Sl No Description Of Item Unit Total Qty Rate Amount

Erection
A 800 kV EQUIPMENT (Fault level 40kA/1Sec)
1.0 765 kV Current Transformer (1-Phase)

a) 3000A, 40KA with 120% extended current rating Nos. 12 25,000.00 300,000.00

2.0 765 kV Capacitive Voltage Transformer (1-Phase) -

a) 8800 pF Nos. 6 25,000.00 150,000.00

765kV Isolator (3-phase) (DOUBLE BREAK/VERTICAL


3.0 KNEE TYPE) including supervision from Original -
Equipment Manufacturer

a) 3150A, 40KA, isolator with one E/S Sets 11 32,000.00 352,000.00


b) 3150A, 40KA, isolator with two E/S Sets 2 33,000.00 66,000.00
c) 3150A, 40KA, isolator without E/S Sets 2 31,000.00 62,000.00

765kV Isolator (1-phase) (DOUBLE BREAK/VERTICAL


4.0 KNEE TYPE) including supervision from Original -
Equipment Manufacturer

a) 2000A , 40 KA, isolator with one E/S Sets 9 15,000.00 135,000.00


b) 2000A , 40 KA, isolator without E/S Sets 18 14,000.00 252,000.00
5.0 624 KV Surge Arrester (1-phase) -
a) 624 KV Surge Arrester (1-phase) Nos. 21 21,000.00 441,000.00
6.0 765 KV BPI (excluding BPI for wave trap ) Nos. 74 4,500.00 333,000.00
765kV Circuit Breakers (3-Phase) with support
7.0 structure including supervision from Original -
Equipment Manufacturer
3150A, 40kA (With PIR & With Control Switching
i) Sets 3 85,000.00 255,000.00
device)
3150A, 40kA (Without PIR & With Control
ii) Sets 1 85,000.00 85,000.00
Switching device)
B 420 kV EQUIPMENT (Fault level 40kA/1Sec) -
420kV Circuit Breakers (3-Phase) with support
1.0 structure including supervision from Original -
Equipment Manufacturer
3150A, 40KA (Without PIR & With Control Switching
a) Set 1 27,000.00 27,000.00
device)
2.0 420 kV Current Transformer (1-Phase) -

a) 3000A, 40KA with 120% extended current rating Nos. 3 19,000.00 57,000.00

4.0 ISOLATORS -
4.1 420kV Isolator (3-phase) (Double Break) including -
supervision from Original Equipment Manufacturer

a) 3150A, 40KA, isolator with one E/S Nos. 1 22,000.00 22,000.00

4.1 420kV Isolator (1-phase) (Double Break) including -


supervision from Original Equipment Manufacturer

a) 3150A, 40KA, isolator with one E/S Nos. 3 9,000.00 27,000.00


b) 3150A, 40KA, isolator without E/S Nos. 3 9,000.00 27,000.00
5.0 336 KV Surge Arrester (1-phase) Nos. 3 1,200.00 3,600.00

6.0 420 kV Bus Post Insulator (excluding Wave Trap) Nos. 21 3,000.00 63,000.00

7.0 Control Switching device for Siemens Make Existing No. 1 15,000.00 15,000.00
400kV CB (Without PIR)

C 145kV Circuit Breaker (1-Phase) with support Set 2 15,000.00 30,000.00


structure for NGR By pass scheme
D RELAY & PROTECTION SYSTEM -
RELAY PANELS (WITH AUTOMATION) -
1.0 765 kV System -
1.1 Circuit Breaker Relay Panel -
a) With Auto Reclose Nos. 3 6,500.00 19,500.00
b) Without Auto Reclose Nos. 1 6,500.00 6,500.00
1.2 Line Protection Panel Nos. 2 6,500.00 13,000.00

