Vous êtes sur la page 1sur 52

Fluke Calibration

Products and Services


Short Form Catalog
Precision, performance, confidence.™

Electrical

RF Temperature

Pressure

Flow

Software
Table of contents

2 Electrical
calibration 11 Temperature
calibration

DC/LF electrical calibrators...........................................5 Standard platinum resistance thermometers.......... 18


Specialty calibrators.......................................................6 ITS-90 fixed-point cells.............................................. 18
Oscilloscope calibrators.................................................7 Cell maintenance apparatus...................................... 19
Precision multimeters ...................................................7 Thermometer readouts................................................ 20
Electrical standards........................................................8 Reference PRTs..............................................................21
Thermocouples..............................................................21
Featured products
Thermistors....................................................................21
5730A Multifunction Calibrator Compact calibration baths.......................................... 22
The new gold standard in electrical calibration.
Page 3 Standard calibration baths......................................... 22
Dry-well calibrators and Micro-Baths..................... 24
6003A Three Phase Electrical Power Calibrator Infrared calibrators...................................................... 25
Three phases of power with optional energy and Thermocouple furnaces.............................................. 25
power quality in a single easy-to-use instrument.
Miscellaneous temperature calibrators.................... 25
Page 3
Featured products
9118A Thermocouple Calibration Furnace

9
High performance furnace for thermocouple
RF calibrations to 1200 °C.
calibration Page 12

RF references................................................................ 10 1586A Super-DAQ Precision


Temperature Scanner
Featured products The most accurate, flexible multi-point
temperature measurement system.
96270A 27 GHz Low Phase Noise Page 12
Reference Source
The simplest, most accurate and cost effective
single instrument for calibrating spectrum
analyzers, RF power sensors and more.
Page 10

96040A Low Phase Noise Reference Source


Simplify your RF calibration system by replacing
many of the instruments and accessories that
make up your current system.
Page 10

www.flukecal.com
26 Pressure
calibration 39 Calibration
software

Gas pressure controllers/calibrators......................... 30 Electrical and RF calibration software.....................41


High pressure controllers/calibrators....................... 31 Calibration asset management software................. 42
Reference pressure indicators................................... 31 Software support program......................................... 42
PG7000 series piston gauges..................................... 32 Temperature calibration software............................ 43
2400 series piston gauges......................................... 32 Pressure/Flow calibration software......................... 43
Specialty piston gauges.............................................. 33
Featured products
Manual pressure generation and control................ 33
MET/TEAM® Test Equipment Asset
Industrial deadweight testers.................................... 34
Management Software
Pressure comparators.................................................. 34 Powerful, flexible, scalable calibration
Pressure calibrators..................................................... 35 management software solution for managing
Air data calibration...................................................... 36 your calibration assets.
Pressure calibration systems..................................... 36 Page 40

Featured products MET/CAL® Plus Calibrator


Management Software
6270A Modular Pressure Controller/Calibrator The complete solution for managing and
The simple easy-to-maintain solution for calibrating automating your calibration workload.
a wide range of pressure gauges and sensors. Page 40
Page 27

2700G Series Reference Pressure Gauges


Best-in-class measurement performance in a
rugged, easy-to-use, economical package.

44
Page 27 Data acquisition
and general purpose test
3130 Portable Pressure Calibrator
Everything you need for accurate calibration of
pneumatic field instrumentation, in a rugged case Featured products
suitable for harsh industrial environments.
Page 27 2638A Hydra Series III Data Acquisition System
A price performance breakthrough in standalone
data acquisition system.
Page 45

37 Gas flow Fluke DAQ 6.0 Application Software


A powerful and versatile application for quick and
calibration easy configuration, data logging and analysis using
Fluke data acquisition products.
Gas Flow Standards..................................................... 38 Page 45
Primary Gas Flow Standard....................................... 38

Service programs.........................................48
Training...........................................................49

www.flukecal.com
Electrical calibration
Electrical calibration refers to the process of test (UUTs). Because these precise devices have
verifying the performance of, or adjusting, any thoroughly known performance characteristics
instrument that measures, sources, or tests compared to the UUT, performance evaluation
electrical parameters. This discipline is usually and/or calibration adjustment of the UUT to
referred to as dc and low frequency ac electrical identify or minimize errors is possible. Typically,
metrology. Principal parameters include voltage, the performance of such precision devices should
current, resistance, inductance, capacitance, be four or more times better than the UUT.
time and frequency. Other parameters, including These precision devices fall into two broad
electrical power and phase, are also in this categories. Electrical signal sources are often
segment of metrology. Ratiometric comparisons of referred to as either calibrators or standards.
similar parameters are often performed to compare Precision measurement devices are often classified
a known parameter to an unknown similar as reference digital multimeters, measurement
parameter. standards, or ratio bridges.
Electrical calibration involves the use of precise
devices that evaluate the performance of key
properties for other devices called units under

2 Electrical Calibration www.flukecal.com


Product highlights

5730A Multifunction Calibrator 6003A Three Phase Electrical Power


The new gold standard in electrical calibration Calibrator
The 5730A High Performance Multifunction Three power phases in a single easy-to-use
Calibrator is the culmination of years of engineer- instrument
ing development, customer research and industrial The 6003A Three Phase Electrical Power Calibrator
design, to bring to market the new “gold standard” is the most cost-effective way to get the superior
in multifunction calibration. Like its predeces- accuracy and performance of three independent
sors, the 5700A and 5720A calibrators, the 5730A phases in one instrument. It is an ideal solution for
calibrates a wide range of digital multimeters, up calibration laboratories, electronics manufacturers,
to long-scale 8.5 digit DMMs, as well as a wide- electric utility meter shops, and other organizations
range RF multimeters. This new model features that manufacture and maintain energy meters,
improved specifications that will help you increase power quality analyzers, and similar tools.
test uncertainty ratios (TURs) and improve test Along with providing three independent phases
confidence. of precise voltage and current, the 6003A also
• 6.5 inch VGA capacitive touchscreen with full sources power quality phenomena, including har-
color graphical user interface monics, interharmonics, flicker (modulation) and
• Menus and functions displayed in choice of nine dip/swell variations.
languages The 6003A includes measurement capabilities for
• Visual Connection Management ™ terminals guide dc voltage, dc current and frequency for measuring
cable connections outputs from power and energy transducers.
The 6003A delivers all of this functionality with
• Extended operational reliability through the use
a graphical user interface that makes it easy to
of modern analog and digital components and
learn and use.
state-of-the-art circuit board technologies
Features at a glance:
• Artifact Calibration—the process of using just
• Three phases in a single instrument
three external standards—10 V, 1 ohm and
• Simulates dc or ac electrical power and energy in
10 k ohm, to automatically adjust the entire
voltage range to 600 ac V or 280 dc V and cur-
instrument—optimizes performance to the best
rent range to 30 A per phase or 90 A combined
specified performance
• Phase shift between voltage and current chan-
• Cal Check—a process that tests all function
nels can be set from 0° to 359.99°
and ranges for any drift since the most recent
• Specifications of ± 375 ppm for power and 0.01°
calibration—provides ongoing confidence in
for phase
performance. Any output drift is measured and
• Current outputs can be isolated from ground by
evaluated it with respect to specification.
up to 450 V peak
• Compatible with 52120A and 5725A amplifiers
• Optional energy and power quality capabilities
• Full MET/CAL® compatibility with 5700A
• Built-in dc multimeter for transducer output
and 5720A procedures (MET/CAL versions 7.3
measurement
and above)
• Offers a high current adapter for applications
• 30 MHz and 50 MHz wideband output options
needing from 30 A to 90 A of current
available

www.flukecal.com Electrical Calibration 3


Selection guide
Electrical Power and Energy
Multi-Product Multifunction Oscilloscope Precision Process
Tester Calibrators and
Calibrators Calibrators Calibrators Calibrators
Calibrator Standards

Workload 5080A 5502A 5522A 5730A 9500B 5320A 6003 6100B 6105A 525B 7526A
Analog/panel meters
High burden meters
Low burden meters V dc & V ac V dc, I dc & R V dc, I dc & R
DMMs
Basic dc V accuracy 100 ppm 50 ppm 11 ppm 3.5 ppm n/a 0.10 % 375 ppm 112 ppm 42 ppm 40 ppm 40 ppm
3.5 digits V dc & V ac V dc, I dc & R V dc & V ac
(typ. ± 0.3 % dc V)

4.5 digits
(typ. ± 0.025 % dc V)

5.5 digits
(typ. ± 0.015 % dc V)

6.5 digits
(typ. ± 0.0024 % dc V)

7.5 digits
(typ. ± 12 ppm dc V)

8.5 digits
(typ. ± 3.9 ppm dc V)

Temperature/pressure
RTD simulate
RTD measure
Thermocouple
simulate
Thermocouple
measure
Pressure modules opt opt opt
Two-wire
transmitters
Oscilloscopes 1 to 5 channels
300 MHz or
200 MHz to 200 MHz 600 MHz
600 MHz 600 MHz 600 MHz std
opt opt
opt
1.1 GHz 1 GHz opt 9510 Head opt
3.2 GHz 9530 Head opt
6.4 GHz 9560 Head opt
25 ps fast edge 9550 Head opt
(14 GHz)
Safety testers
Hipot
Megohm meters MEG opt
Installation
PATs
Continuity MEG opt
Loop impedance
Leakage current
Ground bond
RCD/GFCI
Medical safety
Power/energy
Wattmeters
Harmonic analyzers PQ opt
Flicker meters PQ opt PQ opt
Phase angle meters PQ opt
Power analyzers PQ opt PQ opt
Power recorders
Secondary energy
standards
Watthour/
E opt
energy meters
Other
52120A
5500A/ 5500A/ 5500A/ 52120A Amp
Clamp meters Amp +
COIL COIL COIL + COIL opt
COIL Opt
LCR meters RC only RC only
Process calibrators
Data acquisition
Non sine waveforms
30/50 MHz WB
RF millivolt meters
opts
# of calibrator
8 11 11 5 11+ 9 8 8 9 9
functions
5522A

DC/LF Electrical
Calibrators 5730A

5730A Multifunction
Calibrator
The new gold standard in
electrical calibration.
• The next generation high-
performance multifunction
calibrator
• Support instruments of up to 5502A 5080A
8.5 digits in measurement
performance
5522A Multi-Product 5080A High Compliance
• Artifact Calibration permits
Calibrator Multi-Product Calibrator
the lowest cost of support
and highest confidence in Robust, transportable wide work- Solutions for your analog and
performance load coverage. digital workload.
• New internal printed circuit • Calibrates a wide variety • High compliance for difficult-
boards with upgraded digital of electrical test equipment to-calibrate analog instruments
technology with more than 14 functional • Robust protection circuits
• 6.5 inch VGA capacitive capabilities prevent costly damage from
touchscreen with full color • Accuracies intended to support operator error
graphical user interface DMMs to 6.5 digits • Calibrates a wide workload,
• Menus and functions dis- • Robust protection circuits including analog meters and
played in choice of nine prevent costly damage from 3.5 and 4.5 digit DMMs
languages operator error • Options for oscilloscope and
• Optional wideband outputs • Optional oscilloscope calibra- megohm meter calibration
to 30 or 50 MHz tion to 1100 MHz
• Easy to transport

