Académique Documents
Professionnel Documents
Culture Documents
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
People’s Republic
of China
DC Filters 668 Guiping Road
Shanghai, 200233
TE has developed a wide range of power Phone: 86-21-2407-1588
line filters and power entry modules that Fax: 86-21-2407-1599
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
3
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
For
Selector charts at the beginning of each Attenuate
Conducted Coming Out
of Equipment
Hardened
Equipment Yes
Yes RFI / EMI Applications
section help you to narrow the selection. Try The
No
AQ
Coming Into Series
Try The Equipment For 3-6A
Follow the chart to locate one or several
MV
Switch
Mode Power
Page 12
Series Supply
product series that could fit your specific
3-20A
Page 54
No Yes
NEW
3-6A Series
Page 37 3-20A
Try The Try The Page 65
B EBP, EDP,EOP SK
Selector charts generally show filters in Series Series Series
1-30A 1-10A 3-40A
order of performance from good (at the top) Page 15 Page 21 Page 75
SB B EMC
to best performance (at the bottom).
NEW
Series Series Series
6- 30A 1- 30A 3-30A
All Series Try The Page 71 Page 15 Try The Page 24
Are Listed in
N ew 6 0 A
Ascending
Performance EMC K SB Z S
NEW
Series Series Series Series Series
FC DK K U V/W
Each product series contains three technical sections.
Series
6-50A
The
Series majority
Good
1-20A
Series of questions
1-60A
Series
6A
relating
Series
3-20A
to
to product applications can be answered directly from these sections.
Page 30 Page 18 Page 49 Page 84 Page 86
New 60A
New Terminations
S WG DK N EP / VP
Series Series Series Series Series
3-60A 16A 1-20A 6-10A 3-20A
Better
Page 68 Page 89 Page 18 Page 56 Page 27
the recommended cutouts. Dimensions are shown in inches with metric equivalents.
Performance Data: The third section contains performance data in the form of typical
insertion loss graphs and minimum insertion loss tables.
If you already know the catalog number or series, the table of contents lists each series in
the catalog within each section. The back of the catalog also has an index in alphanumeric
order. The index will reference the technical section for that catalog number or series.
The index also provides the unique TE ordering number for each part.
4
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
The efficiency of an electrical device is the ratio of the power it delivers to the
E power that it consumes. The difference is wasted as heat, and to prevent over-
e
bl heating of a device and the system in which it resides, this heat must be
ffi
Relia
cient
transferred out of the system and dissipated. The efficiency of every component,
including the power entry module and selected filter, factors into the system’s
overall efficiency. When the amount of heat is too great to dissipate through the
system’s enclosure, forced air cooling becomes necessary. This is often accom-
C o ol plished with a fan, and the power used by that fan, (including its own thermal
losses) further decreases the system efficiency by another 2% to 5%. Providing
room for the fan and air passageways in the equipment increases its size and
cost. Careful attention to the efficiency of every component in the system results
in a simpler, smaller, lighter, cooler, more competitive product.
Corcom EMI filters can help meet energy efficiency goals, including Energy Star
rating and the new 80 Plus certification, which now recognizes systems that
exceed 90% efficiency. By using the most energy efficient design and materials,
Corcom filters can be the beginning of an energy efficient system strategy.
Energy efficient power components don’t just lower energy bills and demand for
power from the grid, they also increase product reliability. Small efficiency
increases can decrease component temperatures throughout the system, and
semiconductor life doubles for every 10°C decrease in temperature. Corcom filters
are more efficient and run cooler, and this can help reduce system warranty costs,
service calls and total support costs.
Corcom filters
• Have heat dissipation ratings as little as one third that of comparable filters.
• Create less heat and run cooler
• Improve system reliability
• Are more efficient than PC board equivalents
• Can help meet system power efficiency standards
• Enable systems to be smaller and lighter
• Save customers money by reducing energy costs
500
450
Heat Dissipation in mW/A
400
350
300
250
200
150
100
1A Corcom CU Series
3A
5
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
TE Connectivity Corcom products were established as the world Corcom Custom Filters
leader in EMI/RFI filtering technology with the introduction of the Key Features:
first line of catalog filter products over 50 years ago. • Custom filter options
Today, TE continues to pursue the latest in EMI/RFI filter design • Custom wire harness
by testing and evaluating application specific solutions for a wide design
range of industries. • Fully customizeable
options including
In addition to our complete catalog of standard EMI/RFI filtering packaging
solutions, TE offers a full range of engineering services and • Agency approvals
custom products designed for unique applications. available as needed by
customer
Corcom custom EMI/RFI product solutions can: • Time and cost savings
to customer
• Optimize both cost and performance to target a unique
application • Simplify installation
• Fit unique mechanical size, installation and/or connection Termination and Wiring
requirements Customization Options:
6
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
7
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
Corcom EMI / RFI Product Solutions for Facility and Heavy Power
8
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
9
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
Engineering Notes
10
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
For
Medical No
Application
For
Attenuate Hardened
Coming Out
Yes
Conducted
RFI / EMI
of Equipment
Equipment
Applications
Yes
Try The
1
No
AQ
Coming Into Series
HZ For
Series For High EN550xxx Class A
3A Noise Industrial
(CISPR)
Page 43 Application
NEW
3-6A Series
Page 37 3-20A
Try The Try The Page 65
B EBP, EDP,EOP SK
Series Series Series
1-30A 1-10A 3-40A
Page 15 Page 21 Page 75
SB B EMC
NEW
N ew 6 0 A
Ascending
Performance EMC K SB Z S
NE W
Good FC DK K U V/W
Series Series Series Series Series
6-50A 1-20A 1-60A 6A 3-20A
to
Page 30 Page 18 Page 49 Page 84 Page 86
New 60A
New Terminations
S WG DK N EP / VP
Series Series Series Series Series
3-60A 16A 1-20A 6-10A 3-20A
Better
Page 68 Page 89 Page 18 Page 56 Page 27
Best T R EMC FC T
Series Series Series Series Series
3-20A 1-20A 3-30A 6-50A 3-20A
Page 80 Page 61 Page 24 Page 30 Page 80
11
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
AQ Series
UL Recognized
CSA Certified 3VAQ8F
6VAQ8F
AQ Series Specifications
• Low cost solution to power line noise at high Maximum leakage current each Line to Ground:
frequencies 3A Models 6A Models
@ 120 VAC 60 Hz: 1.2 mA .7 mA
• High common and differential mode performance
@250 VAC 50 Hz: 2.3 mA 1.2 mA
from 10kHz to 1GHz
• Available with an IEC inlet, fuseholder and switch Hipot rating (one minute):
Line to Ground: 2250 VDC
• Suitable for applications where computers are Line to Line: 1450 VDC
used to process secret or confidential information
Rated Voltage (max): 250 VAC
AQ Series 6A Models
LINE LOAD
Leakage current designation
V – Standard
Current Rating
3 or 6A Accessories
GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord
Available Part Numbers
3VAQ3 6VAQ3
3VAQ8F 6VAQ8F
3VAQ8FS 6VAQ8FS
*IEC 60320-1 C14 inlet mates with C13 connector
12
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
AQ Series
Case Styles and Dimensions
3VAQ3 6VAQ3
2.46
62.3
CL 1.66 ± .015
42.1 ± .38
2.572 C
L
1
65.3
3VAQ8F 6VAQ8F
5.96 6.457
152.0 164
5.68 ± .01
5.06 ± .015
44.3 ± .25
128.6 ± .38
4.0 ± .01
2.35 ± .015 .90 102 ± .25
59.6 ± .38 22.9
2.328 ± .01
1.125 ± .01 3.062
59 ± .35
1.58 ±.015 .958 2.48 28.6 ± .25 77.8
40 ± .38 24.3 63.0
3VAQ8FS 6VAQ8FS
5.39 ± .015 7.125
136.9 ± .38 .172 181.0
1.058 6.347 ± .015
4.37
2.35 ± .015 26.9 161.2 ± .38
59.6 ± .38 #6-32 4.0 ± .015
(6) inserts 101.55 ± .25
.44
11.2
1.575 ± .015 .958 2.48
40.01 ± .38 63.0 2.33 ±.015
24.3 1.52 ± .01 3.07
59.0 ± .38
38.5 ± .25 77.8
.411 #6-32
ref (6) inserts .364
10.4 1.12 ± .01 .391 ± .01
.375 ± .125 9.25 28.3 ± .25 9.93 ± .25
9.53 ± 3.2 12.0 Min.
1.62 304.8
41.2
2.58
65.4
12.0 Min. 6.30 .375 ± .125
305.0 160.0 9.53 ± 3.2
13
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
AQ Series
Recommended Panel Cutouts
.910 ± .005
23.11 ± .13 .855 ± .005
.235 ± .005
R 21.72 ± .13
5.969 ± .13
.620 ± .005
15.75 ± .13
1.295 ± .005
32.89 ± .13
.620 ± .005
Dia.
15.75 ± .13
Performance Data
3VAQ 6VAQ
db db
100 100
90 90
80 80
70 70
60 60
50 50
40 40
30 30
20 20
10 10
0 0
0.01 0.1 1 10 100 1000 0.01 0.1 1 10 100 1000
Frequency in MHz Frequency in MHz
Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line)
14
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
General Purpose RFI Filters for High Impedance Loads at Low Current
B Series
UL Recognized
CSA Certified
VDE Approved
VB6
B Series Specifications
• Small size & low cost Maximum leakage current each Line to Ground:
• General purpose VB Models EB Models
@ 120 VAC 60 Hz: .4 mA .21 mA
• Wide variety of termination options @250 VAC 50 Hz: .7 mA .36 mA
• Meets low leakage current requirements of VDE Hipot rating (one minute):
portable equipment and non-patient medical Line to Ground: 2250 VDC
equipment Line to Line: 1450 VDC
Rated Voltage (max): 250 VAC
Operating Frequency: 50/60 Hz
Ordering Information
Rated Current: 1 to 30A
10 E B 1 Operating Ambient Temperature Range
(at rated current Ir): -10°C to +40°C
Input / Output Style In an ambient temperature (Ta) higher than +40°C
1 – .250 [6.3] spade terminals the maximum operating current (Io) is calculated as
3 – Wire leads follows: Io = Ir (85-Ta)/45
6 – Threaded bolt
B Series
15
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
General Purpose RFI Filters for High Impedance/ Low Current (continued)
B Series
Case Styles
B1 30VB6
E D B
E D B
2.00
50.8
A C A C
B3 Case Dimensions
A B C D E
Part No.
Blue Blue
Green/Yellow 1VB1, 1EB1,
E D B
Brown Brown 2VB1, 2EB1
1VB3, 1EB3,
2VB3, 2EB3
3VB1, 3EB1,
A C 5VB1, 5EB1
3VB3, 3EB3,
5VB3, 5EB3
10VB1, 10EB1
10VB3, 10EB3
10VB6 & 20VB6
10VB6
20VB1, 20EB1
E D B
20VB6
30VB6
A C
16
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
General Purpose RFI Filters for High Impedance/ Low Current (continued)
B Series
Performance Data Common Mode / Asymmetrical (L-G)
Differential Mode / Symmetrical (L-L)
Typical Insertion Loss
Measured in closed 50 Ohm system
1EB & 3EB
db
100
2EB, 5EB & 10EB
db
100
20EB
db
100
1
90 90 90
80 80 80
70 70 70
17
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
DK Series
DK3
UL Recognized
CSA Certified
VDE Approved
DK1
DK6
DK Series Specifications
• Higher performance Line to Line attenuation than Maximum leakage current each Line to Ground:
the K Series VDK Models EDK Models
@ 120 VAC 60 Hz: .4 mA .22 mA
• E version meets the low leakage current
@250 VAC 50 Hz: .7 mA .38 mA
requirements of VDE portable equipment
and non-patient care equipment Hipot rating (one minute):
Line to Ground: 2250 VDC
• V version features same high performance
Line to Line: 1450 VDC
with more cost-effective design
Rated Voltage (max): 250 VAC
Operating Frequency: 50/60 Hz
Ordering Information
Rated Current: 1 to 20A
10 E DK 3 Operating Ambient Temperature Range
(at rated current Ir): -10°C to +40°C
Input / Output Style In an ambient temperature (Ta) higher than +40°C
1 – .250 [6.3] spade terminals the maximum operating current (Io) is calculated as
3 – Wire leads follows: Io = Ir (85-Ta)/45
6 – Threaded bolt
DK Series
18
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
DK Series
Case Styles
E
D
C
1
E D B
A
A C
VDK3 / EDK3
E C
D
Case Dimensions
A B C D E
Blue Blue Part No.
A C
19
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
DK Series
Performance Data
Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line)
20
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
UL Recognized*
CSA Certified*
VDE Approved* 1EDP / 1EOP 1
EBP Series
Compact Size
EDP & EOP
EDP Series
LINE LOAD
Enhanced Performance
EOP Series
General Performance
21
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
LINE
.787
20.00
B
.394
10.00
LOAD
1EBP 3EBP
.35 db db
Max.
8.97 100 100
90 90
80 80
70 70
60 60
.31 ± .02 50 50
LINE LOAD
40 40
7.87 ± .5
30 30
20 20
.591 ± .006 10 10
B 15.00 ± .15 0
0.1 1 10 30
0
0.1 1 10 30
Frequency in MHz Frequency in MHz
.295 ± .006
7.50 ± .15
.689 ± .006
17.50 ± .15
.36 ± .02 Common Mode / Asymmetrical (L-G)
9.10 ± .5
Differential Mode / Symmetrical (L-L)
22
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
1EDP
db
100
3EDP
db
100
6EDP
db
100
10EDP
db
100
1
90 90 90 90
80 80 80 80
Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line)
23
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
EMC Series
UL Recognized
CSA Certified
VDE Approved
EMC6 EMC1
Case Styles
1 – .250 [6.3] spade terminals
3 – Wire leads
6 – Threaded bolt
EMC Series
Current Rating
Available Part Numbers
3, 6, 10, 15, 20 or 30A 3EMC1 10EMC3
6EMC1 15EMC3
10EMC1 10EMC6
15EMC1 15EMC6
20EMC1 20EMC6
3EMC3 30EMC6
6EMC3
24
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
Compact and Cost-effective Dual Stage RFI Power Line Filters (continued)
EMC Series
Case Styles
EMC1 30EMC6
1
B
D C
E
A
A C
25
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
Compact and Cost-effective Dual Stage RFI Power Line Filters (continued)
EMC Series
Performance Data
20EMC 30EMC
db db
100 100
90 90
80 80
70 70 Common Mode / Asymmetrical (L-G)
60 60
Differential Mode / Symmetrical (L-L)
50 50
40 40
30 30
20 20
10 10
0 0
0.1 1 10 30 0.1 1 10 30
Frequency in MHz Frequency in MHz
26
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
Dual Stage RFI Power Line Filters for Switching Mode Power Supplies
EP / VP Series
EP / VP Series
Case Styles
EP1 / VP1 (1-15A) EP7 & EP7M
Tapped insert
B
D B
D
E
A C A E
C
B B
D D
E E
A C
A C
28
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
EP / VP Series
Case Dimensions Typical Insertion Loss (continued)
A B C D E 12EP 20EP
Part No. db db
100 100
3EP1
3EP3
90
80
70
60
90
80
70
60
1
50 50
40 40
10EP3
0
0.01 0.1 1 10 30
12EP1
Minimum Insertion Loss
Measured in closed 50 Ohm system
12EP3 Common Mode / Asymmetrical (Line to Ground)
20EP1/VP1
20EP6/VP6
Performance Data
Typical Insertion Loss
Measured in closed 50 Ohm system
3EP 6EP
db
db
100 100
90
90
80 80
70 70
60 60 Differential Mode / Symmetrical (Line to Line)
50 50
40 40
30
20
30
20
10 10
0
0.01 0.1 1 10 30 0
0.01 0.1 1 10 30
Frequency in MHz Frequency in MHz
29
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
FC Series
UL Recognized
FC Series Specifications
• Designed for frequency inverters and variable Maximum leakage current each Line to Ground:
speed motor drives B suffix no suffix
@ 120 VAC 60 Hz: 3.9 mA 3.8 mA
• Suitable for electronically noisy environments
@250 VAC 50 Hz: 7.0 mA 6.7 mA
• Protects programmable logic controllers from RF
noise on the AC power line Hipot rating (one minute):
Line to Ground: 2250 VDC
• Side flanges for easy mounting Line to Line: 1450 VDC
• Touch safe terminals provide easy connections Rated Voltage (max): 250 VAC
and prevent inadvertent contact for safety in the
most demanding applications Operating Frequency: 50/60 Hz
Rated Current: 6 to 50A
Operating Ambient Temperature Range
(at rated current Ir): -10°C to +40°C
Ordering Information In an ambient temperature (Ta) higher than +40°C
36 FC 10 B the maximum operating current (Io) is calculated as
follows: Io = Ir (85-Ta)/45
Suffix
B – Single stage Electrical Schematics
Omit for dual stage FC10
Input / Output Style LINE LOAD
10 – DIN type terminal block
1
2
FC Series
1
30
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
FC Series
Case Styles Case Dimensions
A B C D E F
FC10 / FC10B (6, 12, 16A) Part No.
6FC10
12FC10/10B
1
B D 16FC10/10B
C F
E
This hole indicates A
the "Line" side and
may be on either flange.
B D
C F
E
A
31
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
FC Series
Performance Data
Common Mode / Asymmetrical (L-G)
Typical Insertion Loss Differential Mode / Symmetrical (L-L)
Measured in closed 50 Ohm system
6FC10 12FC10 16FC10
db db db
100 100 100
90 90 90
80 80 80
70 70 70
60 60 60
50 50 50
40 40 40
30 30 30
20 20 20
10 10 10
0 0 0
0.01 0.1 1 10 30 0.01 0.1 1 10 30 0.01 0.1 1 10 30
Frequency in MHz Frequency in MHz Frequency in MHz
32
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
FL Series
UL Listed
1
FL Series
LINE LOAD
Current Rating
3 – 3.9A
33
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
FL Series
Case Styles Case Dimensions
A B C D E
Part No.
C D
3FL3
Load
0.44
11.18
B
0.44
Line
7.0
177.8 E
Min.
(4 Wires)
Strip
0.50
12.7
(Typ)
A
18 AWG (4X)
Performance Data
3FL3
db
100
90
80
70
60 Differential Mode / Symmetrical (L-L)
50
40
30
20
10
0
0.1 1 10 30
Frequency in MHz
34
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
G Series
UL Recognized
CSA Certified
VDE Approved 10EG1 / 10VG1
1
G Series Specifications
• Designed to provide excellent attenuation for Maximum leakage current each Line to Ground:
most digital electronics equipment EG Models VG Models
@ 120 VAC 60 Hz: .30 mA 1.2 mA
• Broad frequency range of performance from
@250 VAC 50 Hz: .50 mA 2.0 mA
20kHz to 30MHz
• Size and cost-effective solution Hipot rating (one minute):
Line to Ground: 2250 VDC
• Designed to help comply with EN55022 Level A Line to Line: 1450 VDC
and FCC Part 15J Class B
Rated Voltage (max): 250 VAC
Operating Frequency: 50/60 Hz
Rated Current: 6 & 10A
Ordering Information Operating Ambient Temperature Range
10 E G 1 (at rated current Ir): -10°C to +40°C
In an ambient temperature (Ta) higher than +40°C
the maximum operating current (Io) is calculated as
Input / Output Style follows: Io = Ir (85-Ta)/45
1 – .250 [6.3] spade terminals
Current Rating
6 or 10A
35
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
G Series
Case Styles Case Dimensions
A B C D E
Part No.
6EG1/VG1
B
10EG1/VG1
D C
E
A
Performance Data
36
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
HQ Series
3EHQ3
UL Recognized
1
6EHQ8
CSA Certified
VDE Approved
HQ Series Specifications
• Designed to provide the highest available Maximum leakage current each Line to Ground:
attenuation of RFI noise in the frequency range @ 120 VAC 60 Hz: 2 A
from 10kHz to 30MHz for low leakage current @250 VAC 50 Hz: 5 A
applications Hipot rating (one minute):
• Size and cost-effective Line to Ground: 2250 VDC
Line to Line: 1450 VDC
Rated Voltage (max): 250 VAC
Operating Frequency: 50/60 Hz
Rated Current: 3 & 6A
Operating Ambient Temperature Range
(at rated current Ir): -10°C to +40°C
In an ambient temperature (Ta) higher than +40°C
the maximum operating current (Io) is calculated as
follows: Io = Ir (85-Ta)/45
Ordering Information
6 E HQ 8 M
Suffix
Available Part Numbers
M – Metric inserts (style 8 only) 3EHQ1 6EHQ1
Omit for standard or none 3EHQ3 6EHQ3
3EHQ8 6EHQ8
Input / Output Style 3EHQ8M 3EHQ8M
1 – .250 [6.3] spade terminals
3 – Wire leads
8 – IEC inlet* (line side)
Wire leads (load side) Accessories
GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord
HQ Series
Current Rating
3 or 6A
37
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
HQ Series
Electrical Schematics 3EHQ8 & 3EHQ8M
Tapped insert
3EHQ Brown
LINE LOAD
Grn/Yel
Blue D B
A E
C
6EHQ
LINE LOAD
Case Styles
HQ1 6EHQ8 & 6EHQ8M
Tapped inserts
3A Models
C
B 0.63 Ref
16.0
D C E D
E A
A 6A Models
Grn/Yel
B
Blue Brown
B
C
HQ3
3A Models
Blue Blue
Blue
Grn/Yel
Grn/Yel B
Brown Brown
Brown
A C
D 6A Models
E
Blue
B
Grn/Yel Brown
C
38
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
HQ Series
Recommended Panel Cutout Case Dimensions
A B C D E
.235 Part No.
R .157
Dia. (2)
1
5.96 3.98
3EHQ1
.910
23.11
3EHQ3
1.295
Performance Data
3EHQ 6EHQ
db db
100 100
90 90
80 80
70 70
Common Mode / Asymmetrical (L-G)
60 60
50 50 Differential Mode / Symmetrical (L-L)
40 40
30 30
20 20
10 10
0 0
0.01 0.1 1 10 30 0.01 0.1 1 10 30
Frequency in MHz Frequency in MHz
Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line)
39
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
HT Series
6EHT3
UL Recognized
CSA Certified
VDE Approved
6EHT7
6EHT1
HT Series Specifications
• Designed to provide significant attenuation of RFI Maximum leakage current each Line to Ground:
noise in the frequency range from 10kHz to 30MHz @ 120 VAC 60 Hz: 2 A
@250 VAC 50 Hz: 5 A
• Size and cost-effective
Hipot rating (one minute):
Line to Ground: 2250 VDC
Line to Line: 1450 VDC
Rated Voltage (max): 250 VAC
Operating Frequency: 50/60 Hz
Rated Current: 3 to 15A
Operating Ambient Temperature Range
(at rated current Ir): -10°C to +40°C
In an ambient temperature (Ta) higher than +40°C
the maximum operating current (Io) is calculated as
follows: Io = Ir (85-Ta)/45
Ordering Information
6 E HT 7 M
Available Part Numbers
Suffix
M – Metric inserts (style 7 only) 3EHT1 6EHT7
Omit for standard or none 3EHT3 6EHT7M
3EHT7 10EHT1
Input / Output Style 3EHT7M 10EHT3
1 – .250 [6.3] spade terminals 6EHT1 15EHT1
3 – Wire leads 6EHT3 15EHT6
6 – Threaded bolt
7 – IEC inlet* (line side)
.250 [6.3] spade terminals
(load side)
Accessories
HT Series GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord
Current Rating
3, 6, 10 or 15A
HT Series
Electrical Schematics HT3
3 & 6EHT
LINE LOAD Blue Blue
Brown
Green/Yellow
Brown
B 1
10EHT
15EHT
LINE LOAD
HT6
Case Styles
B 2.00 ±0.01
50.80 ±0.25
A C
C
D
A
HT7 & HT7M
HT1 (15A)
B D
E D B
E
C A
2.00 ±0.01
50.80 ± 0.25 C
A
41
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
HT Series
Recommended Panel Cutout Case Dimensions
A B C D E
1.575 Part No.
0.235 40.01
R
5.96
3EHT1,
0.910 6EHT1
23.1
3EHT3,
0.157
3.98
Dia. 1.295 6EHT3
32.89
3EHT7 / 7M,
6EHT7 / 7M
10EHT1
10EHT3
15EHT1
15EHT6
Performance Data
42
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
HZ Series
UL Recognized
CSA Certified
VDE Approved 1
43
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
HZ Series
Case Styles (continued)
4EHZ1 30EHZ6
B B
C D
C D E
E A
A
6EHZ1
Case Dimensions
C D A B C D E
Part No.
