Power Electronics

Power Electronics is the study of switching electronic circuits in order to control the flow of electrical energy. Power
Electronics is the technology behind switching power supplies, power converters, power inverters, motor drives, and
motor soft starters.

Contents
Some discrete components used in power electronics
Heatsink
Triacs
Power Electronic Converters
Soft Starters
Introduction
What is a soft starter?
Why use a soft starter?
Construction
Control
Open-Loop and Closed-Loop
Applications
High Inertia Load Characteristics
High Inertia Stall Conditions
Pump Application Load Characteristics
Pump Application Stall Conditions
Conclusion
other soft starters
References
Further reading

Some discrete components used in power electronics


Diodes

Schottky Diodes

Power Bipolar Junction Transistors

MOSFETs

Thyristors:

https://en.wikibooks.org/wiki/Power_Electronics Page 1 of 10
Power Electronics - Wikibooks, open books for an open world 04/02/18, 6*14 PM

Silicon Controlled Rectifier (SCR)

Gate Turn-Off Thyristors

Insulated Gate Bipolar Transistors (IGBT)

Gate-Commutated Thyristors

Heatsink
Motors and most other actuation devices are typically indirectly connected to the power supply through a power
transistor which acts as a switch, either allowing energy to flow from the power supply to the motor, or disconnecting
the motor from power. (The CPU, also connected to the transistor, chooses exactly when to turn it on or off).

When the switch is turned on, most of the power coming from the power supply goes to the motor. Unfortunately,
some of the power is trapped by unwanted parasitic resistance in the power transistors, heating them up. Often a
heatsink is necessary to keep the transistor from overheating and self-destructing. Practically all modern desktop or
laptop PCs require a heat sink on the CPU and on the graphics chip. (A typical robot requires a heatsink on its power
transistors, but not on its small CPU).

"Application note AN533: thermal management precautions for handling and mounting" [2] (http://www.st.com/ston
line/products/literature/an/5381.pdf) describes "how to calculate a suitable heatsink for a semiconductor device". It
looks like this applies to all power semiconductors -- FET, BJT, Triac, SRC, etc. It gives thermal resistance for DPAK
and D2PAK for FR4 alone, FR4 plus heatsink, Insulated Metallic Substrate (IMS), and IMS plus heatsink. heat sinks
sometimes.

The principles behind heatsinking these power semiconductors are the same as the principles behind PC CPU
heatsinking.

Triacs
Triacs have 3 pins. Triacs look like and are controlled much like PNP power transistors. Triacs can control AC power
in a circuit much like a relay -- it's either on (shorted) or off (open).

Turning on a triac is easy: Typically digital logic is connected so its VCC is connected to the triac A1 pin. Some digital
logic output pin is connected to a small resistor connected to the triac gate pin. When the digital logic pulls the gate
pin low (towards VDD), the triac is triggered and turns all the way on.

As long as the triac is on, the A1 and A2 pins act like they are shorted together. Current can flow in both directions
through the triac -- whether A2 is higher or lower than the A1 voltage.

Turning the triac off is a little more difficult. First the digital logic output drives the gate pin high (so it is the same
voltage as the common A1 pin). But the triac remains on until the current through the triac drops to less than the
holding current. Normally triacs are used with 50 Hz or 60 Hz AC, so the triac may stay on as long as 10 ms after the
digital logic tries to turn it off.

https://en.wikibooks.org/wiki/Power_Electronics Page 2 of 10
Power Electronics - Wikibooks, open books for an open world 04/02/18, 6*14 PM

After the triac is off, A2 acts like is disconnected and isolated from the rest of the triac (as long as the external circuit
doesn't drive it outside its voltage rating, typically plus or minus several hundred volts).

Driving a triac is very similar to driving PNP transistor -- "gate" analogous to "base", "A1" analogous to "emitter", "A2"
analogous to "collector".