5502A Multi-Product
Calibrator
Robust, transportable solution to
match your workload and budget.
• Calibrates a wide variety of
electrical test equipment
• Robust protection circuits
prevent costly damage from
operator error
• Ergonomically designed
carrying handles
• Rugged optional case with
built-in handles and wheels
and removable front/rear
access doors
• Optional oscilloscope
calibration to 600 MHz

www.flukecal.com Electrical Calibration 5


6105A/6100B 52120A

7526A 5725A 6135A/PMU

6003A Three Phase


Electrical Power Calibrator
Three power phases in a single
easy-to-use instrument.
• Cost effective
• Easy to use
• Simulates dc or ac electrical
5320A 6003A power and energy in voltage
range to 600 ac V or 280 dc V
Specialty 52120A Transconductance and current range to 30 A per
Amplifier phase or 90 A combined
Calibrators Test and calibrate power stan- • Phase shift between voltage
dards, power and energy meters, and current channels can be
6105A/6100B Electrical PQ analyzers, high-current clamp set from 0° to 359.99°
Power Standards meters and Rogowski coils.
The most accurate, compre- Delivers: 6135A/PMU Phasor
hensive and flexible sources • 120 A stand-alone Measurement Unit Calibrator
of electrical power quality and • 240 A or 360 A with parallel
Fast, automated, IEEE C37
energy signals. operation
118.1-2011-compliant PMU
• Power calibration with volt- • 3000 A or 6000 A with acces-
calibrations. System includes:
age to 1008 V and current to sory coils
• PMU control unit
21 amps, and optionally up to • Industry-leading amplifier
• GPS receiver
80 amps accuracy:
• PMU test and calibration
• Voltage and current accuracies – 100 PPM dc to 850 Hz
software
better than 0.005 % (50 ppm) – 120 PPM dc and 260 PPM ac
• Fluke 6135 Electrical Power
• Current to voltage phase in stand-alone operation
Standard
accuracy of 0.003 ° • Frequency capability, dc to
• Configured server PC
• Programmable harmonic distor- 10 kHz
tion up to 100 harmonics
• Includes other power quality 5320A Multifunction
7526A Precision Process
testing phenomena Electrical Tester Calibrator
Calibrator
• Complex measurements gener- Verify and calibrate electrical test
Best balance of economy and
ating a wide variety of signals tools with a single instrument.
accuracy for calibration of tem-
• Calibrate megohm meters, earth
perature and pressure process
5725A Amplifier resistance testers, ground bond
measurement instrumentation.
testers, hipots, installation
The Fluke 5725A Amplifier is a • Sources and measures dc volt-
testers and many more types of
companion to the 57XX Series age, current, resistance
electrical safety testers
calibrators. • Measures and simulates RTDs
• Uses less bench space than
• Extends the calibrators’ alter- and thermocouples
custom solutions
nating volt-hertz product to • Measures pressure using Fluke
• Built-in graphical calibration
1100 V at 30 kHz and 750 V at 700/525A-P pressure modules
help guide
100 kHz • Includes 24 V dc loop power
• LAN, GPIB, RS-232 interfaces
• Increases maximum direct and supply, automated switch-test
for PC based automation
alternating current to 11 A function and measures 4 mA to
20 mA

6 Electrical Calibration www.flukecal.com


525B Temperature/Pressure
Calibrator
Superior accuracy and function-
ality in an economical benchtop
package.
• A calibrator to address process
industry instrumentation
• Simulates and measures all
ANSI thermocouples, as well
as L and U types, and provides 525B 9500B
cold junction compensation
to enable calibration of a
wide variety of thermocouple
instrumentation
• Direct input for storage of
ITS-90 RTD constants
• RTD source uncertainties
to 0.03 °C
55XX 8508A
Oscilloscope
Calibrators
9500B Oscilloscope
Calibrator
The highest performance, fully
automated, upgradeable oscillo-
8845A/8846A 8808A
scope calibration workstation.
• Full automation provides totally
hands-free calibration
• Bandwidths of 600 MHz, Precision Multimeters
1000 MHz, 3200 MHz, and
6400 MHz 8508A Reference Multimeter 8845A/8846A Precision
• A fast edge of 25 ps to address Reference standard accuracy Multimeters
bandwidths up to 14 GHz and stability, in one functionally Precision and versatility for bench
• Connect up to five channels versatile, easy-to-use solution. or systems applications.
simultaneously • 8.5 digit resolution, exceptional • 6.5 digit resolution
linearity and low noise and • Basic V dc accuracy of up to
55XX Series Oscilloscope stability 0.0024 %
Calibration Options • Optional electronic front/ • Dual display, showing two
Options for the 5502A and 5522A rear inputs with unique ratio different measurements at once
calibrators add capabilities to measurement option
calibrate your digital and analog • Broad range of measurement 8808A Digital Multimeter
oscilloscopes with any of three capabilities
• 365 day stability as low as Versatile multimeter for manufac-
different ranges of bandwidths. turing, development and service
• Leveled sine wave generator 2.7 ppm, 24-hour stability of
0.5 ppm, transfer uncertainty applications.
with optional bandwidths • 5.5 digit resolution
of 300 MHz, 600 MHz and of 0.12 ppm
• Basic V dc accuracy of 0.015 %
1100 MHz for verifying • Dual display, showing two
oscilloscope bandwidth different measurements at once
• DC and square wave voltage
generators for calibrating
voltage gain
• Horizontal time base calibra-
tion functions
• Edge source including a 300 ps
fast edge with low aberrations
for verifying dynamic response
• Fast edge risetime pulse
generator (< 1 ns) for checking
pulse response

www.flukecal.com Electrical Calibration 7


732B/734A 792A 5790B 742A

A40B A40/A40A 752A 720A

Electrical
Standards
732B/734A DC Reference
and Transfer Standards
910/910R 908/909
The simple way to maintain and
disseminate your volt.
• A primary standard for trace-
ability of dc voltage to better 742A Resistance Standard 720A Kelvin-Varley Divider
than 1 ppm High accuracy working standard A primary standard for ratio
• Complete mechanical and elec- for on-site resistance calibration. measurements.
trical independence of each of • Small and rugged standard • 0.1 ppm resolution, seven
its four standards (734A) resistors with six-month stabil- decades
• Battery powered for easy ities to 2.5 ppm • 0.1 ppm of input absolute
shipping • Open air use so no oil or air linearity
baths required • Built-in self-calibration bridge
792A AC/DC Transfer • 18 °C to 28 °C operating range
Standard • Standard values from 1 ohm to 910/910R GPS Controlled
100 Megohms Frequency Standard
Support for your most demanding
ac traceability requirements. A40B Series Precision Cesium controlled frequency
• A primary standard that is Current Shunts standard that uses GPS technol-
accurate, fast and easy to use ogy and connectivity to provide
• Fully traceable performance Precision, low inductance shunts
primary standard traceability
with ac/dc difference to better for dc and ac current metrology.
from any location.
than 10 ppm • Simplifies calibration/verifica-
• Unique traceability feature
• Nine ranges from 22 mV to tion of precision calibrators
means no more re-calibrations
1000 V (with external range and current sources
• Two high-stability models to
resistor) • Shunts sized for current from
meet your application and fit
1 mA to 100 A
your budget
• Usable from dc to 100 kHz
5790B AC Measurement • Built-in rubidium atomic clock
• Ultra low phase shift to sup-
Standard (910R)
port power quality instrument
• Up to 13 outputs, maximizing
Easiest way to make precision ac metrology
cost efficiency
measurements
• AC voltage measurement uncer- A40/A40A Current Shunts
tainties as low as ± 24 ppm • AC current transfer measure-
908/909 Frequency
• Works with A40B shunts for ments from 2.5 mA to 20 A References
making precise absolute and • Frequency between 5 Hz to Stable frequency references for
relative current measurements 100 kHz test systems and calibration labs.
without requiring manual • Accurate reference “atomic
current value calculations 752A Reference Divider clock” in automated test
• 30 MHz and 50 MHz wideband Setting the standard for ratio systems
range options accuracy and ease of use. • Affordable and very cost
• Statistics and peak-to-peak • Key standard for calibrating effective
waveform functions 57xx Series Calibrators • Designed for portability with
• Intuitive graphical interface • 10:1 and 100:1 divider outputs optional carrying case
• Visual Connection Manage- • Output uncertainty 0.2 ppm
ment™ terminals that light up and 0.5 ppm
to show the active terminals • Built-in calibration bridge

8 Electrical Calibration www.flukecal.com


RF calibration
RF and microwave calibration refers to the process Precision devices that are commonly used in RF
of verifying the performance of, or adjusting/ and microwave calibration fall broadly into four
deriving corrections for, any instrument or categories:
component that will be used in the measurement
Sourcing instruments. Reference signals and/
or testing of RF and microwave parameters.
or modulation sources, frequency references,
This discipline is usually referred to as RF and
pulse or arbitrary waveform generators, reference
microwave metrology. Principal parameters include
attenuators.
RF voltage, RF power, impedance, modulation,
distortion, time, frequency and phase. High Measuring instruments. Power sensors, spectrum
dynamic range ratiometric comparisons are analyzers, measuring receivers, oscilloscopes, RF
often performed and results are expressed in the voltmeters, frequency counters.
logarithmic “dB” form. Source-measure instruments. Vector or scalar
As with any other calibration, RF and microwave network analyzers.
calibration compares a device or unit under test
(DUT or UUT) to a traceably calibrated standard or Precision components
reference device. The process typically involves • Power splitters, power dividers or couplers,
comparing a measuring UUT to a reference source; attenuating pads
a sourcing UUT with a measuring reference; or • Inter-series, polarity or sacrificial cables and
quite commonly a measuring UUT with a measuring adapters
reference, using a stable but unknown source. • Short, open, load or sliding terminators
In each case, the uncertainty or stability of the • Reflection bridges or directional couplers
reference should significantly exceed the specified
performance of the device or unit under test.
RF metrologists typically look for performance
margins of 4:1, however, test uncertainty ratios
lower than this usual target are more frequently
encountered in RF than in other calibration
disciplines. Conversion from logarithmic (dB)
to linear units is recommended practice when
combining uncertainty contributions and
considering test uncertainty ratios.

www.flukecal.com RF Calibration 9
96270A 96040A

RF References
96270A 27 GHz Low Phase 96040A Low Phase Noise
Noise Reference Source Reference Source
The simplest, most accurate and Simplify your RF calibration
cost effective single instrument system by replacing many of the
for calibrating spectrum analyz- instruments and accessories that
ers, RF power sensors and more. make up your current system.
• “Self-characterization” lets you • Covers a broad range of RF
avoid calculating correction calibration workload
factors for each component in • Reduces the number of instru-
the signal delivery system ments and interconnections
• “What you set is what you get” required for your RF calibra-
accurate signal delivery direct tion system
to the UUT input up to 27 GHz • “What you set is what you
• Covers a broad range of RF get” accurate signal delivery
calibration workload direct to the UUT input
• Reduces the number of instru- • Integrated 50 MHz frequency
ments and interconnections counter eliminates need for an
required for your RF calibration additional instrument
system • Calibration-specific interface
• Integrated 300 MHz frequency simplifies technician tasks
counter and dual power meter • Simplifies uncertainty calcula-
readout eliminate need for tions by delivering known
additional instruments signals direct to the unit
• Calibration-specific interface under test (UUT)
simplifies technician tasks • Lowers RF system mainte-
• Simplifies uncertainty nance costs
calculations • With automation, reduces
• Lowers RF system maintenance spectrum analyzer calibration
costs times by as much as 50 %
• With automation, reduces over manual methods
spectrum analyzer calibration
times by as much as 50 % over
manual methods

