Vous êtes sur la page 1sur 2

Chairman,

Electrical Enginering Technical Division,


The Institution of Engineers Malaysia,
Lots 60 & 62, Jalan 52/4, P.O. Box 223 (Jalan Sultan), The Institution of Engineers, Malaysia
46720 Petaling Jaya, Selangor Darul Ehsan
Tel: 03-7968 4001/2 Fax to 03-7957 7678
Email: fauzi@iem.org.my One Day Seminar on
REGISTRATION FORM
MS IEC 62305 Series MS IEC 62305 Series
29th October 2013 at Wisma IEM, Petaling Jaya Organised By:
th
Closing Date : 24 October 2013
Electrical Engineering Technical Division, IEM
No Name(s) M’ship No. Grade Fee (RM)* Date : 29th October 2013 (Tuesday)
Venue : C&S and TUS Lecture Room, 2nd Floor
Wisma IEM, Petaling Jaya, Selangor
Time : 8.50 a.m. - 5.30 p.m.

Total Payable BEM Approved CPD/PDP Hours = 5.5


Ref. No: IEM13/HQ/250/S
*Fees MUST be fully paid BEFORE the CLOSING DATE. Seats could only be confirmed upon payment.

Enclosed herewith a crossed cheque No: ______________________for the sum of RM ___________ Registration Fee Normal On-line
issued in favour of “The Institution of Engineers, Malaysia” and crossed ‘A/C payee only’. I/We
understand that the fee is not refundable if I/We withdraw after my/our application is accepted by the
IEM Graduate Member : RM200.00 RM180.00
Organising Committee as stated in the cancellation term. If I/We fail to attend the seminar, the paid IEM Corporate Member : RM300.00 RM280.00
registration fee will not be refunded. Non IEM Member : RM450.00 RM430
RM430.00
430.00
Contact Person: _______________________________________________ Designation:_____________________

Name of Organization: __________________________________________________________________________


