Académique Documents
Professionnel Documents
Culture Documents
▪▪ SXR▪frame▪fixing 3
▪▪ FUR▪universal▪frame▪fixing 9
▪▪ SXS▪frame▪fixing 14
fixings / Stand-off
▪▪ N▪hammerfix 17
▪▪ F-S▪window▪frame▪fixing 20
▪▪ F-M▪metal▪window▪frame▪fixing 22
▪▪ FFSZ▪/▪FFS▪window▪from▪screws 24
▪▪ Thermax▪8/10▪Stand-off▪installation▪ 26
Frame fixings
▪▪ VBS-M▪remedial▪wall▪tie 29
Frame
3
3
2
SXR Frame fixing
The all-round solution with European Technical Approval (ETA)
for solid and hollow building materials
VERSIONS APPROVALS
▪▪ Zinc-plated▪steel
▪▪ Stainless▪steel
BUILDING MATERIALS
Approved for:
▪▪ Concrete▪≥▪C12/15
▪▪ Vertically▪perforated▪brick
▪▪ Hollow▪ blocks▪ made▪ from▪ lightweight▪
concrete
▪▪ Perforated▪sand-lime▪brick
▪▪ Solid▪sand-lime▪brick
▪▪ Aerated▪concrete
▪▪ Solid▪ block▪ made▪ from▪ lightweight▪ and▪
normal▪weight▪concrete
3
▪▪ Solid▪brick
▪▪ Thermal▪insulation▪blocks
Also suitable for:
▪▪ Natural▪stone▪with▪dense▪structure
▪▪ Solid▪panel▪made▪from▪gypsum
INSTALLATION
3
SXR Frame fixing
TECHNICAL DATA
Frame fixings / Stand-off installation
SXR-T▪-▪with▪fischer▪safety▪screw
zinc-plated stainless hot-dip Drill hole Min. drill Min. Anchor Max. fixture Drive Sales
steel steel galvanised diameter hole depth embedment length thickness unit
Approval
Items to order only
steel for through depth
fixings
do h2 hnom (hv) l t fix
Art.-No. Art.-No. Art.-No. DIBt ETA [mm] [mm] [mm] [mm] [mm] [pcs]
Item gvz A4 fvz
SXR 8 x 60 T 502999 — — ▯ ■ 8 70 50 60 10 T30 50
SXR 8 x 80 T 503000 — — ▯ ■ 8 90 50 80 30 T30 50
SXR 8 x 100 T 503001 — — ▯ ■ 8 110 50 100 50 T30 50
SXR 8 x 120 T 503002 — — ▯ ■ 8 130 50 120 70 T30 50
SXR 10 x 80 T 046263 046272 — ▯ ■ 10 90 50 80 30 TX40 50
SXR 10 x 100 T 046264 046274 — ▯ ■ 10 110 50 100 50 TX40 50
SXR 10 x 100 T — — 509534 — — 10 110 50 100 50 TX40 50
SXR 10 x 120 T 046265 046278 — ▯ ■ 10 130 50 120 70 TX40 50
SXR 10 x 120 T — — 509535 — — 10 130 50 120 70 TX40 50
SXR 10 x 140 T 046266 046279 — ▯ ■ 10 150 50 140 90 TX40 50
SXR 10 x 140 T — — 509536 — — 10 150 50 140 90 TX40 50
SXR 10 x 160 T 046267 046283 — ▯ ■ 10 170 50 160 110 TX40 50
SXR 10 x 180 T 046268 046285 — ▯ ■ 10 190 50 180 130 TX40 50
SXR 10 x 200 T 046269 046286 — ▯ ■ 10 210 50 200 150 TX40 50
3 SXR 10 x 230 T
SXR 10 x 260 T
046270
046271
046287
046288 1)
—
—
▯
▯
■
■
10
10
240
270
50
50
230
260
180
210
TX40
TX40
50
50
1) delivery on request
TECHNICAL DATA
SXR▪-▪without▪screw
SXR-Z▪-▪with▪zinc-plated▪fischer▪safety▪screw▪
for▪Cross▪drive▪PZ-bit
Drill hole Min. drill-hole Min. embedment Anchor Max. fixture Drive Sales
Items to order only diameter depth for through depth length thickness unit
fixings
do h2 hnom (hv) l t fix
Item Art.-No. [mm] [mm] [mm] [mm] [mm] [pcs]
SXR 6 x 35 503228 6 45 30 35 5 — 100
SXR 6 x 50 503229 6 60 30 50 20 — 100
SXR 6 x 60 503230 6 70 30 60 30 — 100
SXR 8 x 60 506194 8 70 50 60 10 — 100
SXR 8 x 80 506196 8 90 50 80 30 — 100
SXR 8 x 100 506198 8 110 50 100 50 — 100
SXR 8 x 120 506199 8 130 50 120 70 — 100
SXR 6 x 35 Z 503231 1) 6 45 30 35 5 PZ2 50
SXR 6 x 50 Z 503232 1) 6 60 30 50 20 PZ2 50
SXR 6 x 60 Z 503233 1) 6 70 30 60 30 PZ2 50
1) not pre-assembled
4
SXR Frame fixing
TECHNICAL DATA
Drill hole Min. drill-hole Effect. Anchor Max. fixture Screw Drive Sales
Items to order only Approval diameter depth for through anchoring depth length thickness unit
fixings
do h2 hnom (hv) l t fix
Item Art.-No. ETA [mm] [mm] [mm] [mm] [mm] [pcs]
SXR 6 x 60 Z 503233 6 70 30 60 30 - PZ2 50
SXR 8 x 60 Z 505261 8 70 50 60 10 - PZ3 50
SXR 8 x 80 Z 505262 8 90 50 60 30 - PZ3 50
SXR 8 x 100 Z 505263 8 110 50 100 50 - PZ3 50
SXR 8 x 120 Z 505264 8 130 50 120 70 PZ3 50
SXR 10 x 80 Z 47977 ■ 10 90 50 80 30 7 x 87 PZ4 50
SXR 10 x 100 Z 47978 ■ 10 110 50 100 50 7 x 107 PZ4 50
SXR 10 x 120 Z 47979 ■ 10 130 50 120 70 7 x 127 PZ4 50
SXR 10 x 140 Z 47980 ■ 10 150 50 140 90 7 x 147 PZ4 50
SXR 10 x 160 Z 47981 ■ 10 170 50 160 110 7 x 167 PZ4 50
1) not pre-assembled
TECHNICAL DATA
3
SXR-FUS▪-▪with▪fischer▪hexagon▪safety▪
screw,▪moulded-on▪washer▪and▪integrated▪
bit▪T40
zinc-plated stainless Hot-dip Drill hole Min. drill- Min. Anchor Max. fixture Drive Sales unit
steel steel galvanised diameter hole depth embedment length thickness
Approval
5
SXR Frame fixing
ACCESSORIES
Frame fixings / Stand-off installation
Cover▪cap▪ADT
Items to order only Colour Cap Fits safety screw with seat ITX-Star recess Sales unit
[Ø mm] [pcs]
Item Art.-No.
