Ventilation Solutions
Product Range > Fans
Fläkt Woods experience – at your service Total air movement solutions – precisely
2 3
General ventilation Hazardous areas
The application context may vary, but Fan options for Compliance became a legal requirement We also have systems in place to
the fundamental requirements are the general ventilation Mechanical ventilation and in 2003. The Directive applies to a ensure continuous ATEX compliance
same: supply and extraction. System extraction can be required wide variety of equipment intended for during our normal production.
Units and ranges designed to provide
requirements will be dictated by building use in hazardous areas, such as petro-
size and function, and by numerous
routine ventilation and general air in environments which have chemical plants, pharmaceutical and Fan options for
movement functions for a variety of
other operational parameters, which the potentially explosive chemical manufacturing, battery rooms, ATEX environments
applications and environments include:
installed ventilation must satisfy. atmospheres – whether flourmills and grain silos. Fläkt Woods offers fully ATEX-compliant
Axial Fans
With Fläkt Woods, you have a genuinely from chemical vapours, Fläkt Woods has invested heavily in CE-marked fans in the following ranges:
comprehensive choice. We can be Bifurcated Fans fan engineering design modifications to
volatile gases or hazardous JM Aerofoil
relied on to have exactly the fan type, Box Fans achieve and satisfy the necessary high Axial fans range
model, performance, and capacity each dust. For these situations, specifications. For fans, these safety
Plate Fans Centripal EU
situation needs. You can also completely we have the widest range modifications include:
Centrifugal fans range
depend on the quality and reliability Tube Fans
of fans that comply fully with Features to avoid
of its engineering. Roof Units or minimise sparks
For introductory key details of the ATEX 100a Directive.
Centrifugal Fans Changes to the motors
Fläkt Woods fan ranges, including
Fläkt Woods also offers a and material thickness
standard features and options,
see pages 16-21. comprehensive choice of units for Impeller locking systems
whole house/domestic ventilation, as
For assistance with identifying Adjustments to impeller
well as mini air handling units for small
precisely the right fan solution tip clearances
commercial and industrial premises.
for your specific projects, visit
http://fanselector.flaktwoods.com
6 7
Fire safety
and damage limitation for the UDA & DVA High Temperature Fläkt Woods’ axial and centrifugal ranges
Roof Units General specifications are designed to give you precisely that
building fabric, immediately assurance. They offer high temperature
All these fan types are suitable for Fläkt Woods fans for smoke control
becomes the priority for the both normal and emergency smoke and fire safety are supplied with the performance that is ready to respond if
ventilation system. ventilation conditions, and can be following general specifications: the situation arises, and safe operation
inverter speed-controlled. that deserves the confidence of
Installation
designers, installers and users.
Fläkt Woods has the necessary In normal mode, they have lower –S uitable for internal
experience, and product options Specific Fan Power (SFP) values and and external mounting Emergency temperature
available, to manage such important optimised running costs, because the –R un and standby operation, capabilities
risk factors. inverter controls average power in parallel or series
While our units for emergency situations
consumption and extract rate. Standards
100 years of air movement knowledge, are suitable for normal ventilation
combined with our in-house expertise –E N 12101-3 compliant operation, they are specifically designed
Specific control functions
and contributions to the development –A erodynamic tested to for one-off operation at the following
of industry standards, mean we are well Our fan technology plays several BS ISO 5801:2007 temperatures:
placed to respond to new challenges important roles in the event of an –A coustic tested to
emergency condition. Each could BS 848-2.5:2003 200°C for 2 hours
and regulation changes.
be an important defence against – CE-marked 250°C for 2 hours
Through continuous Research,
life-threatening fumes and hot smoke:
Development and Innovation we have Motors 300°C for 2 hours
consistently advanced fan technology Control and removal of hot – IE2 motors where applicable
400°C for 2 hours
to deal with emergency fire protection. smoke/gases to give time for – IP55 rated motor protection
occupants to escape – even 100% X-rayed
Impeller
if the fan itself is subject to impeller components
–N
on-stalling pitch blade angle
high temperatures
(available on certain fans) By the nature of the process, die casting
Extraction of ‘cool’ smoke while –X
-ray examination of impeller of metals can conceal hidden porosity.
it remains unstable in the early castings This can structurally reduce core
stages of a fire strength, and increase the possibility
Pressurisation: supply of clean of fatigue or failure, especially at
air into escape routes to hold elevated emergency temperatures.
back smoke However, with Fläkt Woods’ axial fans,
Clearance: removal of residual you have the assurance that all cast
smoke after fire is contained impellers have been subjected to X-ray
and suppressed inspection to ensure test compliance
and product integrity.
