Académique Documents
Professionnel Documents
Culture Documents
Series
INVERTER LINE- UP
24A2-E-0020
Fuji Inverter Family Consisting of a Diverse Lineup
High performance
Advanced function High Performance Vector Control Inverter Direct parallel connection
Stack Type Three-phase 400V to 2,400kW
Three-phase 400V 30 to 800kW Three-phase 690V to 1,200kW
Three-phase 690V 90 to 450kW
Compact Inverters
2
Diversifying Fuji inverter applications :Best suitable :Suitable
Representative Application
Classification
instrument image example
3
Digital
input X
Capacity range
terminal Digital
(application Overload Analog Analog Output
Series name Input voltage class including input Y
motor capacity) capability input output frequency range
FWD/ terminal
[kW]
REV
terminal
4
Auto-restart after momentary power failure
PID control
Torque limiter
3
4
2
2
Number of motor switching options
Hit-and-stop control
*2
Dancer roll control
Calendar function
Traceback function
Online tuning
Pump control
*1 The behavior of analog input and output can be switched by settings. Refer to the catalogue of each series.
5
Special option
Applicable inverter
Operation
Remote touch panel with USB Standard
option
*1 The number of connectors of the RS-485 port can be changed from 1 to 2 by mounting an option card.
6
Wiring diagram of peripheral equipment of inverter
For main power input and Power 3 External operation, measurement and communication Built-in option card
inverter output
Remote touch panel ■ Control option card
*1 If not using an R0, T0 terminal, connect a connector R S T [TP-E1], [TP-A1-E2C], [TP-G1-J1],
at this location.
MCCB
or
[TP-G1-C1], [TP-E1U] ・Relay Output Interface Card
ELCB
U V W
Used for remote operation of the inverter
[OPC-■-RY]
Conversion of transistor outputs of the
Arrester Consult our sales inverter to relay output signals
[CN513 ] representatives Extension cable for remote control
※1
[CB-□S] ・Digital Interface Card
Suppresses induced lightning surges from the Contactor [OPC-■-DIO], [OPC-G1-DI/DO]
Cable used for remote control Frequency setting with binary or BCD
power source to protect entire equipment
digital signals
connected to the power source.
・Analog Interface Card
[OPC-■-AIO]
Ferrite ring for reducing radio noise Torque control with external analog
[ACL-40B, ACL-74B, F200160] signals
:\WWYLZZÅ\J[\H[PVUZVMTV[VY[LYTPUHS]VS[HNL
7YL]LU[KHTHNLZ[V[OLTV[VYPUZ\SH[PVUK\L[VZ\YNL
voltage in 400V series inverter.
;OPZÄS[LYPZUV[SPTP[LKI`JHYYPLYMYLX\LUJ`(SZVTV[VY
can be tuned while this option is installed. DC reactor Braking unit Attachment for IP40
X1 Y1 Z1 [DCR - ] [BU - C] [P40■-□□]
Surge supperession unit [For power supply normalization] To be used together with a braking
Converting the protection structure of
[SSU TA-NS]
X2 Y2 Z2 the inverter to all-closed form (IP40)
1) Use if the power transformer resistor to increase the inverter
braking performance.
capacity is 500kVA or more and NEMA 1 kit
Surge voltage is generated if the cable between an inverter and exceeds the inverter rated capacity
Power regenerative PMW converter, [NEMA1-□□□■-□]
a motor is several ten meters long. This product suppresses by 10 times. RHC series
the surge voltage, preventing the motor from being damaged. 2) Use if the inverter and a thyristor
[RHC - C]
Converting the protection structure of
(Can be used for motors of 75kW or lower.) converter are connected to the same the inverter to NEMA 1 standards
(certified for UL TYPE 1)
transformer. Used for suppressing power source
R S T G *Check if the thyristor converter uses a harmonics of inverters. It is also Compatibility attachment
Surge killer Motor
commutation reactor. If not,an AC reactor
must be connected to the power supply side. equipped with a power supply
[MA-■-□□]
M 3) Connect to prevent trips when trip regenerative function to drastically
3
Absorbs surge voltage coming from L-load of magnetic occurs due to opening/closing of the increase braking capability and An attachment for providing mount
contactor and solenoid valve to protect electronic phase-advancing capacitor for the reduce energy consumption. compatibility with old models
devices from malfunctioning. Braking resistor power supply lines. * Use in combination with the RHC
manufactured by our company
[DB - ,DB - C] 4) Use if the voltage unbalance exceeds Series dedicated pressurization reactor,
resistor, and capacitor. Rail mount base
Consult our sales
Surge absorber representatives 2%.
