INSTALLATION REPORT

Type: ftanufacturer: Date of Installation: Well: Quote No:

Tbg Size: Tbg Len: No of Jts: Base of Unit: Cable: Supv:


ft
Csg 1 Size: Csg @: Perfs: Length: Crew:
ft ft Cable 1 ft
Csg 2 Size: Top @: Total Depth: Length:
ft ft Cable 2 ft
Csg 3 Size: Top @: Protectliser/No: Splices: Rig:
ft Reel No:

Shroud: Shroud len: Cble Prot No: Customer Rep:


ft Surface Cable:

Motor Flat Cable S/N Length Model Total Length WHC Type Upper connector S/N WH PENETRATOR S/N lower connector S/N

Pump S/N Type Stages Model Length Coating P/N Primary V Step Down Transforfter Step Up Transforfter

Pump Head Size Size

Tap V: Volts: Volts:


kVA kVA
Genset kVA Skid Type: SCADA PS: YES NO J Box: YES NO

Skid S/N: B'Spin Relay: YES NO Sensors: YES NO

Motor Controller: Ext. signals: YES NO Others: YES NO

Intake / Gas Sep S/N Type Model Length Coating P/N TVSS S/N Fixed Speed Drive Variable Speed Drive

V / A: kVA:

Seal S/N Type Model Length Coating P/N Resistance 1*2 1*3 2*3 1*G 2*G 3*G

Mtr

Cble

Motor S/N HP VA Model Length Coating P/N 1*2 1*3 2*3 1*G 2*G 3*G

Motor Head: Mtr/Cable Surface

Mtr/Cable Bottoft

Reftarks

Sensor S/N Model Length Coating P/N

Unit Base:
PULL OUT REPORT
Date Installed: Date Commissioned: Date Failed / Switched Off for Pull: Date Pulled: Quote No:

Pull Reason: Manufacturer: Well No: Length: Reel #: Size: Team Leader:

Fuses Cleared: Cable Damaged on Pulling: Mtr/Cable 1*2 1*3 2*3 1*G 2*G 3*G Team Members:

BIW Condition: Tubing Crossover Condition: Mtr/Cable


W W W W W W Corrosion Damage
Bottom
Tubing Condition: Paraffin: Mtr/Cable
W W W W W W
Surface
Cable Condition: Sand: Cable
MW MW MW MW MW MW
Bands Damaged: Scale: Comments:

Bands Missing: Foreign Material:

Pres. Sensor SN: Condition: Motor Flat SN: Condition: Shroud Hanger Corrosion:

Pump Part No. Pump Serial No. Type Stages Model Pump Condition Pump Clear Pump Plug Pump Loose Pump Free Pump Stiff Pump Lock Shaft Break

Intake Part No. Intake Serial No. Type, UT/LT, Model, Intake Condition Int. Clear Int. Plug Int. Loose Int. Free Int. Stiff Int. Lock Shaft Break

Seal Part No. Seal Serial No. Type, Model, HL/Std Seal Condition Seal Good Seal Dry Seal Wet Seal Free Seal Stiff Seal Lock Shaft Break

Motor Part No. Motor Serial No. H.P. Volts Amps Motor Condition Motor Wet Motor 1*2 1*3 3*3 1*G 2*G 3*G

Resistance

Resistance

Resistance

Resistance
COMMISSIONING REPORT
Well: Date: On location Unit start
time: time:
Field: Install Date:

Resistance Readings A-B A-C B-C A-Grd B-Grd C-Grd

Cable & Motor Bottom

Voltage Readings A-B A-C B-C A-Grd B-Grd C-Grd

No Load

Load

Control C.T. Starting Amperage Running Amperage


Fuse Size
Voltage Ratio A B C A B C

CONTROLLER SETTINGS DOWNHOLE SENSOR READINGS

Restart Over Under Over Under Static BHP Start MTR 1 Hr. BHP 1 Hr. MTR

Timer Voltage Voltage Load Load PSI Temp. F PSI Temp. F

Variable Speed Drive Choke Wellhead Flowline Casing Pr. Switch

Mode Hz. Max. Hz Min. Hz Setting PSI PSI PSI PSI

SW.B/VSD S/N: Volts/Amps: TVSS S/N: Voltage:

XFMR S/N: 123444 kVA: Voltage Range: SKID NO:


Cntr Type: S/N: Display: S.WHC S/N: Type:

DHMS SU S/N: DHT Chk S/N: EPRM Rev: DHT Brd S/N:

Motor HP. Volts: Amps: Pump Type: Stages:


Action Taken:

Further Action Required: Responsibility

7 Day Monitoring / Follow up


Suspended Date & Time: Reason:

Work Completed Yes No Unit Running Yes No

Alkhorayef Petroleum Commissioning Engineer:

Customer Rep.:
MONITORING REPORT (7 Days)
Field Well Install Date Commission Date Type of well fluid

Motor
Motor HP, Voltage, Frequency, Flc Transformer Tapping Voltage Pump SW.B
Loading

Tap No. Voltage Type Stages BHP CT ratio Fuse Size

Total Run Time Total Measured Pump Tubing


Pump Casing Flow line Choke
Monitoring Date Phase Voltage Actual Amps Settings Freq. Run From Number Fluid Lvl Discharge Head
Intake Pr. Pressure pressure Size
Hrs. Start Of Starts. TVD (Daily) Pr. Pressure

A B C A B C U/L O/L Hz Hrs Hrs No ft psi psi psi psi psi inch

Start-up

Day1

Day2

Day3

Day4

Day5

Day6

Day7

Days

Notes & Observations ( Non attendance / delays / Problems / unusual events / Suggestions for Improvement )

Signed ( Alkhorayef )

Page 4 of 6 02/05/2018
Gross
Flow
Rate

BPD

Page 5 of 6 02/05/2018
ESP Field Failure Analysis Report
Date: Customer: Well:

Field observations Test results


Power Cable Pumps Wellhead Pump
Good Smooth HHS Good

Blown Turn tight EFT Bad

Short Locked up Seaboard Bad shaft play

Insulation loose Bad shaft play Mandrel Bad vibrations

Heat damage Bent shaft Good B-line

Gas blown No shaft movement Grounded Splines bad

Splice short Broken shaft Blown Twisted shaft

Splice blown Intake / Gas Sep. Upper pigtail Incorrect shaft ext.

Pothead burn Clean Good Motor

MLE burn Plugged Grounded Good

MLE splice blown Bad shaft play Blown Burned

Wellhead packoff burn Locked up Lower pigtail Wet

Bands Good Bad

Type: Seal bottom chamber Grounded Bad vibrations

Tight Clean oil Blown Hot spots

Missing Discolered oil Surface equipment Short spin

Loose Water Fuses blown Will not dry out

Corrosion Well fluid Surface cable grounds Intake / Gas Sep.

Snagged Dry L. arrestor blown Good

Poor crimp Bad shaft play Primary fuses blown Bad shaft play

Tubing Broken shaft Amp chart Lock up

Clean Motors Controller bad Tight

Plugged Turns smooth Bad corrosion

Paraffin Turns tight Washed out

Scale Clean oil Serviceman Seal

Drag marks Dirty oil Spooler Good

Corrosion No oil Rig # Bad

Foreign matter Shavings Crew Chief Bad top seal

Asphaltine Water Water in lower chamber

Plastic coated Drag marks on hsg Bad thrusts test

Pothead burn Plugged compensator tube

Equipment description and test results:

Service Technician comments:

Comments and proposed reason for failure: