Vous êtes sur la page 1sur 32

3

Frame fixings / Stand-off installation


installation
Stand-off installation

3 Frame fixings / stand-off installation

▪▪ SXR▪frame▪fixing 3
▪▪ FUR▪universal▪frame▪fixing 9
▪▪ SXS▪frame▪fixing 14
fixings / Stand-off

▪▪ N▪hammerfix 17
▪▪ F-S▪window▪frame▪fixing 20
▪▪ F-M▪metal▪window▪frame▪fixing 22
▪▪ FFSZ▪/▪FFS▪window▪from▪screws 24
▪▪ Thermax▪8/10▪Stand-off▪installation▪ 26
Frame fixings

▪▪ VBS-M▪remedial▪wall▪tie 29
Frame

3
3

2
SXR Frame fixing
The all-round solution with European Technical Approval (ETA)
for solid and hollow building materials

Frame fixings / Stand-off installation


Façade sub-structures Façade sub-structures

VERSIONS APPROVALS
▪▪ Zinc-plated▪steel
▪▪ Stainless▪steel
BUILDING MATERIALS
Approved for:
▪▪ Concrete▪≥▪C12/15
▪▪ Vertically▪perforated▪brick
▪▪ Hollow▪ blocks▪ made▪ from▪ lightweight▪
concrete
▪▪ Perforated▪sand-lime▪brick
▪▪ Solid▪sand-lime▪brick
▪▪ Aerated▪concrete
▪▪ Solid▪ block▪ made▪ from▪ lightweight▪ and▪
normal▪weight▪concrete
3
▪▪ Solid▪brick
▪▪ Thermal▪insulation▪blocks
Also suitable for:
▪▪ Natural▪stone▪with▪dense▪structure
▪▪ Solid▪panel▪made▪from▪gypsum

ADVANTAGES APPLICATIONS FUNCTIONING


▪▪ The▪special▪design▪enables▪use▪in▪solid▪ ▪▪ Façade,▪ceiling▪and▪roof▪sub-structures▪ ▪▪ The▪SXR▪is▪for▪push-through▪installation.
and▪ hollow▪ building▪ materials▪ with▪ made▪of▪wood▪and▪metal ▪▪ The▪ SXR▪ expands▪ in▪ solid▪ building▪
an▪ anchorage▪ depth▪ of▪ just▪ 50  mm,▪ ▪▪ Windows materials▪ and▪ knots▪ in▪ hollow▪ building▪
ensuring▪an▪economical▪fixing. ▪▪ Doors▪and▪gates materials.
▪▪ The▪ETA▪approval▪covers▪use▪in▪a▪range▪ ▪▪ Wardrobes ▪▪ With▪ vertically▪ perforated▪ bricks▪ only▪
of▪ solid▪ and▪ hollow▪ building▪ materials,▪ ▪▪ Cable▪trays use▪rotary▪drilling▪(not▪impact▪drilling).
and▪guarantees▪a▪secure▪fixing. ▪▪ Squared▪timbers ▪▪ Countersunk▪ head▪ screws▪ are▪
▪▪ The▪ special▪ design▪ of▪ plug▪ and▪ screw▪ ▪▪ Kitchen▪cabinets recommended▪ for▪ the▪ installation▪ of▪
compliment▪ ▪ each▪ other▪ to▪ ensure▪ timber▪ constructions;▪ in▪ the▪ case▪ of▪
optimum▪ handling.▪ The▪ plug▪ has▪ a▪ metal▪ constructions,▪ use▪ plugs▪ with▪ a▪
positive▪hold▪for▪ease▪of▪installation.▪ wide▪sleeve▪rim▪and▪a▪moulded▪washer▪
▪▪ The▪ extensive▪ range▪ of▪ SXR▪ with▪▪ on▪ the▪ screw,▪ which▪ also▪ features▪ an▪
diameters▪of▪6,▪8▪and▪10 mm▪offers▪the▪ integrated▪hexagon▪socket.
right▪plug▪for▪every▪fixing.

INSTALLATION

3
SXR Frame fixing

TECHNICAL DATA
Frame fixings / Stand-off installation

SXR-T▪-▪with▪fischer▪safety▪screw

zinc-plated stainless hot-dip Drill hole Min. drill Min. Anchor Max. fixture Drive Sales
steel steel galvanised diameter hole depth embedment length thickness unit

Approval
Items to order only
steel for through depth
fixings
do h2 hnom (hv) l t fix
Art.-No. Art.-No. Art.-No. DIBt ETA [mm] [mm] [mm] [mm] [mm] [pcs]
Item gvz A4 fvz
SXR 8 x 60 T 502999 — — ▯ ■ 8 70 50 60 10 T30 50
SXR 8 x 80 T 503000 — — ▯ ■ 8 90 50 80 30 T30 50
SXR 8 x 100 T 503001 — — ▯ ■ 8 110 50 100 50 T30 50
SXR 8 x 120 T 503002 — — ▯ ■ 8 130 50 120 70 T30 50
SXR 10 x 80 T 046263 046272 — ▯ ■ 10 90 50 80 30 TX40 50
SXR 10 x 100 T 046264 046274 — ▯ ■ 10 110 50 100 50 TX40 50
SXR 10 x 100 T — — 509534 — — 10 110 50 100 50 TX40 50
SXR 10 x 120 T 046265 046278 — ▯ ■ 10 130 50 120 70 TX40 50
SXR 10 x 120 T — — 509535 — — 10 130 50 120 70 TX40 50
SXR 10 x 140 T 046266 046279 — ▯ ■ 10 150 50 140 90 TX40 50
SXR 10 x 140 T — — 509536 — — 10 150 50 140 90 TX40 50
SXR 10 x 160 T 046267 046283 — ▯ ■ 10 170 50 160 110 TX40 50
SXR 10 x 180 T 046268 046285 — ▯ ■ 10 190 50 180 130 TX40 50
SXR 10 x 200 T 046269 046286 — ▯ ■ 10 210 50 200 150 TX40 50

3 SXR 10 x 230 T
SXR 10 x 260 T
046270
046271
046287
046288 1)






10
10
240
270
50
50
230
260
180
210
TX40
TX40
50
50
1) delivery on request

TECHNICAL DATA

SXR▪-▪without▪screw

SXR-Z▪-▪with▪zinc-plated▪fischer▪safety▪screw▪
for▪Cross▪drive▪PZ-bit

Drill hole Min. drill-hole Min. embedment Anchor Max. fixture Drive Sales
Items to order only diameter depth for through depth length thickness unit
fixings
do h2 hnom (hv) l t fix
Item Art.-No. [mm] [mm] [mm] [mm] [mm] [pcs]
SXR 6 x 35 503228 6 45 30 35 5 — 100
SXR 6 x 50 503229 6 60 30 50 20 — 100
SXR 6 x 60 503230 6 70 30 60 30 — 100
SXR 8 x 60 506194 8 70 50 60 10 — 100
SXR 8 x 80 506196 8 90 50 80 30 — 100
SXR 8 x 100 506198 8 110 50 100 50 — 100
SXR 8 x 120 506199 8 130 50 120 70 — 100
SXR 6 x 35 Z 503231 1) 6 45 30 35 5 PZ2 50
SXR 6 x 50 Z 503232 1) 6 60 30 50 20 PZ2 50
SXR 6 x 60 Z 503233 1) 6 70 30 60 30 PZ2 50
1) not pre-assembled

4
SXR Frame fixing

TECHNICAL DATA

Frame fixings / Stand-off installation


SXR-Z▪-▪with▪zinc-plated▪fischer▪safety▪screw▪
for▪Cross▪drive▪PZ-bit

Drill hole Min. drill-hole Effect. Anchor Max. fixture Screw Drive Sales
Items to order only Approval diameter depth for through anchoring depth length thickness unit
fixings
do h2 hnom (hv) l t fix
Item Art.-No. ETA [mm] [mm] [mm] [mm] [mm] [pcs]
SXR 6 x 60 Z 503233 6 70 30 60 30 - PZ2 50
SXR 8 x 60 Z 505261 8 70 50 60 10 - PZ3 50
SXR 8 x 80 Z 505262 8 90 50 60 30 - PZ3 50
SXR 8 x 100 Z 505263 8 110 50 100 50 - PZ3 50
SXR 8 x 120 Z 505264 8 130 50 120 70 PZ3 50
SXR 10 x 80 Z 47977 ■ 10 90 50 80 30 7 x 87 PZ4 50
SXR 10 x 100 Z 47978 ■ 10 110 50 100 50 7 x 107 PZ4 50
SXR 10 x 120 Z 47979 ■ 10 130 50 120 70 7 x 127 PZ4 50
SXR 10 x 140 Z 47980 ■ 10 150 50 140 90 7 x 147 PZ4 50
SXR 10 x 160 Z 47981 ■ 10 170 50 160 110 7 x 167 PZ4 50
1) not pre-assembled

TECHNICAL DATA
3
SXR-FUS▪-▪with▪fischer▪hexagon▪safety▪
screw,▪moulded-on▪washer▪and▪integrated▪
bit▪T40

zinc-plated stainless Hot-dip Drill hole Min. drill- Min. Anchor Max. fixture Drive Sales unit
steel steel galvanised diameter hole depth embedment length thickness
Approval

Items to order only


steel for through depth
fixings
do h2 hnom (hv) l t fix
Art.-No. Art.-No. Art.-No. DIBt ETA [mm] [mm] [mm] [mm] [mm] [pcs]
Item gvz A4 fvz
SXR 10 x 52 FUS 502456 1) — — ▯ ■ 10 62 50 52 2 T40/SW13 50
SXR 10 x 60 FUS 046329 046339 — ▯ ■ 10 70 50 60 10 T40/SW13 50
SXR 10 x 60 FUS — — 509537 — — 10 70 50 60 10 T40/SW13 50
SXR 10 x 80 FUS 046330 046340 — ▯ ■ 10 90 50 80 30 T40/SW13 50
SXR 10 x 80 FUS — — 509538 — — 10 90 50 80 30 T40/SW13 50
SXR 10 x 100 FUS 046331 046342 — ▯ ■ 10 110 50 100 50 T40/SW13 50
SXR 10 x 100 FUS — — 509539 — — 10 110 50 100 50 T40/SW13 50
SXR 10 x 120 FUS 046332 046343 — ▯ ■ 10 130 50 120 70 T40/SW13 50
SXR 10 x 140 FUS 046333 046344 — ▯ ■ 10 150 50 140 90 T40/SW13 50
SXR 10 x 140 FUS — — 509540 — — 10 150 50 140 90 T40/SW13 50
SXR 10 x 160 FUS 046334 046345 — ▯ ■ 10 170 50 160 110 T40/SW13 50
SXR 10 x 180 FUS 046335 046361 — ▯ ■ 10 190 50 180 130 T40/SW13 50
SXR 10 x 200 FUS 046336 — — ▯ ■ 10 210 50 200 150 T40/SW13 50
SXR 10 x 200 FUS — 046362 — ▯ ■ 10 210 50 200 150 SW13 50
SXR 10 x 230 FUS 046337 — — ▯ ■ 10 240 50 230 180 T40/SW13 50
SXR 10 x 230 FUS — 046363 — ▯ ■ 10 240 50 230 180 SW13 50
SXR 10 x 260 FUS 046338 — — ▯ ■ 10 270 50 260 210 T40/SW13 50
SXR 10 x 260 FUS — 046364 — ▯ ■ 10 270 50 260 210 SW13 50
1) not pre-assembled