ADT 15 W 060326 white 15 40 100
ADT 15 DB 060329 dark brown 15 40 100
ADT 18 W 060334 white 18 40 100
ADT 18 DB 060337 dark brown 18 40 100
Washer▪U
stainless▪steel▪A2
ACCESSORIES
Aircrete▪hole▪
punch▪GBS
LOADS
Frame fixing SXR 4)
Highest▪permissible▪loads1)▪for▪a▪single▪anchor▪for▪multiple▪fixings▪of▪non-structural▪applications▪in▪normal▪concrete▪≥▪C12/15▪resp.▪≥▪
B15.▪For▪the▪design▪the▪complete▪approval▪ETA-07/0121▪has▪to▪be▪considered.
6
SXR Frame fixing
LOADS
Frame fixing SXR 4)
1)
The required safety factors as regulated in the approval are considered. 5)
The given values apply for rotary drilling (without impact) in perforated bricks and
2)
Minimum permissible spacing without reducing the permissible load. In certain cases aerated concrete.
the spacing within pairs of anchors may be reduced up to 100 mm while reducing the 6)
Minimum permissible edge distance with surcharge as well as to not solidified joints.
permissible load. For edge distance without surcharge see approval.
3)
Valid for tensile load, shear load and oblique load under any angle. Restrictions for 7)
Valid for raw density higher than 1,0 kg/dm³. Otherwise the permissible load has to
permanently acting tensile loads see approval. For combinations of tensile loads, be determined by tests on site.
shear loads, bending moments see approval table 4. 8)
Drill hole created by punching.
4)
gvz and A4. For exterior applications of galvanised screws measures against incoming
humidity have to be taken.
7
SXR Frame fixing
LOADS
Frame fixing SXR 4)
Frame fixings / Stand-off installation
Highest▪permissible▪loads1)▪for▪a▪single▪anchor▪for▪multiple▪fixings▪of▪non-structural▪applications▪in▪masonry.
For▪the▪design▪the▪complete▪approval▪ETA-07/0121▪has▪to▪be▪considered.
Solid brick masonry and perforated brick masonry
Type Compressive Brick type, Min. Min. Permissible Min. Min. edge
brick strength naming acc. DIN embedment depth substrate thickness load spacing distance
fb hnom (hv) hmin Fperm3) 5) 6) smin2) cmin2)
[N/mm²] [-] [mm] [mm] [kN] [mm] [mm]
Solid brick Mz
SXR 8 ≥ 20 Mz 50 100 0,70 100 100
SXR10 ≥ 20 Mz 50 100 1,29 100 100
Solid sand-lime brick and solid block KS
SXR 8 ≥ 10 KS 50 100 0,70 100 100
SXR10 ≥ 10 KS 50 100 1,29 100 100
Vertically perforated brick Hlz
SXR 8 ≥6 HLz 50 100 0,34 100 100
SXR10 ≥6 HLz 50 100 0,57 100 100
Perforated sand-lime brick KSL
SXR 8 ≥ 12 KSL 50 100 0,57 100 100
SXR10 ≥ 12 KSL 50 100 0,70 100 100
Hollow block of lightweight aggregate concrete Hbl
SXR 8 ≥ 10 Hbl 50 100 0,70 100 100
SXR10 ≥ 10 Hbl 50 100 0,70 100 100
Solid brick and solid block of lightweight aggregate concrete V
SXR 8 ≥2 V 50 100 0,70 100 100
SXR10 ≥2 V 50 100 0,85 100 100
Aerated concrete block PB2/ PP2
SXR10 ≥2 PP2/PB2/P2,2 50 100 0,157) 200 100
Aerated concrete block ≥ PB4/PP4
3 SXR10
1)
≥ 3/ ≥ 4,4 PP3/PB3/P4,4
The required partial safety factors for material resistance as well as a partial safety factor for
50
5)
100 0,26 200 100
The given values apply for rotary drilling (without impact). The given loads are reference values
load actions of γL = 1,4 are considered. which may change due to type of brick and manufacturer.