[RMA-■-□□]
Increases braking capability [For improving the input power-factor +LKPJH[LKÄS[LYMVY9/*ZLYPLZ
(Connect in parallel to the coil that is a generation source of surge.)
for highly frequent stopping and reducing harmonics] (ÄS[LYKLKPJH[LKMVY9/*ZLYPLZ An attachment for mounting to IEC rail
[S2-A-O (for magnetic contactor and solenoid valve)] ●Used to reduce the input harmonic which is used when other electronic with a width of 35 mm
and large moment of inertia.
[S1-B-O (for mini control relay and timer)] current (correcting power-factor) devices are connected to the same
When used together with a
* For the drop effect, refer to the guideline power supply. An attachment for external cooling
Surge killer for L-load
braking unit, connect this to appendix. [PB-■-□□]
<ZL[OPZÄS[LYPUJVTIPUH[PVU^P[O[OL
the connection terminal of
(Connect to the power circuit that is a generation source of surge.) KLKPJH[LKÄS[LYYLHJ[VYÄS[LYJVUKLUZLY An attachment for taking the cooling
the braking unit. HUKÄS[LYYLZPZ[VYHZHZL[
fin of the inverter out of the board
[FSL-323 (for 3-phase)]
[FSL-123 (for single -phase)] Peripheral and structure options
* The series names (C2, E2, G1, F1, VG1) are put in the place of ■ in the type names.
7
Fuji Inverter Family Contributing with a Diverse Lineup
Standard Semi-standard
product product
Compact Inverters
● Series of compact inverters equipped with functions ideal for diverse small capacity needs
● Frequency setting volume control provided as standard equipment, allowing easy operation
● Dynamic torque-vector control, PDI control function, cooling fan ON/OFF control function
and synchronous motor control provided
2*JLY[PÄJH[PVU
Built-in
EMC filter
Variable Torque Load Inverters for Fans and Pumps ● Series of inverters developed exclusively for square reduction loads such as fans and pumps
● Equipped with various functions including new system of automatic energy saving, PID control,
life expectancy prediction and commercial power supply operation switching sequence
● Ideal for air-conditioning systems, fans and pumps, for which conventional
general-purpose inverters could not be used due to cost and function issues
High Performance Inverters ● Series of inverters applicable to diverse applications ranging from simple variable-speed
applications to business sector-specific machines requiring high performance and
multiple functions
● Capable of four load ratings according to applied load, optimizing total cost and offering
space-saving performance *1
● Customizable logic function provided as standard feature to allow up to 200 steps of programming
HHD HND
HD ND *2
2*JLY[PÄJH[PVU
Built-in Customizable Four Functional
EMC filter logic ratings safety STO
Inverter for HVAC Applications ● Series of inverters equipped with energy-saving and special functions required for air
conditioning market and designed exclusively for specific market
● EMC filter and DC reactor (DCR) provided as standard equipment *1
● Equipped with functions suited for air conditioning applications including 4PID control,
real time clock, torque-vector control, filter clogging prevention and linearization function
Optimized
minimum
power control
Three-phase200V/0.75 to 90kW
Three-phase400V/0.75 to 710kW
Three-phase575V/0.75 to 220kW
*1 DC reactors of three-phase 200 V: 0.75 to 45 kW and three-phase 400 V: 0.75 to 90 kW are built in *2 Compatible with three-phase 200 V: 0.75 to 45kW and three-phase 400 V: 0.75 to 90 kW.