By far, the most common silicon device to drive AC loads connected to mains voltage is the triac.[1] A triac works
better than a BJT or a FET transistor as a switch when controlling AC power. A triac can remain off while A2 can
swing up and down hundreds of volts (relative to A1 and the gate). It's difficult to keep a BJT or FET transistor from
spontaneously turning on in the "reverse" direction.

PNP transistors work better than triacs as switches when controlling DC power. A PNP transistor can quickly turn off
even when full current is flowing through them. A triac will stay on indefinitely when DC current flows through it.

A "snubberless triac" or "logic level triac" will not turn on with positive gate current when the A2 lead is at a negative
voltage (relative to A1), but they will turn on with a positive gate current when the A2 lead is at a positive voltage. [2]
Some "standard" triacs will turn with a positive gate current (like a power
NPN transistor) no matter if A2 is positive or negative, but such "positive
gate current triggering" is not recommended. The "negative gate current
triggering" is preferred. [3][4]

Power Electronic Converters


AC-to-DC Converter (Rectifiers)

DC-to-AC Converter (Inverter)

DC-to-DC Converter (Chopper)

AC-to-AC Converter(Cycloconverter)

Soft Starters
Soft Starters[5]
Triac

Introduction
In industrial applications, almost everything uses a motor, in fact, motors may account for up to 80% of our country’s
energy usage. There are generally three different ways to start a motor: full-voltage, reduced voltage, and inverter. A
full voltage, across-the-line, or direct on-line (DOL) start uses a contactor, which is a heavier duty three-phase relay.
Reduced voltage starting can be accomplished via several different ways: auto-transformer, wye-delta, primary
resistor/reactor, or with a solid state soft starter. Inverters are generally referred to as drives. This paper focuses on
solid state soft starters (referred to as soft starter only from here on): what they are, why they are used, their
construction, and applications.

https://en.wikibooks.org/wiki/Power_Electronics Page 3 of 10
Power Electronics - Wikibooks, open books for an open world 04/02/18, 6*14 PM

What is a soft starter?


A soft starter is a solid state motor starter that is used to start or stop a motor by notching the voltage waveform,
thereby, reducing the voltage to each phase of a motor and gradually increasing the voltage until the motor gets up to
full voltage/speed all at a fixed frequency. The profile of the increase of voltage depends on the application. The
voltage is reduced and controlled by 3 pairs of back-to-back silicon-controlled rectifiers (SCRs) (Fig. 1), which are a
type of high speed thyristor. A soft starter takes the place of a contactor and can also take the place of an overload
relay in a standard motor starting application. Fig. 1 demonstrates the configuration of a soft starter controlling a line
or wye connected motor from a three-phase source.

Figure 1: Standard Soft Starter Topology

Why use a soft starter?


In general, there are two reasons to use a soft starter: the power
distribution network may not be able to handle the inrush current of the
motor and/or the load cannot handle the high starting torque. As a rule of
thumb, a motor utilizes around 600-800% of its full load current (FLA) to
start. This current is referred to as inrush current or locked-rotor current.
Some systems, when the power is switched on, briefly pull 50 times the
normal operating current.[6] If a large motor is on a smaller power
distribution network or on a generator system, this inrush current can
internal details of a triac
cause the system voltage to dip or to “brown out.” Brown outs can cause
problems with whatever else is connected to the system, such as
computers, lights, motors, and other loads. Another problem is that the system may not even be able to start the
motor because it cannot source or supply enough current. Most industrial businesses run during the day can be fined
or charged extra (Peak Demand charges) during this peak usage time for large transients caused by large horsepower
(HP) motor start ups. These Peak Demand charges can add up very quickly, especially if the motor needs to be started
multiple times during any given day. The inrush current can be controlled one of two ways with a soft starter: either
with a current limit (discussed later) or reduced linearly with the reduced voltage, and follows this approximation:

Applications such as conveyors may not be able to handle a sudden jolt of torque from an across-the-line start.
Utilizing soft starters reduces the wear and tear on belts, conveyors, gears, chains, and gearboxes by reducing the
torque from the motor. The torque decreases as a square of the reduced voltage, and follows this approximation:

Since soft starters are generally controlled and monitored by a microprocessor, a soft starter can add many features
and protections fairly easily. It can offer a choice of the starting time, limited speed control, and energy savings. Power
monitoring, such as three-phase current, three-phase voltage, power, power usage, power factor, and motor thermal
capacity usage, can be implemented with current transformers, a voltage meter, and an internal clock. With the above
implementations, protection, for the motor or the soft starter, from the items listed below (Table 1) can also be offered
by stopping the firing of the SCRs, dropping out the bypass contactor (a contactor that carries the motor load after the
motor is up-to-speed), and/or alerting a user via some form of communications with the microprocessor and another
computer.

Possible protections that can be offered by a soft starter

https://en.wikibooks.org/wiki/Power_Electronics Page 4 of 10
Power Electronics - Wikibooks, open books for an open world 04/02/18, 6*14 PM

SCR Open Gate


Phase Unbalance
Power Loss
Undervoltage
Overtemperature
Jam
Underload
Phase Reversal
Overload
Overvoltage
Stall
Excessive Starts/Hr
Line Loss
Ground Fault
Bypass Failure

Construction
Generally, a soft starter is constructed with three pairs of SCRs reverse parallel connected to allow the current to flow
to or from the motor. Soft starters can be made by controlling just one or two phases, but this paper will focus on the
most prevalent implementation, three-phase control. Each phase of a soft starter can be controlled with an SCR pair
reverse parallel connected (Fig. 2), an SCR/diode pair reverse parallel connected (Fig. 3), or a triac (Fig. 4), depending
on cost and/or quality. The most prevalent switch in industry is probably the SCR pair and will also be the focus of
this paper. Soft starters are used almost exclusively for starting and stopping and not during the run time because of
the heat loss through the SCRs from the voltage drop across them.

Figure 2: SCR Pair

Figure 3: SCR/Diode Pair

Figure 4: Triac

A standard assembly of a soft starter uses one SCR pair per phase and once the voltage gets to within approximately
1.1V of full voltage (depending on the voltage drop across the SCR) a bypass contactor (internal or external to the soft
starter), running parallel to the SCR pairs, pulls in (Fig. 5). Once pulled in the SCRs stop firing. Typically, the bypass
contactor is much smaller than compared to what is needed for a full voltage start as the contacts only need to be able
to handle the full load current of the motor. Since the mechanical contacts cannot handle the inrush current, the SCRs
must be sized correctly to handle the motor’s locked-rotor current.

Figure 5: Standard Soft Starter Topology With Bypass

The transition from SCRs to bypass should also be near full speed to minimize the jump in current (Fig. 6). Fig. 7
shows a transition at slow speed; the transition has a jump in current near the locked-rotor or starting current,
defeating the purpose of a soft starter.

Figure 6: Near Full Speed Transition [7]

https://en.wikibooks.org/wiki/Power_Electronics Page 5 of 10
Power Electronics - Wikibooks, open books for an open world 04/02/18, 6*14 PM

Figure 7: Low Speed Transition [7]

Control
A soft starter reduces the voltage by “notching” the applied sinusoidal waveform, simulations of which can be seen in
Figures 8-13. A notch is a non-technical term for the zero voltage area in the middle waveform seen in Fig. 9. Fig. 9
also shows the forward firing SCR pulses in green and the reverse firing pulses in blue to notch the output voltage. Fig.
10-13 show a progression from a 90º firing angle to 30º. As the notch decreases in size, the Vrms increases along with
Irms. An initial voltage, determined by the user, is ramped up to full voltage by varying the firing angle depending on
the preset profile of the soft starter. Soft starters can be controlled via open-loop or closed-loop control.