1.3 Transformer Protection Panel (For both HV & MV Nos. 1 6,500.00 6,500.00
side)
1.4 Reactor Protection Panel Nos. 2 6,500.00 13,000.00
Augmentation of existing bus bar protection scheme
1.5 for the 765kV bays under present scope as per Set 1 35,000.00 35,000.00
technical specification
2.0 400 kV System -
2.1 Circuit Breaker Relay Panel 6,000.00 -
a) Without Auto Reclose Nos. 1 6,000.00 6,000.00
Augmentation of existing bus bar protection scheme
2.2 for the 400kV bays under present scope as per Set 1 25,000.00 25,000.00
technical specification
E SUBSTATION AUTOMATION SYSTEM -
Augmention of existing Substation automation
1.0 system as per technical Specification for the bays -
covered under present scope :
a) 800kV System -
i) Main bays Nos. 2 18,000.00 36,000.00
i) Tie bays Nos. 1 18,000.00 18,000.00
Interfacing of the relays under present scope with
existing SAS including updation of system database,
2.0 displays, development of additional displays & Set 1 28,000.00 28,000.00
reports and upgradation of hardware and software
etc as per requirement for completion of the work
under present scope :

F PLCC Equipments -
1.1 Line Traps -
a) 765kV, 3150A, 1.0 mH, 40 kA line trap Nos. 4 32,000.00 128,000.00
b) BPIs for the above line trap Nos. 12 4,500.00 54,000.00
1.2 Coupling device Nos. 2 3,500.00 7,000.00

1.3 Carrier Equipment (for speech+protection and for Nos. 5 750.00 3,750.00
speech+Data)
1.4 Protection Coupler Nos. 4 750.00 3,000.00
G Illumination System -

Lighting fixtures and Receptacles including junction


box, lighting wires& flexible conduit (if required)
1.0 from junction box to lighting fixture, mounting -
arrangement and other accessories/materials etc. as
required for complete installation and commissoning
of lighting fixture.

a) lighting Fixture Type-SF1 Nos. 45 650.00 29,250.00


b) lighting Fixture Type-SF2 Nos. 45 650.00 29,250.00
c) Outdoor Lighting Panel (Type ACP-2) Nos. 4 3,500.00 14,000.00
High Beam fixtures on swivel support (Type-SF4) as
c) Nos. 8 800.00 6,400.00
per technical specification
H) Air Conditioning system -

a) Air Conditioning system for switchyard panel room Set 1 -

I) Steel Structure -

Erection of following steel structures including nuts,


bolts, all type of washers, packplates, step bolts and -
gusset plates excluding foundation bolts

1.1 Lattice Structure for 400kV Towers & Beams MT 5,500.00 -


a) TA Nos. 6 -
b) TC Nos. 1 -
c) TI Nos. 11 -
d) TK Nos. 1 -
e) G2 Nos. 15 -
1.2 Pipe Structure for 400kV Equipments MT 5,000.00 -
a) Isolator (3-Phase) (Set of Six structures) Nos. 1 -
b) Isolator (1-Phase) (Set of two structures) Nos. 6 -
c) CT (1-Phase) Nos. 3 -
d) LA (1-Phase) Nos. 3 -
e) BPI (1-Phase) Nos. 21 -
1.3 Lattice Structure for 800kV Towers & Beams MT 6,500.00 -
a) 7CB Nos. 12 -
b) 7BC Nos. 6 -
c) 7BD Nos. 12 -
d) GWCB Nos. 12 -
e) 7CC Nos. 4 -
f) 7BE Nos. 2 -
g) 7BF Nos. 4 -
h) GWCC Nos. 4 -
1.4 Lattice Structures for 800kV Equipments MT 5,500.00 -
a) CT (1-Phase) Nos. 12 -
b) CVT (1-Phase) Nos. 6 -
c) Isolator (3-Phase) (Set of Six structures) Nos. 15 -
d) Isolator (1-Phase) (Set of two structures) Nos. 27 -
e) LA (1-Phase) Nos. 21 -
f) BPI (1-Phase) Nos. 74 -
g) Wave Trap (1-Phase) (Set of three structures) Sets 4 -
1.5 Foundation bolts MT 5,000.00 -
a) 28 mm Dia Nos. 192 -
b) 32 mm dia Nos. 3156 -
c) 40 mm Dia Nos. 216 -
d) 80 mm Dia Nos. 256 -
Dismantling of existing 400kV equipments
J) assocaited with FSC installation and handing over to -
POWERGRID at site stores
a) 400kV Isolator Nos. 6 18,000.00 108,000.00
b) 400kV BPI Nos. 216 2,500.00 540,000.00
c) 400kV LA Nos. 6 11,000.00 66,000.00
Part-II: VENDOR ASSESSED QUANTITIES -
800kV Erection Hardware (Item description as per
A Annexure-IX of Section-Project of technical -
Specification) :
765kV I-type layout Drg require
a) Line bay Set 1 35,000.00 35,000.00