10 RF Calibration www.flukecal.com
www.flukecal.com
Temperature calibration

Temperature calibration refers to the calibration general categories of heat sources: industrial heat
of any device used in a system that measures sources (dry-well calibrators, Micro-Baths, etc.) for
temperature. Most importantly, this usually means field use; fluid baths and thermocouple furnaces for
the temperature sensor, itself, which is typically a laboratory use; and fixed-point cells for “primary”
platinum resistance thermometer (PRT or PT-100), calibrations. Fluke Calibration also offers a variety
thermistor, or thermocouple. Readings from these of reference thermometers, including SPRTs, and
thermometers are made by “thermometer readout” thermometer readout instruments.
devices which measure their electrical outputs In addition, Fluke Calibration provides laboratory
and convert them to temperature according to the and field solutions for calibrating the electronics
International Temperature Scale of 1990 (ITS-90). used in temperature measurement circuits.
Thermometers are typically calibrated by placing
them in a stable temperature environment (heat
source) and comparing their output to that of a
calibrated “reference thermometer” or “standard
thermometer.” Fluke Calibration provides three

www.flukecal.com Temperature Calibration 11


Product highlights

9118A Thermocouple Calibration 1586A Super-DAQ Precision


Furnace Temperature Scanner
High performance furnace for thermocouple The most accurate, flexible temperature data
calibrations to 1200 °C acquisition system
The 9118A Thermocouple Calibration Furnace is The 1586A is ideal for benchtop calibration of
a horizontal, open-ended tube furnace with a temperature sensors in secondary calibration
temperature range of 300 °C to 1200 °C. It is used labs, as well as temperature data acquisition
for comparison calibration of noble and base-metal applications in industries such as pharmaceutical,
thermocouples by secondary high-temperature labs bio-technology, aerospace, food and energy where
and instrument shops in industries such as aero- accurate temperature measurements are critical.
space, automotive, energy, metals, and plastics. • Flexible configuration for the benchtop or
The 9118A is the most accurate, reliable, and flex- factory using the DAQ-STAQ Multiplexer or
ible furnace in its class, meeting the demanding internal High-Capacity Module
requirements of high-temperature thermocouple • Measure thermocouples, PRTs, thermistors, dc V,
calibration. dc I, and resistance
Seven key features set the 9118A apart from • Best-in-class temperature measurement
other high-temperature calibration furnaces: accuracy:
1. Wide temperature range spanning most high- – PRTs: ± 0.005 °C (using DAQ-STAQ Multiplexer)
temperature applications – T hermocouples: ± 0.29 °C (using DAQ-STAQ
2. Removable isothermal block allows flexible Multiplexer and internal CJC for type K at 0 °C)
configuration for calibrating many thermocouple – Thermistors: ± 0.002 °C
types • Connect up to 40 isolated inputs
3. Best-in-class temperature stability and unifor- • Scan speed of up to 10 channels per second
mity for calibration accuracy • Four modes of operation: Scan, Monitor,
4. Automated setpoint control for improved lab Measure, DMM
productivity • Real-time color trending—chart up to four
5. Non-metallic block helps minimize thermocouple channels simultaneously
contamination • Controls Fluke Calibration temperature sources
6. Deep immersion depth to support most thermo- such as dry-wells, furnaces or Micro-Baths for
couple calibrations automated calibration routines
7. Dynamic heater control and cutouts for reliability • MX + B scaling and channel offset zero function
and safety • Built-in data security levels

12 Temperature Calibration www.flukecal.com


Selection guides
Primary standards
Standard platinum resistance thermometers (SPRTs)
Model RTPW Description
5681 25.5 Ω –200 °C to 670 °C, quartz sheath
5683 25.5 Ω –200 °C to 480 °C, quartz sheath
5684 0.25 Ω 0 °C to 1070 °C, quartz sheath
5685 2.5 Ω 0 °C to 1070 °C, quartz sheath
5698 25.5 Ω –200 °C to 670 °C, working standard, quartz sheath
5699 25.5 Ω –200 °C to 670 °C, high temperature, metal sheath
5686 25.5 Ω –260 °C to 232 °C, glass capsule

ITS-90 fixed-point cells


Model Description Temperature Model Features/use

Triple point of water cells Maintenance apparatus


5901A-G TPW Cell, 12 mm ID with handle, glass shell 0.01 °C 7012 Maintains: triple point of water and gallium cells.
Comparisons: –10 °C to 110 °C.
5901A-Q TPW Cell, 12 mm ID with handle, quartz shell 0.01 °C
7037 Maintains: triple point of water and gallium cells.
5901C-G TPW Cell, 13.6 mm ID with handle, glass shell 0.01 °C Comparisons: –40 °C to 110 °C.
5901C-Q TPW Cell, 13.6 mm ID with handle, quartz shell 0.01 °C 7312 Maintains: two TPW cells. Compact size, runs quietly.
5901D-G TPW Cell, 12 mm ID, glass shell 0.01 °C Comparisons: –5 °C to 110 °C.

5901D-Q TPW Cell, 12 mm ID, quartz shell 0.01 °C 7341 Maintains: triple point of mercury cell.
Comparisons: –45 °C to 150 °C.
5901B-G TPW Cell, mini, glass shell 0.01 °C
9210 Maintains: mini triple point of water.
Standard size fixed-point cells Comparisons: –10 °C to 125 °C.

5900E TP mercury, SST –38.8344 °C 9230 Maintains: stainless steel gallium cell.
Comparisons: 15 °C to 35 °C.
5904 Freezing point of indium 156.5985 °C
9260 Maintains: indium, tin, zinc, and aluminum cells.
5905 Freezing point of tin 231.928 °C Comparisons: 50 °C to 680 °C.
5906 Freezing point of zinc 419.527 °C 9114 Maintains: indium, tin, zinc, and aluminum cells.
Comparisons: 100 °C to 680 °C.
5907 Freezing point of aluminum 660.323 °C
9115A Maintains: aluminum and silver cells.
5908 Freezing point of silver 961.78 °C
Comparisons: 550 °C to 1000 °C.
5909 Freezing point of copper 1084.62 °C
9116A Maintains: aluminum, silver, gold, and copper cells.
5924 Open freezing point of indium 156.5985 °C Comparisons: 400 °C to 1100 °C.

5925 Open freezing point of tin 231.928 °C 9117 Anneals SPRTs, HTPRTs, and thermocouples to 1100 °C.
Protects them against contamination from metal ions.
5926 Open freezing point of zinc 419.527 °C
Boiling point of liquid nitrogen
5927A Open freezing point of aluminum 660.323 °C
7196 Affordable substitute for a triple point of argon system.
5928 Open freezing point of silver 961.78 °C Provides for low-temperature comparison calibrations at
5929 Open freezing point of copper 1084.62 °C approximately –196 °C with uncertainties of 2 mK.

5943 Melting point of gallium, SST 29.7646 °C Triple point of argon system
5960A Lowest uncertainty for any commercially available triple
Mini triple point of water and fixed-point cells point of argon system.
5901B Mini triple point of water 0.01 °C
Standard resistors
5914A Mini freezing point of indium 156.5985 °C
742A Excellent performance without oil or air baths.
5915A Mini freezing point of tin 231.928 °C Values from 1 ohm to 19 megohm.
5916A Mini freezing point of zinc 419.527 °C 5430 Highest stability oil-filled resistors (< 2 ppm/year drift).
AC cal uncertainty to 3 ppm.
5917A Mini freezing point of aluminum 660.323 °C
5918A Mini freezing point of silver 961.78 °C
5919A Mini freezing point of copper 1084.62 °C
5944 Mini freezing point of indium, metal cased 156.5985 °C
5945 Mini freezing point of tin, metal cased 231.928 °C
5946 Mini freezing point of zinc, metal cased 419.527 °C
5947 Mini freezing point of aluminum, metal cased 660.323 °C

www.flukecal.com Temperature Calibration 13


Thermometer readouts
Intrinsically safe thermometers
1551A Ex 100 Ω thin-film RTD –50 °C to 160 °C Accuracy of ± 0.05 °C (± 0.09 °F) over full range.
(–58 °F to 320 °F) Intrinsically safe (ATEX and IECEx compliant).
1552A Ex 100 Ω wire-wound PRT –80 °C to 300 °C Two models to choose from (-50 °C to 160 °C or -80 °C to 300 °C)
(–112 °F to 572 °F)
Precision digital thermometer readouts
Model Probe types Accuracy at 0 °C Features
Tweener
1502A PRTs ± 0.006 °C Resolution of 0.001 °C and accuracy to match; uses ITS-90, IPTS-68, CVD,
or DIN (IEC 751) conversions
1504 Thermistors ± 0.002 °C Reads thermistors from 0 to 500 KW; uses Steinhart-Hart and CVD
Handheld
1523 PRTs, Thermistors, ± 0.015 °C (PRTs) Battery-powered, handheld reference thermometer; INFO-CON connector
Thermocoouples reads coefficients without programming; saves 25 readings on demand;
graphs trends
1524 PRTs, Thermistors, ± 0.015 °C (PRTs) Handheld reference thermometer same as 1523 but with inputs for two
Thermocoouples thermometers; logs up to 15,000 readings and stores 25 more on demand
Chub-E4
1529 PRTs, Thermistors, ± 0.006 °C (PRTs) Four channels can all be measured simultaneously; battery-powered; logs
Thermocouples up to 8,000 readings; flexible display
Super-Thermometers
1594A SPRTs, PRTs, Thermistors ± 0.00006 °C Ratio accuracy of 0.8 ppm; temperature-controlled internal reference
resistors; six input channels
1595A SPRTs, PRTs, Thermistors ± 0.000015 °C Ratio accuracy of 0.2 ppm; Ratio Self-Calibration; automated zero-power
measurements
Multi-channel
1586A PRTs, Thermistors, ± 0.005 °C (PRTs) 40 channels with scan rate of 10 channels per second
Thermocouples
1560 Accepts any combination of the modules below; all are easily added to and removed from the 1560 Black Stack base
2560 SPRTs, PRTs ± 0.005 °C 2 channels of 25W or 100W PRTs
2561 HTPRTs ± 0.013 °C 2 channels to 1200 °C
2562 PRTs ± 0.01 °C 8 channels of 2-, 3-, or 4-wire RTDs
2563 Thermistors ± 0.0013 °C 2 channels of resolution to 0.0001 °C
2564 Thermistors ± 0.0025 °C 8 channels for data acquisition
2565 Thermocouples ± 0.05 °C Reads most TC types with 0.0001 mV resolution
2566 Thermocouples ± 0.1 °C Reads any combination up to 12 channels of virtually any type of TC
2567 1000 Ω PRTs ± 0.006 °C 2 channels of high-resistance PRTs
2568 1000 Ω PRTs ± 0.01 °C 8 channels of high-resistance PRTs
Thermo-hygrometer
1620A The “DewK” Thermo- Two channels measure ambient temperature to ± 0.125 °C and %RH to ±1.5 %. Onboard
Hygrometer memory holds up to two years of time/date-stamped readings. Visual and audio alarms.
Detachable sensors contain their own calibration data for easy recalibrations. Ethernet and
wireless capabilities.

14 Temperature Calibration www.flukecal.com


Thermometer probes
Platinum resistance thermometers (PRTs)
Model Range Size Basic Accuracy†
Secondary standard PRT
5608-9-X –200 °C to 500 °C 229 mm x 3.18 mm (9 in x 0.125 in)
5608-12-X –200 °C to 500 °C 305 mm x 3.18 mm (12 in x 0.125 in)
5609-12-X –200 °C to 670 °C 305 mm x 6.35 mm (12 in x 0.25 in)
5609-15-X –200 °C to 670 °C 381 mm x 6.35 mm (15 in x 0.25 in) Select from available
5609-20-X –200 °C to 670 °C 508 mm x 6.35 mm (20 in x 0.25 in) calibration options
5609-300-X –200 °C to 670 °C 300 mm x 6 mm (11.81 in x 0.24 in)
5609-400-X –200 °C to 670 °C 400 mm x 6 mm (15.75 in x 0.24 in)
5609-500-X –200 °C to 670 °C 500 mm x 6 mm (19.69 in x 0.24 in)
5626 –200 °C to 661 °C 305 or 381 mm x 6.35 mm (12 or 15 in x 0.25 in) ± 0.007 °C at 0 °C
5628 –200 °C to 661 °C 305 or 381 mm x 6.35 mm (12 or 15 in x 0.25 in) ± 0.006 °C at 0 °C
Secondary reference PRT
5616-12 –200 °C to 420 °C 298 mm x 6.35 mm (11.73 in x 0.25 in) ± 0.010 °C at 0.010 °C
5615-6 –200 °C to 300 °C 152 mm x 4.76 mm (6 in x 0.19 in) ± 0.013 °C at 0.010 °C
5615-9 –200 °C to 420 °C 229 mm x 4.76 mm (9 in x 0.19 in) ± 0.013 °C at 0.010 °C
5615-12 –200 °C to 420 °C 305 mm x 6.35 mm (12 in x 0.25 in) ± 0.013 °C at 0.010 °C
Precision industrial PRT
5627A-6 –200 °C to 300 °C 152 mm x 4.7 mm (6 in x 0.19 in) ± 0.05 °C at 0 °C
5627A-9 –200 °C to 300 °C 229 mm x 4.7 mm (9 in x 0.19 in) ± 0.05 °C at 0 °C
5627A-12 –200 °C to 420 °C 305 mm x 6.35 mm (12 in x 0.25 in) ± 0.05 °C at 0 °C
Fast response PRT
5622-05 –200 °C to 350 °C 100 mm x 0.5 mm (3.94 in x 0.02 in) ± 0.04 °C at 0 °C
5622-10 –200 °C to 350 °C 100 mm x 1.0 mm (3.94 in x 0.04 in) ± 0.04 °C at 0 °C
5622-16 –200 °C to 350 °C 200 mm x 1.6 mm (7.87 in x 0.06 in) ± 0.04 °C at 0 °C
5622-32 –200 °C to 350 °C 200 mm x 3.2 mm (7.87 in x 0.125 in) ± 0.04 °C at 0 °C
Small diameter industrial PRTs
5618B-6 –200 °C to 300 °C 152 mm x 3.2 mm (6 in x 0.125 in) ± 0.05 °C
5618B-9 –200 °C to 500 °C 229 mm x 3.2 mm (9 in x 0.125 in) ± 0.05 °C
5618B-12 –200 °C to 500 °C 305 mm x 3.2 mm (12 in x 0.125 in) ± 0.05 °C
Full immersion PRTs
5606 Immersion PRT –200 °C to 160 °C 50 mm x 3.2 mm (1.97 in x 0.125 in) ± 0.05 °C
5623B Freezer Probe –100 °C to 156 °C 152 mm x 6.35 mm (6 in x 0.25 in) ± 0.05 °C
High temperature PRT
5624 0 °C to 1000 °C 508 mm x 6.35 mm (20 in x 0.25 in) ± 0.055 °C
Thermistors
Standards
5640 0 °C to 60 °C 229 mm x 6.35 mm (9 in x 0.25 in) ± 0.0015 °C
5641 0 °C to 60 °C 114 mm x 3.2 mm (4.5 in x 0.125 in) ± 0.001 °C
5642 0 °C to 60 °C 229 mm x 3.2 mm (9 in x 0.125 in) ± 0.001 °C
5643 0 °C to 100 °C 114 mm x 3.2 mm (4.5 in x 0.125 in) ± 0.0025 °C
5644 0 °C to 100 °C 229 mm x 3.2 mm (9 in x 0.125 in) ± 0.0025 °C
Secondary probes
5610 0 °C to 100 °C 152 or 229 mm x 3.2 mm (6 or 9 in x 0.125 in) ± 0.01 °C
5611A 0 °C to 100 °C 1.5 mm (0.06 in) tip dia. ± 0.01 °C
5611T 0 °C to 100 °C 28 mm x 3 mm (1.1 in x 0.12 in) ± 0.01 °C
5665 0 °C to 100 °C 76 mm x 3.2 mm (3 in x 0.125 in) ± 0.01 °C
Thermocouples
Type R and S standards
5649/5650-20 0 °C to 1450 °C 508 mm x 6.35 mm (20 in x 0.25 in) ± 0.7 °C at 1100 °C
5649/5650-20C 0 °C to 1450 °C 508 mm x 6.35 mm (20 in x 0.25 in) ± 0.7 °C at 1100 °C
5649/5650-25 0 °C to 1450 °C 635 mm x 6.35 mm (25 in x 0.25 in) ± 0.7 °C at 1100 °C
5649/5650-25C 0 °C to 1450 °C 635 mm x 6.35 mm (25 in x 0.25 in) ± 0.7 °C at 1100 °C
†“Basic Accuracy” includes calibration uncertainty and short-term repeatability. It does not include long-term drift.

www.flukecal.com Temperature Calibration 15


Calibration baths
Compact calibration baths
Model Range Stability Depth
6330 35 °C to 300 °C ± 0.005 °C at 100 °C
234 mm (9.25 in)
(95 °F to 572 °F) ± 0.015 °C at 300 °C
7320 –20 °C to 150 °C ± 0.005 °C at –20 °C
234 mm (9.25 in)
(-4 °F to 302 °F) ± 0.005 °C at 25 °C
7340 –40 °C to 150 °C ± 0.005 °C at –40 °C
234 mm (9.25 in)
(-40 °F to 302 °F) ± 0.005 °C at 25 °C
7380 –80 °C to 100 °C ± 0.006 °C at –80 °C
178 mm (7 in)
(-112 °F to 212 °F) ± 0.010 °C at 0 °C
6331 35 °C to 300 °C ± 0.015 °C at 300 °C
457 mm (18 in)
(95 °F to 572 °F) ± 0.005 °C at –20 °C
7321 –20 °C to 150 °C ± 0.005 °C at 25 °C
457 mm (18 in)
(-4 °F to 302 °F) ± 0.005 °C at –40 °C
7341 –45 °C to 150 °C ± 0.005 °C at –40 °C
457 mm (18 in)
(-49 °F to 302 °F) ± 0.005 °C at 25 °C
7381 –80 °C to 110 °C ± 0.006 °C at –80 °C 457 mm (18 in)
(-112 °F to 230 °F) ± 0.005 °C at 0 °C
Standard size calibration baths
7080 –80 °C to 110 °C ± 0.0025 °C at –80 °C 305 mm (12 in)
(-112 °F to 230 °F) ± 0.0015 °C at 25 °C
7008 –5 °C to 110 °C ± 0.0007 °C at 25 °C 331 mm (13 in)
(23 °F to 230 °F) ± 0.0008 °C at 0 °C
7011 –10 °C to 110 °C ± 0.0008 °C at 25 °C 305 mm (12 in)
(14 °F to 230 °F) ± 0.0008 °C at 0 °C
7040 –40 °C to 110 °C ± 0.0015 °C at 25 °C 305 mm (12 in)
(-40 °F to 230 °F) ± 0.001 °C at 40 °C
6020 40 °C to 300 °C ± 0.005 °C at 300 °C 305 mm (12 in)
(104 °F to 572 °F) ± 0.001 °C at 40 °C
6022 40 °C to 300 °C ± 0.005 °C at 300 °C 464 mm (18.25 in)
(104 °F to 572 °F) ± 0.001 °C at 40 °C
6024 40 °C to 300 °C ± 0.005 °C at 300 °C 337 mm (13.25 in)
(104 °F to 572 °F) ± 0.002 °C at 200 °C
6050H 180 °C to 550 °C ± 0.007 °C at 500 °C 305 mm (12 in)
(356 °F to 1022 °F) ± 0.006 °C at –80 °C
Other
Item Description
Bath Stands, rods, and clamps to suspend and support your probes and thermometers.
accessories
Bath fluids Silicone oils, salt, and cold fluids in convenient, small quantities.
Rosemount Model 7900 controller designed by Hart integrates the features of Hart’s 2100 controller and can
bath be used in place of the Rosemount 915 controller with Rosemount-designed baths.
controllers
Fluke Model 2100 and 2200 controllers can be integrated with homemade baths or other heat sources
Calibration to achieve performance levels approaching Fluke Calibration baths.
bath
controllers

16 Temperature Calibration www.flukecal.com


Industrial temperature calibrators
Field metrology wells
Model Range Accuracy
9190A -95 °C to 140 °C (-139 °F to 284 °F) ± 0.2 °C
9142 –25 °C to 150 °C (-13 °F to 302 °F) ± 0.2 °C
9143 33 °C to 350 °C (91 °F to 662 °F) ± 0.2 °C
9144 50 °C to 660 °C (122 °F to 1220 °F) ± 0.35 °C at 50 °C
± 0.35 °C at 420 °C
± 0.5 °C at 660 °C
Micro-Baths
6102 35 °C to 200 °C (95 °F to 392 °F) ± 0.25 °C
7102 –5 °C to 125 °C (23 °F to 257 °F) ± 0.25 °C
7103 –30 °C to 125 °C (–22 °F to 257 °F) ± 0.25 °C
Handheld dry-wells
9100S 35 °C to 375 °C (95 °F to 707 °F) ± 0.25 °C at 100 °C
± 0.5 °C at 375 °C
9102S –10 °C to 122 °C (14 °F to 252 °F) ± 0.25 °C
Field dry-wells
9009 –15 °C to 350 °C (5 °F to 662 °F) Cold block: ± 0.2 °C
Hot block: ± 0.6 °C
9103 –25 °C to 140 °C (–13 °F to 284 °F) ± 0.25 °C
9140 35 °C to 350 °C (95 °F to 662 °F) ± 0.5 °C