Natural ventilation may be inadequate for
these needs, particularly where ‘cool’
smoke may be involved, and could be
compromised by prevailing winds.
8 9
Fire safety
• Induction Thrust
Shallow-profile centrifugal fans, ideal for car
parks with significant height restrictions,
especially those requiring a unidirectional system
for clearance of air pollution and smoke.
Fläkt Woods has the experience Products for smoke Operating on demand Tailored solutions using CFD
In a fire emergency, smoke to provide complete and precisely extraction systems In enclosed or underground
Unlike these old-style systems, with Our car park solutions are individually
is a potential killer unless tailored solutions for almost any car parks, a fire emergency
Fläkt Woods can design, supply and Fläkt Woods solutions there is no modelled to suit each building’s layout.
industrial, commercial or residential
it is quickly controlled. applications including:
install complete systems for smoke requires fast, intelligent requirement for the ventilation system to Computational Fluid Dynamics (CFD)
extraction to suit the specific needs of run continuously. Our systems operate software, combined with Fläkt Woods
It can also hamper the action to contain and control
Warehousing each individual building. Each system only when required, using a series of in-house expertise and own
work of emergency services. may comprise the appropriate the problem. Fläkt Woods strategically placed, independently fully-researched input data, is used to
Multi-storey shopping malls
Whatever the type and combination of: technology, application controlled fans. plot the ideal number, type and location
Offices of fans required for each application.
function of a building, Design knowledge, expertise and Under normal operational conditions,
Multi-occupancy housing/ sensors detect pollution such as carbon A computerised 3D model evaluates
diligent planning for the apartment blocks Mechanical or natural state of the art software
monoxide (CO), Liquefied Petroleum airflow with only the main extract system
ventilation products
fast, effective removal and special-need environments such as: combine to provide a Gas (LPG) and Nitrogen Oxides (NOx). in use. This identifies main airflow
of smoke is an essential Control systems unique approach, with Selected fans automatically induce the routes and highlights any stagnant
Enclosed or underground
Sensors contaminated air and direct it to the or recirculatory areas. Our fans are then
provision to ensure car parks tailored solutions.
main extract point for discharge. superimposed upon this model and
personnel safety. In addition to powered extract fans, Electrical wiring
placed in optimum positions to achieve
Traditional car park ventilation techniques In the event of a fire emergency, Fläkt
we offer a comprehensive range Commissioning both normal extract and emergency fire/
are based on air change rates and duct Woods systems control the direction
of ventilation components to cover smoke extract.
runs with vertical droppers and high/low of smoke travel. Smoke sensors trigger
both daily requirements and
level grilles. This ducting typically uses up fans to run up to full design speed to Main extract fans in these installations
emergency situations.
valuable headroom and parking space, direct the smoke, via other fans as can be smaller because there is less
These products are tested to necessary, to the nearest extract point. ductwork resistance. Installation costs
and such systems are costly to install
BS EN 12101 specification standards Smoke, heat and toxic fumes are are lower and, because the system
and operate. Fläkt Woods can provide
for smoke and heat control systems. removed swiftly and safely from a fire operates only when required, running
a modern alternative solution providing
benefit to client and user alike, whilst by the shortest route. costs are also minimised.
complying fully with the latest technical
requirements and European standards.
10 11
Legislation Requirements Legislation Requirements
+
“ErP” stands for “Energy related Products”. The associated Table 1
Directive supports the aims of the EU Climate and Energy Package
by encouraging the use of environmentally friendly designs (“Eco 125 W - 500 kW Efficiency Grade N
design”), in order to reduce greenhouse gas emissions by 20%, Fan Type Test Category 2013 2015
whilst also increasing the use of renewable energy sources in the
EEA (up to 20%) by 2020. However, the main focus of the ErP
directive is to increase combined fan and motor energy efficiencies
B - OPEN INLET AND DUCTED OUTLET
by 20%. This ethos is also known as the
“20-20-20” target. Although the ErP Directive only applies within ErP Compliant Product Identification ErP ErP
the EEA, others often adopt European legislation as best practice, Products that do not meet their required FMEG rating will therefore Cased Axial
especially as the Directive is based upon the Kyoto Protocol. Axial 50 58
not be ErP compliant, which in turn means that a CE mark cannot Impeller
be affixed to them. The CE Mark is a legal requirement for products
For this reason, within the main ErP Directive 2009/125/EC, to be sold within the EEA.
