Vous êtes sur la page 1sur 14

« laboratory analyzers buyers guide »

• Automation
The ADVANCE 14th Annual Abbott Diagnostics

Laboratory
100 Abbott Park Rd.
Abbott Park, IL 60064
Contact:
Telephone: (800) 323-9100

Analyzers
www.abbottdiagnostics.com
Primary Product:
Diagnostics equipment and reagents
Type of Analyzer:
Chemistry, immunoassay, blood banking,
>>
Buyers
hematology, automation, rapids

Beckman Coulter Inc.

Guıde
200 S. Kraemer Blvd.
Brea, CA 92822
Contact:
EDITOR’S NOTE: The ADVANCE 14th Edward Sheridan
Automation Tactical Marketing Manager
Annual Laboratory Analyzers Buyers
ejsheridan@beckman.com
Guide represents a collaborative effort
www.beckmancoulter.com/automation
between ADVANCE editorial consultants/ Primary Product:
advisors, industry manufacturers and Power Processor
editorial staff. This year’s guide includes Type of Analyzer:
detailed information on a product’s Scalable Lab Automation
test menu, features, operational types Integrated Data Management:
and more. Listings do not represent Yes
endorsement by ADVANCE. What differentiates your product from
other products on the market?
Beckman Coulter offers more than
30 open, scalable connections
to fit your lab’s needs

Olympus America Inc.


3500 Corporate Parkway
Center Valley, PA 18034
Category Key Contact:


↓red
• Automation
Hiroshi Sekiya
Director, Automation and Integration
Telephone: 972-556-9697
↓   Diagnostics
blue

• Cardiac hiro.sekiya@olympus.com
www.olympusamerica.com
↓  
green
Primary Product:
• Chemistry OLA2500
↓  
sky blue Throughput:
• Coagulation Up to 1,200 tubes per hour sorting
Integrated Data Management:
↓Brown 
• Drug Testing Yes
Open Reagent System:
↓purple  No
• Hematology Primary Tube Sampling:
↓  
orange Yes
• Immunoassay Positive Sample ID:
Yes
↓  
pink

• Nephelometry Onboard Dilution:


No
↓  
gray

• Tissue Processing What differentiates your product from


john ciuppa

other products on the market?


Modular, open lab automation system
s

88 | July 2007 • advance /Laboratory • www.advanceweb.com


Circle 67 on FREE Information Card
« laboratory analyzers buyers guide »
for pre- and post-analytical sample ADVIA 1800/2400 and Immulite. What differentiates your product from Contact:
management; automates sample Operational Type: other products on the market? Tina Johne
check-in, selectively decaps, sorts, Continuous or batch Designed to fit in various settings: Head Global Communications
aliquots and archives; processes a Sample Handling System: emergency department, stat lab, chest Telephone: (914) 524-2429
variety of tubes and accommodates Up to 10–100 position barcoded pain center, CCU and ICU; and offers a Fax: (914) 524-3693
most analyzer-specific racks sample racks/sample manager unit hsTnI method that meets the ACC/ESC tina.johne@siemens.com
Operational Type: guidelines for Troponin performance http://diagnostics.siemens.com
Walkaway Capacity in
Continuous or batch Specimen/Tests Assays: (less than or equal to 10% CV at the Primary Product:
Separation Methodologies: 1000 samples per sample manager 99th percentile of a normal reference Clinitek ATLAS; Clinitek Advantus
N/A (configurable: up to 4 sample managers) population). Offers the first high- Type of Analyzer:
Average Length of System Startup sensitivity CRP assay cleared by the Clinitek ATLAS: fully automated
Sample Handling System:
Time and Daily Maintenance: FDA as an independent marker for risk urine chemistry analyzer; Clinitek
Racks/trays
assessment and for risk stratification Advantus: semi-automated
Walkaway Capacity in Always on: except for once per
urine chemistry analyzer
Specimen/Tests Assays: week 20 minute reboot; <5 in the POC setting. Includes closed
container sampling, onboard sample Methodologies Used:
Up to 300 samples in input area minutes daily maintenance
Drypad measurement; SG by
System Liquid or Dry: preparation, including centrifugation
Dry • Cardiac Diagnostics from the primary collection tube,
refractive index method
Tests Available in the U.S.:
Average Length of System Startup enabling ease-of-use. Provides stat
Leukocytes, ketones, protein, glucose,
Time and Daily Maintenance: Dade Behring quantitative results from a whole blood
nitrite, occult blood, urobilinogen,
2 minutes startup; 5 minutes 1717 Deerfield Rd. sample within 14 minutes. Results
pH, bilirubin, color, specific gravity
daily maintenance Deerfield, IL 60015 are standardized with the company’s
by refractive index method; clarity
Contact: Dimension® family of analyzers in the
by measurement of transmitted and
Siemens Medical Solutions Diagnostics Amy Boyett central lab offering seamless result scattered light color change measured
511 Benedict Ave. Senior Communications Specialist comparison. This benchtop instrument by reflectance photometry. Dual readings
Tarrytown, NY 10591 Telephone: (847) 267-5300 does not require external water or waste at reactive and reference wavelengths
Fax: (847) 236-7101 line connections and offers connectivity
Contact: Throughput:
amy_boyett@dadebehring.com capabilities to hospital or lab information
Tina Johne 1 sample every 16 seconds
www.dadebehring.com systems. The Stratus® CS Acute CareT
Head Global Communications Time to First Result:
Primary Product: System Kiosk can be purchased as a
Telephone: (914) 524-2429 Clinitek Advantus: 90 seconds
Stratus® CS Acute CareT stand-alone workstation featuring its
Fax: (914) 524-3693 Sample Size:
Diagnostic System
tina.johne@siemens.com own lightweight cart, refrigerator and 2 mL
Methodologies Used: power supply and is uniquely designed
http://diagnostics.siemens.com Frequency of Calibration:
Two-site sandwich assay based
Primary Product: for use in the acute care setting. The With every Reagent Pak change (or
on solid phase Radial Partition
ADVIA WorkCell (high-volume chemistry/ SCS is compliant with POCT 1A when every 24 hours when multiple same-lot
Immunoassay (RPIA) technology
immunoassay automation) ADVIA LabCell interfaced with Telcor’s Quick-Linc or Reagent Paks used within 24 hours)
Tests Available in the U.S.:
(fully customizable multidiscipline MAS’ RALS and optional middleware. What differentiates your product from
Acute CareT Troponin I, Acute CareT
automation [chemistry; immunoassay; The Stratus® CS Acute CareT analyzer is other products on the market?
NT-proBNP, Acute CareT Cardiophase®
hematology; coagulation; urinalysis]) not POCT 1A compliant as a standalone. Clinitek ATLAS: Load 490 tests at
hsCRP, D-dimer, Myoglobin, CKMB, ßhCG
Throughput: Operational Type: one time; continuous reagent roll for
Throughput:
Up to 2,000 tubes per hour Continuous random access high reliability of strip transport; fully
8 tests/hour
(configuration dependent) Separation Methodologies: automated; walk-away time with Rack
Time to First Result:
Radial Partition Immunoassay (RPIA) Handler up to 53 minutes; Carousel
Integrated Data Management: 14 minutes to first result; 4
Number of Reagent Containers Sample Handler holds up to 50 samples;
Yes minutes for each additional
Onboard/Tests/Container: Rack Sample Handler holds up to 200
Positive Sample ID: Sample Size:
Single use Test Paks samples; liquid level sensing; true
Yes 3 mL whole blood; 200 µL of plasma
calibration of all analytes; accommodates
Onboard Dilution: Frequency of Calibration: Reagents Refrigerated Onboard:
2 stat samples. Clinitek Advantus:
Yes Every new Test Pak lot; for any one No
throughput up to 500 tests per hour;
What differentiates your product from lot; 30 days for NT-probNP; 60 days Walkaway Capacity in
color touch-screen display; self-paced
other products on the market? for cTnI, CKMB, Myoglobin, hsCRP Specimen/Tests Assays:
sample loading; automatic calibration;
Highest sample throughput currently and D-Dimer; 90 days for ßhCG 1/4 microscopy consolidation; one-touch
available; modular; advance intelligent Integrated Data Management: System Liquid or Dry: switching between strip types; up to
sample process management: automates Yes Liquid three different user-defined confirmatory
sample check in; user-defined pre- and Open Reagent System: Average Length of System Startup flags; one-touch stat interrupt capability
post-analytical sample management— No Time and Daily Maintenance: Sample Handling System:
sorting and archiving, decapping; Primary Tube Sampling: System check EQC (5 minutes); Up to 200 samples at one
centrifugation; automatic rerun, dilution, Yes no daily maintenance time (up to 20 racks)
reflex and test add on capabilities; Positive Sample ID: Number of Reagent Containers
ability to support parallel processing Yes • Chemistry Onboard/Tests/Container:
of any combination of sample tubes. Onboard Dilution: 55 test onboard capacity including ISE
Provides the largest online test menu Yes Bayer HealthCare Diagnostics Division Walkaway Capacity in
for primary sample tube processing Other Utility Requirements: 511 Benedict Ave. Specimen/Tests Assays:
with the combination of ADVIA Centaur, None Tarrytown, NY 10591 Up to 53 minutes
s

