confidential and Proprietary Information of ZTE CORPORATION 401


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Calculation formula

C11939 = C10840

C11940
Definition

Number of handover attempts on TCH/H due to other factors


Description

Other factors such as traffic, rapid drop and fast movement


Calculation formula

C11940 = C10831

C11941
Definition

Number of handover (intra-cell) attempts from serving TCH/F to target


TCH/H
Description

Refer to the description of Counter in Section Handover Cause


Counters Explanation.
Calculation formula

C11941 = C10999

C11942
Definition

Number of handover (intra-cell) attempts from serving TCH/F to target


TCH/F
Description

Not Required in HR Statistics


Calculation formula

C11942 = C109100

C11943
Definition

Number of successful handover (intra-cell) from serving TCH/F to


target TCH/F
Description

Not Required in HR Statistics

402 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 28 - Half Rate Statistics

Calculation formula

C11943 = C109101

C11944
Definition

Number of handover execution (intra-cell) from serving TCH/F to


target TCH/H
Description

Refer to the description of Counter C109102 in Section Handover


Counters Explanation.
Calculation formula

C11944 = C109102

C11945
Definition

Number of successful handover (intra-cell) from serving TCH/F to


target TCH/H
Description

Refer to the description of Counter C109103 in Section Handover


Counters Explanation.
Calculation formula

C11945 = C109103

C11946
Definition

Total number of TCH/H handover (intra-cell) attempts.


Description

Refer to the description of Counter C109104 in Section Handover


Counters Explanation.
Calculation formula

C11946 = C109104

C11947
Definition

Number of handover execution (intra-cell) from serving TCH/H to


target TCH/F
Description

Confidential and Proprietary Information of ZTE CORPORATION 403


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Refer to the description of Counter C109105 in Section Handover


Counters Explanation.
Calculation formula

C11947 = C109105

C11948
Definition

Number of successful handovers (intra-cell) between serving TCH/H to


target TCH/F
Description

Refer to the description of Counter C109106 in Section Handover


Counters Explanation.
Calculation formula

C11948 = C109106

C11949
Definition

Number of handover (intra-cell) execution between TCH/Hs


Description

Refer to the description of Counter C109107 in Section Handover


Counters Explanation.
Calculation formula

C11949 = C109107

C11950
Definition

Number of successful handovers (intra-cell) between TCH/Hs


Description

Refer to the description of Counter C109108 in Section Handover


Counters Explanation.
Calculation formula

C11950 = C109108

C11951
Definition

Number of handover (inter-cell) attempts from TCH/F to any channel in


the target cell.

404 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 28 - Half Rate Statistics

Description

Refer to the description of Counter C109109 in Section Handover


Counters Explanation.
Calculation formula

C11951 = C109109

C11952
Definition

Number of handover (inter-cell) execution between TCH/Hs


Description

Refer to the description of Counter C109110 in Section Handover


Counters Explanation.
Calculation formula

C11952 = C109110

C11953
Definition

Number of successful handover (inter-cell) between TCH/Fs


Description

Refer to the description of Counter C109111 in Section Handover


Counters Explanation.
Calculation formula

C11953 = C109111

C11954
Definition

Number of handover execution (inter-cell) from serving TCH/F to


target TCH/H
Description

Refer to the description of Counter C109112 in Section Handover


Counters Explanation.
Calculation formula

C11954 = C109112

C11955
Definition

Confidential and Proprietary Information of ZTE CORPORATION 405


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Number of successful handover (inter-cell) from serving TCH/F to


target TCH/H
Description

Refer to the description of Counter C109113 in Section Handover


Counters Explanation.
Calculation formula

C11955 = C109113

C11956
Definition

Number of handover (inter-cell) attempts from TCH/H to any channel


in the target cell.
Description

Refer to the description of Counter C109114 in Section Handover


Counters Explanation.
Calculation formula

C11956 = C109114

C11957
Definition

Number of handover execution (inter-cell) from serving TCH/H to


target TCH/F
Description

Refer to the description of Counter C109115 in Section Handover


Counters Explanation.
Calculation formula

C11957 = C109115

C11958
Definition

Number of successful handover (inter-cell) from serving TCH/H to


target TCH/F
Description

Refer to the description of Counter C109116 in Section Handover


Counters Explanation.
Calculation formula

C11958 = C109116

406 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 28 - Half Rate Statistics

C11959
Definition
Number of handover (inter-cell) execution between TCH/Hs
Description
Refer to the description of Counter C109117 in Section Handover
Counters Explanation.
Calculation formula

C11959 = C109117

C11960
Definition

Number of successful handover (inter-cell) between TCH/Hs


Description

Refer to the description of Counter C109118 in Section Handover


Counters Explanation.
Calculation formula

C11960 = C109118

C11961
Definition

Number of DTAP messages used for point-to-point short messages on


uplink FACCH/H
Description

Refer to the description of Counter C10220 in Section SAPI 3 Counters


Explanation.
Calculation formula

C11961 = C10220

C11962
Definition

Number of DTAP messages used for point-to-point short messages on


downlink FACCH/H
Description

Refer to the description of Counter C10221 in Section SAPI 3 Counters


Explanation.
Calculation formula

Confidential and Proprietary Information of ZTE CORPORATION 407


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C11962 = C10221

C11963
Definition

Number of DTAP messages used for point-to-point short messages on


uplink SACCH/F
Description

Refer to the description of Counter C10222 in Section SAPI 3 Counters


Explanation.
Calculation formula

C11963 = C10222

C11964
Definition

Number of DTAP messages used for point-to-point short messages on


downlink SACCH/F
Description

Refer to the description of Counter C10223 in Section SAPI 3 Counters


Explanation.
Calculation formula

C11964 = C10223

C11965
Definition

Number of DTAP messages used for point-to-point short messages on


uplink SACCH/H
Description

Refer to the description of Counter C10224 in Section SAPI 3 Counters


Explanation.
Calculation formula

C11965 = C10224

C11966
Definition

Number of DTAP messages used for point-to-point short messages on


downlink SACCH/H
Description

408 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 28 - Half Rate Statistics

Refer to the description of Counter C10225 in Section SAPI 3 Counters


Explanation.
Calculation formula

C11966 = C10225

C11967
Definition

Number of successful handovers from TCH full rate to TCH half rate
Description

The system triggers TCH/F-TCH/H conversion process according to the


set threshold. And TCH/F and TCH/H quantity counted in real time.
FIGURE 36 illustrates the conversion process.

FIGURE 36 - CONVERSIONS FROM TCH/F TO TCH/H

BTS Agt Pn ExchangeProc P0 ExchangeProc

EV _ DYN _ CHANGE _ REQ

EV _ BTS _ DATA

EV _ BTS _ DATA _ ACK

EV _P0_ DATA

Modify Po database
EV _P0_ ACK

Modify Pn database

Measurement point

Counter ‘C11967’ increments when RMM receives the EV_P0_ACK


message during the TCHF_TO_TCHH conversion process.

C11968
Definition

Number of successful handover from TCH half rate to TCH full rate.
Description

Handover process in this case is opposite to the one described in


Counter C11967.

Confidential and Proprietary Information of ZTE CORPORATION 409


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Measurement point

Counting when RMM receives the EV_P0_ACK message during


TCHH_TO_TCHF conversion process.

C11969
Definition

Number of handover from TCH full rate to TCH half rate fails.
Description

Handover fails if Conversion from TCHF to TCHH is unsuccessful.


Measurement point

Counter ‘C11969’ increments if RMM does not receive the


EV_BTS_DATA_ACK or EV_P0_ACK message within specified time.

C11970
Definition

Number of handover from TCH half rate to TCH full rate fails.
Description

Handover fails if Conversion from TCHH to TCHF is unsuccessful.


Measurement point

Counter ‘C11970’ increments if RMM does not receive the


EV_BTS_DATA_ACK or EV_P0_ACK message within specified time.

C11971
Definition

Mean number of HR channels


Description

Counter ‘C11971’ represents the Mean number of TCH/Hs in the cell.


Mean number of TCH/Hs includes all the available and unavailable
TCH/Hs.
Measurement point
Querying the database during periodic measurements

C11972
Definition

Maximum number of HR channels


Description

410 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 28 - Half Rate Statistics

Omitted

C11973
Definition

Minimum number of HR channels


Description
Omitted

Confidential and Proprietary Information of ZTE CORPORATION 411


This page is intentionally blank.

412 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 29

Reserved Channel
Measurement

This chapter covers the following topics:

Reserved Channel Counters

Reserved Channel Counters


These counters provide statistics of reserved channels Allocation in case of
assignment, internal handover, and external handover-in.

TABLE 44 COUNTERS FOR RESERVED CHANNELS

Counter No. Definition


Number of allocations of reserved full rate channel in assignment
C10470
(voice)
Number of allocations of reserved full rate channel in assignment
C10471
(data)
Number of allocations of reserved full rate channel in handover
C10472
(voice)
Number of allocations of reserved full rate channel in handover
C10473
(data)

Reserved Channel Counters Explanation


C10470
Definition

Number of allocations of reserved full rate channel in assignment


(voice)

Confidential and Proprietary Information of ZTE CORPORATION 413


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Description

C10470 represents number of reserved full rate voice channel


activations for assignment. It also includes successful channel
activations after queuing.
Measurement Point

C10470 increments after each single successful reserved channel


activation. (B1 in FIGURE 33)

C10471
Definition

Number of allocations of reserved full rate channel in assignment (data)


Description

C10471 represents number of reserved full rate data channel


activations for assignment. It also includes successful channel
activations after queuing.
Measurement Point

C10471 increments after each single successful reserved channel


activation. (B1 in FIGURE 33)

C10472
Definition

Number of allocating the reserved full rate channel in handover (voice)


Description

C10472 represents number of reserved full rate voice channel


activations for handover. It also includes successful channel activations
after queuing or force release.
Measurement Point

C10472 increments after each single successful reserved channel


activation. (C1 in FIGURE 34 D1 in FIGURE 35)

C10473
Definition

Number of allocating the reserved full rate channel in handover (data)


Description

C10473 represents number of reserved full rate data channel


activations for handover. It also includes successful channel activations
after queuing or force release.

414 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 29 - Reserved Channel Measurement

Measurement Point

C10473 increments after each single successful reserved channel


activation. (C1 in FIGURE 34 & D1 in FIGURE 35 )

Confidential and Proprietary Information of ZTE CORPORATION 415


This page is intentionally blank.

416 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30

Packet Switched Service


Measurement

This Chapter covers the following topics:

PS Basic Measurement Counters

NS Sub Layer Counters


BSSGP Layer Counters
NSE Performance Statistic Counters
PS Traffic Counters
Resource Management Counters

PS Basic Measurement Counters


The PS basic measurement counters are of two types:

Cell Counters
BSC Counters
Cell Counters: PS Basic Measurement Counters that relates to cell.

BSC Counters: PS Basic Measurement Counters that relates to BSC.

Table 45 lists all the PS basic measurement counters that take cell as
measurement unit.

TABLE 45 PS BASIC MEASUREMENT COUNTERS – CELL AS THE UNIT

Counter
Definition
Number.
C70001 Number of “Packet paging” that BSC initiates
C70002 Number of “Circuit paging” that BSC initiates
C70003 Number of used PPCH

Confidential and Proprietary Information of ZTE CORPORATION 417


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Counter
Definition
Number.
C70004 Total number of PRACH
C70005 Number of used PAGCH
C70006 Number of conversion from CS1 to CS2
C70007 Number of conversion from CS2 to CS1
C70008 Uplink power control
C70009 Number of forced retracting dynamic PDCH by BSC
C70010 Number of successfully activating dynamic PDCH
C70011 Number of failed activating dynamic PDCH
C70012 Number of PDCH failure
C70013 Number of PDCH failure recovery
C70014 Number of packet messages waiting to be send on PCH-AGCH
C70015 Number of assignment messages waiting to be send on PPCH-PAGCH
C70016 Number of paging messages deleted from PCH queue
C70017 Number of packet paging messages deleted from PPCH queue
C70018 Number of failed transmitted paging messages from the cell
C70019 Average number of available PDCH
C70020 Average number of occupied PDCH
C70021 Maximum number of occupied PDCH
C70022 Minimum number of occupied PDCH
C70023 Average number of messages in PCH-AGCH queue
C70024 Average number of messages in PPCH-PAGCH queue
Number of failed attempts of requesting packet channel due to number
C70025
available channels
C70026 Number of “DOWNLOAD-BSS-PFC” message that BSS sends

C70027 Number of “CREATE-BSS-PFC” message that BSS receives

C70028 Number of “CREATE-BSS-PFC-ACK” message that BSS sends

C70029 Number of “CREATE-BSS-PFC-NACK” message that BSS sends

C70030 Number of “MODIFY-BSS-PFC” message that BSS sends

C70031 Number of “MODIFY-BSS-PFC-ACK” message that BSS receives

C70032 Number of “DELETE-BSS-PFC” message that BSS receives

C70033 Number of “DELETE-BSS-PFC-ACK” message that BSS sends

C70034 Number of attempt of increasing timeslot of dynamic Abis-interface


C70035 Number of successful increasing timeslot of dynamic Abis-interface
C70036 Number of attempt of decreasing timeslot of dynamic Abis-interface
C70037 Number of successful decreasing timeslot of dynamic Abis-interface
C70038 Total number of adjusting uplink packet channel frame Number

418 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

Counter
Definition
Number.
C70039 Total number of adjusting downlink packet channel frame Number.
C70040 Total number of requesting uplink packet channel
C70041 Total number of requesting downlink packet channel
C70042 Total number of uplink signaling TBF link establishment
C70043 Total number of downlink signaling TBF link establishment
C70044 Total number of data blocks received by packet uplink channel
C70045 Total number of signaling blocks received by packet uplink channel
C70046 Total number of signaling blocks that packet downlink channel sends
C70047 Total number of data blocks that packet downlink channel sends
C70048 Total number of data blocks sending according to given Abis bandwidth
Total bytes of effective upper layer protocol data sent by packet downlink
C70049
channel
Total bytes of effective upper layer protocol data received by packet
C70050
uplink channel
C70051 Number of uplink GPRS TBF existing simultaneously in the cell
C70052 Number of downlink GPRS TBF existing simultaneously in the cell
C70053 Number of uplink EGPRS TBF existing simultaneously in the cell
C70054 Number of downlink EGPRS TBF existing simultaneously in the cell
C70055 Total number of GPRS uplink data TBF link establishment
C70056 Total number of establishing GPRS uplink data TBF on PACCH
C70057 Total number of GPRS downlink data TBF link establishment
C70058 Total number of establishing GPRS downlink data TBF on PACCH
C70059 Total data quantity carried by GPRS uplink data TBF
C70060 Total number of completion of GPRS uplink data TBF
C70061 Total duration of GPRS uplink data TBF
C70062 Total data quantity carried by GPRS downlink data TBF
C70063 Total number of completion of GPRS downlink data TBF
C70064 Total duration of GPRS downlink data TBF
C70065 Total number of effective data blocks received by GPRS uplink TBF
C70066 Total number of GPRS uplink TBF NACK blocks
C70067 Total number of effective data blocks that GPRS downlink TBF sends
C70068 Total number of GPRS downlink TBF NACK blocks
C70069 Total number of EGPRS uplink data TBF link establishment
C70070 Total number of establishing EGPRS uplink data TBF on PACCH
C70071 Total number of EGPRS downlink data TBF link establishment
C70072 Total number of establishing EGPRS downlink data TBF on PACCH
C70073 Total data quantity carried by EGPRS uplink data TBF

Confidential and Proprietary Information of ZTE CORPORATION 419


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Counter
Definition
Number.
C70074 Total number of completion of EGPRS uplink data TBF
C70075 Total duration of EGPRS uplink data TBF
C70076 Total Number of data carried by EGPRS downlink data TBF
C70077 Total number of completion of EGPRS downlink data TBF
C70078 Total duration of EGPRS downlink data TBF
C70079 Total number of effective data blocks received by EGPRS uplink TBF
C70080 Total number of EGPRS uplink TBF NACK blocks
Total number of data blocks sent by EGPRS downlink TBF (except for
C70081
Pending ACK block)
C70082 Total number of EGPRS downlink TBF NACK blocks
C70083 Total number of downlink signaling LLC frame packets
C70084 Total number of discarded downlink signaling LLC frame packets
C70085 Total number of downlink GPRS data frame packets
C70086 Total number of discarded downlink GPRS data frame packets
C70087 Total number of downlink EGPRS data frame packets
C70088 Total number of discarded downlink EGPRS data frame packets
C70089 Number of stale GPRS uplink TBF window
C70090 Number of stale EGPRS uplink TBF window
C70091 Number of stale GPRS downlink TBF window
C70092 Number of stale EGPRS downlink TBF window
C70093 Total number of abnormal release of uplink signaling TBF
C70094 Total number of abnormal release of uplink GPRS data TBF
C70095 Total number of abnormal release of uplink EGPRS data TBF
C70096 Total number of abnormal release of downlink signaling TBF
C70097 Total number of abnormal release of downlink GPRS data TBF
C70098 Total number of abnormal release of downlink EGPRS data TBF
C70099 Number of requests for increasing Abis bandwidth by uplink TBF
C70100 Number of requests for increasing Abis bandwidth by downlink TBF
C70101 Number of handover from GMSK to 8PSK
C70102 Number of handover from 8PSK to GMSK
C70103 Number of handover from CS1, 2 to CS3, 4
C70104 Number of handover from CS3, 4 to CS1, 2
C70105 Total number of data packets send to peripheral modules by BRP
C70106 Total number of data packets that BRP receives from peripheral modules
C70107 Total number of data packets send to BRP by peripheral modules
Total number of data packets received by peripheral modules that are
C70108
sent by BRP

420 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

Counter
Definition
Number.
C70109 Number of outgoing handover from cell
C70110 Number of handover-in cell
C70111 Total number of CS1 data blocks received by packet uplink channel
C70112 Total number of CS2 data blocks received by packet uplink channel
C70113 Total number of CS3 data blocks received by packet uplink channel
C70114 Total number of CS4 data blocks received by packet uplink channel
C70115 Total number of CS1 data blocks received by packet downlink channel
C70116 Total number of CS2 data blocks received by packet downlink channel
C70117 Total number of CS3 data blocks received by packet downlink channel
C70118 Total number of CS4 data blocks received by packet downlink channel
C70119 Minimum number of available PDCH
Total number of uplink blocks received by uplink channel (including
C70120
DUMMY block)
Total number of downlink blocks sent by downlink channel (including
C70121
DUMMY block)

Table 46 lists all the PS Basic Measurement Counters that take BSC as
measurement unit.

TABLE 46 COUNTERS FOR PS BASIC MEASUREMENT – BSC AS UNIT

Counter
Definition
Number.
C90001 Total number of uplink data packets carried by BRCH
C90002 Total number of downlink data packets carried by BRCH
C90003 Number of interruption due to BRCH receiving failure
C90004 Total number of data packets send to FRP by BRP
C90005 Total number of data packets received by BRP that are sent by FRP
C90006 Total number of data packets send to BRP by FRP
C90007 Total number of data packets received by FRP that are sent by BRP

PS Basic Measurement Counters


Explanation
C70001
Definition

Number of “Packet paging” that BSC initiates


Description

Confidential and Proprietary Information of ZTE CORPORATION 421


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C70001 represents number of “Packet paging” that BSC initiates. The


paging message comes through Gb interface.
Measurement Point

C70001 increments when BSC receives packet paging message on PTP.

C70002
Definition

Number of “Circuit paging” that BSC initiates


Description

C70003 represents number of “Circuit paging” that BSC initiates.


Paging message comes through Gb interface.
Measurement Point

C70003 accumulates one every time BSC receives on PTP circuit


paging message.

C70003
Definition

Number of used PPCH


Description

C70003 represents number of PPCH in cell, currently in use during


statistic period.
Measurement Point

C70004 increments when BSC uses PPCH to send paging message or


implements downlink assignment.

C70004
Definition

Number of used PRACH


Description

C70004 represents number of PRACH in cell, currently in use during


statistic period.
Measurement Point

C70004 increments when BSC receives uplink request send on PRACH.

C70005
Definition

Number of used PAGCH

422 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

Description

C70005 represents number of PAGCH in cell, currently in use during


statistic period.
Measurement Point

C70005 increments when BSC uses PAGCH to send uplink assignment


message.

C70006
Definition

Number of conversions from CS1 to CS2


Description

C70006 represents number of TBF coding scheme’s conversion from


CS1 to CS2.
Measurement Point

C70006 increments when BSC initiates a conversion from CS1 to CS2


according to current channel status and wireless environment.

C70007
Definition

Number of conversion from CS2 to CS1


Description

C70007 represents number of TBF coding scheme’s conversion from


CS2 to CS1.
Measurement Point

C70007 increments when BSC initiates a conversion from CS2 to CS1


according to current channel status and wireless environment.

C70008
Definition

Uplink power control


Description

C70008 represents number of uplink power control of mobile phone


implementations during uplink TBF process in cell by BSC.
Measurement Point

C70008 increments every time BSC initiates an uplink power control


according to the current channel status.

Confidential and Proprietary Information of ZTE CORPORATION 423


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C70009
Definition

Number of forced retractions of dynamic PDCH by BSC


Description

C70009 represents number of dynamic channel conversions from


PDTCH to TCH by BSC.
Measurement Point

C70010 increments when BSC converts dynamic channel from PDTCH


to TCH successfully.

C70010
Definition

Number of successful activations of dynamic PDCH


Description

C70010 represents number of successful conversions from TCH to


dynamic PDTCH
Measurement Point

C70010 increments when BSC converts dynamic channel from TCH to


PDTCH successfully.

C70011
Definition

Number of failed dynamic PDCH activations


Description

C70011 represents number of failed conversions from dynamic TCH to


PDTCH
Measurement Point

C70011 increments when dynamic channel conversion from TCH to


PDTCH becomes unsuccessfully.

C70012
Definition

Number of PDCH failures


Description

C70012 represents number of PDCH failures when PDTCH is blocked.


Measurement Point

424 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

BSC represents PDCH blocking times and directly writes it to buffer.


C70012 increments every time when PDCH is blocked.

C70013
Definition

Number of PDCH failure recoveries


Description

C70013 represents number of unblocking PDTCH.


Measurement Point

BSC represents PDCH number of unblocks and directly writes it to


buffer. C70014 increments every time when PDCH is unblocked.

C70014
Definition

Numbers of packet messages waiting to be send on PCH-AGCH


Description

C70014 represents number of packet messages waiting to be send on


PCH-AGCH
Measurement Point

C70014 increments every time when BSC sends assignment message


to BTS on CCCH.

C70015
Definition

Numbers of assignment messages waiting to be send on PPCH-PAGCH


Description

C70015 represents number of packet messages waiting to be send on


PCH-PAGCH.
Measurement Point

C70015 increments every time when MP Service module sends


assignment message on PCCCH to BRP.

C70016
Definition

Number of paging messages deleted from PCH queue


Description

Confidential and Proprietary Information of ZTE CORPORATION 425


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C70016 represents average number of paging messages deleted from


PCH queue.
Measurement Point

C70016 increments every time when BTS deletes paging message on


PCH.

C70017
Definition

Number of packet paging messages deleted from PPCH queue


Description

C70017 represents average number of paging messages deleted from


PPCH queue.
Measurement Point

C70017 increments every time when BTS deletes paging message on


PPCH.

C70018
Definition

Number of transmitted paging message failures from cell


Description

C70018 represents number of transmitted paging message failures


from cell.
Measurement Point

C70018 increments every time when BTS fails to transmit paging


message.

C70010
Definition

Average number of available PDCH


Description

C70010 represents average number of available PDCH in cell.


Measurement Point

BSC records samples and directly writes to buffer. Sampling uses


sum/sample rate within five minutes.

C70020
Definition

426 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

Average number of occupied PDCH


Description

C70020 represents average number of occupied PDCH in cell.


Measurement Point

BSC records and directly writes to buffer.

C70021
Definition

Maximum number of occupied PDCH


Description

C70021 represents maximum number of occupied PDCH.


Measurement Point

Service module on Mp records and directly writes to buffer.

C70022
Definition

Minimum number of occupied PDCH


Description

C70022 represents minimum number of occupied PDCH


Measurement Point

Service module on Mp records and directly writes to buffer.

C70023
Definition

Average number of messages in PCH-AGCH queue


Description

C70023 represents average number of messages waiting in a queue,


will be send on PCH-AGCH.
Measurement Point

BTS service module obtains length of the message that queued on


PCH-AGCH at sampling point.

C70024
Definition

Average number of assignment messages in PPCH-PAGCH queue

Confidential and Proprietary Information of ZTE CORPORATION 427


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Description

C70024 represents number of messages waiting in a queue, will be


send on PCH-PAGCH
Measurement Point

BTS service module obtains length of the message that queued on


PPCH-PAGCH at sampling point.

C70025
Description

Number of failed attempts of requesting packet channel due to


unavailability of channels
Definition

C70025 represents average number of packet messages waiting to be


send on PCH-PAGCH
Measurement Point

C70025 increments every time when BSC fails to count requests of


packet channel due to unavailability of channels.

C70026
Definition

Number of DOWNLOAD-BSS-PFC message that BSS sends


Description

C70026 represents number of DOWNLOAD-BSS-PFC message that BSS


sends
Measurement Point

C70026 increments every time Mp service module sends DOWNLOAD-


BSS-PFC message.

C70027
Definition

Number of CREATE-BSS-PFC message that BSS receives


Description

C7007 represents number of CREATE-BSS-PFC message that BSS


receives
Measurement Point

C70027 increments every time when Mp service module receives


CREATE-BSS-PFC message.

428 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

C70028
Definition

Number of CREATE-BSS-PFC-ACK message that BSS sends

Description

C70029 represents number of CREATE-BSS-PFC-ACK message that BSS


sends

Measurement Point

C70029 increments every time when BSC sends CREATE-BSS-PFC-ACK


message.

C70029
Definition

Number of CREATE-BSS-PFC-NACK messages that BSS sends


Description

C70029 represents number of CREATE-BSS-PFC-NACK message send


in cell
Measurement Point

C70029 increments every time when BSC sends CREATE-BSS-PFC-


NACK message.

C70030
Definition

Number of MODIFY-BSS-PFC message that BSS sends


Description

C70030 represents number of MODIFY-BSS-PFC message send in cell


Measurement Point

C70030 increments every time when BSC sends MODIFY-BSS-PFC


message.