E
A
3EHZ1
4EHZ1
10, 15 & 20EHZ1 6EHZ1
10EHZ1
15EHZ1
20EHZ1
B
30EHZ6
C D
E
A
44
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
Performance Data
Typical Insertion Loss
Measured in closed 50 Ohm system
1
db db db
100 100 100
90 90 90
80 80 80
70 70 70
60 60 60
50 50 50
40 40 40
30EHZ6
db
100
90
80
70
60
Common Mode / Asymmetrical (L-G)
50
40 Differential Mode / Symmetrical (L-L)
30
20
10
0
0.01 0.1 1 10 30
Frequency in MHz
45
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
IK Series
IK Series Specifications
• Excellent performance for applications with high Maximum leakage current each Line to Ground:
interference levels @120 VAC 60 Hz:
1IK & 6IK: 0.6 mA
• Designed for single or two-phase applications
16, 35 & 50IK: 1.7 mA
• Wide current range 80IK: 5.2 mA
• For small to medium sized industrial equipment, @289 VAC 50 Hz:
power converters and variable speed motors 1IK: 1.2 mA
@277 VAC 50 Hz:
• Touch safe terminals on the 6 to 60A product 6IK: 1.15 mA
provide easy connections and prevent inadvertent 16, 35 & 50IK: 3.2 mA
contact for safety in the most demanding 80IK: 9.9 mA
applications
Hipot rating (one minute):
Line to Ground: 2250 VDC
Ordering Information Line to Line: 1450 VDC
1 IK 1 C Rated Voltage (max): 1IK 6 to 80IK
Line to Ground: 289 VAC 500 VAC
Line to Line: 277 VAC 480 VAC
Suffix
C – Ground Choke (1IK1C only) Operating Frequency: 50/60 Hz
Rated Current: 1 to 80A
Input / Output Style
Operating Ambient Temperature Range
1 – .250 [6.3] spade terminals (at rated current Ir): -10°C to +40°C
10 – DIN type terminal block In an ambient temperature (Ta) higher than +40°C
16 & 35IK: DIN input / Wire leads output the maximum operating current (Io) is calculated as
50 & 80IK: DIN input / DIN output follows: Io = Ir (85-Ta)/45
IK Series
Electrical Schematic
Current Rating
1, 6, 16, 35, 50 & 80A
LINE LOAD
2
Available Part Number
1
1IK1C 6IK1 2
16IK10 35IK10
50IK10 80IK10
46
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
IK Series
Case Styles
1IK1C 16 & 35IK10
1
C
B
A F
Black
B 1.49
38.0 Brown
E
6IK1 D
B
50 & 80IK10
D C
E
C
A
A
B 2.36
60.0
E
D
47
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
IK Series
Case Dimensions
A B C D E F
Part No.
1IK1C
6IK1
16IK10
35IK10
50IK10
80IK10
Performance Data
1IK1C 6IK1
db db
100 100
90 90
80 80
70 70
60 60
50 50
40 40
30 30
20 20
10 10
0 0
0.01 0.1 1 10 30 0.1 1 10 30
Frequency in MHz Frequency in MHz
48
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
General Purpose RFI Power Line Filters – Ideal for High Impedance Load
K Series
CSA Certified
VDE Approved** 1
VK1 / EK1
K Series Specifications
• Suitable for high impedance loads Maximum leakage current each Line to Ground:
• Well suited to applications where pulsed, VK Models EK Models
@ 120 VAC 60 Hz: .5 mA .21 mA
continuous and/or intermittent RFI interference
@250 VAC 50 Hz: 1.0 mA .36 mA
is present
• EK models meet the very low leakage current Hipot rating (one minute):
Line to Ground: 2250 VDC
requirements for VDE portable equipment and
Line to Line: 1450 VDC
non-patient care medical equipment
• Available with ground line inductor (choke) Rated Voltage (max): 250 VAC
Operating Frequency: 50/60 Hz
Rated Current: 1 to 60A*
Ordering Information Operating Ambient Temperature Range
10 E K 7 M (at rated current Ir): -10°C to +40°C
In an ambient temperature (Ta) higher than +40°C
the maximum operating current (Io) is calculated as
Suffix follows: Io = Ir (85-Ta)/45
M – Metric inserts (style 7 only)
Omit for standard or none
C – Ground choke (30, 40VK6 only)
Available Part Numbers
Input / Output Style 1VK1 10VK6 2EK3
1 – .250 [6.3] spade terminals 1VK3 10VK7 3EK1
3 – Wire leads 2VK1 10VK7M 3EK3
6 – Threaded bolt 2VK3 20VK1 3EK7
7 – IEC inlet* (line side) 3VK1 20VK6 3EK7M
.250 [6.3] spade terminals 3VK3 20VK7* 5EK1
(load side) 3VK7 30VK6 5EK3
K Series 3VK7M 30VK6C 5EK7
5VK1 40VK6 5EK7M
Leakage current designation 5VK3 40VK6C 10EK1
E – Low leakage (<0.5 mA) 5VK7 60VK6 10EK3
V – Standard 5VK7M 1EK1 10EK7
10VK1 1EK3 10EK7M
Current Rating 10VK3 2EK1 20EK1
1, 2, 3, 5, 10, 20, 30, 40 or 60A
49
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
K Series
Electrical Schematics Case Styles
LINE LOAD K1 (1, 2, 3, 6, 10A)
E D B
60VK6 K1 (20A)
LINE LOAD
E D B
Accessories
A C
GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord
K3
Blue Blue
Green/Yellow
E D B
Brown Brown
20VK7
A C
20VK6
VK1/EK1
50
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
K Series
Case Styles (continued)
10VK6 60VK6
1
E D B E D B
D B
E D B
A E
C
A C
30VK6/6C & 40VK6/6C
Terminal on 30VK6C and 40VK6C only
20VK7
E A
E D B D B
2.65 ± .016
C 67.31 ± .40
2.00
50.8 .669 ± .010
16.99 ± .25
A C .512 ± .010
13.00 ± .25
51
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
K Series
Case Dimensions Recommended Panel Cutouts
A B C D E K7 & K7M Cutout (3, 5, 10A)
Part No. .235
R
.157 Dia.
5.96
1VK1, 1EK1, 3.98
2VK1, 2EK1
.910
1VK3, 1EK3, 23.1
2VK3, 2EK3
3VK1, 3EK1, 1.295
5VK1, 5EK1 32.89
1.575
3VK3, 3EK3, 40.01
5VK5, 5EK3
3VK7/7M, 20VK7 Cutout
3EK7/7M R .062 .157 Dia.
5VK7/7M, 1.60 4.0
5EK7/7M
10VK1, 1.46
10EK1 37.1
10VK3,
10EK3 1.145
10VK6
29.1
60VK6 10 10
52
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
K Series
Performance Data (continued)
Typical Insertion Loss
Measured in closed 50 Ohm system
1VK
db
100
90
2VK
db
100
90
3VK
db
100
90
5VK
db
100
90
1
80 80 80 80
70 70 70 70
53
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
MV Series
UL Recognized
CSA Certified
VDE Approved
MV Series Specifications
• Multi-purpose medical filter Maximum leakage current each Line to Ground:
• Improved Line to Ground performance @ 120 VAC 60 Hz: .07 mA
@250 VAC 50 Hz: .13 mA
• A good solution to emission or immunity problems
Hipot rating (one minute):
• Meets leakage current requirements of UL2601 for Line to Ground: 2250 VDC
health care equipment Line to Line: 1450 VDC
Rated Voltage (max): 250 VAC
Operating Frequency: 50/60 Hz
Rated Current: 3 to 20A
Operating Ambient Temperature Range
(at rated current Ir): -10°C to +40°C
In an ambient temperature (Ta) higher than +40°C
the maximum operating current (Io) is calculated as
follows: Io = Ir (85-Ta)/45
MV Series
Current Rating
3, 6, 10 or 20A
54
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
MV Series
Case Styles Performance Data
MV1 (3, 6, 10A) Typical Insertion Loss
Measured in closed 50 Ohm system
3MV
db
100
6MV
db
100
1
B 90 90
80 80
70
C E 20 20
10 10
A 0
0.1 1 10 30 0
0.1 1 10 30
Frequency in MHz Frequency in MHz
10MV 20MV
db db
100 100
90 90
80 80
70 70
60 60
50
20MV1 40
50
40
30 30
20 20
10 10
0 0
0.1 1 10 30 0.1 1 10 30
Frequency in MHz Frequency in MHz
55
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
N Series
UL Recognized
CSA Certified
VDE Approved 6VN1
10VN1
N Series Specifications
• Superior attenuation for most digital electronic Maximum leakage current each Line to Ground:
equipment over the frequency range of 10kHz to @ 120 VAC 60 Hz: 1.2 mA
30MHz @250 VAC 50 Hz: 2.0 mA
• Provides excellent common mode and differential Hipot rating (one minute):
mode performance Line to Ground: 2250 VDC
Line to Line: 1450 VDC
• Cost-effective solution to very noisy equipment
that must meet conducted emission limits Rated Voltage (max): 250 VAC
Operating Frequency: 50/60 Hz
Rated Current: 6 to 10A
Operating Ambient Temperature Range
(at rated current Ir): -10°C to +40°C
In an ambient temperature (Ta) higher than +40°C
the maximum operating current (Io) is calculated as
Ordering Information follows: Io = Ir (85-Ta)/45
10 V N 1
Electrical Schematics
Input / Output Style
1 – .250 [6.3] spade terminals 3VN
N Series LINE LOAD
Current Rating
6 or 10A
10VN
Available Part Numbers
LINE LOAD
6VN1 10VN1
56
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
N Series
Case Styles Performance Data
Typical Insertion Loss
Measured in closed 50 Ohm system
6VN
db
100
10VN
db
100
1
B 90 90
80 80
E 20
10
20
10
A 0
0.01 0.1 1 10 30 0
0.01 0.1 1 10 30
Frequency in MHz Frequency in MHz
Common Mode / Asymmetrical (L-G)
Differential Mode / Symmetrical (L-L)
57
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
Q Series
Q8
UL Recognized
CSA Certified
VDE Approved
Q1
Q3
Q Series Specifications
• Specifically developed for switching power Maximum leakage current each Line to Ground:
supplies 3 & 20A VQ Models EQ Models
• High attenuation for common and differential @120 VAC 60 Hz: .73 mA .22 mA
mode interference @250 VAC 50 Hz: 1.27 mA .38 mA
• Effective from 10kHz to 30MHz 6A
@120 VAC 60 Hz: — .29 mA
• Optimized for attenuation and size @250 VAC 50 Hz: — .51 mA
• 3 or 6A versions available with IEC inlet Hipot rating (one minute):
Line to Ground: 2250 VDC
Line to Line: 1450 VDC
Rated Voltage (max): 250 VAC
58
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
Q Series
Electrical Schematics Q8, Q8M (3A)
Tapped insert
3A Brown
LINE LOAD
1
Grn/Yel
Blue
D B
A E
C
Grn/Yel C
B 0.63
Ref
Blue Brown 16.0
.313
Ref
7.95
D C B E D
E
A 6A Models A
B
C
Case Dimensions
A B C D E
Part No.
Q3
3A Models 3VQ1, 3EQ1
Blue
Blue
Blue
Grn/Yel
3VQ3, 3EQ3
Grn/Yel B
Brown Brown
Brown
59
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
Q Series
Recommended Panel Cutout
.235 .157
R Dia. (2)
5.96 3.98
.910
23.11
1.295
32.89
1.575
40.01
Performance Data
20EQ
db
100
90
80
70
60 Common Mode / Asymmetrical (L-G)
50
Differential Mode / Symmetrical (L-L)
40
30
20
10
0
0.01 0.1 1 10 30
Frequency in MHz
60
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
R Series
VR7/7M
UL Recognized
CSA Certified
VDE Approved
VR3/ER3
R Series Specifications
• Dual T section RFI filter provides premium Maximum leakage current each Line to Ground:
performance VR Models ER Models
@120 VAC 60 Hz: .4 mA .21 mA
• Well suited for low impedance loads where noisy
@250 VAC 50 Hz: .7 mA .36 mA
RFI environments are present
• Controls pulsed, continuous and/or intermittent Hipot rating (one minute):
Line to Ground: 2250 VDC
interference
Line to Line: 1450 VDC
• ER models offer low leakage current without
deterioration of insertion loss Rated Voltage (max): 250 VAC
Operating Frequency: 50/60 Hz
Rated Current: 1 to 20A
Operating Ambient Temperature Range
Ordering Information (at rated current Ir): -10°C to +40°C
10E R 7 M In an ambient temperature (Ta) higher than +40°C
the maximum operating current (Io) is calculated as
follows: Io = Ir (85-Ta)/45
Suffix
M – Metric inserts (style 8 only)
Omit for standard or none Available Part Numbers
C – Ground choke (select models) 1VR1 1ER1
1VR3 1ER3
Input / Output Style 2VR1 2ER1
1 – .250 [6.3] spade terminals 2VR3 2ER3
3 – Wire leads 3VR1 3ER1
6 – Threaded bolt 3VR3 3ER3
7 – IEC inlet* (line side) 3VR7 3ER7
.250 [6.3] spade terminals 3VR7M 3ER7M
(load side)
5VR1 5ER1
R Series 5VR3 5ER3
5VR7 5ER7
Leakage current designation
5VR7M 5ER7M
E – Low leakage (<0.5 mA)
10VR1 10ER1
V – Standard
10VR3 10ER3
10VR6 10ER7
Current Rating
1, 2, 3, 5, 10 or 20A 10VR7 10ER7M
10VR7M 20ER1
20VR1
*IEC 60320-1 C14 inlet mates with C13 connector 20VR6
61
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
R Series
Electrical Schematic Case Styles (continued)
R3
LINE LOAD
Blue Blue
B
Brown Brown
A Green/
Yellow
D
E C
Case Styles
R1 (1, 2, 3, 5, 10A) 10VR6
B
B
D
E D
C
A C E
A
R1 (20A) 20VR6
E D B
E D B
2.00
50.8 2.00
50.8
A C
A C
62
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
R Series
Case Styles (continued) Case Dimensions
R7 & R7M A B C D E
Part No.
Tapped insert
D B
1VR1, 1ER1,
2VR1, 2ER1
1VR3, 1ER1,
1
2VR3, 2ER3
Accessories
GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord
63
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
R Series
Performance Data
Typical Insertion Loss
Measured in closed 50 Ohm system
1ER 3ER 5ER 2ER, 10ER & 20ER
db db db db
100 100 100 100
90 90 90 90
80 80 80 80
70 70 70 70
60 60 60 60
50 50 50 50
40 40 40 40
30 30 30 30
20 20 20 20
10 10 10 10
0 0 0 0
0.1 1 10 30 0.1 1 10 30 0.1 1 10 30 0.1 1 10 30
Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz
10VR 20VR
db db
100 100
90 90
80 80
70 70
Common Mode / Asymmetrical (L-G)
60 60 Differential Mode / Symmetrical (L-L)
50 50
40 40
30 30
20 20
10 10
0 0
0.1 1 10 30 0.1 1 10 30
Frequency in MHz Frequency in MHz
Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line)
64
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
RK Series
UL Recognized
CSA Certified
VDE Approved 1
Current Rating
3, 6, 10, 15 or 20A
65
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
RK Series
Case Styles Case Dimensions
A B C D E
Part No.
RK1 (3 & 6A)
3ERK1
A
E 6ERK1
C
D
10ERK1, 15ERK1,
20ERK1
A
E
C D
66
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
RK Series
Performance Data
20RK
db
100
90
80
70
60 Common Mode / Asymmetrical (L-G)
50
Differential Mode / Symmetrical (L-L)
40
30
20
10
0
0.01 0.1 1 10 30
Frequency in MHz
67
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
S Series
UL Recognized
CSA Certified
VDE Approved
20VS1
3VS1
S Series Specifications
• Combines Line to Ground interference rejection Maximum leakage current each Line to Ground:
filters with additional circuitry to reduce Line to 3 & 20A 60A
Line noise and transients @120 VAC 60 Hz: .4 mA .75 mA
@250 VAC 50 Hz: .7 mA 1.25 mA
• Designed for use when equipment impedance at
RF frequencies is high Hipot rating (one minute):
Line to Ground: 2250 VDC
• Effective for use with switch-mode power supplies
Line to Line: 1450 VDC
• Effective when used to control emissions in
equipment using SCR and T2L circuits for Rated Voltage (max): 250 VAC
compliance with FCC Part 15, Subpart J and Operating Frequency: 50/60 Hz
EN55022, Level A, down to 150kHz
Rated Current: 3 to 60A
Operating Ambient Temperature Range
(at rated current Ir): -10°C to +40°C
In an ambient temperature (Ta) higher than +40°C
Ordering Information the maximum operating current (Io) is calculated as
20 V S 6 follows: Io = Ir (85-Ta)/45
68
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
S Series
Case Styles
S1 (3, 6, 10A) 60VS6
A
E
1
B C D
.415 [10.54] ref.
E
A C 1.12 ref.
28.5
Case Dimensions
20VS1 A B C D E
Part No.
3VS1
E D B
6VS1
10VS1
2.00
50.8
A C 20VS1
20VS6
60VS6
20VS6
E
B D
2.00
50.8
C A
69
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
S Series
Performance Data
60VS
db
100
90
Common Mode / Asymmetrical (L-G)
80 Differential Mode / Symmetrical (L-L)
70
60
50
40
30
20
10
0
0.01 0.1 1 10 30
Frequency in MHz
Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line)
70
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
SB Series
UL Recognized
CSA Certified
VDE Approved
20VSB1
1
30ESB6
SB Series Specifications
• Enhanced performance version of our popular Maximum leakage current each Line to Ground:
B Series of RFI line filters VSB Models ESB Models
@ 120 VAC 60 Hz: .75 mA .22 mA
• Small size with enhanced performance
@250 VAC 50 Hz: 1.25 mA .36 mA
• 30A version half the size of other 30A filters
Hipot rating (one minute):
• Low leakage version available that meets current Line to Ground: 2250 VDC
requirements of VDE portable equipment and Line to Line: 1450 VDC
non-patient care medical equipment
Rated Voltage (max): 250 VAC
250 VDC
Ordering Information Operating Frequency: 50/60 Hz
20 E SB 6 Rated Current: 6 to 30A
Operating Ambient Temperature Range
Input / Output Style (at rated current Ir): -10°C to +40°C
1 – .250 [6.3] spade terminals In an ambient temperature (Ta) higher than +40°C
6 – Threaded bolt the maximum operating current (Io) is calculated as
follows: Io = Ir (85-Ta)/45
SB Series
Electrical Schematic
LINE LOAD
71
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
SB Series
Case Styles Case Dimensions
A B C D E
6ESB1 & 6VSB1 Part No.
6ESB1,
6VSB1
10ESB1,
B 10VSB1
10ESB6,
10VSB6
C D 20ESB1,
E 20VSB1
A 20ESB6,
20VSB6
30ESB6,
30VSB6
C D
E
A
C D
E
A
72
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
SB Series
Performance Data
Typical Insertion Loss
Measured in closed 50 Ohm system
ESB Models
1
6ESB1 10ESB1 10ESB6 20ESB1
db db db db
20ESB6 30ESB6
db db
100 100
90 90
80 80
70 70
60 60
50 50
40 40
30 30
20 20
10 10
0 0
0.01 0.1 1 10 30 0.01 0.1 1 10 30
Frequency in MHz Frequency in MHz
VSB Models
6VSB1 10VSB1 10VSB6 20VSB1
db db db db
100 100 100 100
90 90 90 90
80 80 80 80
70 70 70 70
60 60 60 60
50 50 50 50
40 40 40 40
30 30 30 30
20 20 20 20
10 10 10 10
0 0 0 0
0.01 0.1 1 10 30 0.01 0.1 1 10 30 0.01 0.1 1 10 30 0.01 0.1 1 10 30
Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz
20VSB6 30VSB6
db db
100 100
90 90
80 80
70 70
60 60
50 50
40 40
30 30
20 20
10 10
0 0
0.01 0.1 1 10 30 0.01 0.1 1 10 30
Frequency in MHz Frequency in MHz
73
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
SB Series
Performance Data (continued)
Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line)
74
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
High Performance K Series RFI Line Filters for SMPS Emission Control
SK Series
UL Recognized SK7/7M
CSA Certified
VDE Approved 1
SK1
SK Series Specifications
• Designed to reduce conducted noise to Maximum leakage current each Line to Ground:
acceptable limits for equipment that must comply 3, 6 & 10A VSK Models ESK Models
with FCC / EN specifications @120 VAC 60 Hz: .4 mA .21 mA
• Utilizes significantly higher element values than @250 VAC 50 Hz: .7 mA .36 mA
the general purpose K Series which makes them 20, 30 & 40A
better suited for equipment with Line to Ground @120 VAC 60 Hz: .75 mA .3 mA
and Line to Line conducted emissions including @250 VAC 50 Hz: 1.25 mA .5 mA
those with switching power supplies Hipot rating (one minute):
• ESK6C and VSK6C incorporate separate ground Line to Ground: 2250 VDC
circuit inductor to isolate the equipment chassis Line to Line: 1450 VDC
from power line ground at RF frequencies Rated Voltage (max): 250 VAC
Operating Frequency: 50/60 Hz
Ordering Information Rated Current: 3 to 40A
10 E SK 7 M Operating Ambient Temperature Range
(at rated current Ir): -10°C to +40°C
In an ambient temperature (Ta) higher than +40°C
Suffix
the maximum operating current (Io) is calculated as
M – Metric inserts (style 7 only) follows: Io = Ir (85-Ta)/45
Omit for standard or none
C – Ground choke (30ESK/VSK only)
Available Part Numbers
Input / Output Style
1 – .250 [6.3] spade terminals 3VSK1 3ESK1 20ESK6
3 – Wire leads 3VSK3 3ESK3 20VSK6
6 – Threaded bolt 3VSK7 3ESK7 30ESK6
7 – IEC inlet* (line side) 3VSK7M 3ESK7M 30ESK6C
.250 [6.3] spade terminals 6VSK1 6ESK1 30VSK6
(load side) 6VSK3 6ESK3 30VSK6C
SK Series 6VSK7 6ESK7 40VSK6
6VSK7M 6ESK7M
Leakage current designation 10VSK1 10ESK1
E – Low leakage (<0.5 mA) 10VSK3 10ESK3
V – Standard 10VSK7 10ESK7
10VSK7M 10ESK7M
Current Rating
3, 6, 10, 20, 30 or 40A
SK Series
Electrical Schematic Case Styles
SK1
LINE LOAD
1
B
D
E
A C
Accessories
GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord
SK3 (3A)
Blue Blue
B
Brown Brown
A Green/
Yellow
D
E C
Blue Blue
Grn/Yel
B
Brown Brown
ESK6 / VSK6
A C
D
E
76
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
SK Series
Case Styles (continued)
SK6 (20A) SK6 (40A)
D
1
B E D B
C A C
D B
E D B
A E
C
1.50
38.1
A C
E D B
.910
23.11
1.295
1.50 32.89
38.1
1.575
A C 40.01
77
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
SK Series
Case Dimensions Performance Data
A B C D E
Part No. Typical Insertion Loss
3VSK1, Measured in closed 50 Ohm system
3ESK1 3 & 6VSK 3 & 6ESK
db db
3VSK3, 100 100
78
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
SK Series
Performance Data (continued)
79
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
High Performance RFI Power Line Filters for Switching Power Supplies
T Series
UL Recognized
CSA Certified
VDE Approved
T Series Specifications
• Superior common-mode and premium Maximum leakage current each Line to Ground:
differential-mode attenuation 3, 6 & 10A ET Models VT Models
• Smaller package sizes than the EP Series @120 VAC 60 Hz: .30 mA .75 mA
@250 VAC 50 Hz: .50 mA 1.2 mA
• Size and cost-effective
15 & 20A
• ET models can help meet very low leakage @120 VAC 60 Hz: .30 mA 1.2 mA
current requirements @250 VAC 50 Hz: .50 mA 2.0 mA
Current Rating
3, 6, 10, 15 or 20A
80
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
T Series
Electrical Schematics Case Styles
3 & 6A T1 (3, 6, 10A)
LINE LOAD
B
1
15 & 20A
LINE LOAD
T1 (15 & 20A)
E D B
2.00± .01
Accessories 50.8± .25
T3
Blue Blue
Grn/Yel
B
Brown Brown
A C
D
E
81
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
T Series
Case Styles (continued) Case Dimensions
A B C D E
T6 Part No.
