Vous êtes sur la page 1sur 4

Wire diameter

Samples Oil Distance (mm) Observations


(mm)

No Crack
PC III DOP 0.46 30.3
+ 24 hours

No Crack
PC IV DOP 0.46 30.1
+ 24 hours

No Crack
PC Transparent DOP 0.46 30.1
48 hours

No Crack
PC white DOP 0.46 30.1
48 hours

No Crack
PC Transparent DOP 0.60 30.1
+72 hours

No Crack
PC white DOP 0.60 30.1
+72 hours

Wire diameter
Samples Oil Distance (mm) Observations
(mm)

No Crack
PC I TOTM 0.46 30.1
38 hours

Crack (5-8 a.m)


PC II TOTM 0.46 30
12 hours Appox

No Crack
PC III TOTM 0.46 30.1
+24 hours

No Crack
PC I TOTM 0.60 30.1
+72 hours

No Crack
PC III TOTM 0.60 30.1
+72 hours
Wire diameter
Samples Oil Distance (mm) Observations
(mm)

No Crack
PC I DOP 0.60 30.1
+48 hours

No Crack
PC white DOP 0.60 30
+48 hours

No Crack
PC III DOP 0.60 30
+48 hours

No Crack
PC Transparent DOP 0.60 30.1
+48 hours

Note: the dimension are the same for all the samples (35 x 11 x 2.1)

In this case temperature was kept 40 °C

Wire diameter
Samples Oil Distance (mm) Observations
(mm)
Started: 6:10 min
PC I DOP 0.60 30.1 Middle: 7:15 min
Failure: 8:10 min
Started: 3:40 min
Middle: 4:40 min
PC white DOP 0.60 30
Complete: 5:38 min
Failure: 6:10 min
Started: 7:15 min
PC III DOP 0.60 30 Complete: 7:50 min
Failure: 8:15 min
Started: 2:10 min
PC Transparent DOP 0.60 30.1 Middle: 2:45 min
Failure: 3:30 min
Samples testing in chemical department with TOTM (0.45) Date: 05/01/2016

Wire diameter
Samples Oil Distance (mm) Observations
(mm)

PC I TOTM 0.45 30.1 Running

PC white TOTM 0.45 30 Running

PC III TOTM 0.45 30 Running

PC Transparent TOTM 0.45 30.1 Running


Samples testing in chemical department with DOP (0.45) Date: 12/01/2016

Wire diameter
Samples Oil Distance (mm) Observations
(mm)

2 hours and 45
PC I DOP 0.45 30.1
minutes

Crack not Fracture,


PC white DOP 0.45 30
5 days and 4 hours

PC III DOP 0.45 30 5 days and 7 hours

PC Transparent DOP 0.45 30.1 3 days and 5 hours

PC IV DOP 0.45 30 Running

Vous aimerez peut-être aussi