Académique Documents
Professionnel Documents
Culture Documents
1. Make Folder with CIF and DAT files. Open Fullprof Suite. ED-PCR. CIF-PCR. Open CIF file. Save.
PCR file is created.
2. Go to Editor. Open PCR file. Change job value from 2 to 0. Save. Close.
3. Cycle of refinement to 3, force termination to 0.3 (0.1 is only for Synchrotron sources. For lab
sources, it should be 0.3); Check Profile Matching Mode in the ‘Others’ option. For pure
material, enable ‘only first cycle’.
4. Instrumental: Zero.
5. Profile: Scale Factor.
6. Background: Refine 1st background parameter. In case of sloppy background, it is wise to
refine 2-3 parameters. Save the last 3 parameters for the end.
7. Profile: Lattice constants (a,b,c, alpha, beta, gamma).
8. Atoms: Refine atomic positions for the individual atoms in the unit cell.
9. Profile: Peak shape parameters (U,X,V,W and Y) individually.
10. Atoms: B factors for the individual atoms followed by the Occupancies (or vice versa).
11. Background: Add the additional background parameters.
12. The refinement strategy is now modified on a ‘case-to-case’ basis for including effects like
anisotropic thermal movements, asymmetric peaks, preferred orientations in the samples etc.
Upon attaining a good enough value of 2 (< 10), perform the following checks:
The values of the R-factors are at least below 20. Rexp should ideally be a single digit value.
The values of U,W,X and Y should be positive and V should be negative.
Confirm that the B-factors (Overall or B_iso) are positive – a negative value is incorrect!
Check the occupancies – make sure that the values are non-negative and make sense in
terms of the particular sample.
Inspect the residual curve carefully – it can provide valuable information about the quality of
the fit and the errors made.
1. Run BondSTR.
2. There’s a bug here. In ‘File’, select ‘Import CIF’. Select the CIF that has been generated. Our
refinement program overwrote the original CIF.
3. In ‘File’, now ‘Open’ the CFL file (that has now been mysteriously generated – some bug, eh?)
4. Enable the ‘restraints output’ as well.
5. For ‘Dist. Angl’, change the values to (3.4, 2.7)
6. Make the default Tolerance to 10.
7. Put the respective valencies of the ions in the unit cell in front of the respective labels in the
table.
8. Run the BondSTR program by clicking the icon located below the ‘Help’ button on top.
9. This will generate a .BVS file with all bond angle information.
1. Run WinPlotr.
2. In the ‘File’ menu – choose the ‘Open Rietveld/profile file’.
3. From the pop-up menu, choose ‘101: FullProf PRF file’ and open the PRF file generated from
the refinement.
4. The fitted profile will be visible in the WinPlotr window.
5. In the ‘File’ menu – choose ‘Save data as…’ and ‘Save data as XYY file.’ Ensure that all 4
checkboxes are ticked.
6. This should generate an XYY file that can be then plotted in Origin.
This is the end of Rietveld Refinement using FullProf Suite. You now have all the information (five
important parameters – structural information (from XRD), electron density, atomic coordination,
bond angle and bond lengths. Success!