3ET1, 6ET1
E D B 3ET3, 6ET3
3ET7, 6ET7
2.00 ± .01
10ET1, 10VT1
50.8 ± .25
A C
10ET3, 10VT3
15ET1, 15VT1,
20ET1, 20VT1
T7 15ET6, 15VT6,
20ET6, 20VT6
Tapped insert
D B
E
A C
.910
23.1
1.295
32.89
1.575
40.01
82
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
T Series
Performance Data
Common Mode / Asymmetrical (L-G)
Typical Insertion Loss
1
Differential Mode / Symmetrical (L-L)
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line)
83
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
U Series
UL Recognized
CSA Certified
VDE Approved
6EU1 6EUP
U Series Specifications
• Designed for equipment using power factor Maximum leakage current each Line to Ground:
corrected power supplies @ 120 VAC 60 Hz: .30 mA
@250 VAC 50 Hz: .50 mA
• Offers high impedance circuit to mismatch the
power supply’s impedance characteristics Hipot rating (one minute):
• Available in PC board mountable version Line to Ground: 2250 VAC
Line to Line: 1450 VDC
• All models meet low leakage current requirements
Rated Voltage (max): 250 VAC
Operating Frequency: 50/60 Hz
Rated Current: 6A
Operating Ambient Temperature Range
(at rated current Ir): -10°C to +40°C
In an ambient temperature (Ta) higher than +40°C
the maximum operating current (Io) is calculated as
Ordering Information follows: Io = Ir (85-Ta)/45
6EU1
Current Rating
6A
84
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
U Series
Case Styles Case Dimensions
6EU1
Part No.
A
B
C
6EUP
6EU
db
100
90
80
B
70
60
50
40
30
A
Minimum Insertion Loss
Recommended PC Board Layout Common Mode / Asymmetrical (Line to Ground)
LINE LOAD
.157 Dia. (3) .075 Dia. (6)
.26
6.60
1.50 .52
38.1
.75
13.21 Differential Mode / Symmetrical (Line to Line)
19.05
1.50 .79
38.1 20.07
2.10
53.34
2.99
75.95
85
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
V and W Series
UL Recognized
CSA Certified
VV1 / VW1
VDE Approved1
VV6 / VW6
Ordering Information
20 V V 6 W Series (3, 6 & 10A)
LINE LOAD
Input / Output Style
1 – .250 [6.3] spade terminals
6 – Threaded bolt
7 – IEC inlet* (line side)
.250 [6.3] spade terminals W Series (20A)
(load side) LINE LOAD
V or W Series
Current Rating
120VW7, 20A model tested by Underwriters Laboratories
3, 6, 10 or 20A to US and Canadian requirements and is
VDE approved at 16A, 250VAC
*IEC 60320-1 C20 inlet mates with C19 connector
86
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
1
57.15
10VV1 10VW1
20VV1 20VW1
20VV6 20VW6 .047 ± .010
1.19 ± .25
20VW7* 5.33 ± .025
135.38 ± .635
B
Recommended Panel Cutout
.157
3.98 Dia. 2.30
58.42
D
E 1.22
C
1.60
30.99 L 40.46
A C
.75
19.05
2.12
53.85
A 10VV1, 10VW1
C
20VV1, 20VW1
V6 / W6
20VV6, 20VW6
20VW7
E D B
2.00
50.8
A C
*20VW7, 20A model tested by Underwriters Laboratories
to US and Canadian requirements and is
VDE approved at 16A, 250VAC
87
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
V and W Series
Performance Data
Typical Insertion Loss
Measured in closed 50 Ohm system Common Mode / Asymmetrical (L-G)
Differential Mode / Symmetrical (L-L)
Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line)
88
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
WG Series
UL Recognized
CSA Certified
VDE Approved 1
WG Series Specifications
• Cost-effective Maximum leakage current each Line to Ground:
A, B & C Models D, E & F Models
• Tubular design
@ 120 VAC 60 Hz: .76 mA .10 mA
• WGA, WGB and WGC versions designed to @250 VAC 50 Hz: 1.27 mA .20 mA
comply with leakage current for fixed appliances
Hipot rating (one minute):
not easily moved from one place to another
Line to Ground: 2250 VDC
• WGD, WGE and WGF versions designed to comply Line to Line: 1450 VDC
with leakage current requirements for appliances
Rated Voltage (max): 250 VAC
which may be easily moved from one place to
another Operating Frequency: 50/60 Hz
• Available in a variety of styles Rated Current: 16A
Operating Ambient Temperature Range
(at rated current Ir): -10°C to +40°C
In an ambient temperature (Ta) higher than +40°C
Ordering Information the maximum operating current (Io) is calculated as
follows: Io = Ir (85-Ta)/45
16 WG A 1
Electrical Schematics
Input / Output Style
1 – .250 [6.3] spade terminals L (2) U (1)
3 – Wire Leads
7 – RAST 5 connection GND
N(4) U (3)
Leakage Current & Performance
A, B & C: for fixed appliances With RAST 5 Connector (style 7)
A = Standard
L
B = Enhanced
C = High performance GND
D, E & F: for mobile appliances N
D = Standard
E = Enhanced
F = High performance Available Part Numbers
16WGA1 16WGA3 16WGA7
WG Series 16WGB1 16WGB3 16WGB7
16WGC1 16WGC3 16WGC7
Current Rating 16WGD1 16WGD3 16WGD7
16A
16WGE1 16WGE3 16WGE7
16WGF1 16WGF3 16WGF7
89
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
WG Series
Case Styles
WG_1 WG_3
.386 2.46 max.
9.80 62.5
.46 .386 2.0 max. 4.0 min.
max. 9.80 50.8 101.6
11.7
1.49 Dia.
37.8 1.49 Dia.
37.8
WG_7
.386 2.4 max.
9.80 60.96
.352
min.
8.94
1.49 Dia.
37.8
WG_7 Style
90
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
WG Series
Performance Data
16WGE 16WGF
db db
100 100
90 90
80 80
70 70 Common Mode / Asymmetrical (L-G)
60 60
50 50
Differential Mode / Symmetrical (L-L)
40 40
30 30
20 20
10 10
0 0
0.01 0.1 1 10 30 0.01 0.1 1 10 30
Frequency in MHz Frequency in MHz
Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line)
91
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
X, Y, Z Series
UL Recognized
CSA Certified XP / YP / ZP
VDE Approved
3EX1 / 3EZ1
X, Y, Z Series Specifications
• Compact chassis or PC board mountable Maximum leakage current each Line to Ground:
@ 120 VAC 60 Hz: .30 mA
• Three levels of performance
@250 VAC 50 Hz: .50 mA
• Complete filtering solution in minimal size
Hipot rating (one minute):
Line to Ground: 2250 VDC
Line to Line: 1450 VDC
X Series
Rated Voltage (max): 250 VAC
• Designed to bring most digital equipment
(including those with switching power supplies) Operating Frequency: 50/60 Hz
into compliance with FCC Part 15J, Class B Rated Current: 1 to 6A
conducted emission limits
Operating Ambient Temperature Range
Y Series (at rated current Ir): -10°C to +40°C
In an ambient temperature (Ta) higher than +40°C
• Designed to bring most digital equipment the maximum operating current (Io) is calculated as
(including those with switching power supplies) follows: Io = Ir (85-Ta)/45
into compliance with EN55022, Level A and FCC
Part 15J, Class B conducted emission limits
Electrical Schematic
Z Series LINE LOAD
• Designed to bring most digital equipment
(including those with switching power supplies)
into compliance with EN55022, Level B and FCC
Part 15J, Class B conducted emission limits
Ordering Information
3EX1
Available Part Numbers
Input / Output Style 3EXP 4EYP
1 – .250 [6.3] spade terminals 3EX1 1EZP
P – PC board pins 4EXP 2EZP
6EXP 3EZP
X, Y or Z Series 2EYP 3EZ1
3EYP
Leakage current designation
E – Low leakage (<0.5 mA)
Current Rating
1, 2, 3, 4 or 6A
92
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
Chassis & PC Board Mountable RFI Filters for Emission Control (continued)
X, Y, Z Series
Case Styles Case Dimensions
X1 & Z1 Part No.
A B C D E
B
3EXP
1
3EX1
Grounds
Line Load
B .350
side side
8.89
1.190 .700
30.23 17.78
.245
6.22
.150
3.81
93
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
Chassis & PC Board Mountable RFI Filters for Emission Control (continued)
X, Y, Z Series
Performance Data
Typical Insertion Loss
Measured in closed 50 Ohm system
94
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
Chassis & PC Board Mountable RFI Filters for Emission Control (continued)
95
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
Engineering Notes
96
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
Good
Series Series
7-180A to 16-100A
Page 113 Page 104
N ow to 2 30 A
FCD AYC
Series Better
Series
6-230A 16-200A
Page 118 to Page 108
ADT A
Series Series
3-200A Best 20-60A
Page 101 Page 98
97
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
A Series
UL Recognized
CSA Certified
VDE Approved
A Series Specifications
• For 3-phase, four wire, WYE Applications Maximum leakage current, each Line to Ground:
@ 120 VAC 60 Hz: 1.4 mA
• Filters each of the three lines plus the neutral and @ 250 VAC 50 Hz: 3.4 mA
ground line
Hipot rating (one minute):
• Both common mode and differential mode
Line to Ground: 1500 VAC
suppression from 50kHz to 30MHz Neutral to Ground: 1500 VAC
• Effective for both balanced and unbalanced loads Line to Neutral: 1450 VDC
• Ground choke included Rated Voltage (max):
• Optional end bell kits available to shield input and Phase to Phase: 440 VAC
output terminals Phase to Neutral / Ground: 250 VAC
• AYP single stage for lower noise environments Operating Frequency: 50/60 Hz
• AYT dual stage provides highest performance Rated Current: 20 to 60A
Operating Ambient Temperature Range
(at rated current Ir): -10°C to +40°C
In an ambient temperature (Ta) higher than +40°C
the maximum operating current (Io) is calculated as
Ordering Information follows: Io = Ir (85-Ta)/45
45 AYT 6 C
Electrical Schematics
Suffix
C – Ground Choke AYP6C Models
LINE LOAD
Input / Output Style A A
6 – Threaded 1/4 – 20 bolt
B B
Series designation
AYP – Single Stage
AYT – Dual Stage C C
Current Rating
N N
20, 30, 45 or 60A LINE LOAD
GND GND
98
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
A Series
Electrical Schematics (continued) Case Style
AYT6C Models
C A
LINE LOAD E
A A
B B
C C
D B
N
LINE
GND
LOAD
GND
N
2
Available Part Numbers
Accessories
Mounting bracket kit with captive nuts:
AA400: 20A & 30A versions
Case Dimensions
AA405: 45A & 60A versions
A* B C D E
AA406A Part No.
AA407A
20AYP6C
AA405 30AYP6C
AA400
Protective cover for use with mounting bracket: 45AYP6C
(For Europe only. Limited availability in other regions)
AA406A: 20A & 30A versions
60AYP6C
AA407A: 45A & 60A versions
End bell kit (bracket and cover) with captive nuts: 20AYT6C
AA406: 20A & 30A versions
AA407: 45A & 60A versions 30AYT6C
AA406 / AA407
45AYT6C
Kits includes both
bracket and cover
60AYT6C
Additional captive nuts:
AA401: 10 nuts
99
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
A Series
Performance Data
Typical Insertion Loss
Measured in closed 50 Ohm system
100
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
ADT Series
UL Recognized
ADT Series
• Designed for very high insertion loss for Delta
Specifications
Maximum leakage current at 277 VAC 60 Hz,
2
three phase, three wire applications each Line to Ground:
ADT6: 1.3 A
63ADT6 63ADT6S
100ADT6 100ADT6S C C
160ADT6 160ADT6S
200ADT6 200ADT6S
101
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
ADT Series
Electrical Schematics (continued) Case Style
A
2.00
F
100, 160 & 200 ADT6 1.00
LINE LOAD
A A
G G
B B
3/8-16 Thread
C (7x)
ADT6S H
0.75 0.75 J
LINE LOAD (2x) 0.75
A A
K
(2x) C
L C
L B
D
B B (2x)
C
L C
L
C C Line Load
Case Dimensions
A B C D E F G H J K
Part No.
63ADT6
63ADT6S
100ADT6
100ADT6S
160/200ADT6
160/200ADT6S
102
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
ADT Series
Performance Data
Typical Insertion Loss
Measured in closed 50 Ohm system
db db db db
100 100 100 100
90 90 90 90
2
80 80 80 80
70 70 70 70
60 60 60 60
50 50 50 50
40 40 40 40
30 30 30 30
20 20 20 20
10 10 10 10
0 0 0 0
0.01 0.1 1 10 100 300 0.01 0.1 1 10 100 300 0.01 0.1 1 10 100 300 0.01 0.1 1 10 100 300
Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz
db db db db
100 100 100 100
90 90 90 90
80 80 80 80
70 70 70 70
60 60 60 60
50 50 50 50
40 40 40 40
30 30 30 30
20 20 20 20
10 10 10 10
0 0 0 0
0.01 0.1 1 10 100 300 0.01 0.1 1 10 100 300 0.01 0.1 1 10 100 300 0.01 0.1 1 10 100 300
Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz
Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line)
103
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
AYA Series
UL Recognized*
25AYA6A
Current Rating
16, 25, 36, 50, 63 or 100A
104
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
AYA Series
LINE LOAD
A A A
D
B B
C
N
C
N B
2.95 ± 0.01
75.0 ± 0.3
2
GND GND
Case Style
AYA6A (Flange mount with screw terminals) 16AYA10
A C
D
4.92 ± 0.02 E
125.0 ± 0.5
B
B E
2.76 ± 0.012 C
70.0 ± 0.3
2.76 ± 0.012
70.0 ± 0.3
D
A
105
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
AYA Series
36AYA10
Case Dimensions
A B C D E*
Part No.
D
A 36AYA10
63AYA10
63AYA10
B E
4.53 ± 0.012
115.0 ± 0.3
D
A
106
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
AYA Series
Performance Data
Typical Insertion Loss Common Mode / Asymmetrical (L-G)
Measured in closed 50 Ohm system Differential Mode / Symmetrical (L-L)
16AYA 25AYA 36AYA 50AYA
db db db db
100 100 100 100
90 90 90 90
80 80 80 80
70 70 70 70
60 60 60 60
2
50 50 50 50
40 40 40 40
30 30 30 30
20 20 20 20
10 10 10 10
0 0 0 0
0.01 0.1 1 10 30 0.01 0.1 1 10 30 0.01 0.1 1 10 30 0.01 0.1 1 10 30
Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz
107
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
3-phase WYE RFI Power Line Filters for High Noise Applications
AYC Series
UL Recognized*
150AYC10B
AYC Series
LINE LOAD
Current Rating A A
16, 25, 36, 63, 80, 110,
150, 180 or 200A B B
C C
Available Part Numbers
N N
16AYC10B 110AYC10B
25AYC10B 150AYC10B GND GND
36AYC10B 150AYC10B-95
63AYC10B 180AYC10B
80AYC10B 200AYC10B *All except 200AYC10B
108
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
AYC Series
Case Styles Case Dimensions
16, 25, 36, 63AYC10B A B C D E
Part No.
16AYC10B
B D
25AYC10B
E
36AYC10B
63AYC10B
2
A
80, 110 &
Terminals
B D
Torque max.
Part No. Terminal Size lbf-in [N-m]
109
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
AYC Series
Performance Data
Typical Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line)
110
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
AYO Series
UL Recognized
CSA Certified
VDE Approved
AYO Series
• For 3-phase, four wire, WYE applications
Specifications
Maximum leakage current each Line to Ground:
2
• Filters each of the three lines plus neutral 3, 6, 10A 20A
@ 120 VAC 60 Hz: 2.0 mA 3.5 mA
LINE LOAD
111
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
AYO Series
Case Style Case Dimensions
A
D A B C D E
Part No.
B AYO Series
Performance Data
Typical Insertion Loss
Measured in closed 50 Ohm system
3AYO1 6AYO1 10AY01 20AYO1
db db db db
100 100 100 100
90 90 90 90
80 80 80 80
70 70 70 70
60 60 60 60
50 50 50 50
40 40 40 40
30 30 30 30
20 20 20 20
10 10 10 10
0 0 0 0
0.1 1 10 30 0.1 1 10 30 0.1 1 10 30 0.1 1 10 30
Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz
112
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
BCF Series
UL Recognized
VDE Approved
BCF Series
• Designed for universal applications
Specifications
Maximum leakage current each Line to Ground*:
2
• Compact book-form design @ 277 VAC 50 Hz: 30 mA
55 BCF 10
Current Rating
7, 16, 30, 42, 55, 75,
100, 130 or 180A
113
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
BCF Series
Case Style
Terminals
H Ground Line/Load
F Part No. Terminals Terminals
7BCF10, 16BCF10 M5 4mm²
G
D 30BCF10 M5 10mm²
42BCF10 M6 10mm²
A
55BCF10 M6 16mm²
75BCF10 M6 25mm²
C 100BCF10, 130BCF10 M10 50mm²
180BCF10 M10 95mm²
E
L1 L1
L2 L2
L3 L3
Case Dimensions
A B C D E F G H
Part No.
114
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
BCF Series
Performance Data
Typical Insertion Loss
Measured in closed 50 Ohm system
7BCF10 16BCF10 30BCF10 42BCF10
db db db db
100 100 100 100
90 90 90 90
80 80 80 80
70 70 70 70
60 60 60 60
50 50 50 50
40
30
20
10
0
0.01 0.1 1 10 30
40
30
20
10
0
0.01 0.1 1 10 30
40
30
20
10
0
0.01 0.1 1 10 30
40
30
20
10
0
0.01 0.1 1 10 30
2
Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz
180BCF10
db
100
Common Mode / Asymmetrical (L-G) 90
Differential Mode / Symmetrical (L-L) 80
70
60
50
40
30
20
10
0
0.01 0.1 1 10 30
Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line)
115
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
CFN Series
UL Recognized*
Electrical Schematic
L1 L1
L2 L2
L3 L3
*400CFN12 only
116
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
CFN Series
Case Style
A
D1
8.27 8.27
PE
L1 L1
L L 3.94
I O
E
2
CL L2 N A
L2 F G 4.72 B
E D
L3 L3
PE
C
2.52
D2
Case Dimensions
A B C D1 D2 E F G H
Part No.
300-600CFN12
Performance Data
Typical Insertion Loss Minimum Insertion Loss
Measured in closed 50 Ohm system Measured in closed 50 Ohm system
300-600CFN12 Common Mode / Asymmetrical (Line to Ground)
db
100
90
80
70
60
50
40
30
20
10
Differential Mode / Symmetrical (Line to Line)
0
0.01 0.1 1 10 30
Frequency in MHz
Common Mode / Asymmetrical (L-G)
Differential Mode / Symmetrical (L-L)
117
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
FCD Series
UL Recognized
6FCD10
10 – Terminal Block
FCD Series
Current Rating
6, 12, 16, 25, 36, 50, 80, 110,
150, 180 or 230A
PE PE
118
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
FCD Series
Electrical Schematics (continued) Available Part Numbers
12 to 50A FCD10 6FCD10 12FCD10B 50FCD10BS
Power line Device 12FCD10 16FCD10B 80FCD10BS
L1 L1
16FCD10 25FCD10B 110FCD10BS
L2 L2
25FCD10 36FCD10B 150FCD10BS
36FCD10 50FCD10B 150FCD10BS-95
L3 L3 50FCD10 80FCD10B 180FCD10BS
110FCD10B 230FCD10BS
PE PE
150FCD10B
150FCD10B-95
180FCD10B
2
230FCD10B
L3 L3
B D
PE PE
80 to 230A FCD10B F
L2 L2
C
L3 L3
A
80 to 150A FCD10B
50 to 150A FCD10BS
PE PE Slots: .260
6.61
FCD10BS
B D
Power line Device
L1 L1
L2 L2
F
L3 L3 E
150FCD10B-95
Terminal Block
PE PE
A
A (150FCD10B-95)
119
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
FCD Series
Case Styles (continued) Case Dimensions
180 to 230FCD10B\BS
A B C D E F
Slots: .260
Part No.
6.61 Center slot on
180 & 230A only
6FCD10
120
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
FCD Series
Performance Data (continued)
Typical Insertion Loss (continued)
Measured in closed 50 Ohm system
16FCD10 25FCD10 36FCD10 50FCD10
db db db db
100 100 100 100
90 90 90 90
80 80 80 80
70 70 70 70
60 60 60 60
50 50 50 50
2
40 40 40 40
30 30 30 30
20 20 20 20
10 10 10 10
0 0 0 0
0.01 0.1 1 10 30 0.01 0.1 1 10 30 0.01 0.1 1 10 30 0.01 0.1 1 10 30
Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz
180FCD10BS 230FCD10BS
db db
100 100
90 90
80 80
70 70
60 60
Common Mode / Asymmetrical (L-G)
50 50 Differential Mode / Symmetrical (L-L)
40 40
30 30
20 20
10 10
0 0
0.01 0.1 1 10 30 0.01 0.1 1 10 30
Frequency in MHz Frequency in MHz
121
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
FCD Series
Performance Data (continued)
Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line)
122
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
Engineering Notes
123
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
Engineering Notes
124
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .126
Selector Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .128
Power Entry Module Selector Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .129
C Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .130
CU Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .134
EBF Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .138
EC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .141
ED Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .144
EEA & EEB Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148
EAS & EBS Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148
EAH & EBH Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148
EEJ Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153
EJH & EJHS Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153
EJM & EJMS Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153
EJS Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153
EF Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .160
EJT Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .163
GG & HG Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .166
H Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .169
J Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .172
L Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .175
LA Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .180
M Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .183
3
P Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .192
125
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
Introduction
126
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
Introduction (continued)
The selector guides on the next two pages help you configure the best
power entry module for your application. Just select options from this
menu of five categories.