2)
Minimum possible axial spacing (anchor group) while reducing the permissible load. 6)
Valid for temperatures in the substrate up to +50°C (resp. short term up to 80°C). For long term
3)
Valid for tensile load, shear load and oblique load under any angle. For combinations of tensile temperatures up to 30°C higher permissible loads may be possible.
loads, shear loads and bending moments see approval. 7)
Drill hole created by punching.
4)
gvz and A4. For exterior applications of galvanised screws measures against incoming humidity
have to be taken.
LOADS
Frame fixing SXR
Highest▪recommended▪loads1)▪for▪a▪single▪anchor.
The▪given▪loads▪are▪valid▪for▪wood▪screws▪with▪the▪specified▪diameter.
Type SXR 6
8
FUR Universal frame fixing
The user-friendly problem solver for a large range of building
materials
VERSIONS APPROVALS
▪▪ Zinc-plated▪steel
▪▪ Stainless▪steel
BUILDING MATERIALS
Approved for:
▪▪ Concrete▪≥▪C12/15
▪▪ Three-layer▪composite▪exterior▪wall▪
panels
▪▪ Lightweight▪aggregate▪concrete
▪▪ Vertically▪perforated▪brick
▪▪ Hollow▪block▪made▪from▪lightweight▪
concrete
▪▪ Perforated▪sand-lime▪brick
▪▪ Solid▪sand-lime▪brick
▪▪ Solid▪block▪made▪from▪lightweight▪
concrete
3
▪▪ Solid▪brick
Also suitable for:
▪▪ Natural▪stone▪with▪dense▪structure
▪▪ Solid▪panel▪made▪from▪gypsum
INSTALLATION
9
FUR Universal frame fixing
TECHNICAL DATA
Frame fixings / Stand-off installation
FUR-T▪-▪safety▪screw▪with▪countersunk▪head
zinc-plated stainless Drill hole Min. drill-hole depth for Min. embedment Anchor Max. fixture Drive Sales
Approval
Items to order only steel steel diameter through fixings depth length thickness unit
TECHNICAL DATA
zinc-plated stainless Drill hole Min. drill-hole depth for Min. embedment Anchor Max. fixture Width Sales
Approval
Items to order only steel steel diameter through fixings depth length thickness across nut unit
10
FUR Universal frame fixing
TECHNICAL DATA
zinc-plated stainless Drill hole Min. drill-hole depth Min. embedment Anchor Max. fixture Width Sales
Approval
Items to order only steel steel diameter for through fixings depth length thickness across nut unit
ACCESSORIES
3
Cover▪cap▪ADT
Items to order only Colour Cap Fits safety screw with seat ITX-Star recess Sales unit
[Ø mm] [pcs]
Item Art.-No.
ADT 15 W 060326 white 15 40 100
ADT 15 DB 060329 dark brown 15 40 100
ADT 18 W 060334 white 18 40 100
ADT 18 DB 060337 dark brown 18 40 100
11
FUR Universal frame fixing
LOADS
Universal frame fixing FUR 4)
Frame fixings / Stand-off installation
Highest▪permissible▪loads1)▪for▪a▪single▪anchor▪for▪multiple▪fixings▪of▪non-structural▪applications▪in▪normal▪concrete▪≥▪C12/15▪resp.▪≥▪
B155).▪For▪the▪design▪the▪complete▪approval▪Z-21.2-1204▪has▪to▪be▪considered.
Cracked or Non-cracked concrete
Type Min. embedment depth Min. substrate thickness Permissible load Min. spacing Min. edge distance
LOADS
Universal frame fixing FUR 4)
Highest▪permissible▪loads1)▪for▪a▪single▪anchor▪for▪multiple▪fixings▪of▪facades▪in▪masonry.
For▪the▪design▪the▪complete▪approval▪Z-21.2-1204▪has▪to▪be▪considered.
Solid brick masonry and perforated brick masonry
Type Compressive Brick type, Min. Min. Permissible load Min. Min.
brick strength naming acc. DIN embedment depth substrate thickness spacing edge distance
fb hnom (hv) h (d) Fperm3) 5) smin (a) 2) cmin (ar) 6)
[N/mm²] [-] [mm] [mm] [kN] [mm] [mm]
Solid brick Mz
FUR 8 ≥ 12 Mz 70 115 0,60 100 100
3 FUR 10
FUR 14
≥ 12
≥ 12
Mz
Mz
70
70
115
115
0,80
0,80
100
250
100
100
Solid sand-lime brick and solid block KS
FUR 8 ≥ 12 KS 70 115 0,60 100 100
FUR 10 ≥ 12 KS 70 115 0,80 100 100
FUR 14 ≥ 12 KS 70 115 0,80 250 100
Vertically perforated brick Hlz
FUR 8 ≥ 12 HLz 70 115 - 100 100
FUR 10 ≥ 12 HLz 70 115 0,37) 250 100
FUR 14 ≥ 12 HLz 70 115 0,57) 250 100
Perforated sand-lime brick KSL
FUR 8 ≥6 KSL 70 115 - 100 100
FUR 10 ≥6 KSL 70 115 0,40 250 100
FUR 14 ≥6 KSL 70 115 0,60 250 100
Hollow block of lightweight aggregate concrete Hbl
FUR 8 ≥2 Hbl 708) 115 - 100 100
FUR 10 ≥2 Hbl 708) 115 0,25 250 100
FUR 14 ≥2 Hbl 708) 115 0,30 250 100
Solid brick and solid block of lightweight aggregate concrete
FUR 8 ≥2 V 70 115 - 100 100
FUR 10 ≥2 V 70 115 0,25 100 100
FUR 14 ≥2 V 70 115 0,50 250 100
1)
The required safety factors as regulated in the approval are considered. 5)
The given values apply for rotary drilling in perforated bricks (without impact).
