Vous êtes sur la page 1sur 3

CELL VOLUME-AVERAGE TEMPERATURE AT DIFFERENT COOLANT-INFLOW

60 TEMPERATURES@0.10kgs FLOW-RATE
Circulation specifications
-Flow rate over single cell:0.10 kgs
-3.0m pressure head
56

52 40℃

48
Temperature (℃)

44
30℃
40
25℃
36
20℃
32

28
10℃
24

20
0 100 200 300 400 500 600 700 800 900
Time (s)
CELL VOLUME-AVERAGE TEMPERATURE AT DIFFERENT COOLANT INFLOW-
60 TEMPERATURES@0.075kgs FLOW-RATE
Circulation specifications
-Flow rate over single cell:0.075 kgs
-2.8m pressure head
56

52 40℃

48
Temperature(℃)

44 30℃

40 25℃

36
20℃
32

28
10℃
24

20
0 100 200 300 400 500 600 700 800 900
Time (s)
CELL VOLUME-AVERAGE TEMPERATURE AT DIFFERENT COOLANT INFLOW
60 TEMPERATURES@0.05kgs FLOW-RATE
Circulation specifications
-Flow rate over single cell:0.050 kgs
-2.6m pressure head
56

52 40℃

48
Temperature (℃)

44 30℃

40 25℃

36 20℃

32

28 10℃

24

20
0 100 200 300 400 500 600 700 800 900
Time (s)