IEC60320-1 Socket – Common to all modules, the 60320-1 universal
socket allows your equipment to be used in every country. Simply select
a power cord with a mating IEC 60320-1 plug on one end, and a
regionally appropriate plug on the other.
Fusing Options – North American (¼” x 1¼” 3AG) or Metric
(5mm x 20mm) or both? One fuse or two?
Voltage Selection Options – 4-voltage, 2-voltage, or 1-voltage? Multitap?
Center-tap? Dual primary?
Power Switch – Yes or no? Double pole (DPST) or single (SPST)? These
power entry module switches feature international on - off markings,
current ratings up to 15A and high inrush current.
Shielding – reduce radiated emissions through the panel cut-out by
selecting a module with a shield (optional on the C, CU, M and P).
Filtering options – Choice of six filter circuits (all with low leakage current
3
to meet international standards) to fit specific filtering objectives:
• General purpose (C, CU, GG, J, LA, M and P) – most cost-effective, for
127
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
Selector Chart
Integrated IEC60320-1
Power Socket
Additional
No Features YES
Power inlet only Required? Requires switch,
with or without fuseholder and/or
filtering voltage selection
Series* Series**
EJH SRB 1-15A 1-10A
New Styles
EJT
Series
1-20A
Page 163
128
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
Medical &
C 15A 10A General
Purpose
Yes
DPST
N/A N/A
NEW
L 6A 6A General
Purpose
Optional
DPST
or
4
American
or
Metric
Medical,
General Single, North
M 6A 6A
Purpose &
Switch Mode
Power Supply
Optional
DPST
2 or
4
American
or
Metric
Medical,
General North
129
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
C Series
UL Recognized
CSA Certified
VDE Approved*
3CFS1 15CS1
C Series Specifications
• Two function power entry module combining Maximum leakage current each Line to Ground:
a DPST switch and an IEC 60320-1 inlet F Models H & Unfiltered
@ 120 VAC 60 Hz: .25 mA 2 A
• Snap–in or flange mounting @250 VAC 50 Hz: .40 mA 5 A
• Available with or without a shielded general Hipot rating (one minute):
purpose or medical grade filter Line to Ground: 2250 VDC
Line to Line: 1450 VDC
• Two element circuit provides enhanced EMI Rated Voltage: 250 VAC
attenuation
Operating Frequency: 50/60 Hz
• Reduce OEM wiring time with optional Rated Current: 1 to 15A*
pre–connected line and switch terminals
Switch: DPST
10,000 operations at 51A max. inrush
Ordering Information
.250 Terminal Push–on Force: 18 lb. / 80N (max.)
10 C F S 1
.188 Terminal Push–on Force: 15 lb. / 67N (max.)
Output Styles
1 – Spade terminals (size varies)
130
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
C Series
Electrical Schematics CE, CBE
A
F Models B
.210
5.34 F
LINE LOAD Max.
H Models
LINE LOAD
CFS, CHS 3
B Models
Note 1: Jumpers provided on CBS and CBE versions only.
Note
2: Location of optional filter
Case Styles
CS, CBS CFE, CHE
.210 Max.
B 5.34
A
C
.210
5.34
F Max.
B
A
131
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
C Series
Case Styles (continued) Case Dimensions
132
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
C Series
Performance Data
Typical Insertion Loss
Measured in closed 50 Ohm system
1CF 3CF 6CF 10CF
db db db db
100 100 100 100
90 90 90 90
80 80 80 80
70 70 70 70
60 60 60 60
50 50 50 50
40 40 40 40
30 30 30 30
20 20 20 20
10 10 10 10
0 0 0 0
0.1 1 10 30 0.1 1 10 30 0.1 1 10 30 0.1 1 10 30
Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz
Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line)
133
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
CU Series
UL Recognized
CSA Certified
VDE Approved*
6CUFS1
15CUE1
CU Series Specifications
• Designed for popular 1U (1 ¾”) height rack Maximum leakage current each Line to Ground:
mounted equipment Filtered Unfiltered
@ 120 VAC 60 Hz: .25 mA 2 A
• Two function power entry module combining @250 VAC 50 Hz: .40 mA 5 A
a SPST switch and an IEC 60320-1 inlet Hipot rating (one minute):
• Snap–in, flange and flush mounting Line to Ground: 2250 VDC
Line to Line: 1450 VDC
• Reduce OEM wiring time with optional Operating Voltage: 120/250 VAC
pre–connected line and switch terminals
Operating Frequency: 50/60 Hz
Ordering Information Rated Current: 1 to 15A*
15 CU 10 B S 1 Switch: 50A inrush capable SPST
Terminal Push–on Force: 15 lb. / 67N (max.)
Output Styles
1 – .187 [4.8] spade terminals
Mounting Styles
E – Flange Mount (Horizontal) Available Part Numbers
F – Flush Mount (Filtered only)
Filtered Versions
S – Snap–in
1CUFE1 1CUFF1 1CUFS1
Filter Type or Terminal Option 3CUFE1 3CUFF1 3CUFS1
F – General purpose 6CUFE1 6CUFF1 6CUFS1
B – No filter, includes 10CUFE1 10CUFF1 10CUFS1
pre–connected terminals 15CUFE1 15CUFF1 15CUFS1
Omit if none Non–filtered Versions
Standard Terminals Pre-connected Terminals
Side Snap–in Option 15CUE1 15CUBE1
Non-filtered versions only 15CUS1 15CUBS1
10 – Side snaps 1.0mm max. panel 15CU10S1 15CU10BS1
15 – Side snaps 1.5mm max. panel 15CU15S1 15CU15BS1
Omit for none or
standard configuration
CU Series
*15A versions are tested by Underwriters Laboratories
Current Rating to US and Canadian requirements and are
VDE approved at 10A, 250VAC
1, 3, 6, 10 or 15A
134
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
CU Series
Electrical Schematic CUFS1
LINE LOAD
Case Styles A B
CUFE1
C
CUE1 3
F B
CUS1
F B
A
C
A B
135
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
CU Series
Case Styles (continued) Case Dimensions
A B C D E F
CU10S1 & CU15S1 Part No.
CUFE1
C
CUFF1
CUFS1
A B CUE1,
CUBE1
CUS1,
CUBS1
10CUS1,
10CUBS1
15CUS1,
CUBE1 Pre-Connected Terminals 15CUBS1
R. Max D
CU10BS1 & CU15BS1
Pre-Connected Terminals
Accessories
GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord
136
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
CU Series
Performance Data
Typical Insertion Loss
Measured in closed 50 Ohm system
15CUF
db
100
90
3
80
70 Common Mode / Asymmetrical (L-G)
Differential Mode / Symmetrical (L-L)
Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line)
137
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
EBF Series
UL Recognized
CSA Certified
VDE Approved
EBF1
EBF4
138
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
EBF Series
Case Styles Case Dimensions
EBF1
A B C D E
Part No.
C
EBF1
D
E
A B EBF4
EBF4
E
D
A B
Recommended Panel Cutout
3
.14 Dia.
1.40 3.6
35.6
1.575 ± .004
40.0 ± 0.1 .20
R Typ.
5.1
139
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
EBF Series
Performance Data
Typical Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line)
140
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
EC Series
EC8
UL Recognized
CSA Certified
VDE Approved
EC2
EC4
EC1
EC Series Specifications
• Three element differential mode circuit provides Maximum leakage current each Line to Ground:
the highest attenuation of any available standard @ 120 VAC 60 Hz: .25 mA
inlet filter @250 VAC 50 Hz: .50 mA
3
• High common mode inductance Hipot rating (one minute):
• High differential mode capacitance Line to Ground: 2250 VDC
Line to Line: 1450 VDC
• Effective attenuation of Line to Ground and Line
to Line noise across the frequency range Rated Voltage (max.): 250 VAC
• Performance and application similar to the ED Operating Frequency: 50/60 Hz
EC Series
Current Rating
1, 3, 6, or 10A Available Part Numbers
141
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
EC Series
Case Styles Case Dimensions
EC1
Part A B C D E F
C No.
EC1
D A B
E
EC2
EC2 EC4
C EC8
.65 Max.
16.5
D
E A B
C 1.575 1.575
40.01 .062 40.01 .234
R. R.
1.58 5.94
Typ. Typ.
Green/Yellow
Blue
D
E A
B
F
Accessories
GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord
F
EC8
F
Blue
Green/Yellow
D E B
Brown FA601: Insulating Shroud
.413 Dia.
F 10.5
.271 Dia.
6.9
A
.118
3.0
1.39
35.4
C
1.17 .767
29.7 19.5
142
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
EC Series
Performance Data
3
0 0 0 0
0.1 1 10 30 0.1 1 10 30 0.1 1 10 30 0.1 1 10 30
Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz
Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line)
143
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
ED Series
ED2
UL Recognized
CSA Certified
ED1 / ED1C
VDE Approved*
EC4 / ED4C
EC8 / ED8C
ED Series Specifications
• Two element circuit provides medium attenuation Maximum leakage current each Line to Ground:
• Available with an internal ground-circuit inductor @ 120 VAC 60 Hz: .22 mA
(C versions) to isolate equipment chassis from @250 VAC 50 Hz: .38 mA
power line ground at radio frequencies Hipot rating (one minute):
• Versions up to 15A* Line to Ground: 2250 VDC
Line to Line: 1450 VDC
• Similar to EEJ Series with alternative termination
options Rated Voltage (max.): 250 VAC
• See the EC Series for better differential mode Operating Frequency: 50/60 Hz
performance Rated Current: 1 to 15A*
Operating Ambient Temperature Range
(at rated current Ir): -10°C to +40°C
In an ambient temperature (Ta) higher than +40°C
Ordering Information the maximum operating current (Io) is calculated as
3 ED 1 C follows: Io = Ir (85-Ta)/45
144
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
ED Series
Case Styles
A
C
3
ED2
Case Dimensions
Blue
D
6ED8C
E A
B
F 10ED1 /1C,
15ED1
15ED8
F
145
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
ED Series
Recommended Panel Cutouts Accessories
Front Mount Back Mount
GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord
.820 .900
20.8 22.9
.140 .140
1.200 3.56 1.200 3.56
30.48 30.48
1.575 1.575
40.01 .062 40.01 .234
R. R.
1.58 5.94
Typ. Typ.
.118
3.0
1.39
35.4
1.17 .767
29.7 19.5
Performance Data
Typical Insertion Loss
Measured in closed 50 Ohm system
1ED 3ED 6ED 6ED1C
db db db db
100 100 100 100
90 90 90 90
80 80 80 80
70 70 70 70
60 60 60 60
50 50 50 50
40 40 40 40
30 30 30 30
20 20 20 20
10 10 10 10
0 0 0 0
0.1 1 10 100 0.1 1 10 100 0.1 1 10 30 0.1 1 10 30
Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz
146
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
ED Series
Performance Data (continued)
Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line)
3
147
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
UL Recognized
CSA Certified EEA1 / EEB1
VDE Approved
EEA2 / EEB2
EEAP / EEBP
148
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
.118
3.0 EAS / EBS
1.39
35.4
1.17 .767
29.7 19.5
149
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
.820 .900
.50
Max. 20.8 22.9
12.7
D A B 1.14*
.140
.140
3.56 1.200 3.56
28.96*
E 30.48
1.575 1.575
40.01 .12 40.01 .234 R.
R.
*± 0.02 [0.51]
3.05
Typ. 5.94 Typ.
E A B
R 0.188 [4.78]
(4X)
PC Board Layout
EAS1 & EBS1 0.075
1.91 ∅
.81
C Max.
20.5
0.520
13.21
D
E A B
0.551
.685*
13.99
17.40*
*±.015 [0.38]
150
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
EAH Models
1A 3A 6A 10A
db db db db
100 100 100 100
90 90 90 90
80 80 80 80
70 70 70 70
60 60 60 60
50 50 50 50
40 40 40 40
30 30 30 30
20 20 20 20
10 10 10 10
0 0 0 0
0.1 1 10 30 0.1 1 10 30 0.1 1 10 30 0.1 1 10 30
Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz
EBH Models
1A 3A 6A 10A
db db db db
100 100 100 100
90 90 90 90
80 80 80 80
70 70 70 70
60 60 60 60
50 50 50 50
40 40 40 40
30 30 30 30
20 20 20 20
10 10 10 10
0 0 0 0
0.1 1 10 30 0.1 1 10 30 0.1 1 10 30 0.1 1 10 30
Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz
151
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line)
152
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
EEJ Series
Including the EJH/EJHS, EJM/EJMS and EJS Models
UL Recognized
CSA Certified
20EJH1
VDE Approved*
3EEJ1
20EEJ8
153
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
154
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
Case Styles
EEJ1, EJH1 & EJM1 (1-15A) EEJ8, EJH8 & EJM8 (1-15A)
Blue
C
Green/Yellow
D E B
Brown
D B
E A
A
0.96
max.
24.39
C
Blue
Green/Yellow
D E B
Brown
C 0.96
max.
24.39
C
D A B
E
C
C
D
E A B D
E A B
155
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
C F .140 .140
1.200 3.56
∅ 1.200 ∅
3.56
30.48 30.48
1.575 1.575
40.01 .12 .234 R.
D A B 3.05
R. 40.01
Typ. 5.94 Typ.
E
Tolerances ± .005 [0.13] unless otherwise noted
20A EEJ & EJH
Front Mount Back Mount
1.055 .985
20EEJ8 & 20EJH8 26.8 25.02
.138 .138
C 1.370 3.51
∅ 1.300 ∅
3.51
34.8 33.0
1.654 1.654
42.0 .118 42.0 .125 R.
Blue
R.
3.0 3.18 Typ.
Typ.
Green/Yellow
D E B F Tolerances ± .005 [0.13] unless otherwise noted
Brown
0.815
20.70
Tolerance ±.002 [.050]
20A EJS
1.450 0.125
20EJS8 36.83
R
3.175
Max.
C
1.053
Blue
26.75
D E
Green/Yellow
B F
Brown
PC Board Layout
A
0.075
1.91 ∅
0.520
13.21
0.551
13.99
.685*
17.40*
*±.015 [0.38]
156
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
70 70
EEJ8, EJH8 80 80
EJMS8
20EEJ1,
15A 20A
20EJH1
db db
100 100
20EJS1 90 90
80 80
20EJS8 20 20
20EJS1 3EJS1
157
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
15A 20A
db db
100 100
90 90
80 80
70 70
60 60
50 50
40 40
30 30
20 20
10 10
0 0
0.1 1 10 30 0.1 1 10 30
Frequency in MHz Frequency in MHz
15A
db
100
90
80
70
60
50
Common Mode / Asymmetrical (L-G)
40 Differential Mode / Symmetrical (L-L)
30
20
10
0
0.01 0.1 1 10 30
Frequency in MHz
158
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line)
3
EJM1
EJMS1
159
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
EF Series
EF8
UL Recognized
CSA Certified
EF1F / EF1FC
VDE Approved*
EF4
EF2F
EF Series Specifications
• Compact single stage EMI filter with IEC 60320-1 Maximum leakage current each Line to Ground:
C14 inlet @ 120 VAC 60 Hz: .21 mA
• Two element circuit provides basic attenuation @250 VAC 50 Hz: .36 mA
• Available with an internal ground-circuit inductor Hipot rating (one minute):
(C suffix versions) to isolate equipment chassis Line to Ground: 2250 VDC
from power line ground at radio frequencies Line to Line: 1450 VDC
• Superseded by the EEA Series Rated Voltage (max.): 250 VAC
Operating Frequency: 50/60 Hz
Ordering Information Rated Current: 1 to 15A*
3 EF 1F C Operating Ambient Temperature Range
(at rated current Ir): -10°C to +40°C
Ground Circuit Inductor In an ambient temperature (Ta) higher than +40°C
Omit if none the maximum operating current (Io) is calculated as
follows: Io = Ir (85-Ta)/45
Output Styles
Accessories
1F – .250 [6.3] spade terminals
(back) GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord
2F – .250 [6.3] spade terminals
(bottom)
4 – Wire leads (bottom)
8 – Wire leads (back)
EF Series
FA601: Insulating Shroud
Current Rating .413 Dia.
1, 3, 6, 10 or 15A 10.5
.271 Dia.
6.9
160
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
EF Series
Electrical Schematic
LINE LOAD EF8
1
F
Blue
Green/Yellow
D E B
Brown
F
Note 1: C Suffix (Ground Choke) Versions only
A
Case Styles
EF1F & EF1FC C
C
D
E
A B
3
Case Dimensions
C
Recommended Panel Cutouts
Green/Yellow
Blue
D
E A .820 .900
20.8 22.9
B
F .140 .140
1.200 3.56 1.200 3.56
30.48 30.48
1.575 1.575
40.01 .062 40.01 .234
R. R.
1.58 5.94
Typ. Typ.
161
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
EF Series
Performance Data
Typical Insertion Loss
Measured in closed 50 Ohm system
1EF 3EF 6EF 10EF
db db db db
100 100 100 100
90 90 90 90
80 80 80 80
70 70 70 70
60 60 60 60
50 50 50 50
40 40 40 40
30 30 30 30
20 20 20 20
10 10 10 10
0 0 0 0
0.1 1 10 30 0.1 1 10 30 0.1 1 10 30 0.1 1 10 30
Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz
15EF
db
100
90
80
70
60 Common Mode / Asymmetrical (L-G)
50
40
Differential Mode / Symmetrical (L-L)
30
20
10
0
0.01 0.1 1 10 30
Frequency in MHz
162
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
EJT Series
UL Recognized
CSA Certified
VDE Approved*
EJT1 EJT8
EJT Series
Accessories
Current Rating GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord
1, 3, 6, 10, 15 or 20A
.118
3.0
1.39
35.4
*15A versions are tested by Underwriters Laboratories
to US and Canadian requirements and are 1.17 .767
VDE approved at 10A, 250VAC. 29.7 19.5
163
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
EJT Series
Electrical Schematics 20EJT8
LINE LOAD
Blue
1 Green/Yellow
D E Brown
B
A
Note 1: 20A Versions only
Case Styles C
EJT1
C
B
D
E A Case Dimensions
A B C D E
Part No.
EJT1
20EJT1
EJT8
C
20EJT1
B
D 20EJT8
E A
Recommended Panel Cutouts
1.575 1.654
40.00 42.01
Blue
1.20 1.370
Green/Yellow 30.48 34.80
D E B
Brown
.820 1.055
20.83 26.80
164
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
EJT Series
Performance Data
Typical Insertion Loss
Measured in closed 50 Ohm system
1EJT 3EJT 6EJT 10EJT
db db db db
100 100 100 100
90 90 90 90
80 80 80 80
70 70 70 70
60 60 60 60
50 50 50 50
40 40 40 40
30 30 30 30
20 20 20 20
10 10 10 10
0 0 0 0
0.1 1 10 100 1000 0.1 1 10 100 1000 0.1 1 10 100 1000 0.1 1 10 100 1000
Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz
15EJT
db
100
90
20EJT
db
100
90
3
80 80
70 70
Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line)
165
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
GG & HG Series
UL Recognized
CSA Certified
VDE Approved
GG1
GG8
GG Series Specifications
• Power entry module with enhanced EMI filter Maximum leakage current each Line to Ground:
• Single or dual fusing HG Models GG Models
@ 120 VAC 60 Hz: 2 A .25 mA
• Two element circuit provides basic attenuation @250 VAC 50 Hz: 5 A .42 mA
• Available with an internal ground-circuit inductor
Hipot rating (one minute):
(C versions) to isolate equipment chassis from
Line to Ground: 2250 VDC
power line ground at radio frequencies Line to Line: 1450 VDC
• Multiple termination and mounting styles
Rated Voltage (max.): 250 VAC
Operating Frequency: 50/60 Hz
HG Series
Rated Current: 1 to 10A
• Medical version of our GG Series
• Mechanically identical to GG Series Required Fuse(s): 5 x 20mm
(not included)
• Available only with dual fusing
Ordering Information
3 E GG 1 C -2 Available Part Numbers
Metric Fuse Holders Filtered modules
1 – Single
1EGG1-1 3EGG1-1 6EGG1-1 10EGG1-1
2 – Double
1EGG1-2 3EGG1-2 6EGG1-2 10EGG1-2
1EGG8-1 3EGG8-1 6EGG8-1 10EGG8-1
Ground Circuit Inductor
Omit if none 1EGG8-2 3EGG8-2 6EGG8-2 10EGG8-2
1EGS1-1 3EGS1-1 6EGS1-1 10EGS1-1
Output Styles 1EGS1-2 3EGS1-2 6EGS1-2 10EGS1-2
1 – .250 [6.3] spade terminals Filtered modules with ground circuit inductor
8 – Wire leads 1EGG1C-1 3EGG1C-1 6EGG1C-1
1EGG1C-2 3EGG1C-2 6EGG1C-2
GG or HG Series (Flange mount) 1EGG8C-1 3EGG8C-1 6EGG8C-1
GGS or HGS Series (Snap-in mount) 1EGG8C-2 3EGG8C-2 6EGG8C-2
Medical filter modules
Leakage current designation
1EHG1-2 3EHG1-2 6EHG1-2 10EHG1-2
E – Low leakage (<0.5 mA)
1EHG8-2 3EHG8-2 6EHG8-2 10EHG8-2
1EHGS1-2 3EHGS1-2 6EHGS1-2 10EHGS1-2
Current Rating
1, 3, 6 or 10A
166
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
GG & HG Series
Electrical Schematic GG8 & HG8
LINE LOAD
1
Blue
2 3 Green/Yellow
D E B
Brown
3
A
Note 1: Second fuse only in -2 version
Note 2: C versions only
Note 3: not present in HG versions
C
Accessories
GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord
3
Case Dimensions
Recommended Panel Cutouts
GG / HG GS / HGS
1.14 1.24
29.0 31.5
GS1 & HGS1
1.30 1.29
33.0 32.8
D C
1.417
E A B 36.0
167
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
GG & HG Series
Performance Data
Typical Insertion Loss Measured in closed 50 Ohm system
GG & GS Models
1A 3A 6A 10A
db db db db
100 100 100 100
90 90 90 90
80 80 80 80
70 70 70 70
60 60 60 60
50 50 50 50
40 40 40 40
30 30 30 30
20 20 20 20
10 10 10 10
0 0 0 0
0.1 1 10 30 0.1 1 10 30 0.1 1 10 30 0.01 0.1 1 10 30
Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz
3A GG1C 6A GG1C
db db
100 100
90 90
80 80
70 70
60 60
Common Mode / Asymmetrical (L-G)
50 50 Differential Mode / Symmetrical (L-L)
40 40
30 30
20 20
10 10
0 0
0.1 1 10 30 0.1 1 10 30
Frequency in MHz Frequency in MHz
HG Models
1A 3A 6A 10A
db db db db
100 100 100 100
90 90 90 90
80 80 80 80
70 70 70 70
60 60 60 60
50 50 50 50
40 40 40 40
30 30 30 30
20 20 20 20
10 10 10 10
0 0 0 0
0.1 1 10 30 0.1 1 10 30 0.1 1 10 30 0.1 1 10 30
Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz
H Series
UL Recognized EH8
CSA Certified EH9
VDE Approved*
EH4
EH1 EH5
H Series Specifications
• Minimal leakage current suitable for medical Maximum leakage current each Line to Ground:
equipment @ 120 VAC 60 Hz: 2 A
• Two element circuit provides basic EMI @250 VAC 50 Hz: 5 A
3
attenuation above 1 MHz Hipot rating (one minute):
• Available with an internal ground circuit inductor Line to Ground: 2250 VDC
(C suffix versions) to isolate equipment chassis Line to Line: 1450 VDC
from power line ground at radio frequencies Rated Voltage (max.): 250 VAC
• Flanged mounting the same as the EC, ED and EF Operating Frequency: 50/60 Hz
H Series
Case Styles H5
H1 (Chassis Mount)
C
Green/Yellow
Brown
Blue
D
E B D
E A
B
F
A C
F
H3 (Chassis Mount) H8
F
Blue
E D B D E
Green/Yellow
B
Brown
A C
C
D A B
E
Recommended Panel Cutouts
Front Mount Back Mount
.820 .900
20.8 22.9
H9 .140 .140
1.200 3.56 1.200 3.56
30.48 30.48
1.575 1.575
C 40.01 .062
R. 40.01 .234
1.58 R.
Typ. 5.94
Typ.