5
SXR Frame fixing

ACCESSORIES
Frame fixings / Stand-off installation

Cover▪cap▪ADT

Items to order only Colour Cap Fits safety screw with seat ITX-Star recess Sales unit
[Ø mm] [pcs]
Item Art.-No.
ADT 15 W 060326 white 15 40 100
ADT 15 DB 060329 dark brown 15 40 100
ADT 18 W 060334 white 18 40 100
ADT 18 DB 060337 dark brown 18 40 100

Washer▪U
stainless▪steel▪A2

External Hole Ø Thickness Fits anchor Sales


Item to order only
unit
Item Art.-No. [mm] [Ø mm] [mm] [pcs]
U 11,5 x 21 x 1,5 DIN 522 A2 010026 21 11,5 1,5 SXR 10, FUR 10, SXS 10 500

ACCESSORIES

Aircrete▪hole▪
punch▪GBS

3 Items to order only


Drill-hole Min. drill-hole depth for
through fixings
Fits Sales
unit
Item Art.-No. [Ø mm] [mm] [pcs]
GBS 10 x 80 050590 1) 9 85 SXR 10 x 52, SXR 10 x 60, SXR 10 x 80 1
GBS 10 x 100 050591 1) 9 105 SXR 10 x 100 1
GBS 10 x 135 050593 1) 9 140 SXR 10 x 120 1
GBS 10 x 160 050594 1) 9 165 SXR 10 x 140, SXR 10 x 160 1
GBS 10 x 185 050595 1) 9 190 SXR 10 x 180 1
GBS 10 x 230 050596 1) 9 235 SXR 10 x 200, SXR 10 x 230 1
1) According to the approval, the Aircrete hole punch GBS must be used for drill-hole production in aerated concrete.

LOADS
Frame fixing SXR 4)
Highest▪permissible▪loads1)▪for▪a▪single▪anchor▪for▪multiple▪fixings▪of▪non-structural▪applications▪in▪normal▪concrete▪≥▪C12/15▪resp.▪≥▪
B15.▪For▪the▪design▪the▪complete▪approval▪ETA-07/0121▪has▪to▪be▪considered.

Cracked or Non-cracked concrete


Type Min. Min. Permissible Permissible Min. spacing Min. edge
embedment depth substrate thickness tensile load shear load distance
hnom (hv) hmin Nperm6) Vperm6) smin2) cmin2)
[mm] [mm] [kN] [mm] [mm]
SXR 8 50 100 1,0 4,2 (3,4) 5) 50 50
SXR 10 50 100 1,8 5,4 (5,0) 5) 50 100
1)
The required partial safety factors for material resistance as well as a partial safety factor for load actions of γL = 1,4 are considered.
2)
Minimum possible axial spacings resp. edge distance for concrete ≥ C16/20 while reducing the permissible load.
3)
For combinations of tensile loads, shear loads, bending moments as well as reduced edge distances or spacings (anchor groups) see approval.
4)
gvz and A4. For exterior applications measures against incoming humidity have to be taken.
5)
Values in brackets apply for A4-type - stainless steel of the corrosion resistance class III, e.g. A4.
6)
Valid for temperatures in the substrate up to +50°C (resp. short term up to 80°C). For long term temperatures up to 30°C higher permissible loads may be possible.

6
SXR Frame fixing

LOADS
Frame fixing SXR 4)

Frame fixings / Stand-off installation


Highest▪permissible▪loads1)▪for▪a▪single▪anchor▪for▪multiple▪fixings▪of▪facades▪in▪masonry.
For▪the▪design▪the▪complete▪approval▪Z-21.2-1862▪has▪to▪be▪considered.

Solid brick masonry and Perforated brick masonry


Type Compressive Brick type, Min. Min. Permissible Min. Min.
brick strength naming acc. DIN embedment depth substrate thickness load spacing edge distance
fb hnom (hv) h (d) Fperm3) 5) smin (amin)2) cmin (ar)6)
[N/mm²] [-] [mm] [mm] [kN] [mm] [mm]
Solid brick Mz
SXR 8 ≥ 12 Mz 50 115 0,50 100 100
SXR10 ≥ 12 Mz 50 115 0,80 100 100
Solid sand-lime brick and solid block KS
SXR 8 ≥ 12 KS 50 115 0,50 100 100
SXR10 ≥ 12 KS 50 115 0,80 100 100
Vertically perforated brick Hlz
SXR 8 ≥ 12 HLz 50 115 - 100 100
SXR10 ≥ 12 HLz 50 115 0,37) 250 100
Perforated sand-lime brick KSL
SXR 8 ≥6 KSL 50 115 - 100 100
SXR10 ≥6 KSL 50 115 0,40 100 100
Hollow block of lightweight aggregate concrete Hbl
SXR 8 ≥6 Hbl 50 115 - 100 100
SXR10 ≥6 Hbl 50 115 0,25 250 100
Solid brick and solid block of lightweight aggregate concrete V
SXR 8 ≥2 V 50 115 0,15 100 100
SXR10 ≥2 V 50 115 0,25 100 100
Aerated concrete block PB2/ PP2 as well as wall panels of aerated concrete P3.3 with approval
SXR10 ≥2 PB2/PP2/P2,2 50 115 0,28) 150 1008)
Aerated concrete block ≥ PB4/PP4 as well as wall panels of aerated concrete≥ P4.4 with approval 3
SXR10 ≥ 3/ ≥ 4,4 PP3/PB3/P4,4 50 115 0,30 200 1008)

1)
The required safety factors as regulated in the approval are considered. 5)
The given values apply for rotary drilling (without impact) in perforated bricks and
2)
Minimum permissible spacing without reducing the permissible load. In certain cases aerated concrete.
the spacing within pairs of anchors may be reduced up to 100 mm while reducing the 6)
Minimum permissible edge distance with surcharge as well as to not solidified joints.
permissible load. For edge distance without surcharge see approval.
3)
Valid for tensile load, shear load and oblique load under any angle. Restrictions for 7)
Valid for raw density higher than 1,0 kg/dm³. Otherwise the permissible load has to
permanently acting tensile loads see approval. For combinations of tensile loads, be determined by tests on site.
shear loads, bending moments see approval table 4. 8)
Drill hole created by punching.
4)
gvz and A4. For exterior applications of galvanised screws measures against incoming
humidity have to be taken.

7
SXR Frame fixing

LOADS
Frame fixing SXR 4)
Frame fixings / Stand-off installation

Highest▪permissible▪loads1)▪for▪a▪single▪anchor▪for▪multiple▪fixings▪of▪non-structural▪applications▪in▪masonry.
For▪the▪design▪the▪complete▪approval▪ETA-07/0121▪has▪to▪be▪considered.
Solid brick masonry and perforated brick masonry
Type Compressive Brick type, Min. Min. Permissible Min. Min. edge
brick strength naming acc. DIN embedment depth substrate thickness load spacing distance
fb hnom (hv) hmin Fperm3) 5) 6) smin2) cmin2)
[N/mm²] [-] [mm] [mm] [kN] [mm] [mm]
Solid brick Mz
SXR 8 ≥ 20 Mz 50 100 0,70 100 100
SXR10 ≥ 20 Mz 50 100 1,29 100 100
Solid sand-lime brick and solid block KS
SXR 8 ≥ 10 KS 50 100 0,70 100 100
SXR10 ≥ 10 KS 50 100 1,29 100 100
Vertically perforated brick Hlz
SXR 8 ≥6 HLz 50 100 0,34 100 100
SXR10 ≥6 HLz 50 100 0,57 100 100
Perforated sand-lime brick KSL
SXR 8 ≥ 12 KSL 50 100 0,57 100 100
SXR10 ≥ 12 KSL 50 100 0,70 100 100
Hollow block of lightweight aggregate concrete Hbl
SXR 8 ≥ 10 Hbl 50 100 0,70 100 100
SXR10 ≥ 10 Hbl 50 100 0,70 100 100
Solid brick and solid block of lightweight aggregate concrete V
SXR 8 ≥2 V 50 100 0,70 100 100
SXR10 ≥2 V 50 100 0,85 100 100
Aerated concrete block PB2/ PP2
SXR10 ≥2 PP2/PB2/P2,2 50 100 0,157) 200 100
Aerated concrete block ≥ PB4/PP4
3 SXR10
1)
≥ 3/ ≥ 4,4 PP3/PB3/P4,4
The required partial safety factors for material resistance as well as a partial safety factor for
50
5)
100 0,26 200 100
The given values apply for rotary drilling (without impact). The given loads are reference values
load actions of γL = 1,4 are considered. which may change due to type of brick and manufacturer.
2)
Minimum possible axial spacing (anchor group) while reducing the permissible load. 6)
Valid for temperatures in the substrate up to +50°C (resp. short term up to 80°C). For long term
3)
Valid for tensile load, shear load and oblique load under any angle. For combinations of tensile temperatures up to 30°C higher permissible loads may be possible.
loads, shear loads and bending moments see approval. 7)
Drill hole created by punching.
4)
gvz and A4. For exterior applications of galvanised screws measures against incoming humidity
have to be taken.

LOADS
Frame fixing SXR
Highest▪recommended▪loads1)▪for▪a▪single▪anchor.
The▪given▪loads▪are▪valid▪for▪wood▪screws▪with▪the▪specified▪diameter.
Type SXR 6

Screw diameter Ø [mm] 4,5


Min. edge distance in concrete ar [mm] 50
Recommended loads in the respective base material Frec2)
Concrete ≥ C20/25 [kN] 0,25
Solid brick ≥ Mz 12 [kN] 0,20
Solid sand-lime brick ≥ KS 12 [kN] 0,20
Vertically perforated brick ≥ Hlz 12 (ρ ≥ 1.0 kg/dm³) [kN] 0,10
Perforated sand-lime brick ≥ KSL 12 [kN] 0,20
1)
Required safety factors are considered.
2)
Valid for tensile load, shear load and oblique load under any angle.