Infrared calibrators
4180 –15 °C to 120 °C (5 °F to 248 °F) ± 0.40 °C at –15 °C
± 0.40 °C at 0 °C
± 0.50 °C at 50 °C
± 0.50 °C at 100 °C
± 0.55 °C at 120 °C
4181 35 °C to 500 °C (95 °F to 932 °F) ± 0.35 °C at 35 °C
± 0.50 °C at 100 °C
± 0.70 °C at 200 °C
± 1.20 °C at 350 °C
± 1.60 °C at 500 °C
9132 50 °C to 500 °C (122 °F to 932 °F) ± 0.5 °C at 100 °C
± 0.8 °C at 500 °C
9133 –30 °C to 150 °C (–22 °F to 302 °F) ± 0.4 °C
Metrology Wells
9170 –45 °C to 140 °C (–49 °F to 284 °F) ± 0.1 °C
9171 –30 °C to 155 °C (–22 °F to 311 °F) ± 0.1 °C
9172 35 °C to 425 °C (95 °F to 797 °F) ± 0.1 °C at 100 °C
± 0.15 °C at 225 °C
± 0.2 °C at 425 °C
9173 50 °C to 700 °C (122 °F to 1292 °F) ± 0.2 °C at 425 °C
± 0.25 °C at 660 °C
Zero point dry-well
9101 0 °C (32 °F) ± 0.05 °C
Dual block dry-well
9011 50 °C to 670 °C (122 °F to 1238 °F) ± 0.2 °C at 50 °C
± 0.4 °C at 400 °C
± 0.65 °C at 600 °C
–30 °C to 140 °C (–22 °F to 284 °F ) ± 0.25 °C (insert wells)
± 0.65 °C (fixed wells)
Thermocouple furnaces
9150 150 °C to 1200 °C (302 °F to 2192 °F) ± 5 °C
9118A 300 °C to 1200 °C (572 °F to 2192 °F) ± 5 °C

www.flukecal.com Temperature Calibration 17


5681, 5683, 5684, and 5685 5698-25
ITS-90

5686-B 5699 5901

Standard ITS-90 fixed-


Mini Fixed-Point Cells
platinum point cells
resistance 5901 Triple Point of Water
thermometers Cells
Must-have, primary temperature
(SPRTs) standards.
• Easy-to-use, inexpensive
5681, 5683, 5684, and
standard with uncertainty
5685 Quartz-Sheath SPRTs
better than ± 0.0001 °C
The performance you expect from • Four sizes and two shells
world-class SPRTs. (glass and quartz) to choose
• Drift rates as low as 0.0005 K from
• Proprietary gas mixtures • Isotopic composition of Vienna
ensures high stability Standard Mean Ocean Water
• Most experienced SPRT design
team in the business
ITS-90 Fixed-Point Cells
Best cell uncertainties commer-
5698-25 Working Standard
cially available.
SPRT • Every ITS-90 fixed point
High performance-to-price ratio. available from mercury to
• Conforms to ITS-90 SPRT copper
Guidelines • Plateaus last days (gallium for
• Drift rate typically 0.003 °C weeks and TPW for months)
• Calibration options by fixed • Manufactured and tested by
point Fluke Calibration’s primary
standards scientists
5686-B Glass Capsule SPRT
Designed for metrology work Mini Fixed-Point Cells
requiring small SPRTs. Least expensive, easiest-to-use
• Temperatures from -260 °C fixed-point standards.
(13 K) to 232 °C • Lower uncertainties than com-
• Stability typically 0.001 °C parison calibrations
over 100 °C range • All ITS-90 fixed points from
• Miniature capsule package TPW to copper
eliminates stem conduction • Reduced equipment and
annual recalibration costs
5699 High-Temperature
Metal-Sheath SPRT
Affordable working standard
SPRT.
• Range to aluminum point
(660 °C)
• Inconel™ sheaths guard against
contamination of sensor
• Drift rates less than 8 mK/year

18 Temperature Calibration www.flukecal.com


9114, 9115A, 9116A
9117 7196B

Cell maintenance apparatus


9114, 9115A, 9116A Freeze- 7012/7312 Triple Point of
Point Furnaces Water Maintenance Baths
Designed for maximum-length Keep your cells up and running
plateaus. reliably for weeks at a time.
• Designed to extend plateaus • Maintains TPW cells for up to
• High-stability OEM controllers, six weeks
RS-232 included • Optional immersion freezer for
9210
• External cooling coils simple cell freezing
• Up to 496 mm (19.5 in) of
9210 Mini Triple Point immersion depth
of Water Maintenance
Apparatus 9117 Annealing Furnace
Simple supercool-and-shake Keeps SPRTs and PRTs perform-
realization and maintenance of ing at their highest levels.
the 5901B Mini TPW Cell. • Relieves mechanical strain
• Easy preprogrammed • Guards against contamination
realization • Anneals both SPRTs and
• Inexpensive fixed-point HTSPRTs
solution
9230 • Training complete in less than 7196B LN2 Comparison
an hour Calibrator
Lowest-cost calibration to
9230 Gallium Cell -196 °C.
Maintenance Apparatus • Simple to use
Realize and maintain the melting • Uncertainty less than 2 mK
point of the 5943 Gallium Cell.
• One week plateau duration
• No hassle automatic
realizations
• Used daily in our Primary Lab

9260 Mini Fixed-Point Cell


9260 Furnace
Inexpensive, easy-to-use fixed-
point maintenance apparatus.
• Realize and maintain In, Sn, Zn
and Al fixed-point cells
• Good introduction to fixed-
point calibration
• User friendly and inexpensive

7312

www.flukecal.com Temperature Calibration 19


1586A DAQ-STAQ Multiplexer 1620A

Thermometer readouts
1586A Super-DAQ Precision 1529 Chub-E4 Standards
Temperature Scanner and Thermometer
DAQ-STAQ Multiplexer Lab-quality accuracy on four
1594A/1595A channels for PRTs, thermistors and
Best-in-class temperature mea-
surement accuracy and up to thermocouples.
40 isolated input channels for • Four channels for PRTs, thermis-
measuring RTDs, thermocouples, tors, and thermocouples
thermistors, dc voltage, dc • Displays eight user-selected data
current, and resistance. fields from any channel
• PRTs: ± 0.005 °C; • Logs up to 8,000 readings with
5430 Thermocouples: ± 0.29 °C; date and time stamps
Thermistors: ± 0.002 °C
• Scan speed of up to 10 chan- 1502A/1504 Thermometer
nels per second Readouts
• Real-time color trending— Best performance thermometers in
chart up to four channels their price range.
simultaneously • Single-channel reference
• Control Fluke Calibration thermometers
1560 temperature sources such as • Two models to choose from—
dry-wells or Micro-Baths for reading PRTs or thermistors
automated calibration routines • Best price/performance package
1594A/1595A Super- 1523/1524 Reference
Thermometers Thermometers
Thermometry bridge accuracy Measure, graph and record three
combined with time-saving sensor types with one tool.
1529
features. • High accuracy: PRTs: ± 0.011 °C;
• Calibrate SPRTs, PRTs, RTDs Thermocouples: ± 0.24 °C;
and thermistors (0 Ω to 500 kΩ) Thermistors: ± 0.002 °C
• Accuracy as good as 0.06 ppm • A simple user interface to see
(0.000015 °C) trends quickly
• “Ratio Self-Calibration” verifies • Smart connectors to load probe
and calibrates resistance ratio information automatically
1502A/1504 accuracy
1551A Ex and 1552A Ex
5430 Standard AC/DC “Stik” Thermometer
Resistor
The best substitute for precision
Best performance available in an mercury-filled glass thermometers.
ac/dc resistor. • Accuracy of ± 0.05 °C
• Long-term stability better than (± 0.09 °F) over full range
2 ppm/year (< 1 ppm typical) • Intrinsically safe (ATEX and
• Traceable ac and dc calibra- IECEx compliant)
tions available • Two models to choose from
• National lab design proven for (-50 °C to 160 °C or -80 °C to
more than 25 years 300 °C)
1523/1524
1560 Black Stack 1620A Digital Thermometer-
Thermometer Readout Hygrometer
Accurate, expandable and con- The most accurate temperature and
figurable readout. humidity graphical data logger on
• Reads SPRTs, RTDs, thermis- the market.
tors, and thermocouples • Superior accuracy
• Any configuration you like up • Network enabled
to eight modules • Powerful logging and
1551A Ex and 1552A Ex • High-accuracy reference ther- analysis tools
mometer (to ± 0.0013 °C)
20 Temperature Calibration www.flukecal.com
5608/5609 5616

5626/5628 5615 5640

5624
Secondary standard Thermistor standards Fast response PRTs
PRTs 5640 Series Thermistor 5622 Fast Response PRTs
5608/5609 Secondary PRTs Standards Probes Designed for temperature
Very stable thermometer from High accuracy temperature measurements requiring fast
–200 °C to 670 °C. probes with excellent stability. response or short immersion over
• 5608: –200 °C to 500 °C • Accuracy to ± 0.001 °C a wide range.
(80 mm minimum immersion) • Affordable system accuracy to • Time constants as fast as
• 5609: –200 °C to 670 °C ± 0.004 °C or better 0.4 seconds 5649/5650
(100 mm minimum immersion) • NIST-traceable calibration • Available as DIN/IEC Class A
• Calibration not included, included from manufacturer PRTs or with NVLAP-accredited
NVLAP-accredited calibration calibration, lab code 200348-0
optional, lab code 200348-0 High temperature PRT • Small probe diameters ranging
from 0.5 mm to 3.2 mm
5624 Platinum Resistance
5615 Secondary PRT Thermometer Small diameter
Reference-grade platinum industrial PRTs
Precision PRT accuracy at ther- 5627A
sensing element. 5618B Small Diameter
mocouple temperatures.
• –200 °C to 420 °C
• Temperature range of 0 °C to Industrial RTD
• ± 0.012 °C accuracy at 0 °C
1000 °C Secondary level performance
• Drift of ± 0.007 °C after 100
• Accuracy of ± 0.05 °C to with full ITS-90 calibration.
hours at max temperature
962 °C (includes short-term • Small diameter sheath, 3.2 mm
stability and calibration (0.125 in)
5626/5628 Secondary
uncertainty) • Excellent stability
SPRT, PRT, Temperature
• Long-term drift of 0.01 °C at • Includes ITS-90 coefficients
Sensors 0 °C after 100 hours at 1000 °C
5622
High-temperature secondary Full immersion PRTs
standards. Thermocouple 5606 Full Immersion PRT
• -200 °C to 661 °C standards
• Meets all ITS-90 requirements PRTs for laboratory freezers,
for resistance ratios 5649/5650 Type R and autoclaves, and furnaces.
• Rtp drift < 20 mK after 500 Type S Thermocouple • Transition junction designed
hours at 661°C Standards to withstand full temperature
Eight models to fit any type R or range of probe 5618B
Secondary reference S thermocouple applications. • 5606: -200 °C to 160 °C
PRTs • 0 °C to 1450 °C • Calibration accuracy of
• Two sizes available, each with ± 0.05 °C
5616 Secondary Reference
or without reference junction Secondary thermistor
PRT
• Optional fixed-point calibra- probes
• –200 °C to 420 °C tion, uncalibrated accuracy is
• Excellent stability: ± 0.007 °C the greater of ± 0.6 °C or 5610/5611/5611T/5665
• Calibrated accuracy ± 0.011 °C ± 0.1 % of reading Secondary Reference 5606
at 0 °C Thermistor Probes
Precision industrial PRTs Lab-grade thermistors probes for
accurate work across a narrow
5627A Precision Industrial
temperature range.
PRTs
• Short-term accuracy to
Durable PRTs with temperature ± 0.01 °C; one-year drift
range to 420 °C and accuracy to < ± 0.01 °C 5610/5611/
0.025 °C. • Accredited NVLAP calibration 5611T/5665
• Vibration and shock resistant optional
• NVLAP-accredited calibration • Flexible Teflon and silicone
included, lab code 200706-0 coated fast-response models

www.flukecal.com Temperature Calibration 21


7008/7040/7037/7012/7011 7080

6330/7320/7340/7380
Compact Standard
calibration baths calibration baths
6330/7320/7340/7380 6020/6022/6024 High
Compact Temperature Temperature Calibration Oil
Calibration Baths Baths
Compact baths with the stabil- Stable, uniform heat sources for
ity and uniformity required for calibrations up to 300 °C.
thermometer calibration. • Stability as good as 0.001°C
• Stability and uniformity each • Large-capacity tanks for higher
better than ± 0.008 °C productivity
• Metrology-level performance in • Built-in cooling coils for
lab-friendly sizes external cooling sources
• Convenient use on benchtops
or on matching carts 6050H Extremely High
6331/7321/7341/7381 Temperature Calibration
6331/7321/7341/7381 Salt Bath
Deep-Well Compact Baths Designed for high-temperature
Ample immersion depth and calibration—up to 550 °C.
great stability, in a high value • Eliminates messy sand baths
compact bath. • Electronically adjustable
• 457 mm (18 in) of depth with temperature cutouts
just 15.9 liters (4.2 gal) of fluid • Stability of ± 0.008 °C at
• Perfect for liquid-in-glass ther- 550 °C
mometers with optional LIG kit
• Fast, quiet, compact (yet deep), 7008/7040/ 7037/
and economical 7012/7011 Cold
Temperature Calibration
7312 7312 Triple Point of Water Baths
Maintenance Bath
High stability means low calibra-
Keep your cells up and running tion uncertainties—no other bath
reliably for weeks at a time. performs this well.
• Maintains TPW cells for up to • Stability to ± 0.0007 °C
six weeks • Best digital temperature con-
• Optional immersion freezer for troller available
simple cell freezing • “Super Tweak” function pro-
• Independent cutout circuit vides set-point resolution to
protects cells from breaking 0.00003 °C