D
E A B
170
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
H Series
Case Dimensions Performance Data
A B C D E F Typical Insertion Loss
Part No.
Measured in closed 50 Ohm system
3EH 6EH
H1
db
100
db
100
6EH4 50 50
H8 60 60
.271 Dia.
6.9
.118
3.0
1.39
35.4
1.17 .767
29.7 19.5
171
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
J Series
6HJ4
J Series Specifications
• Power entry module with North American style Maximum leakage current each Line to Ground:
3AG fuse holder 6HJ4 or
• 2 or 4 voltage selection 6J4 Models non–filtered
@250 VAC 50 Hz: 500 A 5 A
• Compact snap-in design
Hipot rating (one minute):
• Two element circuit provides basic
Line to Ground: 1550 VAC
EMI attenuation Line to Line: 1450 VDC
• Available with minimal leakage current suitable
Operating Voltage:
for medical applications (HJ models) suffix - 1 or - 4 models: 100, 120, 220 or 240VAC
• Also available without filter (VJ models) suffix - 2 models: 115 or 230 VAC
Operating Frequency: 50/60 Hz
Rated Current: 6A
Ordering Information
Required Fuse: .25 x 1.25
(not included)
6 H J 4 -4
Available Voltage Selections
1 - Four (non–filtered versions)
2 – Two
4 or blank – Four (filtered versions)
Filtered Indicator
1 – Non–filtered
4 – Filtered
Available Part Numbers
J Series
Non–filtered models
Filter Type 6VJ1 6VJ1-2
H – Medical General Purpose Filters
V – Non-filtered
Blank – general purpose 6J4 6J4-2
Medical Filters
Current Rating
6A 6HJ4-4 6HJ4-2
172
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
J Series
Electrical Schematics Accessories
6VJ1 & 6VJ1-2 GA400:NEMA 5-15P to IEC 60320-1 C-13 line cord
Note 3
120V 220V
Note 2 100V 240V
Hot A A
S R Power On/Off 20V
Off B B
100V
H
On J C
Ground Pilot
light D D
120V
K E
Note 2 M
L F
Neutral
P N
Note 1
Transformer JA302: 2 Voltage Select Card
primary
Comes standard with 6VJ1-2, 6J4-2 and
6J4 & 6J4-2 6HJ4-2
Note 3
120V 220V
100V 240V
JA304: 4 Voltage Select Card
A A
20V
3
Power On-Off
B B
Comes standard with 6VJ1, 6J4 and 6HJ4-4
Hot Off 100V
C C
Ground On Pilot JA403: Mounting clips for .105 - .125” panels
light D D
120V
E E
Neutral J
JA410-419: Equipment Rating Labels
H F F
Open cover door and slide fuse-pull lever to left. JA500: Voltage Selector Card Extractor Tool
Select operating voltage by orienting voltage selec-
tion card with the desired voltage on top left side.
Push card firmly into module slot. Slide fuse-pull lever
to right into normal position and re-insert fuse into
holders.
Use caution in selecting correct fuse value.
173
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
J Series
Case Styles Case Dimensions
A B C D
Non-filtered Models Part No.
Performance Data
Typical Insertion Loss
Measured in closed 50 Ohm system
A D 10 10
0 0
B 0.1 1 10 30
Frequency in MHz
0.1 1 10 30
Frequency in MHz
Bezel
2.60*
Clearance 66.0 *± .003 [.076]
2.68
68.1
3.00
76.2
174
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
L Series
UL Recognized
CSA Certified
VDE Approved
EDL4C / EHL4C
EDL1S / EHL1S
L Series Specifications
• Power entry module with switch or fuse Maximum leakage current each Line to Ground:
• For 10A capability and high performance filtering DL Models HL Models
see the P Series on page 192 @ 120 VAC 60 Hz: .25 mA 2 A
@ 250 VAC 50 Hz: .50 mA 5 A
• Two element circuit provides extended EMI
attenuation similar to EAB inlet filter
• North American or metric fuse holders
Hipot rating (one minute):
Line to Ground:
Line to Line:
2250 VDC
1450 VDC
3
• Available with minimal leakage current for medical
applications (HL models) Operating Voltage:
L Series
Filter Type
D – General Purpose
H – Medical
omit for none
Current Rating
2, 4 or 6A
175
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
L Series
North American Fusing Metric Fusing
Available Part Numbers
Flange Mount Snap-In Flange Mount Snap-In
Single Voltage,
Switched 6EL1S 6EL1SC 6EL1SM 6EL1SCM
Non-Filtered
4 Voltage Select,
No Switch 6EL4 6EL4C 6EL4M 6EL4CM
Single Voltage,
Switched 4EDL1S 4EDL1SC 4EDL1SM 4EDL1SCM
4 Voltage Select,
No Switch 4EDL4 4EDL4C 4EDL4M 4EDL4CM
Single Voltage,
Switched 6EHL1S 6EHL1SC 6EHL1SM 6EHL1SCM
Medical Filter
4 Voltage Select,
No Switch 6EHL4 6EHL4C 6EHL4M 6EHL4CM
(1)
2.201*
(3) (3)
55.91
(2) 2.213*
.020 56.21
(4) R
.508
1.122*
*+.008 -.00
28.50 +.203 -.00
176
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
L Series
Electrical Schematics Accessories
GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord
DL Models
Single Voltage, Switched (DL1S)
Customer
Note 2 Transformer
Note 1 H On/Off Primaries
Neutral
2 1
Ground (1) (1a)
(2) (2a)
4 3 Device
Hot LA303: Voltage Select Wheel, 3 position
G
Selection drum for use with L4 models.
Marked with 110V, 220V and 240V
4 Voltage Select, No-Switch (DL4)
Customer
LA304: Voltage Select Wheel, 4 position
Hot
Note 1 G
Note 2
On/Off
120V
100V
B
220V Transformer
240V Primaries
B
A
B
20V
Selection drum for use with L4 models.
Marked with 100V, 110V, 220V and 240V.
One LA304 comes standard with each L4 model.
3
100V
C C C
Ground
F F F
Neutral
H
HL Models
LA400: Blank insert
Single Voltage, Switched (HL1S)
Blank to replace switch in single voltage models
Customer
Note 2 Transformer
Note 1 H On/Off Primaries LA601: Insulating Boot
Neutral
2 1 Plastic shroud to cover back of module to prevent
Ground (1) (1a)
inadvertent access
(2) (2a)
4 3 Device
Hot
F F F
Neutral
H
177
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
L Series
Case Styles
Flange Models, Non-filtered Snap-in Models, Non-filtered
3 4 A C E
1 2 B D F
G H
G H
C D C D
F
B F
.221
.221 A E
A 5.61 E 5.61
F
F
B .221
.221 A E
A 5.61 E 5.61
Case Dimensions
A B C D E F
Model No.
178
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
L Series
Performance Data
Typical Insertion Loss
Measured in closed 50 Ohm system
6EHL
db
100
3
90
80
Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line)
179
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
LA Series
UL Recognized
CSA Certified
LA Series Specifications
• Power entry module with extended and enhanced Maximum leakage current each Line to Ground:
low frequency filters XLA or
• North American or dual metric fuse holder options FLA Model ZLA Model
@120 VAC 60 Hz: .25 mA .30 mA
• DPST on/off switch @250 VAC 50 Hz: .50 mA .50 mA
• 120/240V voltage selection Hipot rating (one minute):
• The F version provides basic performance two Line to Ground: 2250 VDC
element circuit filter Line to Line: 1450 VDC
• The X version provides a three element differential Rated Voltage (max.): 250 VAC
mode circuit with extended EMI attenuation,
Operating Frequency: 50/60 Hz
suitable for meeting FCC Part 15J, Class B
conducted emissions limits Rated Current: 3 to 5A
• The Z version provides a three element differential
Required Fuse(s): one .25 x 1.25”(not included)
mode circuit with enhanced EMI low frequency
or two 5 x 20mm (not included)
attenuation, suitable for meeting EN55022 Level B
as well as FCC Part 15J limits Switch: DPST
10,000 operations at 51A max. inrush
Ordering Information
5 E F LA 2S
Case Style
2S - IEC inlet*, selectable fuse Available Part Numbers
holder, DPST switch,
spade terminals
LA Series 5EFLA2S
3EXLA2S
Filter Type 3EZLA2S
F – General purpose
X – High performance
Z – Premium performance
Current Rating
3A or 5A
*IEC 60320-1 C14 inlet mates with C13 connector
180
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
LA Series
Voltage Selection Case Styles
A
To change selected voltage: remove the fuse F
cartridge using a small blade screwdriver or similar B
tool; select the desired voltage by matching the
arrow on the fuse cartridge to the arrow located on
the front of the unit (lower right corner); replace the C D
fuse cartridge making sure the voltage selection B C
A
arrow aligns with the arrow located on the front of D E F
the unit.
E
Changing Fuses
Remove the fuse cartridge using a small blade screw-
driver or similar tool; for Metric fusing pull out the
sliding fuse covers located at the top of each fuse
compartment; insert desired fuses; push the sliding
fuse covers back in place and insert the fuse
cartridge back into the unit making sure the voltage
selection arrow aligns with the arrow located on the
Case Dimensions
3
front of the unit. (Note: Single North American or A B C D E F
Metric fuse placement is always on the side of the
Part No.
Power on/off A A
120V
Neutral
B B Recommended Panel Cutout
C
Ground
D D
E E .093R
120V
F F 2.36
Phase
G
Customer
Transformer
Primaries
2.42*
XLA & ZLA Model .140 Dia.
61.47
181
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
LA Series
Performance Data
Typical Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line)
182
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
M Series
UL Recognized
CSA Certified
VDE Approved
XM / ZM
VM
M Series
Specifications Accessories
Maximum leakage current each Line to Ground: GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord
HM FM XM/ZM
@ 120 VAC 60 Hz: 2 A .25 mA .30 mA
@250 VAC 50 Hz: 5 A .50 mA .50 mA
Hipot rating (one minute):
Line to Ground: 2250 VDC
Line to Line: 1450 VDC
Line to Load (switch off) non-filtered: 2500 VAC
Rated Voltage (max.): 250VAC
MA100: Power interconnect assembly
Operating Frequency: 50/60 Hz
For voltage select models. 8.5” wire leads
Rated Current @ 120 VAC: 3 to 6A
Rated Current @ 250 VAC:
3A models: 2A
5A models: 4A
6A Switched models: 5A
6A non-switched models: 6A
Required Fuse(s): Reversible fuseholder accepts MA101: Plug only
one .25 x 1.25” (not included) MA102: Strip of 100 pins for use with MA101
or two 5 x 20mm (not included)
MA104: Individual pins for use with MA101
Switch: DPST
100,000 operations at 70A max. inrush
MA302: Two Voltage Selection Card
Marked 120V/240V. One card comes standard with
every 2 voltage M series module
MA304: Four Voltage Selection Card
Marked 100V/120V/230V/240V. One card comes
standard with every 4 voltage M series module
Available Part Numbers
Non-Filtered Models
3 2
Voltage
2
Selections
2 6VM2 6VM2S
0
1 3EZM1S
4 3EZM4 3EZM4S
184
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
M Series
Accessories (continued) Fuse Installation Instructions
MA601 - 604: Insulating Boot
Plastic shroud for back of M series to prevent
inadvertent access to connections
1. Remove power cord
3
A Section A-A
7. Replace cover, and verify that indicator pin shows 5. Install one (1) AG fuse or two (2) metric fuses (see below)
the desired voltage 6. Replace fuse holder into housing
7. Swing and push to snap door back in place
3 2 4 2
2
Fuse Options
1
0
0
4
2 3
0
0
1
1 0 0 1 2 0
100V 120V
1
0 0
0
1
0
0
2 3 0 2 4 0
Install fuses on one side only, do not install
230V 240V both AG and metric fuses at the same time
185
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
M Series
Electrical Schematics
Non-Filtered Models Filtered Models
VM1 FM1 & HM1
Power On/Off
Power On/Off
Note 3
Neutral Note 2
H B
K K Neutral
Note 1
Note 2
Note 3
120V
Phase J F
L L
Hot G Customer G
Transformer Primaries
D D
J F
E E 120V
Phase
L J F F
Hot
Note 1 Customer
G
G
Transformer Primaries
D D
E E
Phase 120V
L J F F
Note 4
G Customer
Transformer Primaries
186
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
M Series
Case Styles - Non-filtered Models
6VM1 6VM2 & 6VM4
100V
USE ONLY WITH USE ONLY WITH 120V
250V FUSES C 250V FUSES 230V C
DISCONNECT POWER
240V
DISCONNECT POWER
BEFORE REPLACING FUSES BEFORE REPLACING FUSES
D E D E
B B
A A
6VM1C 6VM4C
E D
D E
B
B
A
A
6VM1SC 6VM4SC
100V
USE ONLY WITH USE ONLY WITH 120V
250V FUSES 250V FUSES 230V
C 240V C
DISCONNECT POWER DISCONNECT POWER
BEFORE REPLACING FUSES BEFORE REPLACING FUSES
D E B E
A A
187
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
M Series
Case Styles - Filtered Models
3EXM1S & 3EZM1S 3EXM4S & 3EZM4S
G Threaded G Threaded
Insert Insert
1.13* 1.17*
28.7 29.7
D D
E E
B B
*±.020 [.508] A *±.020 [.508]
A
1.13*
28.7 D E
1.88* 3.09
Max. B
47.8 78.49
A
100V
USE ONLY WITH 120V
250V FUSES 230V
DISCONNECT POWER
240V C
BEFORE REPLACING FUSES
D
E
B
A *±.020 [.508]
188
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
M Series
Case Styles - Filtered Models (continued)
5EFM1C 5EHM4 & 5EFM4
100V
USE ONLY WITH
USE ONLY WITH
250V FUSES 250V FUSES
120V
230V
C
C 240V
DISCONNECT POWER DISCONNECT POWER
BEFORE REPLACING FUSES BEFORE REPLACING FUSES
E
D E D
A B
A
5EFM4C
3
D E
D E
B A
A
D D E
E
A B
A
189
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
M Series
Case Styles - Filtered Models (continued) Case Dimensions
5EFM4SC A B C D E F G
Part No.
USE ONLY WITH 100V
120V
250V FUSES 230V
C
240V
6VM1
DISCONNECT POWER
BEFORE REPLACING FUSES
190
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
M Series
Performance Data
Typical Insertion Loss
Measured in closed 50 Ohm system
3
Common Mode / Asymmetrical (L-G)
Differential Mode / Symmetrical (L-L)
Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line)
191
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
P Series
UL Recognized
CSA Certified
VDE Approved
PE filtered
PS non-filtered PS filtered
P Series
The P series CHAMELEON power entry module offers L models feature a high performance medical filter
the most popular features in a small footprint design designed to help bring most digital equipment
(including switching power supplies) into compliance
As the first 10A module to provide all five power with EN55022, Level B (as well as FCC part 15J, Class
entry functions in one compact design, the B) conducted emissions limits. They are available
chameleon module readily adapts to its environment with current ratings of 6 and 10A. These high
and the needs of international markets. performance versions are only available with
• Snap-in or flange mounting mounting ears, single voltage selection, in a complete
• Standard IEC 60321-1 C14 power inlet RFI shield with options for switch, fuses and current
ratings. Mounting extenders are not compatible with
• Both North American and metric fusing
the L or Z models.
capabilities
Z models provide a high performance three element
• Two voltage selection options (for 4-voltage
differential mode circuit filter, with extended EMI
selection, see the M, L or LA Series)
attenuation similar to the M Series Z models, to help
• Optional DPST on/off switch bring most digital equipment (including switching
• Filter options for general purpose, medical and power supplies) into compliance with EN55022, Level
high-performance EMI filtering B (as well as FCC Part 15J, Class B) conducted emis-
The CHAMELEON module’s compact design and sions limits. They are available with current ratings of
modular construction allows selection of the required 6 and 10A. These high performance versions are only
power entry feature — without altering the panel available with mounting ears, single voltage selection,
cutout. And the CHAMELEON module, with its in a complete RFI shield with options for switch, fuses
optional adapters, will fit several common panel and current ratings. Mounting extenders are not
cutouts. compatible with the L or Z models. For minimum
depth behind the panel, see the M Series
B models are non-filtered and incorporate an inter-
Filter Types connection block. The block connects the voltage
selection terminals of an unfiltered CHAMELEON
The CHAMELEON module has four filter and one module with an IEC connector and an optional switch
non-filtered option: to reduce external wiring. Compatible with the A or B
S models provide an extended performance two RFI shield options.
element circuit EMI filter, with attenuation similar to
the EEB Series power inlet filter. It offers protection
for general purpose applications with stray Line to
Ground and Line to Line noise that must be attenu-
ated at the power inlet. These filters have limited
leakage current and are available in current ratings of
3, 6 and 10A.
H models provide susceptibility protection with
minimal leakage current, and are suitable for patient
care and non-patient care medical equipment.
192
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
P Series
Ordering Information
Part numbers are constructed by selecting the alphanumeric character which represents the desired feature.
Note: For any option where shown as “0” use the digit ZERO (0) not the letter (O).
P S J 0 X S S 6 0
Mounting Style Switch Option Fuse Options Filter Current
E = Mounting ears 0 = Blank D = Dual fuse 0 = No filter
(Horizontal axis) S = Double pole S = Single fuse 3 = 3A
S = Snap-in single throw 6 = 6A
M = Mounting ears
(Vertical axis)
(DPST) X = 10A
3
Extender Input Voltage Select Filter Type Shield Options
193
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
P Series
Voltage Selection Shield Options
P series power entry modules include the voltage The P series offers several RF shield options. The
selector integral with the fuse holder. Three voltage metal shield, optional on S, H and B filtered models,
selection options are each supported by one of three provides shielding from radiated emissions and
different fuse holders. The fifth digit of the part provides an RF ground for the filter to the panel. This
number specifies which of the three fuse holders is shield is available in two versions; a shield of the filter
included to provide the desired voltage selection. components (designated by an A as the final digit)
The single voltage fuse holder (option “0”) has no and a complete shield (designated by B as the final
voltage indication markings. The dual voltage options digit).
select 115V or 230V by removing the fuse holder, flip-
ping it over, and reinstalling it. Voltage selection is The A shield covers the filter portion of the module
indicated through a window in the P Series door. The and increases performance of the filter by protecting
“SMPS” fuse holder (option “S”) jumpers two inde- the components from RFI coupling. This shield
pendent P Series terminals to indicate 230V allows the use of the C or J extender.
operation to a switching mode power supply. The The B shield covers the entire power entry module
“PRSR” parallel/serial fuse holder (option “X”) with metal, protecting the filter from RFI coupling,
connects the windings of the equipment’s dual and covering the mounting cut-out to block RFI
primary transformer (not included) to step down the entering or leaving the equipment. The B shield
voltage or double up the current. The markings on cannot be used with any extender.
the voltage selection fuse holders also remind the
A complete metal enclosure is integral to both the
user to install the appropriate fuse for the current at
high performance L and Z models, and must be spec-
the selected voltage.
ified by a C in the part number’s final digit. This
option is only available with the L or Z models.
Input Voltage Selection Schemes
S - “SPMS” Jumper Type
115V 230V
Power on/off
Hot G A Power
input
Note 1 Note 1 B
Ground Sel.
C
Note 1 Note 1 Jumpers
Neutral H D
SMPS
Provision for
single fusing
194
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
P Series
Fuseholder Accessories
Another feature of the P series power entry module is GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord
the versatile fusing arrangement. The fuse holder can
hold two 1/4” x 1-1/4” (3AG) or 5 x 20mm (metric)
fuses. Single fusing is supported with a conversion
clip that shorts one of the two fuse positions, and is
designated by an S in the sixth part number digit. A
module designated for a single fuse may be reconfig-
ured by the manufacturer or the user to accept two
fuses by simply removing the shorting clip. For appli-
cations intended for dual fusing, specify a D in the PA100: Power interconnect assembly
sixth part number digit. For voltage select models. Designed for use with
either filtered or non-filtered units, 6” wire leads
Conversion Clip for
Single Fuse
Applications
Interconnection Block
PA400: J Extender
Installation of the unfiltered versions of the P series
requires wiring of the IEC socket terminals to the Extends P Series height to fit J panel cutout
optional switch and the switch to the fuse holder. PA410: L Extender
Labor can be eliminated by ordering the module Extends P Series width to fit L panel cutout
with an interconnection block. This feature, desig-
nated by “BX” in the seventh and eighth digits, pre PA420: C Extender
wires the module so that only connection to the Extends P Series height to fit C panel cutout
equipment must be done during installation. The
interconnection block includes a plastic case to
prevent access to the internal connections.
The dimensions of this alternative are the same as the PA400
filtered versions. Extender for
J Series Extender
J-Series or others
Fuse holder
Optional switch
195
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Optional filter
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
P Series
Specifications Electrical Schematics
Maximum leakage current each Line to Ground: H Model
H & L Models S & Z Models LINE LOAD
@ 120 VAC 60 Hz: 2 A .25 mA
@ 250 VAC 50 Hz: 5 A .50 mA
Hipot rating (one minute):
Line to Ground: 2250 VDC
Line to Line: 1450 VDC
Rated Voltage(max.): 250VAC S Model
Operating Voltages: LINE LOAD
Selectable or Fixed 115/230 VAC
Operating Frequency: 50/60 Hz
Rated Current: Non-Filtered – 10A
Filtered – 3, 6 or 10A
L Model
Fuseholder: Accepts one or two fuses LINE LOAD
.25 x 1.25”(not included)
or 5 x 20mm (not included)
Switch: DPST
10,000 operations at 51A max. inrush
Z Model
LINE LOAD
Case Styles
Front View
PM PE PS
High Performance
Version Only
1.58 1.22
40.13 30.98
1.22 1.95
30.98 49.53
196
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
P Series
Case Styles (continued)
Extender Options
C Extender - FN260 J Extender - J Series
2.51 2.72
63.75 69.08
2.29
58.16
3
2.17 2.39
55.12 60.71
1.12
3.93 1.23 28.45
99.82 31.24
4.42
112.27
197
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
P Series
Case Styles (continued)
Shield Options “A” Shield “B” Shield
2.19 2.19
55.63 55.63
Note: Shields can only be used with filtered models. B shield may not be used with J or C extender
2.496
“B”
63.40
.06 1.575
R
1.524 40.00
.135
Mounting Hole Diameter 3.43
Note: For snap-in applications, the “A” sides must have a .020 [.508] radius on the installation side.