High Performance Multifunctional Inverters ● Series of general-purpose inverters provided with best-in-class vector functions including
vector control with and without speed sensor, PG vector control, dynamic torque vector
control and V/f control
● Various functions suited for applications available such as improved brake signal, dancer
control function, pulse train input function, ratio operation and customizable logic function
● Built-in USB board allowing management of various types of inverter information, facilitating maintenance
● Provided with vector control with and without speed sensor and V/f control
● Full-fledged maintenance functions enabled by calendar function and traceback
● Safety function (STO) compliant with functional safety standard EN61800-5-2 provided as standard feature
● Stack type three-phase 690 V 355 to 450 kW provided with new device (SiC hybrid module) capable
of realizing significant reduction of generated loss as compared with conventional Si module
● A Marine standard compatible product lineup has been added as semi-standard products.(Certifying
body:DNV GL classification societies)*1*2
2*JLY[PÄJH[PVU
Functional Position Load Calendar
:[HJR[`WL!WLUKPUNJLY[PÄJH[PVU
safety STO control compensating
control
function
FRN 0010 C 2 S - 2 A
Code Series name Code Destination / Instruction Manual
FRN FRENIC Series A Asia/English
E Europe/English
Code Nominal applied motor capacity U USA/English
0001 0.1kW C China/Chinese
J Japan/Japanese
0060 15kW
Code Input power source
Code Application range 2 Three-phase 200V
C Compact 4 Three-phase 400V
6 Single-phase 100V
Code Developed inverter series 7 Single-phase 200V
2 2series
Code Structure
S Standard (IP20)
E )\PS[PU,4*ÄS[LY(IP20)
FRN 5.5 F 1 S - 2 A
Code Series name Code Destination / Instruction Manual
FRN FRENIC Series A Asia/English
E Europe/English
Code (kW)[HP] Nominal applied motor capacity U USA/English
0.75 [001] 0.75kW J Japan/Japanese
∼
FRN 0004 E 2 S - 2 GB
Code Series name Code Destination / Instruction Manual
FRN FRENIC Series GA, GB *1 Global/English
E Europe/English
Code Nominal applied motor capacity C China/Chinese
0001 0.1kW K Korea/Korean
J Japan/Japanese
0590 315kW *1 Control terminals differ between GA model and GB model.
For details, please refer to the FRENIC-Ace catalog.
10
FRN 3.7 AR 1 L - 4 A
Code Series name Code Destination / Instruction Manual
FRN FRENIC Series A Asia/English
E Europe/English
Code (kW)[HP] Nominal applied motor capacity U USA/English
0.75 [001] 0.75kW J Japan/Japanese
FRN 0.75 G 1 S - 2 A
Code Series name Code Destination / Instruction Manual
FRN FRENIC Series A Asia/English
E Europe/English
Code (kW)[HP] Nominal applied motor capacity U USA/English
0.4 [001] 0.4kW C China/Chinese
∼
T Taiwan/English
630 [900] 630kW J Japan/Japanese
FRN 30 S VG 1 S - 4 E
Code Series name Code Destination / Instruction Manual
FRN FRENIC Series E English
C Chinese
Code Nominal applied motor capacity
J Japanese
0.75 0.75kW
Code Input power source
800 800kW 2 Three-phase 200V
4 Three-phase 400V
Code Form
69 Three-phase 690V
None Unit type
S Standard stack Code Structure
B Stack by phase S Standard
11
Overseas service network
Singapore
Indonesia
Jakarta
Australia
*Note: See the pages listed for detailed company and contact information.