7080 Really Cold


6020/6022/6024 Temperature Calibration
Baths
Cool to –40, –60, or –80 °C with-
out external coolants.
• Self-contained refrigeration—
no LN2 or chiller required
• Temperatures as low as –80 °C
in real metrology baths
• Stability of ± 0.0025 °C at
–80 °C

6050H

22 Temperature Calibration www.flukecal.com


2100 and 2200

6054/6055/7007
7900

Bath controllers 9170/9171/9172/9173

2100 and 2200 Benchtop


Temperature Controllers Metrology Wells
Most stable temperature control- 9170/9171/9172/9173
lers available. Metrology Well Calibrators
• Resolution as high as
0.00018 °C Accurate enough for lab use yet
• RS-232 interface included for rugged and portable.
automating applications • Best-performing industrial heat
7009/7108/7015 sources (accuracy, stability,
7900 Controller for uniformity) in the world
Special Rosemount-Designed Baths • –45 °C to 700 °C
• Immersion depth to 203 mm
application baths All the features of the Fluke Cali-
bration 2100 Controller.
(8 in)
• Optional ITS-90 reference input
6054/6055/7007 • Installs easily reads PRTs to ± 0.006 °C
Deep-Well Baths • Two independent over-
Extra-deep wells for thermometry temperature cutout circuits
work requiring extra tank depth
and ultimate stability.
• Constant liquid levels through
concentric-tube design
• Special design for sighting LIG
thermometers
• Depth up to 60 cm (24 in)

7009/7108/7015
Resistor Baths
Three size options for any quan-
tity of resistors.
• Stability to ± 0.0007 °C
• Independent high- and low-
temperature cutout circuit

www.flukecal.com Temperature Calibration 23


9190A 9100S/9102S 9009

Field Metrology Field dry-well


Wells calibrators
9190A Ultra-Cool Field 9103/9140 Field
Metrology Well Dry-Well Calibrators
Ultra-cool dry-block calibrator Great performance in portable
with best-in-class stability. instruments.
• Wide temperature range from • Lightweight and very portable
–95 °C to 140 °C • Accuracy to ± 0.25 °C
9142/9143/9144 • Best-in-class stability: • RS-232 and Interface-it
± 0.015 °C full range software included
• Accuracy using built-in refer-
ence thermometer readout:
± 0.05 °C full range
Micro-Baths
• Display accuracy: ± 0.2 °C full 6102/7102/7103
range Micro-Bath Thermometer
9142/9143/9144 Field Calibrators
Metrology Wells Portable and extremely stable.
• Small portable calibration
Small dry wells for big field
baths
applications.
• Calibrates sensors of any size
• Lightweight, portable, and fast
9011 or shape
• Cool to –25 °C in 15 minutes
• Stability to ± 0.015 °C
and heat to 660 °C in 15
minutes
• Built-in two-channel readout Handheld
for PRT, RTD, thermocouple,
4-20 mA current
calibrators
9100S/9102S Handheld
Dual-block Dry-Wells
Small, light, and portable
dry-well dry-wells.
9011 High-Accuracy • Ranges from –10 °C to 375 °C
Dual-Well Calibrator • Accuracy to ± 0.25 °C, stability
9103/9140 of ± 0.05 °C at 0 °C
Widest temperature range avail-
able in a single dry-well. 9009 Industrial Dual-Block
• Combined range from –30 °C to
Thermometer Calibrator
670 °C, one unit—two blocks
• Two independent temperature Double your productivity or cut
controllers (hot and cold side) your calibration time in half.
• Stability to ± 0.02 °C • Temperatures from –15 °C to
350 °C in one unit
• Two wells in each block for
simultaneous comparison
calibrations
• Rugged, lightweight, water-
6102/7102/7103 resistant enclosure

24 Temperature Calibration www.flukecal.com


4180/81 9132 and 9133

Infrared Surface probe


calibrators calibrator
4180/81 Precision Infrared 3125 Surface Probe
Calibrators Calibrator
Accredited performance for point- Milled aluminum for a smooth
and-shoot calibrations. and true calibration work
• Calibrated radiometrically for area with maximum thermal
meaningful, consistent results conductivity. 9150
• Accredited calibration included • Calibrates surface sensors up
• Accurate, reliable performance to 400 °C
from –15 °C to 500 °C • Uses Fluke Calibration 2200
Controller for excellent accu-
9132 and 9133 Portable racy and stability
Infrared Calibrators • NIST-traceable calibration
Precision when you need it for included
infrared temperature calibration.
• Certify IR pyrometers from Thermocouple
–30 °C to 500 °C (–22 °F to
932 °F) furnaces 9101

• Large 57 mm (2.25 in) black- 9150 Thermocouple


body target
• RTD reference well for contact
Furnace
temperature measurement Convenient, portable thermo-
couple furnace.
• 150 °C to 1200 °C
Zero-point • Stability of ± 0.5 °C over full
dry-well range
• NIST-traceable calibration 3125
9101 Series Metrology
included
Well Calibrators • RS-232 port standard
Ice-point reference without
the ice. 9118A Thermocouple
• ± 0.005 °C stability in a Calibration Furnace
portable ice-point reference
• Easy re-calibration for long- High performance furnace for
term reliability thermocouple calibrations to
• Ready light frees user’s time 1200 °C. The Fluke Calibration
and attention 9118A Thermocouple Calibration
Furnace is a horizontal, open-
ended tube furnace with 9118A
a temperature range of 300 °C
to 1200 °C.
• Wide temperature range
• Calibrates many thermocouple
types
• Best-in-class temperature
stability and uniformity
• Automated setpoint control

www.flukecal.com Temperature Calibration 25


Pressure calibration
Pressure calibration is the comparison of the The test fluid inside a pressure calibration
output of a device used to measure pressure with system may be liquid or gas depending on the
that of another pressure measurement device, application. In general, gas (usually compressed
or pressure measurement standard. This usually nitrogen or air) is used for cleanliness and
involves plumbing the unit under test (UUT) to precision at lower pressures, and liquids (usually
the standard device and generating a common oil or water) are often used for safety, leak
pressure in the measurement circuit. The outputs integrity, and ease of pressure generation at
of the devices are compared at one or more higher pressures above 7 MPa to 21 MPa (1000 psi
pressures, typically from the lowest to highest to 3000 psi). There is a great deal of overlap in
readings of the UUT’s full scale range, or the the actual ranges for which liquid or gas may be
range over which it is normally used.  used practically, as reflected in the range of Fluke
The comparison process can be performed in Calibration instruments that are specialized for
a chain from the highest level of fundamental each type of test fluid.
pressure realization down to everyday pressure
measurement devices, such as analog gauges,
transducers and transmitters, to ensure that
pressure measurements are accurate and comply
with accepted or mandated standards.

26 Pressure Calibration www.flukecal.com


Product highlights

6270A Modular Pressure 2700G Series Reference 3130 Portable Pressure


Controller/Calibrator Pressure Gauges Calibrator
Calibrate a wide range of Best-in-class measurement The 3130 packs everything
pressure gauges and sensors performance in a rugged, easy- you need for accurate
with a single instrument to-use, economical package. calibration of pneumatic
• Modular configuration makes Improved measurement accuracy field instrumentation into a
this a versatile and expandable allows the 2700G to be used for rugged case suitable for harsh
solution a wide variety of applications. industrial environments.
• Easy to operate and maintain It is ideal for calibrating pres- • Measure and generate pres-
• Wide measurement range— sure measurement devices such sures from vacuum to 2 MPa
vacuum to 3000 psi (20 MPa) as pressure gauges, transmit- (300 psi, 20 bar)
• Two levels of accuracy—0.02% ters, transducers, and switches. • Internal pump can generate
FS or 0.01% reading—let you In addition, it can be used as vacuum to -80 kPa (-12 psi,
balance performance and a check standard or to provide -0.8 bar) or pressure to 2 MPa
budget process measurements with data (300 psi, 20 bar)
• High speed, stable pressure logging. • Supply pressure connection
control • Precision pressure measure- allowing the use of exter-
• Localized graphical user inter- ment from 100 kPa (15 psi) to nal gas supply up to 2 MPa
face in choice of ten languages 70 MPa (10,000 psi) (300 psi, 20 bar)
• Can be fully automated • Accuracy to 0.02 % of full scale • Includes variable volume for
with COMPASS® for Pressure • Easy-to-use, rugged construc- fine adjustment of pressures
software tion for reliable performance • Pressure measurement accu-
• Optional contamination pre- • Combine with the 700PTPK racy of 0.025 % reading
vention system keeps valves or 700HTPK pump kits for a ± 0.01 % FS
clean and free from debris complete portable pressure • Electrical measurement and
testing solution for up to 4 MPa 24 volt supply for close looped
(600 psi) with the PTP-1 pneu- calibrations
matic pump and up to 70 MPa • Measure or generate 4 mA to
(10,000 psi) with the HTP-2 20 mA
hydraulic pump • Measure 0 to 30 V dc
• Combine with the P5510, • Powered by internal,
P5513, P5514, or P5515 rechargeable, high capacity
Pressure Comparators for a NiMH battery or universal ac
complete bench top pressure mains adapter
calibration solution • Compatible with Fluke 700P
• Test port is 1/4 NPT Male. 1/4 Pressure Modules
BSP and M20 X 1.5 adapters
are included standard
• USB communications cable
and universal power supply
included standard

www.flukecal.com Pressure Calibration 27


Selection guide
Gas Pressure Calibrators
This selection guide presents only some of the Fluke Calibration gas pressure calibration
line. Other higher accuracy solutions are available for all pressure ranges.

Manual *Requires vacuum pump


Deadweight testers
=Optional
0.0015 % FS
0.015 % reading uncertainty

P3032
P3023
P3022

P3025

P3031
P3012

P3013

P3015
P3014
P3011
Workload
Gauges/sensors
Gage
Bidirectional*
Pressure range
Vacuum
90 % vacuum
Positive gage pressure
5 inH₂O (1.5 kPa)
12 inH₂O (3 kPa)
1.5 psi (10.3 kPa)
2 psi (13.8 kPa)
2.2 psi (15 kPa)
3 psi (20.7 kPa)
5 psi (34.4 kPa)
10 psi (68.9 kPa)
15 psi (103.4 kPa)
20 psi (137.9 kPa)
30 psi (200 kPa)
40 psi (275.8 kPa)
100 psi (.7 MPa)
150 psi (1 MPa)
200 psi (1.4 MPa)
300 psi (2 MPa)
500 psi (3.4 MPa)
600 psi (4 MPa)
1000 psi (7 MPa)
2000 psi (14 MPa)
Accessories
Hand pump
Fine Inc. Weights

28 Pressure Calibration www.flukecal.com


Selection guide
Hydraulic Pressure Calibrators
This selection guide presents only some of the Fluke Calibration hydraulic pressure
calibration line. Other higher accuracy solutions are available for all pressure ranges.