Dimensions are for front mount applications. Rear mount dimensions should be determined based on customer’s application
parameters. Snap-in models allow for front mounting only. Not recommended for use in plastic panels.
198
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
P Series
Performance Data
Common Mode / Asymmetrical (L-G)
Typical Insertion Loss Differential Mode / Symmetrical (L-L)
Measured in closed 50 Ohm system
S Models
3A 6A 10A
db db db
100 100 100
90 90 90
80 80 80
70 70 70
60 60 60
50 50 50
40 40 40
30 30 30
20 20 20
10 10 10
0 0 0
0.1 1 10 30 0.1 1 10 30 0.1 1 10 30
Frequency in MHz Frequency in MHz Frequency in MHz
H Models
3A
db
6A
db
10A
db
3
100 100 100
90 90 90
L Models
6A 10A
db db
100 100
90 90
80 80
70 70
60 60
50 50
40 40
30 30
20 20
10 10
0 0
0.01 0.1 1 10 30 0.01 0.1 1 10 30
Frequency in MHz Frequency in MHz
Z Models
6A 10A
db db
100 100
90 90
80 80
70 70
60 60
50 50
40 40
30 30
20 20
10 10
0 0
0.01 0.1 1 10 30 0.01 0.1 1 10 30
Frequency in MHz Frequency in MHz
199
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
P Series
Minimum Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line)
200
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
SR Series
20ESRMC2
UL Recognized
CSA Certified 20ESRM-3
VDE Approved*
6ESRMC2
6ESRM-3
SR Series Specifications
• Full Line of popular AC receptacles Rated Voltage (max.): 250 VAC
• Male and female power line connectors Materials:
• Snap-in and flange mount versions Insulator: Thermoplastic UL 94V-0 flame rating
• IEC60320-1 C-13 & C14 inlets rated up to 15A
• IEC60320-1 C-19 & C-20 inlets rated up to 20A
Prongs:
Terminals:
Solid brass, nickel plated
Brass, tin plated
3
Temperature Rating: For “cold” connections, 65°C
Ordering Information
.360
SR Series A B .719
D 1.575 9.14
18.26 40.00 .360
9.14
Leakage current designation .064
Dia.
E – Low Leakage (<0.5 mA) 1.63
.136
Current Rating Indicator C .125
3.17
.094*
2.39
3.45
Dia.
Pin Layout
6 = 15A max.* E
.134
Dia.
20 = 20A max.* 3.40
201
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
SR Series
Case Styles (continued)
6ESRMC2 20ESRMC2
1.079
A Cutout .956
27.4
C Cutout 24.30
.1259 .197
3.2 R .779 .1259 .177
5.0 R
C 19.8 A 3.2 4.5 1.27
E 32.30
B
6ESRFC3 20ESRM-3
.134 .137
Dia. Dia.
3.4 3.4
1.272
A Cutout
32.26
1.27
A B 32.30 Cutout
.102 .157
2.6 R .975
C 4.0 24.77
E .177
.205 R
4.5
C 5.2 .956
E 24.30
6ESRM-3
.134 .134
Dia. Dia.
3.4 3.4
A B D G Cutout
Case Dimensions
R A B C D E
Part No.
C E H
202
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
SRB Series
SRBP
UL Recognized
CSA Certified
VDE Approved*
SRBS8
SRB1 SRB2
SRB Series
Available Part Numbers Case Styles
Flange Mount SRB1
15SRB1 15SRB2 15SRBP 15SRB8
15SRB1-Q 15SRB2-Q 15SRBP-Q 15SRB8-Q C
15SRB1-R 15SRB2-R 15SRBP-R 15SRB8-R
15SRB1-S 15SRB2-S 15SRBP-S 15SRB8-S D A B
15SRB1-T 15SRB2-T 15SRBP-T 15SRB8-T E
D A B
E
SRBS1
Accessories
C
GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord
D
E A B
204
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
SRB Series
Case Styles (continued)
SRB8 SRBY8
.045 A
Blue
Blue
Green/Yellow
D E Grn/Yel
B DE B
Brown
Brown
0.96
max.
24.39
C
3
SRBS8 Case Dimensions
A B C D E
205
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
SRB Series
Recommended Panel Cutouts PC Board Layout
0.075
SRB1, SRB2, SRBP & SRB8 1.91 ∅
Front Mount Back Mount
.820 .900
0.520
20.8 22.9 13.21
.140 .140
1.200 3.56
∅ 1.200 ∅
3.56
30.48 30.48
1.575
.12
1.575 0.551
40.01 R. 40.01 .234 R.
3.05 5.94 Typ. 13.99
Typ. .685*
Tolerances ± .005 [0.13] unless otherwise noted
17.40*
*±.015 [0.38]
SRBS
0.188
G R Max.
4.775
SRBX
Cover
.722 .836
18.34 21.23
min. min.
Jacket
Flange
SRBY
Cover
1.05 1.15
26.67 29.21
min. min.
Jacket
Flange
206
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
SRB Series
Performance Data
Typical Insertion Loss
Measured in closed 50 Ohm system
Q R S T
db db db db
40 40 40 40
35 35 35 35
30 30 30 30
25 25 25 25
20 20 20 20
15 15 15 15
10 10 10 10
5 5 5 5
0 0 0 0
1 10 100 300 1 10 100 300 1 10 100 300 1 10 100 300
Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz
W
db
40
35
X
db
40
35
Y
db
40
35
Z
db
40
35
3
30 30 30 30
25 25 25 25
15 15 15 15
10 10 10 10
5 5 5 5
0 0 0 0
1 10 100 300 1 10 100 300 1 10 100 300 1 10 100 300
Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz
207
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
Engineering Notes
208
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .210
Selector Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .211
DA Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .212
DB Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .214
DC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .217
P Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .223
DC Filters
209
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
Introduction
STAY CONNECTED WITH CORCOM PRODUCTS TE has provided solutions in both power line filtering
and signal line filtering applications for many leading
TE Connectivity (TE) is a world leader in EMI-RFI fil-
communications companies. As data transmission
tering technology. Since 1955, TE has been providing
speeds increase and EMI-RFI issues multiply, TE has
EMI-RFI solutions to leading computer, industrial and
developed products to better solve the newer chal-
telecommunications companies worldwide. Whether
lenges communications companies encounter.
you are meeting FCC and international EMC stan-
dards on EMI-RFI emissions or developing a newly Corcom DC power line and signal line filters
designed piece of equipment from being disturbed have been included in:
by EMI-RFI in the environment, a power line filter will
• Network routing equipment
help your equipment with compliance.
• Servers
This section highlights TE’s product offering of DC
rated products. Whether the issues involve filtering • Modems
noise on the data lines or on the power lines, TE can • Switching equipment
provide the needed solutions for both susceptibility • Wireless cabinets
and to help achieve system emissions and immunity
• Ethernet hubs
compliance.
• Base stations
As new technologies in the Telecom-Datacom indus-
try are developed and introduced, TE continues to • Repeater stations
design and develop new products to address the • Power supplies for all types of communications
EMI-RFI filtering issues. TE’s design engineers are equipment
very actively working with telecom and datacom sys-
tem engineers to solve EMI-RFI issues.
TE has developed DC filter products
In working with two of the leading North American specifically for the communications industry
communications equipment companies, TE engineers
including:
solved the EMI-RFI issues present by applying 48
VDC filters at the primary input of the DC power sup- • DC power line clean-up filters
ply. One of the applications was on network routing • Medium and multiple-stage high-performance DC
equipment and required a two-stage 48VDC filter on power line filters
the input to the DC power supply. TE applied high-
• High frequency DC power line filters (up to 3GHz)
frequency attenuating 48VDC filters on the load side
of the DC power supplies to solve high-frequency • High current DC power line filters (up to 60A)
EMI-RFI issues. • Data-transmission signal line filters
Control Modules
Protection
Modules
Alarm Module
48VDC Line Filters
210
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
Selector Chart
Compact
DC Inlet
Connector
Yes No
Fuse
Required
Yes No
DB
NEW
Series
60A
Page 214
Current
Series Input Output Mounting Options
Rating
P
2-pin Inlet 1/4” Terminal
Snap In Panel
or Fuse 3, 6, 10A
4
Flange Panel
DC Filters
DA / DAS
1/4” Terminal Snap In Panel
3, 6, 10,
3-pin Inlet or or —
15A
PC Board Flange Panel
DB Compact,
Standard,
Feedthrough
2-pin Flange Panel & Hi-Performance
High Current Wire Leads and Filters 60A
Inlet Rear Mount and
Unfiltered Inlet &
Plug available
Separately
DC
Circuit Breaker
Redundant Stud Bulkhead
Redundant Stud and/or 15, 30, 60,
or or
Terminal Block High Frequency 100, 125A
Terminal Block Flange Chassis
Performance
211
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
DA Series
EN
60 950
UL Recognized
CSA Certified
TUV Certified
DA Series Specifications
• General purpose line filters for DC applications up Hipot rating (one minute):
to 125VDC. Line to Ground: 2250 VDC
LIne to Line: 1450 VDC
• Compact with a 3-pin inlet connector
• Available in 3, 6, 10 and 15A versions Rated Voltage (max): 125 VDC
• Flange mount with 1/4” or PCB terminals Rated Current: 3 to 15A
• Mates with a standard MOLEX* connector Operating Ambient Temperature Range
(HCS Series) (at rated current Ir): -10°C to +55°C
In an ambient temperature (Ta) higher than +55°C
the maximum operating current (Io) is calculated as
Ordering Information follows: Io = Ir (85-Ta)/45
3 DA F 1
Electrical Schematic
Output Styles LINE LOAD
1 – .250 [6.3] spade terminals
P – PC board mount pins
Case Style
F – Flange mount
S – Snap-in Accessories
DA Series Red
Green/Yellow
Black
Current Rating
3, 6, 10 or 15A
212
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
DA Series
Case Styles Case Dimensions
A B C D E
DAF1 Part No.
DAF1
C
A B
D DAS1
E
DAFP
Recommended Panel Cutouts
DAS1
A
DAF
0.23 max.
.820 .900
20.8 22.9
D C
.140 Dia. (2) .140 Dia. (2)
1.200 3.56 1.200 3.56
30.48 30.48
E 1.575
.12
1.575
.234
40.01 R 40.01 R
3.05 5.94
Rear View
B
DAS
"A"
4
0.815
20.70
DC Filters
R 0.188
4.78
(4x)
DAFP
.551
Performance Data
.380 Max.
213
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
DB Series
EN
60 950
UL Recognized 60DB8
CSA Certified
TUV Certified
60DBJ8
DB Series Specifications
• Compact connector for high-current DC Hipot rating (one minute):
applications Filtered Models DBR & DBP
• Reliable performance in a compact assembly Line to Ground: 2121 VDC n/a
LIne to Line: 1768 VDC 1600 VAC
• Polarized mating scheme
Rated Voltage (max): 150VDC* 300 VDC
• Easy customer termination of power source
• Plug and receptacle available pre-terminated Rated Current: 60A (all versions)
in standard wire lengths Operating Ambient Temperature Range
• Available filtered or unfiltered (at rated current Ir): -10°C to +55°C
In an ambient temperature (Ta) higher than +55°C
the maximum operating current (Io) is calculated as
Ordering Information follows: Io = Ir (85-Ta)/30
60 DB F 8
Output Styles
Filtered Models
8 – 6” Wire leads Available Part Numbers
Connector Only
L1 – 1’ Cable pair
L3 – 3’ Cable pair Filtered Models
L9 – 9’ Cable pair 60DB8 60DBJ8
Omit for none 60DBF8 60DBX8
Type
Connectors Only
R – Receptacle with clips
P – Plug with clips 60DBR 60DBP
J – Compact filter 60DBRL1 60DBPL1
F – Feedthrough capacitors 60DBRL3 60DBPL3
X – High performance 60DBPL9
Blank – Standard filter
DB Series WARNING
This is not approved for hot swap or current
Current Rating interruption in DC applications. Doing so will
60A result in irreparable damage to contacts.
214
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
DB Series
Electrical Schematics Case Styles
Load
Line
Red (RTN)
Label
Black (-VDC)
DBF8
-VDC
DB8 & DBF8
(Black)
C A 6.0 Min.
Load
Line
E
0.375
0.277
(ref)
RTN 0.297
(Red)
B D F
0.423
Label
Red (RTN)
Black (-VDC) 4
Wire #6 AWG, 300V
DBX8 #4-40 Thread
Extra Flexible
DC Filters
#6-32 Thread IAW UL10198
(4x) (2x) (2 x)
-VDC
(Black)
Load
Line
RTN
(Red)
DBX8
C A 6.0 Min.
E
0.375
0.277
(ref)
0.423
B D F Label
Black (-VDC)
60DBPL 60DBRL
215
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
DB Series
Case Styles (continued) Case Dimensions
DBPL A B C D E F
C A Part No.
D E
60DBJ8
B
60DB8
F 60DBF8
Black (-VDC)
60DBX
Wire #6 AWG, 300V
Extra Flexible
D E
B
F
Performance Data
0.150 Dia.
Black (-VDC) Wire #6 AWG, 300V
2x
Extra Flexible Minimum Insertion Loss
IAW UL10198
(2 x) Measured in closed 50 Ohm system
Red (RTN)
R 0.062 1.370 R 0.125 1.3
34.79 33.02
(4x) 1.57 (4x) 3.175
1.055
26.79
0.985
25.01
0.528 0.493
13.41 12.52
Front Mount Panel Cutout Rear Mount Panel Cutout
Tolerance ± .005 Tolerance ± .005
Differential Mode / Symmetrical (Line to Line)
Accessories / Tooling
Insertion/Extraction Tool: 1643922-1*
Crimp per TE spec: 114-13206
Crimp tool: M22520/23-01
Indenter head: M22520/23-04
Locator: M22520/23-11
Connector system locking kit¹:
Contact TE
216
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
DC Series
EN
60 950
UL Recognized
CSA Certified
TUV Certified
60DCF6B 15DCF10
DC Series Specifications
• General purpose line filters for DC applications up Hipot rating (one minute):
to 125VDC Line to Ground: 2250 VDC
• Available with or without a circuit breaker LIne to Line: 1450 VDC
• Available with feedthrough capacitors for added Rated Voltage (max): 80 VDC
high frequency performance Rated Current: 15 to 125A
• Available in both flange mound (DCF) and Operating Ambient Temperature Range
bulkhead mount (DCB) configuration (at rated current Ir): -10°C to +55°C
In an ambient temperature (Ta) higher than +55°C
the maximum operating current (Io) is calculated as
follows: Io = Ir (85-Ta)/30
Ordering Information
4
60 DC B 6 B
Electrical Schematics
DC Filters
Options
B – Circuit breaker
Standard Performance
F – Feedthrough capacitors
BF – Circuit breaker and Note 2
Note 3
feedthrough LINE LOAD
217
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
DC Series
Available Part Numbers
Standard Performance High Performance
15DCF6 15DCF10 15DCB10F 15DCB6F
30DCF6 30DCF10 30DCB10F 30DCB6F
60DCF6 60DCF10 60DCB10F 60DCB6F
100DCF6 100DCF10 100DCB10F 100DCB6F
125DCF6 125DCF10 125DCB10F 125DCB6F
15DCF6B 15DCF10B 15DCB6BF
30DCF6B 30DCF10B 30DCB6BF
60DCF6B 60DCF10B 60DCB6BF
100DCF6B 100DCF10B 100DCB6BF
125DCF6B 125DCF10B 125DCB6BF
15DCB6 15DCB10 15DCB10BF
30DCB6 30DCB10 30DCB10BF
60DCB6 60DCB10 60DCB10BF
100DCB6 100DCB10 100DCB10BF
125DCB6 125DCB10 125DCB10BF
15DCB6B 15DCB10B
30DCB6B 30DCB10B
60DCB6B 60DCB10B
100DCB6B 100DCB10B
125DCB6B 125DCB10B
Termination Options
Style 6 (15, 30 & 60A) Style 6 (100 & 125A)
• Supplied with #10-32 redundant studs • Supplied with 1/4-20 redundant studs
• 0.625 [15.88] spacing like polarity • 0.750 [19.05] spacing like polarity
• 0.750 [19.05] spacing opposing polarity • 1.00 [25.4] spacing opposing polarity
• Torque specification: 27 ±3 in-lb. • Torque specification: 45 ±2 in-lb
218
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
DC Series
Recommended Panel Cutouts Cutout Dimensions
D
Part No.
15DCB6B(F)
15DCF6B
A
B
C
D
E
F
4
C Holes: .157 [3.99] Dia. (4) 15DCB10B(F)
DC Filters
See case dimensions for 15DCF10B
spacing.
30DCB6B(F)
B F
30DCF6B
30DCB10B(F)
30DCF10B
Tolerance: ±.005/.13
A E 60DCB10B(F)
60DCF10B
60DCF6B(F)
60DCF6B
DCB6B(F) & DCB10B(F) 100 to 125A DCB6B(F) & DCB10B(F) 100 to 125A
Part No. A B C
100DCB6B(F)
Holes: .157 [3.99] Dia. (4) 100DCF6B
C 125DCB6B(F)
See case dimensions for
spacing.
125DCF6B
1.250
B 100DCB10B(F)
31.75 .625
15.88
100DCF10B
Tolerance: ±.005/.13
.262 1.557 125DCB10B(F)
6.65 39.55
A
1.500 x 0.781
38.10 x 19.84
125DCF10B
219
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
DC Series
Case Styles
DCB6 & DCB6B DCB10 & DCB10B (60 to 125A)
C A C A
F E E
RTN
VDC
RTN
-VDC
L L L L
I O I O
B D N A D B N A
E D VDC
RTN E D
OFF
OFF
ON
VDC
RTN
ON
-VDC
RTN
RTN RTN
L L L L
B I O B I O
D N A D N A
E D E D
-VDC
-VDC
RTN
-VDC -VDC
RTN
F F
RTN
-VDC
L L RTN L L RTN
D I O I O
B N A B D N A
E D -VDC
RTN E D -VDC
OFF
ON
-VDC
RTN RTN
-VDC -VDC
L L L L
I O I O
D B N A B D N A
E D E D
OFF
OFF
RTN RTN
ON
ON
-VDC -VDC
DC Series
Case Styles (continued) Case Dimensions (continued)
DCF10B (60 TO 125A)
C A A B C D E F
E
Part No.
L L
I O
D
B N
E
A
D
OFF
60DCB6B(F)
ON
VDC
RTN
60DCF6
Tapped insert: 6-32 (4) F
60DCF6B
Case Dimensions
60DCF10
A B C D E F
60DCF10B
Part No.
15DCB6(F) 100DCB6(F)
15DCB6B(F) 100DCB6B(F)
15DCB10(F)
100DCB10(F)
4
15DCB10B(F) 100DCB10B(F)
DC Filters
15DCF6 100DCF6
15DCF6B(F) 100DCF6B
15DCF10 100DCF10
15DCF10B(F) 100DCF10B
30DCB6(F) 125DCB6(F)
30DCB6B(F) 125DCB6B(F)
30DCB10(F) 125DCB10(F)
30DCB10B(F) 125DCB10B(F)
30DCF6 125DCF6
30DCF6B 125DCF6B
30DCF10 125DCF10
30DCF10B 125DCF10B
221
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
DC Series
Performance Data (continued)
Minimum Insertion Loss
Measured in closed 50 Ohm system
Standard Performance
Common Mode / Asymmetrical (Line to Ground)
222
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
P Series
EN
60 950
UL Recognized
CSA Certified
TUV Certified
P Series Specifications
• Full flexibility of design in the most compact Hipot rating (one minute):
package Line to Ground: 2250 VDC
• General purpose designed for DC applications LIne to Line: 1450 VDC
• Mates with a standard MOLEX* connector (HCS Rated Voltage (max): 80 VDC
Series) which prevents accidental connection to Rated Current: 3 to 10A
AC Power
Fuseholder*: .25 x 1.25” or
5 x 20 mm
Terminals: .187 x .032 [4.8 x .81] terminal tabs
Ordering Information
P S 0 0 0 D D3D
Operating Ambient Temperature Range
(at rated current Ir): -10°C to +40°C
In an ambient temperature (Ta) higher than +40°C
the maximum operating current (Io) is calculated as
4
Shield Options
follows: Io = Ir (85-Ta)/45
D = Complete Shield
DC Filters
(DC Version)
Current Rating
3 = 3A
6 = 6A
Electrical Schematic
X = 10A
Filter Type LINE LOAD
D = DC version
Fuse Options
D = Dual fuse
S = Single fuse
Available Part Numbers
Input Voltage Select
0 = Single voltage PE000DD3D PS000DD3D
PE000DD6D PS000DD6D
Switch Options PE000DDXD PS000DDXD
0 = No switch
PE000SD3D PS000SD3D
Extender Options PE000SD6D PS000SD6D
0 = None PE000SDXD PS000SDXD
Mounting Style
E = Mounting ears
S = Snap-in
223
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
P Series
Case Styles Case Dimensions
PE A B C D E F
Part No.
A .07
1.78 min. Radius
Ground connection
PS E
External Edge
(1) .020 R Min.
.508
C
D
Note: The external edges (installation side) on the "D" sides of the
cutout should have a minimum .020" radius. For optimal retention
against extraction, the corresponding inner edge should be sharp,
without paint or coatings. Edge coatings, including anodization are
B also discouraged for good shield contact.
A
Performance Data
Accessories Minimum Insertion Loss
Red Measured in closed 50 Ohm system
Black Common Mode / Asymmetrical (Line to Ground)
GA210 – (shown above) Pre-assembled connector
housing with two 36” long 18 gauge wires to mate
with P Series DC filters
Differential Mode / Symmetrical (Line to Line)
MOLEX Part Numbers:
03-12-1026 DC Connector housing for P Series
18-12-1222 Female terminals (2 per connector)
224
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
Type of
Filter Capacitor
Feedthrough
Application Application
AC DC AC DC
5
225
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
226
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
IMPEDANCE (Ω)
components above a few MHz 40
frequency 80
227
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
FFA Series
Component Recognized by
UL to US and Canadian Requirements
FFA Series
Case Style Case Dimensions
Resin Fill T2 (Mounting thread)
T1 (Terminal thread) A B C D E F
Part No.
10FFA6-BA
B C D E F
16FFA6-CA
A 32FFA6-CA
63FFA6-GB
T1 – Terminal Thread
100FFA6-HC
Torque
Part No. Thread
max. in.lb.
200FFA6-HD
10FFA6-BA/CE/CJ M3 4
16FFA6-CA/DG/HN M4 11
300FFA6-HF
32FFA6-CA/DH/HN
63FFA6-GB/JK/NP M6 22
10FFA6-CE
100FFA6-HC/NP/PP M8 44
200FFA6-HD/NP/PP M10 70 16FFA6-DG
250FFA6-HF/NP/PP M12 97 32FFA6-DH
300FFA6-HF/NP/PP M16 177
63FFA6-JK
T2 – Mounting Thread
100FFA6-NP
Part No.
10FFA6-BA/CE/CJ
Thread
Torque
max. in.lb.
200FFA6-NP
5
16FFA6-CA M12 x 1 35 250FFA6-NP
32FFA6-CA
229
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
FFA Series
Available Part Numbers
Performance Data
230
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
FFD Series
Component Recognized by
UL to US and Canadian Requirements
231
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
FFD Series
Case Style Case Dimensions
Resin Fill T2 (Mounting thread)
T1 (Terminal thread) A B C D E F
Part No.