b) Feeder extension on existing half dia (for 765kV line ) Set 1 30,000.00 30,000.00

c) Line Reactors including NGR By pass arrangment Set 2 35,000.00 70,000.00

d) Transformer bay Set 1 30,000.00 30,000.00


e) Bus Work (For one diameters) Set 1 45,000.00 45,000.00
420kV Erection Hardware (Item description as per
B Annexure-IX of Section-Project of technical -
Specification) :
400kV I-type layout -
Feeder extension on existing half dia (for 765/400kV
a) Sets 1 25,000.00 25,000.00
ICT as per layout)
Fire Protection System (Item description as per
C Annexure-IX of Section-Project of technical Qty require
Specification)

1.1 HVW spray system & Hydrant system for Transformer -


/ Reactor :
a) 500MVA , 765/√3 kV 1-phase Auto-Transformer Nos. 3 650,000.00 1,950,000.00
b) 80 MVAR, 765/√3 kV 1-phase Line reactor No. 6 525,000.00 3,150,000.00
c) Fire alram system for switchyard panel room Set 1 -

d) 4.5 kg CO2 type Portable extinguishers for No 1 -


Switchyard panel room
D Power & Control Cables -
1.0 1.1 kV Grade power and control cables Qty require
1.1 Power Cables (XLPE insulated) LS 1 -
1.2 Power Cable (PVC insulated) LS 1 -
1.3 Control Cable (PVC insulated) LS 1 -

1.4 Cable glands, lugs & straight through joints for above LS 1 -
Power & Control cables
E HF cable LS 1 -
Visual monitoring system for watch & ward of
F LS 1 -
extension area as per technical specification
G Illumination System -
1.0 Illumination system for switchyard panel room Set 1 -
Works related to Operation of Existing FSC at 765kV
H -
Voltage level.

Erection hardware items such as 765kV Line


breaking insulators (polymer type), Clamp &
connectors including equipment connectors,
1.0 conductors, spacers, Al tube, bus bar material, LS 1 -
earthing material, risers, cable trays & covers, PVC
pipes, cable supporting angles/chanels etc required
for completion of scope as per specification.

Necessary wiring & cabling for integration of existing


2.0 control & protection of FSC with 765kV Koteshwar LS 1 -
lines as per specification
Miscellaneous works such as Jumper connections,
3.0 Change in CT location on FSC plateform and LS 1 -
Capacitor unit conection etc required for completion
of scope as per specification.

9,232,750.00
Sl No Description Of Item Unit Total Qty Rate Qty

Erection
A 800kV Equipment (Fault level 40kA/1Sec)
800KV GIS Equipment (Module description as
A1 per Annexure-IX of Section-Project of Technical
Specification)
1.1 800kV, SF6 GIS Line feeder bay Module
For CB With PIR & Without Control switching
a) Set 2 575,000.00 1,150,000.00
device

1.2 800kV, SF6 GIS Transformer feeder bay Module -

For CB Without PIR & With Control switching


a) Set 4 575,000.00 2,300,000.00
device

1.3 800kV, SF6 GIS Bus Reactor feeder bay Module -

For CB Without PIR & With Control switching


a) Set 1 575,000.00 575,000.00
device
1.4 800kV, SF6 GIS Tie bay Module -
For CB with PIR & with Control switching
a) Set 2 570,000.00 1,140,000.00
device
For CB without PIR & with Control switching
b) Set 2 570,000.00 1,140,000.00
device
1.5 800kV, SF6 GIS Bus Bar Module Set 2 570,000.00 1,140,000.00
A2 800KV Outdoor Equipment -