Figure 8: Single Phase Simulation

Figure 9: Single Phase Simulation (90º Firing Angles, Voltage, and Current)

Figure 10: 90º ~ 341Vrms

Figure 11: 70º ~ 405Vrms

Figure 12: 50º ~ 452Vrms

Figure 13: 30º ~ 469Vrms

Open-Loop and Closed-Loop


An example of open loop control is the voltage ramp (Fig. 14), the voltage ramps from an initial voltage to full voltage
in a linear fashion without regards to the load. Pump start is another form of open-loop control. The pump starter’s
firing circuit ramps up the voltage with a profile that allows the speed/torque to ramp (Fig. 15) in a more efficient
manner and helps protect against water hammering, a common problem in pump applications. Fig. 14-15 also show
examples of soft stopping. Applications such as current limit (Fig. 16) use feedback from the motor or the line
current/voltage to change the firing angle of the SCRs as necessary, hence closed-loop. All control schemes listed
monitor back EMF of the motor as to not become unstable.

Figure 14: Voltage Ramp [7]

Figure 15: Pump Start [7]

Figure 16: Current Limit [7]

Applications

https://en.wikibooks.org/wiki/Power_Electronics Page 6 of 10
Power Electronics - Wikibooks, open books for an open world 04/02/18, 6*14 PM

Soft starters can be made for a reversing application by adding two extra SCR pairs that switch two phases. For
example, line phase “b” is connected to load phase “c” and vice versa. L2 (“b”) is connected to T3 (“c”) and L3 (“c”) is
connected to T2 (“b”) in Fig. 17. A delta configuration motor can also be controlled with a soft starter (Fig. 18), but it
will see more current than a line connected motor. As a way to get around the larger current switching, a soft starter
can be wired “inside the delta,” as can be seen in Fig. 19. Wiring in this configuration will allow the soft starter to
control a larger motor than even line connected by a √3 advantage. For instance, an “inside the delta” soft starter can
switch a 277A load versus a line connected soft starter needs to be able to switch 480A to control the same rated motor
load. A disadvantage of “inside the delta” is that it requires six leads coming from the motor which can be an added
expense with larger HP motors.

Figure 17: Reversing Soft Starter Topology

Figure 18: Delta Soft Starter Topology

Figure 19: "Inside the Delta" Topology

Above are some physical variations of soft starter applications. In contrast, kick starting and low speed ramps are
some other applications that can be implemented via different programming of SCR firing angles.

High Inertia Load Characteristics


Below are some calculated simulations of different applications of soft starters with high inertia loads. Table 2 holds
the properties the motor simulated. Fig. 20-21 shows a general full voltage start for comparison with a motor that has
a locked-rotor current LRA that is 600% of the FLA and a locked-rotor torque LRT or starting torque that is 180% of
the full load torque. See Appendix Fig. 35 for an explanation of the %Current & % Torque vs. Speed curves. Table 2:
Simulated Motor Motor Information Load Information Motor Type NEMA B Load Type High Inertia Rated HP 200
Load Inertia 36000 Rated Speed 1750 Load Speed 605 Frequency 60 %Load Factor 80%

1. of Poles 4 Motor Inertia 100


LRA % 600% %Inefficiency 30% LRT% 180%

Motors must be sized appropriately to have enough torque with respect to its load or the motor will not be able to
start, irregardless of starter type.

Figure 20: Full Voltage Starting [8]

Figure 21: Full Voltage Starting [8]

As you can see in Fig. 22, the starting current is reduced from 600% to roughly 400% and the initial starting torque is
set to 50%. The initial torque for this motor application cannot be any less than the load torque, or a stall condition
may occur (discussed later).

Figure 22: Soft Start Motor Starting Characteristics [8]

https://en.wikibooks.org/wiki/Power_Electronics Page 7 of 10
Power Electronics - Wikibooks, open books for an open world 04/02/18, 6*14 PM

In a current limit start (Fig. 23), the current is limited to a specified value, in this instance 450% of the FLA. The
lowest level to which the current can be limited depends on the motor torque. Again, caution needs to taken in setting
the current limit to make sure the motor torque does not dip below the load torque to avoid stall conditions.