10FFD6-CA
B C D E F
16FFD6-CA
A 32FFD6-CA
63FFD6-HB
T1 – Terminal Thread
100FFD6-NC
Torque
Part No. Thread
max. in.lb.
200FFD6-ND
10FFD6-CA/HE M3 4
16FFD6-CA/HE M4 11
10FFD6-HE
32FFD6-CA/HE
63FFD6-HB/NH M6 22 16FFD6-HE
100FFD6-NC/PK M8 44 32FFD6-HE
200FFD6-ND/RP M10 70
63FFD6-NH
100FFD6-PK
T2 – Mounting Thread
200FFD6-RP
Torque
Part No. Thread
max. in.lb.
10FFD6-CA/HE
16FFD6-CA/HE M12 x 1 35
32FFD6-CA/HE
63FFD6-HB/NH M20 x 1 89
232
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
FFD Series
Available Part Numbers
Performance Data
233
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
AFC Series
Component Recognized by
UL to US and Canadian Requirements
234
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
AFC Series
Case Style Case Dimensions
Resin Fill
T1 (Terminal thread)
T2 (Mounting thread) A B C D E F
Part No.
10AFC6-A
10AFC6-B
B C D E F 16AFC6-B
16AFC6-C
A
16AFC6-G
T1 – Terminal Thread
16AFC6-H
Torque
Part No. Thread
max. in.lb.
20AFC6-B
10AFC6-A/B M3 4
16AFC6-B/C/G/H 32AFC6-B
20AFC6-B M4 11 32AFC6-C
32AFC6-B/C/F/G/H 32AFC6-F
63AFC6-C/G/H M6 22 32AFC6-G
100AFC6-G/H/K/N M8 44
32AFC6-H
200AFC6-H/K/N/P M10 71
M12 97 63AFC6-C
250AFC6-H/K/N/P
63AFC6-G
300AFC6-H/K/N/P M16 177
63AFC6-H
T2 – Mounting Thread
100AFC6-G
100AFC6-H
5
Part No. Thread
Torque
100AFC6-K
max. in.lb.
235
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
AFC Series
Available Part Numbers
10AFC6-A 32AFC6-H 200AFC6-P
10AFC6-B 63AFC6-C 250AFC6-H
16AFC6-B 63AFC6-G 250AFC6-K
16AFC6-C 63AFC6-H 250AFC6-N
16AFC6-G 100AFC6-H 250AFC6-P
16AFC6-H 100AFC6-H 300AFC6-H
20AFC6-B 100AFC6-K 300AFC6-K
32AFC6-B 100AFC6-N 300AFC6-N
32AFC6-C 200AFC6-H 300AFC6-P
32AFC6-F 200AFC6-K
32AFC6-G 200AFC6-N
Performance Data
236
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
DFC Series
Component Recognized by
UL to US and Canadian Requirements
237
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
DFC Series
Case Style Case Dimensions
Resin Fill T2 (Mounting thread)
T1 (Terminal thread) A B C D E F
Part No.
10DFC6-C
B C D E F
16DFC6-C
A
16DFC6-G
16DFC6-H
T1 – Terminal Thread
Torque 16DFC6-N
Part No. Thread
max. in.lb.
10DFC6-C M3 4 32DFC6-C
16DFC6-C/G/H/N M4 11 32DFC6-G
32DFC6-C/G/H/N
M6 22
32DFC6-H
63DFC6-C/G/H/N
100FDC6-G/H/N/P M8 44 32DFC6-N
200DFC6-H/N/P/R M10 71
63DFC6-C
250DFC6-P/Q/T M12 97
63DFC6-G
M16 177
300DFC6-P/Q/T 63DFC6-H
T2 – Mounting Thread 63DFC6-N
100DFC6-G
Torque
Part No. Thread 100DFC6-H
max. in.lb.
100DFC6-N
M10 x 1 27
10DFC6-C 100DFC6-P
16DFC6-C/G/H M12 x 1 35 200DFC6-H
32DFC6-C/G/H 200DFC6-N
63DFC6-C/G/H M16 x 1 62
200DFC6-P
16DFC6-N
32DFC6-N 200DFC6-R
M20 x 1 89
63DFC6-N
100DFC6-G/H/N 250DFC6-P
100DFC6-P 300DFC6-P
M24 x 1 124
200DFC6-H/N/P 250DFC6-Q
300DFC6-Q
200FFC6-R M27 x 1.5 142
250DFC6-T
300DFC6-T
238
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
DFC Series
Available Part Numbers
Performance Data
5
239
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
Engineering Notes
240
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .242
SignalSentry Filtered Modular Jacks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .243
SignalSentry Product Part Number Matrix / Ordering Information . . . .244
SignalSentry Product Selector Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .245
L Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .247
L – Ganged Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .248
LC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .249
LCT Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .250
N Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .251
X Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .252
Z Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .253
Model Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .255
L, LC, LCT and X Series RJ Jack Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .255
N and Z Series RJ Jack Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .257
6
Signal Line Products
241
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
Introduction
Corcom brand SignalSentry filtered modular Corcom brand SignalSentry filtered modular
jack series product combines different levels of jack series product has expanded into 80
filtering with RJ45 and RJ11 modular jacks to different products for filtering the signal line,
solve signal line noise problems and crosstalk. including inductor and capacitor, shielded,
ganged, low profile and surface mountable
versions. Designs not only save valuable panel
space, but also place the filtering elements
where they can be most effective in eliminating
RFI.
The L and N series RJ11 and RJ45 jacks offer
filtering with inductance and optional shielding,
while the LC and LCT series combine induc-
tance with 82pF or 820pF capacitors. The X and
Z series complete the offering with unfiltered
versions of our standard profile and low profile
jacks.
Use the selector chart to combine your filtering
performance with the RJ11 or RJ45 jacks.
Mechanical dimensions are listed following the
series information.
For the latest information and additional tech-
nical articles, find Corcom products on the
Internet at www.corcom.com.
242
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
243
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
RJ11 Model Contact Loading Program RJ45 Model Contact Loading Program
1 2 3 4 5 6 1 2 3 4 5 6 7 8
244
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
Yes Filtered No
Try The
X
Series
Standard Profile
Modular Jack
Level Page 252
of Filtering
Z
Series
Inductor Inductor Low Profile
and Capacitor Only Modular Jack
Page 253
Ganged
Jacks
Try The
LC Yes No
Series
820pF
Modular Jack
Page 249 Try The Try The
LCT
Series
82pF
L (Ganged)
Series
Standard Profile
L
Series
Standard Profile
6
Modular Jack Modular Jack Modular Jack
Page 250 Page 248 Page 247 Signal Line Products
N
Series
Low Profile
Modular Jack
Page 251
245
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
Engineering Notes
246
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
L Series
UL Recognized
CSA Certified
RJ11 RJ11 with RJ45 with RJ45
Block Filter Sleeve Filter
L Series Specifications
• Inductive filtering in standard RJ11, RJ45, or Contacts:
handset jacks. Material: Phosphor Bronze
Plating: 50 microinches gold
• Available with standard ferrite sleeve Barrier underplating: 100 microinches nickel
inductors or higher performance ferrite Resistance:
Initial: 20 m max.
blocks
After 500 mating cycles: 30 m max.
• Available unshielded or shielded with board Ferrites:
grounded shield or spring fingered panel Type: High resistivity, nickel zinc ceramic
ground interface Sleeves: Single-aperture cylinders
Block: Multi-aperture rectangular prism
Available Part Numbers Shield Material: Tin-plated copper alloy
Inductor Filter Housing Material: Glass-filled polyester (UL94V-0)
RJH-4L-B RJ45-6L-S Dielectric Withstanding Voltage:
RJ11-2L-S RJ45-6L-B Line to Line and Line to Ground: 1000 VAC for
RJ11-2L-B RJ45-8L-S 60 seconds
RJ11-4L-S RJ45-8L-B Printed Circuit Board Retention:
RJ11-4L-B Before soldering: 1 lb. minimum
After soldering: 20 lb. minimum
RJ11-6L-S
RJ11-6L-B
Inductor Filter and Shield Typical Impedance in Ohms
RJ11-2L2-B
RJ11-4L1-S
RJ11-4L1-B
RJ45-6L1-S
RJ45-6L1-B
RJ45-6L2-S
150
140
130
120
110
6
RJ11-4L2-S RJ45-6L2-B 100
90
Impedance in Ohms
RJ11-4L2-B RJ45-8L1-S
Signal Line Products
80
70
RJ11-6L1-S RJ45-8L1-B 60
RJ11-6L1-B RJ45-8L2-S 50
40
RJ11-6L2-S RJ45-8L2-B 30
20
RJ11-6L2-B 10
0
1 25 100 200 500
Frequency in MHz
Ferrite block
Ferrite sleeve
Shield 2 Shield 1
Model dimensions and PC board layout on pages 255-259
247
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
L – Ganged Series
4RJ11
UL Recognized 6RJ11
CSA Certified
.470
A .050
1.27
Housing Material: Glass-filled polyester (UL94V-0)
11.94
Dielectric Withstanding Voltage:
Line to Line and Line to Ground: 1000 VAC for
60 seconds
Printed Circuit Board Retention:
B Before soldering: 1 lb. minimum
C
After soldering: 20 lb. minimum
.325 .100 + .008
.050 [1.27] .030 - .003 Dia.
8.25 2.54
.590
14.99.040
1.02
Typical Impedance in Ohms
150
.195
140
.410 .165 130
10.41 4.19 120
110
Ports A B C D 100
80
2
70
60
248
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
LC Series
UL Recognized
CSA Certified
LC Series Specifications
• Chip capacitors provide enhanced filtering Contacts:
performance on each line Material: Phosphor Bronze
Plating: 50 microinches gold
• Available with block or sleeve inductance Barrier underplating: 100 microinches nickel
Resistance:
• Available with board grounded shield or Initial: 20 m max.
spring fingered panel ground interface After 500 mating cycles: 30 m max.
Capacitors:
Type: Monolithic ceramic chip
Standard Value: 820 pF
Standard Tolerance: ± 20%
Performance Data
Ferrites:
Type: High resistivity, nickel zinc ceramic
Sleeves: Single-aperture cylinders
Typical Insertion Loss Block: Multi-aperture rectangular prism
Shield Material: Tin-plated copper alloy
Housing Material: Glass-filled polyester (UL94V-0)
Dielectric Withstanding Voltage:
Line to Line and Line to Ground: 1000 VAC for
60 seconds
Printed Circuit Board Retention:
Before soldering: 1 lb. minimum
6
After soldering: 20 lb. minimum
Available Part Numbers
RJ11-2LC1-S RJ11-6LC2-S
Signal Line Products
RJ11-2LC1-B RJ11-6LC2-B
RJ11-2LC2-S RJ45-6LC1-S
RJ11-2LC2-B RJ45-6LC1-B
RJ11-4LC1-S RJ45-6LC2-S
Model dimensions and PC board layout on pages 255-259 RJ11-4LC1-B RJ45-6LC2-B
RJ11-4LC2-S RJ45-8LC1-S
RJ11-4LC2-B RJ45-8LC1-B
RJ11-6LC1-S RJ45-8LC2-S
RJ11-6LC1-B RJ45-8LC2-B
249
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
LCT Series
UL Recognized
CSA Certified
250
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
N Series
UL Recognized
CSA Certified Shield 3
RJ11
Shield 4
RJ45
N Series Specifications
• Low profile SignalSentry filtered jack Contacts:
Material: Phosphor Bronze
• Available with sleeve or block inductors Plating: 50 microinches gold
Barrier underplating: 100 microinches nickel
• Available unshielded or shielded with board Resistance:
grounded shield or spring fingered panel Initial: 20 m max.
ground interface After 500 mating cycles: 30 m max.
Ferrites:
Type: High resistivity, nickel zinc ceramic
Sleeves: Single-aperture cylinders
Typical Impedance in Ohms Block: Multi-aperture rectangular prism
Shield Material: Tin-plated copper alloy
100
90 Housing Material: Black glass-filled polyamide
Impedance in Ohms
80 (STANYL TE250F3)
70
60
Dielectric Withstanding Voltage:
50 Line to Line and Line to Ground: 1000 VAC for
40 60 seconds
30
20 Printed Circuit Board Retention:
10 Before soldering: 1 lb. minimum
0 After soldering: 20 lb. minimum
1 25 100 200 500 1000
Frequency in MHz
6
Ferrite block Ferrite sleeve
Unshielded
Ferrite Block Model dimensions and PC board layout on pages 255-259
251
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
X Series
UL Recognized
CSA Certified
RJ45 RJ11
X Series Specifications
• Unfiltered standard jack Contacts:
Material: Phosphor Bronze
• RJ11 or RJ45 Plating: 50 microinches gold
Barrier underplating: 100 microinches nickel
• 2, 4, 6 or 8 loaded contacts Resistance:
Initial: 20 m max.
• Available unshielded or shielded with board
After 500 mating cycles: 30 m max.
grounded shield or spring fingered panel
ground interface Shield Material: Tin-plated copper alloy
Housing Material: Glass-filled polyester (UL94V-0)
Dielectric Withstanding Voltage:
Line to Line and Line to Ground: 1000 VAC for
60 seconds
Printed Circuit Board Retention:
Before soldering: 1 lb. minimum
After soldering: 20 lb. minimum
Shield 1 Shield 2
Available Part Numbers
RJ11-2X RJ45-6X
RJ11-4X RJ45-8X
RJ11-6X RJ45-8X1
RJ45-8X2
252
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
Z Series
UL Recognized
CSA Certified
Shield 3 Shield 4
RJ11 RJ45
Z Series Specifications
• Low profile Contacts:
Material: Phosphor Bronze
• Unfiltered Plating: 50 microinches gold
Barrier underplating: 100 microinches nickel
• Available unshielded or shielded with board Resistance:
grounded shield or spring fingered panel Initial: 20 m max.
ground interface After 500 mating cycles: 30 m max.
Shield Material: Tin-plated copper alloy
Housing Material: Black glass-filled polyester
(VALOX 457)
Dielectric Withstanding Voltage:
Available Part Numbers Line to Line and Line to Ground: 1000 VAC for
60 seconds
RJ11-6Z RJ45-8Z
Printed Circuit Board Retention:
RJ11-6Z3 RJ45-8Z3 Before soldering: 1 lb. minimum
RJ11-6Z4 RJ45-8Z4 After soldering: 20 lb. minimum
253
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
Engineering Notes
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
Model Dimensions
.780
.590 19.81
14.99
.040 .04
1.02 1.02
.322 .395
8.19 10.03
.322 .485
8.18 12.32
6
5 .520 6
4 5
3 13.21 .540
4
2 3 13.72
1 2
1
6
.165 .165 1
.195
4.95 4.19 4.19 2
.400 3
10.16 4
5
6
.322 .485
8.18 12.32
.050
.075 1.27 Signal Line Products
.075 1.91 (5 places)
6
5 1.91
4 .540
3 13.72
2
1 .128 ± .003
.210 Dia.
.345 3.25 ± .08
5.33 8.76 (2 holes)
Part No. For all RJ11 L, LC, LCT and X Series Models
RJ11-2LC1-S RJ11-2LC1-B RJ11-4L1-S RJ11-6L1-B Shown from Component Side
RJ11-4LC1-S RJ11-4LC1-B RJ11-6L1-S RJ11-6LCT1-S
RJ11-6LC1-S RJ11-6LC1-B RJ11-4L1-B RJ11-6LCT1-B
255 255
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
.540 .780
13.72 19.81
.04
1.02 .04
1.02
.195 .165
4.19 .195 .165 .165
4.95 4.19 4.19
4.95
.322 .395
8.18 10.03
.322 .485
8.18 12.32
8
7 8
6 7
5 6
5 .620
4 15.75
3 4
3
2 2
1 1
8
.050 .090
7 .210 .345 1.27 2.29
6 5.33 8.76 .128±.003 Dia.
5 .620
4 15.75 3.25±.08
3 (4 PLACES)
2
1
Part No.
For all RJ45 L, LC, LCT and X Series Models
RJ45-6LC1-S RJ45-8LC1-S RJ45-6LC1-B
RJ45-6L1-S RJ45-8L1-S RJ45-6L1-B Shown from Component Side
RJ45-8LCT1-S RJ45-8LCT1-B RJ45-8LC1-B
RJ45-8L1-B
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
Edge of board
.195 1
4.95 .300 2
7.62 3
4
.322 .395
8.18 10.03 .050
.075 1.27
1.91 (3 Spaces)
4
3
2 .128±.003 Dia.
1 3.25±.08
(2 holes)
.250
6.35 .350
8.89
Part No.
RJH-4-L-B
.515*
.485 13.08
12.32 .010
.010 .25
.25
.120 .135
3.05 3.43 .165
6
4.19
.165 .135
4.19 3.43 *to top of shield
.217 .430
.217 .400 5.51 10.92
5.51 10.16
Signal Line Products
6
5
6 4 .550
5 3 13.97
4 .520 2
3 13.21 1
2
1
257 257
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
.515* .485
13.08 12.32 .010
.254
.217 .430
5.51 10.92 .217 .40
5.51 10.16
6
5
4 .550
3 13.97
2
1
RJ11 Low Profile, PC Board Layout RJ45 – Low Profile, Style 3 Shield
.99 Max. .740
25.15 18.80
.076±.003 .515*
.217 .350 13.08
1.93±.08 5.51 8.89
Dia. .250
(2 PLACES) 6.35
.030 + .008/- .003 Dia.
.76 +.20/-.08 .120 .135 .165
(6 PLACES) 3.05 3.43 .4.19
1 .050 (5 SPACES)
2
.400 1.27 *to top of shield
3
10.16 4
5 .217 .430
6 5.51 10.92
.075
.080 1.91 8
2.03 .120 .128±.003 Dia. 7
3.05 3.25±.08 6
5 .630
(2 HOLES) 16.00
4
3
2
1
RJ45 Low Profile, Style 4 Shield RJ45 Low Profile PC Board Layout
.700 .740
17.78 18.80
.217 .350
.515*
13.08 .010 5.51 8.89
.25 .076±.003 Dia. .250
1.93±.08 6.35
(2 Places) .030 +.008/-.003 Dia.
.76 +.20/-.08
.120 .135 1
3.05 .165 (8 Places)
3.43 4.19 2
3 .050 (7 Spaces)
.450 4 1.27
*to top of shield 11.43 5
6
7
.217 .430
5.51 10.92 8
.095
2.41
.050
8 1.27
7 .120
6 .128±.003 Dia.
5 .630 3.05 3.25±.08
4 16.00 (2 Places)
3
2
1
6
Signal Line Products
259
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
Engineering Notes
260
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .262
Understanding RFI Power Line Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . .263
Understanding Hipot Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .266
Understanding Leakage Current (Touch Current) . . . . . . . . . . . . . . . . . . .267
Understanding Insertion Loss . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .268
Appendix A - Conducted RFI Emissions Testing . . . . . . . . . . . . . . . . . . . .269
Appendix B - Conducted RFI Susceptibility Testing . . . . . . . . . . . . . . . . .270
Appendix C - Health Care Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . .270
Appendix D - Safety Agency File Numbers . . . . . . . . . . . . . . . . . . . . . . . . .271
Technical Notes
261
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
Introduction
262
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
What Is Radio Frequency Interference (RFI)? test data must be submitted to the FCC for type
approval. Class A and all other Class B equipment
RFI is unwanted electromagnetic energy in the
must be verified—i.e. the manufacturer conducts his
frequency range generally used for radio communica-
own emissions testing and verifies that he complies
tions. The frequency ranges of interest are 10kHz to
with the limits, but no forms need to be filed with the
30MHz for conducted phenomena and 30MHz to
FCC.
1GHz for radiated phenomena.
Further details on FCC requirements can be obtained
What are the modes of propagation of RFI? from the FCC, RF Devices Branch (Authorization and
RFI is propagated via radiation (electromagnetic Standards Division), Washington, DC 20554, (301)
waves in free space) and by conduction over signal 725-1585.
lines and AC power systems.
What are CE markings and RFI filters?
Radiated - One of the most significant contributors
As of January 1, 1996, electrical and electronic equip-
to radiated RFI from electronic equipment is the AC
ment shipped to Europe is required to be labeled
power cord. The power cord is often an efficient
with the CE marking. In order to apply the CE
antenna since its length approaches a quarter wave
marking, equipment must meet the General Product
length for the RFI frequencies present in digital
Safety Directive and Electromagnetic Compatibility
equipment and switching power supplies.
Directive.
Conducted - RFI is conducted over the AC power
RFI power line filters are components and therefore
system in two modes. Common mode (asymmetrical)
not covered by the CE requirements, but they are
RFI is present on both the line and neutral current
used in electronic systems to meet EMC specifica-
paths with reference to the ground or earth path.
tions.
Differential mode (symmetrical) RFI is present as a
voltage between the line and neutral leads. Two of the most common emission specifications are
EN 55011 for industrial, science, and medical equip-
Why Be Concerned with RFI? ment, and EN 55022 for information technology
The designers and manufacturers of digital equip- equipment. The conducted emission limits for these
ment must concern themselves with RFI for two specifications are the same and broken down to Class
reasons. (1) Their equipment must operate properly in “A” and Class “B” limits. Electronic equipment that
the application environment, often in the presence of may be connected to a power main shared with a
significant levels of RFI. (2) Their equipment must not residential area must comply with the more stringent
emit RFI that interferes with RF communications Class “B” limits. The measurement technique is done
often vital to health and safety. The necessity for reli- using quasi-peak and average detection, with
able RF communications has given rise to legal different limits for each measure in dB above one
regulations ensuring RFI control for electronic equip- microvolt.
ment.
Technical Notes
There are several immunity tests to which electronic
What are the FCC requirements? equipment must comply, one of which is the electri-
cally fast transient (EFT), IEC 61000-4-4. The
The U.S. Federal Communications Commission (FCC)
equipment must continue to operate during this test.
has established regulations to reduce the interference
The transient wave form is a 5ns rise time with a 50ns
potential of electronic computing devices (FCC
duration. A burst is induced onto the power line at
Rules, Part 15, Subpart J). A computing device is
1kV with a repetition rate of 5kHz lasting 15ms and
defined as any electronic device or system that
repeated every 300ms. The test simulates switching
generates and uses timing signals or pulses at a rate
of inductive loads and contacts.
in excess of 10,000 per second and that uses digital
techniques. It is important to note that a switching To pass the EFT test, it is important that the RFI
power supply does not itself fall into this category, filter’s enclosure have a good RF ground with the
but that its emissions must still meet the limits when
it is installed in a piece of equipment that is subject
to the regulations.
system’s chassis ground. This provides a lower
impedance path from the safety ground to the
system ground. The shielding effect of the RFI filter’s
metal enclosure eliminates radiation into the system’s
7
The level of emissions the equipment must meet
cabinet induced by the conducted EFT burst. Stray
depends on whether it is marketed for use in a resi-
capacitance may occur from any of the three input
dential environment (Class B) or in a commercial,
power wires to chassis ground where voltage can
industrial, or business environment (Class A). The
build up from the EFT burst and cause system inter-
limits for Class B are more stringent than those for
rupts. The RFI filter’s inductor offers an impedance to
Class A (see Appendix A). Most Class B equipment
the burst.
must undergo certification, meaning that emissions
263
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
In cases where the stray capacitances have caused It is important to note that Insertion Loss does not
multiple RF ground planes or where plastic enclo- describe the RFI attenuation provided by a filter in
sures are used, an inductive choke may be needed to the power line environment. In the power line envi-
provide isolation of the safety ground from the ronment the relative magnitudes of the source and
chassis ground. load impedances must be estimated and the appro-
priate filter configuration selected such that the
What Is a Power Line Interference Filter?
greatest possible impedance mismatch occurs at
A power line interference filter is a primary tool avail- each termination.
able to the designer of electronic equipment to
This dependence of filter performance on terminated
control conducted RFI both into the equipment
impedances is the basis for the concept of
(potential equipment malfunction) and out of the
“mismatching networks.”
equipment (potential interference to other system
elements or RF communication). By controlling the What is the concept of power line filters as
RFI conducted onto the power cord, a power line “Impedance Mismatching Networks”?
filter also contributes significantly to the amount of
RFI power line filters can be thought of as “imped-
radiated RFI.
ance mismatching networks” at higher frequencies in
A power line filter is a multiple-port network of the attenuation band. Network analysis shows that
passive components arranged as a dual low-pass the greater the mismatch of filter impedance to
filter; one network for common mode attenuation, terminating impedance, the more effective the filter
another network for differential mode attenuation. is in attenuating RF energies.