Manual Semi Automated


Deadweight Testers EDWT Electronic Deadweight Tester
6531 6532
P3111

P3112

P3113

P3114

P3115

P3116

P3123

P3124

P3125

P3830

P3840

P3860

P3211

P3213

P3214

P3223

P3224

140M

200M
140M

200M

70M
14M

20M

40M

70M
7M
Fluid type
Oil
Water
Workload
Gauges/sensors*
Gage
Pressure range
10 psi (68.9 kPa)
15 psi (103.4 kPa)
20 psi (137.9 kPa)
30 psi (200 kPa)
40 psi (275.8 kPa)
100 psi (.7 MPa)
150 psi (1 MPa)
200 psi (1.4 MPa)
300 psi (2 MPa)
500 psi (3.4 MPa)
600 psi (4 MPa)
1000 psi (7 MPa)
2000 psi (14 MPa)
3000 psi (20 MPa)
5000 psi (35 MPa)
6000 psi (40 MPa)
10000 psi (70 MPa)
16000 psi (110 Mpa)
20000 psi (140 MPa)
30000 psi (200 MPa)
40000 psi
(275.8 MPa)
60000 psi (400 MPa)

0.015 % reading uncertainty


0.002 % full scale uncertainty
0.0015 % full scale uncertainty
0.0075 psi (0.05 kPa) uncertainty
0.0002 % span uncertainty

www.flukecal.com Pressure Calibration 29


6270A 7250LP 7250/7250i

Gas pressure 7252/7252i Dual Output


Gas Pressure Controllers
controllers/calibrators A unique and flexible approach to per-
forming automated calibrations over a
6270A Modular Pressure wide pressure range.
Controller/Calibrator • Two independent pressure
Calibrate a wide range of pressure gauges measurement and control modules
and sensors with a single instrument • Two performance models available,
• Modular configuration makes this a 7252i and 7252
7250xi versatile and expandable solution • Fast control: <15 seconds with zero
• Wide measurement range—vacuum overshoot
to 3000 psi (20 MPa) • Full scale ranges from 0 to 2.5 kPa
• Two levels of accuracy—0.02% FS and to 21 MPa (0 to 0.36 psi and to
or 0.01% reading—let you balance 3000 psi)
performance and budget
• Can be fully automated with COMPASS® PPC4 Gas Pressure Controller/
for Pressure software Calibrator
• Optional contamination prevention Wide rangeability and flexibility in a
system keeps valves clean and free single controller. Ranges and accuracy
from debris classes can be selected to best suit the
7252/7252i application.
7250LP Low Pressure Controller/ • Up to two internal Quartz Reference
Calibrator Pressure Transducers (Q-RPTs) from
Specialized measurement and control for absolute (vacuum) to 14 MPa (2000 psi)
very low draft pressure range. • Full-scale standard class Q-RPTs
• Precision: 0.005 % of reading provide 0.015 % full scale of selected
• Control stability: 0.004 % of each range range measurement uncertainty
• Resolution to 0.0001 in H 2O • Standard class Q-RPTs provide 0.01 %
• Full scale ranges from 0 to 10 in H 2O reading measurement uncertainty
(2.5 kPa) to 0 to 100 in H 2O (25 kPa) • Premium class Q-RPTs provide 0.008 %
reading measurement uncertainty
PPC4 7250/7250i Gas Pressure • 4 ppm control precision as low as 1 kPa
Controllers/Calibrators (0.15 psia) with large turndown
Combining advanced precision, stability, • Can use RPM4 reference pressure
speed and affordability. monitors as integrated remote pressure
• Pressure ranges from 0 to 40 kPa and references for additional Q-RPT ranges
to 21 MPa (0 to 5 psi and to 3000 psi,
0 to 400 mbar and to 210 bar) PPC4E Pressure Controller/
• Model 7250i provides precision of Calibrator*
0.005 % of reading Very wide rangeability and reliability
• Model 7250 provides 0.003 % of full at a great value, for everyday pressure
scale precision calibration.
PPC4E • Stability: 0.0075 % of reading per year • Models available with 10:1 or 100:1
• Time to setpoint: 15 seconds with no accurate measure and control range
*6241 and 6242 overshoot turndown for maximum workload
PPC4E gas pressure coverage
controller kits fea- 7250xi High Performance Gas
• Absolute, gauge and bidirectional gauge
ture PPC4E models Pressure Controllers/Calibrators modes included in most models
and accessories to
form a complete Unmatched precision and speed. • Gauge calibration measurement uncer-
system that covers • Pressure ranges from 0 to 40 kPa and tainty ± 0.02 % of selected range, with
a very wide to 17 MPa (0 to 5 psi and to 2500 psi,
workload.
range options available from ± 1 kPa
0 to 400 mbar and to 170 bar) (± 0.15 psi) to 14 MPa (2000 psi)
• Advanced precision of 0.005 % of read- • Absolute range of 1 kPa (0.15 psi) to
ing from 5 % to 100 % of full scale 14 MPa (2000 psi)
• Stability: 0.0075 % of reading per year
• Time to setpoint: 15 seconds with no
overshoot

30 Pressure Calibration www.flukecal.com


7350 PPCH-G

High pressure Reference


controllers/ pressure
calibrators indicators
7350 High Pressure Gas RPM4 Reference Pressure
Controller/Calibrator Monitor
Safe, easy-to-use, and effec- Premium measurement perfor-
tive high pressure test and mance in a compact and rugged 7615
calibration. instrument.
• Ranges to 70 MPa • One or two independent quartz
(10 k psi, 700 bar) reference pressure transducer
• Measurement precision to modules (Q-RPTs) with indi-
0.01 % of range vidual self-defense systems
• Control stability 0.007 % FS (SDS™) to prevent over-pressure
• Infinite Ranging and
PPCH-G High Pressure Gas AutoRange™
Controller/Calibrator • Differential measurement mode
Wide rangeability and flexibility (channel 1- channel 2)
with precise high pressure gas • Dedicated version available PPCH
control. for air data ranges units and
• Ranges to 100 MPa (15 k psi) features, RPM4-AD
• One or two internal Q-RPTs • Can be used as integrated
with large range turndown external reference pressure
• Can use RPM4 reference transducer for PPC pressure
pressure monitors as integrated controller/calibrators
remote pressure references for
additional Q-RPT ranges 7050 Series Digital Pressure
Indicators
7615 Hydraulic Pressure Unmatched precision with long
Controller/Calibrator term stability. RPM4
Unique, high speed approach to • Pressure ranges from
high pressure calibration and 0 to 10 in H 2O and 0 to
testing. 1,500 psi (0 to 25 mbar and
• Ranges to 280 MPa (40 k psi) 0 to 100 bar)
• Measurement precision to • Model 7050i provides precision
0.01 % of range of 0.005 % of reading
• Available in a variety of fluids, • Model 7050 provides 0.003 %
including water of full scale precision
• High speed pressure control • Active matrix color screen with
enhanced navigation menus
• Model 7050LP provides 7050
PPCH Hydraulic Pressure
Controller/Calibrator precision of 0.005 % reading
for very low draft pressure
Wide rangeability and flexibil-
ranges
ity with precise high pressure
hydraulic control.
• Ranges to 200 MPa (30 k psi)
• One or two internal Q-RPTs
with large range turndown
• High precision control over
wide range
• Can use RPM4 reference
pressure monitors as integrated
remote pressure references for
additional Q-RPT ranges

www.flukecal.com Pressure Calibration 31


PG7601

PG7202 PG7000-AMH

PG7102

PG7302 2465A 2470

Piston gauges PG7202 High Pressure Gas 2465A Absolute Gas Piston
Piston Gauge Gauge
PG7601 Absolute Gas Piston Gas piston gauge with oil-lubri- Gas piston gauge capable of very
Gauge cated piston-cylinder for operation low pressures, for defining gauge
Gas piston gauge with vacuum in high pressure gas or oil. and absolute pressures.
reference for defining absolute • Gas pressures from 100 kPa to • Gas pressure from 1.5 kPa to
pressures. 110 MPa (15 to 16,000 psig), 7 MPa (0.2 psi to 1000 psi)
• Gas pressure from 5 kPa to oil pressures from 100 kPa to gauge or absolute pressure
7 MPa (0.7 psi to 1000 psi) 200 MPa (15 to 30,000 psig) • Lightweight, compact system
gauge or absolute pressure • Gas operated, liquid lubricated with small masses for reduced
• Onboard measurement of test for robust operation and low bench space, transportability
conditions, and real-time piston sink rates and ergonomic mass handling
calculation and display of test • Onboard measurement of test • Compatible with WinPrompt
pressure conditions, and real-time and COMPASS software
• Compatible with PPC4 pres- calculation and display of test
sure controller and AMH-38 pressure 2470 Gas Piston Gauge
Automated Mass Handler • Compatible with PPCH-G pres- Gas piston gauge capable of very
sure controller and AMH-100 low to high gauge pressures.
PG7102 Gas Piston Gauge Automated Mass Handler • Pressures ranges from
Gas piston gauge with 55 kg 1.5 kPa to 20 MPa (0.2 psi
mass set for extended range mea-
PG7302 Piston Gauge to 3000 psig)
surement of gauge pressures. Oil piston gauge for measurement • Lightweight, compact system
• Gas pressures from 100 kPa of high gauge pressures. with small masses for reduced
to 11 MPa (15 to 1,600 psig) • Oil pressures from 100 kPa to bench space, transportability
• Onboard measurement of test 500 MPa (15 psi to 75,000 psig) and ergonomic mass handling
conditions, and real-time • Onboard measurement of test • Compatible with WinPrompt
calculation and display of test conditions, and real-time and COMPASS software
pressure calculation and display of test
• Compatible with PPC4 pres- pressure
sure controller and AMH-100 • Compatible with PPCH pres-
Automated Mass Handler sure controller and AMH-100
Automated Mass Handler

PG7000-AMH Automated
Mass Handler
Automated Mass Handler for
PG7000 Piston Gauges.
• Add to PG7000 Series piston
gauge to fully automate
pressure testing in gauge or
absolute mode
• Designed and tested to provide
years of reliable, maintenance
free operation
• Reduce wear and possible
mass value changes caused by
manual mass handling

32 Pressure Calibration www.flukecal.com


PG9607/ PG9602

GPC1
Manual pressure
generation
and control
3990 Gas Pressure Control
Pack
Precise, manual absolute and
gauge pressure control for gas
MPG2
piston gauges and indicators.
2482 • Models from vacuum to 7 MPa
and 20 MPa (1000 psi and
3000 psi)
• Self-contained for intuitive,
easy use