90 | July 2007 • advance /Laboratory • www.advanceweb.com


« laboratory analyzers buyers guide »
Average Length of System Startup particle immunoassay detection system Frequency of Calibration: Throughput:
Time and Daily Maintenance: Operational Type: 30 days; within lot calibration available Chemistry: 990/hour;
5 minutes Random access; batch; stat Integrated Data Management: Immunoassay: 100/hour
Separation Methodologies: Yes Time to First Result:
Beckman Coulter Inc. Centrifugation Open Reagent System: Varies; less than or equal to two minutes
200 S. Kraemer Blvd. Sample Handling System: Yes Sample Size:
Brea, CA 92822 Rack Primary Tube Sampling: 2-69 mL
Contact: Number of Reagent Containers Yes Frequency of Calibration:
Daniel Siegenthaler Onboard/Tests/Container: Positive Sample ID: Varies
Market Manger 65/70 up to 400 tests per container Integrated Data Management:
Yes
Telephone: (714) 961-3594 Yes
(photometric); up to 3,200 tests Onboard Dilution:
Fax: (714) 961-3825
per container (modular) Yes Open Reagent System:
dmsiegenthaler@beckman.com
Reagents Refrigerated Onboard: Other Utility Requirements: No
www.beckmancoulter.com
Yes 115 VAC RMS Primary Tube Sampling:
Primary Product:
Walkaway Capacity in What differentiates your product from Yes
UniCel® DxC 800 Synchron®
Specimen/Tests Assays: other products on the market? Positive Sample ID:
Clinical System; UniCel DxC 600
Synchron Clinical System Up to one hour True Rate Nephelometry methodology, Yes
Methodologies Used: System Liquid or Dry: onboard antigen excess checking for Onboard Dilution:
ISE, conductivity, glucose oxygen sensor, Liquid 14 assays and dynamic blanking Yes
photometric, colorimetric, turbidimetric, Average Length of System Startup Operational Type: Other Utility Requirements:
near infrared particle immunoassay Time and Daily Maintenance: Continuous random access Deionized water
Tests Available in the U.S.: None Sample Handling System: What differentiates your product from
More than 100 tests, including Contact: Rack other products on the market?
general care chemistries, critical care Leslie Cutter Number of Reagent Containers Consolidates chemistry and
chemistries, urine chemistries, esoteric Product Manager Onboard/Tests/Container: immunoassay testing on a single
chemistries, CSF chemistries, protein/ Telephone: (714) 993-8432 24 cartridges/300 tests per cartridge platform; parallel processing technology
serology, TDMs, DATs and thyroids Fax: (714) 961-3825 Reagents Refrigerated Onboard: allows both immunoassay and chemistry
Throughput: lccutter@beckman.com 15 degrees, cooled reagent compartment testing to be performed simultaneously;
DxC 800: 1,440 tests/hour; www.beckmancoulter.com closed-tube sampling for chemistry
Walkaway Capacity in
DxC 600: 990 tests/hour Primary Product: tests allows lab technologists to load
Specimen/Tests Assays:
Time to First Result: IMMAGE 800® Immunochemistry System sample tubes on the instrument without
Continuous loading, diluent
Stat analysis in less than one Methodologies Used: decapping them, which improves
capacity for 1,440 tests
minute; analyze 11 critical care efficiency and helps reduce exposure
Rate Nephelometry, Rate Inhibition System Liquid or Dry:
chemistries in 42 seconds to biohazards and repetitive motion
Nephelometry, Rate Near Infrared Liquid
Sample Size: injuries; closed-tube aliquotting, in which
Particle Immunoassay (NIPIA), Rate Average Length of System Startup
3-69 mL the instrument automatically makes a
NIPIA Inhibition. Gold Standard in Protein Time and Daily Maintenance:
Frequency of Calibration: daughter tube from a primary tube for
testing. Rate Nephelometry methods <1 minute
Varies immunoassay testing; serum indices and
collect hundreds of datapoint readings Contact:
Integrated Data Management: clot detection features improved integrity
for each assay being measured to Mark Watanabe
Yes of patient test results; data management
ensure accurate, reliable results. Product Manager
Open Reagent System: system allows technologists to program
Tests Available in the U.S.: Telephone: (714) 961-3779
Yes chemistry and immunoassay tests
IgG, Urine IgG, IgA, IgM, IgALC, IgMLC, Fax: (714) 961-3825
Primary Tube Sampling: from a single computer interface
Kappa, Lambda, C3, C4, RF, ASO, mswatanabe@beckman.com
Yes Operational Type:
CRP, hsCRP, Haptoglobin, Beta 2 www.beckmancoulter.com
Positive Sample ID: Microglobulin*, IgE, Albumin, Prealbumin, Continuous random access,
Yes Primary Product:
Ferritin, Transferrin, Apolipoprotein batch and stat
Onboard Dilution: UniCel® DxC 600i
A1, Apolipoprotein B, Lipoprotein (a), Separation Methodologies:
Yes Type of Analyzer:
Microalbumin, Alpha1 Microglobulin, Centrifugation, homogenous
Other Utility Requirements: Alpha 1 Acid Glycoprotein, Cerluoplasmin, Chemistry/immunoassay/data
Sample Handling System:
Deionized water Alpha 1 Antitrypsin, Alpha 2 management/automation system
Rack
What differentiates your product from Macroglobulin, Properdin Factor B, DNB, Methodologies Used:
Number of Reagent Containers
other products on the market? Antithrombin, Digoxin, Carbamazepine, Near-infrared particle immuno, Onboard/Tests/Container:
Closed-tube sampling technology; Phenytoin, Phenobarbital, Valproic Acid, turbidimetric, ISE, conductivity, oxygen 89 onboard reagents; 25-400 tests
ability to analyze 11 critical care Gentamicin, Tobramycin, free Kappa sensor, photometric, chemiluminescent per container (photometric); up to
chemistries in just 42 seconds; Light chains*, free Lambda chains*, Tests Available in the U.S.: 3,200 tests per container (modular)
proactive remote diagnostics (weekly IgG subclasses*. Note: * UDR assay Approximately 150 tests. Immunoassay: Reagents Refrigerated Onboard:
analysis of instrument trends to Throughput: thyroid, fertility, anemia, cardiovascular, Yes
prevent technical problems from 180 tests/hour adrenal/pituitary, specialty, tumor Walkaway Capacity in
occurring); centrifugable racks; clot Time to First Result: markers, infectious disease and Specimen/Tests Assays:
detection; serum indices; automation 6.5 minutes skeletal tests; Chemistry: general, One hour
connectability; continuous autoloader; Sample Size: critical care, urine, esoteric, System Liquid or Dry:
polychromatic correction; near infrared Assay dependent: 6-40 uL proteins/serologies, TDMs, DATs Liquid
s

92 | July 2007 • advance /Laboratory • www.advanceweb.com


« laboratory analyzers buyers guide »
Average Length of System Startup Gentamycin, Tobramycin, Vancomycin. System Liquid or Dry: Theophylline, Thyronine Uptake,
Time and Daily Maintenance: ANTIARRYTHMICS: Digoxin, digitoxin, Liquid Thyroxine, Tobramycin, Total Bilirubin,
None N-Acetylprocainamide, Lidocaine, Average Length of System Startup Total Iron Binding Capacity, Total
Procainamide. TDM: Carbamazepine, Time and Daily Maintenance: Protein, Transferrin, Triglyceride,
Dade Behring cyclosporine, cyclosporine extended 7 minutes Triiodothyronine, Uric Acid, Urinary/
1717 Deerfield Rd. range, lithium, phenobarbital, phenytoin, Cerebrospinal Fluid Protein, Urine
Contact:
Deerfield, IL 60015 tacrolimus, sirolimus*, theophylline, Amphetamine, Urine Barbiturates,
Stephanie Antenucci
Contact: valproic acid. IMMUNOLOGY: Urine Benzodiazepines, Urine Cocaine,
Marketing Communications Manager
William Swain Complement C3, Complement C4, C- Urine Ecstasy, Urine Methadone, Urine
Telephone: (302) 631-0442
Marketing Communications Manager Reactive protein, C-Reactive protein Methaqualone*, Urine Opiate, Urine
Fax: (302) 631-8511 Phencyclidine, Urine Propoxyphene*
Telephone: (302) 631-0456 extended range, IgA, IgG, IgM,
antenusn@dadebehring.com (*Syva®Emit® applications)
Fax: (302) 631-8511 Transferrin. SPECIALTY: Ammonia,
www.dadebehring.com Throughput:
william_swain@dadebehring.com Urine/Cerebrospinal fluid protein,
Primary Product: Up to 1500 tests/hour
www.dadebehring.com Lactic acid, prealbumin, HCG, ferritin.
Dimension Vista® Intelligent Lab System Time to First Result:
Primary Product: PROSTATE CANCER: Total PSA,
Dimension® RxL Max® Integrated free PSA. (*under development) Methodologies Used: Varies by method: 22
Chemistry Analyzer Throughput: Photometry, potentiometry (ISE), seconds to 17 minutes
Type of Analyzer: 788 tests/hour advance LOCI® chemiluminescence Sample Size:
Chemistry/Immunochemistry Time to First Result: technology, nephelometry, EMIT®, 1-20 µL
60 seconds PETINIA, PETIA, ACMIA, turbidimetric Frequency of Calibration:
Methodologies Used:
Sample Size: Tests Available in the U.S.: Autocalibration, 30-90 days,
Photometry, potentiometry, integrated 5, 7 and 10 mL primary tubes
multisensor technology (IMT), a1Acid Glycoprotein (Orosomucoid), varies by method
Frequency of Calibration:
heterogeneous EIA using HM, EMIT® latex a1Antitrypsin, a1Microglobulin, Integrated Data Management:
30-90 days
particle turbidimetric, latex turbidimetric Acetaminophen, Alanine Transaminase, Yes
Integrated Data Management:
Tests Available in the U.S.: Albumin, Alkaline Phosphatase, Open Reagent System:
Yes
Ammonia, Amylase, Antistreptolysin Yes
GENERAL CHEMISTRY: Albumin, BUN, Open Reagent System:
O, Apolipoprotein A1, Apolipoprotein Primary Tube Sampling:
Calcium, Creatinine, Direct Bilirubin, Yes
B, Aspartate Transaminase, Yes
Enzymatic C02, Iron, Magnesium, Primary Tube Sampling:
ß2Microglobulin, Blood Urea Nitrogen, Positive Sample ID:
Phosphorus, Total Bilirubin, TIBC, Yes
C Reactive Protein, C3 Complement, C4 Yes
IBCT (no pretreat), Total Protein, Urea Positive Sample ID: Complement, Calcium, Carbamazepine, Onboard Dilution:
Nitrogen, Uric Acid. ELECTROLYTES: Yes Carbon Dioxide, Ceruloplasmin,
Carbon Dioxide, Chrloride, Potassium, Yes
Onboard Dilution: Chloride, Cholesterol, Creatine Kinase,
Sodium. Enxymes: Acid Phosphatase, What differentiates your product from
Yes Creatine Kinase MB Isoenzyme,
Alanine Aminotransferase, Alkaline other products on the market?
Other Utility Requirements: Creatinine, Cyclosporine, Cystatin C,
Phosphatase, Amylase, Aspartate The first intelligent lab system to
Deionized water NCCLS Type 2 Digitoxin, Digoxin, Direct Bilirubin,
Aminotransferase, CK, CKMB Isoenzyme, combine 4 best-in-class technologies
What differentiates your product from Ethyl Alcohol, Gamma Glutamyl
GT, Lactic Dehydrogenase, Lipase, in one workstation: photometry,
other products on the market? Transaminase, Gentamicin, Glucose,
Pseudocholinesterase. DIABETES nephelometry, V-LYTE® electrolyte
Integrates heterogeneous immunoassays Haptoglobin, Hemoglobin A1C, High
MANAGEMENT: HA1c, Glucose (liquid), detection and LOCI® advanced
onboard with other chemistries; Density Lipoprotein Cholesterol, High
microalbumin. CARDIAC EVENT: chemiluminescence. These 4 concurrent
allows single platform for over 95 Sensitivity CRP (CardioPhase® hsCRP),
cTnI, mass CKMB, Myoglobini, NT- detection systems provide accurate
percent of most requested tests; Homocysteine, Immunoglobulin E,
proBNP. CARDIAC RISK ASSESSMENT: results you can trust, while simplifying/
eliminates sample splitting between Immunoglobulin A, Immunoglobulin
CardioPhase hsCRP, Cholesterol, HDL, consolidating sample processing, which
general tests and immunoassays G, Immunoglobulin M, Iron, Lactate
AHDL cholesterol, ALDL cholesterol, minimizes TAT and sample requirements.
Operational Type: Dehydrogenase, Lactic Acid, Lidocaine,
triglycerides. THYROID: TSH, TU, Total Operational Type:
Batch, random access, Lipase, Lithium, LOCI® Beta Human
Thyroxine/Total T4, Free Thyroxine/ Chorionic Gondatropin, LOCI® Cardiac Batch, random access, continuous
continuous random access
Free T4, Triiodothyronine. DRUGS-OF- Troponin I, LOCI® Ferritin, LOCI® Free random access/self-contained multi-
Separation Methodologies:
ABUSE: Serum barbiturates, serum Thyroxine, LOCI® Free Triiodothyronine, use cartridges-packages sample rack
EIA, latex particle turbidimetric,
benzodiazepines, serum tricyclic LOCI® Mass Creatine Kinase MB and aliquot plate system/floor standing
direct turbidimetric/heterogeneous,
antidepressants, urine amphetamine Isoenzyme, LOCI® Myoglobin, LOCI® N Sample Handling System:
magnetic particles
screen, urine barbiturates screen, terminal proBrain natriuretic peptide, Sample rack handles variety of
Sample Handling System:
urine benzodiazepines screen, urine LOCI® Thyroid Stimulating Hormone, primary tubes and cups. Aliquot
Segmented sample wheel
cannabinoids screen, urine cocaine Low Density Lipoprotein Cholesterol, plate allows samples to remain
Number of Reagent Containers available onboard for up to 2 hours.
metabolite screen, urine ecstasy, urine Magnesium, Microalbumin, Nacetyl
Onboard/Tests/Container:
methadone screen, urine methaqualone Procainamide, Phenobarbital, Phenytoin, Number of Reagent Containers
screen*, urine opiates screen, urine 88 with optional reagent management Onboard/Tests/Container:
Phosphorus, Potassium, Prealbumin
propoxyphene screen*. TOXICOLOGY: system/maximum 360 Flex® cartridges calibrators and QC can
(Transthyretin), Procainamide,
Acetaminophen, ethyl alcohol, Reagents Refrigerated Onboard: Pseudocholinesterase, Rheumatoid remain onboard available for use in the
salicylate, serum barbiturates*, serum Yes Factor, Serum Barbiturates*, Serum 166 slots. Tests per container varies
benzodiazepines*, serum tricyclic Walkaway Capacity in Benzodiazepines*, Serum Salicylate, by method 20-1,200 tests per Flex®
antidepressants*, urine methaqualone Specimen/Tests Assays: Serum Tricyclic Antidepressants*, Reagents Refrigerated Onboard:
screen*. ANTIMICROBIALS: Yes (can be hours) Sodium, Soluble Transferrin Receptor, Yes
s