12
USA, Canada and Latin America region
na region
Canada
Seattle
Portland Chicago New York
San Francisco
Sioux Falls
Charlotte
USA
San Jose
Norfolk
Los Angeles
Japan Long Beach Jacksonville
Houston
Mexico
Panama
Panama City
Venezuela
Latin America
Sao Paulo
Sydney
Auckland
New Zealand
eania
13
Far East Asia & China Area
D
Beijing
D
CHINA
Seoul
N
Tokyo
KOREA Suzuka
)XML)$6HUYLFH&HQWHUV
E F G
E J Taipei
Shenzhen &RQWUDFWHG6HUYLFH&RPSDQLHV
TAIWAN
6XEFRQWUDFWHG&RPSDQLHV
&RPPLVVLRQ6HUYLFH&RPSDQLHV
$SSOLFDEOH3URGXFWV
0DUN 1DPH $GGUHVV3KRQHHWF %XVLQHVV+RXUV (QJOLVK
0LQRUWURXEOH 0DMRUWURXEOH
α β W ALPHA5 ALPHA5
Smart Motor α β W ALPHA5 ALPHA5
Smart Motor
14
INV ≦ 22kW INV ≧ 30kW Medium Voltage
General Purpose Inverter, below 22kW General Purpose Inverter, above 30kW Medium Voltage Inverter
Vector Inv Machine Tool Inv PLC POD
Vector Inverter Machine Tool Inverter PLC POD
$SSOLFDEOH3URGXFWV
0DUN 1DPH $GGUHVV3KRQHHWF %XVLQHVV+RXUV (QJOLVK
0LQRUWURXEOH 0DMRUWURXEOH
:X[L;LQTL\XDQ 1R:X[L1DWLRQDO,QGXVWULDO'HVLJQ ∼ <HV INV≦22kW INV≧30kW Medium Medium
3DUFN+RQJTLDR5RDG/L\XDQ(FRQRPLF (*07KRXUV) Voltage INV≦22kW INV≧30kW Voltage
7HFKQRORJ\&R/WG
I 'HYHORSLQJ=RRQ:X[L-LDQJVX&KLQD Vector Inv Machine Machine
Tool Inv PLC POD Vector Inv Tool Inv PLC POD
・3KRQH
・)D[ α β W ALPHA5 ALPHA5
Smart Motor α β W ALPHA5 ALPHA5
Smart Motor
Contact your local Fuji Electric sales affiliate to request after-sales service (including spare parts for power distribution/control equipment).
15
Southeast Asia & Oceania
2C 2 e
Dubai INDIA
2-1
Mumbai THAILAND
2a 2 a Vietnam
Bangkok
2d
Ho Chi Minh
2b
2 2A
Kuala Lumpur
Singapore
2 c 2b
Jakarta
INDONESIA
AUSTRALIA
2B
Sydney
2c
Auckland
NEW ZEALAND
Fuji FA Service Centers
Sub-contracted Companies
16
INV ≦ 22kW INV ≧ 30kW Medium Voltage
General Purpose Inverter, below 22kW General Purpose Inverter, above 30kW Medium Voltage Inverter
Vector Inv Vector Inverter Machine Tool Inv Machine Tool Inverter PLC POD
PLC POD
α Servo α β Servo β W Servo W ALPHA5 ALPHA5 Smart Motor
ALPHA5 ALPHA5 Smart Motor
Applicable Products
Mark Name Address, Phone etc. Business Hours English
Minor trouble Major trouble
South East & Oceania 151 Lorong Chuan, 08:45 ∼ 17:30 Yes INV≦22kW INV≧30kW Medium Medium
#03-01/01A New Tech Park lobby A, Voltage INV≦22kW INV≧30kW Voltage
Service Centre (GTM +8hours)
2 Singapore 556741
・Phone : +65-6533-0010
Vector Inv Machine Machine
Tool Inv PLC POD Vector Inv Tool Inv PLC POD
・Fax : +65-6533-0021 α β W ALPHA5 ALPHA5
Smart Motor α β W ALPHA5 ALPHA5
Smart Motor