Figure 23: Current Limit Motor Starting Characteristics [8] High Inertia Load Speed Characteristics Fig. 24-25 are for
comparison to an across-the-line start.

Figure 24: Soft Start [8]

Figure 25: Current Limit Start [8]

High Inertia Stall Conditions


A stall occurs when the motor torque cannot overtake the load torque and the motor cannot rotate. When this
happens, the motor will draw more current than the FLA to try to turn the load, again, defeating the purpose of the
soft starter. Motor stalls are possible if the motor torque dips below the load torque; for a high inertia load, the
starting load torque is quite high and stays relatively high. Fig. 26-27 show possible stall conditions (highlighted by
arrows) for a soft start or a current limit start. Fig. 26-27 and 32 may be slightly misleading because once the motor
stalls the speed will not increase.

Soft Starter Settings Starting Type Soft Start Initial Torque % 40%

Figure 26: Soft Start Stall [8] Soft Starter Settings Starting Type Current Limit Initial Current% 300%

Figure 27: Current Limit Stall [8]

Pump Application Load Characteristics


The pump application simulation uses the same motor characteristics as the previous high inertia application but is
connected to a pump. A pump load starts with almost no load torque and it increases with speed. The red line in Fig.
28 shows the load torque. Motor Information Load Information Motor Type NEMA B Load Type Pump Rated HP 200
Load Inertia 36000 Rated Speed 1500 Load Speed 605 Frequency 60 %Load Factor 80%

1. of Poles 4 Motor Inertia 100


LRA % 600% %Inefficiency 30% LRT% 180%

The closer the motor torque can get to the pumps torque with out dipping below it, the more potential for energy
savings. With almost no starting load torque a soft start can be set much lower than in a high inertia load. Fig. 28 is set
to 2% of locked-rotor torque.

Figure 28: Pump Soft Start [8]

Using a current limit start with this application, the motor torque is kept closer to the load torque (highlighted by
arrows) than with the soft start above (highlighted by arrows), allowing even more energy savings. Fig. 29 is set to
225% of the locked-rotor torque.

Figure 29: Pump Current Limit [8]

https://en.wikibooks.org/wiki/Power_Electronics Page 8 of 10
Power Electronics - Wikibooks, open books for an open world 04/02/18, 6*14 PM

Pump Application Speed Characteristics Fig. 30-31 are speed vs. time curves for comparison to the across-the-line
start.

Figure 30: Soft Start [8]

Figure 31: Current Limit [8]

Pump Application Stall Conditions


With a pump application there is almost no starting torque, and the soft start option almost cannot fault. However,
the current limit has an inherent dip in its starting profile, and again, caution must be taken to avoid stall conditions.
Fig. 32 has a current limit set to 200% of the FLA and the motor starts to stall at around 50% of its full speed
(highlighted by arrow).

Figure 32: Pump Stall [8]

Conclusion
A soft starter is a versatile starter that can take many forms and be used to start many different applications. Along
with protecting applications such as belt conveyors and saw mills, it can help save a great deal of energy by reducing
the starting current and starting torque and help stop numerous conditions that are damaging to motors. Appendix

Figure 33: Kickstart Profile [7]

Figure 34: Low Speed and Low Speed Revering Profile [8]

Figure 35: Speed/Current vs. Torque Curve Explanation [9]

other soft starters


Soft start circuits are useful in many applications, even ones that don't use motors.

For example, when a simple switching regulator is first connected to a simple solar array, the array voltage drops,
causing the regulator to pull more current, causing the array voltage to drop further, causing the regulator to pull even
more current, and so on. The result is "voltage collapse" with the system locking up in an undesirable state.[10][11]

Soft-start circuits are one solution to this latchup problem.

