Académique Documents
Professionnel Documents
Culture Documents
Lot 42, Jalan Merbau Pulas, No.9-1 & 9-2, Jalan Puteri 5/20, Bandar Puteri,
Kawasan Perindustrian Kuala Ketil, 47100 Puchong, Selangor
09300 Kuala Ketil, Baling, Kedah MALAYSIA
MALAYSIA Tel : +603-80601222, +603-8061112, +603-
Tel : +604-4161600 Fax : +604-4161599 80601100
Website : www.southerncable.cc Fax : +603-80601212
Email : sc@southerncable.cc Website : www.southerncable.cc
SOUTHERN CABLE offers an Aluminum rods as one product in usage for wires and cables industry. The
Aluminum rods are consumed internally as well as being supplied locally and internationally.
9.5 mm
INGOTS FURNACE CASTING HOT-ROLLED
ALUMINUM RODS SOUTHERN CABLE
Diameter Tolerance
Specified Deviation of Mean Diameter from Deviation at any point from Specified
Diameter Specified Diameter (mm) Diameter (mm)
9.52 ± 0.51 ± 0.76
Electrical Properties
Temper Min. Electrical Conductivity % Max. Resistivity (Ω.mm2/m)
1350-0 61.8 0.027899
1350-H12 61.5 0.028035
1350-H14 61.4 0.028080
1350-H16 61.3 0.028126
Chemical Compositions
Element Compositions (%)
Silicon (Max.) 0.10
Iron (Max.) 0.40
Copper (Max.) 0.05
Manganese (Max.) 0.01
Chromium (Max.) 0.01
Zinc (Max.) 0.05
Boron (Max.) 0.05
Gallium (Max.) 0.03
Vanadium (Max.) 0.02
Other Elements, each (Max.) 0.03
Other Elements, total (Max.) 0.10
Aluminum (Min.) 99.50
http://www.southerncable.cc
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however,
should independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an
assurance is only provided in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale.
ALUMINUM RODS SOUTHERN CABLE
Weight 30 329
Resistance 164 61
Area 329 30
Diameter 180 55
Weight 50 200
Area 164 61
Diameter 128 78
Weight 50 200
Weight 42 237
Diameter 119 84
http://www.southerncable.cc
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however,
should independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an
assurance is only provided in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale.
COPPER RODS
Specifications
ASTM : B 49
Diamater Tolerance
Diameter
mm mm
8 ± 0.38
Round Rod
12.5 ± 0.38
Table 2: Characteristic
Elongation % Min: 30
Conductivity % IACS 100
Resistivity at 20˚ C µΩ .m Max: 0.017241
Density g/cm³ 8.89
Oxygen Content (min) ppm Max: 10
Element Composition
Copper 99.95%
http://www.southerncable.cc
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief
correct and reliable. Users, however, should independently evaluate the suitability of each product for the desired application. Under no circumstances does this
constitute an assurance of any particular quality or performance. Such an assurance is only provided in the context of our product specifications or explicit
contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale.
Southern Cable offers a comprehensive range of copper conductor as compenant of earthing or
structual lighting protection system. The product of High Conductivity Coper Tape is produced
to BS EN 13601 (formerly BS 1432). Refer to the following details specification.
Standard / Specification
The following stadards and specification shall be applied
BS EN 13601:2002
No Description Unit Requirement
1 TOLERANCE ON DIMENSIONS AND SHAPE
Thickness and Width
1.1 Nominal Thickness (y) mm 3 ± 0.03
1.2 Nominal Width (x) mm 25 ± 0.10
1.3 TEMPER SOFT
2 MECHANICAL PROPERTIES
2.2 Tensile Strength N/m² min: 210, max: 250
3 Elongation % > 35
3.1 CHEMICAL COMPOSITION AND MATERIAL
3.2 Copper % > 99.95
3.3 Silver % (for copper plus silver)
3.2 Bismuth % < 0.0010
4 Lead % < 0.005
5 ELECTRICAL CONDUCTIVITY at 20°C % IACS > 100
EMBOSSING
SOUTHERN BS EN 13601
6 PACKING kg/coil 55 ± 5
http://www.southerncable.cc
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users,
however, should independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance.
Such an assurance is only provided in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of
sale.
BARE COPPER WIRE SOUTHERN CABLE
Application
Stranded bare copper conductors are suitable for overhead transmission and distribution
applications.
Specifications : BS 7884
http://www.southerncable.cc
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and
reliable. Users, however, should independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of
any particular quality or performance. Such an assurance is only provided in the context of our product specifications or explicit contractual arrangements. Our liability for these
products is set forth in our standard terms and conditions of sale.
BARE COPPER WIRE SOUTHERN CABLE
COPPER WIRE
Application
Copper Wire
Specifications : BS 7884
Physical, mechanical and electrical properties of solid, circular, hard drawn copper wire
Nominal area of Wire diameter Nominal Minimum
Resistance at 20°C
cross-section Nominal Max Min mass per breaking
mm² mm mm mm length
kg/km Ω/km Ω/km load
N
1.43 1.35 1.364 1.337 12.73 12.41 12.66 583
2.01 1.60 1.616 1.584 17.87 8.838 9.018 818
2.27 1.70 1.717 1.683 20.18 7.829 7.988 923
2.54 1.80 1.818 1.782 22.62 6.983 7.125 1035
3.46 2.10 2.121 2.079 30.79 5.130 5.235 1409
3.98 2.25 2.273 2.228 35.35 4.469 4.558 1618
4.75 2.46 2.484 2.435 42.25 3.739 3.816 1932
4.91 2.50 2.525 2.475 43.64 3.620 3.694 1997
5.51 2.65 2.677 2.624 49.03 3.222 3.286 2244
6.16 2.80 2.828 2.772 54.74 2.886 2.944 2505
6.61 2.90 2.929 2.871 58.72 2.690 2.745 2687
7.07 3.00 3.030 2.970 62.84 2.514 2.565 2875
8.04 3.20 3.232 3.168 71.50 2.210 2.254 3271
9.90 3.55 3.586 3.515 87.99 1.795 1.831 4027
11.04 3.75 3.788 3.713 98.19 1.609 1.641 4494
14.52 4.30 4.350 4.250 129.10 1.224 1.253 5675
NOTE: Resistance values are calculated from a resistivity of 0.01777 µΩ.m at 20°C. This is equivalent to a conductivity of 97% IACS. Maximum values
of resistance
NOTE: are calcyulated
Minimum from
breaking loads forminimum diameters up to and including 4mm are based on the minimum dia meter of conductor and a tensile
nominal diameters
strength of 415 N/mm² and for nominal diameters greater than 4mm they are based on the minimum diameter of conductor and a tensile strength
NOTE: Nominal mass per unit length has been calculated using a density of 8890 kg/m³
http://www.southerncable.cc
All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users,
however, should independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or
performance. Such an assurance is only provided in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard
terms and conditions of sale.