Vous êtes sur la page 1sur 11

MATLAB/SIMULINK Based Modelling

Photovoltaic Array Fed T-Source Inverter


G. Hemaprabha, R. Kiruthika, P. Vijayasalini
Assistant Professors, Department of EEE, Info Institute of Engineering, Coimbatore, India

International Journal of Research in Electrical & Electronics Engineering


Volume 2, Issue 4, October-December, 2014, pp. 20-30
ISSN Online: 2347-5439 Print: 2348-0025, DOA : 19112014
© IASTER 2014, www.iaster.com

ABSTRACT

In order to utilize the solar energy for industrial, commercial and domestic applications the power
conversion schemes plays an important role. The problem exists in conventional power conversion
schemes are low efficiency, poor transient response, low voltage gain and more reactive components
are being used .This paper proposes a single stage power conversion scheme called T-source
inverter(TSI) to overcome these drawbacks. T-Source inverter (TSI) with simple boost control scheme
is used as interface circuit between PV array and load. The PV array is analyzed under different
irradiation and temperature value. The mathematical equations are verified with simulation and
hardware. The verification shows the voltage gain of TSI was comparatively higher than ZSI. The
reactive components in the circuit are less, fast transient response and low output ripple.

Keywords: PV cell, T-source Inverter-Source inverter, Voltage Source Inverter, Simple Boost Control.

1. INTRODUCTION

Due to increase in energy consumption and depleting of fossil fuels the renewable energy sources
have become cynosure of all eyes. Nowadays solar and wind energy power generations are rapidly
grown when compared to other renewable source. In India solar potential is high and wind power
generations have the limitation of medium wind profile, low plant factor and saturation of optimal
wind locations. Solar irradiation is abundant in India by figures (4 -7) kw/m2 per day in all over the
country with 300clear sunny days in a year. The 70% of Indian population are involved in agricultural
and living in rural areas. Still 1/3rd of Indian population are not connected to grid electric supply [*]
for that reason photo voltaic distributed power generation is most popular.

Two methods are available to convert solar energy into alternating current (AC) supplies are 1.)
Single stage conversion 2.) Two stage conversions. These days single stage conversions are more
popular than two stage conversion because of reduced system size, cost and high efficiency.

DC to DC PV TRANS-
PV DC TO AC LOAD
ARRAY
Boost DC to AC LOAD ARRAY FORMER
Conversion

Fig.1.A Two Stage Power Conversion Fig 1.B Two Stage Power Conversion

PV
ARRAY
DC TO AC LOAD

Fig.1.C Single Stage Power Conversion

20
International Journal of Research in Electrical & Electronics Engineering (O) 2347-5439
ISSN
Volume-2, Issue-4, October-December, 2014, www.iaster.com (P) 2348-0025

Conventional methods of photovoltaic energy conversion systems are suffer from voltage buck boost
capability in single stage. It is possible with Z-source inverter, but this type of inverter has some limitations
like more reactive components, high ripple contents and occupies more space. When compared to z-
source inverter T-source inverter has few reactive components and high voltage gain. High voltage gain is
possible by adjusting the number of turns in coupled inductor of T-network. This T-source inverter has the
L and C impedance network in T-shape combined with Voltage source inverter (VSI).

II. PV ARRAY MODEL

The equivalent electric circuit model of PV cell is


used here for implementation in MATLAB. The
equivalent circuit models of PV cells are connected
in series and parallel combination to attain desired
output voltage and power of PV array.