8
FUR Universal frame fixing
The user-friendly problem solver for a large range of building
materials

Frame fixings / Stand-off installation


Façade sub-structures Wood constructions

VERSIONS APPROVALS
▪▪ Zinc-plated▪steel
▪▪ Stainless▪steel

BUILDING MATERIALS
Approved for:
▪▪ Concrete▪≥▪C12/15
▪▪ Three-layer▪composite▪exterior▪wall▪
panels
▪▪ Lightweight▪aggregate▪concrete
▪▪ Vertically▪perforated▪brick
▪▪ Hollow▪block▪made▪from▪lightweight▪
concrete
▪▪ Perforated▪sand-lime▪brick
▪▪ Solid▪sand-lime▪brick
▪▪ Solid▪block▪made▪from▪lightweight▪
concrete
3
▪▪ Solid▪brick
Also suitable for:
▪▪ Natural▪stone▪with▪dense▪structure
▪▪ Solid▪panel▪made▪from▪gypsum

ADVANTAGES APPLICATIONS FUNCTIONING


▪▪ The▪ universal▪ operating▪ principle▪ with▪ ▪▪ Façade▪and▪roof▪sub-structures▪made▪ ▪▪ The▪FUR▪is▪for▪push-through▪installation.
an▪ anchorage▪ depth▪ of▪ 70  mm▪ and▪ of▪wood▪and▪metal ▪▪ Installing▪ the▪ screw▪ causes▪ the▪
unique▪ asymmetrical▪ teeth▪ allows▪ for▪ ▪▪ Windows individual▪ teeth▪ to▪ expand.▪ In▪ solid▪
use▪ in▪ all▪ solid▪ and▪ hollow▪ building▪ ▪▪ Squared▪timbers materials,▪ the▪ teeth▪ create▪ even▪
materials.▪As▪such,▪the▪FUR▪is▪the▪right▪ ▪▪ Gates▪and▪doors expansion▪ forces.▪ In▪ hollow▪ materials,▪
choice▪ for▪ projects▪ with▪ an▪ unknown▪ ▪▪ Claddings the▪teeth▪expand▪through▪the▪solid▪part▪
base▪material;▪ensuring▪a▪secure▪fixing▪ ▪▪ Interior▪fittings of▪ the▪ block▪ and▪ form▪ an▪ undercut▪ in▪
at▪all▪times. the▪cavity.
▪▪ The▪slim▪geometry▪guarantees▪a▪simple▪ ▪▪ With▪ vertically▪ perforated▪ bricks,▪ only▪
installation,▪ even▪ in▪ cases▪ involving▪ use▪rotary▪drilling▪(no▪impact▪drilling).
thick▪wooden▪fixtures▪and▪narrow▪drill▪ ▪▪ Countersunk▪ head▪ screws▪ are▪
holes. recommended▪ for▪ the▪ installation▪ of▪
▪▪ The▪ FUR  14▪ fulfils▪ the▪ highest▪ timber▪ constructions;▪ in▪ the▪ case▪ of▪
requirements▪ in▪ terms▪ of▪ maximum▪ metal▪constructions,▪use▪anchors▪with▪
usage▪ lengths▪ and▪ shear▪ loads.▪ As▪ a▪ hexagon-head▪ screws▪ and▪ moulded▪
result,▪it▪is▪suitable▪for▪a▪wide▪range▪of▪ washers.
applications.

INSTALLATION

9
FUR Universal frame fixing

TECHNICAL DATA
Frame fixings / Stand-off installation

FUR-T▪-▪safety▪screw▪with▪countersunk▪head

zinc-plated stainless Drill hole Min. drill-hole depth for Min. embedment Anchor Max. fixture Drive Sales

Approval
Items to order only steel steel diameter through fixings depth length thickness unit

do h2 hnom (hv) l t fix


Art.-No. Art.-No. DIBt [mm] [mm] [mm] [mm] [mm] [pcs]
Item gvz A4
FUR 8 x 80 T 070110 070120 ▯ 8 90 70 80 10 T30 50
FUR 8 x 100 T 070111 070121 ▯ 8 110 70 100 30 T30 50
FUR 8 x 120 T 070112 070122 ▯ 8 130 70 120 50 T30 50
FUR 10 x 80 T 088756 088784 ▯ 10 90 70 80 10 T40 50
FUR 10 x 100 T 088757 088785 ▯ 10 110 70 100 30 T40 50
FUR 10 x 115 T 088760 088791 ▯ 10 125 70 115 45 T40 50
FUR 10 x 135 T 088758 088786 ▯ 10 145 70 135 65 T40 50
FUR 10 x 160 T 088759 088787 ▯ 10 170 70 160 90 T40 50
FUR 10 x 185 T 088761 088788 ▯ 10 195 70 185 115 T40 50
FUR 10 x 200 T 088764 088789 ▯ 10 210 70 200 130 T40 50
FUR 10 x 230 T 088762 088790 ▯ 10 240 70 230 160 T40 50
FUR 14 x 100 T 048711 — ▯ 14 115 70 100 30 T50 50
FUR 14 x 140 T 048712 048719 ▯ 14 155 70 140 70 T50 50
FUR 14 x 165 T 048713 048720 ▯ 14 180 70 165 95 T50 50
FUR 14 x 180 T 048714 048721 ▯ 14 195 70 180 110 T50 50
FUR 14 x 210 T 048844 048845 ▯ 14 225 70 210 140 T50 50
FUR 14 x 240 T 048715 — ▯ 14 255 70 240 170 T50 50
3 FUR 14 x 270 T
FUR 14 x 300 T
048716
090759




14
14
285
315
70
70
270
300
200
230
T50
T50
50
20
FUR 14 x 330 T 090760 — ▯ 14 345 70 330 260 T50 20
FUR 14 x 360 T 090761 — ▯ 14 375 70 360 290 T50 20

TECHNICAL DATA

FUR 8-SS▪and▪FUR 10-SS▪-▪safety▪screw▪


with▪hexagon-head

zinc-plated stainless Drill hole Min. drill-hole depth for Min. embedment Anchor Max. fixture Width Sales
Approval

Items to order only steel steel diameter through fixings depth length thickness across nut unit

do h2 hnom (hv) l t fix  SW


Art.-No. Art.-No. DIBt [mm] [mm] [mm] [mm] [mm] [mm] [pcs]
Item gvz A4
FUR 8 x 80 SS 070130 070140 ▯ 8 90 70 80 10 10 50
FUR 8 x 100 SS 070131 070141 ▯ 8 110 70 100 30 10 50
FUR 8 x 120 SS 070132 — ▯ 8 130 70 120 50 10 50
FUR 10 x 80 SS 088776 088792 ▯ 10 90 70 80 10 13 50
FUR 10 x 100 SS 088777 088793 ▯ 10 110 70 100 30 13 50
FUR 10 x 115 SS 088783 088799 ▯ 10 125 70 115 45 13 50
FUR 10 x 135 SS 088778 088794 ▯ 10 145 70 135 65 13 50
FUR 10 x 160 SS 088779 088795 ▯ 10 170 70 160 90 13 50
FUR 10 x 185 SS 088780 088796 ▯ 10 195 70 185 115 13 50
FUR 10 x 200 SS 088781 088797 ▯ 10 210 70 200 130 13 50
FUR 10 x 230 SS 088782 088798 ▯ 10 240 70 230 160 13 50

10
FUR Universal frame fixing

TECHNICAL DATA

Frame fixings / Stand-off installation


FUR 14 F US▪-▪safety▪screw▪with▪hexagon-
head▪and▪integrated▪washer

zinc-plated stainless Drill hole Min. drill-hole depth Min. embedment Anchor Max. fixture Width Sales

Approval
Items to order only steel steel diameter for through fixings depth length thickness across nut unit

do h2 hnom (hv) l t fix  SW


Art.-No. Art.-No. DIBt [mm] [mm] [mm] [mm] [mm] [mm] [pcs]
Item gvz A4
FUR 10 x 80 FUS 093527 2) 4) 093528 2) 4) ▯ 10 90 70 80 10 13 50
FUR 10 x 100 FUS 097797 2) 4) — ▯ 10 80 70 100 30 13 50
FUR 14 x 80 FUS 048724 3) 048731 3) ▯ 14 95 70 80 10 17 50
FUR 14 x 100 FUS 048725 3) 048732 3) ▯ 14 115 70 100 30 17 50
FUR 14 x 140 FUS 048726 3) 048733 3) ▯ 14 155 70 140 70 17 50
FUR 14 x 165 FUS 048727 3) 048734 3) ▯ 14 180 70 165 95 17 50
FUR 14 x 180 FUS 048728 1) 3) 048735 1) 3) ▯ 14 195 70 180 110 17 50
FUR 14 x 210 FUS 048842 1) 3) 048843 1) 3) ▯ 14 225 70 210 140 17 50
FUR 14 x 240 FUS 048729 1) 3) 048736 1) 3) ▯ 14 255 70 240 170 17 50
FUR 14 x 270 FUS 048730 3) 048737 3) ▯ 14 285 70 270 200 17 50
1) With washer according to DIN 125.
2) Collar: Ø 18 x 2 mm.
3) Collar: Ø 26 x 3 mm.
4) Additional Bit T40 is integrated into the hexagon head.

ACCESSORIES
3
Cover▪cap▪ADT

Items to order only Colour Cap Fits safety screw with seat ITX-Star recess Sales unit
[Ø mm] [pcs]
Item Art.-No.
ADT 15 W 060326 white 15 40 100
ADT 15 DB 060329 dark brown 15 40 100
ADT 18 W 060334 white 18 40 100
ADT 18 DB 060337 dark brown 18 40 100

11
FUR Universal frame fixing

LOADS
Universal frame fixing FUR 4)
Frame fixings / Stand-off installation

Highest▪permissible▪loads1)▪for▪a▪single▪anchor▪for▪multiple▪fixings▪of▪non-structural▪applications▪in▪normal▪concrete▪≥▪C12/15▪resp.▪≥▪
B155).▪For▪the▪design▪the▪complete▪approval▪Z-21.2-1204▪has▪to▪be▪considered.
Cracked or Non-cracked concrete
Type Min. embedment depth Min. substrate thickness Permissible load Min. spacing Min. edge distance

hnom (hv) h (d) Fperm3) smin (a) 2) cmin (ar) 2)


[mm] [mm] [kN] [mm] [mm]
FUR 8 70 100 1,0 50 50
FUR 10 70 120 1,6 50 50
FUR 14 70 120 1,8 50 60
1)
The required safety factors as regulated in the approval are considered. 4)
gvz and A4. For exterior applications of galvanised screws measures against incoming humidity
2)
Minimum possible axial spacings resp. edge distance while reducing the permissible load. have to be taken.
3)
Valid for tensile load, shear load and oblique load under any angle. Restrictions for permanently 5)
Permissible loads in the weather shell of triple-skin outer wall panels as well as in no-fines
acting tensile loads see approval. For combinations of tensile loads, shear loads, bending lightweight concrete see approval.
moments see approval table 4.

LOADS
Universal frame fixing FUR 4)
Highest▪permissible▪loads1)▪for▪a▪single▪anchor▪for▪multiple▪fixings▪of▪facades▪in▪masonry.
For▪the▪design▪the▪complete▪approval▪Z-21.2-1204▪has▪to▪be▪considered.
Solid brick masonry and perforated brick masonry
Type Compressive Brick type, Min. Min. Permissible load Min. Min.
brick strength naming acc. DIN embedment depth substrate thickness spacing edge distance
fb hnom (hv) h (d) Fperm3) 5) smin (a) 2) cmin (ar) 6)
[N/mm²] [-] [mm] [mm] [kN] [mm] [mm]
Solid brick Mz
FUR 8 ≥ 12 Mz 70 115 0,60 100 100
3 FUR 10
FUR 14
≥ 12
≥ 12
Mz
Mz
70
70
115
115
0,80
0,80
100
250
100
100
Solid sand-lime brick and solid block KS
FUR 8 ≥ 12 KS 70 115 0,60 100 100
FUR 10 ≥ 12 KS 70 115 0,80 100 100
FUR 14 ≥ 12 KS 70 115 0,80 250 100
Vertically perforated brick Hlz
FUR 8 ≥ 12 HLz 70 115 - 100 100
FUR 10 ≥ 12 HLz 70 115 0,37) 250 100
FUR 14 ≥ 12 HLz 70 115 0,57) 250 100
Perforated sand-lime brick KSL
FUR 8 ≥6 KSL 70 115 - 100 100
FUR 10 ≥6 KSL 70 115 0,40 250 100
FUR 14 ≥6 KSL 70 115 0,60 250 100
Hollow block of lightweight aggregate concrete Hbl
FUR 8 ≥2 Hbl 708) 115 - 100 100
FUR 10 ≥2 Hbl 708) 115 0,25 250 100
FUR 14 ≥2 Hbl 708) 115 0,30 250 100
Solid brick and solid block of lightweight aggregate concrete
FUR 8 ≥2 V 70 115 - 100 100
FUR 10 ≥2 V 70 115 0,25 100 100
FUR 14 ≥2 V 70 115 0,50 250 100
1)
The required safety factors as regulated in the approval are considered. 5)
The given values apply for rotary drilling in perforated bricks (without impact).
2)
Minimum permissible spacing without reducing the permissible load. 6)
Minimum permissible edge distance with surcharge as well as to not solidified joints. For edge
3)
Valid for tensile load, shear load and oblique load under any angle. Restrictions for permanently distance without surcharge see approval.
acting tensile loads see approval. For combinations of tensile loads, shear loads, bending 7)
Valid for raw density higher than 1,0 kg/dm³. Otherwise the permissible load has to be deter-
moments see approval table 4. mined by tests on site.
4)
gvz and A4. For exterior applications of galvanised screws measures against incoming humidity 8)
The expansion part of the plug must be located in the web of the brick (see approval, appendix 6).
have to be taken.