References
1. ST Application note AN3169 (http://www.st.com/internet/com/TECHNICAL_RESOURCES/TECHNICAL_LITERAT
URE/APPLICATION_NOTE/CD00266636.pdf): "Technology performance comparison of Triacs subjected to fast
transient voltages"
2. ST Application note AN3168: "Non-insulated SCR / Triac control circuits" (http://www.st.com/internet/com/TECHN

https://en.wikibooks.org/wiki/Power_Electronics Page 9 of 10
Power Electronics - Wikibooks, open books for an open world 04/02/18, 6*14 PM

ICAL_RESOURCES/TECHNICAL_LITERATURE/APPLICATION_NOTE/CD00266635.pdf): "snubberless or logic


level Triac ... can not be triggered in Q4. ... negative power supply ... topology is the preferred one. The gate
current is sunk from the gate by the control circuit. The device then works in Q2 and Q3 quadrants."
3. NXP application note: "Thyristors & Triacs - Ten Golden Rules for success in your application" (http://www.nxp.co
m/documents/application_note/AN_GOLDEN_RULES.pdf)
4. ST application note AN307: "Use of triacs on inductive loads" (http://www.st.com/internet/com/TECHNICAL_RES
OURCES/TECHNICAL_LITERATURE/APPLICATION_NOTE/CD00003855.pdf): "Gate control by DC guarantees
ideal firing but has the disadvantage of high consumption, specially when the control power supply is provided by
the mains. In this case, it is preferable to use a negative current for the gate control (quadrants II and III)."
5. "Soft Starters" http://pages.google.com/edit/jszagorski/EE572_revFinal.pdf
6. Rod Elliott. "Inrush Current Mitigation". 2010. [1] (http://sound.westhost.com/articles/inrush.htm)
7. Allen-Bradley Company, “Bulletin 150 Application and Product Guide,” Sept. 1998.
8. Allen-Bradley Company, “Bulletin 150 Application and Product Guide,” Sept. 1998.
9. Allen-Bradley Company, “Bulletin 150 Application and Product Guide,” Sept. 1998.
10. Jerrold Foutz. "Solar-Array Power System Battery Lockup" (http://www.smpstech.com/solar000.htm). 1996 -
2003.
11. "Simple Soft-Start Circuitry Provides Long Startup Times" (http://electronicdesign.com/article/power/simple-soft-st
art-circuitry-provides-long-startup-). Electronic Design. 1998.

[1] Larabee, J., Pellegrino, B., Flick, B., “Induction Motor Starting Methods and Issues,” IEEE PCIC-2005-24.
[2] Lukitsch, W.J., “Soft Start Vs AC Drives – Understanding the Differences,” Proc. IEEE Annual Textile, Fiber
and Film Industry Technical Conference Atlanta, GA, May 1999, pp. 1-5.
[3] McElveen, R.F., Toney, M.K., “Starting High-Inertia Loads,” IEEE Trans. Ind. Appl., vol. 17, no. 1,
January/February 2001
[4] Unknown, “Soft Starters for Induction Motors,” 2002, http://www.lmphotonics.com/sstart.htm
[5] Allen, J.P.C., “Starting Now: A review of reduced voltage ac motor starters.,” Proc. IEEE Annual Textile, Fiber
and Film Industry Technical Conference Charlotte, NC, May 1992, pp. 1-10.
[6] Mungenast, J., “Design and Application of a Solid-State AC Motor Starter,” IEEE Trans. Ind. Appl., vol. IA-12,
no. 1, January/February 1976, pp. 39-42.

Further reading
Energy and Power: Production, Distribution, and Society
Basic Electrical Generation and Distribution
Electric Motors And Generators
Energy Efficiency Reference
Embedded Systems/High-Voltage Circuits
Practical Electronics/Crowbar circuit

Retrieved from "https://en.wikibooks.org/w/index.php?title=Power_Electronics&oldid=3339782"

This page was last edited on 6 December 2017, at 19:50.

Text is available under the Creative Commons Attribution-ShareAlike License.; additional terms may apply. By using
this site, you agree to the Terms of Use and Privacy Policy.

https://en.wikibooks.org/wiki/Power_Electronics Page 10 of 10

Vous aimerez peut-être aussi