C70031
Definition

Number of MODIFY-BSS-PFC-ACK message that BSS receives


Description

C70031 represents number of MODIFY-BSS-PFC-ACK message


received in cell

Confidential and Proprietary Information of ZTE CORPORATION 429


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Measurement Point

C70031 increments every time when BSC sends MODIFY-BSS-PFC-ACK


message.

C70032
Definition

Number of DELETE-BSS-PFC message that BSS receives


Description

C70033 represents number of “DELETE-BSS-PFC” message received in


cell.
Measurement Point

C70033 increments every time when BSC sends DELETE-BSS-PFC


message.

C70033
Definition

Number of DELETE-BSS-PFC-ACK message that BSS sends


Description

C70033 represents number of DELETE-BSS-PFC-ACK message that


BSS sends in cell.
Measurement Point

C70033 increments every time when BSC sends DELETE-BSS-PFC-ACK


message.

C70034
Definition

Number of attempts to increase timeslot of dynamic Abis-interface


Description

C70034 represents number of attempts to expand Abis communication


link.
Measurement Point

C70035 increments every time when BRP service module on PCU


initiates a dynamic Abis-interface expansion.

C70035
Definition

Number of successful increase in timeslot of dynamic Abis-interface

430 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

Description

C70035 represents number of successful expansion of Abis


communication link.
Measurement Point

C70035 increments every time when BRP service module on PCU


successfully initiates a dynamic Abis-interface expansion.

C70036
Definition

Number of attempts to decrease timeslot of dynamic Abis-interface


Description

C70036 represents number of attempts to decrease Abis


communication link.
Measurement Point

C70036 increments every time when BRP service module on PCU


initiates a dynamic Abis-interface reduction.

C70037
Definition

Number of successful decrements in timeslots of dynamic Abis-


interface
Description

C70037 represents number of attempts to decrease Abis


communication link
Measurement Point

C70037 increments every time when BRP service module on PCU


successfully initiates a dynamic Abis-interface reduction.

C70038
Definition

Total number of adjustments of frame number of uplink packet channel


Description

C70038 represents number of adjustments of frame number of uplink


packet channel in cell
Measurement Point

C70038 increments every time when BRP service module on PCU


adjusts frame number of uplink packet channel.

Confidential and Proprietary Information of ZTE CORPORATION 431


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C70039
Definition

Total number of adjustment for frame number of downlink packet


channel
Description

C70040 represents total number of times adjustments for frame


number of downlink packet channel in the cell
Measurement Point

C70039 increments every time when BRP service module on PCU


adjusts frame number of downlink packet channel.

C70040
Definition

Total number of requests for uplink packet channel


Description

C70040 represents total number of requests for uplink packet channel


Measurement Point

C70040 increments every time when MP Service module receives


packet channel request that include BCCH, PBCCH, and PACCH.

C70041
Definition

Total number of requests for downlink packet channel


Description

C70041 represents total number of requests for downlink packet


channel
Measurement Point

C70041 increments every time when MP Service module receives


request for downlink packet channel sent by BRP service module on
PCU.

C70042
Definition

Total number of uplink signaling TBF link establishments


Description

C70042 represents total number of uplink signaling TBF link


establishments

432 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

Measurement Point

C70042 represents every time when MP Service module receives uplink


ONE PHASE access request or TWO PHASE access request. This time
signaling transmission is required in resource request message.

C70043
Definition

Total number of downlink signaling TBF link establishments


Description

C70043 represents total number of uplink signaling TBF link


establishments.
Measurement Point

C70043 increments when MP Service module receives downlink


signaling TBF access request sent by BRP.
BSC judges T bit in downlink LLC frame. If T bit equals to zero, then
downlink signaling TBF access request initiates. If T bit equals to one,
then downlink data TBF link establishment request initiates.

C70044
Definition

Total number of data blocks received by packet uplink channel


Description

C7004 represents number of data blocks received by packet uplink


channel.
Measurement Point

C7004 increments when BSC receives effective uplink data block.


The effective data block refers to uplink data block that is located to
TBF instance.

C70045
Definition

Total number of signaling blocks received by packet uplink channel


Description

C70045 represents total number of signaling blocks received by packet


uplink channel.
Measurement Point

C70045 increments when BSC receives effective uplink signaling block.

Confidential and Proprietary Information of ZTE CORPORATION 433


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

The effective signaling block refers to uplink signaling block that is


located to uplink signaling block.

C70046
Definition

Total number of signaling blocks that packet downlink channel sends


Description

C70046 represents number of signaling blocks sent by packet downlink


channel.
Measurement Point

C70046 increments when BSC successfully sends downlink signaling


block.
Sending downlink-signaling block successfully refers to downlink
signaling block that system writes in channel data buffer successfully.
Downlink signaling block does not include PACKET DUMMY CONTROL
message.

C70047
Definition

Total number of data blocks that packet downlink channel sends


Description

C70047 represents total number of data blocks sent by packet


downlink channel.
Measurement Point

C70047 increments when BRP service module successfully sends


downlink data block.
Sending downlink data block successfully refers to downlink data block,
which system writes in channel data buffer successfully.

C70048
Definition

Number of data blocks sending according to given Abis bandwidth


Description

C70048 represents number of data blocks that will be send according


to given Abis bandwidth.
Measurement Point

C70048 increments when BRP service module successfully sends data


block which accords with maximum bearer capability of Abis bandwidth.

434 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

This counter helps to check the relationship between data block coding
scheme and bandwidth, as shown in Table 47.

TABLE 47 CORRESPONDENCE RELATIONSHIPS BETWEEN BANDWIDTH AND CODING


SCHEME

Abis bandwidth (Timeslot) Coding type


1 CS1, CS2, MCS1 and MCS2
2 CS3, CS4, MCS3, MCS4 and MCS5
3 MCS6
4 MCS7
5 MCS8 and MCS9

C70049
Definition

Total bytes of effective upper layer protocol data sent by packet


downlink channel
Description

C70049 represents number of signaling blocks sent by packet downlink


channel in cell.
Measurement Point

Number of bytes of LLC frame carried by the data block is added when
BSC successfully sends downlink data block.
Successful sending of downlink data block refers to downlink data block
that system writes to channel data buffer successfully.

C70050
Definition

Total bytes of effective upper layer protocol data received by packet


uplink channel
Description

C70050 represents total bytes of effective upper layer protocol data


received by packet uplink channel.
Measurement Point

C70050 increments when BSC successfully receives uplink data block.

C70051
Definition

Number of uplink GPRS TBF existing simultaneously in cell

Confidential and Proprietary Information of ZTE CORPORATION 435


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Description

C70051 represents Number of uplink GPRS TBF existing simultaneously


in cell.
Measurement Point

C70051 increments when BSC successfully establishes an uplink GPRS


TBF. Similarly, C70051 increments when BSC successfully releases an
uplink GPRS TBF.

C70052
Definition

Number of downlink GPRS TBF existing simultaneously in the cell


Description

C70052 represents Number of downlink GPRS TBF existing


simultaneously in cell
Measurement Point

C70052 increments when BSC successfully establishes downlink GPRS


TBF. Similarly, C70052 decrements when BSC successfully releases
downlink GPRS TBF.

C70053
Definition

Number of uplink EGPRS TBF existing simultaneously in cell


Description

C70053 represents Number of uplink EGPRS TBF existing


simultaneously in the cell.
Measurement Point

C70053 increments when BSC successfully establishes an uplink


EGPRS TBF. Similarly, C70053 decrements when BSC successfully
releases an uplink EGPRS TBF.

C70054
Definition

Number of downlink EGPRS TBF existing simultaneously in cell


Description

C70055 represents Number of downlink EGPRS TBF existing


simultaneously in cell.

436 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

Measurement Point

C70055 increments when BSC successfully establishes a downlink


EGPRS TBF. Similarly, C70055 decrements when BSC successfully
releases downlink EGPRS TBF.

C70055
Definition

Total number of establishments of GPRS uplink data TBF link


Description

C70055 represents total number of establishments of GPRS uplink data


TBF.
Measurement Point

C70055 increments when BSC successfully establishes an uplink GPRS


data TBF.

C70056
Definition

Total number of establishing GPRS uplink data TBF on PACCH


Description

C70056 represents number of establishing GPRS uplink data TBF on


PACCH.
Measurement Point

C70057 increments when BSC successfully establishes an uplink GPRS


data TBF.

C70057
Definition

Total number of GPRS downlink data TBF link establishments


Description

C70057 represents total number of GPRS downlink data TBF link


establishment.
Measurement Point

C70057 increments when BSC successfully establishes a downlink


GPRS data TBF.

C70058
Definition

Confidential and Proprietary Information of ZTE CORPORATION 437


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Total number of establishing GPRS downlink data TBF on PACCH


Description

C70058 represents total time of GPRS downlink data TBF link


establishment on PACCH.
Measurement Point

C70058 increments when BSC successfully establishes a downlink


GPRS data TBF.

C70059
Definition

Total number of bytes of LLC frame carried by GPRS uplink data TBF
Description

C70059 represents total number of bytes of LLC frame carried by GPRS


uplink data TBF.
Measurement Point

After uplink TBF normal release, BSC adds total number of bytes of LLC
frame that TBF transmits to the counter.

C70060
Definition

Total number of completion of GPRS uplink data TBF


Definition

C70060 represents total time of completion of GPRS uplink data TBF.


Measurement Point

C70060 increments when BSC normally releases an uplink data TBF.

C70061
Definition

Total duration of GPRS uplink data TBF


Description

C70061 represents total time of completion of GPRS uplink data TBF.


Measurement Point

C70062 records starting frame number when BSC successfully


establishes an uplink data TBF. Similarly, C70062 records ending frame
number when BSC normally releases an uplink data TBF. The
difference between starting frame number and ending frame number is

438 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

duration of TBF. This counter records the duration. Unit of duration is


block that is 20 ms.

C70062
Definition

Total number of bytes of LLC frame carried by GPRS downlink data TBF
Description

C70062 represents total number of bytes of LLC frame carried by GPRS


downlink data TBF.
Measurement Point

BRP performance measurement module adds counter variable of total


bytes number of LLC frame carried by GPRS downlink data TBF that
takes cell as unit. Shared memory of service module and performance
measurement module saves the variable. BSC adds the total bytes
number of LLC frame transmitted by TBF to the counter when a
downlink TBF releases normally.

C70063
Definition

Total time of completion of GPRS downlink data TBF


Description

C70063 represents total time of completion of GPRS uplink data TBF.


Measurement Point

C70063 increments when BSC normally releases a downlink data TBF.

C70064
Definition

Total duration of GPRS downlink data TBF


Description

C70064 represents total duration of GPRS downlink data TBF.


Measurement Point

C70064 records starting frame number when BSC successfully


establishes downlink data TBF. C70064 records the ending frame
number when BSC normally releases a downlink data TBF. The
difference between the starting frame number and ending frame
number is the duration of TBF. C70064 represents time, which is one
block time duration of 20ms.

Confidential and Proprietary Information of ZTE CORPORATION 439


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C70065
Definition

Total number of effective data blocks received by GPRS uplink TBF


Description

The counter represents number of effective data blocks received by


GPRS uplink TBF.
Measurement Point

The counter increments to one every time BSC receives an effective


data block.

C70066
Definition

Total number of NACK blocks received by GPRS uplink TBF


Description

C70066 represents number of NACK blocks received by GPRS uplink


TBF.
Measurement Point

When an uplink TBF normally ends, BSC adds the number of NACK
blocks received by the TBF to the counter.

C70067
Definition

Total number of effective data blocks that GPRS downlink TBF sends
Description

C70067 represents number of effective data blocks sent by GPRS


downlink TBF.
Measurement Point

When a downlink TBF normally ends, BSC adds number of effective


data blocks sent by TBF to the counter.
Effective number of data blocks refers to NACK blocks that is send first
time and retransmitted.

C70068
Definition
Total number of GPRS downlink TBF NACK blocks
Description

C70069 represents number of NACK blocks sent by GPRS uplink TBF

440 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

Measurement Point

When a downlink TBF normally ends, BSC adds number of NACK blocks
sent by TBF to the counter.

C70069
Definition

Total time of establishment of EGPRS uplink data TBF link


Definition

C70069 represents number of establishment of EGPRS uplink data TBF


link.
Measurement Point

C70069 increments when BSC successfully establishes a GPRS uplink


EGPRS data TBF.

C70070
Definition

Total time of establishing EGPRS uplink data TBF on PACCH


Description

C70070 represents total time of establishing EGPRS uplink data TBF on


PACCH.
Measurement Point

C70070 increments when BSC successfully establishes an uplink


EGPRS data TBF on PACCH.

C70071
Definition

Total time of EGPRS downlink data TBF link establishment


Description

C70071 represents total time of EGPRS downlink data TBF link


establishment.
Measurement Point

C70071 increments when BSC successfully establishes a downlink


EGPRS data TBF.

C70072
Definition

Total time of establishing EGPRS downlink data TBF on PACCH

Confidential and Proprietary Information of ZTE CORPORATION 441


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Description

C70072 represents total time of establishing EGPRS downlink data TBF


on PACCH.
Measurement Point

C70072 increments when BSC successfully establishes a downlink


EGPRS data TBF on PACCH.

C70073
Definition

Total bytes number of LLC frame carried by EGPRS uplink data TBF
Description

C70073 represents total bytes number of LLC frame carried by EGPRS


uplink data TBF.
Measurement Point

When an EGPRS uplink data TBF releases normally, BSC adds total
bytes number of LLC frame carried by TBF to the counter.

C70074
Definition

Total time of completion of EGPRS uplink data TBF


Description

C70074 represents total time of completion of EGPRS uplink data


TBF.
Measurement Point

C70074 increments when BSC normally releases an EGPRS uplink data


TBF.

C70075
Definition

Total duration of EGPRS uplink data TBF


Description

C70075 represents time of completion of EGPRS uplink data TBF.


Measurement Point

C70075 records starting frame number when RP service module


successfully establishes a downlink data TBF. Similarly, C70075
records ending frame number when BSC normally releases an EGPRS
uplink data TBF. The difference between starting frame number and

442 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

ending frame number is the duration of TBF. The duration adds to the
counter. Unit of duration is block that is 20 ms.

C70076
Definition

Total number of bytes of LLC frame carried by EGPRS downlink data


TBF
Description

C70076 represents total number of bytes of LLC frame carried by


EGPRS downlink data TBF.
Measurement Point

When an EGPRS downlink data releases normally, BSC adds the total
number of bytes of LLC frame transmitted by the TBF to the counter.

C70077
Definition

Total number of completion of EGPRS downlink data TBF


Description

C70077 represents total number of bytes of LLC frame carried by


EGPRS downlink data TBF.
Measurement Point

Definition

C70077 increments when BSC normally releases an EGPRS downlink


data.

C70078
Definition

Total duration of EGPRS downlink data TBF


Description

C70078 represents total duration of EGPRS downlink data TBF.


Measurement Point

C70078 records starting frame number when BSC successfully


establishes a downlink data TBF. C70078 records ending frame number
when BSC normally releases an EGPRS downlink data TBF. The
difference between starting frame number and ending frame number is
the duration of TBF. The duration adds to the counter. Unit of duration
is TDMA frame.

Confidential and Proprietary Information of ZTE CORPORATION 443


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C70079
Definition

Total number of effective data blocks received by EGPRS uplink TBF


Description

C70079 represents total number of effective data blocks received by


EGPRS uplink TBF.
Measurement Point

When an EGPRS uplink TBF ends normally, BSC adds the number of
effective data blocks received by the TBF to the counter.

C70080
Definition

Total number of NACK blocks received by EGPRS uplink TBF


Description

C70080 represents total number of NACK blocks received by EGPRS


uplink TBF.
Measurement Point

When an EGPRS uplink TBF ends normally, BSC adds number of


effective data blocks received by TBF to the counter.

C70081
Definition

Total number of effective data blocks sent by EGPRS downlink TBF


Description

C70081 represents total number of effective data blocks sent by


EGPRS downlink TBF
Measurement Point

When an EGPRS downlink TBF ends normally, BSC adds number of


effective data blocks sent by TBF to the counter.
Effective data blocks refer to NACK blocks sent first time and
retransmitted.

C70082
Definition

NACK blocks sent by EGPRS downlink TBF


Description

444 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

C70082 represents number of NACK blocks sent by EGPRS downlink


TBF.
Measurement Point

When an EGPRS downlink TBF ends normally, BSC adds number of


NACK data blocks sent by the TBF to the counter.

C70083
Definition

Total number of received downlink signaling LLC frame packets


Description

C70083 represents total number of received downlink signaling LLC


frame packets.
Measurement Point

C70083 increments when BSC receives a downlink signaling LLC frame.


The signaling LLC frame refers to T bit in a LLC frame when it is set to
zero.

C70084
Definition

Total number of discarded downlink signaling LLC frame packets


Description

C70084 represents total number of discarded downlink signaling LLC


frame packets.
Measurement Point

C70084 increments when BSC discards a downlink signaling LLC frame.


The signaling LLC frame refers to T bit in a LLC frame when it is set to
zero.

C70085
Definition

Total number of received LLC frame packets of downlink GPRS data


Description

C70085 represents total number of received LLC frame packets of


downlink GPRS data.
Measurement Point

C70086 increments when BSC receives a downlink GPRS signaling LLC


frame.

Confidential and Proprietary Information of ZTE CORPORATION 445


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

The signaling LLC frame refers to T bit in a LLC frame when it is set to
one.

C70086
Definition

Total number of discarded LLC frame packets of downlink GPRS data


Description

C70086 represents total number of discarded LLC frame packets of


downlink GPRS data.
Measurement Point

C70086 increments when BSC discards a downlink GPRS data LLC


frame.
The signaling LLC frame refers to T bit in a LLC frame when it is set to
one.

C70087
Definition

Total number of received LLC frame packets of downlink GPRS data


Description

C70087 represents total number of received LLC frame packets of


downlink GPRS data.
Measurement Point

When BSC receives a downlink EGPRS data LLC frame, The counter
increments one
The signaling LLC frame refers to T bit in a LLC frame when it is set to
one.

C70088
Definition

Total number of discarded LLC frame packets of downlink GPRS data


Description

C70088 represents total number of discarded LLC frame packets of


downlink GPRS data.
Measurement Point

C70088 increments when BSC discards a downlink EGPRS data LLC


frame.
The signaling LLC frame refers to T bit in a LLC frame when it is set to
one.

446 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

C70089
Definition

Time of stale GPRS uplink TBF receiving window


Description

The counter represents time of stale GPRS uplink TBF receiving window
Measurement Point

C70089 increments every time when there is a stale receiving window


on uplink GPRS TBF.
A stale receiving window refers to the difference between VR and VQ
that equals to the set window maximum value. The received data are
discarded due to its size exceeds the window range. FIGURE 37 shows
algorithm of uplink TBF receiving window.

FIGURE 37 - CALCULATING TIME OF STALE UPLINK GPRS TBF RECEIVING WINDOW

Start

Receiving effective
data block

Exceeding the window


range?

N
Y

(VR+WSIZE-VQ)
WSIZE=WSIZE? N

Y
Does the window stale
mark exist?

Y Y

The counter accumulates one

Set the window stale mark End

C70090
Definition

Confidential and Proprietary Information of ZTE CORPORATION 447


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Time of stale uplink EGPRS TBF receiving window


Description

C70090 represents time of stale uplink EGPRS TBF receiving window


Measurement Point

C70090 increments every time when there is a stale receiving window


on uplink EGPRS TBF.
A stale receiving window refers to the difference between VR and VQ
that equals to the set window maximum value. The received data are
discarded due to its size exceeds the window range.

C70091
Definition

Time of stale downlink GPRS TBF transmitting window


Description

C70091 represents time of stale downlink GPRS TBF transmitting


window
Measurement Point

C70091 increments every time when there is a stale receiving window


on downlink GPRS TBF.
A stale transmitting window refers to the difference between VS and
VA that equals to the set window maximum value. Only NACK block or
PENDING ACK block transmits. FIGURE 38 illustrates the algorithm.

448 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

FIGURE 38 - CALCULATING TIME OF STALE DOWNLINK GPRS TBF TRANSMITTING


WINDOW

Start

Transmitting NACK block or


PENDING ACK block

(VR+WSIZE-VQ)%
WSIZE=WSIZE? N

Y
Does the window stale
mark exist?

Y Y

The counter accumulates one

Set the window stale mark End

C70092
Definition

Time of stale downlink EGPRS TBF transmitting window


Description

C70092 represents time of stale downlink EGPRS TBF transmitting


window.
Measurement Point

C70092 increments every time when there is a stale transmitting


window on downlink EGPRS TBF.
A stale transmitting window refers to the difference between VS and
VA that equals to the set window maximum value. Only NACK block or
PENDING ACK block transmits.

C70093
Definition

Total number of abnormal release of uplink signaling TBF


Description

Confidential and Proprietary Information of ZTE CORPORATION 449


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C70093 represents total number of abnormal release of uplink


signaling TBF.
Measurement Point

C70094 increments when an uplink signaling TBF releases abnormally.


The signaling TBF is same as before. The abnormal release refers to
the releases except for all normal releases mentioned before.

C70094
Definition

Total number of abnormal release of uplink GPRS data TBF


Description

C70094 represents time of abnormal release of uplink GPRS data TBF.


Measurement Point

C70095 increments when an uplink data TBF releases abnormally.


GPRS data TBF defines as before. Abnormal release refers to the
releases except for all normal releases mentioned before.

C70095
Definition

Total number of abnormal release of uplink EGPRS data TBF


Description

C70095 represents number of abnormal release of uplink EGPRS data


TBF.
Measurement Point

C70095 increments when an uplink EGPRS data TBF releases


abnormally.
The EGPRS data TBF is same as before. The abnormal release refers to
the releases except for all normal releases mentioned before.

C70096
Definition

Total number of abnormal release of downlink signaling TBF


Description

C70096 represents total number of abnormal release of downlink


signaling TBF
Measurement Point

C70096 increments when an uplink signaling TBF releases abnormally.

450 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

The downlink signaling TBF is same as before. The abnormal release


refers to the releases except for all normally releases mentioned before.

C70097
Definition

Total number of abnormal release of downlink GPRS data TBF


Description

C70097 represents total number of abnormal release of downlink GPRS


data TBF.
Measurement Point

C70097 increments when a downlink data TBF releases abnormally.


The GPRS data TBF defines as before. The abnormal release refers to
the releases except for all normally releases mentioned before.

C70098
Definition

Total number of abnormal release of downlink EGPRS data TBF


Description

C70098 represents total number of abnormal release of downlink


EGPRS data TBF.
Measurement Point

C70098 increments when a downlink EGPRS data TBF releases


abnormally.
The EGPRS data TBF is same as before. The abnormal release refers to
the releases except for all normal releases mentioned before.

C70099
Definition

Number of requests for increasing Abis bandwidth by uplink TBF


Description

C70099 represents number of requests for increasing Abis bandwidth


by uplink TBF.
Measurement Point

C70099 increments when the uplink TBF requests to increase Abis


bandwidth.

Confidential and Proprietary Information of ZTE CORPORATION 451


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C70100
Definition

Number of requests for increasing Abis bandwidth by downlink TBF


Description

C70100 represents number of requests for increasing Abis bandwidth


by downlink TBF
Measurement Point

C70100 increments when the downlink TBF requests to increase Abis


bandwidth.
BSC requests to increase Abis bandwidth when the bandwidth is less
than requirement of coding scheme.

C70101
Definition

Number of handovers from GMSK modulation to 8PSK modulation


Description

C70101 represents number of handover from GMSK modulation to


8PSK modulation.
Measurement Point

C70101 increments every time when there is a handover from GMSK to


8PSK.

C70102
Definition

Number of handover from 8PSK modulation to GMSK modulation


Description

C70102 represents number of handover from 8PSK modulation to


GMSK modulation.
Measurement Point

C70102 increments every time when there is a handover 8PSK from to


GMSK.
Statistics of modulation handover include uplink/downlink TBF.

C70103
Definition

Number of handovers from CS1 and CS2 to CS3 and CS4


Description

452 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

C70104 represents number of handovers from CS1 and CS2 to CS3


and CS4.
Measurement Point

C70104 increments every time when there is a handover from CS1 and
CS2 to CS3 and CS4.
Statistics of modulation handover include uplink/downlink TBF.

C70104
Definition

Number of handovers from CS3, CS4 to CS1 and CS2


Description

C70104 represents number of handovers from CS3 and CS4 to CS1


and CS2.
Measurement Point

C70104 increments every time when there is a handover from CS3 and
CS4 to CS1and CS2.
Statistics of modulation handover include uplink/downlink TBF.

C70105
Definition

Total number of data packets sent to peripheral modules by BRP


Description

C70105 represents number of data packets send to peripheral modules


by BRP.
Measurement Point

C70105 increments every time when BRP successfully sends a data


packet to peripheral modules.
The successful sending refers to that BRP calls Ethernet communication
interface and the return value is normal.

C70106
Definition

Total number of data packets that BRP receives from peripheral


modules
Description

C70106 represents number of data packets that peripheral modules


send to BRP.
Measurement Point

Confidential and Proprietary Information of ZTE CORPORATION 453


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C70106 increments every time when BRP successfully receives a data


packet from peripheral modules.

C70107
Definition

Total number of data packets sent to BRP by peripheral modules


Description

C70107 represents number of data packets sent to BRP by peripheral


modules.
Measurement Point

C70107 increments every time when peripheral modules send a data


packet.

C70108
Definition

Total number of data packets received by peripheral modules that PCU


BRP sends
Description

C70108 represents number of data packets received by BRP that are


sent by peripheral modules
Measurement Point

C70108 increments when peripheral modules receive a data packet


from BRP.

C70109
Definition

Number of outgoing handover from cell


Description

C70109 represents number of outgoing handover from cell


Measurement Point

C70110 increments every time when there is an outgoing handover


from cell.

C70110
Definition

Number of incoming handover in cell


Description

454 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

C70110 represents number of incoming handover in cell


Measurement Point

C70110 increments every time when there is a mobile phone incoming


handover in cell.

C70111
Definition

Total number of CS1 data blocks received by packet uplink channel


Description

C70111 represents total number of CS1 data blocks received by packet


uplink channel.
Measurement Point

C7011 increments every time when BSC receives CS1 data block.