12
FUR Universal frame fixing

LOADS
Universal frame fixing FUR 4)

Frame fixings / Stand-off installation


Highest▪permissible▪loads1)▪for▪a▪single▪anchor▪for▪multiple▪fixings▪of▪facades▪in▪masonry.
For▪the▪design▪the▪complete▪approval▪Z-21.2-1204▪has▪to▪be▪considered.
Solid brick masonry and perforated brick masonry
Type Compressive Brick type, Min. Min. Permissible load Min. Min.
brick strength naming acc. DIN embedment depth substrate thickness spacing edge distance
fb hnom (hv) h (d) Fperm3) 5) smin (a) 2) cmin (ar) 6)
[N/mm²] [-] [mm] [mm] [kN] [mm] [mm]
Solid brick Mz
FUR 8 ≥ 12 Mz 70 115 0,60 100 100
FUR 10 ≥ 12 Mz 70 115 0,80 100 100
FUR 14 ≥ 12 Mz 70 115 0,80 250 100
Solid sand-lime brick and solid block KS
FUR 8 ≥ 12 KS 70 115 0,60 100 100
FUR 10 ≥ 12 KS 70 115 0,80 100 100
FUR 14 ≥ 12 KS 70 115 0,80 250 100
Vertically perforated brick Hlz
FUR 8 ≥ 12 HLz 70 115 - 100 100
FUR 10 ≥ 12 HLz 70 115 0,37) 250 100
FUR 14 ≥ 12 HLz 70 115 0,57) 250 100
Perforated sand-lime brick KSL
FUR 8 ≥6 KSL 70 115 - 100 100
FUR 10 ≥6 KSL 70 115 0,40 250 100
FUR 14 ≥6 KSL 70 115 0,60 250 100
Hollow block of lightweight aggregate concrete Hbl
FUR 8 ≥2 Hbl 708) 115 - 100 100
FUR 10 ≥2 Hbl 708) 115 0,25 250 100
FUR 14 ≥2 Hbl 708) 115 0,30 250 100
Solid brick and solid block of lightweight aggregate concrete
FUR 8
FUR 10
≥2
≥2
V
V
70
70
115
115
-
0,25
100
100
100
100
3
FUR 14 ≥2 V 70 115 0,50 250 100
1)
The required safety factors as regulated in the approval are considered. 5)
The given values apply for rotary drilling in perforated bricks (without impact).
2)
Minimum permissible spacing without reducing the permissible load. 6)
Minimum permissible edge distance with surcharge as well as to not solidified joints. For edge
3)
Valid for tensile load, shear load and oblique load under any angle. Restrictions for permanently distance without surcharge see approval.
acting tensile loads see approval. For combinations of tensile loads, shear loads, bending 7)
Valid for raw density higher than 1,0 kg/dm³. Otherwise the permissible load has to be deter-
moments see approval table 4. mined by tests on site.
4)
gvz and A4. For exterior applications of galvanised screws measures against incoming humidity 8)
The expansion part of the plug must be located in the web of the brick (see approval, appendix 6).
have to be taken.

13
SXS frame fixing
The high-performance frame fixing for solid building materials
and cracked concrete
Frame fixings / Stand-off installation

Cable trays Façade sub-structures

VERSIONS APPROVALS
▪▪ Zinc-plated▪steel
▪▪ Stainless▪steel

BUILDING MATERIALS
Approved for:
▪▪ Concrete▪C20/25▪to▪C50/60
▪▪ Three-layer▪ composite▪ exterior▪ wall▪
panels
▪▪ Hollow▪ block▪ made▪ from▪ lightweight▪
concrete
▪▪ Solid▪sand-lime▪brick
▪▪ Aerated▪concrete
▪▪ Solid▪brick
Also suitable for:
3 ▪▪ Natural▪stone▪with▪dense▪structure
▪▪ Solid▪ block▪ made▪ from▪ lightweight▪
concrete
▪▪ Solid▪panel▪made▪from▪gypsum
▪▪ Concrete▪C12/15

ADVANTAGES APPLICATIONS FUNCTIONING


▪▪ The▪ideal▪combination▪of▪the▪SXS▪with▪ ▪▪ Façade▪and▪roof▪sub-structures▪made▪ ▪▪ The▪ SXS▪ is▪ for▪ a▪ push-through▪
the▪ CO-NA▪ screw▪ enables▪ high▪ load- of▪wood▪and▪metal installation.▪Screwing▪in▪of▪the▪CO-NA▪
bearing▪ capacities▪ in▪ solid▪ building▪ ▪▪ Windows screw▪causes▪the▪SXS▪to▪expand▪in▪four▪
materials▪and▪aerated▪concrete.▪ ▪▪ Fire▪protection▪doors directions▪which▪securely▪anchors▪into▪
▪▪ The▪ CO-NA▪ screw▪ works▪ by▪ making▪▪ ▪▪ Guard▪rails the▪building▪material.
the▪plug▪expand▪within▪the▪crack.▪This▪ ▪▪ Handrails ▪▪ When▪ a▪ crack▪ forms▪ in▪ the▪ concrete,▪
is▪the▪first▪plastic▪frame▪fixing▪to▪receive▪ ▪▪ Squared▪timbers the▪cones▪of▪the▪screw▪actively▪expand,▪
an▪approval▪for▪single▪fixings. ▪▪ Kitchen▪cabinets thus▪ increasing▪ the▪ expansion▪ effect▪
▪▪ The▪large▪diameter▪of▪the▪CO-NA▪screw▪ ▪▪ Gates and▪the▪holding▪force▪of▪the▪plug.
means▪ that▪ high▪ shear▪ loads▪ can▪ be▪ ▪▪ Countersunk▪ head▪ screws▪ are▪
supported▪safely▪therefore▪fewer▪fixing▪ recommended▪ for▪ the▪ installation▪ of▪
points▪are▪required. timber▪ constructions;▪ in▪ the▪ case▪ of▪
metal▪ constructions,▪ use▪ plugs▪ with▪ a▪
wide▪sleeve▪rim▪and▪a▪moulded▪washer▪
on▪ the▪ screw,▪ which▪ also▪ features▪ an▪
integrated▪hexagon▪socket.

INSTALLATION

14
SXS frame fixing

TECHNICAL DATA

Frame fixings / Stand-off installation


SXS-T▪-▪with▪CO-NA▪screw▪and▪countersunk▪
head

zinc-plated stainless Drill hole Min. embedment Anchor length Max. fixture Min. drill hole Drive Sales

Approval
Items to order only
steel steel diameter depth thickness depth unit
do hnom (hv) l t fix td
Art.-No. Art.-No. DIBt ETA [mm] [mm] [mm] [mm] [mm] [pcs]
Item gvz A4
SXS 10 x 80 T 019601 019602 ▯ ■ 10 50 80 30 90 T40 50
SXS 10 x 100 T 019604 019605 ▯ ■ 10 50 100 50 110 T40 50
SXS 10 x 120 T 019616 019617 ▯ ■ 10 50 120 70 130 T40 50
SXS 10 x 140 T 019621 019623 ▯ ■ 10 50 140 90 150 T40 50
SXS 10 x 160 T 024076 024077 ▯ ■ 10 50 160 110 170 T40 50
SXS 10 x 180 T 024080 024082 ▯ ■ 10 50 180 130 190 T40 50

TECHNICAL DATA

SXS-F US▪with▪CO-NA▪hexagon-head▪screw▪
with▪integrated▪washer

3
zinc-plated stainless Drill hole Min. embedment Anchor Max. fixture Min. drill hole Width across Sales
Approval

Items to order only


steel steel diameter depth length thickness depth nut unit
do hnom (hv) l t fix td  SW
Art.-No. Art.-No. DIBt ETA [mm] [mm] [mm] [mm] [mm] [mm] [pcs]
Item gvz A4
SXS 10 x 60 F US 019599 1) 019600 1) ▯ ■ 10 50 60 10 70 13 50
SXS 10 x 80 F US 019603 1) 019628 1) ▯ ■ 10 50 80 30 90 13 50
SXS 10 x 100 F US 019614 1) 019615 1) ▯ ■ 10 50 100 50 110 13 50
SXS 10 x 120 F US 019619 1) 019620 1) ▯ ■ 10 50 120 70 130 13 50
SXS 10 x 140 F US 019624 1) 019626 1) ▯ ■ 10 50 140 90 150 13 50
SXS 10 x 160 F US 024045 1) 024062 1) ▯ ■ 10 50 160 110 170 13 50
SXS 10 x 180 F US 024046 1) 024063 1) ▯ ■ 10 50 180 130 190 13 50
1) Collar: Ø 18 x 2 mm, CO-NA hexagon-head screw with integrated washer and additional  - T40 integrated into the hexagon head.

ACCESSORIES

Cover▪cap▪ADT

Items to order only Colour Cap Seat ITX-Star recess Sales unit
Item Art.-No. [Ø mm] [pcs]
ADT 15 W 060326 white 15 TX40 100
ADT 15 DB 060329 dark brown 15 TX40 100
ADT 18 W 060334 white 18 TX40 100
ADT 18 DB 060337 dark brown 18 TX40 100

15
SXS frame fixing

ACCESSORIES
Frame fixings / Stand-off installation

Washer▪U▪stainless▪steel▪A2

External Hole Ø Thickness Fits anchor Sales unit


Item to order only
d S
Item Art.-No. [mm] [Ø mm] [mm] [pcs]
U 11,5 x 21 x 1,5 DIN 522 A2 010026 21 11,5 1,5 SXR 10, FUR 10, SXS 10 500
LOADS
Frame fixing SXS 4)
Highest▪permissible▪loads1)▪for▪a▪single▪anchor▪for▪multiple▪fixings▪of▪non-structural▪applications▪in▪normal▪concrete▪≥▪C16/20▪resp.▪≥ B207).▪For▪
the▪design▪the▪complete▪approval▪ETA-09/0352▪has▪to▪be▪considered.
Cracked or Non-cracked concrete
Type Min. Min. Permissible Permissible Min. Min.
embedment depth substrate thickness tensile load shear load spacing edge distance
hnom (hv) hmin Nperm3) 6) Vperm3) 6) smin2) cmin2)
[mm] [mm] [kN] [kN] [mm] [mm]
SXS 10 50 100 2,0 5,4 55 100
1)
The required partial safety factors for material resistance as well as a partial safety factor for 4)
gvz and A4. For exterior applications of galvanised screws measures against incoming humidity
load actions of γL = 1,4 are considered. have to be taken.
2)
Minimum possible axial spacings resp. edge distance (anchor group) while reducing the permissi- 6)
Valid for temperatures in the substrate up to +50°C (resp. short term up to 80°C). For long term
ble load. temperatures up to 30°C higher permissible loads may be possible.
3)
For combinations of tensile loads, shear loads, bending moments as well as reduced edge 7)
Values for concrete C12/15 see approval.
distances or spacings (anchor groups) see approval.