94 | July 2007 • advance /Laboratory • www.advanceweb.com


« laboratory analyzers buyers guide »
Walkaway Capacity in QC and reagent packs; tankless gas Other Utility Requirements: Albumin Alcohol Alkaline Phosphatase
Specimen/Tests Assays: calibration; automated maintenance Deionized water, drain ALT Ammonia Amylase AST BuBc
600-800 specimens Operational Type: What differentiates your product from Bilirubin BUN/Urea Calcium
System Liquid or Dry: Individual sample other products on the market? Carbamazepine Carbon Dioxide Chloride
Liquid, ready to use Sample Handling System: Olympus Standardization meets Cholesterol Cholinesterase CK CK-MB
Average Length of System Startup Dock for syringe or capillary sample laboratories’ workflow needs with CRP Creatinine (Enzymatic) CSF Protein
Time and Daily Maintenance: Number of Reagent Containers four chemistry-immuno analyzers Digoxin GGT Glucose Iron Lactate LDH
3 minutes standardized for greater efficiency Lipase Lithium Magnesium Phenobarbital
Onboard/Tests/Container:
for the hospital core lab, satellite lab, Phenytoin Phosphorus Potassium
Two—one reagent container for ABG/
Nova Biomedical outpatient lab, single and multiple Salicylate Sodium Theophylline Total
chemistry and one for co-oximeter/2,600
locations, with throughput speeds from
200 Prospect St. to 6,500 tests per container depending Bilirubin Total Protein Triglycerides TIBC
400–6,600 tests per hour. Olympus
Waltham, MA 02454 on laboratory use pattern Uric Acid Urine Protein Expanded Menu
125 Test Menu streamlines workflow
Contact: Reagents Refrigerated Onboard: AAT AmphetaminesU Apo A1 Apo B
by consolidating testing with fewer
Harlan Polishook No ASO BarbituratesU BenzodiazepinesU
workstations, faster TAT and greater
Marketing Communications Manager System Liquid or Dry: C3 C4 Caffeine CannabinoidsU Cocaine
capacity. Lab automation reduces
Telephone: (781) 894-0800 Liquid/ISE sample handling labor and errors while MetabolitesU d%A1c dHDL (MicroSlide
Fax: (781) 894-5915 improving turnaround time. Service format) dLDL dTIBC Gentamicin
Average Length of System Startup
info@novabiomedical.com Time and Daily Maintenance: and support provides comprehensive Haptoglobin Homocysteine hsCRP IgA
www.novabiomedical.com <5 minutes customer-tailored solutions to increase IgG IgM MethadoneU Microalbumin
Primary Product: productivity and ensure maximum OpiatesU PhencyclidineU Prealbumin
Stat Profile Critical Care Xpress system uptime with reliable results. Rheumatoid Factor Tobramycin
Olympus America Inc.
Type of Analyzer: Operational Type: Transferrin Valproic Acid Vancomycin
3500 Corporate Parkway
Blood gas/electrolyte/chemistry Fully selective discrete, random access 10 user-defined channels (U-Urine)
Center Valley, PA 18034
Methodologies Used: Separation Methodologies: Throughput:
Contact:
Ion selective electrode/ Homogeneous Text mix dependent
Frank Bartholf
optical, reflectance Sample Handling System: Time to First Result:
Senior Product Manager
Tests Available in the U.S.: Rack and 22-position stat carousel 3 minutes
Telephone: (800) 223-0125
pH, PCO2, PO2, hematocrit, hemoglobin, Number of Reagent Containers Sample Size:
Fax: (484) 896-7131
sodium, potassium, chloride, ionized Onboard/Tests/Container: 2-17 uL
olympusdsg@olympus.com
calcium, ionized magnesium, glucose, 76-96 onboard reagent cartridges Frequency of Calibration:
www.olympusamerica.com
BUN, creatinine, lactate, bilirubin, (model dependent); 50-4,000 tests Up to 6 months calibration
Primary Product:
deoxyhemoglobin, oxyhemoglobin, per cartridge (test dependent) Integrated Data Management:
Olympus AU chemistry-immuno systems
methemoglobin, carboxyhemoglobin Reagents Refrigerated Onboard?: Yes
Type of Analyzer:
Throughput: Yes Open Reagent System:
Chemistry-immuno analyzers
21-26 samples/hour Walkaway Capacity in Yes
Methodologies Used:
Time to First Result: Specimen/Tests Assays: Primary Tube Sampling:
Endpoint, potentiometric,
65 seconds (normal throughput); 140 6,500 to 65,000 tests, model dependent Yes
kinetic rate and fixed rate
seconds (alternate throughput) System Liquid or Dry: Positive Sample ID:
Tests Available in the U.S.:
Sample Size: Liquid Yes
125-test menu including general, stat
60-210 mL Average Length of System Startup Onboard Dilution:
and urine chemistries, serum proteins,
Frequency of Calibration: Time and Daily Maintenance: Yes
therapeutic and drug of abuse assays
Automatic 5 minutes What differentiates your product from
Throughput:
Integrated Data Management: other products on the market?
400-6,600 tests per hour, Ortho-Clinical Diagnostics
Yes No water, drains, fixed probes or mixing
model dependent 1001 US Highway 202
Open Reagent System: assemblies required. Calibration stability
Time to First Result: Raritan, NJ 08869 up to lot change. Wide accessible
No
2–9 minutes depending on analyzer and Contact: menu with 125 reagent positions
Primary Tube Sampling:
mode of operation such as stat or routine Greg Winther on board. Eliminates the additional
Yes
Sample Size: Marketing Manager cost, maintenance, carry-over and
Positive Sample ID:
1-20 mL, test dependent Telephone: (908) 218-8116 contamination risks associated with
Yes
Onboard Dilution: Frequency of Calibration: Fax: (908) 704-6837 traditional water-based systems.
Yes 30 days (median) gwinther@ocdus.jnj.com Intelligent Parallel Processing
What differentiates your product from Integrated Data Management: www.orthoclinical.com integrating MicroSlideT and MicroTipT
other products on the market? Yes Primary Product: Technologies. Automated capping/
Comprehensive 20-test critical care Open Reagent System: VITROS 5,1 FS Chemistry System decapping of MicroTip reagents.
profile, including ionized magnesium, Yes Type of Analyzer: User-defined assay capability.
BUN, creatinine, and bilirubin; Primary Tube Sampling: Chemistry Operational Type:
integrated co-oximetry; color touch Yes Methodologies Used: Continuous random access
screen, open software architecture, Positive Sample ID: Colorimetric, Immunorate, Separation Methodologies:
onboard data management; automate, Yes Potentiometric, Turbidimetric Homogenous
onboard quality control; sealed Onboard Dilution: Tests Available in the U.S.: Sample Handling System:
waste system; auto-monitoring of Yes Acetaminophen Acid Phosphatase Universal sample tray
s