C70112
Definition

Total number of CS2 data blocks received by packet uplink channel


Description

C70112 represents total number of CS2 data blocks received by packet


uplink channel.
Measurement Point

C70112 increments every time when BSC receives CS2 data block.

C70113
Definition

Total number of CS3 data blocks received by packet uplink channel


Description

C70113 represents total number of CS3 data blocks received by packet


uplink channel.
Measurement Point

C70113 increments every time when BSC receives CS3 data block.

C70114
Definition

Total number of CS4 data blocks received by packet uplink channel


Description

Confidential and Proprietary Information of ZTE CORPORATION 455


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C70114 represents total number of CS4 data blocks received by packet


uplink channel.
Measurement Point

C70114 increments every time when BSC receives CS4 data block.

C70115
Definition

Total number of CS1 data blocks sent by packet downlink channel


Description

C70115 represents total number of CS1 data blocks sent by packet


downlink channel.
Measurement Point

C70115 increments every time when BSC sends CS1 data block.

C70116
Definition

Total number of CS2 data blocks sent by packet downlink channel


Description

C70116 represents total number of CS2 data blocks sent by packet


downlink channel.
Measurement Point

C70116 increments every time when BSC sends CS2 data block.

C70117
Definition

Total number of CS3 data blocks sent by packet downlink channel


Description

C70117 represents total number of CS3 data blocks sent by packet


downlink channel.
Measurement Point

C70117 increments every time when BSC sends CS3 data block.

C70118
Definition

Total number of CS4 data blocks sent by packet downlink channel


Description

456 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

C70118 represents total number of CS4 data blocks sent by packet


downlink channel.
Measurement Point

C70118 increments every time when BSC sends CS4 data block.

C70119
Definition

Minimum number of available PDCH


Description

C70119 represents minimum number of available PDCH


Measurement Point

C70119 records minimum number of available PDCH during the


measurement cycle (every fifteen minutes).

C70120
Definition

Total number of uplink blocks received by uplink channel (including


DUMMY block)
Description

C70120 represents total number of uplink blocks received by uplink


channel (including DUMMY block)
Measurement Point

C70120 increments when BSC receives block. When there is number


actual PS service, the DUMMY block records in the counter.

C70121
Definition

Total number of downlink blocks sent by downlink channel (including


DUMMY block)
Description

C70121 represents total number of downlink blocks sent by downlink


channel (including DUMMY block).
Measurement Point

C70121 increments when BSC sends block. When there is number


actual PS service, the DUMMY block records in the counter.
Table 48 shows the calculation and description of the Counters
C70501~C70536.

Confidential and Proprietary Information of ZTE CORPORATION 457


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

TABLE 48 COUNTERS C70501~C70536

Counter
Description Calculation instruction Remark
Number.
Two-digit-decimal
Success ratio of
(C70042+C70055+C70069)/ precision;
C70501 uplink TBF link
(C70040×100) percentage
establishment
representation
Two-digit-decimal
Success ratio of
(C70043+C70057+C70071)/ precision;
C70502 downlink TBF link
(C70041×100) percentage
establishment
representation
Two-digit-decimal
Percentage of uplink
C70042/(C70042+C70055+ precision;
C70503 signaling TBF in
C70069)×100 percentage
uplink TBF
representation
Two-digit-decimal
Percentage of
C70043/(C70043+C70057+ precision;
C70504 downlink signaling
C70071)×100 percentage
TBF in downlink TBF
representation
two-digit-decimal
Percentage of GPRS
precision,
C70505 uplink data TBF in C70055/(C70055+C70069)×100
percentage
uplink data TBF
representation
Percentage of GPRS two-digit-decimal
downlink data TBF precision,
C70506 C70057/(C70057+C70071)×100
in downlink data percentage
TBF representation
Counter
Description Calculation instruction Remark
Number.
two-digit-decimal
Percentage of uplink
precision,
C70507 packet channel RLC C70044/(C70044+C70045)×100
percentage
signaling overhead
representation
Percentage of two-digit-decimal
downlink packet precision,
C70508 C70046/(C70046+C70047)
channel RLC percentage
signaling overhead representation
two-digit-decimal
Uplink packet
precision,
C70509 channel utilization (C70044+C70045)/C70120×100
percentage
ratio
representation
two-digit-decimal
Downlink packet
(C70046+C700474)/C70121 × precision,
C70510 channel utilization
100 percentage
ratio
representation
two-digit-decimal
Abis bandwidth precision,
C70511 C70048/(C70046+C70047)×100
utilization ratio percentage
representation
Cell RLC layer uplink
C70512 C70050×8/(60×60)(bps) -
data throughput

458 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

Average RLC uplink


data throughput C70050×8/(60×60×C70019)
C70513 -
carried on each (bps)
channel
Cell RLC layer
C70514 downlink data C70049×8/(60×60)(bps) -
throughput
Average RLC
downlink data C70049×8/(60×60×C70019)
C70515 -
throughput carried (bps)
on each channel
Percentage of uplink two-digit-decimal
GPRS data TBF precision,
C70516 C70056/ C70055×100
established on percentage
PACCH representation
Percentage of two-digit-decimal
downlink GPRS data precision,
C70517 C70058/ C70057×100
TBF established on percentage
PACCH representation
Average rate of
C70059 × 1000 × 8/ ( C70061 ×
C70518 GPRS uplink data -
20)
TBF
Average rate of
C70062 × 1000 × 8/ ( C70064 ×
C70519 GPRS downlink data -
20)
TBF
two-digit-decimal
GPRS RLC uplink
precision,
C70520 block retransmission C70066/ C70065×100
percentage
ratio
representation
two-digit-decimal
GPRS RLC downlink
precision,
C70521 block retransmission C70068/ C70067×100
percentage
ratio
representation
Percentage of uplink two-digit-decimal
EGPRS data TBF precision,
C70522 C70070/ C70069×100
established on percentage
PACCH representation
Percentage of
two-digit-decimal
downlink EGPRS
precision,
C70523 data TBF C70072/ C70071×100
percentage
established on
representation
PACCH
Average rate of
C70073 × 1000 × 8/ ( C70075 ×
C70524 EGPRS uplink data -
20)
TBF (felt by user)
Average rate of
EGPRS downlink C70076 × 1000 × 8/ ( C70078 ×
C70525 -
data TBF (felt by 20)
user)

Confidential and Proprietary Information of ZTE CORPORATION 459


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

two-digit-decimal
EGPRS RLC uplink
precision,
C70526 block retransmission C70080/ C70079×100
percentage
ratio
representation
two-digit-decimal
EGPRS RLC
precision,
C70527 downlink block C70082/ C70081×100
percentage
retransmission ratio
representation
two-digit-decimal
Downlink LLC
precision,
C70528 signaling frame C70084/ C70083×100
percentage
discarding ratio
representation
two-digit-decimal
Downlink GPRS data
precision,
C70529 frame discarding C70086/ C70085×100
percentage
ratio
representation
two-digit-decimal
Downlink EGPRS
precision,
C70530 data frame C70088/ C70087×100
percentage
discarding ratio
representation
two-digit-decimal
Uplink signaling TBF precision,
C70531 C70093/ C70042×100
failure ratio percentage
representation
two-digit-decimal
Uplink GPRS data precision,
C70532 C70094/ C70055×100
TBF failure ratio percentage
representation
two-digit-decimal
Uplink EGPRS data precision,
C70533 C70095/ C70069×100
TBF failure ratio percentage
representation
two-digit-decimal
Downlink signaling precision,
C70534 C70096/ C70043×100
TBF failure ratio percentage
representation
two-digit-decimal
Downlink GPRS data precision,
C70535 C70097/ C70057×100
TBF failure ratio percentage
representation
two-digit-decimal
Downlink EGPRS
precision,
C70536 data TBF failure C70098/ C70071×100
percentage
ratio
representation

Following is specification for basic measurement based on BSC.

C90001
Definition

Total number of uplink data packets carried by BRCH

460 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

Description

C90001 represents total number of uplink data packets carried by


BRCH.
Measurement Point

C90001 increments when BSC sends the uplink block on BRCH.

C90002
Definition

Total number of downlink data packets carried by BRCH


Definition

C90001 represents total number of downlink data packets carried by


BRCH.
Measurement Point

C90002 increments when BSC receives the downlink block on BRCH.

C90003
Definition

Number of interruption due to BRCH receiving failure


Description

C90003 represents number of interruption due to BRCH receiving


failure.
Measurement Point

C90003 increments when there is data interruption due to BRCH


receiving failure.

C90004
Definition

Total number of data packets sent to FRP by BRP


Description

C90004 represents number of data packets send to FRP by BRP.


Measurement Point

C90004 increments when BRP successfully sends a data packet to FRP.

C90005
Definition

Total number of data packets received by BRP sent by FRP

Confidential and Proprietary Information of ZTE CORPORATION 461


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Description

C90005 represents number of data packets received by BRP that are


sent by FRP
Measurement Point

C90005 increments when BRP receives a data packet from FRP.

C90006
Definition

Total number of data packets sent to BRP by FRP


Description

C90006 represents number of data packets send to BRP by FRP


Measurement Point

C90006 increments when FRP successfully sends a data packet to BRP.

C90007
Definition

Total number of data packets received by FRP sent by BRP


Description

C90007 represents number of data packets received by FRP that are


sent by BRP
Measurement Point

C90007 increments when FRP receives a data packet from BRP.

PS Traffic Counters
PCU records the values of Traffic Statistic Counters and samples every five
minutes. The statistic unit of PS traffic statistic counters is cell. Table 49
shows the traffic statistic counters.

TABLE 49 TRAFFIC STATISTIC COUNTERS

Counter Number. Definition


C60001 Number of PPCH used
C60002 Total number of PRACH
C60003 Number of PAGCH used
C60004 Number of handover from CS1 to CS2
C60005 Number of handover from CS2 to CS1

462 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

Counter Number. Definition


C60006 Uplink power control
Number of attempt of increasing timeslot of dynamic Abis-
C60007
interface
Number of successful increasing timeslot of dynamic Abis-
C60008
interface
Number of attempt of decreasing timeslot of dynamic Abis-
C60009
interface
Number of successful decreasing timeslot of dynamic Abis-
C60010
interface
Total number of CS1 data blocks received by packet uplink
C60011
channel
Total number of CS2 data blocks received by packet uplink
C60012
channel
Total number of CS3 data blocks received by packet uplink
C60013
channel
Total number of CS4 data blocks received by packet uplink
C60014
channel
Total number of MCS1 data blocks received by packet uplink
C60015
channel
Total number of MCS2 data blocks received by packet uplink
C60016
channel
Total number of MCS3 data blocks received by packet uplink
C60017
channel
Total number of MCS4 data blocks received by packet uplink
C60018
channel
Total number of MCS5 data blocks received by packet uplink
C60019
channel
Total number of MCS6 data blocks received by packet uplink
C60020
channel
Total number of MCS7 data blocks received by packet uplink
C60021
channel
Total number of MCS8 data blocks received by packet uplink
C60022
channel
Total number of MCS9 data blocks received by packet uplink
C60023
channel
Total number of CS1 data blocks received by packet downlink
C60024
channel
Total number of CS2 data blocks received by packet downlink
C60025
channel
Total number of CS3 data blocks received by packet downlink
C60026
channel
Total number of CS4 data blocks received by packet downlink
C60027
channel
Total number of MCS1 data blocks received by packet
C60028
downlink channel

Confidential and Proprietary Information of ZTE CORPORATION 463


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Counter Number. Definition


Total number of MCS2 data blocks received by packet
C60029
downlink channel
Total number of MCS3 data blocks received by packet
C60030
downlink channel
Total number of MCS4 data blocks received by packet
C60031
downlink channel
Total number of MCS5 data blocks received by packet
C60032
downlink channel
Total number of MCS6 data blocks received by packet
C60033
downlink channel
Total number of MCS7 data blocks received by packet
C60034
downlink channel
Total number of MCS8 data blocks received by packet
C60035
downlink channel
Total number of MCS9 data blocks received by packet
C60036
downlink channel
Total number of NACK blocks with CS1 coding scheme in
C60037
GPRS uplink TBF
Total number of NACK blocks with CS2 coding scheme in
C60038
GPRS uplink TBF
Total number of NACK blocks with CS3 coding scheme in
C60039
GPRS uplink TBF
Total number of NACK blocks with CS4 coding scheme in
C60040
GPRS uplink TBF
Total number of NACK blocks with CS1 coding scheme in
C60041
GPRS downlink TBF
Total number of NACK blocks with CS2 coding scheme in
C60042
GPRS uplink TBF
Total number of NACK blocks with CS3 coding scheme in
C60043
GPRS uplink TBF
Total number of NACK blocks with CS4 coding scheme in
C60044
GPRS uplink TBF
Total number of NACK blocks with MCS1 coding scheme in
C60045
EGPRS uplink TBF
Total number of NACK blocks with MCS2 coding scheme in
C60046
EGPRS uplink TBF
Total number of NACK blocks with MCS3 coding scheme in
C60047
EGPRS uplink TBF
Total number of NACK blocks with MCS4 coding scheme in
C60048
EGPRS uplink TBF
Total number of NACK blocks with MCS5 coding scheme in
C60049
EGPRS uplink TBF
Total number of NACK blocks with MCS6 coding scheme in
C60050
EGPRS uplink TBF
Total number of NACK blocks with MCS7 coding scheme in
C60051
EGPRS uplink TBF

464 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

Counter Number. Definition


Total number of NACK blocks with MCS8 coding scheme in
C60052
EGPRS uplink TBF
Total number of NACK blocks with MCS9 coding scheme in
C60053
EGPRS uplink TBF
Total number of NACK blocks with MCS1 coding scheme in
C60054
EGPRS downlink TBF
Total number of NACK blocks with MCS2 coding scheme in
C60055
EGPRS downlink TBF
Total number of NACK blocks with MCS3 coding scheme in
C60056
EGPRS downlink TBF
Total number of NACK blocks with MCS4 coding scheme in
C60057
EGPRS downlink TBF
Total number of NACK blocks with MCS5 coding scheme in
C60058
EGPRS downlink TBF
Total number of NACK blocks with MCS6 coding scheme in
C60059
EGPRS downlink TBF
Total number of NACK blocks with MCS7 coding scheme in
C60060
EGPRS downlink TBF
Total number of NACK blocks with MCS8 coding scheme in
C60061
EGPRS downlink TBF
Total number of NACK blocks with MCS9 coding scheme in
C60062
EGPRS downlink TBF
C60063 Value of N3101 counter
C60064 Value of N3105 counter
Number of abnormal releases of uplink TBF due to not
C60065
receiving resource request
Number of abnormal releases of uplink signaling TBF due to
C60066
N3101 overflow
Number of abnormal releases of uplink signaling TBF due to
C60067
N3103 overflow
C60068 Number of forced releases of uplink signaling TBF
Number of abnormal releases of uplink signaling TBF due to
C60069
dead suspending of the instance
Number of abnormal releases of uplink signaling TBF due to
C60070
internal error
Number of abnormal releases of uplink GPRS TBF due to
C60071
N3101 overflow
Number of abnormal releases of uplink GPRS TBF due to
C60072
N3103 overflow
C60073 Number of forced releases of uplink GPRS TBF
Number of abnormal releases of uplink GPRS TBF due to dead
C60074
suspending of the instance
Number of abnormal releases of uplink GPRS TBF due to
C60075
internal error

Confidential and Proprietary Information of ZTE CORPORATION 465


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Counter Number. Definition


Number of abnormal releases of uplink EGPRS TBF due to
C60076
N3101 overflow
Number of abnormal releases of uplink EGPRS TBF due to
C60077
N3103 overflow
C60078 Number of forced releases of uplink EGPRS TBF
Number of abnormal releases of uplink EGPRS TBF due to
C60079
dead suspending of the instance
Number of abnormal releases of uplink GPRS TBF due to
C60080
internal error
Number of abnormal releases of downlink signaling TBF due
C60081
to POLL overflow
Number of abnormal releases of downlink signaling TBF due
C60082
to N3105 overflow
C60083 Number of forced releases of downlink signaling TBF
Number of abnormal releases of downlink signaling TBF due
C60084
to dead suspending of the instance
Number of abnormal releases of downlink signaling TBF due
C60085
to internal error
Number of abnormal releases of downlink GPRS data TBF due
C60086
to POLL overflow
Number of abnormal releases of downlink GPRS data TBF due
C60087
to N3105 overflow
C60088 Number of forced releases of downlink GPRS data TBF
Number of abnormal releases of downlink GPRS data TBF due
C60089
to dead suspending of the instance
Number of abnormal releases of downlink GPRS data TBF due
C60090
to internal error
Number of abnormal releases of downlink EGPRS data TBF
C60091
due to POLL overflow
Number of abnormal releases of downlink EGPRS data TBF
C60092
due to N3105 overflow
C60093 Number of forced releases of downlink EGPRS data TBF
Number of abnormal releases of downlink EGPRS data TBF
C60094
due to dead suspending of the instance
Number of abnormal releases of downlink GPRS data TBF due
C60095
to internal error

PS Traffic Counters Explanation


C60001
Definition

Number of PPCH used

466 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

Description

C60001 represents number of PPCH currently in use during the statistic


period.
Measurement Point

C60001 increments every time when BSC uses PPCH to send paging
message or BSC sends downlink assignment.

C60002
Definition

Total number of PRACH


Description

C60002 represents number of PRACH currently in use during the


statistic period.
Measurement Point

C60002 increments every time when BSC receives the uplink channel
request send on PRACHJ

C60003
Definition

Number of PAGCH used


Description

C60003 represents number of PAGCH, currently in use during the


statistic period.
Measurement Point

C60003 increments every time when BSC uses PAGCH to send the
uplink assignment message.

C60004
Definition

Number of handover from CS1 to CS2


Description

C60005 represents number of TBF coding scheme’s handover from CS1


to CS2.
Measurement Point

C60005 increments every time when BSC initiates a coding scheme


handover from CS1 to CS2 according to current channel status and
wireless environment.

Confidential and Proprietary Information of ZTE CORPORATION 467


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C60005
Number of handover from CS2 to CS1
Description

C60005 represents number of TBF coding scheme’s handover from CS2


to CS1.
Measurement Point

C60005 increments every time when BSC initiates a coding scheme


handover from CS2 to CS1 according to current channel status and
wireless environment.

C60006
Definition

Uplink power control


Description

C60006 represents number of uplink power control of the mobile


phone by BSC in the uplink TBF procedure.
Measurement Point

C60006 increments every time when BSC initiates an uplink power


control according to current channel status.

C60007
Definition

Number of attempt to increase timeslot of dynamic Abis-interface


Description

C60007 represents number of attempt to increase timeslot of dynamic


Abis-interface.
Measurement Point

C60007 increments every time when BRP service module on PCU


initiates an increasing of dynamic Abis-interface.

C60008
Definition

Number of successful increasing timeslot of dynamic Abis-interface


Description

C6008 represents number of successful increasing timeslot of dynamic


Abis communication link.
Measurement Point

468 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

C60008 increments every time when BRP service module on PCU


successfully initiates an increasing of dynamic Abis-interface.

C60009
Definition

Number of attempt of decreasing timeslot of dynamic Abis-interface


Description

C60009 represents number of attempt of increasing timeslot of


dynamic Abis communication link.
Measurement Point

C60009 increments every time when BRP service module on PCU


initiates a decreasing of dynamic Abis-interface.

C60010
Definition

Number of successful decreasing timeslot of dynamic Abis-interface


Description

C60010 represents number of successful decreasing timeslot of


dynamic Abis communication link.
Measurement Point

C60010 increments every time when BRP service module on PCU


successfully initiates a decreasing of dynamic Abis-interface.

C60011
Definition

Total number of CS1 data blocks received by packet uplink channel


Description

C60011 represents number of CS1 data blocks received by packet


uplink channel.
Measurement Point

C60011 increments every time when BSC receives an effective CS1


data block.
The effective data block refers to data block that combines into LLC
frame.

C60012
Definition

Total number of CS2 data blocks received by packet uplink channel

Confidential and Proprietary Information of ZTE CORPORATION 469


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Description

C60012 represents number of CS2 data blocks received by packet


uplink channel.
Measurement Point

C60012 increments every time when BSC receives an effective CS2


data block.

C60013
Definition

Total number of CS3 data blocks received by packet uplink channel


Description

C60013 represents number of CS3 data blocks received by packet


uplink channel.
Measurement Point

C60013 increments every time when BSC receives an effective CS3


data block.

C60014
Definition

Total number of CS4 data blocks received by packet uplink channel


Description

C60014 represents number of CS4 data blocks received by packet


uplink channel.
Measurement Point
C60014 increments every time when BSC receives an effective CS4
data block.

C60015
Definition

Total number of MCS1 data blocks received by packet uplink channel


Description

C60015 represents number of MCS1 data blocks received by packet


uplink channel.
Measurement Point

C60015 increments every time when BSC receives an effective MCS1


data block.

470 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

C60016
Definition

Total number of MCS2 data blocks received by packet uplink channel


Description

C60016 represents number of MCS2 data blocks received by packet


uplink channel.
Measurement Point

C60016 increments every time when BSC receives an effective MCS2


data block.

C60017
Definition

Total number of MCS3 data blocks received by packet uplink channel


Description

C6007 represents number of MCS3 data blocks received by packet


uplink channel.
Measurement Point

C60017 increments every time when BSC receives an effective MCS3


data block.

C60018
Definition

Total number of MCS4 data blocks received by packet uplink channel


Description

C60018 represents number of MCS4 data blocks received by packet


uplink channel.
Measurement Point

C60018 increments every time when BSC receives an effective MCS4


data block.

C60019
Definition

Total number of MCS5 data blocks received by packet uplink channel


Definition

C60019 represents number of MCS5 data blocks received by packet


uplink channel.

Confidential and Proprietary Information of ZTE CORPORATION 471


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Measurement Point

C60019 increments every time when BSC receives an effective MCS5


data block, The counter increments one.

C60020
Definition

Total number of MCS6 data blocks received by packet uplink channel


Definition

C60020 represents number of MCS6 data blocks received by packet


uplink channel.
Measurement Point

C60020 increments every time when BSC receives an effective MCS6


data block.

C60021
Definition

Total number of MCS7 data blocks received by packet uplink channel


Description

C60021 represents number of MCS7 data blocks received by packet


uplink channel.
Measurement Point

C60021 increments every time when BSC receives an effective MCS7


data block.

C60022
Definition

Total number of MCS8 data blocks received by packet uplink channel


Description

C60022 represents number of MCS8 data blocks received by packet


uplink channel.
Measurement Point

C60022 increments every time when BSC receives an effective MCS8


data block.

C60023
Definition

Total number of MCS9 data blocks received by packet uplink channel

472 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

Description

C60023 represents number of MCS9 data blocks received by packet


uplink channel.
Measurement Point

C60023 increments every time when BSC receives an effective MCS9


data block.

C60024
Definition

Total number of CS1 data blocks sent by packet downlink channel


Definition

C60024 represents number of CS1 data blocks sent by packet downlink


channel.
Measurement Point

C60024 increments every time when BSC sends an effective CS1 data
block, the counter increments one.
The effective data block refers to data block, which system writes
successfully to channel data buffer.

C60025
Definition

Total number of CS2 data blocks sent by packet downlink channel


Description

C60025 represents number of CS2 data blocks sent by packet downlink


channel.
Measurement Point

C60025 increments every time when BSC sends an effective CS2 data
block.

C60026
Definition

Total number of CS3 data blocks sent by packet downlink channel


Description

C60026 represents number of CS3 data blocks sent by packet downlink


channel.
Measurement Point

Confidential and Proprietary Information of ZTE CORPORATION 473


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C60026 increments every time when BSC sends an effective CS3 data
block.

C60027
Definition

Total number of CS4 data blocks sent by packet downlink channel


Description

C60027 represents number of CS4 data blocks sent by packet downlink


channel.
Measurement Point

C60027 increments every time when BSC sends an effective CS4 data
block.

C60028
Definition

Total number of MCS1 data blocks sent by packet downlink channel


Definition

C60028 represents number of MCS1 data blocks sent by packet


downlink channel.
Measurement Point

C60028 increments every time when BSC sends an effective MCS1


data block.

C60029
Definition

Total number of MCS2 data blocks sent by packet downlink channel


Description

C60029 represents number of MCS2 data blocks sent by packet


downlink channel.
Measurement Point

C60029 increments every time when BSC sends an effective MCS2


data block.

C60030
Definition

Total number of MCS3 data blocks sent by packet downlink channel


Description

474 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

C60030 represents number of MCS3 data blocks sent by packet


downlink channel.
Measurement Point

C60030 increments every time when BSC sends an effective MCS3


data block.

C60031
Definition

Total number of MCS4 data blocks sent by packet downlink channel


Description

C60031 represents number of MCS4 data blocks sent by packet


downlink channel.
Measurement Point

C60031 increments every time when BSC sends an effective MCS4


data block.

C60032
Definition

Total number of MCS5 data blocks sent by packet downlink channel


Description

C60032 represents number of MCS5 data blocks sent by packet


downlink channel.
Measurement Point

C60032 increments every time when BSC sends an effective MCS5


data block.

C60033
Definition

Total number of MCS6 data blocks sent by packet downlink channel


Description

C60033 represents number of MCS6 data blocks sent by packet


downlink channel.
Measurement Point

C60033 increments every time when BSC sends an effective MCS6


data block.

C60034
Definition

Confidential and Proprietary Information of ZTE CORPORATION 475


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Total number of MCS7 data blocks sent by packet downlink channel


Description

C60034 represents number of MCS7 data blocks sent by packet


downlink channel.
Measurement Point

C60034 increments every time when BSC sends an effective MCS7


data block.

C60035
Definition

Total number of MCS8 data blocks sent by packet downlink channel


Description

C60035 represents number of MCS8 data blocks sent by packet


downlink channel.
Measurement Point

C60035 increments every time when BSC sends an effective MCS8


data block.

C60036
Definition

Total number of MCS9 data blocks sent by packet downlink channel


Description

C60036 represents number of MCS9 data blocks sent by packet


downlink channel.
Measurement Point

C60036 increments every time when BSC sends an effective MCS9


data block.

C60037
Definition

Total number of NACK blocks with CS1 coding scheme in GPRS uplink
TBF
Description

C60037 represents number of CS1 NACK blocks received by GPRS


uplink TBF.

