Académique Documents
Professionnel Documents
Culture Documents
AD 2000
Lauterbach Verfahrenstechnik
GmbH
1 / 2011
Contents
Working with a single module in pressure vessel design 3
Introduction ................................................................................................................................ 3
Input of design data.................................................................................................................... 3
Selection of material................................................................................................................... 4
Calculation ................................................................................................................................. 6
Back calculation ......................................................................................................................... 8
Parameter study......................................................................................................................... 8
ii • Introduction AD 2000
Working with a single module
in pressure vessel design
Introduction
As a matter of principle, the modules of the field of stress calculation have a similar range of functions
and a similar appearance. However, these modules have been expanded by the option "Material" in
the "Module" menu. To get to know this option start the program AD B1.
Example:
After input of "Outside diameter" and
"Final wall thickness" the "Inside
diameter" and the "Ratio Da/Di" can be
calculated (as shown in the picture).
AD 2000 Introduction • 3
Selection of material
In the menu "Module" select
the option "Material".
Regulation AD W1
Product Blech
Spec. No. EN 10028-2
Material cod 1.0425
Click the line showing your material and confirm with OK to display a detailed documentation of
material including material coefficients and comments from the corresponding regulations.
To find out why the wall thickness sB has not been calculated click the corresponding field. Under
"Options" and "Ask for variable" or with a right mouse click, all dependent variables are highlighted in blue!
6 • Calculation AD 2000
In this case just enter the joint efficiency factor. Then the missing data can be calculated.
AD 2000 Calculation • 7
Back calculation
As you know, after input of data the missing values are calculated.
For example, enter the required wall thickness with a fixed value. The program is able to calculate
back to another value:
The previous input value for "Outside diameter Da" is overwritten by the calculated value.
Parameter study
With the option "Parameter study" in the "Atlas" menu you can determine the effects of one resp. two
values on a third value. In this example a 3-dimensional parameter study is done. Find detailed
information in the ATLAS manual.
In this cylinder there is a nozzle with an outside diameter of 114.3 mm. This opening has to be defined
with AD B9.