Fuji Electric India Private 503, A-wing, Dynasty Business Park, 08:45 ∼ 17:30 Yes INV≦22kW INV≧30kW Medium Medium
Andheri-Kurla Road And-heri (East), Voltage INV≦22kW INV≧30kW Voltage
Limited (GTM +5.5hours)
2-1 Mumbai-400 059, India
・Web : www.fujielectric.co.in
Machine Machine
Vector Inv Tool Inv PLC POD Vector Inv Tool Inv PLC POD
・Phone : +91-22-4010-4870 α β W ALPHA5 ALPHA5
Smart Motor α β W ALPHA5 ALPHA5
Smart Motor
Fuji Technical Centre 48 Toh Guan Road East #09-110, 08:30 ∼ 18:00 Yes INV≦22kW INV≧30kW Medium Medium
Enterprise Hub Singapore 608586 Voltage INV≦22kW INV≧30kW Voltage
(S'pore) Pte Ltd. (GTM +8hours)
2A ・Phone : +65-6515-5970, 5971 Machine Machine
Vector Inv Tool Inv PLC POD Vector Inv Tool Inv PLC POD
・Fax : +65-6515-5155
α β W ALPHA5 ALPHA5
Smart Motor α β W ALPHA5 ALPHA5
Smart Motor
Fuji Technical Centre 8 Soi Lasalle 77, Kwaeng Bangna, 08:30 ∼ 17:30 Yes INV≦22kW INV≧30kW Medium Medium
Khet Bangna, Bangkok 10260, Thailand (GTM +7hours) Voltage INV≦22kW INV≧30kW Voltage
(Thailand) Co., Ltd.
2a ・Phone : +66-2393-8904 ∼ 6 Vector Inv Machine Machine
Tool Inv PLC POD Vector Inv Tool Inv PLC POD
・Fax : +66-2393-8909
α β W ALPHA5 ALPHA5
Smart Motor α β W ALPHA5 ALPHA5
Smart Motor
PT. Unitama Sentosa Jl. R. E. Martadinata Kompleks Permata 08:30 ∼ 17:30 Yes INV≦22kW INV≧30kW Medium Medium
Ancol Blok N -32 Jakarta Utara Indonesia (GTM +7hours) Voltage INV≦22kW INV≧30kW Voltage
Gemilang
2b ・Web : www.unitama.co.id Vector Inv Machine Machine
Tool Inv PLC POD Vector Inv Tool Inv PLC POD
・Phone : +62-21-6451132 / 34 / 35
・Fax : +62-21-6451130 α β W ALPHA5 ALPHA5
Smart Motor α β W ALPHA5 ALPHA5
Smart Motor
CSE-UNISERVE PTY. 10 Columbia Way Baulkham Hills 08:30 ∼ 17:00 Yes INV≦22kW INV≧30kW Medium Medium
NSW 2153 Australia Voltage INV≦22kW INV≧30kW Voltage
LIMITED (GTM +10hours)
2B ・Web : www.cse-uniserve.com.au Vector Inv Machine Machine
Tool Inv PLC POD Vector Inv Tool Inv PLC POD
・Phone : +61-2-8853-4200
・Fax : +61-2-8853-4281 α β W ALPHA5 ALPHA5
Smart Motor α β W ALPHA5 ALPHA5
Smart Motor
CSE-Uniserve NZ Limited Unit F, 55 Druces Road Manukau Clity, 08:30 ∼ 17:00 Yes INV≦22kW INV≧30kW Medium Medium
Voltage INV≦22kW INV≧30kW Voltage
New Zealand (GTM +12hours)
2c ・Web : www.cse-waf.co.nz Machine Machine
Vector Inv Tool Inv PLC POD Vector Inv Tool Inv PLC POD
・Phone : +64-9-271-3810
・Fax : +64-9-262-3292 α β W ALPHA5 ALPHA5
Smart Motor α β W ALPHA5 ALPHA5
Smart Motor
DUBAI ENGINEERING P.O.Box:46818, Sharjah, U.A.E. 08:00 ∼ 12:30 Yes INV≦22kW INV≧30kW Medium Medium