LOADS
Frame fixing SXS 4)
Highest▪permissible▪loads1)▪for▪a▪single▪anchor▪in▪normal▪concrete▪≥▪C20/25▪resp.▪≥▪B25.
For▪the▪design▪the▪complete▪approval▪Z-21.2-1734▪has▪to▪be▪considered.
Cracked concrete Non-cracked concrete
3 Type Min. embed-
ment depth
Min.
substrate
Permissible Permissible Min. spacing Min. edge
tensile load shear load distance
Permissible Permissible Min. spacing Min. edge
tensile load shear load distance
thickness
hnom (hv) hmin Nperm6) Vperm6) smin2) cmin2) Nperm6) Vperm6) smin2) cmin2)
[mm] [mm] [kN] [kN] [mm] [mm] [kN] [kN] [mm] [mm]
SXS 10 50 100 1,0 2,5 55 50 1,3 2,5 55 60
1)
The required partial safety factors for material resistance as well as a partial safety factor for 3)
For combinations of tensile loads, shear loads, bending moments as well as reduced edge
load actions of γL = 1,4 are considered. distances or spacings (anchor groups) see approval.
2)
Minimum possible axial spacings resp. edge distance (anchor group) while reducing the permissi- 4)
gvz and A4. For exterior applications of galvanised screws measures against incoming humidity
ble load. The combination of the given min. spacing and min. edge distance is not possible. One have to be taken.
of them has to be increased according approval. 6)
Valid for temperatures in the substrate up to +50°C (resp. short term up to 80°C). For long term
temperatures up to 30°C higher permissible loads may be possible.
LOADS
Frame fixing SXS 4)
Highest▪permissible▪loads1)▪for▪a▪single▪anchor▪for▪multiple▪fixings▪of▪facades▪in▪masonry.
For▪the▪design▪the▪complete▪approval▪Z-21.2-1695▪has▪to▪be▪considered.
Solid brick masonry and perforated brick masonry
Type Compressive Brick type, Min. Min. Permissible Min. Min.
brick strength naming acc. DIN embedment depth substrate thickness load spacing edge distance
fb hnom (hv) h (d) Fperm3) 5) smin (a)2) cmin (ar)6)
[N/mm²] [-] [mm] [mm] [kN] [mm] [mm]
Solid brick Mz
SXS10 ≥ 12 Mz 50 15,3 0,8 (0,60)9) 100 100
Solid sand-lime brick and solid block KS
SXS10 ≥ 12 KS 50 15,3 0,8 (0,60)9) 100 100
Hollow block of lightweight aggregate concrete Hbl
SXS10 ≥2 Hbl 508) 15,3 0,25 250 100
Solid brick and solid block of lightweight aggregate concrete V
SXS10 ≥2 V 50 15,3 0,25 100 100
1)
The required safety factors as regulated in the approval are considered. 5)
The given values apply for rotary drilling in perforated bricks (without impact).
2)
Minimum permissible spacing without reducing the permissible load. 6)
Minimum permissible edge distance with surcharge as well as to not solidified joints. For edge
3)
Valid for tensile load, shear load and oblique load under any angle. Restrictions for permanently distance without surcharge see approval.
acting tensile loads see approval. For combinations of tensile loads, shear loads, bending 8)
The expansion part of the plug must be located in the web of the brick (see approval, appendix 6).
moments see approval table 4. 9)
The higher values apply to solid bricks without handling pocket.
4)
gvz and A4. For exterior applications of galvanised screws measures against incoming humidity
have to be taken.

16
N Hammerfix
The hammer-in plug for a simple, fast and economical
installation

Frame fixings / Stand-off installation


Timber sub-structures Cable ducts

VERSIONS CHARACTERISTICS
▪▪ Zinc-plated▪steel
▪▪ Stainless▪steel

BUILDING MATERIALS
▪▪ Concrete
▪▪ Solid▪sand-lime▪brick
▪▪ Building▪brick
▪▪ Natural▪stone
▪▪ Solid▪block▪made▪from▪lightweight▪
concrete

ADVANTAGES APPLICATIONS FUNCTIONING


▪▪ The▪ rapid▪ hammerset▪ type▪ of▪ ▪▪ Sub-structures▪made▪of▪wood▪and▪ ▪▪ The▪ Hammerfix▪ N▪ is▪ a▪ push-through▪
installation▪reduces▪installation▪times.
▪▪ The▪ integrated▪ hammer-in▪ stop▪
metal
▪▪ Wall▪connection▪or▪plaster▪profiles
installation.
▪▪ When▪ hammered▪ in,▪ the▪ nail▪ screw▪
3
prevents▪ the▪ plug▪ from▪ expanding▪ ▪▪ Slides causes▪ the▪ plug▪ to▪ expand▪ in▪ two▪
prematurely▪ (jamming)▪ promoting▪ a▪ ▪▪ Sheets directions,▪ thus▪ providing▪ a▪ secure▪
problem-free▪installation. ▪▪ Cable▪and▪pipe▪clamps anchoring▪in▪the▪building▪material.
▪▪ Together,▪ the▪ cross-slot▪ recess▪ and▪ ▪▪ Punched▪tapes ▪▪ Countersunk▪ head▪ plugs▪ are▪
the▪ thread▪ enables▪ the▪ screw▪ to▪ recommended▪ for▪ the▪ installation▪ of▪
be▪ removed▪ allowing▪ for▪ potential▪ timber▪ constructions;▪ in▪ the▪ case▪ of▪
removal.▪With▪a▪wide▪range▪of▪different▪ metal▪ constructions,▪ use▪ flat-head▪
diameters,▪ lengths▪ and▪ head▪ shapes▪ plugs,▪and▪use▪pan-head▪plugs▪for▪long▪
the▪ hammerfix▪ can▪ be▪ used▪ in▪ many▪▪ holes.
applications.

INSTALLATION

17
N Hammerfix

TECHNICAL DATA
Frame fixings / Stand-off installation

Hammerfix▪N-Z▪with▪nail,▪pre-assembled

Hammerfix▪N-Z-A2▪with▪stainless▪steel▪A2▪
nail,▪pre-assembled

zinc-plated stainless Drill hole Effect. Anchor Min. drill-hole Max. fixture Sales
Items to order only steel steel A2 diameter anchoring depth length depth for through thickness unit
fixings
do hef l h2 t fix
Art.-No. Art.-No. [mm] [mm] [mm] [mm] [mm] [pcs]
Item gvz A2
N 5 x 30 Z / A2 050395 2) 050370 5 25 30 45 5 100
N 5 x 40 Z 050351 — 5 25 40 55 15 100
N 5 x 50 Z 050352 — 5 25 50 65 25 100
N 6 x 40 Z A2 — 050372 6 30 40 55 10 50
N 6 x 40 Z 050354 — 6 30 40 55 10 100
N 6 x 60 Z 050355 — 6 30 60 75 30 100
N 6 x 60 Z A2 — 050373 6 30 60 75 30 50
N 6 x 80 Z 050353 — 6 30 80 95 50 100
N 8 x 60 Z 050356 — 8 40 60 75 20 100
N 8 x 60 Z A2 — 050374 8 40 60 75 20 50
N 8 x 80 Z 050358 — 8 40 80 95 40 100
N 8 x 80 Z A2 — 050375 8 40 80 95 40 50
N 8 x 100 Z 050357 — 8 40 100 115 60 100
N 8 x 100 Z A2 — 050376 8 40 100 115 60 50
N 8 x 120 Z 050359 — 8 40 120 135 80 100
N 10 x 100 Z 050346 1) — 10 50 100 115 50 50
N 10 x 135 Z 050347 1) — 10 50 135 150 85 50

3 N 10 x 160 Z
N 10 x 230 Z
050348 1)
050335 1)


10
10
50
50
160
230
175
245
110
180
50
50
1) not pre-assembled
2) also specially suitable for fischer Pipe clips FC, see chapter Electrical fixings.

TECHNICAL DATA
N-FZ▪-▪with▪flat▪edge▪and▪nail▪and▪crossdrive▪
recess▪Z▪(N▪5▪x▪30▪FZ)

N-FZ▪-▪with▪flat▪edge▪and▪nail▪and▪crossdrive▪
recess▪Z▪(N▪6▪x▪40▪FZ)

zinc-plated stainless Drill hole Effect. Anchor Min. drill-hole depth Max. fixture Sales
Items to order only steel steel A2 diameter anchoring length for through fixings thickness unit
depth
do hef l h2 t fix
Art.-No. Art.-No. [mm] [mm] [mm] [mm] [mm] [pcs]
Item gvz A2
N 5 x 30 FZ 050338 — 5 25 30 45 5 100
N 6 x 30 FZ 050341 — 6 27 30 45 0,5 200
N 6 x 40 FZ A2 — 050369 6 30 40 55 7 50
N 6 x 40 FZ 048795 — 6 30 40 55 7 100
N 8 x 40 FZ 015903 — 8 40 40 55 0,5 50

18
N Hammerfix

TECHNICAL DATA
Hammerfix▪N-FN▪with▪flat▪edge▪ N-M▪-▪with▪zinc-plated▪nail▪and▪

Frame fixings / Stand-off installation


and▪plastic▪nail,▪pre-assembled connection▪thread▪M▪6▪/▪M▪8

Hammerfix▪N-ZZ▪-▪with▪cylinder▪
Hammerfix▪N-D A2▪with▪isolating▪
head▪and▪nail▪and▪crossdrive▪
washer▪and▪nail,▪pre-assembled
recess▪Z,▪pre-assembled

Drill hole Effect. anchoring Anchor Max. fixture Min. drill-hole Washer Sales
Items to order only diameter depth length thickness depth for through unit
fixings
do hef l t fix h2
Item Art.-No. [mm] [mm] [mm] [mm] [mm] [Ø mm] [pcs]
N 6 x 40 FN 050342 6 30 40 7 55 — 50
N 6 x 40 M6 050398 6 30 40 10 55 — 50
N 6 x 40 D A2 050367 6 30 40 10 55 19 50
N 6 x 60 D A2 050368 6 30 60 30 75 19 50
N 6 x 40 ZZ 050394 6 30 40 7 55 — 50
N 8 x 57 M8 503401 8 45 57 12 67 — 50

LOADS
Hammerfix N
Highest▪recommended▪loads1)▪for▪a▪single▪anchor.
The▪given▪loads▪are▪valid▪for▪screw▪nails▪with▪the▪specified▪diameter.
Type N5 N6 3) N8 N10

Screw nail diameter


Recommended loads in the respective base material Frec2)
Ø [mm] 3,5 4 5 7 3
Concrete ≥ C12/15 [kN] 0,16 0,20 0,27 0,33
Solid brick ≥ Mz12 [kN] 0,14 0,17 0,24 0,30
Solid sand-lime brick ≥ KS12 [kN] 0,14 0,17 0,24 0,33
Pumice solid brick ≥ V4 [kN] 0,30 0,11 0,13 0,16
Aerated concrete ≥ G2 [kN] 0,03 0,04 0,07 0,10
Aerated concrete ≥ G4 [kN] 0,07 0,09 0,11 0,16
1)
Includes the safety factor 4. 3)
The values have to be reduced by 50% for N 6 x 40 FN.
2)
Valid for tensile load, shear load and oblique load under any angle.