476 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

Measurement Point

When a GPRS uplink TBF normally ends, BSC adds the number of CS1
NACK data blocks received by TBF to C60037.
The NACK data block refers to a data block that locates between VQ
and VR and combines into LLC frame (including VQ).

C60038
Definition

Total number of NACK blocks with CS2 coding scheme in GPRS uplink
TBF
Description

C60038 represents number of CS2 NACK blocks received by GPRS


uplink TBF.
Measurement Point

When a GPRS uplink TBF normally ends, BSC adds the number of CS2
NACK data blocks received by TBF to counter.

C60039
Definition

Total number of NACK blocks with CS3 coding scheme in GPRS uplink
TBF
Description

C60039 represents number of CS3 NACK blocks received by GPRS


uplink TBF.
Measurement Point

When a GPRS uplink TBF normally ends, BSC adds the number of CS3
NACK data blocks received by TBF to C60039.

C60040
Definition

Total number of NACK blocks with CS4 coding scheme in GPRS uplink
TBF
Description

C60040 represents number of CS4 NACK blocks received by GPRS


uplink TBF.
Measurement Point

When a GPRS uplink TBF normally ends, BSC adds the number of CS4
NACK data blocks received by the TBF to the counter.

Confidential and Proprietary Information of ZTE CORPORATION 477


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C60041
Definition

Total number of NACK blocks with CS1 coding scheme in GPRS


downlink TBF
Description

C60041 represents number of CS1 NACK blocks received by GPRS


downlink TBF.
Measurement Point

When a GPRS downlink TBF normally ends, BSC adds the number of
CS1 NACK data blocks sent by the TBF t C60041.

C60042
Definition

Total number of NACK blocks with CS2 coding scheme in GPRS


downlink TBF
Description

C60042 represents number of CS2 NACK blocks received by GPRS


downlink TBF.
Measurement Point

When a GPRS downlink TBF normally ends, BSC will add the number of
CS2 NACK data blocks sent by TBF to C60042.

C60043
Definition

Total number of NACK blocks with CS3 coding scheme in GPRS


downlink TBF
Description

C60043 represents number of CS3 NACK blocks received by GPRS


downlink TBF.
Measurement Point

When a GPRS downlink TBF normally ends, BSC will adds the number
of CS3 NACK data blocks sent by TBF to C60043.

C60044
Definition

Total number of NACK blocks with CS4 coding scheme in GPRS


downlink TBF
Description

478 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

C60044 represents number of CS4 NACK blocks received by GPRS


downlink TBF.
Measurement Point

When a GPRS downlink TBF normally ends, BSC adds the number of
CS4 NACK data blocks sent by TBF to C60044.

C60045
Definition

Total number of MCS1 NACK blocks received by EGPRS uplink TBF


Description

C60045 represents number of MCS1 NACK blocks received by EGPRS


uplink TBF.
Measurement Point

When EGPRS uplink TBF normally ends, BSC adds the value number of
MCS1 NACK data blocks received by TBF to C60045
Coding scheme belonging to MSC1 NACK data block refers to data
block, which has SPB not equal to 0x01 or 0x10 and locates between
VQ and VR. It combines into LLC frame (including VQ).

C60046
Definition

Total number of MCS2 NACK blocks received by EGPRS uplink TBF


Description

C60046 represents number of MCS2 NACK blocks received by EGPRS


uplink TBF.
Measurement Point

When EGPRS uplink TBF normally ends, BSC adds the number of MCS2
NACK data blocks received by TBF to C60046.
Coding scheme belonging to MSC2 NACK data block refers to data
block, which has SPB not equal to 0x01 or 0x10 and locates between
VQ and VR. It combines into LLC frame (including VQ).

C60047
Definition

Total number of MCS3 NACK blocks received by EGPRS uplink TBF


Description

C60047 represents number of MCS3 NACK blocks received by EGPRS


uplink TBF.
Measurement Point

Confidential and Proprietary Information of ZTE CORPORATION 479


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

When an EGPRS uplink TBF normally ends, BSC adds the number of
MCS3 NACK data blocks received by TBF to C60047.
Coding scheme belonging to MSC3 NACK data block refers to data
block, which has SPB not equal to 0x01 or 0x10 and locates between
VQ and VR. It combines into LLC frame (including VQ).

C60048
Definition

Total number of MCS4 NACK blocks received by EGPRS uplink TBF


Description

C60048 represents number of MCS4 NACK blocks received by EGPRS


uplink TBF.
Measurement Point

When an EGPRS uplink TBF normally ends, BSC adds the number of
MCS4 NACK data blocks received by the TBF to C60048.
Coding scheme belonging to MSC4 NACK data block refers to data
block, which has SPB not equal to 0x01 or 0x10 and locates between
VQ and VR. It combines into LLC frame (including VQ).

C60049
Definition

Total number of MCS5 NACK blocks received by EGPRS uplink TBF


Description

C60049 represents number of MCS5 NACK blocks received by EGPRS


uplink TBF.
Measurement Point

When an EGPRS uplink TBF normally ends, BSC adds the number of
MCS5 NACK data blocks received by TBF to C60049.
Coding scheme belonging to MSC5 NACK data block refers to data
block, which has SPB not equal to 0x01 or 0x10 and locates between
VQ and VR. It combines into LLC frame (including VQ).

C60050
Definition

Total number of MCS6 NACK blocks received by EGPRS uplink TBF


Description

C60050 represents number of MCS6 NACK blocks received by EGPRS


uplink TBF.
Measurement Point

480 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

When an EGPRS uplink TBF normally ends, BSC will add the number of
MCS6 NACK data blocks received by TBF to C60050.
Coding scheme belonging to MSC6 NACK data block refers to data
block, which has SPB not equal to 0x01 or 0x10 and locates between
VQ and VR. It combines into LLC frame (including VQ).

C60051
Definition

Total number of MCS7 NACK blocks received by EGPRS uplink TBF


Description

C60051 represents number of MCS7 NACK blocks received by EGPRS


uplink TBF.
Measurement Point

When an EGPRS uplink TBF normally ends, BSC adds the number of
MCS7 NACK data blocks received by TBF to C60051.
Coding scheme belonging to MSC7 NACK data block refers to data
block, which has SPB not equal to 0x01 or 0x10 and locates between
VQ and VR. It combines into LLC frame (including VQ).

C60052
Definition

Total number of MCS8 NACK blocks received by EGPRS uplink TBF


Description

C60052 represents number of MCS8 NACK blocks received by EGPRS


uplink TBF.
Measurement Point

When an EGPRS uplink TBF normally ends, BSC will add the number of
MCS8 NACK data blocks received by the TBF to C60052.
Coding scheme belonging to MSC8 NACK data block refers to data
block, which has SPB not equal to 0x01 or 0x10 and locates between
VQ and VR. It combines into LLC frame (including VQ).

C60053
Definition

Total number of MCS9 NACK blocks received by EGPRS uplink TBF


Description

C60053 represents number of MCS9 NACK blocks received by EGPRS


uplink TBF.
Measurement Point

Confidential and Proprietary Information of ZTE CORPORATION 481


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

When an EGPRS uplink TBF normally ends, BSC adds the number of
MCS9 NACK data blocks received by TBF to C60053.
Coding scheme belonging to MSC9 NACK data block refers to data
block, which has SPB not equal to 0x01 or 0x10 and locates between
VQ and VR. It combines into LLC frame (including VQ).

C60054
Total number of NACK blocks with MCS1 coding scheme in EGPRS
downlink TBF
Description

C60054 represents number of MCS8 NACK blocks received by EGPRS


downlink TBF.
Measurement Point

When an EGPRS downlink TBF normally ends, BSC adds the number of
MCS1 NACK data blocks sent by the TBF to C60055.

C60055
Definition

Total number of NACK blocks with MCS2 coding scheme in EGPRS


downlink TBF
Description

C60055 represents number of MCS2 NACK blocks received by EGPRS


downlink TBF.
Measurement Point

When an EGPRS downlink TBF normally ends, BSC adds the number of
MCS2 NACK data blocks sent by the TBF to C60055.

C60056
Definition

Total number of NACK blocks with MCS3 coding scheme in EGPRS


downlink TBF
Description

C60056 represents number of MCS3 NACK blocks received by EGPRS


downlink TBF.
Measurement Point

When an EGPRS downlink TBF normally ends, BSC adds the number of
MCS3 NACK data blocks sent by TBF to C60056.

482 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

C60057
Definition

Total number of NACK blocks with MCS4 coding scheme in EGPRS


downlink TBF
Description

C60057 represents number of MCS4 NACK blocks received by EGPRS


downlink TBF.
Measurement Point

When an EGPRS downlink TBF normally ends, BSC adds the number of
MCS4 NACK data blocks sent by TBF to C60057.

C60058
Definition

Total number of NACK blocks with MCS5 coding scheme in EGPRS


downlink TBF
Description

C60058 represents number of MCS5 NACK blocks received by EGPRS


downlink TBF.
Measurement Point

When an EGPRS downlink TBF normally ends, BSC adds the number of
MCS5 NACK data blocks sent by TBF to. C60058

C60059
Definition

Total number of NACK blocks with MCS6 coding scheme in EGPRS


downlink TBF
Description

C60059 represents number of MCS6 NACK blocks received by EGPRS


downlink TBF.
Measurement Point

When an EGPRS downlink TBF normally ends, BSC adds the number of
MCS6 NACK data blocks sent by TBF to C60059.

C60060
Definition

Total number of NACK blocks with MCS7 coding scheme in EGPRS


downlink TBF
Description

Confidential and Proprietary Information of ZTE CORPORATION 483


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C60060 represents number of MCS7 NACK blocks received by EGPRS


downlink TBF.
Measurement Point

When an EGPRS downlink TBF normally ends, BSC adds the number of
MCS7 NACK data blocks sent by TBF to C60060.

C60061
Definition

Total number of NACK blocks with MCS8 coding scheme in EGPRS


downlink TBF
Description

C60061 represents number of MCS8 NACK blocks received by EGPRS


downlink TBF.
Measurement Point

When an EGPRS downlink TBF normally ends, BSC adds the number of
MCS8 NACK data blocks sent by TBF to C60060.

C60062
Definition

Total number of NACK blocks with MCS9 coding scheme in EGPRS


downlink TBF
Description

C60062 represents number of MCS9 NACK blocks received by EGPRS


downlink TBF.
Measurement Point

When an EGPRS downlink TBF normally ends, BSC adds the number of
MCS9 NACK data blocks sent by TBF to C60062.

C60063
Definition

Value of N3101 counter


Description

C60063 represents value of N3101 counter.


Measurement Point

When N3101 clears to zero, BSC adds the value of N3101 to C60063.

C60064
Definition

484 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

Value of N3105 counter


Description

C60064 represents value of N3105 counter.


Measurement Point

When N3105 clears to zero, BSC adds the value of N3105 to C60064.

C60065
Definition

Number of abnormal releases of uplink TBF due to not receiving


resource request
Description

C60065 represents number of abnormal releases of uplink TBF due to


not receiving resource request.
Measurement Point

C60065 increments when BSC des not receive resource request on the
block that should receive resource request.

C60066
Definition

Number of abnormal releases of uplink signaling TBF due to N3101


overflow
Description

C60066 represents number of abnormal releases of uplink signaling


TBF due to N3101 overflow.
Measurement Point

C60066 increments when uplink-signaling TBF releases abnormally due


to N3101 overflow.

C60067
Definition

Number of abnormal releases of uplink signaling TBF due to N3103


overflow
Description

C60067 represents number of abnormal releases of uplink signaling


TBF due to N3103 overflow.
Measurement Point

Confidential and Proprietary Information of ZTE CORPORATION 485


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C60067 increments when uplink-signaling TBF releases abnormally due


to N3103 overflow.

C60068
Definition

Number of abnormal releases of uplink signaling TBF due to forced


release
Description

C60068 represents number of abnormal releases of uplink signaling


TBF due to forced release.
Measurement Point

C60065 increments when BSC abnormally releases the uplink signaling


TBF due to receiving the forced release message.

C60069
Definition

Number of abnormal releases of uplink signaling TBF due to dead


suspending of the instance
Description

C60069 represents number of abnormal releases of uplink signaling


TBF due to dead suspending of the instance.
Measurement Point

C60069 increments when BSC abnormally releases the uplink signaling


TBF due to dead suspending of the instance.

C60070
Definition

Number of abnormal releases of uplink signaling TBF due to internal


error
Description

C60070 represents number of abnormal releases of uplink signaling


TBF due to internal error.
Measurement Point

C60070 increments when BSC abnormally releases the uplink signaling


TBF due to internal error.

C60071
Definition

486 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

Number of abnormal releases of uplink GPRS data TBF due to N3101


overflow
Description

C60071 represents number of abnormal releases of uplink GPRS data


TBF due to N3101 overflow.
Measurement Point

C60071 increments when BSC abnormally releases the uplink GPRS


data TBF due to N3101 overflow.

C60072
Definition

Number of abnormal releases of uplink GPRS data TBF due to N3103


overflow
Description

C60072 represents number of abnormal releases of uplink GPRS data


TBF due to N3103 overflow.
Measurement Point

C60072 increments when BSC abnormally releases the uplink GPRS


data TBF due to N3103 overflow.

C60073
Definition

Number of abnormal releases of uplink GPRS data TBF due to forced


release
Description

C60073 represents number of abnormal releases of uplink GPRS data


TBF due to forced release.
Measurement Point

C60073 increments when BSC abnormally releases the uplink GPRS


data TBF due to receiving the forced release message.

C60074
Definition

Number of abnormal releases of uplink GPRS data TBF due to dead


suspending of the instance
Description

C60074 represents number of abnormal releases of uplink GPRS data


TBF due to dead suspending of the instance.

Confidential and Proprietary Information of ZTE CORPORATION 487


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Measurement Point

C60074 increments when BSC abnormally releases the uplink GPRS


data TBF due to dead suspending of the instance.

C60075
Definition

Number of abnormal releases of uplink GPRS data TBF due to internal


error
Description

C60075 represents number of abnormal releases of uplink GPRS data


TBF due to internal error.
Measurement Point

C60075 increments when BSC abnormally releases the uplink GPRS


data TBF due to internal error.

C60076
Definition

Number of abnormal releases of uplink EGPRS data TBF due to N3101


overflow
Description

C60076 represents number of abnormal releases of uplink EGPRS data


TBF due to N3101 overflow.
Measurement Point

C60076 increments when BSC abnormally releases the uplink EGPRS


data TBF due to N3101 overflow.

C60077
Definition

Number of abnormal releases of uplink EGPRS data TBF due to N3103


overflow
Description

C60077 represents number of abnormal releases of uplink EGPRS data


TBF due to N3103 overflow.
Measurement Point

C60077 increments when BSC abnormally releases the uplink EGPRS


data TBF due to N3103 overflow.

488 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

C60078
Definition

Number of abnormal releases of uplink EGPRS data TBF due to forced


release
Description

C60078 represents number of abnormal releases of uplink EGPRS data


TBF due to forced release.
Measurement Point

C60078 increments when BSC abnormally releases the uplink EGPRS


data TBF due to forced release.

C60079
Definition

Number of abnormal release of uplink EGPRS data TBF due to dead


suspending of the instance
Description

C60079 represents number of abnormal releases of uplink EGPRS data


TBF due to dead suspending of the instance.
Measurement Point

C60079 increments when BSC abnormally releases the uplink EGPRS


data TBF due to dead suspending of the instance.

C60080
Definition

Number of abnormal releases of uplink EGPRS data TBF due to internal


error
Description

C60080 represents number of abnormal releases of uplink EGPRS data


TBF due to internal error.
Measurement Point

C60080 increments when BSC abnormally releases the uplink EGPRS


data TBF due to internal error.
The internal error refers to abnormal release case except for those
such as forced release, timer overflow, or counter overflow, etc.

C60081
Definition

Confidential and Proprietary Information of ZTE CORPORATION 489


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Number of abnormal releases of downlink signaling TBF due to POLL


overflow
Description

C60081 represents number of abnormal releases of downlink signaling


TBF due to POLL overflow.
Measurement Point

C60081 increments when BSC abnormally releases the downlink


signaling TBF due to POLL overflow.

C60082
Definition

Number of abnormal releases of downlink signaling TBF due to N3105


overflow
Description

C60082 represents number of abnormal releases of downlink signaling


TBF due to N3105 overflow.
Measurement Point

C60082 increments when BSC abnormally releases the downlink


signaling TBF due to N3105 overflow.

C60083
Definition

Number of abnormal releases of downlink signaling TBF due to forced


release
Description

C60083 represents number of abnormal releases of downlink signaling


TBF due to forced release.
Measurement Point

C60083 increments when BSC abnormally releases the downlink


signaling TBF due to forced release.

C60084
Definition

Number of abnormal releases of downlink signaling TBF due to dead


suspending of the instance
Description

C60084 represents number of abnormal releases of downlink signaling


TBF due to dead suspending of the instance.

490 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

Measurement Point

C60084 increments when BSC abnormally releases the downlink


signaling TBF due to dead suspending of the instance.

C60085
Definition

Number of abnormal release of downlink signaling TBF due to internal


error
Description

C60085 represents number of abnormal releases of downlink signaling


TBF due to internal error.
Measurement Point

C60085 increments when BSC abnormally releases the downlink


signaling TBF due to internal error.
The internal error refers to abnormal release case except for those
such as forced release, timer overflow, or counter overflow, etc.

C60086
Definition

Number of abnormal release of downlink GPRS data TBF due to POLL


overflow
Description

C60086 represents number of abnormal release of downlink GPRS data


TBF due to POLL overflow.
Measurement Point

C60086 increments when BSC abnormally releases the downlink GPRS


data TBF due to POLL overflow.

C60087
Definition

Number of abnormal release of downlink GPRS data TBF due to N3105


overflow
Description

C60087 represents number of abnormal release of downlink GPRS data


TBF due to N3105 overflow.
Measurement Point

C60087 increments when BSC abnormally releases the downlink GPRS


data TBF due to N3105 overflow.

Confidential and Proprietary Information of ZTE CORPORATION 491


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C60088
Definition

Number of abnormal release of downlink GPRS data TBF due to forced


release
Description

C60088 represents number of abnormal release of downlink GPRS data


TBF due to forced release.
Measurement Point

C60088 increments when BSC abnormally releases the downlink GPRS


data TBF due to forced release.

C60089
Definition

Number of abnormal release of downlink GPRS data TBF due to dead


suspending of the instance
Description

C60089 represents number of abnormal release of downlink GPRS data


TBF due to dead suspending of the instance.
Measurement Point

C60089 increments when BSC abnormally releases the downlink GPRS


data TBF due to dead suspending of the instance.

C60090
Definition

Number of abnormal release of downlink GPRS data TBF due to internal


error
Description

C60090 represents number of abnormal release of downlink GPRS data


TBF due to internal error
Measurement Point

C60090 increments when BSC abnormally releases the downlink GPRS


data TBF due to internal error.
Note: Internal error refers to abnormal release case except for those
such as forced release, timer overflow or counter overflow.

C60091
Definition

492 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

Number of abnormal release of downlink EGPRS data TBF due to POLL


overflow
Description

C60091 represents number of abnormal release of downlink EGPRS


data TBF due to POLL overflow.
Measurement Point

C60091 increments when BSC abnormally releases downlink EGPRS


data TBF due to POLL overflow.

C60092
Definition

Number of abnormal release of downlink EGPRS data TBF due to


N3105 overflow
Description

C60092 represents number of abnormal release of downlink EGPRS


data TBF due to N3105 overflow
Measurement Point

C60092 increments when BSC abnormally releases the downlink


EGPRS data TBF due to N3105 overflow.

C60093
Definition

Number of abnormal release of downlink EGPRS data TBF due to forced


release
Description

C60093 represents number of abnormal release of downlink EGPRS


data TBF due to forced release
Measurement Point

C60093 increments when BSC abnormally releases the downlink


EGPRS data TBF due to forced release.

C60094
Definition

Number of abnormal release of downlink EGPRS data TBF due to dead


suspending of the instance
Description

C60094 represents number of abnormal release of downlink EGPRS


data TBF due to dead suspending of the instance

Confidential and Proprietary Information of ZTE CORPORATION 493


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Measurement Point

C60094 increments when BSC abnormally releases the downlink


EGPRS data TBF due to dead suspending of the instance.

C60095
Definition

Number of abnormal release of downlink EGPRS data TBF due to


internal error
Description

C60095 represents number of abnormal release of downlink EGPRS


data TBF due to internal error
Measurement Point

C60095 increments when BSC abnormally releases the downlink


EGPRS data TBF due to internal error.
Internal error refers to abnormal release case except for those such as
forced release, timer overflow or counter overflow.
Table 50 lists the counters, calculated from above mentioned counters.

TABLE 50 COUNTERS C60301~ C60352

Counter
Description Calculation instruction Remark
Number.

Percentage of CS1
two-digit-decimal
coding scheme in C60011/(C60011+C60012+C
C60301 precision, percentage
uplink GPRS data 60013+ C60014)×100
representation
transmission

Percentage of CS2
two-digit-decimal
coding scheme in C60012/(C60011+C60012+
C60302 precision, percentage
uplink GPRS data C60013+ C60014)×100
representation
transmission
Percentage of CS3
two-digit-decimal
coding scheme in C60013/(C60011+C60012+
C60303 precision, percentage
uplink GPRS data C60013+ C60014)×100
representation
transmission
Percentage of CS4
two-digit-decimal
coding scheme in C60014/(C60011+C60012+
C60304 precision, percentage
uplink GPRS data C60013+ C60014)×100
representation
transmission
Percentage of MCS1 C60015/(C60015+C60016+
two-digit-decimal
coding scheme in C60017+C60018+C60019+C
C60305 precision, percentage
uplink EGPRS data 60020+C60021+C60022+C6
representation
transmission 0023)×100

494 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

Percentage of MCS2 C60016/(C60015+


two-digit-decimal
coding scheme in C60016+C60017+ C60018+
C60306 precision, percentage
uplink EGPRS data C60019 + C60020+ C60021+
representation
transmission C60022+ C60023)×100

Percentage of MCS3 C60017/ ( C60015+C60016+


two-digit-decimal
coding scheme in C60017+C60018+C60019+C
C60307 precision, percentage
uplink EGPRS data 60020+C60021+C60022+C6
representation
transmission 0023)×100

Percentage of MCS4 C60018/(C60015+C60016+


two-digit-decimal
coding scheme in C60017+C60018+C60019+C
C60308 precision, percentage
uplink EGPRS data 60020+C60021+C60022+C6
representation
transmission 0023)×100

C60019/(C60015+C60016+C
Percentage of MCS5
60017+ two-digit-decimal
coding scheme in
C60309 C60018+C60019+C60020+C precision, percentage
uplink EGPRS data
60021+C60022+ C60023)× representation
transmission
100
C60020/
Percentage of MCS6
(C60015+C60016+C60017+ two-digit-decimal
coding scheme in
C60310 C60018+C60019+C60020+C precision, percentage
uplink EGPRS data
60021+C60022+ C60023)× representation
transmission
100
C60021/
Percentage of MCS7
(C60015+C60016+C60017+ two-digit-decimal
coding scheme in
C60311 C60018+C60019+C60020+C precision, percentage
uplink EGPRS data
60021+C60022+ C60023)× representation
transmission
100
C60022/
Percentage of MCS8
(C60015+C60016+C60017+ two-digit-decimal
coding scheme in
C60312 C60018+C60019+C60020+C precision, percentage
uplink EGPRS data
60021+C60022+ C60023)× representation
transmission
100
C60023/
Percentage of MCS9
(C60015+C60016+C60017+ two-digit-decimal
coding scheme in
C60313 C60018+C60019+C60020+C precision, percentage
uplink EGPRS data
60021+C60022+ C60023)× representation
transmission
100
Percentage of CS1
C60024/ two-digit-decimal
coding scheme in
C60314 (C60024+C60025+C60026+ precision, percentage
downlink GPRS data
C60027)×100 representation
transmission
Percentage of CS2
C60025/ two-digit-decimal
coding scheme in
C60315 (C60024+C60025+C60026+ precision, percentage
downlink GPRS data
C60027)×100 representation
transmission
Percentage of CS3
C60026/ two-digit-decimal
coding scheme in
C60316 (C60024+C60025+C60026+ precision, percentage
downlink GPRS data
C60027)×100 representation
transmission
Percentage of CS4
C60027/ two-digit-decimal
coding scheme in
C60317 (C60024+C60025+C60026+ precision, percentage
downlink GPRS data
C60027)×100 representation
transmission

Confidential and Proprietary Information of ZTE CORPORATION 495


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C60028/
Percentage of MCS1
(C60028+C60029+C60030+ two-digit-decimal
coding scheme in
C60318 C60031+C60032+C60033+C precision, percentage
downlink EGPRS data
60034+C60035+ C60036)× representation
transmission
100
C60029/
Percentage of MCS2
(C60028+C60029+C60030+ two-digit-decimal
coding scheme in
C60319 C60031+C60032+C60033+C precision, percentage
downlink EGPRS data
60034+C60035+ C60036)× representation
transmission
100
C60030/
Percentage of MCS3
(C60028+C60029+C60030+ two-digit-decimal
coding scheme in
C60320 C60031+C60032+C60033+C precision, percentage
downlink EGPRS data
60034+C60035+ C60036)× representation
transmission
100
C60031/
Percentage of MCS4
(C60028+C60029+C60030+ two-digit-decimal
coding scheme in
C60321 C60031+C60032+C60033+C precision, percentage
downlink EGPRS data
60034+C60035+ C60036)× representation
transmission
100
C60032/
Percentage of MCS5
(C60028+C60029+C60030+ two-digit-decimal
coding scheme in
C60322 C60031+C60032+C60033+C precision, percentage
downlink EGPRS data
60034+C60035+ C60036)× representation
transmission
100
C60033/
Percentage of MCS6
(C60028+C60029+C60030+ two-digit-decimal
coding scheme in
C60323 C60031+C60032+C60033+C precision, percentage
downlink EGPRS data
60034+C60035+ C60036)× representation
transmission
100
C60034/
Percentage of MCS7
(C60028+C60029+C60030+ two-digit-decimal
coding scheme in
C60324 C60031+C60032+C60033+C precision, percentage
downlink EGPRS data
60034+C60035+ C60036)× representation
transmission
100
C60035/
Percentage of MCS8
(C60028+C60029+C60030+ two-digit-decimal
coding scheme in
C60325 C60031+C60032+C60033+C precision, percentage
downlink EGPRS data
60034+C60035+ C60036)× representation
transmission
100
C60036/
Percentage of MCS9
(C60028+C60029+C60030+ two-digit-decimal
coding scheme in
C60326 C60031+C60032+C60033+C precision, percentage
downlink EGPRS data
60034+C60035+ C60036)× representation
transmission
100
Percentage of CS1
C60037/ two-digit-decimal
coding scheme NACK
C60327 (C60037+C60038+C60039+ precision, percentage
block in GPRS uplink
C60040)×100 representation
data transmission
Percentage of CS2
C60038/ two-digit-decimal
coding scheme NACK
C60328 (C60037+C60038+C60039+ precision, percentage
block in GPRS uplink
C60040)×100 representation
data transmission