Fig.2.1 Equivalent Circuit of Photovoltaic Cell

Fig: 2.1 show the simplest model of a PV cell. An equivalent circuit consists of an ideal current
source in parallel with an ideal diode. The current source represents the current generated by photons
(often denoted as Iph or IL), and its output is constant under constant temperature and constant incident
radiation of light. The photon generated current will follow out of the cell as a short-circuit current
(Isc). Thus, Iph = Isc. Assume that output is in open-circuit, the photon generated current is shunted
internally by the intrinsic p-n junction diode. This gives the open circuit voltage (Voc). The output
current (I) from the PV cell is found by applying the Kirchoff‟s current law (KCL) on the equivalent
circuit shown in Fig.2.1.
V
I sc  I d  d  I PV  0 (1)
RP
Where:
Isc is the short-circuit current that is equal to photon generated current
Id is the current shunted through the intrinsic diode
Vd is the voltage across the diode (V)
RP=RSH is Parallel Resistance (ohm)

Table1: Electrical Characteristics of PV Array

S.No Parameter Value


1 Maximum power (Pmax) 180W
2 Voltage at Pmax (Vmpp) 35.8V 31.9V
3 Current at Pmax (Impp) 5.03A 4.02A
4 Short circuit current (Isc) 5.58A 4.52A
5 Open circuit voltage (Voc) 43.6V 39.7V
6 Module efficiency 14.4%
7 Tolerance -3/+5%
8 Nominal voltage 24V
9 Limiting reverse current 5.58A
10 Temperature coefficient of Isc (0.065±0.015)%/ºC
11 Temperature coefficient of Voc -(0.36±0.05) %/ºC
12 Temperature coefficient of Pmax -(0.5±0.05) %/ºC
13 Maximum series fuse rating 20A

21
International Journal of Research in Electrical & Electronics Engineering (O) 2347-5439
ISSN
Volume-2, Issue-4, October-December, 2014, www.iaster.com (P) 2348-0025

The diode current Id is given by the Shockley‟s diode equation:


I d  I o (eqVd / kT  1) (2)
Where:
Io is the reverse saturation current of diode (A)
q is the electron charge (1.602×10-19 C)
Vd is the voltage across the diode (V)
K is the Boltzmann‟s constant
(1.381×10-23 J/K),
T is the junction temperature in Kelvin (K)

Applying the Kirchoff‟s voltage law (KVL) on the equivalent circuit shown in Fig.2.1

VPVcell  Vd  Rs I PV (3)

Replacing Id of the equation (1) by the equation (2) gives the current-voltage relationship of the PV
cell.
I  I sc  Io (eqV / kT  1) (4)
Where:
V is the voltage across the PV cell
I is the output current from the cell

The reverse saturation current of diode (Io) is constant under the constant temperature and found by
setting the open-circuit condition as shown in Fig.2.5 (b). Using the equation (4), let I = 0 (no output
current) and solve for Io.
I
Io  sc
(5)
e qVoc / kT
1
To a very good approximation, the photon generated current, which is equal to Isc, is directly
proportional to the irradiance, the intensity of illumination, to PV cell. Thus, if the value, Isc, is known
from the datasheet, under the standard test condition, Go=1000W/m2 at the air mass (AM) = 1.5, then
the photon generated current at any other irradiance, G (W/m2), is given by:
G
I sc I G    I sc I Go (6)
 Go 
The PV cell output is limited by both cell current and the cell voltage, and it can only produce a power
with any combinations of current and voltage on the I-V curve. It also shows that the cell current is
proportional to the irradiance. To realize the PV array characterics in MATLAB BP 4180T PV panel
data sheet is used for simulation. The specification of PV panel is given in table 1.

BP 4180T PV panel are simulated using Matlab. The open circuit voltage, short circuit current and the
maximum power are greatly affected by change in atmospheric conditions such as temperature and
irradiation.

Fig2.4 illustrates the V-I Characteristics of the specified PV array, which is simulated with constant
temperature (250 C) and different irradiation. From this we infer that irradiation is directly
proportional to open circuit voltage and short circuit current.

22
International Journal of Research in Electrical & Electronics Engineering (O) 2347-5439
ISSN
Volume-2, Issue-4, October-December, 2014, www.iaster.com (P) 2348-0025

Fig. 2.2 V-I Characteristics of PV Panel With Irradiation of 1000 W/M2 and Different Temperature

V-I characteristics of the specified PV module with respect to different temperature and constant
irradiation(1000w/m2) is shown in fig.2.2 From the figure we infer that the significance of the
temperature is, when temperature changes open circuit voltage get decreased and short circuit current
is slightly increased.