・Web : www.dubai-engineering.com Voltage INV≦22kW INV≧30kW Voltage
13:30 ∼ 18:00
2C ・Phone : +971-6-5551141
(GTM +4hours) Vector Inv Machine Machine
Tool Inv PLC POD Vector Inv Tool Inv PLC POD
・Fax : +971-6-5551181
α β W ALPHA5 ALPHA5
Smart Motor α β W ALPHA5 ALPHA5
Smart Motor
S.T. Control Co., Ltd. 84/1,Soi Ramkhamhaeng 9 (Thararom), 08:00 ∼ 17:00 Yes INV≦22kW INV≧30kW Medium Medium
Ramkhamhaeng Road, Wangthonglang, Bangkok 10310. (GTM +7hours) Voltage INV≦22kW INV≧30kW Voltage
2a ・Web : www.stcontrol.com Vector Inv Machine Machine
・Phone : +66-2-319-2559 Tool Inv PLC POD Vector Inv Tool Inv PLC POD
・Fax : +66-2-319-1800 α β W ALPHA5 ALPHA5
Smart Motor α β W ALPHA5 ALPHA5
Smart Motor
EITA Electric Sdn. Bhd. Lot 4, Block A, Jalan SS13/7,Subang Jaya Industrial Estate, 08:30 ∼ 18:00 Yes INV≦22kW INV≧30kW Medium Medium
47500 Subang Jaya,Selangor Darul Ehsan, Malaysia. Voltage INV≦22kW INV≧30kW Voltage
(GTM +8hours)
2b ・Web : www.eita.com.my Vector Inv Machine Machine
・Phone : +60-3-5637 8088 Tool Inv PLC POD Vector Inv Tool Inv PLC POD
・Fax : +60-3-5635 4719 α β W ALPHA5 ALPHA5
Smart Motor α β W ALPHA5 ALPHA5
Smart Motor
PT. DUTA FUJI ELECTRIC JL. HAYAM WURUK 4F-H, JAKARTA 10120 08:00 ∼ 17:00 Yes INV≦22kW INV≧30kW Medium Medium
Voltage INV≦22kW INV≧30kW Voltage
・Web : www.dutafuji.com (GTM +7hours)
2c ・Phone : +62-21-384-0834 Machine Machine
Vector Inv Tool Inv PLC POD Vector Inv Tool Inv PLC POD
・Fax : +62-21-352-1208,352-1207
α β W ALPHA5 ALPHA5
Smart Motor α β W ALPHA5 ALPHA5
Smart Motor
Hao Phuong Co.,Ltd. 7/31 Song Than Business Center, 08:00 ∼ 12:00 Yes INV≦22kW INV≧30kW Medium Medium
Di An Ward,Binh Duong Province, Vietnam 13:30 ∼ 17:00 Voltage INV≦22kW INV≧30kW Voltage
2d ・Web : www.haophuomg.com Vector Inv Machine Machine
・Phone : +84-650-3737619 (Sat.:08:00∼12:00) Tool Inv PLC POD Vector Inv Tool Inv PLC POD
・Fax : +84-650-3737620 (GMT +7hours) α β W ALPHA5 ALPHA5
Smart Motor α β W ALPHA5 ALPHA5
Smart Motor
ELECTRONIC Industrial No.15, Street No.105, W.H No.10, 08:00 ∼ 18:00 Yes INV≦22kW INV≧30kW Medium Medium
P.O.BOX 69408, SHARJAH (U.A.E) Voltage INV≦22kW INV≧30kW Voltage
CONTROL IND. (GMT +4hours)
2e SERVICES LLC ・Web : www.ecisuae.com Vector Inv Machine Machine
・Phone : +971-6535-1971 Tool Inv PLC POD Vector Inv Tool Inv PLC POD
・Fax : +971-6535-1972 α β W ALPHA5 ALPHA5
Smart Motor α β W ALPHA5 ALPHA5
Smart Motor
Contact your local Fuji Electric sales affiliate to request after-sales service (including spare parts for power distribution/control equipment).