800kV, 3150A, 1-Phase GIS Bus duct complete


1.1 with support structure and all assocaited RM 500 11,000.00 5,500,000.00
materils as per technical specification

800kV, 2000A, 1-Phase GIS Bus duct complete


1.2 with support structure and all assocaited RM 2500 11,000.00 27,500,000.00
materils as per technical specification

1.3 800kV, 3150A, 1-Phase GIS Bushing (SF6 to Air Nos 6 17,000.00 102,000.00
type) for 765KV lines

1.4 800kV, 2000A, 1-Phase GIS Bushing (SF6 to Oil Nos 12 18,000.00 216,000.00
type) for 765/400kV Autotransformers

1.5 800kV, 2000A, 1-Phase GIS Bushing (SF6 to Oil Nos 3 18,000.00 54,000.00
type) for 765kV Bus Reactors
1.6 624 KV Surge Arrester (1-phase) Nos. 6 16,000.00 96,000.00
1.7 765 kV CVT (1-Phase, 8800pF) Nos. 6 17,000.00 102,000.00
1.8 765 KV BPI (excluding BPI for wave trap ) Nos. 6 4,000.00 24,000.00

B) 420 kV EQUIPMENT (Fault level 40kA/1Sec) -

420KV GIS Equipment (Module description as


B1 per Annexure-IX of Section-Project of Technical -
Specification)
1.1 420kV, SF6 GIS Line feeder bay Module -
For CB Without PIR & Without Control
a) Set 1 350,000.00 350,000.00
switching device

1.2 420kV, SF6 GIS Transformer feeder bay Module -

a) For CB Without PIR & With Control switching Set 2 350,000.00 700,000.00
device
1.4 420kV, SF6 GIS Conversion bay Module -

a) With control switching device for existing CB Set 2 18,000.00 36,000.00

420kV, SF6 GIS Bus Bar Module for extension of


1.6 existing bus bars for the 400kV bays under Set 2 350,000.00 700,000.00
present scope
B2 420KV Outdoor Equipment -

420kV, 3150A, 1-Phase GIS Bus duct complete


1.1 with support structure and all assocaited RM 330 7,500.00 2,475,000.00
materials as per technical specification

420kV, 2000A, 1-Phase GIS Bus duct complete


1.2 with support structure and all assocaited RM 1170 7,500.00 8,775,000.00
materials as per technical specification

1.3 420kV, 3150A, 1-Phase GIS Bushing (SF6 to Air Nos 3 12,000.00 36,000.00
type) for 400KV line

1.4 420kV, 2000A, 1-Phase GIS Bushing (SF6 to Oil Nos 12 12,000.00 144,000.00
type) for 765/400kV Autotransformers
1.5 336 KV Surge Arrester (1-phase) Nos. 3 12,000.00 36,000.00
1.6 420 kV CVT (1- Phase, 4400pF) Nos. 3 13,000.00 39,000.00
1.7 420 KV BPI (excluding BPI for wave trap ) Nos. 3 3,000.00 9,000.00
C Testing & Maintenance Equipment for GIS -
1.1 Partial Discharge Monitoring System Set 1 25,000.00 25,000.00
1.2 EOT crane for 800 kV GIS Hall Set 1 -
D RELAY & PROTECTION SYSTEM -
RELAY PANELS (WITH AUTOMATION) -
1.0 800kV System -
1.1 Circuit Breaker Relay Panel -
a) CB Relay Panel With Auto Reclose Nos. 4 7,500.00 30,000.00
b) CB Relay Panel With out Auto Reclose Nos. 7 7,500.00 52,500.00
1.2 Line Protection Panel Nos. 2 7,500.00 15,000.00
1.3 Transformer Protection Panel (For both HV & Nos. 4 7,500.00 30,000.00
MV side)
1.4 Reactor Protection Panel No. 1 7,500.00 7,500.00
1.5 Bus Bar Protection Panel -
a) 765kV (Duplicate Bus Bar Protection) Set 1 8,000.00 8,000.00
2.0 420kV System -
2.1 Circuit Breaker Relay Panel -
a) CB Relay Panel With Auto Reclose Nos. 1 6,500.00 6,500.00
b) CB Relay Panel With out Auto Reclose Nos. 2 6,500.00 13,000.00
2.2 Line Protection Panel Nos. 1 6,500.00 6,500.00