2)
Minimum permissible spacing without reducing the permissible load. 6)
Minimum permissible edge distance with surcharge as well as to not solidified joints. For edge
3)
Valid for tensile load, shear load and oblique load under any angle. Restrictions for permanently distance without surcharge see approval.
acting tensile loads see approval. For combinations of tensile loads, shear loads, bending 7)
Valid for raw density higher than 1,0 kg/dm³. Otherwise the permissible load has to be deter-
moments see approval table 4. mined by tests on site.
4)
gvz and A4. For exterior applications of galvanised screws measures against incoming humidity 8)
The expansion part of the plug must be located in the web of the brick (see approval, appendix 6).
have to be taken.
12
FUR Universal frame fixing
LOADS
Universal frame fixing FUR 4)
13
SXS frame fixing
The high-performance frame fixing for solid building materials
and cracked concrete
Frame fixings / Stand-off installation
VERSIONS APPROVALS
▪▪ Zinc-plated▪steel
▪▪ Stainless▪steel
BUILDING MATERIALS
Approved for:
▪▪ Concrete▪C20/25▪to▪C50/60
▪▪ Three-layer▪ composite▪ exterior▪ wall▪
panels
▪▪ Hollow▪ block▪ made▪ from▪ lightweight▪
concrete
▪▪ Solid▪sand-lime▪brick
▪▪ Aerated▪concrete
▪▪ Solid▪brick
Also suitable for:
3 ▪▪ Natural▪stone▪with▪dense▪structure
▪▪ Solid▪ block▪ made▪ from▪ lightweight▪
concrete
▪▪ Solid▪panel▪made▪from▪gypsum
▪▪ Concrete▪C12/15
INSTALLATION
14
SXS frame fixing
TECHNICAL DATA
zinc-plated stainless Drill hole Min. embedment Anchor length Max. fixture Min. drill hole Drive Sales
Approval
Items to order only
steel steel diameter depth thickness depth unit
do hnom (hv) l t fix td
Art.-No. Art.-No. DIBt ETA [mm] [mm] [mm] [mm] [mm] [pcs]
Item gvz A4
SXS 10 x 80 T 019601 019602 ▯ ■ 10 50 80 30 90 T40 50
SXS 10 x 100 T 019604 019605 ▯ ■ 10 50 100 50 110 T40 50
SXS 10 x 120 T 019616 019617 ▯ ■ 10 50 120 70 130 T40 50
SXS 10 x 140 T 019621 019623 ▯ ■ 10 50 140 90 150 T40 50
SXS 10 x 160 T 024076 024077 ▯ ■ 10 50 160 110 170 T40 50
SXS 10 x 180 T 024080 024082 ▯ ■ 10 50 180 130 190 T40 50
TECHNICAL DATA
SXS-F US▪with▪CO-NA▪hexagon-head▪screw▪
with▪integrated▪washer
3
zinc-plated stainless Drill hole Min. embedment Anchor Max. fixture Min. drill hole Width across Sales
Approval
ACCESSORIES
Cover▪cap▪ADT
Items to order only Colour Cap Seat ITX-Star recess Sales unit
Item Art.-No. [Ø mm] [pcs]
ADT 15 W 060326 white 15 TX40 100
ADT 15 DB 060329 dark brown 15 TX40 100
ADT 18 W 060334 white 18 TX40 100
ADT 18 DB 060337 dark brown 18 TX40 100
15
SXS frame fixing
ACCESSORIES
Frame fixings / Stand-off installation
Washer▪U▪stainless▪steel▪A2
LOADS
Frame fixing SXS 4)
Highest▪permissible▪loads1)▪for▪a▪single▪anchor▪in▪normal▪concrete▪≥▪C20/25▪resp.▪≥▪B25.
For▪the▪design▪the▪complete▪approval▪Z-21.2-1734▪has▪to▪be▪considered.
Cracked concrete Non-cracked concrete
3 Type Min. embed-
ment depth
Min.
substrate
Permissible Permissible Min. spacing Min. edge
tensile load shear load distance
Permissible Permissible Min. spacing Min. edge
tensile load shear load distance
thickness
hnom (hv) hmin Nperm6) Vperm6) smin2) cmin2) Nperm6) Vperm6) smin2) cmin2)
[mm] [mm] [kN] [kN] [mm] [mm] [kN] [kN] [mm] [mm]
SXS 10 50 100 1,0 2,5 55 50 1,3 2,5 55 60
1)
The required partial safety factors for material resistance as well as a partial safety factor for 3)
For combinations of tensile loads, shear loads, bending moments as well as reduced edge
load actions of γL = 1,4 are considered. distances or spacings (anchor groups) see approval.
2)
Minimum possible axial spacings resp. edge distance (anchor group) while reducing the permissi- 4)
gvz and A4. For exterior applications of galvanised screws measures against incoming humidity
ble load. The combination of the given min. spacing and min. edge distance is not possible. One have to be taken.
of them has to be increased according approval. 6)
Valid for temperatures in the substrate up to +50°C (resp. short term up to 80°C). For long term
temperatures up to 30°C higher permissible loads may be possible.
LOADS
Frame fixing SXS 4)
Highest▪permissible▪loads1)▪for▪a▪single▪anchor▪for▪multiple▪fixings▪of▪facades▪in▪masonry.
For▪the▪design▪the▪complete▪approval▪Z-21.2-1695▪has▪to▪be▪considered.