96 | July 2007 • advance /Laboratory • www.advanceweb.com


« laboratory analyzers buyers guide »
Number of Reagent Containers Gentamicin Lithium Phenobarbital and immunologic testing and uncapped), sample cups; ACL
Onboard/Tests/Container: Phenytoin Theophylline Tobramycin Tests Available in the U.S.: Advance: Primary tubes and sample
125 reagent positions; up Valproic Acid Vancomycin Recombinant PT, APTT, TT, Fibrinogen, cups; ACL Elite and Elite Pro: Primary
to 100 tests/container Throughput: D-Dimer/D-Dimer HS, VWF, Protein tubes and sample cups; ACL 1000 and
Reagents Refrigerated Onboard: 1,800 tests/hour C, Protein S, Free Protein S, APCR- 7000: Primary tubes and sample cups
Yes Time to First Result: V Leiden, AT, Heparin, Plasminogen, Number of Reagent Containers
Walkaway Capacity in 10 minutes Plasmin Inhibitor, Lupus Anticoagulant, Onboard/Tests/Container:
Specimen/Tests Assays: Sample Size: Factor Assays, Factor XIII ACL TOP Series: 60/varies by test;
160 specimens/8,940 tests 2-30 mL Throughput: ACL Advance: 42/varies by test; ACL
System Liquid or Dry: Frequency of Calibration: ACL TOP Series: up to 360/hr; ACL Elite Pro: 22/varies by test; ACL Elite:
Dry and liquid (no water Up to 60 days Advance: 240/hr; Elite and Elite Pro: 18/varies by test; ACL 7000: 4/varies
systems required) Open Reagent System: 175/hr; ACL 7000/1000: up to 110/hr by test; ACL 1000: 3/varies by test
Average Length of System Startup Yes Time to First Result: Reagents Refrigerated Onboard:
Time and Daily Maintenance: Primary Tube Sampling: ACL TOP Series: <3 min; ACL Advance: Yes, 15°C
Immediate startup; 10 minutes 2.5 min; ACL Elite and Elite Pro 4 Walkaway Capacity in
Yes
daily maintenance min; ACL 7000/1000: 5.5 min Specimen/Tests Assays:
Positive Sample ID:
Yes Sample Size: ACL TOP Series: 120/800; ACL Advance:
Siemens Medical Solutions Diagnostics ACL TOP Series: 50 µL; ACL Advance: 120/264; ACL Elite and Elite Pro:
What differentiates your product from
511 Benedict Ave. 50 µL; ACL Elite and Elite Pro: 60 40/260; ACL 7000/1000: 18/20
other products on the market?
Tarrytown, NY 10591 µL; ACL 7000/1000: 50 µL System Liquid or Dry:
Automation ready; highest productivity
Contact: Frequency of Calibration: Liquid
synergy with other ADVIA family of
Tina Johne Varies by test Average Length of System Startup
systems; reliability; commitment
Head Global Communications Integrated Data Management: Time and Daily Maintenance:
to investment in future
Telephone: (914) 524-2429 Yes 10 minutes
Operational Type:
Fax: (914) 524-3693 Open Reagent System:
Continuous random access
tina.johne@siemens.com Yes Primary Product:
Separation Methodologies:
http://diagnostics.siemens.com Primary Tube Sampling: ACL Top Series (with cap
Universal rack handler with up to
Primary Product: Yes piercing capability)
2,400 samples/Track automation
ADVIA 1800 System Positive Sample ID: Type of Analyzer:
with unlimited samples
Methodologies Used: Yes Coagulation, hemostasis
Sample Handling System:
End-point, Rate, 2- Point Date, ISE Onboard Dilution: Methodologies Used:
55 test onboard capacity including ISE
Tests Available in the U.S.: Yes LED (optical) clot detection,
Number of Reagent Containers
Acid Phosphatase Alanine What differentiates your product from chromogenic, immunologic
Onboard/Tests/Container:
Aminotransferase Alanine other products on the market? Tests Available in the U.S.:
55 test onboard capacity including ISE
Aminotransferase (P5P) Albumin Alkaline ACL TOP Series: state-of-the-art Recombinant PT, APTT, TT, Fibrinogen,
Reagents Refrigerated Onboard: D-Dimer/D-Dimer HS, VWF, Protein C,
Phosphatase AMP Alkaline Phosphatase technology featuring clot signature
Yes Protein S, APCR-V Leiden, AT, Heparin,
DEA Amylase Aspartate Aminotransferase curve analysis and closed tube
Walkaway Capacity in Plasminogen, Plasmin Inhibitor, Lupus
Aspartate Aminotransferase (P5P) sampling; robust system offering
Specimen/Tests Assays: Anticoagulant, Factor Assays, Factor XIII
Bilirubin-Direct Bilirubin-Total Calcium continuous operation without interruption
Yes. Auto-dilution, auto-replex Throughput:
Carbon Dioxide Cholesterol Chloride to workflow; minimized operator
testing and auto-repeat Up to 360 PTs/hour
Creatine Kinase Creatinine Creatinine, intervention using intuitive Windows
Average Length of System Startup Time to First Result:
Enzyme Direct LDL Cholesterol 2000 Professional software; 2D bar
Time and Daily Maintenance: PT< 3 min
Gamma-Glutamyltransferase Glucose- code for reagent, calibration and
5 minutes Sample Size:
Hexokinase Glucose-Oxidase D-HDL control value import. ACL Advance:
Inorganic Phosphorus Iron Lactate# extensive menu of clotting, chromogenic PT - 50 uL
Lactate Dehydrogenase L-P Lactate • Coagulation and immunologic assays; high-end Frequency of Calibration:
Dehydrogenase P-L Lipase Magnesium capabilities/small footprint; LED optics, Varies by assay
Potassium Sodium TIBC Total Protein Beckman Coulter Inc. providing optimized results regardless Integrated Data Management:
Triglycerides Urea Nitrogen Uric Acid 200 S. Kraemer Blvd. of pre-analytical variables. ACL Elite Yes
Urinary Protein Alpha-1 Antitrypsin Brea, CA 92822 and Elite Pro: test menu featuring D- Open Reagent System:
Anti-Streptolysin O Apolipoprotein Contact: dimer, barcode reagent management, Yes
A1 Apolipoprotein B C3 C4 CRP CRP- Venita Shirley ACL family harmonization. ACL 1000 and Primary Tube Sampling:
Wide Range Haptoglobin IgA IgG Marketing Manager 7000: positive displacement pipetting Yes
IgM Rheumatoid Factor Transferrin Telephone: (714) 993-8687 for low maintenance and high precision Positive Sample ID:
Acetaminophen Amphetamines Fax: (714) 961-3825 Operational Type: Yes
Barbiturates Benzodiazepines vcshirley@beckman.com ACL TOP Series: continuous random Onboard Dilution:
Cannabinoids Cocaine Metabolite Ethanol www.beckmancoulter.com access; ACL Advantage: random Yes
Methadone Opiates Phencyclidine Primary Product: access; ACL Elite and Elite Pro: What differentiates your product from
Propoxyphene Salicylate Ammonia# ACLT TOP Series, ACLT Advance, ACLT modified random access; ACL 1000 other products on the market?
Cholinesterase HbA1c (whole blood) Elite and Elite Pro, ACLT 1000 and 7000 and 7000: random programming State-of-the-art technology featuring
Microalbumin Pancreatic Amylase Methodologies Used: Sample Handling System: clot signature curve analysis and
s

Prealbumin Carbamazepine Digoxin LED (optical) clot detection, chromogenic ACL TOP Series: Primary tubes (capped closed tube sampling; robust system

98 | July 2007 • advance /Laboratory • www.advanceweb.com


« laboratory analyzers buyers guide »
offering continuous operation Integrated Data Management: if laboratory determines QC is recommend calibration at least
without interruption to workflow; Yes outside of the acceptable range or once every six months. More
minimized operator intervention using Open Reagent System: as dictated by local regulations. frequent calibration may be required
intuitive Windows 2000 Professional Yes Integrated Data Management: if laboratory determines QC is
software; 2D bar code for reagent, Primary Tube Sampling: Yes outside of the acceptable range or
calibration and control value import Yes Open Reagent System: as dictated by local regulations.
Operational Type: Positive Sample ID: Yes Integrated Data Management:
Continuous random access No Primary Tube Sampling: Yes
Sample Handling System: Onboard Dilution: Yes Open Reagent System:
Primary tubes (capped and Yes Positive Sample ID: Yes
uncapped) and sample cups Other Utility Requirements: Yes Primary Tube Sampling:
Number of Reagent Containers Deionized water Onboard Dilution: Yes
Onboard/Tests/Container: What differentiates your product from Yes Positive Sample ID:
Up to 60 reagents onboard/ other products on the market? Other utility requirements: Yes
varies with assay 5-parameter true random access Deionized water required, container Onboard Dilution:
Reagents Refrigerated Onboard: clotting/chromogenic; standard or direct plumbed option Yes
Yes, 44 reagents in cap piercing; small footprint; What differentiates your product from Other Utility Requirements:
Walkaway Capacity in complete automation; specialty assay other products on the market? Deionized water required, container
Specimen/Tests Assays: capability; low operating expense Simultaneous curve calibrating and or direct plumbed option
120 continuous loading walkaway Operational Type: patient testing; standard in cap What differentiates your product from
capacity/up to 30 tests per sample Continuous random access piercing; ability to load multiple other products on the market?
System Liquid or Dry: Sample Handling System: bottles or multiple lots of reagents Fastest throughput available for routine
Liquid Rack Operational Type: testing; standard in cap-piecing; PT, APTT
Average Length of System Startup Number of Reagent Containers Continuous random access results every 7 seconds; continuous
and Daily Maintenance: Onboard/Tests/Container: Sample Handling System: loading of reagents, consumables and
<10 minutes 11 containers/tests vary Rack patient samples without interruption
Reagents Refrigerated Onboard: Number of Reagent Containers Operational Type:
Dade Behring Yes Onboard/Tests/Container: Continuous random access
1717 Deerfield Rd. Walkaway Capacity in 39 containers/tests vary Sample Handling System:
Deerfield, IL 60015 Specimen/Tests Assays: Reagents Refrigerated Onboard: Rack
Contact: 10 specimens/assays vary Yes Number of Reagent Containers
Amy Boyett System Liquid or Dry: Walkaway Capacity in Onboard/Tests/Container:
Senior Communications Specialist Liquid Specimen/Tests Assays: 58 containers/tests vary
Telephone: (847) 267-5300 Average Length of System Startup 50 specimens/assays vary Reagents Refrigerated Onboard:
Fax: (847) 236-7101 Time and Daily Maintenance: System Liquid or Dry: Yes
amy_boyett@dadebehring.com Daily maintenance < 5 minutes Liquid Walkaway Capacity in
www.dadebehring.com Average Length of System Startup Specimen/Tests Assays:
Primary Product: Primary Product: Time and Daily Maintenance: 100 specimens/assays vary
Sysmex® CA-530 Coagulation Analyzer Sysmex® CA-1500 Coagulation Analyzer Daily maintenance < 5 minutes System Liquid or Dry:
Type of Analyzer: Methodologies Used: Primary Product: Liquid
Coagulation Optical based system. Clotting, Sysmex® CA-7000 Coagulation Analyzer Average Length of System Startup
Methodologies Used: chromogenic and immunologic Methodologies Used: Time and Daily Maintenance:
Optical based system. Clotting and methodologies used Optical based system, clotting, Daily maintenance: <5 minutes
chromogenic methodologies used Tests Available in the U.S.: chromogenic and immunologic
Tests Available in the U.S.: PT, APTT, Fibrinogen, TT, Reptilase methodologies used Primary Product:
BCS® XP System
PT, APTT, Fibrinogen, TT, Factor time, Factor Assays, drVVt screen and Tests Available in the U.S.:
Assays, Reptilase time, Protein C clot, confirm, Factor V Leiden, Protein C clot, Methodologies Used:
PT, APTT, Fibrinogen, TT, Reptilase
Optical based system. Clotting,
AT III, Protein C chromo, heparin Protein S activity, AT III, Plasminogen, time, Factor Assays, drVVt screen and
chromogenic and immunologic
Throughput: Factor VIII chromo, Alpha-2 Antiplasmin, confirm, Factor V Leiden, Protein C clot,
Tests Available in the U.S.:
54 PT tests/hour, 43 PT/APTT tests/hour Protein C chromo, Heparin, D-Dimer Protein S activity, AT III, Plasminogen,
PT, APTT, Fibrinogen, TT, Reptilase time,
Time to First Result: Throughput: Factor VIII chromo, Alpha-2 Antiplasmin,
Factor Assays, drVVt screen and confirm,
7 minutes 120 PT tests/hour, 80 PT/APTT tests/hour Protein C chromo, Heparin, D-Dimer
Factor V Leiden, Protein C clot, Protein
Sample Size: Time to First Result: Throughput: S activity, AT III, Plasminogen, Factor VIII
50 µL PT, 100 µL APTT 7 minutes 280 PT tests/hour, 480 PT/ chromo, Alpha-2 Antiplasmin, Protein C
Frequency of Calibration: Sample Size: APTT tests/hour chromo, Heparin, Advanced D-Dimer, BC
Assay dependent. CLIA guidelines 50 µL PT, 100 µL APTT Time to First Result: von Willebrand-risto. Cofactor assay
recommend calibration at least once Frequency of Calibration: 7 minutes Throughput:
every six months. More frequent Assay dependent. CLIA guidelines Sample Size: 380 PT tests/hour; 325 PT/
calibration may be required if lab recommend calibration at least 50 µL PT, 100 µL APTT APTT tests/hour
determines QC is outside the acceptable once every six months. More Frequency of Calibration: Time to First Result:
range or as dictated by local regulations. frequent calibration may be required Assay dependent. CLIA guidelines <5 minutes
s

