Académique Documents
Professionnel Documents
Culture Documents
4
[l i
.H
r/J
A -— J-»,
\ ik
rjpjs i
r
F
Ceiling Cassette
Compact Type
(600x600)
• Compact Design
• Fresh Air Intake
• Stylish & Slim Panel FWF-C
• Built In High Head Drain Oump & Water Flow Switch
• 4 Way Air Discharge & Air Swing
• Valve Or Valveless Control Options
• Branch Duct Connection
9
eOc
• Sleep Function For Cool & Heat Mode §sc
• Auto Restart With Last-State-Memory Q
QOG
- Q
• NIM-Able
• Self Diagnosis Features
Wireless Remote Controller Wired Remote Controller
• Choices Of Wired Or Withless Remote Controller BRC52A BRC51A (Option)
48
Compact Design Branch Duct Connection
Ceiling Cassette C Series body dimension is only 570 Improves air flow distribution when there is an
mm x 570 mm which can easily fits into a 600 mm obstruction. It allows for air conditioning of two rooms
ceiling grid. simultaneously.
[
600mmÿgÿ 60Qmm
Branch duct chamber
i
Discharge
570mmÿ-
* \
Room 2
s
Heating mode* Cooling mode
u
The unit comes with a 700 mm built-in high head drain
pump. A safety float is incorporated int he drain pump
to monitor its water level. :E;PR6WII t
Setting stored before power failure.
700mm
€ IS '
ZH.
-
PACKING DIMENSION ( ) PANEL H X WX D mm 316 X 630 X 630 (126 X 700 X 726)
UNIT WEIGHT (UNIT + PANEL) kg 15 + 3 17 + 3 17 + 3
CONDENSATE DRAIN SIZE mm 19.05
PIPE CONNECTION mm 19.05 BSP FEMALE THREAD ADAPTOR
TYPE TURBO FAN
DRIVE DIRECT
FAN HIGH RPM 725 810 900
L FAN SPEED MEDIUM RPM 565 630 700
z
=> LOW RPM 460 480 610
a.
o
O TYPE INDUCTION
Q
z INDEX OF PROTECTION (IP) IP20
INSULATION GRADE B
HIGH W 63 64 79
RATED
MEDIUM W 51 58 73
INPUT POWER
LOW W 46 52 69
FAN MOTOR
HIGH A 0.28 0.28 0.35
RATED
RUNNING MEDIUM A 0.23 0.25 0.32
CURRENT LOW A 0.21 0.24 0.31
STARTING CURRENT A 0.32 0.30 0.47
MOTOR OUTPUT W 17 23 28
POLES 6
MATERIAL COPPER
TUBE
DIAMETER mm 7.00
MATERIAL ALUMINIUM
COIL
FIN FACE AREA m2 0.24 0.25 0.25
ROW 1 2 2
ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
r,
I'U
Ceiling Cassette
Type (9oox9oo)
• Multi Comfort - 3 Air Swing Pattern Control
• Fresh Air Intake
• Optimum Air Discharge
• Superior Sound Level
• Branch Duct Connection
• Low Height Design
omj]
• Built In High Head Drain Pump & Water Flow Switch
• Modern & Elegant Panel
P-I
• Low water Pressure Drop
• Self Diagnosis Features I I
• NIM-Able
• Valve Or Valveless Control Options
- '
51
-
Multi Comfort 3 Air Swing Pattern Control
To increase the comfort level of the air conditioned
Optimum Air Discharge
Combining 4 ways air discharge and large discharge
area of FWK-E series, the system had been built in area on each side, Ceiling Cassette promote even air
with three different type of air flow pattern to suit distribution. The additional feature of automatic air
different requirement. swing helps to distribute the conditioned air more
* The default setting is pattern 1. The air swing pattern can be evenly to every corner of the room.
selected via wireless remonote control.
Standard Setting
Louver is set to swing at the maximum angle for gentle drafts.
w a
10° 10:
65y
Pattern 1 65°
Superior Sound Level
With the adapted technology from Daikin turbo fan,
Ceiling Cassette series is able to achieve exceptional
low noise.
