Boyle P>Patm

Date 5/11/2017 Your name Tam Section 1 Seat # 13


Lab partner Aimy 16

Measurements on the equipment Value Unit Note


Volume of the syringe 50.0 mL
Lengths and readings from the pipette
- Length form connection point to the first graduation line 10.30 cm
- Length form the first graduation line to the last graduation line 15.10 cm
- Length form the last graduation line to the tip 2.70 cm
- Reading at the first graduation line on the pipette -0.40 mL
- Reading at last graduation line on the pipette 1.80 mL not used
Air temperature 25.0 OC not used
Water temperature 25.5 OC
Density of water 996.68 kg/m^3 interpolation
Acceleration due to gravity 9.807 m/s^2
Pipette's cross-sectional area 0.146 cm^2
Volume adjustment 1.90 mL

water-air interface reading/mL V^-1 / m^-3 P/Pascal


outside inside (x-axis) (y-axis) x^2 y^2 xy
1.60 1.70 1.866E+04 6.709E+01 3.481E+08 4.501E+03 1.252E+06
1.40 1.68 1.866E+04 1.878E+02 3.483E+08 3.528E+04 3.506E+06
1.20 1.64 1.868E+04 2.952E+02 3.488E+08 8.713E+04 5.513E+06
1.00 1.60 1.869E+04 4.025E+02 3.494E+08 1.620E+05 7.524E+06
0.80 1.56 1.871E+04 5.099E+02 3.499E+08 2.600E+05 9.537E+06
0.60 1.52 1.872E+04 6.172E+02 3.504E+08 3.809E+05 1.155E+07
0.80 1.58 1.870E+04 5.233E+02 3.496E+08 2.738E+05 9.784E+06
1.00 1.64 1.868E+04 4.294E+02 3.488E+08 1.843E+05 8.019E+06
1.20 1.70 1.866E+04 3.354E+02 3.481E+08 1.125E+05 6.258E+06
1.40 1.75 1.864E+04 2.348E+02 3.474E+08 5.513E+04 4.376E+06
1.60 1.79 1.863E+04 1.275E+02 3.469E+08 1.625E+04 2.374E+06
SUM 2.054E+05 3.730E+03 3.836E+09 1.572E+06 6.970E+07
Average 1.867E+04 3.391E+02 3.487E+08 1.429E+05 6.336E+06

slope y-intercept ICAO


n r r^2 m c Patm/Pascal % error
11 0.8746 0.7650 5.3270 -99135 101325 -2.16%

Conclusion/Graph

Page 1
Boyle P>Patm

7.000E+02
Boyle P>Patm
6.000E+02

5.000E+02
P/Pascal

4.000E+02

3.000E+02

2.000E+02

1.000E+02

0.000E+00
1.862E+04 1.864E+04 1.866E+04 1.868E+04 1.870E+04 1.872E+04 1.874E+04
V^-1/m^-3

In this experiment, it shows the relationship between voulun and pressure in the
constant temperature. As the pressure increase , the volumn is decrease. On the
other hand, if the pressure decreses, the volumn is increases. The reason why the
pressure increase is because the gas pressure in sealed syringe collision with each
other and the wall of syringe.
In the experiment, the error is 2.16 percent. It might be from the human error as
we reading and measuring the tempurature, volumn and lenght etc. Also,
between the pipette and syringe is not seal properly so the gas may leak out

Page 2

Vous aimerez peut-être aussi