Fig.2.5 P-V Characteristics of PV Panel with Temperature 250C and Different Irradiation

Fig.2.5 illustrates the P-V characteristics of BP 4180T PV panel with temperature of 250C and
different irradiation condition .When the irradiation increases the PV panel output voltage and power
gets increased.

III. T-SOURCE INVERTER

T – Source inverter (TSI) overcomes the limitation of traditional voltage source inverter and current
source inverter. Both inversion and boost function are being accomplished in a single stage using the
TSI, there by reducing conversion loss. Unlike the traditional inverter, TSI utilizes a unique
impedance network that links the inverter main circuit with the PV (or DC) source. Fig. 2.3 P-V
characteristics of PV panel with irradiation of 1000 w / m2 and different temperature.

P-V Characteristics of PV array with constant irradiation and variable temperature is shown in fig.2.3.By
increasing temperature output voltage and maximum power point get decreased; the maximum power and
open circuit voltage are inversely proportional to temperature at constant irradiations.

Fig.2.5 P-V Characteristics of PV Panel with Temperature 250C and Different Irradiation

23
International Journal of Research in Electrical & Electronics Engineering (O) 2347-5439
ISSN
Volume-2, Issue-4, October-December, 2014, www.iaster.com (P) 2348-0025

Working Principle

The DC voltage (from PV) is fed as input to the impedance network of TSI which helps to achieve
voltage buck and boost properties. Then the output of the impedance network is applied to the inverter
main circuits which comprising of six switches. The voltage boost capability of TSI is facilitated by
turning ON both the switches in the same phase leg simultaneously. Voltage boost capability of TSI is
due to energy transfer from capacitors to inductors, during the shoot through state. Since, the
capacitors may be charged to higher voltages than the source voltage, the diode „D‟ prevents
discharging of capacitors through the source.

As with conventional ZSI, the TSI can handle shoot through states when both switches in the same
phase leg are turned on. The T-network is used instead of the lattice impedance-network, for boosting
the output voltage by inserting the shoot through states in the pulse width modulation (PWM)
schemes. The operating principle of T – Source Inverter is same as that of conventional ZSI [2] but it
differ from number of capacitor being used. In proposed TSI, only one capacitor is enough to handle
shoot through state where as in ZSI two capacitor were used. The detailed operation of TSI is
explained in two modes as: a) Non shoot through mode b) Shoot through mode

A) Non – Shoot Through Mode

Fig.3.1 illustrates the equivalent circuit of TSI in Non – shoot through mode of operation. In this
mode capacitor is charged, the inverter bridge operate
in one of traditional active states, thus acting as a
current source when viewed from T – source circuit.
During active state current is zero because of open
circiut. The open circuit voltage appear across inverter
bridge. The diode conduct and carry current
difference, between the inductor current and input DC
current. Note that both the inductors have an identical
current because of coupled inductors.
Fig.3.1: Non – Shoot Through Mode
Assume:
Drop across diode is negligible.
For symmetrical T network
L1=L2; VL1=VL2=VL,
Total switching period (Tt) = T1+T0
T1-Non shoots through time period (active state)
T0-Shoot through time period (zero state)
From non-shoot through mode for the time period of T1

Vi = Vdc (3.1)
Vi = VL1+Vc
Vc = Vi- VL (3.2)
VL = Vi-Vc
Vout = Vc- VL2
Vout = Vc- VL
Vout = 2Vc-Vdc; Vi=Vdc (3.3)

24
International Journal of Research in Electrical & Electronics Engineering (O) 2347-5439
ISSN
Volume-2, Issue-4, October-December, 2014, www.iaster.com (P) 2348-0025