496 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

Percentage of CS3
C60039/ two-digit-decimal
coding scheme NACK
C60329 (C60037+C60038+C60039+ precision, percentage
block in GPRS uplink
C60040)×100 representation
data transmission
Percentage of CS4
C60040/ two-digit-decimal
coding scheme NACK
C60330 (C60037+C60038+C60039+ precision, percentage
block in GPRS uplink
C60040)×100 representation
data transmission
Percentage of CS1
coding scheme NACK C60041/ two-digit-decimal
C60331 block in GPRS (C60041+C60042+C60043+ precision, percentage
downlink data C60044)×100 representation
transmission
Percentage of CS2
coding scheme NACK C60042/ two-digit-decimal
C60332 block in GPRS (C60041+C60042+C60043+ precision, percentage
downlink data C60044)×100 representation
transmission
Percentage of CS3
coding scheme NACK C60043/ two-digit-decimal
C60333 block in GPRS (C60041+C60042+C60043+ precision, percentage
downlink data C60044)×100 representation
transmission
Percentage of CS4
coding scheme NACK C60044/ two-digit-decimal
C60334 block in GPRS (C60041+C60042+C60043+ precision, percentage
downlink data C60044)×100 representation
transmission
C60045/
Percentage of MCS1
(C60045+C60046+C60047+ two-digit-decimal
coding scheme NACK
C60335 C60048+C60049+C60050+C precision, percentage
block in EGPRS uplink
60051+C60052+ C60053)× representation
data transmission
100
C60046/
Percentage of MCS2
(C60045+C60046+C60047+ two-digit-decimal
coding scheme NACK
C60336 C60048+C60049+C60050+C precision, percentage
block in EGPRS uplink
60051+C60052+ C60053)× representation
data transmission
100
C60047/
Percentage of MCS3
(C60045+C60046+C60047+ two-digit-decimal
coding scheme NACK
C60337 C60048+C60049+C60050+C precision, percentage
block in EGPRS uplink
60051+C60052+ C60053)× representation
data transmission
100
C60048/
Percentage of MCS4
(C60045+C60046+C60047+ two-digit-decimal
coding scheme NACK
C60338 C60048+C60049+C60050+C precision, percentage
block in EGPRS uplink
60051+C60052+ C60053)× representation
data transmission
100
C60049/
Percentage of MCS5
(C60045+C60046+C60047+ two-digit-decimal
coding scheme NACK
C60339 C60048+C60049+C60050+C precision, percentage
block in EGPRS uplink
60051+C60052+ C60053)× representation
data transmission
100

Confidential and Proprietary Information of ZTE CORPORATION 497


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C60050/
Percentage of MCS6
(C60045+C60046+C60047+ two-digit-decimal
coding scheme NACK
C60340 C60048+C60049+C60050+C precision, percentage
block in EGPRS uplink
60051+C60052+ C60053)× representation
data transmission
100
C60051/
Percentage of MCS7
(C60045+C60046+C60047+ two-digit-decimal
coding scheme NACK
C60341 C60048+C60049+C60050+C precision, percentage
block in EGPRS uplink
60051+C60052+ C60053)× representation
data transmission
100
C60052/
Percentage of MCS8
(C60045+C60046+C60047+ two-digit-decimal
coding scheme NACK
C60342 C60048+C60049+C60050+C precision, percentage
block in EGPRS uplink
60051+C60052+ C60053)× representation
data transmission
100
C60053/
Percentage of MCS9
(C60045+C60046+C60047+ two-digit-decimal
coding scheme NACK
C60343 C60048+C60049+C60050+C precision, percentage
block in EGPRS uplink
60051+C60052+ C60053)× representation
data transmission
100

Percentage of MCS1 C60054/


coding scheme NACK (C60054+C60055+C60056+ two-digit-decimal
C60344 block in EGPRS C60057+C60058+C60059+C precision, percentage
downlink data 60060+C60061+ C60062)× representation
transmission 100

Percentage of MCS2 C60055/


coding scheme NACK (C60054+C60055+C60056+ two-digit-decimal
C60345 block in EGPRS C60057+C60058+C60059+C precision, percentage
downlink data 60060+C60061+ C60062)× representation
transmission 100

Percentage of MCS3 C60056/


coding scheme NACK (C60054+C60055+C60056+ two-digit-decimal
C60346 block in EGPRS C60057+C60058+C60059+C precision, percentage
downlink data 60060+C60061+ C60062)× representation
transmission 100

Percentage of MCS4 C60057/


coding scheme NACK (C60054+C60055+C60056+ two-digit-decimal
C60347 block in EGPRS C60057+C60058+C60059+C precision, percentage
downlink data 60060+C60061+ C60062)× representation
transmission 100

Percentage of MCS5 C60058/


coding scheme NACK (C60054+C60055+C60056+ two-digit-decimal
C60348 block in EGPRS C60057+C60058+C60059+C precision, percentage
downlink data 60060+C60061+ C60062)× representation
transmission 100

Percentage of MCS6 C60059/


coding scheme NACK (C60054+C60055+C60056+ two-digit-decimal
C60349 block in EGPRS C60057+C60058+C60059+C precision, percentage
downlink data 60060+C60061+ C60062)× representation
transmission 100

498 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

Percentage of MCS7 C60060/


coding scheme NACK (C60054+C60055+C60056+ two-digit-decimal
C60350 block in EGPRS C60057+C60058+C60059+C precision, percentage
downlink data 60060+C60061+ C60062)× representation
transmission 100

Percentage of MCS8 C60061/


coding scheme NACK (C60054+C60055+C60056+ two-digit-decimal
C60351 block in EGPRS C60057+C60058+C60059+C precision, percentage
downlink data 60060+C60061+ C60062)× representation
transmission 100

Percentage of MCS9 C60062/


coding scheme NACK (C60054+C60055+C60056+ two-digit-decimal
C60352 block in EGPRS C60057+C60058+C60059+C precision, percentage
downlink data 60060+C60061+ C60062)× representation
transmission 100

Network Service Sub layer


Counters
NS sub layer counters takes NSVC as measurement unit. These counters
provide statistics such as data transmission, signaling interaction, and
abnormal link transmission of NSVC link. Table 51 lists measurement
counters.

TABLE 51 NS SUB LAYER COUNTERS

Counter
Definition
Number.
C50001 Number of bytes sent by NS sub layer
C50002 Number of bytes received by NS sub layer
C50003 Number of PDU data sent by NS sub layer
C50004 Number of PDU data received by NS sub layer
C50005 Number of PDU data discarded by NS sub layer
C50006 Number of reset messages send to opposite end by NS sub layer
C50007 Number of received reset messages sent by opposite end
C50008 Number of reset confirm messages send to opposite end by NS sub layer
C50009 Number of received reset confirm messages sent by opposite end
C50010 Number of blocking messages send to opposite end by NS sub layer
C50011 Number of received blocking messages sent by opposite end
Number of blocking confirm messages send to opposite end by NS sub
C50012
layer
C50013 Number of received blocking confirm messages sent by opposite end
C50014 Number of unblocking messages send to opposite end by NS sub layer

Confidential and Proprietary Information of ZTE CORPORATION 499


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Counter
Definition
Number.
C50015 Number of received unblocking messages sent by opposite end
Number of unblocking confirm messages send to opposite end by NS sub
C50016
layer
C50017 Number of received unblocking messages sent by opposite end
Number of abnormal cases in NS transmitting procedure due to network
C50018
fault
Number of abnormal cases in NS transmitting procedure due to O&M
C50019
interference
Number of abnormal cases in NS transmitting procedure due to
C50020
equipment fault
Number of abnormal cases in NS transmitting procedure due to NSVC
C50021
block
Number of abnormal cases in NS transmitting procedure due to unknown
C50022
NSVC
Number of abnormal cases in NS transmitting procedure due to protocol
C50023
error
C50024 Number of failed test procedure (after exceeding the maximum times)
Number of failed blocking procedure (after exceeding the maximum
C50025
times)
Number of failed unblocking procedure (after exceeding the maximum
C50026
times)

Network Service Sub layer Counters


Explanation
C50001
Definition

Number of bytes sent by NS sub layer


Description

C50001 records number of bytes sent by NS sub layer.


Measurement Point

FR accumulates number of bytes send each time.

C50002
Definition

Number of bytes received by NS sub layer


Description

500 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

C50002 records number of bytes received by NS sub layer.


Measurement Point

FR accumulates number of bytes received from Gb interface.

C50003
Definition

Number of PDU data sent by NS sub layer


Description

C50003 records number of PDU sent by NS sub layer.


Measurement Point

FR accumulates one every time when sending a PDC to Gb.

C50004
Definition

Number of PDU data received by NS sub layer


Description

C50004 records number of PDU received by NS sub layer.


Measurement Point

FR accumulates one every time when receiving a PDC from Gb.

C50005
Definition

Number of PDU data discarded by NS sub layer


Description

C50005 records number of PDU discarded by NS sub layer.


Measurement Point

FR accumulates when discarding PDU due to congestion.

C50006
Definition

Number of reset messages sent to opposite end by NS sub layer


Description

C50006 records number of reset messages sent to opposite end by NS


sub layer.
Measurement Point

Confidential and Proprietary Information of ZTE CORPORATION 501


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C50006 increments when NSC sending NS_RESET PDU.

C50007
Definition

Number of received reset messages sent by opposite end


Description

C50007 records number of received reset messages sent by opposite


end.
Measurement Point

C50007 increments when NSC receiving NS_RESET PDU.

C50008
Definition

Number of reset confirm messages send to opposite end by NS sub


layer
Description

C50008 records number of reset confirm messages sent to opposite


end by NS sub layer.
Measurement Point

C50008 increments when NSC sending NS_RESETACK PDU.

C50009
Definition

Number of received reset confirm messages sent by opposite end


Description

C50009 increments records number of received reset confirm


messages sent by opposite end.
Measurement Point

Definition

C50009 increments when NSC receiving NS_RESET ACK PDU.

C50010
Definition

Number of blocking messages sent to opposite end by NS sub layer


Description

502 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

C5001 records Number of blocking messages sent to opposite end by


NS sub layer.
Measurement Point

Definition

C50010 increments when NSC sending NS_BLOCK PDU.

C50011
Definition

Number of received blocking messages sent by opposite end


Description

C50011 records Number of received blocking messages sent by


opposite end.
Measurement Point

C50011 increments when NSC receiving NS_BLOCK PDU.

C50012
Definition

Number of blocking confirm messages send to opposite end by NS sub


layer
Description

C50012 records Number of blocking confirm messages send to


opposite end by NS sub layer.
Measurement Point

C50012 increments when NSC sending NS_BLOCK ACK PDU.

C50013
Definition

Number of received blocking confirm messages sent by opposite end


Description

C50013 records Number of received blocking confirm messages sent


by opposite end.
Measurement Point

C50013 increments when NSC receiving NS_BLOCK ACK PDU.

C50014
Definition

Confidential and Proprietary Information of ZTE CORPORATION 503


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Number of unblocking messages sent to opposite end by NS sub layer


Description

C50014 records Number of unblocking messages send to opposite


end by NS sub layer.
Measurement Point

C50014 increments when NSC sending NS_UNBLOCK PDU.

C50015
Definition;

Number of received unblocking messages sent by opposite end


Description

C50015 records Number of received unblocking messages sent by


opposite end.
Measurement Point

C50015 increments when NSC receiving NS_UNBLOCK PDU.

C50016
Definition

Number of unblocking confirm messages send to opposite end by NS


sub layer
Description

C50016 records number of unblocking confirm messages sent to


opposite end by NS sub layer.
Measurement Point

C50016 increments when NSC sending NS_UNBLOCK ACK PDU.

C50017
Definition

Number of received unblocking messages sent by opposite end


Description

C50017 records Number of received unblocking messages sent by


opposite end.
Measurement Point

C50017 increments when NSC receiving NS_UNBLOCK ACK PDU.

504 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

C50018
Definition

Number of number of abnormal cases in NS transmitting procedure


due to network fault
Description

C50018 records Number of received unblocking messages sent by


opposite end.
Measurement Point

C50018 increments when NSVC receiving frame trunk reporting that


fault cause is transmission network fault.

C50019
Definition

Number of number of abnormal cases in NS transmitting procedure


due to O&M interference
Description

C50019 records number of abnormal cases in NS transmitting


procedure due to O&M interference.
Measurement Point

C50019 increments when NSVC receiving background blocking request

C50020
Definition

Number of number of abnormal cases in NS transmitting procedure


due to equipment fault
Description

C50020 records number of number of abnormal cases in NS


transmitting procedure due to equipment fault.
Measurement Point

C50020 increments when NSVC receiving frame trunk reporting that


fault cause is transmission network fault.

C50021
Definition

Number of number of abnormal cases in NS transmitting procedure


due to NSVC block
Description

Confidential and Proprietary Information of ZTE CORPORATION 505


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C50021 records number of number of abnormal cases in NS


transmitting procedure due to NSVC block.
Measurement Point

C50021 increments when the cause of sending status message is NSVC


BLOCKED

C50022
Definition

Number of number of abnormal cases in NS transmitting procedure


due to unknown NSVC
Description

C50022 records number of number of abnormal cases in NS


transmitting procedure due to unknown NS-VC.
Measurement Point

C50022 increments when the cause of sending status message is NSVC


identification error.

C50023
Definition

Number of number of abnormal cases in NS transmitting procedure


due to protocol error
Description

C50023 records number of number of abnormal cases in NS


transmitting procedure due to protocol error.
Measurement Point

C50023 increments when cause of sending status message is protocol


error. It includes PDU semantic error, PDU incompatible with protocol,
protocol error, invalid necessary IE and missing necessary IE.

C50024
Definition

Number of failed test procedure (after exceeding the maximum times)


Description

C50024 records number of failed test procedure after exceeding the


maximum times.
Measurement Point

C50024 increments when transmission time of NSVC link NS_ALIVE


PDU exceeds the maximum retransmission time.

506 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

C50025
Definition

Number of failed blocking procedure after exceeding the maximum


times
Description

C50025 records number of failed blocking procedure after exceeding


the maximum times.
Measurement Point

C50025 increments when transmission time of NSVC link NS_BLOCK


PDU exceeds the maximum retransmission time.

C50026
Definition

Number of failed unblocking procedure after exceeding the maximum


times
Description

C50026 records number of failed unblocking procedure after


exceeding the maximum times.
Measurement Point

C50026 increments when transmission of NSVC link NS_UNBLOCK PDU


exceeds the maximum retransmission time.

BSSGP Layer Counters


Table 52 lists all BSSGP layer counters.

TABLE 52 BSSGP LAYER COUNTERS

Counter
Description
Number.
C51001 Number of BSC receiving PTP packet paging
C51002 Number of BSC receiving PTP circuit paging
C51003 Number of Wireless status PDU messages sent by BSC
C51004 Number of Status messages sent by BSC
C51005 Number of Status messages received by BSC
C51006 Number of Flow control messages sent by BSC
C51007 Number of Flow control ACK messages received by BSC
C51008 Total number of requests of discarding message by BSSGP layer user

Confidential and Proprietary Information of ZTE CORPORATION 507


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Counter
Description
Number.
Number of Wireless status messages sent by BSC due to Losing wireless
C51009
association with MS
C51010 Number of Wireless status messages sent by BSC due to Bad link quality
Number of Wireless status messages sent by BSC due to Cell reselection
C51011
command
C51012 Number of Status messages sent with cause BVCI Unknown
C51013 Number of Status messages sent with cause Cell service congestion
C51014 Number of Status messages sent with cause of protocol error
C51015 Number of Status messages sent with cause Processor overload
C51016 Number of Status messages received with cause BVCI Unknown
C51017 Number of Status messages received with cause Cell service congestion
C51018 Number of Status messages received with cause of protocol error
C51019 Number of Status messages received with cause Processor overload
C51020 Number of Pause messages received by BSC
C51021 Number of Pause ACK messages returned by SGSN
C51022 Number of Pause un ACK messages returned by SGSN
C51023 Number of FLUSH-LL PDU messages received by BSC from SGSN
C51024 Number of FLUSH-LL-ACK messages sent by BSC
C51025 Number of BVC blocking messages that BSS sends
C51026 Number of BVC blocking ACK messages that BSS receives
C51027 Number of BVC unblocking messages that BSS sends
C51028 Number of BVC unblocking ACK messages that BSS receives
C51029 Number of BVC reset messages that BSS sends
C51030 Number of BVC reset messages that BSS receives
C51031 Number of BVC reset ACK messages returned by BSS
C51032 Number of BVC reset ACK messages that BSS receives

BSSGP Counters Explanation


C51001
Definition

Number of reception of PTP packet paging of BSC


Description

C51001 records number of BSC receiving PTP packet paging.


Measurement Point

508 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

C51001 increments one every time when BSC receives a PTP packet
paging.

C51002
Definition

Number of reception of PTP circuit paging by BSC


Description

C51002 records number of BSC receiving PTP circuit paging.


Measurement Point

C51002 increments one every time BSC receiving a PTP circuit paging
from GS interface.

C51003
Definition

Number of Wireless state PDU messages sent by BSC


Description

C51003 records number of Wireless state PDU messages sent by BSC.


Measurement Point

C51003 increments one every time BSC transmitting a Radio Status to


SGSN, and the message transmits when POLLING timer overflows or
T3195 timer overflows.

C51004
Definition

Number of “State” messages sent by BSC


Description

C51004 records number of State messages sent by BSC


Measurement Point

C51004 increments one every time when BSC sends BSSGP STATUS
message to SGSN. PDC module returns BSSGP STAUS message to
SGSN when it receives messages sent by SGSN that not satisfy
receiving conditions.

C51005
Definition

Number of “State” messages received by BSC


Description

Confidential and Proprietary Information of ZTE CORPORATION 509


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C51005 records number of State messages received by BSC.


Measurement Point

C51005 increments one every time when BSC receives a BSSGP STAUS
message sent by SGSN.

C51006
Definition

Number of Flow control messages sent by BSC


Description

C51006 records number of Flow control messages sent by BSC.


Measurement Point

C51006 increments one every time when BSC sends a BVC flow control
message to SGSN.

C51007
Definition

Number of Flow control ACKNOWLDGMENT messages received by BSC


Description

C51007 records number of Flow control ACKNOWLDGMENT messages


received by BSC
Measurement Point

C51007 increments one every time when BSC receives a BVC flows
control ACKNOWLDGMENT message sent by SGSN that satisfy
conditions.

C51008
Definition

Total number of requests of discarding message by BSSGP layer user


Description

The counter records total number of requests of discarding message by


BSSGP layer user.
Measurement Point

The counter increments to one every time BSC sending LLC DISCARD
message to SGSN.

C51009
Definition

510 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

Number of Wireless state messages sent by BSC due to losing wireless


association with MS message
Description

C51009 records number of Wireless state messages sent by BSC due


to losing wireless association with MS message.
Measurement Point

C51009 increments when POLLLING timer overflows message.

C51010
Definition

Number of Wireless state messages sent by BSC due to Bad link


quality
Description

C51010 represents number of Wireless state messages sent by BSC


due to Cell service congesting message.
Measurement Point

C51010 increments when BSC sends wireless state message due to


Cell service congesting message.

C51011
Definition

Number of Wireless state messages sent by BSC due to Cell reselection


command message
Description

C51011 records number of Wireless state messages sent by BSC due


to Cell reselection command message.
Measurement Point

C51010 increments when BSC sending wireless state message due to


Cell reselection command message.

C51012
Definition

Number of State messages sent with cause Unknown BVCI message


Description

C51012 records number of State messages sent with cause Unknown


BVCI message.
Measurement Point

Confidential and Proprietary Information of ZTE CORPORATION 511


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C51012 increments when BSC sends wireless state message due to


Unknown BVCI message.

C51013
Definition

Number of State messages sent with cause Cell service congesting


message
Description

C51013 records number of State messages sent with cause Cell service
congesting message.
Measurement Point

C51013 increments when BSC sending STATUS message due to cell


service congestion message.

C51014
Definition

Number of State messages sent with cause of protocol error


Description

C51014 records number of State messages sent with cause of protocol


error message.
Measurement Point

C51014 increments when BSC receives SGSN data with


coding/decoding error message.

C51015
Definition

Number of State messages sent with cause Processor overload


Description

C51015 records number of State messages sent with cause Processor


overload message.
Measurement Point

The counter increments to one when BSC sends STATUS message with
‘processor overload cause’ message.

C51016
Definition

Number of State messages received with cause Unknown BVCI


message

512 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

Description

C51016 records number of State messages received with cause


Unknown BVCI message.
Measurement Point

C51016 increments when BSC receives STATUS message with cause


Unknown BVCI message.

C51017
Definition

Number of State messages received with cause Cell service congesting


Description

C51017 records number of State messages received with cause Cell


service congesting message.
Measurement Point

C51017 increments when BSC receiving STATUS message with cell


service congestion cause.

C51018
Definition

Number of State messages received with cause of protocol error


Description

C51018 records number of State messages received with cause of


protocol error message.
Measurement Point

C51016 increments when BSC receives STATUS message with protocol


error cause message.

C51019
Definition

Number of State messages received with cause Processor overload


Description

C51019 records number of State messages received with cause


Processor overload
Measurement Point

C51019 increments when BSC receives STATUS message with


processor overload cause message.

Confidential and Proprietary Information of ZTE CORPORATION 513


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C51020
Definition

Number of Pause messages received by BSC


Description

C51020 records number of Pause messages received by BSC


Measurement Point

C51020 increments every time BSC receives SUSPEND message from


MS.

C51021
Definition

Number of “Pause Acknowledged” messages returned by SGSN


Description

C51021 records number of Pause Acknowledged messages returned by


SGSN.
Measurement Point

C51021 increments every time when BSC receives a SUSPEND ACK


message sent by SGSN satisfying conditions.

C51022
Definition

Number of Pause un Acknowledged messages returned by SGSN

Description

C51022 records number of Pause un Acknowledged messages returned


by SGSN
Measurement Point

C51022 increments every time BSC receiving a SUSPEND NACK


message sent by SGSN satisfying conditions

C51023
Definition

Number of FLUSH-LL PDU messages received by BSC from SGSN


Description

C51023 records number of FLUSH-LL PDU messages received by BSC


from SGSN.
Measurement Point

514 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

C51023 increments every time when BSC receives a FLUSH_LL PDU


message sent by SGSN

C51024
Definition

Number of FLUSH-LL-Acknowledged messages sent by BSC


Description

C51024 records number of FLUSH-LL-Acknowledged messages sent


by BSC.
Measurement Point

C51024 increments every time when BSC receives a FLUSH_LL_ACK


message sent by SGSN.

C51025
Definition

Number of BVC blocking messages that BSS sends


Description

C51025 records number of BVC blocking messages that BSS sends.


Measurement Point

C51025 increments every time when BSC sends a BVC BLOCK


message.

C51026
Definition

Number of BVC blocking ACKNOWLDGMENT messages that BSS


receives
Description

C51026 records number of BVC blocking ACKNOWLDGMENT messages


that BSS receives.
Measurement Point

C51026 increments every time when BSC receives BVC BLOCK ACK
message sent by SGSN satisfying conditions.

C51027
Definition

Number of BVC unblocking messages that BSS sends

Confidential and Proprietary Information of ZTE CORPORATION 515


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Description

C51027 records number of BVC unblocking messages that BSS sends.


Measurement Point

C51027 increments every time when BSC sending BVC UNBLOCK


message to SGSN.

C51028
Definition

Number of BVC unblocking ACKNOWLDGMENT messages that BSS


receives
Description

C51028 records number of BVC unblocking ACKNOWLDGMENT


messages that BSS receives.
Measurement Point

C51028 increments every time when BSC receives BVC UNBLCOK ACK
message.

C51029
Definition

Number of BVC reset messages that BSS sends


Description

C51029 records number of BVC reset messages that BSS sends.


Measurement Point

C51029 increments every time when BSC sends BVC RESET message
to SGSN.

C51030
Definition

Number of BVC reset messages that BSS receives


Description

C51030 records number of BVC reset messages that BSS receives.


Measurement Point

C51030 increments every time when BSC receiving BVC RESET


message sent by SGSN.

C51031
Definition

516 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

Number of “BVC reset ACKNOWLDGMENT” messages returned by BSS


Description

C51031 records number of BVC reset ACKNOWLDGMENT messages


returned by BSS
Measurement Point

C51031 increments every time when BSC sends BVC RESET ACK
message to SGSN

C51032
Definition

Number of BVC reset ACKNOWLDGMENT messages that BSS receives


Description

C51032 records number of BVC reset ACKNOWLDGMENT messages


that BSS receives.
Measurement Point

C51032 increments every time when BSC receives BVC RESET ACK
message sent by SGSN.