Draft Prevention Setting With up to 4 selected fan speeds, users are given
With the aid of Coanda effect, direct draft which may lead to more choices. By selecting the Quiet mode, the sound
discomfort can be avoided. pressure level can be as low as 23dBA.
V
Soil Prevention Setting Longitudinal vortices generated along serration edges accelerate
Even distribution of cooling whilst ensuring ceiling to be mixing turbulence which reduces vortex shedding noise.
kept spotless.
i
Low Height Design
Unit height as low as 265mm for installation
convenience.
Intake duct
(Field supplied and installed)
I. 265mm 350mm
i
Built In High Head Drain Pump Sleep Function For Cool And Heat Mode
& Flow Switch Once activated, set temperature will be increased /
The unit comes with a 700mm built-in high head drain decreased gradually according to normal sleeping
pump. A safety float is incorporated int he drain pump temperature patterns to ensure a comfortable sleeping
to monitor its water level. environment.
.SleepSetOn
0 1/2 !
2
700mm
I
r
i imV
Modern & Elegant Panel
It is designed with unique "round" side contour and
new LED light location. The rotateable intake grill
promotes uniform installation as well.
Heating mode* -,
+1 c
I
\
L r
9 2 §
Cooling mode
u IE? PROM'
“ ft. ’
NIM-Able Sec
Able to communicate with the versatile NIM csO
networking control module and offers the oppurtunity
of one centralized control for a system of multiple
Wireless Remote Controller Wired Remote Controller
indoor units in a building.
BRC52A BRC51A
Chilled-Water Fan Coil Unit
ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
t
w
i
4• -i r
i t
M IIi I II
m
i
a. r?
\
i h H
r
f 'J
I
H
i
lr. =» *ÿ«=“
Ceiling Cassette
Type
With Brushless DC Motor
• Comfortable
• Energy Saving
• Low Noise
• Low Maintenance & No Brush Sparking
• 4 Pipe System Available*
• Modulating Fan Speed Control
• Optimum Air Discharge
L« FWKE-E
U
• Multi Comfort - 3 Air Swing Pattern Control
• Branch Duct Connection
H "** fi,
• Low Height Design fiCt L*J
• Built In High Head Drain Pump & Water Flow Switch SSC -i-wi
• Superior Sound Level gag
• Fresh Air Intake
• Low Water Pressure Drop Wireless Remote Controller Wired Remote Controller
• Sleep Function For Cool And Heat Mode BRC52A BRC51A (Option)
• Choices Of Wired Or Withless Remote Controller
55
Energy Saving Low Noise
Compared to the traditional AC motor, DC motor offers Due to no brushes or a mechnical
the advantages of lower power input , higher commutator, it has less shaft friction
efficiency and hence more energy saving. or inertia and hence less audible
noise as low as 16 dBA.
• Brushless DC motor has less internal resistance
and better heat dissipation in the stator coils. As a
result, it has higher operating efficiencies since heat Low Maintenance & No Brush Sparking
can more efficiently dissipate via the stationary Brushless DC motor does not use carbon brushes or
motor housing. a mechanical commutator, thus, it is low maintenance
and non-sparking.
• With the green building and development being so
welcomed now, this Ceiling Casstte type with
Brushless DC motor gives you another excellent 4 Pipe System Available*
option to consider. 4 pipe system allows a distribution system that
contains both hot water supply with return lines and a
Power Consumption Comparison Between chilled-water supply with return lines.
AC Motor & DC Motor * FWKE-EH model
200]
§L 150
Modulating Fan Speed Control
100 Fan speed modulates steplessly based on room
o 50 temperature to reduce the difference between room
temperature and set temperature and hence provides
0 maximum comfort and reduces energy consumption.
600 650 700 750 800 850 900 950 1000 1050 1100
Air Flow (CFM)
* Available in auto fan mode
<4
>1
Cl u, I
£ 2
67%
CD
u. 5 I
I-
¥ £
CFM
Recommended Applications
Ceiling Cassette type fan coil with Brushless DC motor provides a green and pleasant environment.