17
Europe, Middle East & Africa Area
U.K.
$ GERMANY
London '
Frankfurt
FRANCE Nurnberg
% Paris
Altenhein
SWITZERLAND
G
& Milan Craiova
ITALY
E
D Barcelona Istanbul
SPAIN
TURKEY
RUSSIA
F
Moscow
U.K. GERMANY
FRANCE
SWITZERLAND
ITALY
SPAIN TURKEY
AFRICA
)XML)$6HUYLFH&HQWHUV
&RQWUDFWHG6HUYLFH&RPSDQLHV
6XEFRQWUDFWHG&RPSDQLHV
&RPPLVVLRQ6HUYLFH&RPSDQLHV
18
INV ≦ 22kW INV ≧ 30kW Medium Voltage
General Purpose Inverter, below 22kW General Purpose Inverter, above 30kW Medium Voltage Inverter
Vector Inv Vector Inverter Machine Tool Inv Machine Tool Inverter PLC POD
PLC POD
α Servo α β Servo β W Servo W ALPHA5 ALPHA5 Smart Motor
ALPHA5 ALPHA5 Smart Motor
$SSOLFDEOH3URGXFWV
0DUN 1DPH $GGUHVV3KRQHHWF %XVLQHVV+RXUV (QJOLVK
0LQRUWURXEOH 0DMRUWURXEOH
6$7(1*,1((5,1* 9LD3DOHUPR$VVDJR0,,WDO\ ∼ : <HV INV≦22kW INV≧30kW Medium Medium
・:HE ZZZVDWHQJLQHHULQJFRP Voltage INV≦22kW INV≧30kW Voltage
65/ (*07KRXU)
& ・3KRQH Machine Machine
Vector Inv Tool Inv PLC POD Vector Inv Tool Inv PLC POD
・)D[
α β W ALPHA5 ALPHA5
Smart Motor α β W ALPHA5 ALPHA5
Smart Motor
19
USA, Canada, Central & South America Area
'
CANADA Panama City
VENEZUELA
Seattle PANAMA
D
Portland
I Sioux Fslls
J $
Chicago New York
San Francisco
San Jose USA &
% E Charlotte Norfolk
Los Angeles CENTRAL & SOUTH AMERICA
F G
Long Beach Jacksonville
Houston H K
MEXICO São Paulo
)XML)$6HUYLFH&HQWHUV
&RQWUDFWHG6HUYLFH&RPSDQLHV
6XEFRQWUDFWHG&RPSDQLHV
&RPPLVVLRQ6HUYLFH&RPSDQLHV
$SSOLFDEOH3URGXFWV
0DUN 1DPH $GGUHVV3KRQHHWF %XVLQHVV+RXUV (QJOLVK
0LQRUWURXEOH 0DMRUWURXEOH
α β W ALPHA5 ALPHA5
Smart Motor α β W ALPHA5 ALPHA5
Smart Motor
20
INV ≦ 22kW INV ≧ 30kW Medium Voltage
General Purpose Inverter, below 22kW General Purpose Inverter, above 30kW Medium Voltage Inverter
Vector Inv Vector Inverter Machine Tool Inv Machine Tool Inverter PLC POD
PLC POD
α Servo α β Servo β W Servo W ALPHA5 ALPHA5 Smart Motor
ALPHA5 ALPHA5 Smart Motor
$SSOLFDEOH3URGXFWV
0DUN 1DPH $GGUHVV3KRQHHWF %XVLQHVV+RXUV (QJOLVK
0LQRUWURXEOH 0DMRUWURXEOH
α β W ALPHA5 ALPHA5
Smart Motor α β W ALPHA5 ALPHA5
Smart Motor
α β W ALPHA5 ALPHA5
Smart Motor α β W ALPHA5 ALPHA5
Smart Motor
Contact your local Fuji Electric sales affiliate to request after-sales service (including spare parts for power distribution/control equipment).