The network provides attenuation of RF energy in the
Common mode power line impedance is considered
stopband of the filter (typically above 10kHz), while
to be low (on the order of 50 Ohms). Thus, following
passing the power current (50-60Hz) with little or no
the concept of an impedance mismatch, Corcom
attenuation.
power line filters employ a high common mode
How Does a Power Line Interference Filter impedance (series inductance) on the power line side
Work? of the filter.
Power line interference filters, as passive, bilateral For load (equipment) side common mode impedance
networks, have complex transfer characteristics, mismatch, Corcom products are available with a high
which are extremely dependent upon source and impedance (series inductance) or a low impedance
load impedance. The magnitude of this transfer char- (shunt capacitance).
acteristic describes the attenuation performance of High (common mode) impedance filters for use with
the filter. In the power line environment, however, the low impedance equipment include the EP, H, 6A Q, R
source and load impedances are not defined. There- and V series. Low (common mode) impedance filters
fore the industry has standardized upon the practices for use with high impedance equipment include the
of verifying filter uniformity through measurement of B, EC, ED, EF, G, K, N, 3A Q, S, SK, T, W, X, Y, and Z
attenuation with 50 Ohm resistive source and load series.
terminations. This measurement is defined to the
Insertion Loss (I.L.) of the filter. Knowing the input impedance of your equipment,
then, may be useful in initially selecting the filter
P (Ref) series most likely to solve your RFI problems.
I.L. = 10 log L
PL However, since this impedance is almost certainly
complex (having both resistive and reactive compo-
where PL (Ref) is the power transferred from the
nents), it may vary widely over the RFI frequency
source to the load without the filter, and PL is the
range. Hence a variety of series should be evaluated
power transferred when a filter is inserted between
in your quest for the most effective filter in any one
the source and load. The Insertion Loss may also be
application.
expressed in terms of voltage or current ratios as
shown: Do all filter networks with the same circuit and
V (Ref) element values perform identically?
I.L. = 20 log L
VL All filter networks with the same circuit and element
values do not perform identically. Element values are
I (Ref) specified and measured at a single frequency (usually
I.L. = 20 log L 1kHz). Filter performance is required over the entire
IL frequency spectrum, not just at the frequency of
component measurement. The type of component
where VL (Ref) and IL are measured without a filter construction and method of incorporation into a filter
and VL and IL are measured with a filter. are extremely important to filter performance.
264
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
Figure 1 illustrates the high-frequency performance How do you perform susceptibility testing?
difference between the three leaded capacitor
Susceptibility testing involves injection of noise onto
construction employed by TE and a conventional
the power input lines while monitoring the equipment
method of construction. Both units would be speci-
for proper operation. Quantification of the noise
fied by the same nominal 1kHz component value,
levels to be found in the equipment environment is
approximately 5000pF.
difficult at best. Through analysis of solutions to
Figure 1: Insertion Loss specific susceptibility problems, TE has developed
recommended noise injection levels, which proved a
db V Conventional high level of confidence for reliable equipment opera-
0 Construction tion in the real world environment. The test methods
10 and injection noise levels are found in Appendix B.
20
Is installation important to filter performance?
30
40 TE Connectivity Mounting and wiring of the filter are critical influ-
Construction ences on its performances. A power line filter is best
50
installed at the power line input point of your equip-
60 ment. The filter is a barrier to high frequency signals.
70 Its purpose must not be defeated by stray capaci-
80 tance coupling the power input leads to the power
90 output leads, or to any other conductors in the
100 protected equipment.
20.0 40.0 60.0
Normally the case of the filter is bolted to the frame-
Frequency MHz work or chassis of the electronic equipment it
protects. The line side leads should be kept short and
How Do You Select a Power Line Interference well separated from the load side leads. The ideal
Filter? isolation system is a bulkhead-mounted filter incor-
The only way to select and qualify a power line inter- porating a line cord connector, such as the Corcom
ference filter is to test the unit in your equipment. As EC, ED, or EF power line filter series.
mentioned above, the performance is highly How Do You Know Which Filter To Test?
dependent on equipment load impedance. Filter
A filter, or ordered group of filters, likely to solve your
performance cannot be derived from single imped-
interference control problem can be obtained by
ance (50 Ohm) insertion loss data. Performance is a
using the selector chart at the front of each section.
complex function of filter element impedances and
Every Corcom filter series is available in a range of
equipment impedances which vary in magnitude and
current ratings and packages. Detailed specifications,
Technical Notes
phase over the frequency spectrum of interest. Filter
including prices, are listed on the individual series’
selection testing should be performed in your equip-
catalog sheets referenced in the selector chart. Tele-
ment to your required level of performance for both
phone numbers of distributors who stock all TE
conducted emission control (FCC, VDE) and suscep-
products are listed on the back cover of this catalog.
tibility control.
Why Be Concerned with Safety Agency
How do you perform conducted emission tests?
Requirements?
Conducted emission testing requires a quiet RF envi-
All components in the AC power system, including
ronment—usually a shielded enclosure—a line
power line filters, must be safe from potential fire and
impedance stabilization network, and an RF voltage
shock hazard. The standards set by the various safety
instrument such as a tuned receiver or a spectrum
agencies, like UL, CSA, VDE, and SEV, provide guide-
analyzer. Additional testing information is given in
Appendix A. The RF ambient of the test environment
should be at least 20 dB below the desired compli-
ance limit for accurate results. The line impedance
lines to assist the designer in specifying safe and
reliable components. Components which carry the
compliance symbols from these agencies have been
designed and manufactured to comply with these
7
stabilization network (LISN) is required to establish a
standards. A summary of safety agency requirements
desired source impedance for the power line input.
can be found in Appendix C.
This is an important part of the test procedure, since
this impedance directly affects the measured emis-
sion levels. The correct bandwidth for the
measurement receiver is also a critical test parameter.
265
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
What are the significant requirements of UL cations” with the package style and dimensional data
and CSA? from your specific filter will adequately define your
selection.
UL and CSA are primarily concerned with high poten-
tial withstand capability, temperature rise, creepage Are there other parameters that need to be
distances, and material temperature capability at the specified?
time of manufacture. There are three additional requirements that are
What are the additional aspects of VDE safety often specified. Below are our recommended values:
requirements? 1. Insulation Resistance: 6000 M @ 100VDC
In addition to the requirements of UL and CSA, VDE 2. Current Overload: 6 X rated current for 8 seconds
specifies limits of hipot, insulation resistance, and
3. Humidity: 21 days at 40°C 95% RH
change of component values, at the conclusion of
extreme environmental conditioning. The condi- What are the test methods for verification of
tioning includes life tests at elevated temperatures, the important specification parameters?
long term humidity, and temperature/humidity
Some filter specifications may be unfamiliar to you or
cycling. Components that bear the VDE symbol of
may require slightly different measuring techniques
safety have been designed and tested not only for
than you have been using for other components. It is
initial safety but also for safety over the life of the
very important that supplier and customer use the
product.
same techniques for verification of electrical specifi-
How Do You Specify a Power Line Filter? cations, in order to assure an uninterrupted flow of
The filter you have selected through system testing quality components. Three specifications that must
can best be specified by the data parameters found be clearly understood are hipot testing, leakage
on the appropriate catalog page. Combining the current, and insertion loss.
product family parameters listed under the “specifi-
Leakage current (also referred to as “touch current”) Figure 2: Leakage Current Measurement
is an important specification of power line filters.
There has always been an undeserved negative Filter
connotation to this term. Leakage current is not a Variac Isolation Under Test
Transformer
function of the quality of components, but is a direct
function of the line-to-ground capacitance value. The 60HzAC No Connection
larger the capacitance, the lower the impedance to Input To Load
Voltage Terminals
common mode currents, and the greater the
common mode interference rejection. Hence, leakage
current is a measure of filter performance—the 120V, 60Hz
higher, the better. or 1500
250V, 60Hz
H N
Why, then, do safety agencies specify a maximum
0.15
allowable leakage current? This is done in order to
limit the magnitude of expected ground return
currents. The line-to ground capacitors provide a
path for 50/60Hz current to flow to the chassis. As
long as the equipment is grounded, these currents
Note that filter case must be floating, not grounded.
will flow in the ground circuit and present no hazard.
However, in the unlikely but always possible circum-
stance where the ground circuit is faulty, the earth The circuit of Figure 2 illustrates the measurement
connection may be established by the body of a technique for leakage current. The leakage limits
person. If this should occur, the maximum leakage apply to each side of the line independently. The test
current specification limits the ground return current circuit provides the correct value by shunting the
to a safe value, typically 0.5 to 5.0mA. The limits set line-to-ground path that is not being measured by
by safety agencies are based on end user equipment the millimeter impedance. This test is realistic,
specifications, such as those given below. because power to a system is provided by a hot line
and a neutral line, with the neutral basically at ground
potential, thus providing no addition to the leakage.
Note that the leakage current is directly proportional
Capacitive Current Limits to line voltage and frequency. Hence, it is unwise to
Limits for Class I specify an operation frequency greater than 60Hz
Country Specification Grounded Equipment (e.g., 400Hz) when leakage current limits must also
U.S.A. UL 60950 3.5 mA, 120V, 60Hz be met.
Technical Notes
Europe EN 60950 3.5 mA, 250V, 50Hz
267
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
How is it measured? 50
268
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
What can it be used for? published data when tested in the standardized
manner.
Standardized insertion loss data will not accurately
predict a filter’s performance in your equipment. Accordingly, “typical” insertion loss data is not mean-
However, it does serve as an important tool for veri- ingful. The data to which you test should be minimum
fying product consistency through incoming values. Most of the insertion loss data published by
inspection. TE are guaranteed minimums, and as such can be
tested for a positive indication of component consis-
The criterion for acceptance would be that the meas-
tency.
ured insertion loss must either meet or exceed the
Figure A1
250 H 50 H
Technical Notes
1.2 8 .25
To
Power 1000 50
10 5
Source
10 5 1000
1.2 8 .25
250 H 50 H
50 Equipment
Line Impedence Spectrum
Stabalization Network Analyzer
269
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
Figure A3
270
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
VDE Approval
VDE Approval
File 706400-4730
All except IK series File 706400-4730
Technical Notes
All filtered modules except J Series
File 706400-1550
TUV Approval
All non-filtered modules except J Series
File E2173035
DAF, DAS Series
File E2173028.01
DCB, DCF Series
Accessories
File T72091763.01
Filtered DB Series UL Recognition
File T72081913.01 Guide ECBT2, File E106884
Non-filtered DB Series (Connectors)
MA100
271
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
Engineering Notes
272
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
273
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
274
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
275
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
276
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
277
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
278
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
279
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
280
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
281
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
282
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
283
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
284
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
Engineering Notes
285
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
ALABAMA IDAHO
CARTWRIGHT & BEAN, INC. HUNTSVILLE, AL 800-242-5876 HALBAR-RTS, INC. KIRKLAND, WA 425-893-8400
ALASKA INDIANA
TE CONNECTIVITY MUNDELEIN, IL 847-573-6504 RATHSBURG ASSOCIATES CARMEL, IN 317-818-7055
ARIZONA IOWA
LUSCOMBE ENGINEERING PHOENIX, AZ 602-678-1955 RATHSBURG ASSOCIATES BLOOMINGTON, MN 952-893-1400
ARKANSAS KANSAS
ELECTRA REPS PLANO, TX 972-599-2130 RATHSBURG ASSOCIATES OLATHE, KS 913-829-2800
CALIFORNIA KENTUCKY
LUSCOMBE ENGINEERING (SOUTH) CAMARILLO, CA 805-987-4880 RATHSBURG ASSOCIATES EASTERN 248-615-4000
LUSCOMBE ENGINEERING (SOUTH) COSTA MESA, CA 714-546-4880 RATHSBURG ASSOCIATES WESTERN 317-818-7055
LUSCOMBE ENGINEERING (SOUTH) SAN DIEGO, CA 858-385-2655
STRAUBE ASSOCIATES (NORTH) MOUNTAIN VIEW, CA 650-969-6060 LOUISIANA
ELECTRA REPS PLANO, TX 972-599-2130
CANADA
WEISS COMPANY MONTREAL 514-337-6769 MAINE
WEISS COMPANY OTTAWA 613-599-8787 CONTI-YOUNGER ASSOCIATES MARLBORO, MA 508-485-7204
WEISS COMPANY TORONTO 905-238-9548
WEISS COMPANY VANCOUVER 604-276-8735 MARYLAND
ASTROREP MID-ATLANTIC, INC. DOYLESTOWN, PA 267-880-6321
COLORADO
STRAUBE ASSOCIATES ROCKY MASSACHUSETTS
MOUNTAINS, INC. WESTMINSTER, CO 303-426-0890 CONTI-YOUNGER ASSOCIATES MARLBORO, MA 508-485-7204
CONNECTICUT MEXICO
CONTI-YOUNGER ASSOCIATES MARLBORO, MA 508-485-7204 TE CONNECTIVITY MUNDELEIN, IL 847-573-6504
DELAWARE MICHIGAN
ASTROREP MID-ATLANTIC, INC. DOYLESTOWN, PA 267-880-6321 RATHSBURG ASSOCIATES NOVI, MI 248-615-4000
DISTRICT OF COLUMBIA MINNESOTA
ASTROREP MID-ATLANTIC, INC. DOYLESTOWN, PA 267-880-6321 RATHSBURG ASSOCIATES BLOOMINGTON, MN 952-893-1400
FLORIDA MISSISSIPPI
CBX ELECTRONICS CASSELBERRY, FL 407-774-9100 CARTWRIGHT & BEAN, INC. HUNTSVILLE, AL 800-242-5876
GEORGIA MISSOURI
CARTWRIGHT & BEAN, INC. NORCROSS, GA 800-242-5876 RATHSBURG ASSOCIATES ST. LOUIS, MO 636-946-1001
ILLINOIS MONTANA
RATHSBURG ASSOCIATES (NORTH) ITASCA, IL 630-625-5100 HALBAR-RTS, INC. KIRKLAND, WA 425-893-8400
RATHSBURG ASSOCIATES (SOUTH) ST. LOUIS, MO 636-946-1001
286
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
OREGON WYOMING
HALBAR-RTS, INC. BEAVERTON, OR 503-624-5741
STRAUBE ASSOCIATES ROCKY
PENNSYLVANIA MOUNTAINS, INC. WESTMINSTER, CO 303-426-0890
ASTROREP MID-ATLANTIC, INC. (EAST) DOYLESTOWN, PA 267-880-6321
RATHSBURG ASSOCIATES (WEST) PITTSBURGH, PA 248-615-4000
PUERTO RICO
CBX ELECTRONICS ALTAMONTE SPRINGS, FL 407-774-9100
RHODE ISLAND
CONTI-YOUNGER ASSOCIATES MARLBORO, MA 508-485-7204
287
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
288
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
Global Contacts
Americas
Argentina – Buenos Aires Canada – Toronto Mexico – Mexico City United States
Phone: +54-11-4733-2200 Phone: +905-475-6222 Phone: +52-55-1106-0800 Harrisburg, PA
Fax: +54-11-4733-2211 Fax: +905-474-5520 +01-800-733-8926 Phone: +1-717-564-0100
Product Information Center: Fax: +52-55-1106-0901 Fax: +1-717-986-7575
Brasil – São Paulo
Phone: +905-470-4425 Product Information Center:
Phone: +55-11-2103-6000 For Latin/South American
Fax: +905-474-5525 Phone: +1-800-522-6752
Fax: +55-11-2103-6030 Countries not shown Fax: +1-717-986-7575
Colombia – Bogota Phone: +54-11-4733-2015
Chile – Santiago Mundelein, IL
Phone: +57-1-319-8959 Fax: +54-11-4733-2083
Phone: +56-2-345-0361 Phone: +1-847-680-7400
Fax: +56-2-223-1477 Fax: +57-1-319-8960 Fax: +1-847-680-8169
Asia/Pacific
Australia – Sydney Japan – Kawasaki, Kanagawa New Zealand – Auckland Singapore – Singapore
Phone: +61-2-9554-2600 Phone: +81-44-844-8111 Phone: +64-9-634-4580 Phone: +65-6482-0311
Fax: +61-2-9502-2556 Fax: +81-44-812-3207 Fax: +64-9-634-4586 Fax: +65-6482-1012
Product Information Center: Product Information Center:
Philippines – Makati City Taiwan – Taipei
Phone: +61-2-9840-8200 Phone: +81-44-844-8013
Phone: +632-848-0171 Phone: +886-2-8768-2788
Fax: +61-2-9634-6188 Fax: +81-44-812-3200
Fax: +632-867-8661 Fax: +886-2-8768-2268
India – Bangalore Korea – Seoul
People’s Republic of China Thailand – Bangkok
Phone: +91-80-285-40800 Phone: +82-2-3415-4500
Hong Kong Phone: +66-2-955-0500
Fax: +91-80-285-40820 Fax: +82-2-3486-3810
Phone: +852-2735-1628 Fax: +66-2-955-0505
Indonesia – Jakarta Malaysia – Selangor Fax: +852-2735-0243
Vietnam – Ho Chi Minh City
Phone: +65-6482-0311 Phone: +60-3-7805-3055 Shanghai Phone: +84-8-930-5546
Fax: +65-6482-1012 Fax: +60-3-7805-3066 Phone: +86-21-2407-1588 Fax: +84-8-930-3443
Fax: +86-21-2407-1599
Europe/Middle East/Africa
Austria – Vienna France - Cergy-Pontoise Cedex Lithuania and Latvia Slovenia – Ljubljana
Phone: +43-1-905-60-0 Phone: +33-1-3420-8888 Lithuania – Vilnius Phone: +386-1561-3270
Fax: +43-1-905-60-1333 Fax: +33-1-3420-8600 Phone: +370-5-213-1402 Fax: +386-1561-3240
Product Information Center: Product Information Center: Fax: +370-5-213-1403
South Africa – Port Elizabeth
Phone: +43-1-905-60-1228 Phone: +33-1-3420-8686 Product Information Center:
Phone: +27-41-503-4500
Fax: +43-1-905-60-1333 Fax: +33-1-3420-8623 Phone: +370-5-211-3016
Fax: +27-41-581-0440
France Export Divisions – Fax: +370-5-213-1403
Belarus – Minsk
Cergy-Pontoise Cedex Spain – Barcelona
Phone: +375 17 237 47 94 Netherlands –
Phone: +33-1-3420-8804 Phone: +34-93-291-0330
Fax: +375 17 237 47 94 ’s-Hertogenbosch
Fax: +33-1-3420-8699 Fax: +34-93-201-7879
Phone: +31-73-6246-246
Belgium – Kessel-Lo
Germany – Bensheim Fax: +31-73-6212-365 Sweden – Upplands Väsby
Phone: +32-16-352-300
Phone: +49-6251-133-0 Product Information Center: Phone: +46-8-50-72-50-00
Fax: +32-16-352-355
Fax: +49-6251-133-1600 Phone: +31-73-6246-999 Fax: +46-8-50-72-50-01
Bulgaria – Sofia Product Information Center: Fax: +31-73-6246-998
Switzerland – Steinach
Phone: +359-2-971-2152 Phone: +49-6251-133-1999 Norway – Nesbru Phone: +41-71-447-0447
Fax: +359-2-971-2153 Fax: +49-6251-133-1988 Phone: +47-66-77-88-50 Fax: +41-71-447-0444
Czech Republic and Slovakia Greece – Athens Fax: +47-66-77-88-55
Turkey – Istanbul
Czech Republic – Kurim Phone: +30-210-9370- Poland – Warsaw Phone: +90-212-281-8181/2/3
Phone: +420-541-162-111 396/397 Phone: +48-22-4576-700 +90-212-282-
Fax: +420-541-162-223 Fax: +30-210-9370-655 Fax: +48-22-4576-720 5130/5430
Product Information Center:
Hungary – Budapest Product Information Center: Fax: +90-212-281-8184
Phone: +420-541-162-113
Phone: +36-1-289-1000 Phone: +48-22-4576-704
Fax: +420-541-162-104 Ukraine – Kiev
Fax: +36-1-289-1010 Fax: +48-22-4576-720
Phone: +380-44-206-2265
Denmark – Glostrup Product Information Center: Romania – Bucharest Fax: +380-44-206-2264
Phone: +45-43-48-04-00 Phone: +36-1-289-1016 Phone: +40-21-311-3479/3596 Product Information Center:
Fax: +45-43-44-14-14 Fax: +36-1-289-1017 Fax: +40-21-312-0574 Phone: +380-44-206-2265
Egypt – Cairo Ireland – Dublin Russia – Moscow Fax: +380-44-206-2264
Phone: +202-419-2334 Phone: +353-1-866-5612 Phone: +7-495-790-7902
United Kingdom –
Fax: +202-417-7647 Fax: +353-1-866-5714 Fax: +7-495-721-1893
Stanmore, Middlesex
Product Information Center:
Estonia – Tartu Israel – Petach-Tikva Phone: +44-8706-080208
Phone: +7-495-790-7902-404
Phone: +372-5138-274 Phone: +972-3-929-0999 Fax: +44-208-954-6234
Fax: +7-495-790-7902-401
Fax: +372-7400-779 Fax: +972-3-919-1088 Product Information Center:
Russia – St. Petersburg Freephone (UK only):
Finland – Helsinki Italy – Collegno (Torino) Phone: +7-812-718-8192 +0800-267-666
Phone: +358-95-12-34-20 Phone: +39-011-4012-111 Fax: +7-812-718-8193 Phone: +44-8706-080208
Fax: +358-95-12-34-250 Fax: +39-011-4031-116 Fax: +44-208-420-8095
Product Information Center:
Phone: +39-011-4012-632
Fax: +39-011-40-287-632
Dimensions are in inches and millimeters unless otherwise specified. Values in italics For email, phone or live chat, please go to
are metric equivalents. Dimensions are shown for reference purposes only. te.com/help
Specifications subject to change. corcom.com
FOR MORE INFORMATION
te.com/industry/commercial-building-technology
corcom.com
Part numbers in this brochure are RoHS Compliant*, unless marked otherwise.
*as defined www.te.com/leadfree
te.com
corcom.com
© 2011 Tyco Electronics Corporation, a TE Connectivity Ltd. company. All Rights Reserved.
1654001 CIS JG 06/2011
Corcom, TE Connectivity, TE connectivity (logo) and TE (logo) are trademarks. Other logos, product and/or
company names might be trademarks of their respective owners.