NSE Performance Counters


TABLE 53 NSE PERFORM ANCE COUNTERS

Counter
Definition
Number.
C52001 Number of CS Paging that BSS receives
C52002 Number of PS Paging that BSS receives
C52003 Total number of status messages sent
C52004 Total number of Status messages received
C52005 Number of Status messages sent with cause BVCI Unknown
C52006 Number of Status messages sent with cause Cell service congestion
C52007 Number of Status messages sent with cause of protocol error
C52008 Number of Status messages sent with cause Processor overload
Number of Status messages sent with cause of Semantically incorrect
C52009
PDU
Number of Status messages sent with cause Invalid mandatory
C52010
information element
C52011 Number of Status messages sent with cause Missing mandatory IE
C52012 Number of Status messages sent with cause Missing conditional IE

Confidential and Proprietary Information of ZTE CORPORATION 517


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Counter
Definition
Number.
C52013 Number of Status messages sent with cause Unexpected conditional IE
C52014 Number of Status messages sent with cause Conditional IE error
C52015 Number of Status messages sent with cause Conditional IE error
C52016 Number of Status messages received with cause BVCI Unknown
C52017 Number of Status messages received with cause Cell service congestion
C52018 Number of “Status” messages received with cause of protocol error
C52019 Number of Status messages received with cause Processor overload
C52020 Number of Status messages received with cause BVC blocking
Number of Status messages received with cause Semantically incorrect
C52021
PDU
C52022 Number of Status messages received with cause Invalid mandatory IE
C52023 Number of Status messages received with cause Missing mandatory IE
C52024 Number of Status messages received with cause Missing conditional IE
Number of Status messages received with cause Unexpected conditional
C52025
IE
C52026 Number of Status messages received with cause Conditional IE error
Number of Status messages received with cause PDU not compatible
C52027
with the protocol state
C52028 Number of Status messages received with cause SGSN congestion
C52029 Number of Signaling BVC reset messages sent by Gb
C52030 Number of Signaling BVC reset ACK messages received by Gb
C52031 Number of Signaling BVC reset messages received by Gb
C52032 Number of Signaling BVC reset ACK messages sent by Gb

NSE Performance Counters Explanation


C52001
Definition

Number of CS Paging that BSS receives


Description

C52001 records Number of Paging CS messages received by NSE


entity on BSC.
Measurement Point

C52001 increments every time when BSC receives PSGING CS


message.

518 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

C52002
Definition

Number of PS Paging that BSS receives


Description

C52002 records number of Paging PS messages received by NSE entity


on BSC.
Measurement Point

C52001 increments when BSC receives PSGING PS message.

C52003
Definition

Total number of status messages sent


Description

C52003 records total number of STATUS messages sent from NSE


entity.
NSE entity send STATUS message to opposite end entity when NSE
entity receives downlink BSSGP PDU and abnormal cases happens. The
message indicates following abnormal cases:
y BVCI unknown
y cell traffic congestion
y Protocol error
y Processor overload
y Semantically incorrect PDU
y Invalid mandatory information
y Missing mandatory IE
y Missing conditional IE
Measurement Point

C52003 increments when NSE entity in BSC sends message with


STATUS type to the opposite end entity

C52004
Definition

Total number of status messages received


Description

C52004 records total number of STATUS messages returned from


SGSN.

Confidential and Proprietary Information of ZTE CORPORATION 519


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

When BSSGP PDU send to SGSN is abnormal, NSE receives STATUS


message returned from the opposite end. The message indicates the
following abnormal cases:
y BVCI unknown
y cell traffic congestion
y Protocol error
y Processor overload
y Semantically incorrect PDU
y Invalid mandatory information
y Missing mandatory IE
y Missing conditional IE

Measurement Point

C52005 get increments when NSE receives STATUS message.

C52005
Number of “Status” messages sent with cause “BVCI Unknown”
Description

C52005 records number of STATUS messages sent to opposite end


entity from NSE, with cause “BVCI Unknown”.
Measurement Point

C52005 increments when NSE sends STATUS message to opposite end


entity with cause BVCI Unknown.

C52006
Definition

Number of “Status” messages sent due to cell service congestion


Description

Number of STATUS messages sent due to cell service congestion sent


to opposite end entity from NSE
Measurement Point

C52006 increments when NSE sending STATUS message to opposite


end entity with cause Cell traffic congestion

C52007
Definition

Number of Status messages sent with cause of protocol error

520 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

Description

C52007 number of STATUS messages sent to opposite end entity from


NSE with cause of Protocol error.
Measurement Point

C52007 increments when NSE sends STATUS message to opposite end


entity with cause Protocol error.

C52008
Definition

Number of Status messages sent with cause “Processor overload”


Description

C52008 records number of STATUS messages sent, with cause Protocol


error sent to opposite end entity from NSE.
Measurement Point

C52008 increments when NSE sending STATUS message to opposite


end entity with cause “Protocol error”

C52009
Definition

Numbers of “Status” messages sent with cause of “Semantically


incorrect PDU”
Description

Number of STATUS messages sent with cause “Semantically incorrect


PDU” send to opposite end entity from NSE
Measurement Point

The counter increments to one when NSE sending STATUS message to


opposite end entity with cause “Semantically incorrect PDU”

C52010
Definition

Number of “Status” messages sent with cause “Invalid mandatory


information element”
Description

Number of STATUS messages sent to opposite end entity from NSE


with cause “Invalid mandatory information”
Measurement Point

The counter increments to one when NSE sending STATUS message to


opposite end entity with cause “Invalid mandatory information”

Confidential and Proprietary Information of ZTE CORPORATION 521


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C52011
Definition

Number of “Status” messages sent with cause “Missing mandatory IE”


Description

Number of STATUS messages sent to opposite end entity from NSE


with cause “Missing mandatory IE”
Measurement Point

The counter increments to one when NSE sending STATUS message to


opposite end entity with cause “Missing mandatory IE”

C52012
Definition

Number of “Status” messages sent with cause “Missing conditional IE”


Description

Number of STATUS messages sent with cause “Missing conditional IE”


to the opposite end entity from NSE
Measurement Point

The counter increments to one when NSE sending STATUS message to


opposite end entity with cause “Missing conditional IE”

C52013
Definition

Number of “Status” messages sent with cause “Unexpected conditional


IE”
Description

Number of STATUS messages sent with cause “Unexpected conditional


IE” to opposite end entity from NSE
Measurement Point

The counter increments to one when NSE sending STATUS message to


opposite end entity with cause “Unexpected conditional IE”

C52014
Definition

Number of “Status” messages sent with cause “Conditional IE error”


Description

Number of STATUS messages sent with cause “Conditional IE error” to


opposite end entity from NSE

522 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

Measurement Point

The counter increments to one when NSE sending STATUS message to


opposite end entity with cause “Conditional IE error”

C52015
Definition

Number of “Status” messages sent with cause “PDU not compatible


with the protocol state”
Description

Number of STATUS messages sent with cause “PDU not compatible


with the protocol state” to the opposite end entity from NSE
Measurement Point

The counter increments to one when NSE sending STATUS message to


opposite end entity with cause “PDU not compatible with the protocol
state”

C52016
Definition

Number of “Status” messages received with cause “BVCI Unknown”


Description

The measurement value records number of STATUS messages


received with cause “BVCI Unknown”
Measurement Point

The counter increments to one when PCU receiving STATUS message


with cause “BVCI Unknown”

C52017
Definition

Number of “Status” messages received with cause “Cell service


congestion”

Description

Number of STATUS messages received by PCU with cause “Cell traffic


congestion” from SGSN
Measurement Point

The counter increments to one when PCU receiving STATUS message


with cause “Cell traffic congestion”

Confidential and Proprietary Information of ZTE CORPORATION 523


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C52018
Definition

Number of “Status” messages received with cause of protocol error


Description

The measurement value records number of received STATUS


messages with cause “Protocol error”
Measurement Point

The counter increments to one when PCU receiving STATUS message


with cause “Protocol error”

C52019
Definition

Number of “Status” messages received with cause “Processor


overload”
Description

Number of STATUS messages received by PCU with cause “Processor


overload” from SGSN.
Measurement Point

The counter increments to one when PCU receiving STATUS message


with cause “Processor overload”

C52020
Definition

Number of “Status” messages received with cause “BVC blocking”

Description

Number of STATUS messages received by PCU with cause “BVCI-


blocked” from SGSN.
Measurement Point

The counter increments to one when PCU receiving STATUS message


with cause “BVCI-blocked”
C52021

Definition

Number of “Status” messages received with cause “Semantically


incorrect PDU”
Description

524 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

The measurement value records number of received STATUS


messages with cause “Semantically incorrect PDU”.
Measurement Point

The counter increments to one when PCU receiving STATUS message


with cause “Semantically incorrect PDU”

C52022
Definition

Number of “Status” messages received with cause “Invalid mandatory


IE”
Description

The measurement value records number of received STATUS


messages with cause “Invalid mandatory IE”.
Measurement Point

The counter increments to one when PCU receiving STATUS message


with cause “Invalid mandatory IE”

C52023
Definition

Number of “Status” messages received with cause “Missing


mandatory IE”
Definition

The measurement value records number of received STATUS


messages with cause “Missing mandatory IE”.
Measurement Point

The counter increments to one when PCU receiving STATUS message


with cause “Missing mandatory IE”

C52024
Definition

Number of “Status” messages received with cause “Missing conditional


IE”
Definition

The measurement value records number of received STATUS


messages with cause “Missing conditional IE”.
Measurement Point

The counter increments to one when PCU receiving STATUS message


with cause “Missing conditional IE”

Confidential and Proprietary Information of ZTE CORPORATION 525


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C52025
Definition

Number of “Status” messages received with cause “Unexpected


conditional IE”
Description

The measurement value records number of received STATUS


messages with cause “Unexpected conditional IE”
Measurement Point

The counter increments to one when PCU receiving STATUS message


with cause “Unexpected conditional IE”

C52026
Definition

Number of “Status” messages received with cause “Conditional IE


error”
Description

The measurement value records number of received STATUS


messages with cause “Conditional IE error”
Measurement Point

The counter increments to one when PCU receiving STATUS message


with cause “Conditional IE error”

C52027
Definition

Number of “Status” messages received with cause “PDU not compatible


with the protocol state”
Description

The measurement value records number of received STATUS


messages with cause “PDU not compatible with the protocol state”.
Measurement Point

The counter increments to one when PCU receiving STATUS message


with cause “PDU not compatible with the protocol state”

C52028
Definition

Number of “Status” messages received with cause “SGSN congestion”


Description

526 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

The measurement value records number of received STATUS


messages with cause “SGSN congestion”.
Measurement Point

The counter increments to one when PCU receiving STATUS message


with cause “SGSN congestion”

C52029
Definition

Number of “Signaling BVC reset” messages sent by Gb


Description

Number of PCU sending signaling BVC reset through Gb.


Measurement Point

The counter increments when the NSE entity on BSC sending message
with BVC-RESET type and BVCI is zero
C52030

Definition

Number of “Signaling BVC reset ACK” messages received by Gb


Description

Number of “Signaling BVC reset ACK” messages received by PCU


Measurement Point

The counter increments when the NSE entity on BSC receiving


message with BVC-RESET-ACK type and BVCI is zero

C52031
Definition

Number of “Signaling BVC reset” messages received by Gb


Description

Number of “Signaling BVC reset” messages received by PCU.


Measurement Point

The counter increments when the NSE entity on BSC receiving


message with BVC-RESET type and BVCI is zero

C52032
Definition

Number of “Signaling BVC reset ACK” messages sent by Gb


Description

Confidential and Proprietary Information of ZTE CORPORATION 527


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

After receiving “Signaling BVC reset” messages from Gb interface, PCU


will return “Signaling BVC reset ACK” messages.
Measurement Point

The counter increments when the NSE entity on BSC sending message
with BVC-RESET-ACK type and BVCI is zero

Resource Management Counters


Table 54 represents Counters for Resource Management.

TABLE 54 RESOURCE M AN AGEMENT COUNTERS

Counter
Definition
Number.
C61001 Number of forced retracting dynamic PDCH by BSC
C61002 Number of successfully activating dynamic PDCH
C61003 Number of failed activating dynamic PDCH
C61004 Number of PDCH failure recovery
C61005 Number of PDCH failure recovery
C61006 Number of cell attempting uplink assignment due to ONE PHASE access
C61007 Number of cell successful uplink assignment due to ONE PHASE access
Number of cell attempts for uplink assignment due to single block packet
C61008
access
Number of cell successful uplink assignment due to single block packet
C61009
access
C61010 Number of cell attempt uplink assignment due to response paging
C61011 Number of cell successful uplink assignment due to response paging
C61012 Number of cell attempts for uplink assignment due to cell updating
C61013 Number of cell successful uplink assignment due to cell updating
Number of cell attempts for uplink assignment due to mobility
C61014
management
C61015 Number of cell successful uplink assignment due to mobility management
C61016 Number of cell attempts for uplink assignment due to TWO PHASE access
C61017 Number of cell successful uplink assignment due to TWO PHASE access
C61018 Number of cell attempts for uplink assignment due to short access
C61019 Number of cell successful uplink assignment due to short access
C61020 Number of messages in PGH-AGCH queue
C61021 Number of assignment messages in PPCH-PAGCH queue
C61022 Number of paging messages deleted from PCH queue
C61023 Number of packet paging messages deleted from PPCH queue

528 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

Counter
Definition
Number.
C61024 Number of paging messages send unsuccessfully from cell
C61025 Average Number of available PDCH
C61026 Maximum Number of available PDCH
C61027 Minimum Number of available PDCH
C61028 Average Number of occupied PDCH
C61029 Maximum Number of occupied PDCH
C61030 Minimum Number of occupied PDCH
C61031 Average number of messages in PCH-AGCH queue
C61032 Average number of messages in PPCH-PAGCH queue

Resource Management Counters


Explanation
C61001
Definition

Number of forced retracting dynamic PDCH by BSC


Description

The counter indicates number of dynamic PDCH converting into TCH


Measurement Point

The counter increments when dynamic channel forcibly converts from


PS state to CS state.

C61002
Definition

Number of successfully activating dynamic PDCH


Description

The counter indicates number of dynamic channel successfully


converting from TCH to PDCH
Measurement Point

The counter increments when the flow of dynamic channel converts


from TCH to PDCH succeeds

C61003
Definition

Confidential and Proprietary Information of ZTE CORPORATION 529


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Number of failed activating dynamic PDCH


Description

The counter indicates failure number of dynamic channel converting


from TCH to PDCH
Measurement Point

When dynamic channel fails to converts from TCH to PDCH, The


counter increments to accumulate

C61004
Definition

Number of PDCH failure recovery


Description

The counter indicates number of PDCH failure


Measurement Point

The counter increments when PDCH blocks due to blocking cause

C61005
Definition

Number of PDCH failure recovery


Description

The counter indicates number of PDCH failure blocking recovery


Measurement Point

The counter increments when PDCH is unblocked due to blocking


recovery

C61006
Definition

Number of cell attempting uplink assignment due to ONE PHASE access


Description

The counter records number of correct channel requests after receiving


the access because that is ONE PHASE access
Measurement Point

After receiving channel request, BSC checks whether the cell, the
channel requests and the access cause are correct. C61006
accumulates, if access cause is ONE PHASE access and channel request
is correct.

530 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

C61007
Definition

Number of cell successful uplink assignment due to ONE PHASE access


Description

The counter records number of successful assignments after receiving


ONE PHASE access cause
Measurement Point

When the cell configures PCCCH in the case of ONE PHASE access, The
counter increments after BSC database successfully assigns related
resource. When the cell does not configure PCCCH in the case of ONE
PHASE access, the counter increments after BSC sends instant
assignment. It then receives message returned by BTS, which is also
send to MS.

C61008
Definition

Number of cell attempts for uplink assignment due to single block


packet access
Description

The counter records number of correct channel requests after receiving


Single Block access cause.
Measurement Point

When the cell configures PCCCH, after receiving channel request, BSC
checks whether the cell the channel requests and the access cause are
correct. C61008 accumulates for correct channel request and access
cause is single block access.

C61009
Definition

Number of cell successful uplink assignment due to single block packet


access
Description

The counter records number of successful assignment after receiving


Single Block access cause
Measurement Point

When the cell configures PCCCH in the case of single block access, The
counter increments after BSC database successfully assigning related
resource

Confidential and Proprietary Information of ZTE CORPORATION 531


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C61010
Definition

Number of cell attempts for uplink assignment due to response paging


Description

The counter records number of correct channel requests after receiving


the access cause, which is response paging.
Measurement Point

Definition

When the cell configures PCCCH, after receiving channel request, BSC
checks whether the cell the channel requests and the access cause are
correct. C61010 accumulates for correct channel request and the
access cause is response paging.

C61011
Definition

Number of cell successful uplink assignment due to response paging


Description

The counter records number of successful assignment after receiving


the access cause, which is response paging
Measurement Point

When the cell configures PCCCH in the case of response paging, The
counter increments after BSC database successfully assigning related
resource

C61012
Number of cell attempts for uplink assignment due to cell updating
Description

The counter records number of correct channel requests after receiving


the access cause, which is cell updating
Measurement Point

When the cell configures PCCCH, after receiving channel request, BSC
checks whether the cell the channel requests and the access cause are
correct. C61012 accumulates for correct channel request and the
access cause is cell updating.

C61013
Definition

Number of cell successful uplink assignment due to cell updating

532 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

Description

The counter records number of successful assignment after receiving


the access cause, which is cell updating
Measurement Point

When the cell configures PCCCH in the case of cell updating, the
counter increments after BSC database successfully assigning related
resource

C61014
Definition

Number of cell attempts for uplink assignment due to mobility


management
Description

The counter records number of correct channel requests after receiving


the access cause, which is mobility management
Measurement Point

When the cell configures PCCCH, after receiving channel request,


BSC checks whether the cell the channel requests and the access
cause are correct. C61014 accumulates for correct channel request
and the access cause is mobility management.

C61015
Number of cell successful uplink assignment due to mobility
management
Description

The counter records number of successful assignment after receiving


the access cause, which is mobility management
Measurement Point

When the cell configures PCCCH, after receiving channel request, BSC
checks whether the cell the channel requests and the mobility
management are correct. C61015 accumulates for correct channel
request and the access cause is mobility management.

C61016
Definition

Number of cell attempts for uplink assignment due to TWO PHASE


access
Description

The counter records number of correct channel requests after receiving


the access cause, which is TWO PHASE access.

Confidential and Proprietary Information of ZTE CORPORATION 533


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

Measurement Point

After receiving channel request, BSC checks whether the cell the
channel requests and the access cause are correct. C61016
accumulates for correct channel request and the access cause is TWO
PHASE access.

C61017
Definition

Number of cell successful uplink assignment due to TWO PHASE access


Description

The counter records number of successful assignment after receiving


the access cause, which is TWO PHASE access.
Measurement Point

When the cell configures PCCCH in the case of TWO PHASE access, The
counter increments after BSC database successfully assigning related
resource; when the cell doesn’t configure PCCCH in the case of TWO
PHASE access, The counter increments after BSC sends instant
assignment and receives message returned by BTS which is also send
to MS.

C61018
Definition

Number of cell attempts for uplink assignment due to short access


Description

The counter records number of correct channel requests after receiving


the access cause, which is short access.
Measurement Point

When the cell configures PCCCH, after receiving channel request, BSC
checks whether the cell the channel requests and the access cause are
correct. C61018 accumulates for correct channel request and the
access cause is short access.

C61019
Definition

Number of cell successful uplink assignments due to short access


Description

The counter records number of successful assignments after receiving


the access cause, which is short access.
Measurement Point

534 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

When the cell configures PCCCH, after receiving channel request, BSC
checks whether the cell the channel requests and the short access are
correct. C61019 accumulates for correct channel request and the
access cause is short access.

C61020
Definition

Number of messages in PGH-AGCH queue


Description

The counter records number of the assignment messages waiting in a


queue and will be send on PCH-AGCH.
Measurement Point

Not calculated for the time being

C61021
Definition

Number of assignment messages in PPCH-PAGCH queue


Description

The counter records number of assignment messages waiting in a


queue and will be send on PPCH-PAGCH.
Measurement Point

Not calculated for the time being

C61022
Definition

Number of paging messages deleted from PCH queue


Description

The counter records number of paging messages deleted from PCH


queue
Measurement Point

Not calculated for the time being

C61023
Definition

Number of packet paging messages deleted from PPCH queue


Description

Confidential and Proprietary Information of ZTE CORPORATION 535


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

The counter records number of packet paging messages deleted from


PPCH queue
Measurement Point

Not calculated for the time being

C61024
Definition

Number of paging messages sent unsuccessfully from cell


Description

The counter records number of paging messages send unsuccessfully


from cell
Measurement Point

Not calculated for the time being

C61025
Definition

Average number of available PDCH


Description

The counter records average Number of available PDCH


Measurement Point

Querying the database every thirty seconds to obtain the number of


configured PDCH of the cell.
Sum of available PDCHs within five minutes/number of statistics =
Average number of available PDCH
C61025 increments at the time of measurement cycle, every five
minutes.

C61026
Definition

Maximum number of available PDCH


Description

The counter records maximum number of available PDCH.


Measurement Point

C61026 increments at the time of measurement cycle, every five


minutes.

536 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 30 - Packet Switched Service Measurement

C61027
Definition

Minimum number of available PDCH


Description

The counter records minimum number of available PDCHs.


Measurement Point

C61027 increments at the time of measurement cycle, every five


minutes.

C61028
Definition

Average number of occupied PDCH


Description

The counter records average number of assigned PDCHs.


Measurement Point

C61028 increments at the time of measurement cycle, every five


minutes.

C61029
Definition

Maximum number of occupied PDCH


Description

The counter records maximum number of assigned PDCH.


Measurement Point

C61029 increments at the time of measurement cycle, every five


minutes.

C61030
Definition

Minimum number of occupied PDCH


Description

The counter records minimum number of assigned PDCH.


Measurement Point

C61030 increments at the time of measurement cycle, every five


minutes.

Confidential and Proprietary Information of ZTE CORPORATION 537


C61031
Definition

Average number of messages in PCH-AGCH queue


Description

The counter records average number of messages waiting in a queue


and will be send on PCH-AGCH.
Measurement Point

Not calculated for the time being

C61032
Definition

Average number of messages in PPCH-PAGCH queue


Description

The counter records average number of messages waiting in a queue


and will be send on PPCH-PAGCH.
Measurement Point

Not calculated for the time being.

538 Confidential and Proprietary Information of ZTE CORPORATION


Appendix A

Abbreviations

Abbreviation Full Name


A
Abis A-bis Interface
AIPP A Interface Peripheral Processor
AIU A Interface Unit
AUC Access Unit Controller
B
BAF BSS Adapter Function
BCCH Broadcast Channel
BIE Base station Interface Equipment
BIPP aBis Interface Peripheral Processor
BIU aBis Interface Unit
BOSN Bit Oriented Switching Network
BRP BSSGP RLC/MAC Protocol
BSIA Base Station Interface Adapter
BSC Base Station Controller
BSS Base station Sub System
BSSAP Base station Sub System Application Part
BSSGP Base station Sub System GPRS Protocol
BTS Base Transceiver Station
BVC BSSGP Virtual Connect
C
CBCH Cell Broadcast Channel
CCCH Common Control Channel
CDF Commands Dispatching Function
CLF Commands Logging Function
CMIP Common Management Information Protocol
CMIS Common Management Information Service

Confidential and Proprietary Information of ZTE CORPORATION 539


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter).doc

Abbreviation Full Name


CRF Commands Resolution Function
CS Circuit Switched
D
DRT Dual-Rate Transcoder
DSP Digital Signal Processor
E
EDRT Enhanced DRT
EFD Event Forwarding Discriminator
EGSM Extend GSM
ESU Executable Software Unit
F
FN Frame Number
FR Frame Relay
FRP FR Protocol
FTAM File Transfer Access Maintenance
FU Frame Unit
FUC Frame Unit Controller
G
GGSN Gateway GPRS Support Node
GIPP Gb Interface Peripheral Processor
GIU GPRS Interface Unit
GPRS General Packet Radio Service
GSM Globe System for Mobile communication
GSN GPRS Support Node
H
HMS ZXIP10-AS HMS
HSN Hopping Sequence Number
L
LAF Local Access Function
LAPD Link Access Protocol of D-Channel
LMF Local Management Function
LMT Local Management Terminal
M
MAC Medium Access Control
MAF Management Application Functions
MAIO Mobile Allocation Index Offset
MIB Management Information Base

540 Confidential and Proprietary Information of ZTE CORPORATION


Appendix A - Abbreviations

Abbreviation Full Name


MIT MO Instance Tree
MF Mediation Function
MKF MMI Kernel Function
MMI Man Machine Interface
MML Man Machine Language
MO Managed Object
MOC Managed Object Class
MOF MO administration Function
MP Main Processor
MS Mobile Station
MSC Mobile Switch Center
MSF Management Support Function
MTP Message Transfer Part
N
NAF NMC Access Function
NC Network Control
NEF Network Element Function
NMC Network Management Center
NS Network Service
NSVC NS Virtual Circuit
O
OMC Operation Maintenance Center
OMCR Operation Maintenance Center Radio
OOF Operation Outputting Function
OSF Operations Systems Function
P
PACCH Packet Associated Control Channel
PAGCH Paging & Access Granted Channel
PCU Packet Control Unit
PDCH Packet Data Channel
PDTCH Packet Data Traffic Channel
PDU Protocol Data Unit
PP Peripheral Processor
PS Packet Switched
PTM Point To Multipoint
PTP Point To Point
PUC Packet Unit Control

Confidential and Proprietary Information of ZTE CORPORATION 541


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter).doc

Abbreviation Full Name


PVC Permanent Virtual Circuit
R
RACH Random Access Channel
RMM Radio Management Module
RLC Radio Link Control
S
SDCCH Specified Control Channel
SGSN Serving GPRS Support Node
SMB Short Message Broadcast
SMM Service Management Module
SMS Short Message Service
SSF Session Services Function
T
TC TransCoder
TCH Traffic Channel
TCPP TransCoder unit Peripheral Processor
TIC Trunk Interface Circuit
TMM Transport Management Module
TMN Telecommunication Management Network
TRAU Transcoder and Rate Adaptor Unit
TRX Transceiver
U
UISF User Interface Support Function
W
WAF Windows Administration Function
WSF WorkStation Function

542 Confidential and Proprietary Information of ZTE CORPORATION


Appendix B

Tables

Table 1 chapters summary ...........................................................................xi


