Vous êtes sur la page 1sur 1

Pneumatics

TIGER 2000 5/2 SOLENOID/SOLENOID VALVE


G1⁄8 to G3⁄8 Port Size
This range of solenoid actuated 5/2 Valves combine a stand alone body
ported design with the ability to mount the valves on a common PRS rail
to produce a valve manifold.
Actuation is achieved by energising the coil (bought separately). The A B

valve retains its actuated position, even after the signal is removed, until
C
a counter signal is applied. Manual override as standard.
D

Not suitable for vacuum applications, please contact Technical Sales. E F GG

Medium: Temperature Range: J

Compressed air, filtered (lubricated -5°C to +50˚C K

or unlubricated). L

Standard Voltages:
Design: 12 & 24 VDC, 24, 42, 110, Housing Materials: Power Consumption:
Solenoid valve 230VAC, 50 or 60 Hz Die Cast Aluminium DC: 4.5 W
AC: hold 6VA
Mounting: Protection, (with socket): Seals: pull 7.5VA
Clearance holes through housing. IP65 Perbunan

Order Code Working Flow Rate Response Working Operation


Pressure Time Lines
(bar) (6 bar) ms Connection
JMFH-5-1/8-B 2 to 10 1000l/min 14 G1/8 5/2 Sol/Sol JMFH-5-1/8-B
JMFH-5-1/4-B 2 to 10 1600l/min 16 G1/4 5/2 Sol/Sol JMFH-5-1/4-B
JMFH-5-3/8-B 2 to 10 2000l/min 16 G3/8 5/2 Sol/Sol JMFH-5-3/8-B

Type A B C D E EE F G H J K L
Tiger 2000 5/2 Solenoid/Solenoid Valve - G1/8 64.5 38.5 26 42 47 41 40 - 75.5 21 129 264
Tiger 2000 5/2 Solenoid/Solenoid Valve - G1/4 70.5 44 32 48 53 46 44 - 80 24 141 275
Tiger 2000 5/2 Solenoid/Solenoid Valve - G3/8 61 50 40 64 70 61.4 51 12 100 32 123 253

TIGER 2000 5/3 SOLENOID/SOLENOID VALVE


G1⁄8 to G3⁄8 Port Size
This range of solenoid actuated 5/3 Valves combine a stand alone body
ported design with the ability to mount the valves on a common PRS rail
to produce a valve manifold. A B

Actuation is achieved by energising the coils (bought separately). Manual C

override as standard. Not suitable for vacuum applications, please


D
contact Technical Sales. E F GG

Medium: Temperature Housing Materials:


Compressed air, Range: Die Cast Aluminium G
filtered (lubricated or -5°C to +50˚C H

unlubricated). Seals:
Standard Voltages: J
Perbunan
Design: 12 & 24 VDC
K
Solenoid valve. 24, 42, 110, 230VAC Power Consumption: L

Mounting: 50 or 60 Hz DC: 4.5 W


Clearance holes Protection, AC: hold 6VA
through housing. (with socket): IP65 pull 7.5VA
Functions: G spool has the neutral position closed. Double acting cylinders can be halted Neutral Position
briefly, within their stroke range. E spool has the neutral position exhausted. With double acting MFH-5/3G-1/8-B Closed
cylinders, the piston rod is free to move, no pressure is present. B spool has the neutral MFH-5/3G-1/4-B Closed
position vented. With double acting cylinders the piston rod is clamped under pressure. MFH-5/3G-3/8-B Closed
Order Code Working Flow Response Time Working Operation MFH-5/3E-1/8-B Exhausted
Pressure Rate On Off Lines MFH-5/3E-1/4-B Exhausted
(bar) (6 bar) ms (6 bar) ms Connection MFH-5/3E-3/8-B Exhausted
MFH-5/3...-1/8-B 3 to 10 1000 l/min 30 35 G1/8 5/3 Sol/Sol MFH-5/3B-1/8-B Vented
MFH-5/3...-1/4-B 2 to 10 1600 l/min 19 22 G1/4 5/3 Sol/Sol MFH-5/3B-1/4-B Vented
MFH-5/3...-3/8-B 3 to 10 2000 l/min 30 70 G3/8 5/3 Sol/Sol MFH-5/3B-3/8-B Vented

Type A B C D E EE F G H J K L
Tiger 2000 5/3 Solenoid/Solenoid Valve – G1/8 64.5 38.5 26 42 47 41 40 - 75.5 21 129 263
Tiger 2000 5/3 Solenoid/Solenoid Valve – G1/4 70.5 44 32 48 53 46 44 - 80 24 141 275
Tiger 2000 5/3 Solenoid/Solenoid Valve – G3/8 81 50 40 64 70 61.4 51 12 100 32 163 293

TECH SHEET FTS26