B) Shoot Through Mode

This shoot through zero state prohibited in traditional


voltage source inverter. It can be obtained in three
different ways such as shoot through via any one phase
leg or combination of two phase leg or combination of
three phase leg. During this mode, Diode is reverse
biased capacitor charges the inductor L2 separating DC
link from the AC line.
Fig.3.2 Shoot Through Mode
Inverter in shoot through mode for the time period of T0
Vc = VL2 (3.4)
VC = VL
Vout = 0 (3.5)

At steady state the average voltage of the inductor for one switching period (Tt) is zero.
From equation (3.2) &(3.4)
V To +T1 (Vdc -Vc )
VL = c =0
T
Vc T
= 1 (3.6)
Vdc T1 -T0
T1
Vc = V (3.7)
T1 -T0 dc
The average dc link voltage across T source inverter bridge is,
0 To + (2Vc -Vdc ) T1
Vdclink =
T
T1
Vdclink =Vdc
T1 -T0
Vdc link = Vc (3.8)
The Peak dc link voltage across inverter bridge can be written as

Vdc link peak =Vc -VL = 2Vc -Vdc

T
Vdc link peak =Vdc (3.9)
T1 -T0

= B Vdc (3.10)
T
B=
T1 -To
1
B= 1
T
1-2 o
T
(To / T)= D0 is shooting through duty ratio

Boost factor depends on shoot through zero time period (T0).The peak dc-link voltage is the
equivalent dc-link voltage of inverter.

25
International Journal of Research in Electrical & Electronics Engineering (O) 2347-5439
ISSN
Volume-2, Issue-4, October-December, 2014, www.iaster.com (P) 2348-0025

Vdc link peak


Vac =M i (3.11)
2
M i -Modulation index
Peak phase value of out put voltage of inverter is
^ V
Vac =M i B dc (3.12)
2
Bb = Mi B = (0 ~ ∞)
Bb - Buck boost (gain) factor

The capacitor voltage can expressed as

T
1- 0
Vc = T V (3.13)
T dc
1-2 0
T

IV. RESULTS AND DISCUSSION

Simulations were done with MATLAB software. PV array performance was analyzed by changing
temperature and irradiation condition. Fig. 4.1 shows the circuit configuration of T-source inverter
connected with PV array for three phase R-L load and Fig. 4.2 shows simulation waveforms, where
PV array is simulated based on BP 4180T manufacturer data sheet. PV array voltage is, V0C=100V,at
standard temperature of 250C and1000w/m2 irradiation.

Fig.4.1 Circuit Configuration of T-Source Inverter

T source inverter consists of T network and voltage source inverter. T network consists of coupled
inductor (L) and one capacitor(C) connected in T shape is illustrate in fig.4.1 The diode D used to
block the revese current flow to load during shoot through zero state.T source inverter is connected to
three phase RL load. The proposed system produces 3-phase 183 V rms from the PV array voltage of
100V dc. From Fig. 4.2, it is clear that the output line-to-line voltage is 150V rms or 259V peak. In
this case, the modulation index was set to Mi=0.6, the shoot-through duty cycle was set to (D0=T0/T)
= 0.4, and its switching frequency to 5 kHz.
T
B= ;
T1 -To
1
B= = 0.5;
T
1-2 o
T

26
International Journal of Research in Electrical & Electronics Engineering (O) 2347-5439
ISSN
Volume-2, Issue-4, October-December, 2014, www.iaster.com (P) 2348-0025

^ 100
Vac  0.6  5  ;
2

^
Vac  150v
^
Vac - peak phase voltage of the inverter

V. SIMULATION RESULTS

Table 3.1 shows the system parameters used for simulation. The performance of the T-source inverter was
tested under simple boost control method. Its characteristics and relative results are discussed in this section.
Table2: System Parameters
Parameter Specification
Input voltage(Vdc) 100 V
Modulation index (Mi) 0.6
Switching frequency 5000 Hz
Shoot through duty ratio (D0) 0.4
C 1000 μF
L1=L2=L 1 mH
RLoad 10 Ohms
LLoad 5 mH

The Input voltage(Vin), inductor current(IL),capacitor voltage(Vc),inverter line to line voltage


without filter (VL),load current(IL),voltage across load (VLL),and transient voltage of capacitor for
both ZSI and TSI (Vc) are shown in fig 4.2 from top to bottom respectively.