19
F-S Window frame fixing
The nylon fixing for stress-free stand-off installation of window
and door frames
Frame fixings / Stand-off installation

Window frames

BUILDING MATERIALS CHARACTERISTICS


▪▪ Concrete
▪▪ Vertically▪perforated▪brick
▪▪ Hollow▪block▪made▪from▪lightweight▪
concrete
▪▪ Perforated▪sand-lime▪brick
▪▪ Solid▪sand-lime▪brick
▪▪ Aerated▪concrete
▪▪ Solid▪block▪made▪from▪lightweight▪
concrete
▪▪ Solid▪brick

ADVANTAGES APPLICATIONS FUNCTIONING


▪▪ The▪ operating▪ principle▪ of▪ the▪ plug▪ ▪▪ Window▪frames ▪▪ The▪ F-S▪ is▪ suitable▪ for▪ push-through▪
3 prevents▪ the▪ frame▪ from▪ being▪ pulled▪
against▪ the▪ substrate,▪ and▪ ensures▪ a▪
▪▪ Door▪frames installation.
▪▪ By▪ tightening▪ the▪ screw,▪ the▪ glass-
stress-free,▪ long-lasting▪ fixing▪ of▪ the▪ fibre-reinforced▪ plastic▪ cone▪ is▪ drawn▪
frame. into▪ the▪ sleeve▪ which▪ gets▪ ▪ expanded▪
▪▪ It▪is▪the▪▪special▪plug▪geometry▪which▪ and▪ wedged▪ inside▪ the▪ drill▪ hole.▪ The▪
anchors▪ the▪ metal▪ and▪ plastic▪ profiles▪ window▪ frames▪ are▪ then▪ fixed▪ in▪ a▪
against▪compressive▪and▪tensile▪loads,▪ stress-free▪manner.
and▪ provides▪ a▪ secure▪ hold▪ of▪ the▪ ▪▪ The▪ maximum▪ installation▪ torque▪ is▪
window▪frame. 3 Nm▪for▪F8S▪and▪6 Nm▪for▪F10S.
▪▪ The▪ cover▪ caps▪ (available▪ separately)▪
can▪ be▪ used▪ to▪ discreetly▪ cover▪ the▪
screw▪heads.

CHARACTERISTICS

20
F-S Window frame fixing

TECHNICAL DATA

Frame fixings / Stand-off installation


F-S▪-▪with▪zinc-plated▪countersunk▪screw▪and▪
cross-drive▪recess▪Z▪3

Drill hole diameter Effect. anchoring Anchor Max. fixture Min. drill-hole Max. installation Sales
Items to order only depth length thickness depth for through torque unit
fixings
do hef l t fix h2 Tinst
Item Art.-No. [mm] [mm] [mm] [mm] [mm] [Nm] [pcs]
F 8 S 100 088635 8 40 100 50 115 3 50
F 8 S 120 088636 8 40 120 70 135 3 50
F 8 S 140 088637 8 40 140 90 155 3 50
F 10 S 75 088625 10 50 75 15 90 6 50
F 10 S 100 088626 10 50 100 40 115 6 50
F 10 S 120 088627 10 50 120 60 135 6 50
F 10 S 140 088628 10 50 140 80 155 6 50
F 10 S 165 088629 10 50 165 105 180 6 50

ACCESSORIES

Cover▪caps▪for
F-S▪Cross▪recess▪Z▪countersunk▪screws

Item to order only


Diameter Colour Sales
unit
3
D
Item Art.-No. [mm] [pcs]
ADF 12W white 060275 12 white 100

LOADS
Window frame fixing F-S
Highest▪recommended▪loads1)▪for▪a▪single▪anchor▪for▪multiple▪use▪for▪non-structural▪applications.
Type F8S F 10 S

Recommended loads in the respective base material Frec2)


Concrete ≥ C20/25 [kN] 0,78 1,48
Solid brick ≥ Mz 12 [kN] 0,90 1,25
Solid sand-lime brick ≥ KS 12 [kN] 0,90 1,25
Solid brick of lightweight aggregate concrete ≥V2 [kN] 0,25 -
Perforated sand-lime brick ≥ KSL 6 [kN] 0,25 -
1)
Includes the safety factor 4. 2)
Valid for tensile load, shear load and oblique load under any angle.

21
F-M Window frame fixing
The fixing for stress-free installation of window and door
frames with high fire resistance
Frame fixings / Stand-off installation

Fire protection doors

BUILDING MATERIALS CHARACTERISTICS


▪▪ Concrete
▪▪ Vertically▪perforated▪brick
▪▪ Hollow▪block▪made▪from▪lightweight▪
concrete
▪▪ Perforated▪sand-lime▪brick
▪▪ Solid▪sand-lime▪brick
▪▪ Aerated▪concrete
▪▪ Solid▪block▪made▪from▪lightweight▪
concrete
▪▪ Solid▪brick

ADVANTAGES APPLICATIONS FUNCTIONING


▪▪ The▪F-M▪metal▪frame▪plug▪achieves▪fire▪ ▪▪ Window▪frames ▪▪ The▪ F-M▪ is▪ suitable▪ for▪ push-through▪
3 resistance▪F 120.▪This▪allows▪for▪use▪in▪
areas▪where▪fire▪resistance▪is▪relevant.
▪▪ Door▪frames installation.
▪▪ By▪ tightening▪ the▪ screw,▪ the▪ cone▪ is▪
▪▪ The▪ operating▪ principle▪ prevents▪ the▪ drawn▪into▪the▪sleeve▪and▪the▪fixing▪is▪
window▪ frame▪ from▪ being▪ pulled▪ expanded▪ which▪ wedges▪ it▪ inside▪ the▪
against▪ the▪ substrate,▪ and▪ ensures▪ a▪ drill▪hole.▪The▪window▪frames▪are▪thus▪
stress-free▪and▪long-lasting▪fixing▪of▪the▪ fixed▪in▪a▪stress-free▪manner.
frame. ▪▪ The▪ maximum▪ installation▪ torque▪ is▪
▪▪ The▪ special▪ plug▪ geometry▪ anchors▪ 5 Nm.
the▪ metal▪ and▪ plastic▪ profiles▪ against▪
compressive▪ and▪ tensile▪ loads,▪ and▪
allows▪for▪a▪secure▪hold▪of▪the▪window▪
frame.
▪▪ The▪ cover▪ caps▪ (available▪ separately)▪
can▪ be▪ used▪ to▪ discreetly▪ cover▪ the▪
screw▪heads.

INSTALLATION

22
F-M Window frame fixing

TECHNICAL DATA
F 8 M▪-▪with▪flat▪mushroom▪screw▪

Frame fixings / Stand-off installation


head▪and▪crossdrive▪recess▪Z▪2

F 10 M▪-▪with▪countersunk▪screw▪and▪
crossdrive▪recess▪Z▪3

Drill hole Min. drill-hole depth Effect. anchoring Anchor Max. fixture Drive Sales
Items to order only diameter for through fixings depth length thickness unit
do h2 hef l t fix
Item Art.-No. [mm] [mm] [mm] [mm] [mm] [pcs]
F 8 M 72 088660 1) 8 90 30 72 42 PH2 100
F 8 M 92 088662 1) 8 110 30 92 62 PH2 100
F 8 M 112 088664 1) 8 130 30 112 82 PH2 100
F 8 M 132 088666 1) 8 150 30 132 102 PH2 100
F 10 M 72 088670 2) 10 90 30 72 42 PH3 100
F 10 M 92 088672 2) 10 110 30 92 62 PH3 100
F 10 M 112 088674 2) 10 130 30 112 82 PH3 100
F 10 M 132 088676 2) 10 150 30 132 102 PH3 100
F 10 M 152 088678 2) 10 170 30 152 122 PH3 100
F 10 M 182 088680 2) 10 200 30 182 152 PH3 50
F 10 M 202 061064 2) 10 220 30 202 172 PH3 50
1) Screw head Ø 9 mm
2) Screw head Ø 13 mm

ACCESSORIES
3
Cover▪cap▪ADM 10

Items to order only Colour Cap height Cap Fits Sales unit

Item Art.-No. [mm] [Ø mm] [pcs]


ADM 10 W 088688 white 4 15 F 10M 100
ASM 10 W 060320 white — 16 F 10M 100

LOADS
Metal frame fixing F-M
Highest▪recommended▪loads1)▪for▪a▪single▪anchor▪for▪multiple▪use▪for▪non-structural▪applications.
Type F 10 M

Recommended loads in the respective base material Frec2)


Concrete ≥ C20/25 [kN] 1,38
Solid brick ≥ Mz 12 [kN] 1,28
Solid sand-lime brick ≥ KS 12 [kN] 1,28
Solid brick of lightweight aggregate ≥V2 [kN] 0,48
Perforated sand-lime brick ≥ KSL 6 [kN] 0,55
1)
Includes the safety factor 4. 2)
Valid for tensile load, shear load and oblique load under any angle.

23
FFSZ / FFS Window frame fixing

The economical special screw for window installation


Frame fixings / Stand-off installation

Window frames

BUILDING MATERIALS
▪▪ Concrete
▪▪ Vertically▪perforated▪brick
▪▪ Hollow▪block▪made▪from▪lightweight▪
concrete
▪▪ Perforated▪sand-lime▪brick
▪▪ Solid▪sand-lime▪brick
▪▪ Aerated▪concrete
▪▪ Solid▪block▪made▪from▪lightweight▪
concrete
▪▪ Solid▪brick

ADVANTAGES APPLICATIONS FUNCTIONING


▪▪ No▪ additional▪ plugs▪ are▪ required▪ for▪ ▪▪ Window▪frames ▪▪ Please▪note▪the▪drill▪hole▪and▪screw-in▪
3 screw▪installation▪so▪work▪can▪▪progress▪
quickly▪and▪economically.
▪▪ Door▪frames
▪▪ Squared▪timbers
depths▪ for▪ different▪ building▪ materials▪
as▪listed▪in▪the▪table.
▪▪ The▪ small▪ 6▪ mm▪ drill▪ bit▪ diameter▪ is▪▪ ▪▪ In▪ order▪ to▪ avoid▪ the▪ screw▪ twisting▪
particularly▪ efficient▪ when▪ used▪ for▪ during▪ installation▪ in▪ concrete,▪ the▪
series▪installations. maximum▪anchorage▪depths▪stipulated▪
▪▪ The▪ continuous▪ thread▪ prevents▪ the▪ must▪be▪adhered▪to.
window▪ frame▪ from▪ being▪ pulled▪ ▪▪ Cylinder-head▪screws▪are▪
against▪ the▪ substrate▪ and▪ ensures▪ a▪ recommended▪for▪recessed▪installation▪
stress-free,▪ long-lasting▪ fixing▪ of▪ the▪ in▪wooden▪profiles.
frame. ▪▪ Flat-head▪screws▪are▪recommended▪for▪
▪▪ The▪special▪thread▪reduces▪the▪amount▪ installation▪ in▪ plastic▪ and▪ aluminium▪
of▪force▪required▪when▪screwing▪in.▪This▪ profiles.
means▪that▪the▪installation▪process▪can▪
be▪ completed▪ without▪ the▪ use▪ of▪ too▪
much▪force.