Solid brick masonry and perforated brick masonry
Type Compressive Brick type, Min. Min. Permissible Min. Min.
brick strength naming acc. DIN embedment depth substrate thickness load spacing edge distance
fb hnom (hv) h (d) Fperm3) 5) smin (a)2) cmin (ar)6)
[N/mm²] [-] [mm] [mm] [kN] [mm] [mm]
Solid brick Mz
SXS10 ≥ 12 Mz 50 15,3 0,8 (0,60)9) 100 100
Solid sand-lime brick and solid block KS
SXS10 ≥ 12 KS 50 15,3 0,8 (0,60)9) 100 100
Hollow block of lightweight aggregate concrete Hbl
SXS10 ≥2 Hbl 508) 15,3 0,25 250 100
Solid brick and solid block of lightweight aggregate concrete V
SXS10 ≥2 V 50 15,3 0,25 100 100
1)
The required safety factors as regulated in the approval are considered. 5)
The given values apply for rotary drilling in perforated bricks (without impact).
2)
Minimum permissible spacing without reducing the permissible load. 6)
Minimum permissible edge distance with surcharge as well as to not solidified joints. For edge
3)
Valid for tensile load, shear load and oblique load under any angle. Restrictions for permanently distance without surcharge see approval.
acting tensile loads see approval. For combinations of tensile loads, shear loads, bending 8)
The expansion part of the plug must be located in the web of the brick (see approval, appendix 6).
moments see approval table 4. 9)
The higher values apply to solid bricks without handling pocket.
4)
gvz and A4. For exterior applications of galvanised screws measures against incoming humidity
have to be taken.
16
N Hammerfix
The hammer-in plug for a simple, fast and economical
installation
VERSIONS CHARACTERISTICS
▪▪ Zinc-plated▪steel
▪▪ Stainless▪steel
BUILDING MATERIALS
▪▪ Concrete
▪▪ Solid▪sand-lime▪brick
▪▪ Building▪brick
▪▪ Natural▪stone
▪▪ Solid▪block▪made▪from▪lightweight▪
concrete
INSTALLATION
17
N Hammerfix
TECHNICAL DATA
Frame fixings / Stand-off installation
Hammerfix▪N-Z▪with▪nail,▪pre-assembled
Hammerfix▪N-Z-A2▪with▪stainless▪steel▪A2▪
nail,▪pre-assembled
zinc-plated stainless Drill hole Effect. Anchor Min. drill-hole Max. fixture Sales
Items to order only steel steel A2 diameter anchoring depth length depth for through thickness unit
fixings
do hef l h2 t fix
Art.-No. Art.-No. [mm] [mm] [mm] [mm] [mm] [pcs]
Item gvz A2
N 5 x 30 Z / A2 050395 2) 050370 5 25 30 45 5 100
N 5 x 40 Z 050351 — 5 25 40 55 15 100
N 5 x 50 Z 050352 — 5 25 50 65 25 100
N 6 x 40 Z A2 — 050372 6 30 40 55 10 50
N 6 x 40 Z 050354 — 6 30 40 55 10 100
N 6 x 60 Z 050355 — 6 30 60 75 30 100
N 6 x 60 Z A2 — 050373 6 30 60 75 30 50
N 6 x 80 Z 050353 — 6 30 80 95 50 100
N 8 x 60 Z 050356 — 8 40 60 75 20 100
N 8 x 60 Z A2 — 050374 8 40 60 75 20 50
N 8 x 80 Z 050358 — 8 40 80 95 40 100
N 8 x 80 Z A2 — 050375 8 40 80 95 40 50
N 8 x 100 Z 050357 — 8 40 100 115 60 100
N 8 x 100 Z A2 — 050376 8 40 100 115 60 50
N 8 x 120 Z 050359 — 8 40 120 135 80 100
N 10 x 100 Z 050346 1) — 10 50 100 115 50 50
N 10 x 135 Z 050347 1) — 10 50 135 150 85 50
3 N 10 x 160 Z
N 10 x 230 Z
050348 1)
050335 1)
—
—
10
10
50
50
160
230
175
245
110
180
50
50
1) not pre-assembled
2) also specially suitable for fischer Pipe clips FC, see chapter Electrical fixings.
TECHNICAL DATA
N-FZ▪-▪with▪flat▪edge▪and▪nail▪and▪crossdrive▪
recess▪Z▪(N▪5▪x▪30▪FZ)
N-FZ▪-▪with▪flat▪edge▪and▪nail▪and▪crossdrive▪
recess▪Z▪(N▪6▪x▪40▪FZ)
zinc-plated stainless Drill hole Effect. Anchor Min. drill-hole depth Max. fixture Sales
Items to order only steel steel A2 diameter anchoring length for through fixings thickness unit
depth
do hef l h2 t fix
Art.-No. Art.-No. [mm] [mm] [mm] [mm] [mm] [pcs]
Item gvz A2
N 5 x 30 FZ 050338 — 5 25 30 45 5 100
N 6 x 30 FZ 050341 — 6 27 30 45 0,5 200
N 6 x 40 FZ A2 — 050369 6 30 40 55 7 50
N 6 x 40 FZ 048795 — 6 30 40 55 7 100
N 8 x 40 FZ 015903 — 8 40 40 55 0,5 50
18
N Hammerfix
TECHNICAL DATA
Hammerfix▪N-FN▪with▪flat▪edge▪ N-M▪-▪with▪zinc-plated▪nail▪and▪
Hammerfix▪N-ZZ▪-▪with▪cylinder▪
Hammerfix▪N-D A2▪with▪isolating▪
head▪and▪nail▪and▪crossdrive▪
washer▪and▪nail,▪pre-assembled
recess▪Z,▪pre-assembled
Drill hole Effect. anchoring Anchor Max. fixture Min. drill-hole Washer Sales
Items to order only diameter depth length thickness depth for through unit
fixings
do hef l t fix h2
Item Art.-No. [mm] [mm] [mm] [mm] [mm] [Ø mm] [pcs]
N 6 x 40 FN 050342 6 30 40 7 55 — 50
N 6 x 40 M6 050398 6 30 40 10 55 — 50
N 6 x 40 D A2 050367 6 30 40 10 55 19 50
N 6 x 60 D A2 050368 6 30 60 30 75 19 50
N 6 x 40 ZZ 050394 6 30 40 7 55 — 50
N 8 x 57 M8 503401 8 45 57 12 67 — 50
LOADS
Hammerfix N
Highest▪recommended▪loads1)▪for▪a▪single▪anchor.