W
U 1, '
r
Home Office Restaurant
Chilled-Water Fan Coil Unit
NOMINAL HEATING CAPACITY Btu/h 11300 15200 19800 24200 18400 23900 30400 38200 24100 31600 39100 46700
(ENTERING WATER TEMP. = 50°C) W 3300 4450 5800 7100 5400 7000 8900 11200 7050 9250 11450 13700
FAN INPUT POWER W 7 12 19 37 17 26 50 90 23 39 83 120
NOMINAL RUNNING CURRENT A 0.11 0.13 0.19 0.26 0.19 0.28 0.43 0.74 0.21 0.35 0.55 0.95
AIR FLOW CFM 220 350 470 620 420 560 720 890 510 680 870 1060
-
UNIT DIMENSION ( ) WITH PANEL HXWXD mm 265 X 820 X 820 (340 X 990 X 990) 300 X 820 X 820 (375 X 990 X 990)
-
PACKING DIMENSION ( ) PANEL HXWXD mm 341 X 916 X 916 (125 X 1020 X 1020) 376 X 916 X 916 (125 X 1020 X 1020)
UNIT WEIGHT kg 26 + 4 28 + 4 32 + 4
MATERIAL ALUMINUM
COIL
FIN FACE AREA m2 0.39 0.37 0.46
ROW 2 3 3
NOTE:
A) BASED ON EUROVENT CONDITIONS
B) ADDITIONAL 10W IS REQUIRED FOR CONDENSATE DRAIN PUMP
C) SOUND PRESSURE LEVEL IS TESTED AS PER JIS STANDARD AS BELOW:
-
FWKE05E MODEL 1.4M BELOW THE FACE CENTER OF AIR RETURN OF THE UNIT
-
FWKE08/11E MODEL 1.5M BELOW THE FACE CENTER OF AIR RETURN OF THE UNIT
MODE COOLING HEATING
ENTERING AIR TEMPERATURE 27°C DB / 19‘C WB 20‘C DB
7°C 50°C (2 Pipes System)
ENTERING WATER TEMPERATURE
70°C Pipes System)
(4
ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
B
Chilled-Water Fan Coil Unit
-
UNIT DIMENSION ( ) WITH PANEL H X WXD mm 265 X 820 X 820 (340 X 990 X 990) 300 X 820 X 820 (375 X 990 X 990)
-
PACKING DIMENSION ( ) PANEL H X WXD mm 341 X 916 X 916 (125 X 1020 X 1020) 376 X 916 X 916 (125 X 1020 X 1020)
UNIT WEIGHT kg 26 + 4 28 + 4 32 + 4
CONDENSATE DRAIN SIZE mm 19.05
b
z PIPE CONNECTION mm 19.05 BSP FEMALE THREAD ADAPTOR
Z)
a: TURBO FAN
O TYPE
o
o FAN DRIVE DIRECT
z
FAN SPEED RPM 200 280 360 450 350 440 550 660 400 510 630 750
TYPE BLDC
INDEX OF PROTECTION (IP) IP20 IP20 IP20
INSULATION GRADE E E E
FAN
MOTOR RATED RUNNING CURRENT A 0.11 0.13 0.19 0.26 0.19 0.28 0.43 0.74 0.21 0.35 0.55 0.95
STARTING CURRENT A 1.5 2.2 2.2
MOTOR OUTPUT W 70 70 100
POLES 8 8 8
MATERIAL COPPER
TUBE
DIAMETER mm 7.00
MATERIAL ALUMINUM
COIL
FIN FACE AREA m2 0.39 0.37 0.46
ROW 2 3 3
WATER VOLUME Litre 1.36 1.97 2.35
NOTE:
A) BASED ON EUROVENT CONDITIONS
B) ADDITIONAL 10W IS REQUIRED FOR CONDENSATE DRAIN PUMP
C) SOUND PRESSURE LEVEL IS TESTED AS PER JIS STANDARD AS BELOW:
-
FWKE05EH MODEL 1.4M BELOW THE FACE CENTER OF AIR RETURN OF THE UNIT
-
FWKE08/11EH MODEL 1.5M BELOW THE FACE CENTER OF AIR RETURN OF THE UNIT
MODE COOLING HEATING
ENTERING AIR TEMPERATURE 27°C DB / 19°C WB 20‘C DB
7°C 50°C (2 Pipes System)
ENTERING WATER TEMPERATURE
70°C Pipes System)
(4
ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.