Augmentation of existing Bus Bar Protection


2.3 scsheme for 400kV bays covered under present Set 1 45,000.00 45,000.00
scope as per technical specification

E SUBSTATION AUTOMATION SYSTEM 35,000.00 -

Augmention of existing Substation automation


1.0 system as per technical Specification for the -
bays covered under present scope :

a) 800kV System -
i) Main bays Nos. 7 30,000.00 210,000.00
ii) Tie bays Nos. 4 30,000.00 120,000.00
b) 420kV System 25,000.00 -
i) Main bays Nos. 3 25,000.00 75,000.00

Interfacing of the relays under present scope


with existing SAS including updation of system
database, displays, development of additional
2.0 displays & reports and upgradation of Set 1 18,000.00 18,000.00
hardware and software etc as per requirement
for completion of the work under present
scope:

F PLCC Equipments -
1.0 At Koteshwar End -
1.1 Line Traps -
a) 765kV, 3150A, 1.0 mH, 40 kA line trap Nos. 4 25,000.00 100,000.00
b) BPIs for the above line trap Nos. 12 4,000.00 48,000.00
c) 400kV, 3150A, 1.0 mH, 40 kA line trap Nos. 2 19,000.00 38,000.00
d) BPIs for the above line trap Nos. 6 3,000.00 18,000.00
1.2 Coupling device Nos. 3 3,500.00 10,500.00

1.3 Carrier Equipment (for speech+protection and Nos. 7 750.00 5,250.00


for speech+Data)
1.4 Protection Coupler Nos. 6 750.00 4,500.00
2.0 At TEHRI (THDC) End -
2.1 Coupling device Nos. 1 3,500.00 3,500.00
2.2 Carrier Equipment (for speech+protection and Nos. 2 750.00 1,500.00
for speech+Data)
2.3 Protection Coupler Nos. 2 750.00 1,500.00
G LT Switchgear -

1.1 415V ACDB Extension as per technical Set 1 32,000.00 32,000.00


specification
H Diesel Generator with control Panel -
a) 500 kVA Set 1 125,000.00 125,000.00
High Beam fixtures on swivel support (Type-
I Nos. 8 850.00 6,800.00
SF4) as per technical specification
J Main Earth Mat -

a) 40 mm MS rod for Main Earthmat in outdoor Km 16 150,000.00 2,400,000.00


switchayard
K Steel Structure -

Erection of following steel structures


including nuts, bolts, all type of washers,
-
packplates, step bolts and gusset plates
excluding foundation bolts

1.1 Lattice Structure for 400kV Towers & Beams MT 6,500.00 -

a) T2 (Matching with existing) Nos. 1 -


b) G1 (Matching with existing) Nos. 1 -
c) Lighting Mast (40Mtr Height) Nos. 6 -
1.2 Pipe Structure for 400kV Equipments -

a) Wave Trap (1-Phase) (Set of three structures) Sets 2 -

b) CVT (1-Phase) Nos. 3 -


c) LA (1-Phase) Nos. 3 -
d) BPI (1-Phase) Nos. 3 -
1.3 Lattice Structures for 800kV Equipments -

a) Wave Trap (1-Phase) (Set of three structures) Sets 4 -

b) CVT (1-Phase) Nos. 6 -


c) LA (1-Phase) Nos. 6 -
d) BPI (1-Phase) Nos. 6 -
1.4 Foundation bolts -
a) 28 mm Dia Nos. 72 -
b) 32 mm dia Nos. 504 -
c) 56 mm Dia Nos. 112 -