Table 2 Typographical Conventions .............................................................. xiii
Table 3 Mouse Operation Conventions .......................................................... xiv
Table 4 Safety Signs...................................................................................xv
Table 5 key performance indicators ............................................................... 1
Table 6 power control counters ....................................................................42
Table 7 trx service counters.........................................................................52
Table 8 Paging Measurement Counters ..........................................................75
Table 9 Counters of Carrier Frequency-Level Basic Measurement.......................75
Table 10 TRX power and Temperature counters ..............................................76
Table 11 channel measurement counters .......................................................79
Table 12 random access counters .................................................................92
Table 13 sdcch counters............................................................................ 104
Table 14 sapi 3 Counters........................................................................... 146
Table 15 rmm assignment counters ............................................................ 155
Table 16 rmm assignment queue counter .................................................... 162
Table 17 rmm call drop counters ................................................................ 163
Table 18 Handover Cause Counters ............................................................ 183
Table 19 handover counters ...................................................................... 202
Table 20 synchronized handover counters.................................................... 251
Table 21 paging message counter............................................................... 256
Table 22 abis-interface message counters.................................................... 258
Table 23 resourse availability counters ........................................................ 271
Table 24 - sub cell counters ...................................................................... 282
Table 25 bssap message counters .............................................................. 301
Table 26 bssmap message counters............................................................ 304
Table 27 smm assignment Counters ........................................................... 309
Table 28 SMM Handover Counters .............................................................. 312
Table 29 smm call drop counters ................................................................ 315
Table 30 SCCP Connection Counters ........................................................... 319
Table 31 Trunk Circuit Counters ................................................................. 322
Table 32 lapd link counters........................................................................ 326
Table 33 rmm load counters ...................................................................... 333
Table 34 service load counter .................................................................... 336
Table 35 usability measurement counter ..................................................... 337
Table 36 smm load counters ...................................................................... 338
Table 37 file system load counters.............................................................. 338
Table 38 Q3 module measurement counters ................................................ 341
Table 39 Q3 cell measurement counters ...................................................... 352
Table 40 adjacent cell handover counters .................................................... 355
Table 41 phase-3 nms counters ................................................................. 364
Table 42 tch/h measurement counters ........................................................ 381
Table 43 hr measurement counters............................................................. 409
Table 44 Counters for Reserved Channels .................................................... 435

Confidential and Proprietary Information of ZTE CORPORATION 543


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter).doc

Table 45 PS Basic Measurement Counters – Cell as the Unit ........................... 439


Table 46 Counters for PS Basic Measurement – BSC as Unit ........................... 445
Table 47 Correspondence Relationships between Bandwidth and Coding Scheme
...................................................................................................... 459
Table 48 Counters C70501~C70536 ........................................................... 482
Table 49 Traffic Statistic Counters .............................................................. 486
Table 50 Counters C60301~ C60352........................................................... 518
Table 51 NS Sub layer Counters ................................................................. 523
Table 52 BSSGP Layer Counters ................................................................. 532
Table 53 NSE Performance Counters ........................................................... 543
Table 54 Resource Management counters .................................................... 554

544 Confidential and Proprietary Information of ZTE CORPORATION


Appendix C

Figures

FIGURE 1 - power control process ...............................................................42


FIGURE 2 - intra cell handover process..........................................................55
FIGURE 3 - intra bsc handover process..........................................................56
FIGURE 4 - inter-cell handover failure process................................................59
FIGURE 5 - intra cell handover failure process ................................................60
FIGURE 6 - T8 Timeout ...............................................................................63
FIGURE 7 - random access process ...............................................................94
FIGURE 8 - sdcch assignment flow.............................................................. 103
FIGURE 9 - immediate assignment flow ....................................................... 115
FIGURE 10 - common assignment flow ........................................................ 115
FIGURE 11 - internal handover (intra-bsc handover) ..................................... 116
FIGURE 12 - external handover (intra-msc handover).................................... 116
FIGURE 13 - sapi 3 Counters measurement points ........................................ 146
FIGURE 14 - Intra-BSC Inter-cell Handover Measurement .............................. 209
FIGURE 15 - intra msc handover successes.................................................. 210
FIGURE 16 - intra msc handover fail ........................................................... 210
FIGURE 17 - Intra MSC Handover in............................................................ 214
FIGURE 18 - external handover in process (Part Flow) ................................... 265
FIGURE 19 - calculating sdcch busy time ..................................................... 275
FIGURE 20 - smm assignment process ........................................................ 309
FIGURE 21 - assignment failures Process ..................................................... 311
FIGURE 22 - handover process................................................................... 312
FIGURE 23 - Handover Failure Process ........................................................ 314
FIGURE 24 - SCCP Connection Setup .......................................................... 318
FIGURE 25 - Time Delay Scenario in SCCP Connection Setup.......................... 320
FIGURE 26 - SCCP ‘Connection Refused’ from MSC........................................ 321
FIGURE 27 - Total Busy Time for the Trunk Circuits....................................... 324
FIGURE 28 - successful intra cell handover process ....................................... 344
FIGURE 29 - intra-cells handover filure process ............................................ 345
FIGURE 30 - successful inter-cell handover process....................................... 345
FIGURE 31 - inter-cell handover failure process ............................................ 349
FIGURE 32 - immidiate assignment flow ...................................................... 379
FIGURE 33 - common assignment flow ........................................................ 379
FIGURE 34 - internal handover (intra-bsc handover) ..................................... 380
FIGURE 35 - external handover (intra-msc handover).................................... 380
FIGURE 36 - CONVERSIONS from tch/f to tch/h............................................ 430
FIGURE 37 - Calculating Time of Stale Uplink GPRS TBF Receiving Window ....... 471
FIGURE 38 - Calculating Time of Stale Downlink GPRS TBF Transmitting Window
...................................................................................................... 473

Confidential and Proprietary Information of ZTE CORPORATION 547


This page is intentionally blank.

548 Confidential and Proprietary Information of ZTE CORPORATION


Appendix D

Index
C00001 ............................... 44, 45 C00048 ............................... 55, 64
C00002 ............................... 44, 46 C00049 ............................... 55, 65
C00003 ............................... 44, 46 C00050 ............................... 55, 65
C00004 ............................... 44, 46 C00051 ............................... 55, 66
C00005 ............................... 44, 47 C00052 ............................... 55, 66
C00006 ............................... 44, 47 C00053 ............................... 55, 66
C00007 ............................... 44, 47 C00054 ............................... 55, 67
C00008 ............................... 44, 47 C00055 ............................... 55, 67
C00009 ............................... 44, 48 C00056 ............................... 55, 67
C00010 ............................... 44, 48 C00057 ............................... 55, 67
C00011 ............................... 44, 48 C00058 ............................... 55, 68
C00012 ............................... 45, 49 C00059 ............................... 55, 68
C00013 ............................... 45, 49 C00060 ............................... 55, 68
C00014 ............................... 45, 49 C00061 ............................... 55, 68
C00015 ............................... 45, 49 C00062 ............................... 55, 69
C00016 ............................... 45, 50 C00063 ............................... 55, 69
C00017 ............................... 45, 50 C00064 ............................... 56, 69
C00018 ............................... 45, 50 C00065 ............................... 56, 69
C00019 ............................... 45, 51 C00066 ............................... 56, 70
C00020 ............................... 45, 51 C00067 ............................... 56, 70
C00021 ............................... 45, 51 C00068 ............................... 56, 70
C00022 ............................... 45, 51 C00069 ............................... 56, 70
C00023 ............................... 45, 52 C00070 ............................... 56, 71
C00024 ............................... 45, 52 C00071 ............................... 56, 71
C00025 ............................... 45, 52 C00072 ............................... 56, 71
C00026 ............................... 45, 53 C00073 ............................... 56, 72
C00027 ............................... 45, 53 C00074 ............................... 56, 72
C00028 ............................... 45, 53 C00075 ............................... 56, 72
C00029 ............................... 54, 57 C00076 ............................... 56, 72
C00030 ............................... 54, 58 C00077 ............................... 56, 73
C00031 ............................... 54, 58 C00078 ............................... 56, 73
C00032 ............................... 54, 59 C00079 ............................... 56, 73
C00033 ............................... 54, 59 C00080 ............................... 56, 73
C00034 ............................... 54, 59 C00081 ............................... 56, 74
C00035 ............................... 54, 59 C00082 ............................... 56, 74
C00036 ............................... 54, 60 C00083 ............................... 56, 74
C00037 ............................... 54, 60 C00084 ............................... 56, 74
C00038 ............................... 54, 60 C00085 ............................... 56, 75
C00039 ............................... 54, 61 C00086 ............................... 56, 75
C00040 ............................... 54, 62 C00087 ............................... 57, 75
C00041 ............................... 54, 62 C00088 ............................... 57, 75
C00042 ............................... 55, 63 C00089 ............................... 57, 76
C00043 ............................... 55, 63 C00090 ............................... 57, 76
C00044 ............................... 55, 63 C00091 ............................... 57, 76
C00045 ............................... 55, 63 C00092 ............................... 57, 76
C00046 ............................... 55, 64 C01001 .....................................77
C00047 ............................... 55, 64 C01002 .....................................77

Confidential and Proprietary Information of ZTE CORPORATION 549


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C01003 .....................................77 C10202 ............................148, 150


C01004 .....................................77 C10203 ............................148, 150
C02001 ................................... 354 C10204 ............................148, 150
C02002 ................................... 354 C10205 ............................148, 150
C02003 ................................... 354 C10206 ............................148, 151
C02004 ................................... 354 C10207 ............................149, 151
C02005 ................................... 354 C10208 ............................149, 151
C02006 ................................... 354 C10209 ............................149, 152
C02007 ................................... 354 C10210 ............................149, 152
C02008 ................................... 355 C10211 ............................149, 152
C02009 ................................... 355 C10212 ............................149, 152
C02010 ................................... 355 C10213 ............................149, 153
C02011 ................................... 355 C10214 ............................149, 153
C02012 ................................... 355 C10215 ............................149, 153
C02013 ................................... 355 C10216 ............................149, 153
C02014 ................................... 355 C10217 ............................149, 153
C10001 ............................... 94, 96 C10218 ............................149, 154
C10002 ............................... 94, 96 C10219 ............................149, 154
C10003 ............................... 95, 97 C10220 ............................149, 154
C10004 ............................... 95, 97 C10221 ............................149, 154
C10005 ............................... 95, 97 C10222 ............................149, 154
C10006 ............................... 95, 98 C10223 ............................149, 155
C10007 ............................... 95, 98 C10224 ............................149, 155
C10008 ............................... 95, 98 C10225 ............................149, 155
C10009 ............................... 95, 98 C10301 ............................119, 122
C10010 ............................... 95, 99 C10302 ............................119, 122
C10011 ............................... 95, 99 C10303 ............................119, 122
C10012 ............................... 95, 99 C10304 ............................119, 123
C10013 ............................. 95, 100 C10305 ............................119, 123
C10014 ............................. 95, 100 C10306 ............................119, 123
C10015 ............................. 95, 100 C10307 ............................119, 124
C10016 ............................. 95, 101 C10308 ............................119, 124
C10017 ............................. 95, 101 C10309 ............................119, 124
C10018 ............................. 95, 101 C10310 ............................119, 125
C10019 ............................. 95, 102 C10311 ............................119, 125
C10020 ............................. 95, 102 C10312 ............................119, 125
C10021 ............................. 95, 102 C10313 ............................119, 126
C10022 ............................. 95, 102 C10314 ............................119, 126
C10023 ............................. 95, 103 C10315 ............................119, 126
C10024 ............................. 95, 103 C10316 ............................119, 127
C10025 ............................. 96, 103 C10317 ............................119, 127
C10101 ................................... 106 C10318 ............................119, 127
C10102 ............................106, 108 C10319 ............................119, 128
C10103 ............................106, 108 C10320 ............................119, 128
C10104 ............................106, 108 C10321 ............................119, 128
C10105 ............................106, 109 C10322 ............................120, 129
C10106 ............................106, 109 C10323 ............................120, 129
C10107 ............................106, 110 C10324 ............................120, 129
C10108 ............................106, 110 C10325 ............................120, 130
C10109 ............................106, 110 C10326 ............................120, 130
C10110 ............................106, 111 C10327 ............................120, 130
C10111 ............................106, 111 C10328 ............................120, 131
C10112 ............................106, 111 C10329 ............................120, 131
C10113 ............................106, 112 C10330 ............................120, 132
C10114 ............................106, 112 C10331 ............................120, 132
C10115 ............................106, 112 C10332 ............................120, 132
C10116 ............................106, 113 C10333 ............................120, 133
C10117 ............................106, 113 C10334 ............................120, 133
C10118 ............................106, 113 C10335 ............................120, 133
C10119 ............................106, 114 C10336 ............................120, 134
C10201 ............................148, 149 C10337 ............................120, 134

550 Confidential and Proprietary Information of ZTE CORPORATION


Appendix D - Index

C10338 ............................120, 134 C10430 ............................384, 395


C10339 ............................120, 135 C10431 ............................384, 396
C10340 ............................120, 135 C10432 ............................384, 396
C10341 ............................120, 136 C10433 ............................384, 396
C10342 ............................120, 136 C10434 ............................384, 397
C10343 ............................120, 136 C10435 ............................384, 397
C10344 ............................120, 137 C10436 ............................384, 397
C10345 ............................120, 137 C10437 ............................384, 398
C10346 ............................121, 137 C10438 ............................384, 398
C10347 ............................121, 138 C10439 ............................384, 399
C10348 ............................121, 138 C10440 ............................384, 399
C10349 ............................121, 138 C10441 ............................384, 399
C10350 ............................121, 139 C10442 ............................384, 400
C10351 ............................121, 139 C10443 ............................384, 400
C10352 ............................121, 139 C10444 ............................384, 400
C10353 ............................121, 140 C10445 ............................385, 401
C10354 ............................121, 140 C10446 ............................385, 401
C10355 ............................121, 140 C10447 ............................385, 401
C10356 ............................121, 141 C10448 ............................385, 402
C10357 ............................121, 141 C10449 ............................385, 402
C10358 ............................121, 141 C10450 ............................385, 403
C10359 ............................121, 142 C10451 ............................385, 403
C10360 ............................121, 142 C10452 ............................385, 403
C10361 ............................121, 142 C10453 ............................385, 403
C10362 ............................121, 143 C10454 ............................385, 404
C10363 ............................121, 143 C10455 ............................385, 404
C10364 ............................121, 143 C10456 ............................385, 404
C10365 ............................121, 144 C10457 ............................385, 405
C10366 ............................121, 144 C10458 ............................385, 405
C10367 ............................121, 144 C10459 ............................385, 405
C10368 ............................121, 145 C10460 ............................385, 406
C10369 ............................122, 145 C10461 ............................385, 406
C10401 ............................383, 386 C10462 ............................385, 406
C10402 ............................383, 386 C10463 ............................385, 407
C10403 ............................383, 386 C10464 ............................385, 407
C10404 ............................383, 387 C10465 ............................385, 407
C10405 ............................383, 387 C10466 ............................385, 408
C10406 ............................383, 387 C10467 ............................385, 408
C10407 ............................383, 388 C10468 ............................385, 408
C10408 ............................383, 388 C10469 ............................386, 409
C10409 ............................383, 388 C10470 ................................... 435
C10410 ............................383, 389 C10471 ............................435, 436
C10411 ............................383, 389 C10472 ............................435, 436
C10412 ............................383, 389 C10473 ............................435, 436
C10413 ............................383, 390 C10501 ............................157, 158
C10414 ............................383, 390 C10502 ............................157, 158
C10415 ............................383, 390 C10503 ............................157, 159
C10416 ............................383, 390 C10504 ............................157, 159
C10417 ............................383, 391 C10505 ............................157, 159
C10418 ............................383, 391 C10506 ............................157, 160
C10419 ............................383, 392 C10507 ............................158, 160
C10420 ............................383, 392 C10508 ............................158, 160
C10421 ............................383, 392 C10509 ............................158, 160
C10422 ............................384, 392 C10510 ............................158, 161
C10423 ............................384, 393 C10511 ............................158, 161
C10424 ............................384, 393 C10512 ............................158, 161
C10425 .....................384, 393, 421 C10513 ............................158, 162
C10426 ............................384, 394 C10514 ............................158, 162
C10427 ............................384, 394 C10515 ............................158, 162
C10428 ............................384, 394 C10516 ............................158, 163
C10429 ............................384, 395 C10517 ............................158, 163

Confidential and Proprietary Information of ZTE CORPORATION 551


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C10518 ............................158, 163 C10709 ............................... 82, 86


C10601 ............................165, 168 C10710 ............................... 82, 86
C10602 ............................165, 168 C10711 ............................... 82, 87
C10603 ............................165, 168 C10712 ............................... 82, 87
C10604 ............................165, 169 C10713 ............................... 82, 87
C10605 ............................165, 169 C10714 ............................... 82, 88
C10606 ............................165, 169 C10715 ............................... 82, 88
C10607 ............................166, 170 C10716 ............................... 82, 88
C10608 ............................166, 170 C10717 ............................... 82, 88
C10609 ............................166, 170 C10718 ............................... 82, 89
C10610 ............................166, 171 C10719 ............................... 82, 89
C10611 ............................166, 171 C10720 ............................... 82, 89
C10612 ............................166, 171 C10721 ............................... 82, 89
C10613 ............................166, 171 C10722 ............................... 82, 89
C10614 ............................166, 172 C10723 ............................... 82, 89
C10615 ............................166, 172 C10724 ............................... 82, 89
C10616 ............................166, 172 C10725 ............................... 82, 89
C10617 ............................166, 173 C10726 ............................... 82, 90
C10618 ............................166, 173 C10727 ............................... 82, 90
C10619 ............................166, 173 C10728 ............................... 83, 90
C10620 ............................166, 174 C10729 ............................... 83, 90
C10621 ............................166, 174 C10730 ..........................83, 90, 91
C10622 ............................166, 175 C10731 ............................... 83, 91
C10623 ............................166, 175 C10732 ............................... 83, 91
C10624 ............................166, 175 C10733 .....................................83
C10625 ............................166, 175 C10734 ............................... 83, 91
C10626 ............................166, 176 C10735 ............................... 83, 91
C10627 ............................166, 176 C10736 ............................... 83, 91
C10628 ............................166, 177 C10737 ............................... 83, 91
C10629 ............................166, 177 C10738 ............................... 83, 91
C10630 ............................167, 177 C10739 ............................... 83, 92
C10631 ............................167, 177 C10740 ............................... 83, 92
C10632 ............................167, 178 C10741 ............................... 83, 92
C10633 ............................167, 178 C10742 ............................... 83, 92
C10634 ............................167, 178 C10743 ............................... 83, 92
C10635 ............................167, 179 C10744 ............................... 83, 92
C10636 ............................167, 179 C10745 ............................... 83, 92
C10637 ............................167, 179 C10746 ............................... 83, 92
C10638 ............................167, 180 C10747 ............................... 83, 92
C10639 ............................167, 180 C10748 ............................... 83, 93
C10640 ............................167, 180 C10749 ............................... 83, 93
C10641 ............................167, 181 C10750 ............................... 83, 93
C10642 ............................167, 181 C10751 ............................... 84, 93
C10643 ............................167, 181 C10801 ............................185, 187
C10644 ............................167, 182 C10802 ............................185, 188
C10645 ............................167, 182 C10803 ............................185, 188
C10646 ............................167, 183 C10804 ............................185, 188
C10647 ............................167, 183 C10805 ............................185, 189
C10648 ............................167, 183 C10806 ............................185, 189
C10649 ............................167, 183 C10807 ............................185, 189
C10650 ............................167, 184 C10808 ............................186, 190
C10651 ............................167, 184 C10809 ............................186, 190
C10652 ............................167, 184 C10810 ............................186, 190
C10701 ............................... 81, 84 C10811 ............................186, 191
C10702 ............................... 81, 84 C10812 ............................186, 191
C10703 ............................... 81, 84 C10813 ............................186, 191
C10704 ............................... 81, 85 C10814 ............................186, 192
C10705 ............................... 82, 85 C10815 ............................186, 192
C10706 ............................... 82, 85 C10816 ............................186, 192
C10707 ............................... 82, 85 C10817 ............................186, 193
C10708 ............................... 82, 86 C10818 ............................186, 193

552 Confidential and Proprietary Information of ZTE CORPORATION


Appendix D - Index

C10819 ............................186, 193 C109121...........................209, 249


C10820 ............................186, 194 C109122...........................210, 249
C10821 ............................186, 194 C109123...........................210, 249
C10822 ............................186, 195 C109124...........................210, 249
C10823 ............................186, 195 C109125...........................210, 250
C10824 ............................186, 195 C109126...........................210, 250
C10825 ............................186, 196 C109127...........................210, 251
C10826 ............................186, 196 C109128...........................210, 251
C10827 ............................186, 196 C109129...........................210, 251
C10828 ............................186, 197 C10913 ............................205, 216
C10829 ............................186, 197 C10914 ............................205, 216
C10830 ............................187, 197 C10915 ............................205, 217
C10831 ............................187, 198 C10916 ............................205, 217
C10832 ............................187, 198 C10917 ............................205, 217
C10833 ............................187, 198 C10918 ............................205, 217
C10834 ............................187, 199 C10919 ............................205, 218
C10835 ............................187, 199 C10920 ............................205, 218
C10836 ............................187, 199 C10921 ............................205, 218
C10837 ............................187, 200 C10922 ............................205, 219
C10838 ............................187, 200 C10923 ............................205, 219
C10839 ............................187, 200 C10924 ............................205, 219
C10840 ............................187, 201 C10925 ............................205, 219
C10841 ............................187, 201 C10926 ............................205, 220
C10842 ............................187, 201 C10927 ............................205, 220
C10843 ............................187, 202 C10928 ............................205, 220
C10844 ............................187, 202 C10929 ............................205, 221
C10845 ............................187, 202 C10930 ............................206, 221
C10846 ............................187, 202 C10931 ............................206, 221
C10901 ............................204, 210 C10932 ............................206, 221
C10902 ............................204, 211 C10933 ............................206, 222
C10903 ............................204, 211 C10934 ............................206, 222
C10904 ............................204, 212 C10935 ............................206, 222
C10905 ............................204, 213 C10936 ............................206, 223
C10906 ............................204, 213 C10937 ............................206, 223
C10907 ............................205, 213 C10938 ............................206, 223
C10908 ............................205, 214 C10939 ............................206, 224
C10909 ............................205, 214 C10940 ............................206, 224
C10910 ............................205, 214 C10941 ............................206, 224
C109100...........................209, 243 C10942 ............................206, 225
C109101...........................209, 243 C10943 ............................206, 225
C109102...........................209, 243 C10944 ............................206, 225
C109103...........................209, 244 C10945 ............................206, 226
C109104...........................209, 244 C10946 ............................206, 226
C109105...........................209, 244 C10947 ............................206, 226
C109106...........................209, 244 C10948 ............................206, 226
C109107...........................209, 245 C10949 ............................206, 227
C109108...........................209, 245 C10950 ............................206, 227
C109109...........................209, 245 C10951 ............................206, 227
C10911 ............................205, 215 C10952 ............................206, 228
C109110...........................209, 245 C10953 ............................207, 228
C109111...........................209, 246 C10954 ............................207, 228
C109112...........................209, 246 C10955 ............................207, 229
C109113...........................209, 246 C10956 ............................207, 229
C109114...........................209, 247 C10957 ............................207, 229
C109115...........................209, 247 C10958 ............................207, 230
C109116...........................209, 247 C10959 ............................207, 230
C109117...........................209, 247 C10960 ............................207, 230
C109118...........................209, 248 C10961 ............................207, 231
C109119...........................209, 248 C10962 ............................207, 231
C10912 ............................205, 215 C10963 ............................207, 231
C109120...........................209, 248 C10964 ............................207, 232

Confidential and Proprietary Information of ZTE CORPORATION 553


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C10965 ............................207, 232 C11206 ............................253, 256


C10966 ............................207, 232 C11207 ............................253, 257
C10967 ............................207, 233 C11208 ............................253, 257
C10968 ............................207, 233 C11301 ................................... 258
C10969 ............................207, 233 C11401 ............................260, 262
C10970 ............................207, 234 C11402 ............................260, 262
C10971 ............................207, 234 C11403 ............................260, 262
C10972 ............................207, 234 C11404 ............................260, 262
C10973 ............................207, 235 C11405 ............................260, 263
C10974 ............................207, 235 C11406 ............................260, 263
C10975 ............................207, 235 C11407 ............................260, 263
C10976 ............................208, 236 C11408 ............................260, 264
C10977 ............................208, 236 C11409 ............................261, 264
C10978 ............................208, 236 C11410 ............................261, 264
C10979 ............................208, 237 C11411 ............................261, 265
C10980 ............................208, 237 C11412 ............................261, 265
C10981 ............................208, 237 C11413 ............................261, 265
C10982 ............................208, 238 C11414 ............................261, 265
C10983 ............................208, 238 C11415 ............................261, 266
C10984 ............................208, 238 C11416 ............................261, 266
C10985 ............................208, 238 C11417 ............................261, 266
C10986 ............................208, 239 C11418 ............................261, 267
C10987 ............................208, 239 C11419 ............................261, 267
C10988 ............................208, 239 C11420 ............................261, 268
C10989 ............................208, 240 C11421 ............................261, 269
C10990 ............................208, 240 C11422 ............................261, 269
C10991 ............................208, 240 C11423 ............................261, 269
C10992 ............................208, 241 C11424 ............................261, 270
C10993 ............................208, 241 C11425 ............................261, 270
C10994 ............................208, 241 C11426 ............................261, 270
C10995 ............................208, 241 C11427 ............................261, 270
C10996 ............................208, 242 C11428 ............................261, 271
C10997 ............................208, 242 C11429 ............................261, 271
C10998 ............................208, 242 C11430 ............................261, 271
C10999 ............................209, 242 C11431 ............................261, 272
C11001 ................................... 164 C11501 ............................273, 274
C11002 ................................... 164 C11502 ............................273, 275
C11003 ................................... 164 C11503 ............................274, 275
C11004 ................................... 164 C11504 ............................274, 275
C11005 ................................... 164 C11505 ............................274, 277
C11101 ............................357, 358 C11506 ............................274, 277
C11102 ............................357, 358 C11507 ............................274, 278
C11103 ............................357, 359 C11508 ............................274, 278
C11104 ............................357, 359 C11509 ............................274, 278
C11105 ............................357, 359 C11510 ............................274, 279
C11106 ............................357, 360 C11511 ............................274, 279
C11107 ............................357, 360 C11512 ............................274, 280
C11108 ............................357, 361 C11513 ............................274, 280
C11109 ............................357, 361 C11514 ............................274, 280
C11110 ............................357, 361 C11515 ............................274, 281
C11111 ............................357, 362 C11516 ............................274, 281
C11112 ............................358, 362 C11517 ............................274, 282
C11113 ............................358, 363 C11518 ............................274, 282
C11114 ............................358, 363 C11519 ............................274, 283
C11115 ............................358, 363 C11520 ............................274, 283
C11116 ................................... 364 C11521 ............................274, 283
C11201 ............................253, 255 C11601 ...................................1, 7
C11202 ............................253, 255 C11602 ...................................1, 7
C11203 ............................253, 255 C11603 ...................................1, 8
C11204 ............................253, 256 C11604 ...................................1, 8
C11205 ............................253, 256 C11605 ...................................1, 8