1000

500
VL(V)

-500

-1000
2200 2250 2300 2350 2400 2450 2500
Time(ms)

Fig.4.2 Simulated Wave Form of T-source Inverter

27
International Journal of Research in Electrical & Electronics Engineering (O) 2347-5439
ISSN
Volume-2, Issue-4, October-December, 2014, www.iaster.com (P) 2348-0025

Transient response is good and ripple content is less in TSI when compared to ZSI because coupled
inductor is used in TSI where as in ZSI separate inductors are used. One more advantage of coupled
inductor is, it occupies less space hence there is reduction in its size and cost.

T –source inverter performance is analyzed by varying the shoot through duty ratio and modulation
index, those results are shown in table3.Shoot through duty ratio (D0) is directly related to boost factor
(B)by, increasing boost factor value, increases the output voltage. To maintain constant output voltage
across the load irrespective of input voltage variation, the shoot through duty ratio (D0) is adjusted.

Table 3: System Parameter Variations with Respect to Modulation Index and Shoot through Duty Ratio

Vdc
Mi D0 link Vrms Irms
0.6 0.4 304 183.5 6.4
0.3 241 134 5.2
0.2 197 93 4.3
0.1 167 57 2.9
0.7 0.3 238.7 136.5 5.3
0.2 190 94 4
0.1 152.2 58 2.5
0.8 0.2 188.6 97 3.9
0.1 144.2 61 2.2
0.9 0.1 140.8 61.5 2

Fig 4.3 Harmonic Spectrum of the Output Fig 4.4 Harmonic Spectrum of the Output Voltage
Current

Table4: Harmonic Profile


ZSI Proposed TSI
D0 V_thd I_thd V_thd I_thd
0.4 42.2 5.02 27.1 4.79
0.3 41.9 4.9 27.1 4.59
0.2 40.9 4.7 26.95 4.05
0.1 40.2 4.62 26.9 4.03

The harmonic profile of the output voltage and current of TSI with simple boost control method is
given in Table 4. Total harmonic distortion of proposed TSI is low compared to Z-Source inverter of
same rating. Fig4.3and Fig.4.4 illustrates the harmonic spectrum of load current and load voltage.

28
International Journal of Research in Electrical & Electronics Engineering (O) 2347-5439
ISSN
Volume-2, Issue-4, October-December, 2014, www.iaster.com (P) 2348-0025

VI. EXPERIMENTAL RESULT


The proposed inverter in this paper was verified experimentally using hardware. Captured waveform
is same as proven conceptually in earlier sections. The figure show input voltage and output voltage
of T-source inverter respectively, which are quite consistent with simulation results.

Fig.5.1 Input Voltage to T-source Inverter Fig 5.2 Output Voltage of TSI

VII. CONCLUSION
In this paper T-source inverter with simple boost control technique has been introduced for
photovoltaic applications. The mathematical model of T-source inverter is derived and it is simulated
in MATLAB software. The PV array simulations were done with BP4180T data sheet. By controlling
modulation index and shoot through duty ratio, boost factor value gets varied; there by the designed
output voltage can be obtained. Finally the proposed inverter is implemented in hardware, its
performance under change in temperature and irradiation conditions were analyzed. The results shows
proposed T-source inverter gives high voltage gain, improved transient response and reduction in
Total harmonic distortion when compared to conventional z-source inverter.

REFERENCES

[1] The European Union climate and energy package, (The “20 – 20 – 20”package)
http://ec.europa.eu/clima/policies/eu/package_en.htm.

