Vous êtes sur la page 1sur 2

Seismic Loads for Liquid‐Containing Rectangular RC Tank, According ACI 350.

3‐06 , Appendix B Method
Based on 1997 Uniform Building Code Rev1.0
Project :‐ Project Designed by:‐ M. Abu Shady
Building :‐ Building Checked by:‐ M. Abu Shady
Element:‐ Element Date:‐ 11‐Jan‐18
Location:‐ Location M.A.S.
General Input :‐
tr= 0.00 m

Seismic Force
Direction of
L= 11.65 m tw= 0.50 m HL= 5.40 m Hw= 6.00 m
γL= 10.0 KN/m3

B= 5.00 m
Rectangular Tank Plan Rectangular Tank Elevation

γc= 24.0 KN/m3
fc= 35.0 N/mm2 Ec= 27805.6 N/mm2 ACI318‐08, Clause 8.5.1
g= 9.81 m/sec2

Importance factor I = 1.00 ACI 350.3‐06, Table 4.1.1(a)


Rc = 1.00 ACI 350.3‐06, Table 4.1.1(b)
Ri = 1.00 ACI 350.3‐06, Table 4.1.1(b)
SEISMIC ZONE 3
Z factor 0.3 UBC 97, TABLE 16‐I
Soil Profile  Very Dense
Soil Profile Type SC UBC 97, TABLE 16‐J
Na For Zone 4 only 1 UBC 97, TABLE 16‐S
Nv For Zone 4 only 1 UBC 97, TABLE 16‐T
Ca 0.330 UBC 97, TABLE 16‐Q
Cv 0.450 UBC 97, TABLE 16‐R
Ts =0.40Cv/Ca 0.545 sec, UBC 97, FIGURE 16‐3

1‐Calculation the Equivalent Weight for impulsive Wi & convective Wc component:

WL = 3145.5 KN  , L / HL = 2.16 ,Ww = 2541.6 KN ,Wr = 0.0 KN

= 0.51 WL = 1605.2 KN ACI 350.3‐06, Eq 9‐1

= 0.51 WL = 1609.8 KN ACI 350.3‐06, Eq 9‐2

2‐Calculation the Height of center of gravity for impulsive hi & convective hc components:

= 2.025 m ACI 350.3‐06, Eq 9‐3 & Eq 9‐4

= 3.098 m ACI 350.3‐06, Eq 9‐5

3‐Calculation the fundamental period of oscillation of the tank for impulsive Ti & convective Tc components:

= 4146.8 KN = 3.00 m        , = 6.00 m


,

= 2.62 m , = 48172.0 KN/m ACI 350.3‐06, R9.2.4

= 0.59 sec ACI 350.3‐06, Eq 9‐11

= 5.28 = 4.06 sec ACI 350.3‐06, Eq 9‐13,14

= ,∴ =( ∗ = 392.4 KN/m

Page 1 of 2
Seismic Loads for Liquid‐Containing Rectangular RC Tank, According ACI 350.3‐06 , Appendix B Method
Based on 1997 Uniform Building Code Rev1.0
Project :‐ Project Designed by:‐ M. Abu Shady
Building :‐ Building Checked by:‐ M. Abu Shady
Element:‐ Element Date:‐ 11‐Jan‐18
Location:‐ Location M.A.S.
4‐Calculation the total lateral impulsive force Pi & convective force Pc :

= 0.765 ACI 350.3‐06, Appendix B, Eq B‐1,2,3

= 0.120 ACI 350.3‐06, Appendix B, Eq B‐4,5

= 1943.2 KN = 0.0 KN ACI 350.3‐06, Appendix B, Eq B‐6,7

= 1227.3 KN = 193.0 KN ACI 350.3‐06, Appendix B, Eq B‐8,9

5‐Calculation the total Base Shaer V:
= 3176.3 KN ACI 350.3‐06, Appendix B & Eq 4‐5
6‐Dynamic force distribution above base per Wall perpendicular to ground motion:

Pi Top = 5.7 KN/m2

Pi Bottom = 39.8 KN/m2

Pc Top = 5.2 KN/m2 ACI 350.3‐06, R5.3.1

Pc Bottom = 2.0 KN/m2

= 29.4 KN/m2

= 29.4 KN/m2 = 29.4 KN/m2
= 5.7 KN/m2 = 5.2 KN/m2 = 40.3 KN/m2

= 39.8 KN/m2 = 2.0 KN/m2 = 71.2 KN/m2


Wall Inertia Force Pw Impulsive Force Pi  ConvectiveForce Pc Total Seismic Force E per Wall
perpendicular to ground motion
Dynamic force distribution above base per Wall perpendicular to ground motion

Page 2 of 2

Vous aimerez peut-être aussi