The▪given▪loads▪are▪valid▪for▪screw▪nails▪with▪the▪specified▪diameter.
Type N5 N6 3) N8 N10
19
F-S Window frame fixing
The nylon fixing for stress-free stand-off installation of window
and door frames
Frame fixings / Stand-off installation
Window frames
CHARACTERISTICS
20
F-S Window frame fixing
TECHNICAL DATA
Drill hole diameter Effect. anchoring Anchor Max. fixture Min. drill-hole Max. installation Sales
Items to order only depth length thickness depth for through torque unit
fixings
do hef l t fix h2 Tinst
Item Art.-No. [mm] [mm] [mm] [mm] [mm] [Nm] [pcs]
F 8 S 100 088635 8 40 100 50 115 3 50
F 8 S 120 088636 8 40 120 70 135 3 50
F 8 S 140 088637 8 40 140 90 155 3 50
F 10 S 75 088625 10 50 75 15 90 6 50
F 10 S 100 088626 10 50 100 40 115 6 50
F 10 S 120 088627 10 50 120 60 135 6 50
F 10 S 140 088628 10 50 140 80 155 6 50
F 10 S 165 088629 10 50 165 105 180 6 50
ACCESSORIES
Cover▪caps▪for
F-S▪Cross▪recess▪Z▪countersunk▪screws
LOADS
Window frame fixing F-S
Highest▪recommended▪loads1)▪for▪a▪single▪anchor▪for▪multiple▪use▪for▪non-structural▪applications.
Type F8S F 10 S
21
F-M Window frame fixing
The fixing for stress-free installation of window and door
frames with high fire resistance
Frame fixings / Stand-off installation
INSTALLATION
22
F-M Window frame fixing
TECHNICAL DATA
F 8 M▪-▪with▪flat▪mushroom▪screw▪
F 10 M▪-▪with▪countersunk▪screw▪and▪
crossdrive▪recess▪Z▪3
Drill hole Min. drill-hole depth Effect. anchoring Anchor Max. fixture Drive Sales
Items to order only diameter for through fixings depth length thickness unit
do h2 hef l t fix
Item Art.-No. [mm] [mm] [mm] [mm] [mm] [pcs]
F 8 M 72 088660 1) 8 90 30 72 42 PH2 100
F 8 M 92 088662 1) 8 110 30 92 62 PH2 100
F 8 M 112 088664 1) 8 130 30 112 82 PH2 100
F 8 M 132 088666 1) 8 150 30 132 102 PH2 100
F 10 M 72 088670 2) 10 90 30 72 42 PH3 100
F 10 M 92 088672 2) 10 110 30 92 62 PH3 100
F 10 M 112 088674 2) 10 130 30 112 82 PH3 100
F 10 M 132 088676 2) 10 150 30 132 102 PH3 100
F 10 M 152 088678 2) 10 170 30 152 122 PH3 100
F 10 M 182 088680 2) 10 200 30 182 152 PH3 50
F 10 M 202 061064 2) 10 220 30 202 172 PH3 50
1) Screw head Ø 9 mm
2) Screw head Ø 13 mm
ACCESSORIES
3
Cover▪cap▪ADM 10
Items to order only Colour Cap height Cap Fits Sales unit
LOADS
Metal frame fixing F-M
Highest▪recommended▪loads1)▪for▪a▪single▪anchor▪for▪multiple▪use▪for▪non-structural▪applications.
Type F 10 M
23
FFSZ / FFS Window frame fixing
Window frames
BUILDING MATERIALS
▪▪ Concrete
▪▪ Vertically▪perforated▪brick
▪▪ Hollow▪block▪made▪from▪lightweight▪
concrete
▪▪ Perforated▪sand-lime▪brick
▪▪ Solid▪sand-lime▪brick
▪▪ Aerated▪concrete
▪▪ Solid▪block▪made▪from▪lightweight▪
concrete
▪▪ Solid▪brick
INSTALLATION
24
FFSZ / FFS Window frame fixing
TECHNICAL DATA
TECHNICAL DATA
Frame▪fixing▪screw▪FFS▪-▪with▪flat▪head
ACCESSORIES
Cover▪cap▪FFS A
LOADS
Frame fixing screw FFSZ and FFS
Highest▪recommended▪loads1)▪for▪a▪single▪anchor▪for▪multiple▪use▪for▪non-structural▪applications▪in▪concrete▪C20/25.