100 | July 2007 • advance /Laboratory • www.advanceweb.com


« laboratory analyzers buyers guide »
Sample Size: once every six months. More factor assays, vWF, free Protein S, Time to First Result:
50 µL PT, 100 µL APTT frequent calibration may be required reptilase, Protein C & S, heparin <5 minutes
Frequency of Calibration: if laboratory determines QC is (LMWH & UFH), AT, plasminogen, Sample Size:
Assay dependent. CLIA guidelines outside of the acceptable range or antiplasmin. Numerous assays are from 5 uL
recommend calibration at least as dictated by local regulations. also available for research testing. Frequency of Calibration:
once every six months. Integrated Data Management: Throughput: Varies with assay
Integrated Data Management: Yes 150 PTs/hour Integrated Data Management:
Yes Open Reagent System: Time to First Result: Yes
Open Reagent System: Yes <5 minutes Open Reagent System:
Yes Primary Tube Sampling: Sample Size: Yes
Primary Tube Sampling: Yes From 5 uL Primary Tube Sampling:
Yes Frequency of Calibration: Yes
Positive Sample ID:
Positive Sample ID: Varies with Assay Positive Sample ID:
Yes
Yes Integrated Data Management: Yes
Onboard Dilution:
Onboard Dilution: Yes Onboard Dilution:
Yes
Yes Open Reagent System: Yes
Other Utility Requirements:
Other Utility Requirement: Yes What differentiates your product from
Deionized water required
Deionized water Primary Tube Sampling: other products on the market?
What differentiates your product from Total Lab Automation capable,
What differentiates your product from Yes
other products on the market? mechanical clot detection using
other products on the market? Positive Sample ID:
Smallest footprint in its class; standard VDS (Viscosity-based Detection
User-definable calibration curve Yes
expiration and pre-warning alerts; in cap-piecing; onboard quality control System), standardization among
package; primary tube sampling Onboard Dilution:
user-definable barcode utility enables all equipment in the Stago product
and removable reagent trays Yes line, cap-piercing option
customizable reagent protocols; user-
Operational Type: What differentiates your product from Operational Type:
friendly Windows XP software
other products on the market?
Operational Type: Continuous random access Continuous random access
Barcoded reagents throughout product
Continuous random access Sample Handling System: Sample Handling System:
line; mechanical detection system;
Sample Handling System: Rack 240 samples
standardized results throughout product
Rack Number of Reagent Containers Number of Reagent Containers
line; reliable hardware; connectivity
Number of Reagent Containers Onboard/Tests/Container: Onboard/Tests/Container:
to total lab automation systems
Onboard/Tests/Container: 11 containers/tests vary 70 reagents/varies with assay
Operational Type:
90 containers/tests vary Reagents Refrigerated Onboard: Reagents Refrigerated Onboard:
Continuous random access
Reagents Refrigerated Onboard: Yes Yes
Sample Handling System:
Yes Walkaway Capacity in Walkaway Capacity in
96 samples
Walkaway Capacity in Specimen/Tests Assays: Specimen/Tests Assays:
Number of Reagent Containers 200 test set-ups
Specimen/Tests Assays: 10 specimens/assays vary
Onboard/Tests/Container:
100 specimens/assays vary System Liquid or Dry: System Liquid or Dry:
45 reagents/varies with assay
System Liquid or Dry: Liquid Liquid
Reagents Refrigerated Onboard:
Liquid Average Length of System Startup Average Length of System Startup
Yes
Time and Daily Maintenance: Time and Daily Maintenance:
Average Length of System Startup Walkaway Capacity in
Daily maintenance: <5 minutes <5 minutes, no daily maintenance
Time and Daily Maintenance: Specimen/Tests Assays:
Daily maintenance: <5 minutes
Diagnostica Stago
Varies with model
System Liquid or Dry:
• Drug Testing
5 Century Dr.
Primary Product: Liquid
Parsippany, NJ 07054 Dade Behring
Sysmex® CA-560 Coagulation Analyzer Average Length of System Startup
Contact: 1717 Deerfield Rd.
Methodologies Used: Time and Daily Maintenance:
Anna Pambianchi Deerfield, IL 60015
Optical based system. Clotting, No daily maintenance
Marketing Communications Specialist Contact:
chromogenic and immunologic
Telephone: (973) 631-1200 Greg Apps
Tests Available in the U.S.: Primary Product:
Fax: (973) 631-1618 Marketing Communications Specialist
PT, APTT, Fibrinogen, TT, Factor Assays, STA-R
anna.pambianchi@stago-us.com Telephone: (302) 631-9669
Reptilase time, Protein C clot, AT III, Methodologies Used:
www.stago-us.com Fax: (302) 631-8511
Protein C chromo, Heparin, D-Dimer Clotting, chromogenic, immunologic
Primary Product: www.dadebehring.com
Throughput: Tests Available in the U.S.:
STA Compact Primary Product:
PT, APTT, fibrinogen, D-dimer, thrombin
54 PT tests/hour; 43 PT/APTT tests/hour Methodologies Used: Viva-Jr.T Drug Testing System
time, Lupus AC, intrinsic and extrinsic
Time to First Result: Viscosity-based detection system Type of Analyzer:
faxtor assays, vWF, free Protein S,
7 minutes for clotting assays; photo-optical Drug Testing
reptilase, Protein C & S, heparin
Sample Size: methodology for chromogenic (LMWH & UFH), AT, plasminogen, Methodologies Used:
50 µL PT, 100 µL APTT and immunologic assays antiplasmin. Numerous assays are EMIT® drugs of abuse assays, validity
Frequency of Calibration: Tests Available in the U.S.: also available for research testing tests and serum tox assays
Assay dependent. CLIA guidelines PT, APTT, fibrinogen, D-dimer, thrombin Throughput: Tests Available in the U.S.:
recommend calibration at least time, Lupus A, intrinsic and extrinsic 300 PTs/hour Comprehensive DAT menu, adulteration
s

102 | July 2007 • advance /Laboratory • www.advanceweb.com


« laboratory analyzers buyers guide »
tests and serum tox assays 5diff CP / COULTER Ac•T 5diff AL Time to First Result: Methodologies Used:
Throughput: Methodologies Used: Less than 60 seconds Coulter Principle, Bio-Physical
66 EMIT® tests per hour Impedance, absorbance Sample Size: Flow Cytometry, VCS, New
Time to First Result: cytochemistry and volume (ACV) 18 mL Methylene Blue Reticulocyte
11-12 minutes Tests Available in the U.S.: Frequency of Calibration: Tests Available in the U.S.:
Sample Size: CBC, 5-part WBC differential Twice a year CBC, 5-part differential,
2-30 µL per test, programmable Throughput: Integrated Data Management: reticulocyte %, #, MRV, IRF
in steps of 0.1µL Up to 60 samples/hr or up to No Throughput:
Frequency of Calibration: 80 samples/hr for AL Open Reagent System: Up to 75 samples/hour
Once a week or when QC No Time to First Result:
Time to First Result:
falls out of range Primary Tube Sampling: 1 minute 30 seconds
~1 minute
Integrated Data Management: Yes
Sample Size: Sample Size:
Yes Positive Sample ID:
30-53 mL 185 uL automatic, 125 uL
Open Reagent System: Yes
Frequency of Calibration: manual, 50 uL pre-dilute
Yes Onboard Dilution:
Not specified Frequency of Calibration:
Primary Tube Sampling: Yes
Integrated Data Management: Not specified by time; according
Yes What differentiates your product from
Yes to regulatory requirements
Positive Sample ID: other products on the market?
Open Reagent System: Integrated Data Management:
Yes Closed vial sampling; automatic
No validation of quality control data Yes
Onboard Dilution:
Primary Tube Sampling: (high/low flagging); storage of Open Reagent System:
No
Yes up to 250 patient results No
Other Utility Requirements:
Distilled or deionized water Positive Sample ID: Operational Type: Primary Tube Sampling:
Yes Batch Yes
What differentiates your product from
other products on the market? Onboard Dilution: System Liquid or Dry: Positive Sample ID:
The Viva-JrT features EMIT® assays Yes Liquid Yes
for gold standard performance in a What differentiates your product from Average Length of System Startup Onboard Dilution:
true benchtop system, plus winTOX® other products on the market? Time and Daily Maintenance: Yes
Integrated Data Management system Low review rates; 5-part differential; Less than five minutes, zero What differentiates your product from
Operational Type: closed vial sampling (Ac•TT 5diff CP); routine daily maintenance\ other products on the market?
Semi-continuous random access auto repeat, random access, match Combination of technologies
Separation Methodologies: capabilities, autoloader (Ac•TT 5diff AL) Primary Product: and software
Homogenous Operational Type: COULTER® LH 1511 Hematology Operational Type:
Sample Handling System: Single sample; random access Automation System
Batch
Wheel Sample Handling System: Integrated Data Management:
Separation Methodologies:
None or seven tube size tube Yes
Number of Reagent Containers Homogenous, no separation
Onboard/Tests/Container: holders for CP and AL, 10 tube Open Reagent System:
Sample Handling System:
9 tests onboard racks, 10 rack autoloader for AL. No
Cassettes
Reagents Refrigerated Onboard: Number of Reagent Containers Primary Tube Sampling:
Number of Reagent Containers
Yes Onboard/Tests/Container: Yes
Onboard/Tests/Container:
Walkaway Capacity in Five/varies Positive Sample ID:
Four containers-tests vary
Specimen/Tests Assays: Reagents Refrigerated Onboard: Yes
according to daily volume
25 samples No Onboard Dilution:
Yes Reagents Refrigerated Onboard:
System Liquid or Dry: Walkaway Capacity in
Other Utility Requirements: No
Liquid Specimen/Tests Assays:
Air compressor Walkaway Capacity in
Average Length of System Startup N/A for open vial or CP,
What differentiates your product from Specimen/Tests Assays:
Time and Daily Maintenance: 100 tube/load for AL
other products on the market? Yes, continuous feed
<10 minutes System Liquid or Dry:
Completely automates the hematology System Liquid or Dry:
Liquid
• Hematology Average Length of System Startup
process for pre-analytical to
post-analytical processing
Liquid
Average Length of System Startup
Time and Daily Maintenance:
Operational Type: Time and Daily Maintenance:
Beckman Coulter Inc. Start-up less than five minutes;
Continuous random access Operator has one keystroke for
200 S. Kraemer Blvd. no routine daily maintenance
Sample Handling System: start up. Five minutes to start
Brea, CA 92822
Primary Product: Single tube up. No daily maintenance.
Contact:
COULTER® Ac•TT diff 2T Walkaway Capacity in
Mary Beth Johnson
Methodologies Used: Specimen/Tests Assays: Primary Product:
Marketing Manager
Impedance, COULTER Varies COULTER® LH 750 and COULTER
Telephone: (714) 993-8438
Fax: (714) 961-3675 histogram differential Average Length of System Startup LH 780 Hematology Systems
mbjohnson@beckman.com Tests Available in the U.S.: Time and Daily Maintenance: Methodologies Used:
www.beckmancoulter.com CBC, 3-part differential 15 minutes AccuCount technology combined
Primary Product: Throughput: Primary Product: with the Coulter impedance, flow
s

COULTER® Ac•TT 5diff / COULTER Ac•T Up to 60 samples/hour COULTER® LH 500 cytometry; VCS differential technology.