Dismantling of existing 400kV equipments


L) assocaited with Koteshwar-Meerut lines and MT 5,500.00 -
handing over to POWERGRID at site stores

a) 400kV Wave Trap (1-Phase) Nos. 4 -


b) 400kV LA (1-Phase) Nos. 6 -
c) 400kV CVT (1-Phase) Nos. 6 -
Dismantling of existing 250 kVA DG set &
d) Set 1 -
handing over to PGCIL at site stores

Dismantling of spare line protection relays &


auxilliary relays from the existing 400 kV line
e) Set 1 -
protection panel (2 nos.) & handing over to
PGCIL at stores
PART-II: VENDOR ASSESSED QUANTITIES -
800kV Erection Hardware (Item description as
A per Annexure-IX of Section-Project of technical -
Specification) :
1.1 Line Bay Module Set 2 35,000.00 70,000.00
1.2 Bus Reactor Bay Module Set 1 35,000.00 35,000.00
1.3 Transformer Bay Module Set 4 35,000.00 140,000.00
420kV Erection Hardware (Item description as
B per Annexure-IX of Section-Project of technical -
Specification) :
2.1 Line Bay Module Set 1 25,000.00 25,000.00
2.2 Transformer Bay Module Set 2 25,000.00 50,000.00
2.3 Conversion bay Module Set 2 25,000.00 50,000.00
Visual monitoring system for watch & ward as
C LS 1 -
per technical specification
D Air conditioning & Ventilation System -
1.0 Air conditioning system -
1.1 Local control room in 765kV GIS Hall LS 1 -

1.2 Local control room in 400kV GIS Hall (extension LS 1 -


area)
2.0 Ventilation system -
2.1 800KV GIS hall LS 1 -
2.2 420KV GIS hall (extension area) LS 1 -
Fire Protection System (Item description as per
E Annexure-IX of Section-Project of technical -
Specification)

1.1 HVW spray system & Hydrant system for -


Transformer / Reactor :

a) 267MVA , 765/√3 kV 1-phase Auto-Transformer Set 12 775,000.00 9,300,000.00

b) 80 MVAR, 765/√3 kV 1-phase bus reactor Set 3 680,000.00 2,040,000.00

1.2 Hydrant system outside the Pump House for Set 1 -


765kV GIS buldings

1.3 Hydrant system outside the Pump House for Set 1 -


400kV GIS building (extension area)

1.4 Smoke detection system for 765kV GIS building Set 1 -


1.5 Smoke detection system for 400kV GIS building Set 1 -
(extension area)
1.6 Fire Alarm System for 765kV GIS building Set 1 -

1.7 Fire Alarm System for 400kV GIS building Set 1 -


(extension area)

1.8 Portable Extinguishers for 765kV GIS buildings Set 1 -

1.9 Portable Extinguishers for 400kV GIS building Set 1 -


(extension area)

F Illumination System Drg require -

1.1 800kV GIS Building Set 1 -


1.2 400kV GIS Building (extension area ) Set 1 -
1.3 Outdoor Lighting -
a) Switchyard lighting LS 1 -
b) Street lighting LS 1 -

1.4 Outdoor Receptacle (250amp, TPN MCCB Set 2 -


Type )

Occupancy sensors (12 nos.) and other


1.5 accessories as required for control of Lighting Set 1 -
in the GIS Building as per specification

G Power & Control Cables -


1.0 1.1 kV Grade power and control cables -
1.1 Power Cables (XLPE insulated) LS Qty require
1.2 Power Cable (PVC insulated) LS 1 -
1.3 Control Cable (PVC insulated) LS 1 -

1.4 Cable glands, lugs & straight through joints for LS 1 -


above Power & Control cables
H HF cable -
a) At Koteshwar Pooling station LS 1 -
b) At TEHRI (THDC) station LS 1 -
69,505,550.00