[2] D. JC. MacKay, “Sustainable Energy - Without the Hot Air”, UIT
Cambridge,2009http://www.inference.phy.cam.ac.uk/sustainable/book/tex/cft.pdf

[3] J. Anderson and F.Z. Peng, “Four Quasi-Z-Source Inverters”, Proc. of IEEE PESC 2008, 15-19
June 2008, pp . 2743 – 2749,.

[4] J. Anderson and F. Z.Peng, “A Class Of Quasi-Z-Source Inverters”, in Proc. of 43rd IAS
Annual Meeting, 2008, pp. 1-7.

[5] F.Z.Peng, “Z-Source Inverter”, Proc. of the 37th IAS Annual Meeting, 2002, pp.775-781.

[6] F.Z Peng, “Z-Source Inverter”, IEEE Trans. on Industry Applications, Vol.39, No.2,2003,
pp.504-510.

[7] J. Anderson and F.Z Peng, “Four Quasi-Z-Source Inverters”, Proc. of IEEE PESC, 15-19 June
2008, pp . 2743 – 2749.

29
International Journal of Research in Electrical & Electronics Engineering (O) 2347-5439
ISSN
Volume-2, Issue-4, October-December, 2014, www.iaster.com (P) 2348-0025

[8] Ryszard Strzelecki, Marek Adamowicz and Natalia Strzelecka , “New Type T-Source
Inverter”, Power Quality, Alternative Energy And Distributed Systems,2009, pp.191-195.

[9] J. Surya Kumari and Ch. Sai Babu, “Mathematical Modeling and Simulation of Photovoltaic
Cell using Matlab-Simulink Environment”, International Journal of Electrical and Computer
Engineering (IJECE) Vol. 2, No. 1,2012,pp .616-623.

[10] Tarak Salmi, Mounir Bouzguenda,Adel Gastli and Ahmed Masmoudi, “MATLAB/Simulink
Based Modelling of Solar Photovoltaic Cell” in International Journal of Renewable Energy
Research Vol.2, No.2, 2012,pp. 213-218.

[11] Photovoltaic Model Datasheet “ Sun Power E-20/327W”

[12] Seok-Il Go, Seon-Ju Ahn and Joon-Ho Choi,“Simulation and Analysis of Existing MPPT
Control Methods in a PV Generation System”, Journal of International Council on Electrical
Engineering Vol. 1, No. 4, 2011, pp. 446-451.

[13] Mingwei Shan, Liying Liu, and Josep M. Guerrero, “A Novel Improved Variable Step-Size
Incremental-Resistance MPPT Method for PV Systems”, IEEE Transactions on Industrial
Electronics, Vol. 58, No. 6,2011,pp. 2427-2434.

[14] Fangrui liu, Shanxu duan, Fei liu, Bangyin liu, and Yong kang, “A Variable Step Size INC
MPPT method for PV systems”, IEEE Transactions On Industrial Electronics, vol. 55, No. 7,
july 2008,pp. 2622-2628.

[15] S. Thangaprakash and A. Krishnan, “Modified Space Vector Pulse Width Modulation for Z-
Source Inverters”, International Journal of Recent Trends in Engineering, Vol 2, No. 6,
November 2009,pp. 136-138.

[16] Jingbo Liu, Jiangang Hu and Longya Xu, “A Modified Space Vector PWM for Z-Source
Inverter - Modeling and Design”, IEEE Transc. Power Electron ,pp. 1242-1247.

[17] Jin-Woo Jung and Ali Keyhani, “Control of a Fuel Cell Based Z-Source Converter”, IEEE
Transactions On Energy Conversion, Vol. 22, No. 2, June 2007,pp. 467-476.

[18] Sengodan Thangaprakash, “Unified MPPT Control Strategy For Z-Source Inverter Based
Photovoltaic Power Conversion Systems”, Journal Of Power Electronics,Vol.12, No.1, January
2012,pp. 172-180.

[19] Sivaraman and Nirmalkumar, “Analysis of T-Source Inverter with Various PWM Schemes”
European Journal of Scientific Research ISSN 1450-216X Vol.71, No.2,2012, pp. 203-213.

30