INSTALLATION

24
FFSZ / FFS Window frame fixing

TECHNICAL DATA

Frame fixings / Stand-off installation


Frame▪fixing▪screw▪FFSZ▪-▪with▪cylinder▪head

Drill hole diameter Screw length Drive Head Sales unit


Items to order only
do ls
Item Art.-No. [mm] [mm] [Ø mm] [pcs]
FFSZ 7,5 x 52 T25 092695 6 52 T25 7,5 100
FFSZ 7,5 x 62 T25 092697 6 62 T25 7,5 100
FFSZ 7,5 x 72 T25 092698 6 72 T25 7,5 100
FFSZ 7,5 x 82 T25 092699 6 82 T25 7,5 100
FFSZ 7,5 x 92 T25 092700 6 92 T25 7,5 100
FFSZ 7,5 x 102 T25 092701 6 102 T25 7,5 100
FFSZ 7,5 x 112 T25 092702 6 112 T25 7,5 100
FFSZ 7,5 x 122 T25 092703 6 122 T25 7,5 100
FFSZ 7,5 x 132 T25 092704 6 132 T25 7,5 100
FFSZ 7,5 x 152 T25 092705 6 152 T25 7,5 100
FFSZ 7,5 x 182 T25 092706 6 182 T25 7,5 100
FFSZ 7,5 x 202 T25 092708 6 202 T25 7,5 100
FFSZ 7,5 x 212 T25 092709 6 212 T25 7,5 100

TECHNICAL DATA
Frame▪fixing▪screw▪FFS▪-▪with▪flat▪head

Drill hole diameter Screw length Drive Head Sales


Items to order only unit
do ls
Item Art.-No. [mm] [mm] [Ø mm] [pcs]
FFS 7,5 x 42 062379 6 42 T30 11,5 100
FFS 7,5 x 52 062395 6 52 T30 11,5 100
FFS 7,5 x 62
FFS 7,5 x 72
062396
061550
6
6
62
72
T30
T30
11,5
11,5
100
100 3
FFS 7,5 x 82 068955 6 82 T30 11,5 100
FFS 7,5 x 92 061551 6 92 T30 11,5 100
FFS 7,5 x 102 068956 6 102 T30 11,5 100
FFS 7,5 x 112 061552 6 112 T30 11,5 100
FFS 7,5 x 122 068957 6 122 T30 11,5 100
FFS 7,5 x 132 061553 6 132 T30 11,5 100
FFS 7,5 x 152 061554 6 152 T30 11,5 100
FFS 7,5 x 182 061555 6 182 T30 11,5 100
FFS 7,5 x 202 068958 6 202 T30 11,5 100
FFS 7,5 x 212 061556 6 212 T30 11,5 100

ACCESSORIES
Cover▪cap▪FFS A

Cap Cap height Fits Sales unit


Art.-No. [Ø mm] [mm] [pcs]
FFS A-BR dark brown 061561 15 4 FFS-flat head 100
FFS A-W white 061560 15 4 FFS-flat head 100

LOADS
Frame fixing screw FFSZ and FFS
Highest▪recommended▪loads1)▪for▪a▪single▪anchor▪for▪multiple▪use▪for▪non-structural▪applications▪in▪concrete▪C20/25.
Cracked or Non-cracked concrete
Type Effective anchorage depth Recommended tensile load Recommended shear load Min. spacing Min. edge distance

hef Nrec Vrec smin cmin


[mm] [kN] [kN] [mm] [mm]
FFS 7,5 20 0,9 0,4 60 30
FFSZ 7,5 20 0,9 0,4 60 30
FFS 7,5 40 1,9 0,6 120 30
FFSZ 7,5 40 1,9 0,6 120 30
1)
Required safety factors are considered.

25
Thermax 8/10 Stand-off installation
The thermally separated stand-off installation in external
thermal insulation composite systems (ETICS)
Frame fixings / Stand-off installation

External lighting Signs and down pipes

BUILDING MATERIALS
▪▪ Concrete
▪▪ Vertically▪perforated▪brick
▪▪ Hollow▪block▪made▪from▪lightweight▪
concrete
▪▪ Perforated▪sand-lime▪brick
▪▪ Solid▪sand-lime▪brick
▪▪ Building▪brick
▪▪ Aerated▪concrete

ADVANTAGES APPLICATIONS FUNCTIONING


▪▪ The▪ stand-off▪ installation▪ allows▪ for▪ For the thermally separated fixing of: ▪▪ The▪ Thermax▪ 8▪ and▪ 10▪ systems▪ are▪
the▪fixture▪to▪be▪adjusted▪to▪the▪exact▪ ▪▪ Signs suitable▪for▪pre-positioned▪installation.
position▪ required,▪ reducing▪ pressure▪ ▪▪ Lighting ▪▪ The▪ self▪ drilling,▪ glass-fibre-reinforced▪
marks▪ and▪ damage▪ to▪ the▪ ETICS.▪▪ ▪▪ Letter▪boxes cone▪ cuts▪ its▪ own▪ way▪ through▪ the▪
3 Combining▪ Thermax▪ 8▪ and▪ 10▪ with▪ ▪▪ Motion▪detectors plaster▪ or▪ render▪ into▪ the▪ insulation▪
the▪universal▪plug▪UX▪provides▪a▪secure▪ ▪▪ Downpipes during▪installation.
anchoring▪in▪the▪substrate. ▪▪ Lightning▪rods ▪▪ The▪self▪drilling▪cone▪acts▪as▪a▪thermal▪
▪▪ The▪ plastic▪ cone▪ creates▪ a▪ thermal▪ ▪▪ Blind▪guide▪rails barrier▪to▪minimise▪heat▪loss.
barrier▪ between▪ the▪ fixture▪ and▪ the▪ ▪▪ Simple▪installation▪without▪the▪need▪of▪
substrate▪ which▪ makes▪ an▪ energy▪ special▪tools.
efficient▪▪fixing. ▪▪ The▪ extensive▪ range▪ features▪ fitting▪
▪▪ The▪glass▪fibre▪reinforced▪plastic▪cone▪ options▪with▪chipboard▪screws▪(4.5mm▪
cuts▪ its▪ own▪ way▪ through▪ the▪ ETICS▪ -▪6 mm)▪self▪tapping▪screws▪(6.3 mm)▪
with▪a▪positive▪fit▪and▪allows▪for▪simple▪ and▪metric▪screws▪(M6/M8/M10).
and▪fast▪installations▪without▪the▪need▪
for▪any▪special▪tools.

26
Thermax 8/10 Stand-off installation

TECHNICAL DATA

Frame fixings / Stand-off installation


Thermax▪8▪and▪10

Drill hole Drill hole Usable Anchorage Cover Width across Chipboard / metric / Sales
Items to order only diameter depth length depth cap-Ø nut sheet metal screw unit
do h0 tfix hef  SW
Item Art.-No. [mm] [mm] [mm] [mm] [mm] [mm]   [pcs]
Thermax 8/60 M6 045685 1) 10 120 45 - 60 60 18 10 4,5 - 6,0 / M6 / 6,3 20
Thermax 8/80 M6 045686 1) 10 140 60 - 80 60 18 10 4,5 - 6,0 / M6 / 6,3 20
Thermax 8/100 M6 045687 1) 10 160 80 - 100 60 18 10 4,5 - 6,0 / M6 / 6,3 20
Thermax 8/120 M6 045688 1) 10 180 100 - 120 60 18 10 4,5 - 6,0 / M6 / 6,3 20
Thermax 8/140 M6 045689 1) 10 200 120 - 140 60 18 10 4,5 - 6,0 / M6 / 6,3 20
Thermax 8/160 M6 045690 1) 10 220 140 - 160 60 18 10 4,5 - 6,0 / M6 / 6,3 20
Thermax 8/180 M6 045691 1) 10 240 160 - 180 60 18 10 4,5 - 6,0 / M6 / 6,3 20
Thermax 10/100 M6 045692 1) 12 160 80 - 100 70 22 13 4,5 - 6,0 / M6 / 6,3 20
Thermax 10/120 M6 045693 1) 12 180 100 - 120 70 22 13 4,5 - 6,0 / M6 / 6,3 20
Thermax 10/140 M6 045694 1) 12 200 120 - 140 70 22 13 4,5 - 6,0 / M6 / 6,3 20
Thermax 10/160 M6 045695 1) 12 220 140 - 160 70 22 13 4,5 - 6,0 / M6 / 6,3 20
Thermax 10/180 M6 045696 1) 12 240 160 - 180 70 22 13 4,5 - 6,0 / M6 / 6,3 20
Thermax 10/200 M6 512605 12 260 180 - 200 70 22 13 4,5 - 6,0 / M6 / 6,3 20
Thermax 10/220 M6 514250 12 280 200 - 220 70 22 13 4,5 - 6,0 / M6 / 6,3 20
Thermax 10/240 M6 514251 12 300 220 - 240 70 22 13 4,5 - 6,0 / M6 / 6,3 20
Thermax 10/100 M8 045697 12 160 80 - 100 70 22 13 M8 20
Thermax 10/120 M8 045698 12 180 100 - 120 70 22 13 M8 20
Thermax 10/140 M8 045699
Thermax 10/160 M8 045700
12
12
200
220
120 - 140
140 - 160
70
70
22
22
13
13
M8
M8
20
20 3
Thermax 10/180 M8 514252 12 240 160 - 180 70 22 13 M8 20
Thermax 10/200 M8 514253 12 260 180 - 200 70 22 13 M8 20
Thermax 10/220 M8 514254 12 280 200 - 220 70 22 13 M8 20
Thermax 10/240 M8 514255 12 300 220 - 240 70 22 13 M8 20
Thermax 10/100 M10 045702 12 160 80 - 100 70 22 13 M10 20
Thermax 10/120 M10 045703 12 180 100 - 120 70 22 13 M10 20
Thermax 10/140 M10 045704 12 200 120 - 140 70 22 13 M10 20
Thermax 10/160 M10 045705 12 220 140 - 160 70 22 13 M10 20
Thermax 10/180 M10 514256 12 240 160 - 180 70 22 13 M10 20
Thermax 10/200 M10 514257 12 260 180 - 200 70 22 13 M10 20
Thermax 10/220 M10 514258 12 280 200 - 220 70 22 13 M10 20
Thermax 10/240 M10 514259 12 300 220 - 240 70 22 13 M10 20
Thermax 10/100 M10 512172 2) 12 160 80 - 100 70 22 13 M10 20
Thermax 10/120 M10 512173 2) 12 180 100 - 120 70 22 13 M10 20
Thermax 10/160 M10 512174 2) 12 220 140 - 160 70 22 13 M10 20
Thermax 10/180 M10 517165 2) 12 240 160 - 180 70 22 13 M10 20
1) including SX 5 2) bagged items / 2 per pack

27
Thermax 8/10 Stand-off installation

LOADS
Stand-off installation Thermax 8 and 10
Frame fixings / Stand-off installation

Highest▪recommended▪tensile▪loads1)▪for▪a▪single▪anchor.
Type UX10/Thermax 8 UX12/Thermax 10
Recommended tensile loads in the respective base material Nrec2)
Concrete 3) 4) ≥ C20/25 [kN] 1,00 1,00
Solid brick 3) 4) ≥ Mz 12 [kN] 0,50 0,70
Perforated sand-lime brick 3) 4) ≥ KSL 12 [kN] 0,60 0,80
Vertically perforated brick 4) ≥ Hlz 12 [kN] 0,20 0,30
Aerated concrete 3) 4) ≥P4 [kN] 0,40 0,60
1)
Includes the safety factor 7. 3)
The given recommended tensile loads apply for fastenings with metric screws. When using
2)
The UX-plug must be installed in the base material with full anchorage depth. The drilling method chipboard screws with diameter 6,0 mm they have to be reduced to 0,35 kN.
is to be adapted to the building material used. As different joint qualities are possible, the given 4)
The given recommended tensile loads apply for fastenings with metric screws. When using a
values only apply for installation in the brick. SX 5-plug chipboard screws with diameter 4,5 - 5,5 mm they have to be reduced to 0,1 kN.