Cracked or Non-cracked concrete
Type Effective anchorage depth Recommended tensile load Recommended shear load Min. spacing Min. edge distance
25
Thermax 8/10 Stand-off installation
The thermally separated stand-off installation in external
thermal insulation composite systems (ETICS)
Frame fixings / Stand-off installation
BUILDING MATERIALS
▪▪ Concrete
▪▪ Vertically▪perforated▪brick
▪▪ Hollow▪block▪made▪from▪lightweight▪
concrete
▪▪ Perforated▪sand-lime▪brick
▪▪ Solid▪sand-lime▪brick
▪▪ Building▪brick
▪▪ Aerated▪concrete
26
Thermax 8/10 Stand-off installation
TECHNICAL DATA
Drill hole Drill hole Usable Anchorage Cover Width across Chipboard / metric / Sales
Items to order only diameter depth length depth cap-Ø nut sheet metal screw unit
do h0 tfix hef SW
Item Art.-No. [mm] [mm] [mm] [mm] [mm] [mm] [pcs]
Thermax 8/60 M6 045685 1) 10 120 45 - 60 60 18 10 4,5 - 6,0 / M6 / 6,3 20
Thermax 8/80 M6 045686 1) 10 140 60 - 80 60 18 10 4,5 - 6,0 / M6 / 6,3 20
Thermax 8/100 M6 045687 1) 10 160 80 - 100 60 18 10 4,5 - 6,0 / M6 / 6,3 20
Thermax 8/120 M6 045688 1) 10 180 100 - 120 60 18 10 4,5 - 6,0 / M6 / 6,3 20
Thermax 8/140 M6 045689 1) 10 200 120 - 140 60 18 10 4,5 - 6,0 / M6 / 6,3 20
Thermax 8/160 M6 045690 1) 10 220 140 - 160 60 18 10 4,5 - 6,0 / M6 / 6,3 20
Thermax 8/180 M6 045691 1) 10 240 160 - 180 60 18 10 4,5 - 6,0 / M6 / 6,3 20
Thermax 10/100 M6 045692 1) 12 160 80 - 100 70 22 13 4,5 - 6,0 / M6 / 6,3 20
Thermax 10/120 M6 045693 1) 12 180 100 - 120 70 22 13 4,5 - 6,0 / M6 / 6,3 20
Thermax 10/140 M6 045694 1) 12 200 120 - 140 70 22 13 4,5 - 6,0 / M6 / 6,3 20
Thermax 10/160 M6 045695 1) 12 220 140 - 160 70 22 13 4,5 - 6,0 / M6 / 6,3 20
Thermax 10/180 M6 045696 1) 12 240 160 - 180 70 22 13 4,5 - 6,0 / M6 / 6,3 20
Thermax 10/200 M6 512605 12 260 180 - 200 70 22 13 4,5 - 6,0 / M6 / 6,3 20
Thermax 10/220 M6 514250 12 280 200 - 220 70 22 13 4,5 - 6,0 / M6 / 6,3 20
Thermax 10/240 M6 514251 12 300 220 - 240 70 22 13 4,5 - 6,0 / M6 / 6,3 20
Thermax 10/100 M8 045697 12 160 80 - 100 70 22 13 M8 20
Thermax 10/120 M8 045698 12 180 100 - 120 70 22 13 M8 20
Thermax 10/140 M8 045699
Thermax 10/160 M8 045700
12
12
200
220
120 - 140
140 - 160
70
70
22
22
13
13
M8
M8
20
20 3
Thermax 10/180 M8 514252 12 240 160 - 180 70 22 13 M8 20
Thermax 10/200 M8 514253 12 260 180 - 200 70 22 13 M8 20
Thermax 10/220 M8 514254 12 280 200 - 220 70 22 13 M8 20
Thermax 10/240 M8 514255 12 300 220 - 240 70 22 13 M8 20
Thermax 10/100 M10 045702 12 160 80 - 100 70 22 13 M10 20
Thermax 10/120 M10 045703 12 180 100 - 120 70 22 13 M10 20
Thermax 10/140 M10 045704 12 200 120 - 140 70 22 13 M10 20
Thermax 10/160 M10 045705 12 220 140 - 160 70 22 13 M10 20
Thermax 10/180 M10 514256 12 240 160 - 180 70 22 13 M10 20
Thermax 10/200 M10 514257 12 260 180 - 200 70 22 13 M10 20
Thermax 10/220 M10 514258 12 280 200 - 220 70 22 13 M10 20
Thermax 10/240 M10 514259 12 300 220 - 240 70 22 13 M10 20
Thermax 10/100 M10 512172 2) 12 160 80 - 100 70 22 13 M10 20
Thermax 10/120 M10 512173 2) 12 180 100 - 120 70 22 13 M10 20
Thermax 10/160 M10 512174 2) 12 220 140 - 160 70 22 13 M10 20
Thermax 10/180 M10 517165 2) 12 240 160 - 180 70 22 13 M10 20
1) including SX 5 2) bagged items / 2 per pack
27
Thermax 8/10 Stand-off installation
LOADS
Stand-off installation Thermax 8 and 10
Frame fixings / Stand-off installation
Highest▪recommended▪tensile▪loads1)▪for▪a▪single▪anchor.
Type UX10/Thermax 8 UX12/Thermax 10
Recommended tensile loads in the respective base material Nrec2)
Concrete 3) 4) ≥ C20/25 [kN] 1,00 1,00
Solid brick 3) 4) ≥ Mz 12 [kN] 0,50 0,70
Perforated sand-lime brick 3) 4) ≥ KSL 12 [kN] 0,60 0,80
Vertically perforated brick 4) ≥ Hlz 12 [kN] 0,20 0,30
Aerated concrete 3) 4) ≥P4 [kN] 0,40 0,60
1)
Includes the safety factor 7. 3)
The given recommended tensile loads apply for fastenings with metric screws. When using
2)
The UX-plug must be installed in the base material with full anchorage depth. The drilling method chipboard screws with diameter 6,0 mm they have to be reduced to 0,35 kN.
is to be adapted to the building material used. As different joint qualities are possible, the given 4)
The given recommended tensile loads apply for fastenings with metric screws. When using a
values only apply for installation in the brick. SX 5-plug chipboard screws with diameter 4,5 - 5,5 mm they have to be reduced to 0,1 kN.