554 Confidential and Proprietary Information of ZTE CORPORATION


Appendix D - Index

C11606 ...................................2, 9 C11635 ................................. 3, 18


C11607 ...................................2, 9 C11636 ................................. 3, 18
C11608 ...................................2, 9 C11637 ................................. 3, 18
C11609 ................................. 2, 10 C11638 ................................. 3, 18
C11610 ................................. 2, 10 C11639 ................................. 3, 19
C116100................................ 6, 36 C11640 ................................. 3, 19
C116101................................ 6, 36 C11641 ................................. 3, 19
C116102................................ 6, 36 C11642 ................................. 3, 19
C116103................................ 6, 37 C11643 ................................. 3, 20
C116104................................ 6, 37 C11644 ................................. 3, 20
C116105................................ 6, 37 C11645 ................................. 3, 20
C116106................................ 6, 37 C11646 ................................. 3, 20
C116107................................ 6, 38 C11647 ................................. 3, 21
C116108................................ 6, 38 C11648 ................................. 3, 21
C116109................................ 6, 38 C11649 ................................. 3, 21
C11611 ................................. 2, 10 C11650 ................................. 3, 21
C116110................................ 6, 38 C11651 ................................. 4, 22
C116111................................ 6, 39 C11652 ................................. 4, 22
C116112................................ 6, 39 C11653 ................................. 4, 22
C116113................................ 6, 39 C11654 ................................. 4, 23
C116114................................ 6, 39 C11655 ................................. 4, 23
C116115..................................... 6 C11656 ................................. 4, 23
C116116..................................... 6 C11657 ................................. 4, 24
C116117..................................... 6 C11658 ................................. 4, 24
C116118..................................... 6 C11659 ................................. 4, 24
C116119..................................... 6 C11660 ................................. 4, 25
C11612 ................................. 2, 11 C11661 ................................. 4, 25
C116120..................................... 7 C11662 ................................. 4, 25
C116121..................................... 7 C11663 ................................. 4, 26
C116122..................................... 7 C11664 ................................. 4, 26
C116123..................................... 7 C11665 ................................. 4, 26
C116124..................................... 7 C11666 ................................. 4, 26
C116125..................................... 7 C11667 ................................. 4, 27
C116126..................................... 7 C11668 ................................. 4, 27
C116127..................................... 7 C11669 ................................. 4, 27
C116128..................................... 7 C11670 ................................. 4, 28
C116129..................................... 7 C11671 ................................. 4, 28
C11613 ................................. 2, 11 C11672 ................................. 4, 28
C116130................................ 7, 40 C11673 ................................. 4, 29
C116131................................ 7, 40 C11674 ................................. 5, 29
C11614 ................................. 2, 11 C11675 ................................. 5, 29
C11615 ................................. 2, 12 C11676 ................................. 5, 29
C11616 ................................. 2, 12 C11677 ................................. 5, 30
C11617 ................................. 2, 12 C11678 ................................. 5, 30
C11618 ................................. 2, 13 C11679 ................................. 5, 30
C11619 ................................. 2, 13 C11680 ................................. 5, 30
C11620 ................................. 2, 14 C11681 ................................. 5, 31
C11621 ................................. 2, 14 C11682 ................................. 5, 31
C11622 ................................. 2, 14 C11683 ................................. 5, 31
C11623 ................................. 2, 14 C11684 ................................. 5, 31
C11624 ................................. 2, 15 C11685 ................................. 5, 32
C11625 ................................. 2, 15 C11686 ................................. 5, 32
C11626 ................................. 2, 15 C11687 ................................. 5, 32
C11627 ................................. 2, 16 C11688 ................................. 5, 32
C11628 ................................. 3, 16 C11689 ................................. 5, 33
C11629 ................................. 3, 16 C11690 ................................. 5, 33
C11630 ................................. 3, 16 C11691 ................................. 5, 33
C11631 ................................. 3, 17 C11692 ................................. 5, 34
C11632 ................................. 3, 17 C11693 ................................. 5, 34
C11633 ................................. 3, 17 C11694 ................................. 5, 34
C11634 ................................. 3, 17 C11695 ................................. 5, 34

Confidential and Proprietary Information of ZTE CORPORATION 555


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C11696 ................................. 5, 35 C11938 ............................413, 424


C11697 ................................. 6, 35 C11939 ............................413, 424
C11698 ................................. 6, 35 C11940 ............................413, 425
C11699 ................................. 6, 36 C11941 ............................413, 425
C11715 ............................368, 378 C11942 ............................413, 425
C11801 ............................343, 344 C11943 ............................413, 425
C11802 ............................343, 344 C11944 ............................413, 426
C11803 ............................343, 346 C11945 ............................413, 426
C11804 ............................343, 346 C11946 ............................413, 426
C11805 ............................343, 347 C11947 ............................413, 426
C11806 ............................343, 348 C11948 ............................413, 427
C11807 ............................343, 348 C11949 ............................413, 427
C11808 ............................343, 348 C11950 ............................413, 427
C11809 ............................344, 349 C11951 ............................413, 427
C11810 ............................344, 349 C11952 ............................413, 428
C11811 ............................344, 349 C11953 ............................413, 428
C11812 ............................344, 350 C11954 ............................413, 428
C11813 ................................... 350 C11955 ................................... 413
C11814 ............................344, 350 C11956 ............................413, 429
C11815 ............................344, 351 C11957 ............................413, 429
C11816 ............................344, 351 C11958 ............................414, 429
C11817 ............................344, 352 C11959 ............................414, 430
C11818 ............................344, 352 C11960 ................................... 430
C11819 ............................344, 352 C11961 ............................414, 430
C11901 ............................411, 415 C11962 ............................414, 430
C11902 ............................411, 415 C11963 ............................414, 431
C11903 ............................411, 415 C11964 ............................414, 431
C11904 ............................411, 415 C11965 ............................414, 431
C11905 ............................411, 416 C11966 ............................414, 431
C11906 ............................411, 416 C11967 ............................414, 432
C11907 ............................411, 416 C11968 ............................414, 432
C11908 ............................411, 417 C11969 ............................414, 433
C11909 ............................411, 417 C11970 ............................414, 433
C11910 ............................411, 417 C11971 ............................414, 433
C11911 ............................412, 417 C11972 ............................414, 433
C11912 ............................412, 418 C11973 ............................414, 434
C11913 ............................412, 418 C12001 ............................284, 286
C11914 ............................412, 418 C12002 ............................284, 287
C11915 ............................412, 418 C12003 ............................284, 288
C11916 ............................412, 419 C12004 ............................284, 288
C11917 ............................412, 419 C12005 ............................284, 288
C11918 ............................412, 419 C12006 ............................284, 288
C11919 ............................412, 419 C12007 ............................284, 289
C11920 ............................412, 420 C12008 ............................284, 289
C11921 ............................412, 420 C12009 ............................285, 289
C11922 ............................412, 420 C12010 ............................285, 290
C11923 ............................412, 420 C12011 ............................285, 290
C11924 ............................412, 421 C12012 ............................285, 290
C11925 ................................... 412 C12013 ............................285, 291
C11926 ............................412, 421 C12014 ............................285, 291
C11927 ............................412, 421 C12015 ............................285, 291
C11928 ............................412, 422 C12016 ............................285, 292
C11929 ............................412, 422 C12017 ............................285, 292
C11930 ............................412, 422 C12018 ............................285, 292
C11931 ............................412, 422 C12019 ............................285, 293
C11932 ............................412, 423 C12020 ............................285, 293
C11933 ............................412, 423 C12021 ............................285, 293
C11934 ............................413, 423 C12022 ............................285, 294
C11935 ............................413, 423 C12023 ............................285, 294
C11936 ............................413, 424 C12024 ............................285, 294
C11937 ............................413, 424 C12025 ............................285, 295

556 Confidential and Proprietary Information of ZTE CORPORATION


Appendix D - Index

C12026 ............................285, 295 C20031 ................................... 307


C12027 ............................285, 296 C20032 ................................... 307
C12028 ............................285, 296 C20033 ................................... 307
C12029 ............................285, 297 C20034 ................................... 307
C12030 ............................285, 297 C20035 ................................... 307
C12031 ............................285, 297 C20036 ................................... 307
C12032 ............................286, 298 C20037 ................................... 307
C12033 ............................286, 298 C20038 ................................... 307
C12034 ............................286, 298 C20039 ................................... 307
C12035 ............................286, 299 C20040 ................................... 307
C12036 ............................286, 299 C20041 ................................... 308
C12037 ............................286, 299 C20042 ................................... 308
C12038 ............................286, 299 C20043 ................................... 308
C12039 ............................286, 300 C20044 ................................... 308
C12040 ............................286, 300 C20045 ................................... 308
C12041 ............................286, 300 C20046 ................................... 308
C12042 ............................286, 301 C20047 ................................... 308
C12043 ............................286, 301 C20048 ................................... 308
C12044 ............................286, 301 C20049 ................................... 308
C12045 ............................286, 302 C20050 ................................... 308
C12046 ............................286, 302 C20051 ................................... 308
C13001 .....................................77 C20052 ................................... 308
C13002 .....................................77 C20053 ................................... 308
C13003 .....................................77 C20054 ................................... 308
C13004 .....................................77 C20065 ................................... 308
C14001 .....................................78 C20066 ................................... 308
C14002 .....................................78 C20101 ............................303, 304
C14003 ............................... 78, 79 C20102 ............................303, 304
C14004 ............................... 78, 79 C20103 ............................303, 304
C14005 ............................... 78, 79 C20104 ............................304, 305
C14006 ............................... 78, 79 C20105 ............................304, 305
C20001 ................................... 306 C20201 ................................... 321
C20002 ................................... 306 C20202 ................................... 321
C20003 ................................... 306 C20203 ............................321, 322
C20004 ................................... 306 C20204 ............................321, 322
C20005 ................................... 306 C20205 ............................321, 323
C20006 ................................... 306 C20206 ............................321, 323
C20007 ................................... 306 C20301 ................................... 311
C20008 ................................... 306 C20302 ................................... 311
C20009 ................................... 306 C20303 ............................311, 312
C20010 ................................... 306 C20304 ............................311, 312
C20011 ................................... 306 C20305 ............................311, 313
C20012 ................................... 306 C20401 ................................... 314
C20013 ................................... 306 C20402 ................................... 315
C20014 ................................... 306 C20403 ................................... 315
C20015 ................................... 306 C20404 ................................... 315
C20016 ................................... 306 C20405 ................................... 316
C20017 ................................... 306 C20501 ................................... 317
C20018 ................................... 306 C20502 ................................... 317
C20019 ................................... 307 C20503 ............................317, 318
C20020 ................................... 307 C20504 ............................317, 318
C20021 ................................... 307 C20601 ................................... 324
C20022 ................................... 307 C20602 ............................324, 325
C20023 ................................... 307 C20603 ............................324, 325
C20024 ................................... 307 C20604 ............................324, 325
C20025 ................................... 307 C20605 ............................324, 326
C20026 ................................... 307 C30001 ............................328, 330
C20027 ................................... 307 C30002 ............................328, 330
C20028 ................................... 307 C30003 ............................328, 330
C20029 ................................... 307 C30004 ............................328, 331
C20030 ................................... 307 C30005 ............................328, 331

Confidential and Proprietary Information of ZTE CORPORATION 557


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C30006 ............................328, 331 C51028 ............................535, 542


C30007 ............................328, 332 C51029 ............................535, 543
C30008 ............................328, 332 C51030 ............................535, 543
C30009 ............................330, 332 C51031 ............................535, 543
C30010 ............................330, 332 C51032 ............................535, 543
C30011 ............................330, 333 C52001 ............................544, 545
C30012 ............................330, 333 C52002 ............................544, 546
C30013 ............................330, 333 C52003 ............................544, 546
C50001 ............................524, 526 C52004 ............................544, 546
C50002 ............................524, 526 C52005 ............................544, 547
C50003 ............................524, 526 C52006 ............................544, 547
C50004 ............................525, 526 C52007 ............................544, 548
C50005 ............................525, 527 C52008 ............................544, 548
C50006 ............................525, 527 C52009 ............................544, 548
C50007 ............................525, 527 C52010 ............................544, 548
C50008 ............................525, 527 C52011 ............................544, 549
C50009 ............................525, 528 C52012 ............................544, 549
C50010 ............................525, 528 C52013 ............................544, 549
C50011 ............................525, 528 C52014 ............................544, 550
C50012 ............................525, 529 C52015 ............................544, 550
C50013 ............................525, 529 C52016 ............................545, 550
C50014 ............................525, 529 C52017 ............................545, 550
C50015 ............................525, 529 C52018 ............................545, 551
C50016 ............................525, 530 C52019 ............................545, 551
C50017 ............................525, 530 C52020 ............................545, 551
C50018 ............................525, 530 C52021 ................................... 545
C50019 ............................525, 530 C52022 ............................545, 552
C50020 ............................525, 531 C52023 ............................545, 552
C50021 ............................525, 531 C52024 ............................545, 552
C50022 ............................525, 531 C52025 ............................545, 553
C50023 ............................525, 532 C52026 ............................545, 553
C50024 ............................525, 532 C52027 ............................545, 553
C50025 ............................525, 532 C52028 ............................545, 554
C50026 ............................526, 532 C52029 ............................545, 554
C51001 ............................533, 535 C52030 ................................... 545
C51002 ............................533, 535 C52031 ............................545, 554
C51003 ............................533, 536 C52032 ............................545, 555
C51004 ............................533, 536 C60001 ............................486, 490
C51005 ............................533, 536 C60002 ............................486, 491
C51006 ............................533, 536 C60003 ............................486, 491
C51007 ............................533, 537 C60004 ............................486, 491
C51008 ............................533, 537 C60005 ............................486, 492
C51009 ............................533, 537 C60006 ............................487, 492
C51010 ............................533, 537 C60007 ............................487, 492
C51011 ............................534, 538 C60008 ............................487, 492
C51012 ............................534, 538 C60009 ............................487, 493
C51013 ............................534, 538 C60010 ............................487, 493
C51014 ............................534, 539 C60011 ............................487, 493
C51015 ............................534, 539 C60012 ............................487, 493
C51016 ............................534, 539 C60013 ............................487, 494
C51017 ............................534, 539 C60014 ............................487, 494
C51018 ............................534, 540 C60015 ............................487, 494
C51019 ............................534, 540 C60016 ............................487, 495
C51020 ............................534, 540 C60017 ............................487, 495
C51021 ............................534, 540 C60018 ............................487, 495
C51022 ............................534, 541 C60019 ............................487, 495
C51023 ............................534, 541 C60020 ............................487, 496
C51024 ............................534, 541 C60021 ............................487, 496
C51025 ............................534, 542 C60022 ............................487, 496
C51026 ............................534, 542 C60023 ............................487, 496
C51027 ............................535, 542 C60024 ............................487, 497

558 Confidential and Proprietary Information of ZTE CORPORATION


Appendix D - Index

C60025 ............................487, 497 C60086 ............................490, 515


C60026 ............................487, 497 C60087 ............................490, 515
C60027 ............................487, 498 C60088 ............................490, 516
C60028 ............................487, 498 C60089 ............................490, 516
C60029 ............................488, 498 C60090 ............................490, 516
C60030 ............................488, 498 C60091 ............................490, 516
C60031 ............................488, 499 C60092 ............................490, 517
C60032 ............................488, 499 C60093 ............................490, 517
C60033 ............................488, 499 C60094 ............................490, 517
C60034 ............................488, 499 C60095 ............................490, 518
C60035 ............................488, 500 C60301 ................................... 518
C60036 ............................488, 500 C60302 ................................... 518
C60037 ............................488, 500 C60303 ................................... 518
C60038 ............................488, 501 C60304 ................................... 518
C60039 ............................488, 501 C60305 ................................... 518
C60040 ............................488, 501 C60306 ................................... 519
C60041 ............................488, 502 C60307 ................................... 519
C60042 ............................488, 502 C60308 ................................... 519
C60043 ............................488, 502 C60309 ................................... 519
C60044 ............................488, 502 C60310 ................................... 519
C60045 ............................488, 503 C60311 ................................... 519
C60046 ............................488, 503 C60312 ................................... 519
C60047 ............................488, 503 C60313 ................................... 519
C60048 ............................488, 504 C60314 ................................... 519
C60049 ............................488, 504 C60315 ................................... 520
C60050 ............................488, 504 C60316 ................................... 520
C60051 ............................488, 505 C60317 ................................... 520
C60052 ............................489, 505 C60318 ................................... 520
C60053 ............................489, 505 C60319 ................................... 520
C60054 ............................489, 506 C60320 ................................... 520
C60055 ............................489, 506 C60321 ................................... 520
C60056 ............................489, 506 C60322 ................................... 520
C60057 ............................489, 507 C60323 ................................... 520
C60058 ............................489, 507 C60324 ................................... 521
C60059 ............................489, 507 C60325 ................................... 521
C60060 ............................489, 507 C60326 ................................... 521
C60061 ............................489, 508 C60327 ................................... 521
C60062 ............................489, 508 C60328 ................................... 521
C60063 ............................489, 508 C60329 ................................... 521
C60064 ............................489, 508 C60330 ................................... 521
C60065 ............................489, 509 C60331 ................................... 521
C60066 ............................489, 509 C60332 ................................... 521
C60067 ............................489, 509 C60333 ................................... 522
C60068 ............................489, 510 C60334 ................................... 522
C60069 ............................489, 510 C60335 ................................... 522
C60070 ............................489, 510 C60336 ................................... 522
C60071 ............................489, 510 C60337 ................................... 522
C60072 ............................489, 511 C60338 ................................... 522
C60073 ............................489, 511 C60339 ................................... 522
C60074 ............................489, 511 C60340 ................................... 522
C60075 ............................489, 512 C60341 ................................... 523
C60076 ............................490, 512 C60342 ................................... 523
C60077 ............................490, 512 C60343 ................................... 523
C60078 ............................490, 513 C60344 ................................... 523
C60079 ............................490, 513 C60345 ................................... 523
C60080 ............................490, 513 C60346 ................................... 523
C60081 ............................490, 513 C60347 ................................... 523
C60082 ............................490, 514 C60348 ................................... 523
C60083 ............................490, 514 C60349 ................................... 524
C60084 ............................490, 514 C60350 ................................... 524
C60085 ............................490, 515 C60351 ................................... 524

Confidential and Proprietary Information of ZTE CORPORATION 559


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C60352 ................................... 524 C70029 ............................441, 453


C61001 ............................555, 557 C70030 ............................441, 453
C61002 ............................555, 557 C70031 ............................441, 453
C61003 ............................555, 557 C70032 ............................441, 454
C61004 ............................555, 557 C70033 ............................441, 454
C61005 ............................555, 558 C70034 ............................441, 454
C61006 ............................555, 558 C70035 ............................441, 454
C61007 ............................555, 558 C70036 ............................441, 455
C61008 ............................555, 559 C70037 ............................441, 455
C61009 ............................555, 559 C70038 ............................441, 455
C61010 ............................555, 559 C70039 ............................441, 456
C61011 ............................555, 560 C70040 ............................441, 456
C61012 ............................555, 560 C70041 ............................441, 456
C61013 ............................556, 560 C70042 ............................441, 456
C61014 ............................556, 560 C70043 ............................441, 457
C61015 ............................556, 561 C70044 ............................441, 457
C61016 ............................556, 561 C70045 ............................441, 457
C61017 ............................556, 561 C70046 ............................441, 458
C61018 ............................556, 562 C70047 ............................441, 458
C61019 ............................556, 562 C70048 ............................442, 458
C61020 ............................556, 562 C70049 ............................442, 459
C61021 ............................556, 563 C70050 ............................442, 459
C61022 ............................556, 563 C70051 ............................442, 459
C61023 ............................556, 563 C70052 ............................442, 460
C61024 ............................556, 563 C70053 ............................442, 460
C61025 ............................556, 564 C70054 ............................442, 460
C61026 ............................556, 564 C70055 ............................442, 461
C61027 ............................556, 564 C70056 ............................442, 461
C61028 ............................556, 564 C70057 ............................442, 461
C61029 ............................556, 565 C70058 ............................442, 461
C61030 ............................556, 565 C70059 ............................442, 462
C61031 ............................556, 565 C70060 ............................442, 462
C61032 ............................556, 565 C70061 ............................442, 462
C70001 ............................439, 445 C70062 ............................442, 463
C70002 ............................439, 446 C70063 ............................442, 463
C70003 ............................440, 446 C70064 ............................442, 463
C70004 ............................440, 446 C70065 ............................442, 464
C70005 ............................440, 446 C70066 ............................442, 464
C70006 ............................440, 447 C70067 ............................442, 464
C70007 ............................440, 447 C70068 ............................442, 464
C70008 ............................440, 447 C70069 ............................442, 465
C70009 ............................440, 448 C70070 ............................442, 465
C70010 .....................440, 448, 450 C70071 ............................443, 465
C70011 ............................440, 448 C70072 ............................443, 465
C70012 ............................440, 448 C70073 ............................443, 466
C70013 ............................440, 449 C70074 ............................443, 466
C70014 ............................440, 449 C70075 ............................443, 466
C70015 ............................440, 449 C70076 ............................443, 467
C70016 ............................440, 449 C70077 ............................443, 467
C70017 ............................440, 450 C70078 ............................443, 467
C70018 ............................440, 450 C70079 ............................443, 468
C70019 ................................... 440 C70080 ............................443, 468
C70020 ............................440, 450 C70081 ............................443, 468
C70021 ............................440, 451 C70082 ............................443, 468
C70022 ............................440, 451 C70083 ............................443, 469
C70023 ............................440, 451 C70084 ............................443, 469
C70024 ............................440, 451 C70085 ............................443, 469
C70025 ............................440, 452 C70086 ............................443, 470
C70026 ............................441, 452 C70087 ............................443, 470
C70027 ............................441, 452 C70088 ............................443, 470
C70028 ............................441, 453 C70089 ............................443, 471

560 Confidential and Proprietary Information of ZTE CORPORATION


Appendix D - Index

C70090 ............................443, 471 C70530 ................................... 484


C70091 ............................443, 472 C70531 ................................... 484
C70092 ............................443, 473 C70532 ................................... 484
C70093 ............................444, 473 C70533 ................................... 484
C70094 ............................444, 474 C70534 ................................... 484
C70095 ............................444, 474 C70535 ................................... 484
C70096 ............................444, 474 C70536 ................................... 484
C70097 ............................444, 475 C80001 ............................366, 368
C70098 ............................444, 475 C80002 .......................... 366, 368
C70099 ............................444, 475 C80003 .......................... 366, 368
C70100 ............................444, 476 C80004 ................................. 366
C70101 ............................444, 476 C80005 .......................... 366, 369
C70102 ............................444, 476 C80006 .......................... 366, 369
C70103 ............................444, 476 C80007 .......................... 366, 369
C70104 ............................444, 477 C80008 .......................... 366, 369
C70105 ............................444, 477 C80009 .......................... 367, 370
C70106 ............................444, 477 C80010 .......................... 367, 370
C70107 ............................444, 478 C80011 .......................... 367, 370
C70108 ............................444, 478 C80012 .......................... 367, 371
C70109 ............................444, 478 C80013 .......................... 367, 371
C70110 ............................444, 478 C80014 .......................... 367, 371
C70111 ............................444, 479 C80015 .......................... 367, 371
C70112 ............................444, 479 C80016 .......................... 367, 372
C70113 ............................444, 479 C80017 .......................... 367, 372
C70114 ............................444, 479 C80018 .......................... 367, 372
C70115 ............................444, 480 C80019 .......................... 367, 373
C70116 ............................445, 480 C80020 .......................... 367, 373
C70117 ............................445, 480 C80021 .......................... 367, 373
C70118 ............................445, 480 C80022 ............................367, 373
C70119 ............................445, 481 C80023 ............................367, 374
C70120 ............................445, 481 C80024 ............................367, 374
C70121 ............................445, 481 C80025 ............................367, 374
C70501 ................................... 482 C80026 ............................367, 374
C70502 ................................... 482 C80027 ............................367, 375
C70503 ................................... 482 C80028 ............................367, 375
C70504 ................................... 482 C80029 ............................367, 375
C70505 ................................... 482 C80030 ............................367, 376
C70506 ................................... 482 C80031 ............................367, 376
C70507 ................................... 482 C80032 ............................367, 376
C70508 ................................... 482 C80033 ............................367, 376
C70509 ................................... 482 C80034 ............................368, 377
C70510 ................................... 482 C80035 ............................368, 377
C70511 ................................... 482 C80036 ............................368, 377
C70512 ................................... 482 C80037 ............................368, 377
C70513 ................................... 483 C80038 ............................368, 378
C70514 ................................... 483 C80039 ............................368, 378
C70515 ................................... 483 C8004 ..................................... 368
C70516 ................................... 483 C80040 ............................368, 378
C70517 ................................... 483 C90001 ................................... 445
C70518 ................................... 483 C90002 ................................... 445
C70519 ................................... 483 C90003 ................................... 445
C70520 ................................... 483 C90004 ................................... 445
C70521 ................................... 483 C90005 ................................... 445
C70522 ................................... 483 C90006 ................................... 445
C70523 ................................... 483 C90007 ................................... 445
C70524 ................................... 483 C90101 ............................335, 337
C70525 ................................... 483 C90102 ............................335, 337
C70526 ................................... 484 C90103 ............................335, 337
C70527 ................................... 484 C90104 ............................335, 338
C70528 ................................... 484 C90201 ................................... 338
C70529 ................................... 484 C90301 ................................... 339

Confidential and Proprietary Information of ZTE CORPORATION 561


ZXG10-BSS(V2.95) Base Station Subsystem Operation Manual (Performance Measurement Counter)

C90401 ................................... 340 C90505 ................................... 340


C90402 ................................... 340 C90506 ................................... 340
C90403 ................................... 340 C90507 ................................... 340
C90404 ................................... 340 C90508 ................................... 340
C90501 ................................... 340 C90509 ................................... 340
C90502 ................................... 340 C90510 ................................... 341
C90503 ................................... 340 C90511 ................................... 341
C90504 ................................... 340

562 Confidential and Proprietary Information of ZTE CORPORATION

Vous aimerez peut-être aussi