LOADS
Stand-off installation Thermax 8 and 10
Highest▪recommended▪shear▪loads1)▪for▪a▪single▪anchor.
Type UX10/Thermax 8 UX12/Thermax 10

Recommended shear loads Vrec1)


External Thermal Insulation Composite System2) ≤ 180 mm [kN] 0,15 0,20
1)
Required safety factors are considered. 2)
Values are valid for an EWI made from PS- respectively PU-rigid foam panels.

ADDITIONAL SIZES AVAILABLE

Thermax 12/16 Stand-off installation


3 The approved stand-off installation with thermal barrier in external thermal
insulation composite systems (ETICS)

Awnings Satellite dishes and air conditioning units

BUILDING MATERIALS APPLICATIONS


Approved for: For the thermally separated fixing of:
▪▪ Concrete,▪cracked▪and▪non-cracked ▪▪ Awnings
▪▪ Vertically▪perforated▪brick ▪▪ Canopies
▪▪ Hollow▪block▪made▪from▪lightweight▪ ▪▪ French▪balcony▪railings
concrete ▪▪ Brackets
▪▪ Perforated▪sand-lime▪brick ▪▪ Air▪conditioning▪units
▪▪ Solid▪sand-lime▪brick ▪▪ Satellite▪dishes
▪▪ Solid▪brick
Also suitable for:
▪▪ Aerated▪concrete

For more Information on this product range please contact the Technical Services Department on 01491 827 920

28
VBS-M Remedial wall tie

The quick façade repair for two-leaf cavity walls

Frame fixings / Stand-off installation


Facing masonry

VERSIONS APPROVALS
▪▪ zinc-plated▪steel
▪▪ stainless▪steel

BUILDING MATERIALS
▪▪ Facing▪masonry▪with▪and▪without▪an▪
air▪layer
 
 
 

ADVANTAGES APPLICATIONS FUNCTIONING


▪▪ The▪ approved▪ fixing▪ in▪ stone▪ and▪ in▪ ▪▪ VBS-M▪ is▪ especially▪ suitable▪ for▪ ▪▪ The▪ remedial▪ wall▪ tie▪ VBS-M▪ is▪ set▪
joints▪ from▪ at▪ least▪ 50▪ mm▪ facing▪ applications▪ where▪ external▪ thermal▪ in▪ the▪ load-bearing▪ layer▪ and▪ into▪
masonry▪ provides▪ a▪ high▪ degree▪ of▪
flexibility▪and▪security.
insulation▪ composite▪ systems▪ (ETICS)▪
are▪installed▪past▪to▪the▪façade▪repair.
facing▪ masonry▪ using▪ push-through▪
installation.
3
▪▪ Use▪in▪joints▪and▪with▪a▪low▪anchorage▪ ▪▪ Retrospective▪repairs▪of▪two-leaf▪cavity▪ ▪▪ In▪ accordance▪ with▪ the▪ approval,▪ no▪
depth▪of▪just▪50▪ mm▪allows▪for▪a▪quick▪ walls▪in▪line▪with▪DIN▪1053-1▪and▪EN▪ drill▪hole▪cleaning▪is▪required.
and▪economical▪installation. 845/846▪as▪well▪as▪economy▪facings▪ ▪▪ The▪ two▪ expansion▪ zones▪ in▪ the▪ load-
▪▪ The▪small▪anchor▪rim▪and▪screw▪head▪ with▪DIN▪18515. bearing▪layer▪and▪in▪the▪facing▪masonry▪
allow▪ for▪ a▪ surface-flush▪ or▪ deep-set▪ ensure▪a▪secure▪fixation.
installation. ▪▪ The▪ plug▪ doesn‘t▪ fix▪ into▪ the▪ facing▪
▪▪ The▪ drill▪ hole▪ can▪ be▪ retrospectively▪ masonry▪ until▪ the▪ head▪ grips▪ into▪ the▪
sealed▪so▪that▪it▪is▪no▪longer▪visible▪in▪ load-bearing▪ layer.▪ This▪ ensures▪ the▪
the▪façade. very▪best▪installation▪safety.
▪▪ A▪ drip▪ coil▪ prevents▪ condensate▪
running▪ into▪ the▪ load-bearing▪ layer,▪
thus▪ preventing▪ frost▪ and▪ corrosive▪
damage.

INSTALLATION

29
VBS-M Remedial wall tie

TECHNICAL DATA
Frame fixings / Stand-off installation

Remedial▪wall▪tie▪VBS-M

zinc-plated stainless Max. shell distance at Max. shell distance Facing Drill Drill hole Effect. Anchor Sales
steel steel 115 mm facing masonry, at 115 mm facing masonry + cavity diameter depth anchoring length unit
Items to order only
flush installation masonry, 20 mm depth
sunk installation
tfix d0 h0 hef l
Art.-No. Art.-No. [mm] [mm] [mm] [mm] [mm] [mm] [mm] [pcs]
Item gvz A4
VBS-M 8 x 120 514243 1) — 20* — 70 8 140 50 120 100
VBS-M 8 x 120 — 514236 20 — 70 8 140 50 120 100
VBS-M 8 x 185 514244 1) 514237 20 40 135 8 205 50 185 100
VBS-M 8 x 205 514245 1) — 40 40 155 8 225 50 205 100
VBS-M 8 x 205 — 514238 40 60 155 8 225 50 205 100
VBS-M 8 x 225 514246 1) — 60 80 175 8 245 50 225 100
VBS-M 8 x 225 — 514239 40 60 175 8 245 50 225 100
VBS-M 8 x 245 514247 1) — 60 100 195 8 265 50 245 100
VBS-M 8 x 245 — 514240 80 100 195 8 265 50 245 100
VBS-M 8 x 265 514248 1) — 100 120 215 8 285 50 265 100
VBS-M 8 x 265 — 514241 100 100 215 8 285 50 265 100
VBS-M 8 x 285 514249 1) — 100 140 235 8 305 50 285 100
VBS-M 8 x 285 — 514242 120 140 235 8 305 50 285 100
* Max. 20 mm mortar layer in the case of 50 mm thick economy facing.
The drill hole depth is to be adapted accordingly in the case of sunk installation of the anchor.

3 1) Please call for availability and delivery times.

ACCESSORIES / DRILLS

▪SDS▪Plus▪IV▪8/100/400 ▪Masonry▪drill▪bit▪8/100/400
▪SDS▪Plus▪II▪Pointer▪8/400/460

Items to order only Description Sales unit


Item Art.-No. [pcs]
SDS PLUS IV 8/100/400 517689 fischer Quattric drill bit with SDS fixture and short flute for drilling in concrete 1
fischer masonry drill bit with SDS fixture and short flute, ground sharp, for rotary
Masonry drill bit 8/100/400 517690 1
drilling in perforated brick and in the bed joint
SDS Plus II 8/400/460 503936 fischer hammer drill bit for drilling in concrete and in the facing brick 1

ACCESSORIES / BITS

FPB▪TX▪15/5▪long Star▪recess▪TX

Items to order only Description Sales unit


Item Art.-No. [pcs]
fischer Profi-Bit long, which can be extended to 50 mm bit, allows for deep setting in stone and in
FPB TX 15/5 long 517693 5
the bed joint
FPB TX25/10 507728 fischer Profi-Bit 10

30
Decisive factors

Technical disclaimer / Decisive factors


Due▪ to▪ the▪ complexity▪ of▪ building▪ materials,▪ tools,▪ fixing▪ elements▪ and▪ installation▪

Frame fixings / Stand-off installation


techniques▪ a▪ comprehensive▪ recommendation▪ depends▪ on▪ full▪ and▪ detailed▪
understanding▪of▪specific▪site▪conditions.▪

This▪ document▪ is▪ a▪ factual▪ record▪ of▪ anchor▪ performance▪ obtained▪ under▪ specific▪
conditions▪and▪does▪not▪constitute▪an▪endorsement▪of▪the▪suitability▪of▪the▪product▪for▪
any▪specific▪application.▪This▪responsibility▪remains▪with▪the▪customer.
The▪data▪given▪shall▪be▪▪used▪as▪a▪guide▪for▪assessment▪or▪anchor▪suitability.▪Even▪when▪
our▪advice▪is▪given▪in▪good▪faith▪it▪cannot▪be▪binding▪for▪this▪reason▪and▪we▪cannot▪accept▪
any▪liability▪for▪any▪anchor▪failure▪due▪to▪the▪wrong▪design,▪misuse▪or▪wrong▪installation.

For▪safety▪critical▪applications▪only▪anchors▪with▪an▪ETA▪or▪Zulassung▪German▪Approval▪
shall▪be▪used.

For further product information please contact the fischer Technical Department:
Phone:▪▪01491▪827▪920
E-mail:▪▪technical@fischer.co.uk

fischer fixings (UK) Ltd.


Whitely▪Road,▪Wallingford,▪Oxon,▪OX10▪9AT.

We▪cannot▪be▪responsible▪for▪any▪errors,▪and▪we▪reserve▪the▪right▪to▪make▪technical▪and▪
range▪modifications▪without▪notice.
No▪liability▪is▪accepted▪for▪printing▪errors▪and▪omissions.

General Notice
The▪information▪in▪this▪brochure▪is▪intended▪for▪general▪guidance▪only▪and▪is▪given▪
without▪engagement.▪Additional▪information▪and▪advice▪on▪specific▪applications▪is▪
available▪from▪our▪Technical▪Support▪Team.▪For▪this▪however,▪we▪require▪a▪precise▪
description▪of▪your▪particular▪application.

All▪the▪data▪in▪this▪brochure▪concerning▪work▪with▪our▪fixings▪must▪be▪adapted▪to▪
suit▪local▪conditions▪and▪the▪type▪of▪materials▪in▪use.

If▪no▪detailed▪performance▪specifications▪are▪given▪for▪certain▪articles▪and▪types,▪
please▪contact▪our▪Technical▪Service▪Department▪for▪advice.

Phone:▪▪01491▪827▪920
E-mail:▪▪technical@fischer.co.uk

31
01/2013

Frame fixings & Stand-off installation / 3 of 12 Product sections / 01/2013 · (V1) · Printed in the UK
Contacts

fischer fixings UK Ltd.


Whitely Road
Oxon OX10 9AT Wallingford
Great Britain
Phone (0044) 1491 827900
Fax (0044) 1491 827953
E-mail info@fischer.co.uk
www.fischer.co.uk

Technical Service
If you need any assistance, simply contact your local fischer
representative. For more specialised application problems
please contact our Technical Services Team.

Your dealer:
fischer fixings UK Ltd. Wallingford, Oxon, OX10 9AT.

Phone 01491 827 920


e-mail: technical@fischer.co.uk

Technical Training
We also offer training seminars
suited to your individual needs and
requirements.
Please call the number above to find
out more

www.fischer.co.uk

Vous aimerez peut-être aussi