Circle 79 on FREE Information Card


104 | July 2007 • advance /Laboratory • www.advanceweb.com
« laboratory analyzers buyers guide »
Tests Available in the U.S.: productsusa@drew-scientific.com ray.xiang@mindray.com
CBC, 5-part WBC differential, www.drew-scientific.com www.mindray.com • Immunoassay
reticulocytes, NRBCs Primary Product: Primary Product: Bayer HealthCare Diagnostics Division
Throughput: BC-3200 511 Benedict Ave.
Excell 2280
Tarrytown, NY 10591
Up to 110 CBC/hr Methodologies Used: Type of Analyzer:
3-part diff hematology analyzer Contact:
Time to First Result: Impedance and proprietary
Methodologies Used: Tina Johne
About 40 seconds laser technology
Impedance technology Head Global Communications
Sample Size: Tests Available in the U.S.:
Telephone: (914) 524-2429
300 mL WBC, 5 population differential number Throughput:
Fax: (914) 524-3693
Frequency of Calibration: and percentage, RBC, HgB, Hct, 60 tests/hour
tina.johne@siemens.com
Twice a Year Mcv, MCH, MCHC, RDW, Plt, MPV Sample Size:
http://diagnostics.siemens.com
Integrated Data Management: Throughput: 13 ul whole blood
Primary Product:
Yes 80 samples/hour Integrated Data Management:
ADVIA Centaur CP System
Open Reagent System: Time to First Result: Yes
Type of Analyzer:
No <1 minute Open Reagent System:
Random access immunoassay system
Primary Tube Sampling: Sample Size: Yes
Methodologies Used:
Yes Direct mode 180 uL; sample saver 80 uL Primary Tube Sampling:
Chemiluminescence
Positive Sample ID: Frequency of Calibration: Yes
Tests Available in the U.S.:
Yes Quarterly What differentiates your product from
other products on the market? Ferritin Folate Vitamin B12 BNP CKMB
Onboard Dilution: Integrated Data Management:
Sampling for either closed or (CKMB) Troponin (cTnl) Troponin I
Yes Yes
open tube; 4 position tube holder; Ultra (Tnl-Utlra) Homocysteine (HYC)
What differentiates your product from Open Reagent System:
micro sample size of 13 uL; large Myoglobin (MYO) Free T4 Free T3 T3
other products on the market? No
color LCD display; data storage of T4 TSH TSH-3 T-Uptake AFP (AFP)
WBC linearity extends from zero to Primary Tube Sampling: CEA (CEA) Complexed PSA (cPsa) PSA
35,000 samples with histogram
400,000; platelet linearity extends from Yes Estradiol-6 III FSH LH Progesterone
zero to 3 million; consistently accurate Positive Sample ID: Prolactin Total hCG Testosterone Digoxin
WBC, RBC, and platelet counts without Siemens Medical Solutions Diagnostics
Yes Throughput:
511 Benedict Ave.
manual intervention; advanced auto- Onboard Dilution: Up to 180 tests per hour in batch
Tarrytown, NY 10591
verification software; low review rates; Yes or random access mode
Contact:
performs six-part differentials, including What differentiates your product from Time to First Result:
Tina Johne
NRBCs; reticulocyte analysis; optional other products on the market? 15 minutes
Head Global Communications
integrated slidemaker/slidestainer; user- The 2280 uses multi-dimensional optical Telephone: (914) 524-2429 Sample Size:
defined decision rules help standardize scattering using a stable laser diode light Fax: (914) 524-3693 5 mL, 7 mL, 10 mL, 1mL
lab processes; remote monitoring and source to optimize the measurement tina.johne@siemens.com cups, microtainer tubes
diagnostics technology for increased of the WBC differential and a patented http://diagnostics.siemens.com Frequency of Calibration:
instrument uptime; backed by the platelet counting technique to improve Primary Product: Assay dependent, 3-28 days
industry’s top-rated service and support. the accuracy of platelet counting. ADVIA 2120 Hematology Analyzer Integrated Data Management:
Operational Type: Operational Type: Tests Available in the U.S.: Yes
Random access Continuous CBC results: WBC, RBC, HB, HCT, MCV, Open Reagent System:
Sample Handling System: Sample Handling System: MCH, MCHC, CHCM, RDW, HDW, CH, No
Cassettes 30-position autosampler CHDW, PLT. Differential results: (absolute
Primary Tube Sampling:
Number of Reagent Containers Number of Reagent Containers and %) NEUT, LYMPH, MONO, EOS, BASO,
Yes
Onboard/Tests/Container: Onboard/Tests/Container: LUC (Large Unstained Cells). Platelet
Positive Sample ID:
Five/varies 4 reagents results: PLT, MPV, PDW, PCT. Reticulocyte
results: absolute and % RETIC, Yes
Walkaway Capacity in Walkaway Capacity in
MCVr, CHCMr, RDWr**, HDWr**, CHr, What differentiates your product from
Specimen/Tests Assays: Specimen/Tests Assays:
CHDWr**. CSF assay results (optional) other products on the market?
Up to 144 samples at one time 30
Throughput: Continuous operation, no pause
System Liquid or Dry: System Liquid or Dry:
CBC - 120 samples/hr CBC/RETIC - 74 Separation Methodologies:
Liquid Liquid 84 samples, continuous loading
samples/hr CBC/DIFF - 120 samples/
Average Length of System Startup Average Length of Daily Startuptime hr RETIC - 74 samples/hr CBC/DIFF - in 12-position sample racks
Time and Daily Maintenance: and Daily Maintenance: 120 samples/hr RETIC - 74 samples/ Number of Reagent Containers
5-7 minutes <5 minutes hr CBC/DIFF/RETIC - 74 samples/hr Onboard/Tests/Container:
Sample Size: 15 reagents onboard, test per
Drew Scientific Mindray Co. Ltd. 175 uL container 50-200, assay dependent
4230 Shilling Way 8650 154th Ave. NE Integrated Data Management: Reagents Refrigerated Onboard:
Dallas, TX 75237 Redmond, WA 98052 Yes Barcode reagent identification,
Contact: Contact: Positive Sample ID: automatic inventory tracking and
Frank Matuszak Ray Xiang Yes flagging, calibration validity tracked
Vice president, Sales and Marketing Regional Manager Walkaway Capacity in and flagged, reagent on board
Telephone: (800) 433-0945 Telephone: (425) 881-0361 Specimen/Tests Assays: residency tracked and flagged,
Fax: (214) 210-4949 Fax: (425) 881-0879 Yes reagent expired/low flags
s

106 | July 2007 • advance /Laboratory • www.advanceweb.com


« laboratory analyzers buyers guide »
Walkaway Capacity in need to pause system to load Open Reagent System: Frequency of Calibration:
Specimen/Tests Assays: reagents, supplies or samples. True No Varies
One hour minimum stat capability with dedicated stat Integrated Data Management:
Primary Tube Sampling:
port, system easily samples from
Average Length of System Startup Yes Yes
automation rack or on system without
Time and Daily Maintenance: need for additional interface. Positive Sample ID: Open Reagent System:
No startup; 15 minutes Operational Type: Yes No
daily maintenance Continuous Primary Tube Sampling:
Onboard Dilution:
Separation Methodologies: Yes
Yes
Primary Product: Magnetic
What differentiates your product from Positive Sample ID:
ADVIA Centaur XP System Sample Handling System:
other products on the market? Yes
5 position universal rack
Type of Analyzer: Onboard Dilution:
Number of Reagent Containers Fastest throughput on the market;
Random access immunoassay system Yes
Onboard/Tests/Container: continuous random access analyzer;
Methodologies Used: 15 reagents onboard, test per What differentiates your product from
creates aliquot tubes from primary
Chemiluminescence container 50-200, assay dependent other products on the market?
sample tubes automatically; automation
Tests Available in the U.S.: Reagents Refrigerated Onboard: Continuous random access benchtop
ready; ease of use; innovative test
Allergy screen (ALSCRN) Total IgE Barcode reagent identification, automatic analyzer; ease of use, innovative
inventory tracking and flagging menu, including Hybritech PSA and
RefAllgn Specific IgE (sIgE) Specific test menu, including Hybritech PSA
calibration validity tracked and flagged, free PSA tests, Ostase® test for
Allergens Ferritin Folate RBC Folate and free PSA tests, Ostase® test for
reagent onboard residency tracked and osteoporosis and AccuTnIT troponin I;
Vitamin B12 BNP CK-MB II (CKMBII) flagged, reagent expired/low flags osteoporosis and AccuTnIT troponin
inhibin A; clot obstruction detection;
cTnI (ctnl) Homocysteine (HYC) Walkaway Capacity in I assay; Inhibin A; network capability
remote diagnostics; fully automated
Myoglobin (MYO) Tni-Ultra Rubella G Specimen/Tests Assays: for up to four Access 2 systems using
user-defined reflex testing
Rubella M Toxoplasma G Toxoplasma 840 test walkaway a single interface (Access 2); remote
Operational Type:
M aHAVM (aHAVM) aHAVT (aHAVT) System Liquid or Dry: diagnostics (Access 2); fully automated
aHBcM (aHBcM) aHBs (aHBs) aHCV Liquid Continuous random access
user defined reflex testing (Access 2);
(aHCV) HAVT (HAVT) HBcT (HBcT) HBs Average Length of System Startup Separation Methodologies:
onboard context sensitive help (Access
(HBs) EHIV (EHIV) Cortisol (Serum, Time and Daily Maintenance: Magnetic particle
No daily startup; daily maintenance 2); aliquot tube capability (Access 2)
Urine) C-peptide (Serum, Urine) Intact Sample Handling System:
is automated -40 minutes with Operational Type:
PTH Insulin Estradiol-6 Estradiol-6 III Rack
5 minutes hands-on time Continuous random access
FSH LH Progesterone Prolactin THCG Number of Reagent Containers
Separation Methodologies:
Testosterone Carbamazepine Digitoxin Onboard/Tests/Container:
Beckman Coulter Inc. Magnetic particle
Digoxin Gentamicin Phenobarbital 50 onboard/50 tests per
200 S. Kraemer Blvd. Sample Handling System:
Phenytoin Theophylline Tobramycin container, 100 tests per kit
Brea, CA 92822 Rack
Valproic Acid Vancomycin aTG (aTG) Reagents Refrigerated Onboard:
aTPO (aTPO) FrT4 (FrT4) FT3 (FT3) T3 Contact: Number of Reagent Containers
Yes
(T3) T4 (T4) TSH (TSH) TSH3 (TSH3) T Joel Greiner Onboard/Tests/Container:
Walkaway Capacity in
uptake (Tup) AFP BR (27.29) CA 125 CA Market Manager 24 onboard/50 tests per
Specimen/Tests Assays: container, 100 tests per kit
153 CA 199 CEA cPSA HER-2/neu PSA Telephone: (714) 993-8329
120/1200
Throughput: Fax: (714) 961-3825 Reagents Refrigerated Onboard:
System Liquid or Dry: Yes
240 tests/hour jcgreiner@beckman.com
Liquid
Time to First Result: www.beckmancoulter.com Walkaway Capacity in
Average Length of System Startup Specimen/Tests Assays:
18 minutes from start, resets Primary Product:
Time and Daily Maintenance: 60 specimens; 300 tests
every 15 seconds thereafter UniCel® DxI 800 Access®
System always available, approx. five System Liquid or Dry:
Sample Size: Immunoassay System
minutes of hands-on daily maintenance Liquid
10 mL to 200 mL; assay dependent Methodologies Used:
Frequency of Calibration: Chemiluminescent, magnetic particle Average Length of System Startup
Primary Product: Time and Daily Maintenance:
Most assays are 28 days; Tests Available in the U.S.: Access® Immunoassay System/ System always available, approx. five
minimum is 7 days Approximately 50 tests available in Access 2 Immunoassay System minutes hands-on daily maintenance
Integrated Data Management: the U.S., including thyroid, fertility, Methodologies Used:
Yes anemia, cardiovascular, adrenal/ Chemiluminescent, magnetic particle DiaSorin Inc.
Open Reagent System: pituitary, specialty, tumor markers,
Tests Available in the U.S.: 1951 Northwestern Ave.
No infectious disease and skeletal tests
Approximately 50 tests available in Contact:
Primary Tube Sampling: Throughput: the U.S., including thyroid, fertility, Kathleen Charlsen
Yes 400/hr anemia, cardiovascular, adrenal/ Inside Sales and Communications
Positive Sample ID: Time to First Result: pituitary, specialty, tumor markers, Telephone: (800) 328-1482 ext. 5762
Yes
Varies infectious disease and skeletal tests Fax: (651) 351-5669
Onboard Dilution:
Sample Size: Throughput: info@diasorin.com
Yes
5-200 mL 100/hr www.diasorin.com
Other Utility Requirements:
Frequency of Calibration: Time to First Result: Primary Product:
Deionized water Type II
Varies Varies Infectious Disease & Bone and Mineral
What differentiates your product from
other products on the market? Integrated Data Management: Sample Size: Type of Analyzer:
Continuous operation without the Yes 5-200 mL LIAISON® /immunoassay analyzer
s