IMPORTANT NOTES
Address: _____________________________________________________________________________________ • Closing Date : 24th OCTOBER 2013 (FRIDAY)
• For ONLINE REGISTRATION, payment MUST BE MADE VIA ONLINE PAYMENT [via RHB Now
_____________________________________________________________________________________
and Maybank2u -Personal Saving & Personal Current; Any Credit Card - Visa/Master]. If
Telephone No.: _________________________________(O) ___________________________________ (Fax)
payment is not received within the stipulated time, the registration fee will automatically be
reverted to the normal fee.
_________________________________ (H) ____________________________________ (HP) • Payment via CASH/CHEQUE/BANK-IN TRANSMISSION/BANK DRAFT/MONEY ORDER/
POSTAL ORDER/LOU/LOG/WALK –IN will be considered as NORMAL REGISTRATION
Email: ______________________________________________________________________________________ • FULL PAYMENT must be settled before commencement of the event, otherwise participants
will not be allowed to enter the hall. If a place is reserved and the intended participant fails to
attend the course, the fee is to be settled in full. If the participant failed to attend the course, the
fee paid is non-refundable. IEM reserve the right to reject any LOU/LOG not in accordance with
____________________________________ ________________________________ these instructions.
Signature & Stamp Date • The Organising Committee reserves the right to alter or change the programme due to
unforeseen circumstances.
Photocopies are acceptable
Synopsis
Course Schedule & Outline
Lightning is a fascinating phenomenon, and at the same time may be lethal. Protection of people,
livestock, buildings and equipment, especially modern IT and medical equipment against lightning Time Programme Speaker
hazards is indispensible in electrical system design. The guidance given by BS 6651: Code of
Practice for Protection of Structure against Lightning practiced in Malaysia may underestimate the 0830- 0850 Course Registration
threat and the protection against lightning hazards.
The new IEC 62305 (MS IEC 62305) international standards series, which replaces BS 6651(Replaced 0850-0900
Welcome address by Session Chairman
by BS EN 62305) addresses the shortcomings of BS 6651. The objectives of this course is to discuss Part 1:
the problems caused by lightning, the effective protection solutions to ensure electrical system *Lightning levels and characteristics Mr. Ray
0900-1000
reliability and business continuity and profitability, and the key changes of IEC 62305 standards *Summary of main differences between MSIEC 62305 and BS 6651/MS939
compared with BS 6651. * Definitions of LPS and LPMS
Part2:
About The Course Leaders Simulation Run on Risk assessment (including UK software examples):
1000-1045 * Need to run the simulation for R1, R2, R3 and R4 (if possible used the local Mr. Kwan
Mr. A Samad Khan worked for W J Furse & Co, Ltd which was later acquired by Thomas & Betts lightning density as for local consultant designing need)
right after he graduated with a Master degree (Meng Honours) in Electronic and Electrical *Decision making from the risk simulation to Produce: protection measure"
Engineering from Loughborough University, England in 1996. He has extensive knowledge and Example of the Level of protection LPS design to the typical local lightning
density simulation with outcome solution.
experience, in the field of protection against lightning which includes research and design of
simulation and generation of lightning for testing and development of protection components, and 1045-1100 Tea Break
field applications of lightning and surge protection. Since 2001, Khan was appointed by the British Part 3:
Standards Institute to represent the UK as its principle expert on several global committees * Definitions of the classes of structural lightning protection systems
(CENELEC and IEC) involved with lightning protection. He is also a consultant to the BS 7671 (IEE *Designing an air termination system using the protective angle, rolling
wiring regulations). Mr. Khan is a Chartered Engineer (CEng) since Year 2004 with the Institute of sphere and mesh methods
Electrical Engineers, now known as the Institute of Engineering and Technology.
* Definitions of the classes of structural lightning protection systems
1100-1300
Mr. Kwan Lung graduated with Bachelor of Engineering with honours (Electrical) from University of *Designing an air termination system using the protective angle, rolling
Mr. Kwan
Melbourne, Australia in year 1992. He further completed a Master of Science (Management of sphere and mesh methods
Technology) National University of Singapore in year 2001. He has more than 20 years’ experience * Down conductor systems
in utility industry and in depth knowledge in Power generation, transmission and distribution and Earth termination systems
field commissioning experience. He was worked on numerous projects such as HK Black Point * Separation (isolation) distance of the external LPS
Power Station (Hong Kong), 230kV and 660kV Power Grid substations in Singapore, and 11kV- * The application of surge protection devices in protecting structure (Type I)
33kVdistribution network around South Asia Countries. Mr. Kwan provides system and technical * Maintenance and Inspection of LPS
solutions to utility customer on Var compensation, voltage regulation, over current protection and
grounding design in Asia regions. 1300–1400 Lunch Break
Part 4:
Mr. Khan Wai Mun (Ray) graduated with Bachelor in Electrical Engineering at University at * LEMP Protection Measure System (LPMS)
1400-1515
Newscastle Australia, year 2002; He started his engineering career with system integrator *LPZ concept Mr. Samad
in proposing, tendering and managing projects in Asia. He joined Phoenix Contact in * Earthing and bonding
Year 2008 where he acquired an extensive and in-depth knowledge in surge protective device * Line routing and shielding
(SPD) and protective methods for electrical and electronic systems and equipment against
1515-1530 Tea Break
electrical transients.
*Co-coordinated SPDs
Cancellation Policy 1530-1700 Inspection and maintenance of LPMS
IEM reserves the right to postpone, reschedule, allocate or cancel the course. Full refund less 30% if * Case study (Similar to the Furse Lightning Consultant/Engineer Guide Book) Mr. Samad
cancellation is received in writing more than 7 days before start date of the event. No cancellation will * BS 7430
be accepted prior to the date of the event. However, replacement or substitute may be made at any
Q&A
time with prior notification and substitute will be charged according to membership status.

Vous aimerez peut-être aussi