21
NOTES
Reducing noise
When running general-purpose motors Environmental conditions Use of a filter and shielded wires are typical
Driving a 400V general-purpose motor Installation location measures against noise to ensure that EMC
When driving a 400V general-purpose motor with Use the inverter in a location with an ambient Directives are met.
an inverter using extremely long cables, damage to temperature range of -10 to 50ÝC. Measures against surge currents
the insulation of the motor may occur. Use an output The inverter and braking resistor surfaces become If an overvoltage trip occurs while the inverter is
circuit filter (OFL) if necessary after checking with hot under certain operating conditions. Install the stopped or operated under a light load, it is
the motor manufacturer. Fuji's motors do not require inverter on nonflammable material such as metal. assumed that the surge current is generated by
the use of output circuit filters because of their Ensure that the installation location meets the open/close of the phase-advancing capacitor in the
reinforced insulation. environmental conditions specified in "Environment" power system.
in inverter specifications. We recommend connecting a DC REACTOR to the
Torque characteristics and temperature rise
When the inverter is used to run a general-purpose inverter.
Combination with peripheral devices
motor, the temperature of the motor becomes Megger test
higher than when it is operated using a commercial Installing a molded case circuit When checking the insulation resistance of the
power supply. In the low-speed range, the cooling breaker (MCCB) inverter, use a 500V megger and follow the
effect will be weakened, so decrease the output Install a recommended molded case circuit breaker instructions contained in the Instruction Manual.
torque of the motor. If constant torque is required in (MCCB) or an earth leakage circuit breaker (ELCB)
the low-speed range, use a Fuji inverter motor or a in the primary circuit of each inverter to protect the Wiring
motor equipped with an externally powered wiring. Ensure that the circuit breaker capacity is
ventilating fan. equivalent to or lower than the recommended
Wiring distance of control circuit
When performing remote operation, use the twisted
Vibration capacity.
shield wire and limit the distance between the
When the motor is mounted to a machine, Installing a magnetic contactor (MC) inverter and the control box to 20m.
resonance may be caused by the natural in the output (secondary) circuit
frequencies, including that of the machine. If a magnetic contactor (MC) is mounted in the Wiring length between inverter and motor
Operation of a 2-pole motor at 60Hz or more may inverter's secondary circuit for switching the motor If long wiring is used between the inverter and the motor, the
cause abnormal vibration. to commercial power or for any other purpose, inverter will overheat or trip as a result of overcurrent (high-
* Study use of tier coupling or dampening rubber. ensure that both the inverter and the motor are fully frequency current flowing into the stray capacitance) in the
* It is also recommended to use the inverter jump stopped before you turn the MC on or off. Remove wires connected to the phases. Ensure that the wiring is
frequency control to avoid resonance points. the surge killer integrated with the MC. shorter than 50m. If this length must be exceeded, lower the
carrier frequency or mount an output circuit filter (OFL).
Noise Installing a magnetic contactor (MC) When wiring is longer than 50m, and sensorless vector
When an inverter is used with a general-purpose in the input (primary) circuit control or vector control with speed sensor is selected,
motor, the motor noise level is higher than that with Do not turn the magnetic contactor (MC) in the execute off-line tuning.
a commercial power supply. To reduce noise, raise primary circuit on or off more than once an hour as
carrier frequency of the inverter. High-speed an inverter fault may result. If frequent starts or Wiring size
operation at 60Hz or more can also result in more stops are required during motor operation, use Select cables with a sufficient capacity by referring
noise. FWD/REV signals. to the current value or recommended wire size.