108 | July 2007 • advance /Laboratory • www.advanceweb.com


« laboratory analyzers buyers guide »
Tests Available in the U.S.: Throughput: ImmunoCAP Specific IgE, Total IgE, Methodologies Used:
25-Hydroxyvitamin D, N-Tact TPTH, On average 10.96 well plates per shift Specific IgG*, ECP**, Tryptase**, EliA Chemiluminescence
EBV Igm, VCA IgG, EBNA IgG, EA IgG Time to First Result: CCP (Cyclic Citrullinated Peptide), EliA Tests Available in the U.S.:
CMV-IgM, CMV IgG,Toxo IgG,Toxo Variable incubation time tTG (Tissue Transglutaminase) IgA, IgG, AlaTOP allergy scr., 3gAllergy (IgE
IgM,Treponema pallidum, VZV IgG, Frequency of Calibration: EliA Gliadin IgA, IgG. ImmunoCAP 1000 specific allergens & allergy panels;
Borrelia burgdorferi and Direct Renin Per run Instrument: ImmunoCAP Specific IgE, includes tests for animals, drugs, dust,
Throughput: Integrated Data Management: Total IgE, Specific IgG*, ECP** *ASR: foods, grasses, insects, mites, molds,
Throughput varies by assay, Analyte Specific Reagent, Analytical
Yes occupational, parasites, trees, weeds),
typically 90-180
Open Reagent System: and performance characteristics total IgE, EPO, AFP, CEA, OM-MA (CA125),
Time to First Result: are not established. CLIA high
Yes PSA, 3rd-gen. PSA, FT3, TT3, TT4, FT4,
Varies, 1st result as soon as 17 min
Primary Tube Sampling: complexity certification required. TBG, thyrogl., anti-TG Ab, anti-TPO Ab,
Sample Size:
Yes **IUO: For Investigational Use Only. The
Assay dependent, 5 uL to 200 mL T-uptake, rapid TSH, 3rd-gen. TSH,
Positive Sample ID: performance characteristics of this
Frequency of Calibration: DHEA-SO4, estrad., FSH, androst., HCG,
Yes product have not been established.
Assay dependent, weekly or monthly LH, progest., prolac., total testost., α2-
Onboard Dilution: Throughput:
Integrated Data Management: microgl., cortisol, ferr., intact PTH, C-
Yes ImmunoCAP 100 Instrument: 48
Yes pep., folic acid, B12, insulin, unconj.
What differentiates your product from results in 2.5 hours, ImmunoCAP 250
Open Reagent System: estriol, carbamazep., phenytoin, valp.
other products on the market? Instrument: 370 allergy results in 8
No acid, hsCRP, hGH, ACTH, PAP, phenol,
Speed, productivity, 2 sample hours, 350 autoimmune results in 8
Primary Tube Sampling: homocysteine, CMV IgG (qualit.), H.
probe, software, runs on both hours. ImmunoCAP 1000 Instrument:
Yes pylori IgG, rubella IgG, toxo IgG, troponin
fixed disposable tips 1200 allergy tests in 8 hours
Positive Sample ID: I, CK-MB, herpes I & II IgG, Pyrilinks-D,
Yes Operational Type: Time to First Result:
myoglobin, toxo IgM, canine TSH, rubella
Onboard Dilution: Both 100 minutes
IgM, digoxin, digitoxin, anti-HBs, HBsAg,
Yes Sample Handling System: Sample Size:
HBsAg confirm., anti-HBc, anti HBc
What differentiates your product from Sample Carousel 40 microliters per allergy test and 20
Number of Reagent Containers microliters per autoimmune test IgM (contact Company for full menu)
other products on the market?
Select assays including 25-OH Onboard/Tests/Container: Frequency of Calibration: Throughput:
Vitamin D, Treponema pallidum, 8 onboard reagents Monthly 200/hour
Borrelia burgdorferi and Direct Renin Reagents Refrigerated Onboard: Integrated Data Management: Time to First Result:
give the laboratory some of the only no Yes 35 minutes
automated assays available today Walkaway Capacity in Sample Size:
Open Reagent System:
Operational Type: Specimen/Tests Assays: 5 uL to 100 uL sample
Yes
Random Access 400 Specimens
Primary Tube Sampling: Frequency of Calibration:
Sample Handling System: System Liquid or Dry: Yes 1-4 weeks (Assay Dependant)
Racks Liquid
Positive Sample ID: Integrated Data Management:
Number of Reagent Containers Average Length of System Startup
Onboard/Tests/Container: Yes Yes
Time and Daily Maintenance:
15 onboard reagents Onboard Dilution: Open Reagent System:
5 minutes
Reagents Refrigerated Onboard: Yes No
Yes Operational Type: Primary Tube Sampling:
Phadia US Inc.
Walkaway Capacity in ImmunoCAP 100 Instrument: Batch, Yes
4169 Commercial Ave.
Specimen/Tests Assays: ImmunoCAP 250/1000 Instruments:
Portage, MI 49002 Positive Sample ID:
Yes Continuous Random Access
Contact: Yes
System Liquid or Dry: Reagents Refrigerated Onboard:
Nicole Lampas Onboard Dilution:
Liquid ImmunoCAP 250/1000: Yes
Associate Product Manager Yes
Average Length of System Startup Average Length of System Startup
Telephone: (800) 346-4364 Other Utility Requirements:
Time and Daily Maintenance: Time and Daily Maintenance:
nicole.lampas@phadia.com Deionized Water, Dedicated Electric Line
5 minutes 15 Minutes
www.phadia.us
What differentiates your product from
Primary Product:
Grifols Diagnostics USA Division other products on the market?
ImmunoCAP Specific IgE Blood Test Siemens Medical Solutions Diagnostics
2410 Lillyvale Ave. Worldwide customer satisfaction,
Methodologies Used: 511 Benedict Ave.
Contact: system reliability and performance,
FEIA Tarrytown, NY 10591
Yvette Fearon flexibility of configuration to fit
Tests Available in the U.S.: Contact:
Marketing Specialist laboratory requirements , extensive
Telephone: (323) 441-7917 ImmunoCAP 100 Instrument: Tina Johne
Head Global Communications assay menu (ex: Allergy), Internet based
Fax: (323) 343-1806 ImmunoCAP Specific IgE, Total IgE,
Telephone: (914) 524-2429 service and support with RealTime
yvette.fearon@grifols.com Specific IgG*, Specific IgA*, Specific
IgG4**, ECP**, Tryptase**, Gliadin Fax: (914) 524-3693 Solutions (RTS) and OnLine Reports.
www.grifolsusa.com
Primary Product: IgA, Gliadin IgG, EliA CCP (Cyclic tina.johne@siemens.com Operational Type:
Triturus Automated EIA System Citrullinated Peptide), EliA tTG (Tissue http://diagnostics.siemens.com Continuous Random Access
Methodologies Used: Transglutaminase) IgA, IgG, EliA Gliadin Primary Product: Separation Methodologies:
ELISA IgA, IgG. ImmunoCAP 250 Instrument: IMMULITE 2000 Bead/Centrifugation
s