applicable standards have been developed for each specific
product group for use within the EEA. For fans, the Commission’s
regulation (EU) 327/2011 (also known as lot 11), applies. electric
motors and their construction are also covered separately by
Regulation 640/2009. Forward D - DUCTED INLET AND DUCTED
OUTLET
ErP ErP
Curved
Impeller
42 49
Centrifugal
For products which comply, there is a legal requirement to affix
a label which shows 5 key pieces of ErP related information, the Backward ErP ErP
FMEG grade, the measurement category, the efficiency category Curved 61 64
and the overall efficiency of the product at its optimum energy Impeller
efficiency point and if applicable, confirmation that the calculation of
fan efficiency is based on the use of an Inverter (VSD).
10 11
Energy efficiency
12 13
Energy efficiency
14 15
Range key details
Axial fans
Standard features Sizes: 315mm to 1600mm Ø Sizes: 315mm to 2800mm Ø Sizes: 500mm to 1000mm Ø Sizes: up to 3550mm Ø
All fans are certified to ISO 5801 Volume flow: up to 65m3/s Volume flow: up to 210m3/s Volume flow: up to 20m3/s Volume flow: up to 370m3/s
CE marking Static pressure: up to 2150 Pa Static pressure: up to 2070 Pa Static pressure: up to 1000 Pa Static pressure: up to 3400 Pa
X-ray inspection of all cast Operating temperature range: High temperature capability: Operating temperature: High temperature capability:
impeller parts -20°C to +50°C up to 400°C for 2 hours up to 200°C – up to 250°C for 2 hours
– options up to 400°C for 2 hours
IE2 motors where applicable IE2 motors where applicable IE2 motors where applicable IE2 motors where applicable
IE2 motors where applicable
High energy efficiency: Role: General ventilation Role: Emergency ventilation/ Motor separated from air stream
reduced SFP and/or extraction hot fire smoke extraction Role: Heavy duty industrial and
Role: Exhaust/recirculation of
infrastructure applications –
Motor protection IP55 fumes/gases/hot air
higher pressure/volume
Non-overloading
Adjustable pitch impeller for
exact performance required
Low installed noise levels
High temperature capability:
up to 200°C for 2 hours for
three-phase fans only
Range options
Long and short casings
Multiple blade configurations
Inverter: speed controllable
Explosion proof/ATEX JM Multi-stage Aerofoil JM MaXfan and SuperLight Plate Axial JM Aerofoil Plate Axial
compliant versions Sizes: 315mm to 1000mm Ø MaXfan Plus Aerofoil Sizes: 315mm to 1000mm Ø Sizes: 315mm to 710mm Ø
Higher temperature operation as standard. Larger sizes are
Sizes: 400mm to 630mm Ø Volume flow: up to 3.15m3/s
Volume flow: up to 8.8m /s 3
16 17
Range key details
Standard features
Easy to install
Quiet operation
Energy efficient: DSJ - Roof Extract Unit SuperLite Roof Unit
on demand ventilation
Sizes: 200mm to 1000mm Ø Volume flow: up to 4.3m3/s
iFan box range Volume flow: up to 6.3m3/s Static pressure: up to 540 Pa
Box fans incorporating an integral Static pressure: up to 200 Pa Operating temperature range:
intelligent control unit (ICU), plus -30°C up to +70°C
Temperature capability: up to 50°C
sensors and/or switches
Robust, fibreglass casings High efficiency axial impellers
Delivering demand control
Mounting angle up to 30° Role: General ventilation and/or
ventilation – from maximum
extraction
to trickle (20%) or stop Role: General ventilation and/or
extraction Options:
Reduces ventilation energy
Speed is 100% infinitely variable using
consumption and running costs Aerofoil Impeller
auto transformers or electrical control
Options:
– Speed controller types: Electronic,
Transformer or Inverter
Sales office UK
Fläkt Woods is a global leader in air management.
We specialize in the design and manufacture of a wide • Colchester VS
range of air climate and air movement solutions. Phone 01206 222 555
Fläkt Woods operates a policy of continuous improvement and reserves the right to supply products that may differ from
those illustrated and described in this publication. Certified dimensions can be supplied on request on receipt of order.
tel: 01206 222 555 fax: 01206 222 777 twitter: @flaktwoodsuk
email: info.uk@flaktwoods.com website: www.flaktwoods.co.uk
electronic catalogue: www.flaktwoods.com/vsecatalogue