Show the difference between the fire hose cabinet and the fire -14
? department connection
What is the required flow rate to calculate the fire pump in case -15
of the existence of fire hose cabinet and fire department
?connection
?What are the allowed pipes used for the firefighting network -21
Clarify the types of the firefighting pumps and how to conduct -22
.them with electricity
What are the suggested Firefighting systems for the following -25
(Diesel tank - hotel corridor - UPS room - main control room - hotel
guest room - pump rooms - generator room - kitchen including
)hood
Mention the types of the water closed chairs and the structural -1
.requirements for each
What are the suitable diameters for the following ( sink- bede- -5
?) chair
? What are the types of the pipes used in the drainage system -6
What is the number of the water buoys needed for two drainage -8
?pumps and what is the mechanism of the work
mm pipe 2% slope 75 -1
Which of the following pipes can be used with hot water and -10
:why
CPVC pipes -3
UPVC pipes -4
Copper pipes -5
Identify the water hammer arrestor and the regulations of its -13
. installation
.Identify Enthalpy -7
Compare between the package unit system and the chilled -10
water system and mention the buildings in which we can use both
?of them and why
Identify the VRV system and mention the advantages and -11
.disadvantages of it
Mention the types of the compressors used in the A/C systems. -12
And in which system
Sensible load = 2.50 ton - CFM discharge = 1200 CFM), Which of the
:? following unit should be used
Unit (1) - Total load = 2.5 ton - Sensible load = 2.5 ton - 1300 CFM
Unit (2) - Total load = 3.5 ton - Sensible load = * ton - 1100 CFM
Which of the following Ducts is more efficient and why? And -15
what are its disadvantages? 1- 50x50 2- 20x125 3-70x35
Mention the types of insulation for the pipes and what are the -17
?requirements to demand the insulation process
What are the required points to be ready for preparing the A/C -18
? grills
What are the required conditions distributing the feed fans and -19
?the exhaust fans on the deck
Why should we use primary pump and secondary pump in the -20
?chilled water system
When should we install the expansion tank in the cold water -21
?circle
What is the usage of the expansion tank in the cold water circle -22
?and the water feeding circle
What are the ways of reducing the vibration caused by the -23
?chillers on deck
What are the required dimensions when installing the following -24
?
Interior A/C wall unit -1
Chiller on deck -3
Flow meter -4
Flow meter -5