110 | July 2007 • advance /Laboratory • www.advanceweb.com


« laboratory analyzers buyers guide »
Sample Handling System: Other Utility Requirements: Other Utility Requirements: Operational Type:
RACK Deionized Water, Dedicated Electric Line 25. Deionized Water, Random and continuous access
Number of Reagent Containers What differentiates your product from Dedicated Electric Line Separation Methodologies:
Onboard/Tests/Container: other products on the market? What differentiates your product from Centrifugation
24 assay kits on board/ /200 tests per kit Worldwide customer satisfaction, other products on the market? Sample Handling System:
Reagents Refrigerated Onboard: system reliability and performance, Worldwide customer satisfaction, Sample cups
Yes Flexibility of configuration to fit system reliability and performance, Reagents Refrigerated Onboard:
Walkaway Capacity in laboratory requirements, extensive flexibility of configuration to fit laboratory Cooled
Specimen/Tests Assays: assay menu (ex: allergy), 15 minute requirements , extensive assay menu Walkaway Capacity in
90 specimens/4800 tests-assays stat cardiac results, on board test (ex: allergy), onboard test capacity of Specimen/Tests Assays:
System Liquid or Dry: capacity of 4800 tests, up to 5 hours of 9600 tests, up to 5 hours of usable .100
usable walkaway time Internet based walkaway time, unique Internet based System Liquid or Dry:
Liquid
service and support with RealTime service and support with RealTime Liquid
Average Length of System Startup
Solutions (RTS) and OnLine Reports. Solutions (RTS) and OnLine Reports.
Time and Daily Maintenance: Average Length of System Startup
Operational Type: Operational Type: Time and Daily Maintenance:
4 minute startup; daily
Continuous Random Access ~5 minutes for both
maintenance: 5-10 minutes Continuous Random Access
Separation Methodologies:
Separation Methodologies:
Bead/Centrifugation
Primary Product: Bead/Centrifugation Tosoh Bioscience Inc.
Sample Handling System: 6000 Shoreline Court, Ste. 101 South
IMMULITE 2500SMS Sample Handling System:
RACK San Francisco, CA 94080
Methodologies Used: RACK
Number of Reagent Containers Contact:
Chemiluminescence Number of Reagent Containers
Onboard/Tests/Container: Susan Surber
Tests Available in the U.S.: Onboard/Tests/Container:
Varies Field Marketing Manager
Cortisol, AlaTOP, Total IgE, 3gAllergy 24 reagents on board/ 200 tests per kit
Reagents Refrigerated Onboard: Telephone: (800) 248-6764
(IgE specific allergens & allergy panels; Reagents Refrigerated Onboard: YES Fax: (650) 615-0415
includes tests for animals, drugs, YES Walkaway Capacity in susan.surber@tosoh.com
dust, foods, grasses, insects, mites, Walkaway Capacity in Specimen/Tests Assays: www.tosohbioscience.us
occupational, parasites, trees, weeds), Specimen/Tests Assays: 350 specimens/9600 tests-assays Primary Product:
ferritin, EPO, calcitonin, Pyrilinks-D, 275 specimens/4800 tests-assays System Liquid or Dry: Automated Immunoassay Analyzers
homocys., hsCRP, insulin, C-peptide, urin. System Liquid or Dry: Liquid & HPLC HbA1c Analyzers
albumin, IGF-I, CMV IgG, rubella IgG/IgM, Liquid Average Length of System Startup Type of Analyzer:
toxo IgG/IgM, H. pylori IgG, AFP, androst., Average Length of System Startup Time and Daily Maintenance: Immunoassay
DHEA SO4, estrad., unconj. estriol, FSH, Time and Daily Maintenance: 4 minute Startup/Daily Methodologies Used:
LH, prolactin, progesterone, testosterone, 4 minute Startup/Daily Maintenance: 10 minutes Fluorescence, EIA/bead
SHBG, CK-MB, HCG, STAT troponin I, Maintenance: 5-10 minute Tests Available in the U.S.:
myoglobin, carbamazepine, digoxin,
Primary Product: TSH, 3rd Gen TSH, FT4, T3, T4, TT3, T-
phenytoin, phenobarbital, theophylline, IMMULITE 1000
Primary Product: Uptake, TPO Ab, Tg Ab, CKMB, Troponin
valp.acid, intact PTH, ACTH, α2-microgl.,
WORKCELL Methodologies Used: I 2nd Gen, Myoglobin, BHCG, Estradiol,
gastrin, hGH, IGFBP-3, herpes I & II IgG, Enzyme enhanced chemiluminecse
Methodologies Used: FSH, LH II, Prolactin, Progesterone,
digitoxin, anti-TG Ab, anti-TPO Ab, rapid
Chemiluminescence Tests Available in theU.S.: Testosterone, AFP, CEA, PSA, CA 125,
TSH, 3gen TSH, FT3, TT3, FT4, TT4, >80
Tests Available in the U.S.: 27.29, CA 19-9, Ferritin, B12, Folate,
T-uptake, thyrogl., BR-MA (CA 15-3), Cortisol, C-Peptide, HGH, Insulin,
Configuration dependent- Please Throughput:
CEA, OM-MA (CA125), PAP, PSA, 3gen Up to 120 tests per hours B-2 Microglobulin, IgE II, PAP
see IMMULITE 2000/2500 menu
PSA (contact company for full menu) Throughput:
Throughput: Time to First Result:
Throughput: 15, 42, 65 36, 60, 180 per hour
up to 200 tests/hour up to 400/hour
Sample Size: depending on instrument
Time to First Result: Time to First Result:
Assay dependent Time to First Result:
15 minutes 15-65 minutes
Frequency of Calibration: ~18 minutes
Sample Size: Sample Size:
Assay dependent, most 2 weeks Sample Size:
5 uL 17. 5 uL to 100 uL sample
Integrated Data Management: 10–100 mL
Frequency of Calibration: Frequency of Calibration:
Yes Frequency of Calibration:
1-4 weeks (assay dependant) 1-4 weeks (Assay Dependant) 30, 60, 90 days depending on assay
Open Reagent System:
Integrated Data Management: Integrated Data Management: No Integrated Data Management:
Yes Yes Yes
Primary Tube Sampling:
Open Reagent System: Open Reagent System: No Open Reagent System:
No No Onboard Dilution: No
Primary Tube Sampling: Primary Tube Sampling: Yes Primary Tube Sampling:
Yes Yes Other Utility Requirements: Yes
Positive Sample ID: Positive Sample ID: DI water Positive Sample ID:
Yes Yes What differentiates your product from Yes
Onboard Dilution: Onboard Dilution: other products on the market? Onboard Dilution:
Yes Yes Breath of menu Yes

112 | July 2007 • advance /Laboratory • www.advanceweb.com


« laboratory analyzers buyers guide »
What differentiates your product from Transferrin, N Latex Ferritin, N Latex Methodologies Used: Walkaway Capacity in
other products on the market? Homocysteine, N Latex IgM/IgA, N Nephelometric analysis of proteins Specimen/Tests Assays:
Unitized test cups, no reagent Latex IgE, N Latex Lp(a), N Latex RF, N in serum, plasma, urine and CSF 1.5 hour
preparation, dual clot detection, Latex sTfR, Plasminogen, Prealbumin, System Liquid or Dry:
Tests Available in the U.S.:
automated sample dilution and Retinol Binding Protein, Transferrin Liquid
α1-Antitrypsin, α1-Acid Glycoprotein,
pre-treatment, dry chemistry, Throughput: Average Length of System Startup
α2-Macroglobulin, α1-Microglobulin,
ideal for stat and routine use Time and Daily Maintenance:
70 tests per hour ß2-Microglobulin, ADNase B, Albumin,
Operational Type: Analyzer remains on; initial startup time
Time to First Result: Antithrombin III, Apo A-1, Apo B, C1
Continuous random access 8 minutes daily maintenance 5 minutes
6 minutes Esterase Inhibitor, C3c, C4, CardioPhase®
Separation Methodologies:
EIA/bead Sample Size: hsCRP, Ceruloplasmin, Cystatin C, • Tissue Processing
Sample Handling System: Multiple size primary tube Fibrinogen, Haptoglobin, IgG, IgA, IgM,
Rack sampling, including pediatrics Ig/Light Chain Type Kappa, Ig/Light Milestone Medical
Number of Reagent Containers Frequency of Calibration: Chain Type Lambda, IgG subclasses 1- 25 Controls Dr.
Onboard/Tests/Container: Shelton, CT 06484
Up to 6 weeks 4, Microalbumin, Myoglobin, N Latex
AIA 360: up to four different tests per Contact:
Integrated Data Management: ASO/ASL, N Latex Carbohydrate Deficient
patient; AIA 600II: up to five different Merrill Loechner
Yes Transferrin, N Latex Ferritin, N Latex Marketing Communications
tests per patient; AIA 1800: up to 31
Open Reagent System: Homocysteine, N Latex IgM/IgA, N Telephone: (203) 925-4240
different barcoded test cup trays
No Latex IgE, N Latex Lp(a), N Latex RF, N Fax: (203) 925-4241
Reagents Refrigerated Onboard:
Latex sTfR, Plasminogen, Prealbumin, mwave@milestonesci.com
No onboard refrigeration required Primary Tube Sampling:
Retinol Binding Protein, Transferrin www.milestonemed.com
Walkaway Capacity in Yes Primary Product:
Specimen/Tests Assays: Throughput:
Positive Sample ID: Microwave Accelerated Histoprocessors
Instrument dependent: AIA 360— Up to 225 tests per hour
Yes Type of Analyzer:
25 patients; AIA 600II—50 patients; Time to First Result:
Onboard Dilution: Microwave tissue processing
AIA 1800—170 patients 6 minutes
instrumentation
Yes Sample Size:
System Liquid or Dry: Throughput:
Dry test cup technology Other Utility Requirements: Multiple size primary tube
Semi- and fully-automated
Deionized water sampling, including pediatrics
Average Length of System Startup Time to First Result:
Time and Daily Maintenance: What differentiates your product from Frequency of Calibration:
15-20 minutes
5 minutes Up to 6 weeks
other products on the market? Sample Size:
Integrated Data Management:
Global leader in plasma protein 2–5 mm thick
• Nephelometry analysis; onboard refrigeration;
Yes
Open Reagent System:
Integrated Data Management:
extensive test menu; small sample size; Yes
Dade Behring Yes Open Reagent System:
wide measuring ranges; proprietary
1717 Deerfield Rd. Primary Tube Sampling: Yes
antigen excess security check
Deerfield, IL 60015 Yes Primary Tube Sampling:
Operational Type: Positive Sample ID:
Contact: No
Single, batch, profile, stat, random Yes
Amy Boyett Positive Sample ID:
Separation Methodologies: Onboard Dilution: Yes
Senior Communications Specialist
Nephelometry Yes Onboard Dilution:
Telephone: (847) 267-5300
Fax: (847) 236-7101 Sample Handling System: Other Utility Requirement: No
amy_boyett@dadebehring.com Rack Deionized water What differentiates your product from
www.dadebehring.com Number of Reagent Containers What differentiates your product from other products on the market?
Primary Product: Onboard/Tests/Container: other products on the market? Instrumentation is designed from the
Global leader in plasma protein ground up by scientists and is not based
BN ProSpec® System 30 bottles, 17 assays, 45 samples
analysis; high throughput; dedicated on the kitchen microwave as others are.
Methodologies Used: Reagents Refrigerated Onboard:
Plasma Protein System, extensive Operational Type:
Nephelometric analysis of proteins Yes test menu; small sample size; wide Semi- and fully-automated
in serum, plasma, urine and CSF Walkaway Capacity in measuring ranges; Proprietary Sample Handling System:
Tests Available in the U.S.: Specimen/Tests Assays: Antigen excess Security check Typical histoprocessing sample handling
α1-Antitrypsin, α1-Acid Glycoprotein, 1.5 hours Operational Type: Number of Reagent Containers
α2-Macroglobulin, α1-Microglobulin, single, batch, profile, stat, random Onboard/Tests/Container:
System Liquid or Dry:
ß2-Microglobulin, ADNase B, Albumin, Separation Methodologies: 2–5 (the use of Xylene is eliminated)
Liquid
Antithrombin III, Apo A-1, Apo B, C1 Nephelometry Walkaway Capacity in
Average Length of System Startup
Esterase Inhibitor, C3c, C4, CardioPhase® Sample Handling System: Specimen/Tests Assays:
hsCRP, Ceruloplasmin, Cystatin C, Time and Daily Maintenance:
Rack Yes
Fibrinogen, Haptoglobin, IgG, IgA, IgM, Analyzer remains on; initial startup time
Number of Reagent Containers System Liquid or Dry:
Ig/Light Chain Type Kappa, Ig/Light 8 minutes; daily maintenance 5 minutes Onboard/Tests/Container: Liquid
Chain Type Lambda, IgG subclasses 1- 100 bottles, 35 assays, 100 samples Average Length of System Startup
4, Microalbumin, Myoglobin, N Latex Primary Product: Reagents Refrigerated Onboard: Time and Daily Maintenance:
ASO/ASL, N Latex Carbohydrate Deficient BNT II System No None

www.advanceweb.com • advance /Laboratory • July 2007 | 113