LOADS
Stand-off installation Thermax 8 and 10
Highest▪recommended▪shear▪loads1)▪for▪a▪single▪anchor.
Type UX10/Thermax 8 UX12/Thermax 10
For more Information on this product range please contact the Technical Services Department on 01491 827 920
28
VBS-M Remedial wall tie
VERSIONS APPROVALS
▪▪ zinc-plated▪steel
▪▪ stainless▪steel
BUILDING MATERIALS
▪▪ Facing▪masonry▪with▪and▪without▪an▪
air▪layer
INSTALLATION
29
VBS-M Remedial wall tie
TECHNICAL DATA
Frame fixings / Stand-off installation
Remedial▪wall▪tie▪VBS-M
zinc-plated stainless Max. shell distance at Max. shell distance Facing Drill Drill hole Effect. Anchor Sales
steel steel 115 mm facing masonry, at 115 mm facing masonry + cavity diameter depth anchoring length unit
Items to order only
flush installation masonry, 20 mm depth
sunk installation
tfix d0 h0 hef l
Art.-No. Art.-No. [mm] [mm] [mm] [mm] [mm] [mm] [mm] [pcs]
Item gvz A4
VBS-M 8 x 120 514243 1) — 20* — 70 8 140 50 120 100
VBS-M 8 x 120 — 514236 20 — 70 8 140 50 120 100
VBS-M 8 x 185 514244 1) 514237 20 40 135 8 205 50 185 100
VBS-M 8 x 205 514245 1) — 40 40 155 8 225 50 205 100
VBS-M 8 x 205 — 514238 40 60 155 8 225 50 205 100
VBS-M 8 x 225 514246 1) — 60 80 175 8 245 50 225 100
VBS-M 8 x 225 — 514239 40 60 175 8 245 50 225 100
VBS-M 8 x 245 514247 1) — 60 100 195 8 265 50 245 100
VBS-M 8 x 245 — 514240 80 100 195 8 265 50 245 100
VBS-M 8 x 265 514248 1) — 100 120 215 8 285 50 265 100
VBS-M 8 x 265 — 514241 100 100 215 8 285 50 265 100
VBS-M 8 x 285 514249 1) — 100 140 235 8 305 50 285 100
VBS-M 8 x 285 — 514242 120 140 235 8 305 50 285 100
* Max. 20 mm mortar layer in the case of 50 mm thick economy facing.
The drill hole depth is to be adapted accordingly in the case of sunk installation of the anchor.
ACCESSORIES / DRILLS
▪SDS▪Plus▪IV▪8/100/400 ▪Masonry▪drill▪bit▪8/100/400
▪SDS▪Plus▪II▪Pointer▪8/400/460
ACCESSORIES / BITS
FPB▪TX▪15/5▪long Star▪recess▪TX
30
Decisive factors
This▪ document▪ is▪ a▪ factual▪ record▪ of▪ anchor▪ performance▪ obtained▪ under▪ specific▪
conditions▪and▪does▪not▪constitute▪an▪endorsement▪of▪the▪suitability▪of▪the▪product▪for▪
any▪specific▪application.▪This▪responsibility▪remains▪with▪the▪customer.
The▪data▪given▪shall▪be▪▪used▪as▪a▪guide▪for▪assessment▪or▪anchor▪suitability.▪Even▪when▪
our▪advice▪is▪given▪in▪good▪faith▪it▪cannot▪be▪binding▪for▪this▪reason▪and▪we▪cannot▪accept▪
any▪liability▪for▪any▪anchor▪failure▪due▪to▪the▪wrong▪design,▪misuse▪or▪wrong▪installation.
For▪safety▪critical▪applications▪only▪anchors▪with▪an▪ETA▪or▪Zulassung▪German▪Approval▪
shall▪be▪used.
For further product information please contact the fischer Technical Department:
Phone:▪▪01491▪827▪920
E-mail:▪▪technical@fischer.co.uk
We▪cannot▪be▪responsible▪for▪any▪errors,▪and▪we▪reserve▪the▪right▪to▪make▪technical▪and▪
range▪modifications▪without▪notice.
No▪liability▪is▪accepted▪for▪printing▪errors▪and▪omissions.
General Notice
The▪information▪in▪this▪brochure▪is▪intended▪for▪general▪guidance▪only▪and▪is▪given▪
without▪engagement.▪Additional▪information▪and▪advice▪on▪specific▪applications▪is▪
available▪from▪our▪Technical▪Support▪Team.▪For▪this▪however,▪we▪require▪a▪precise▪
description▪of▪your▪particular▪application.
All▪the▪data▪in▪this▪brochure▪concerning▪work▪with▪our▪fixings▪must▪be▪adapted▪to▪
suit▪local▪conditions▪and▪the▪type▪of▪materials▪in▪use.
If▪no▪detailed▪performance▪specifications▪are▪given▪for▪certain▪articles▪and▪types,▪
please▪contact▪our▪Technical▪Service▪Department▪for▪advice.
Phone:▪▪01491▪827▪920
E-mail:▪▪technical@fischer.co.uk
31
01/2013
Frame fixings & Stand-off installation / 3 of 12 Product sections / 01/2013 · (V1) · Printed in the UK
Contacts
Technical Service
If you need any assistance, simply contact your local fischer
representative. For more specialised application problems
please contact our Technical Services Team.
Your dealer:
fischer fixings UK Ltd. Wallingford, Oxon, OX10 9AT.
Technical Training
We also offer training seminars
suited to your individual needs and
requirements.
Please call the number above to find
out more
www.fischer.co.uk