Included components Landscape Forms is not responsible for site preparation and footings. Refer to the
installation guide for the LEO light anchor kit for installing the anchor bolts.
CAUTION! This unit is heavy. To avoid injury or damage to the finish, we recommend using
22in 28in a crane or lift for hoisting the unit onto the anchors.
Luminaire Nut cover with 1/4‐20
x 5/8” button head
WARNING! Pole mounted luminaires must be attached either before or immediately after
cap screw
pole installation. Failure to do so may cause vibration damage to the pole and will void the
pole warranty.
Single Single
INSTALLATION PROCEDURE FOR LIGHT POLE:
Double 3/8‐16 x 1‐1/2” socket head 1. Lift the light pole into position over the installed anchors (refer to LEO anchor kit
Double
12ft 16ft 20ft 25ft cap screw with lock washer installation guide) as shown in Fig. 1. Ensure that the base plate is resting on all four
22in Clamp 28in Clamp
Pole with base plate washers.
2. Install washer, lock washer and hex nut as shown in Fig. 2.
3. Plumb and level the pole and tighten all anchors.
Shorting cap for
4. Install clamp on pole as noted in Fig. 3.
Standard For twist lock Cover plate 5. Remove access panel on luminaire arm as shown in Fig. 4. Retain screws and washers.
Twist lock receptacle, Twist lock,
Pole cap assembly (optional) 6. Using a hex key socket with extension, install luminaire to clamp as shown in Fig. 5.
optional optional
7. Connect wiring to connection terminals in the luminaire. Refer to wiring diagrams on
Tools Required pages 2 and 3.
• Safety glasses 8. Install the top cap on the pole (shipped with the pole). If the unit has a twist lock
• Wrenches, 1‐1/8” receptacle, assemble the receptacle and the top cap as shown in Fig. 8 and connect
• Screwdrivers, Phillips and straight blade wiring before installing the top cap. Install provided shorting cap or photo‐electric
• Wiring tools and connectors control.
• Proper personnel, crane or lift for hoisting unit onto anchors 9. Replace the access panel on the luminaire arm.
• Level 10. Install the nut covers as shown in Fig. 9 or the cover plate as shown in Fig. 10.
• Dimming control, if required
• Hex keys
• 5/16” hex key socket with 1‐1/2” extension. Flex drive or universal is helpful.
• Twist lock photo eye, if required
Page 1 of 3
LEO Light Date: May 19, 2017
Installation Guide www.landscapeforms.com Ph: 800.521.2546
Fig. 9 – Install nut covers
Fig. 10 – Install cover plates
Fig. 8 – Install optional twist
Fig. 7 – Install top cap
lock receptacle to top cap
Page 2 of 3
LEO Light Date: May 19, 2017
Installation Guide www.landscapeforms.com Ph: 800.521.2546
PROCEDURE FOR WIRING LEO:
The LEO light luminaire is assembled at the factory. The light cartridge is mounted into
the head of the dome and will not need to be removed during installation. The LED
cartridge is wired to the driver (located in the arm of the luminaire) at the factory. Use of
LED drivers other than the supplied unit is not recommended and will void the warranty.
The wiring schematics are to be used to connect the unit to line voltage. It is the
responsibility of the installer to make sure that all connections are made in accordance
with the NEC and local building codes. Connection hardware not included.
Line‐in wires should be connected to the terminal block as shown. Optional dimming
control is not included.
WIRING DIAGRAM: 22in luminaire, without twist lock WIRING DIAGRAM: 28in luminaire, without twist lock
Page 3 of 3