GPC1 High Gas Pressure


Controller
Precise, assisted manual control
for high pressure gas piston
gauges and indicators.
OPG1 • Models to 70 MPa and 110 MPa
(10 k psi and 16 k psi)
FPG8601
• Precise control to full pressure
2482 Differential Piston with simple, ergonomic push-
Gauge button operation
High precision differential pres-
sure measurement at elevated MPG2 Hydraulic Pressure
line pressures. Generator/Controller
3990
• Measures differential pressures Precise, manual control for
using a gas or oil medium hydraulic piston gauges and
• Differential pressure to 210 kPa indicators.
Specialty piston (30 psi, 2100 mbar) at static • Models to 100 MPa and
gauges line pressure range to 20 MPa 200 MPa (15 k psi and 30 k psi)
(2900 psi, 200 bar) • Self-contained for intuitive and
PG9607 Gas Piston Gauge • Quickly and easily set differen- easy generation and
Fully automated primary pressure tial pressures with lightweight precise control to full pressure
reference for absolute and gauge masses
pressures to 500 kPa. • Fully automated pressure con- OPG1 Hydraulic Pressure
• Gauge and absolute pressures trol and pressure determination Generator/Controller
from 11 kPa to 500 kPa with a using WinPrompt software Precise, assisted manual control
single piston-cylinder for hydraulic piston gauges and
FPG8601 Force-Balanced indicators.
• Large diameter 50 mm piston-
Piston Gauge • Pressure to 200 MPa (30 k psi)
cylinder with improved geom-
etry allows direct traceability Gas pressure calibration system • Precise generation and control
to dimensional measurements for very low gauge, differential to full pressure with simple,
with very low uncertainties and absolute pressures. ergonomic push-button
• Gas pressure from 0 to 15 kPa operation
PG9602 Gas Piston Gauge (113 Torr) in gauge, differential
Fully automated primary pressure and absolute modes
reference for absolute and gauge • Measurement uncertainty to
pressures to 11 MPa. ± (5 mPa + 30 ppm of reading)
• Gauge and absolute pressures in gauge and absolute differen-
from 10 kPa to 11 MPa tial mode, ± (8 mPa + 30 ppm
• Up to 100 kg mass load under of reading) in absolute mode
vacuum bell jar for large • Fully automated, including test
turndown and overlap of execution, pressure control and
piston-cylinder ranges reference and device under test
data collection
www.flukecal.com Pressure Calibration 33
Industrial
P3000 deadweight testers
P3000 Pneumatic
Deadweight Tester P5514
High performance gas dead- with 2700G
weight testers, with unique
suspended piston design for
P3100 vacuum calibration. Pressure
• 0.015 % of reading accuracy comparators
standard (0.008 % optional)
• 3 to 500 psi (0.2 to 35 bar) P5510 Pneumatic Pressure
pressure Comparator*
• Optional low range 0.03 to Precise, cost effective solution
1 bar vacuum (1 to 30 inHg) for checking pressure measuring
• Integrated vacuum and pres- instruments to 300 psi (20 bar).
P3200
sure pump available to 2 MPa • Dual pressure/vacuum
(300 psi) capability
• Pressure to 20 MPa (300 psi,
P3100 Hydraulic 20 bar)
Deadweight Tester • Vacuum from 0 to 80 kPa
Highly accurate oil deadweight (0 to 24 inHg, 800 mbar)
tester, with quick and easy- • Built-in pressure and vacuum
to-use single and dual piston generation
deadweight models.
• Pressure ranges to 140 MPa P5513 Pneumatic Pressure
(20 k psi, 1400 bar) Comparator*
P3800 • 0.015 % of reading accuracy Precise, cost effective solution
standard (0.008 % optional) for checking pressure measur-
• Built-in pressure generation ing instruments to 3,000 psi
and adjustment (7210 bar).
• Single or dual piston formats • Pressure range 0 to 210 MPa
(3 k psi, 210 bar)
P3200 Hydraulic • High pressure pneumatic
Deadweight Tester operation
P5510 Hydraulic deadweight tester spe- • Screw press for fine pressure
cially designed to use water as a adjustments
test medium. • High quality needle valves for
• Pressure ranges to 70 MPa fine control
(10 k psi, 700 bar)
• 0.015 % of reading accuracy P5514 and P5515 Series
standard (0.008 % optional) Hydraulic Pressure
• Built-in pressure generation Comparators*
P5513 and adjustment is standard Quick and easy solutions for
• Single or dual piston formats checking pressure measur-
• Water media ing instruments to 10,000 psi
(700 bar).
P3800 Hydraulic • Compatible with a wide range
Deadweight Tester of fluids
High performance and simplicity • P5514 Test Pump generates
for very high pressure hydraulic pressures to 70 MPa (10 k psi,
calibration. 700 bar)
P5514 • Pressure ranges to 400 MPa • P5515 Test Pump generates
(60 k psi, 4000 bar) pressures to 140 MPa (20 k psi,
• 0.02 % of reading accuracy 1400 bar)
standard (0.015 % optional) • P5515 has a built-in hand
• Includes hand pump and pump for system priming and
intensifier for generating and large volume applications
adjusting high pressures
P5515

* Can be used with the 2700G Reference Pressure Gauge to provide a complete calibration solution

34 Pressure Calibration www.flukecal.com


Pressure E-DWT-H Electronic
calibrators Deadweight Tester
A digital alternative to the tradi-
4322 Automated Pressure tional deadweight tester.
Calibrator • Set and measure pressure
• Rugged, lightweight, compact precisely without limitation of
components for use on the mass loading resolution
bench or in-situ • Pressure measurement is
• Precise automated pressure insensitive to local gravity and
control from vacuum to 70 MPa orientation
gauge (10,000 psi) • One year uncertainty of
± 0.02 % of reading 4322
• Greater of 0.1 % of reading or
25 Pa (0.004 psi, 0.1 in H2O) • Run onboard test routines
accuracy across the entire and store calibration data for
pressure range review and export to a PC
• Onboard pressure/vacuum
generation from 3.5 kPa (0.5 2700G Series Reference
psi) absolute to 2 MPa (300 psi) Pressure Gauges
Best-in-class measurement
3130 Portable Pressure performance in a rugged, easy-
Calibrator to-use, economical package.
Everything you need to generate, • Precision pressure measure-
control and measure pressure, ment from 100 kPa (15 psi) to 3130
as well as read the output of the 70 MPa (10,000 psi)
device under test (DUT). • Accuracy to 0.02 % of full scale
• Measure and generate pres- • Easy-to-use, rugged construc-
sures from vacuum to 2 MPa tion for reliable performance
(300 psi, 20 bar) • Combine with the 700PTPK
• Internal pump can generate or 700HTPK pump kits for a
vacuum to -80 kPa (-12 psi, complete portable pressure
-0.8 bar) or pressure to 2 MPa testing solution for up to 4 MPa
(300 psi, 20 bar) (600 psi) with the PTP-1 pneu-
• Supply pressure connection matic pump and up to 70 MPa
allowing the use of exter- (10,000 psi) with the HTP-2 E-DWT-H
nal gas supply up to 2 MPa hydraulic pump
(300 psi, 20 bar) • Combine with the P5510,
• Includes variable volume for P5513, P5514, or P5515
fine adjustment of pressures Pressure Comparators for a
• Pressure measurement complete bench top pressure
accuracy of 0.025 % reading calibration solution
± 0.01 % FS • Test port is 1/4 NPT Male. 1/4
• Electrical measurement and BSP and M20 X 1.5 adapters
24 volt supply for close looped are included standard
calibrations • USB communications cable
• Measure or generate 4 mA to and universal power supply
20 mA included standard
• Measure 0 to 30 V dc 2700G
• Powered by internal, recharge-
able, high capacity NiMH
battery or universal ac mains
adapter
• Compatible with Fluke 700P
Pressure Modules

www.flukecal.com Pressure Calibration 35


Air data calibration Pressure
calibration systems
7750i Air Data Calibrator
Air data test set with unequalled 7250sys Multi-Range
precision and long term stabil- Pressure Calibration System
ity and superior pressure control Turn-key automated gas pressure
technology. calibration system.
7750i
• High accuracy, RVSM compliant • Gas pressure measurement and
• Accuracy to ± 2 feet, control from low absolute to
0.02 knots 17 MPa (2500 psi)
• True differential sensor for • Fully integrated multi-range
airspeed (Qc) pressure test and calibration
systems with a single interface
RPM4-AD Reference and single test port
Pressure Monitor • Select either an 8 range or the
RPM4-AD Specialized pressure indicator 12 range system for maximum
for the absolute and differen- performance and coverage
tial pressure ranges in air data
instruments. Custom Pressure Calibration
• Fixed wing and rotary wing Systems
range versions Engineered custom systems inte-
• True Pt, Ps, Qc operation grate standard Fluke Calibration
2468A products into a complete system
2468A Pitot/Static Primary based on the user’s specific
Standard requirements. These are often
Gas piston gauge specialized for multi-range systems that include
air data absolute and differential pressure generation and supply
pressure ranges. accessories, data acquisition
• Pressure range: 0.4 inHg to hardware and software and/or
103 inHg test instrument connection mani-
• Optional range: 3.4 inHg to folds. Custom systems include but
400 inHg are not limited to turn-key pres-
• Accuracy to ± 0.5 feet, sure calibration rack systems,
0.003 knots portable calibration carts and
• Extended mass set covers automated pressure calibration
entire air data range without bench systems.
the need to change pistons
• Compatible with WinPrompt
and COMPASS software

7250sys

36 Pressure Calibration www.flukecal.com


Gas flow calibration
What is gas flow calibration? Mass flow vs. volume flow
Gas flow calibration refers to the calibration of a A frequent topic of discussion and confusion sur-
flow sensing device such as a flow meter or flow rounding gas flow measurement is that of mass
controller by comparing its measurement against a flow versus volume flow. Flow meters and flow
flow measurement reference. Typically, the device, units used for flow measurements are used to
or unit under test (UUT), is pneumatically con- measure and express either the amount of volume
nected in series with the flow reference so they of gas or the amount of mass (number of moles or
measure the same gas flow; then the indications of molecules) passing through the device. When per-
the two devices are compared. forming a gas flow calibration, it is nearly always
molbloc™/molbox™ system components beneficial to use a mass flow reference measure-
Fluke Calibration’s molbloc/molbox gas flow cali- ment, because the mass flow rate stays constant
bration system consists of molbloc flow elements throughout a flow system in steady state. Since
that connect to a flow terminal (either molbox1+ or gas is compressible, the volume flow rate varies at
molbox RFM) so the terminal can use pressure and different locations in a flow system due to changes
temperature measurements from around the flow in density caused by changing temperature and
element, combined with gas properties and prior pressure. Fluke Calibration molblocs are mass flow
molbloc calibration data, to determine and display standards, which allow reliable comparisons to
the gas flow rate. other flow devices. The molbox terminal is also
able to calculate and express the flow rate in terms
of volume flow at another point in the system to
allow testing of volume-based devices.

www.flukecal.com Gas Flow Calibration 37


molstic-L
MFC-CB™
molbox1+

molstic-S
MFC Switchbox
molboc-L
molbloc-S Sonic Nozzle
Flow Element
Sonic nozzle based molblocs for
gas flow up to 5,000 slm.
• Covers ranges up to 5,000 slm
molbloc-S in N2 and air
• Multiple gases supported
• Useable with molbox1+, or
existing molbox1 and molbox
RFM mass flow terminals and
COMPASS software GFS™
• Proven critical flow ven-
molbox RFM turi (sonic) nozzle operating Gas Flow Automation
principle traceable to primary Accessories
Gas flow standards gravimetric flow measurements MFC-CB™ Control Box
molbox1+ Flow Terminal molbox RFM Reference Flow
Stand-alone unit for setting/
0.125 % of reading—lowest uncer- reading analog mass flow
Monitor controllers (MFCs) and mass
tainty for gas flow calibration.
Compact terminal for making mass flow meters (MFMs).
• Allows coverage of flow range
flow measurements using molbloc-L • Set and read 0 to 5 V or 4 to
from less than 1 sccm to over
and molbloc-S flow elements. 20 mA on two (2) channels
5000 slm with a single user
• Economical alternative to • Complete front panel local
interface and transportable
molbox1+ terminal control and remote operation
system
• ± 0.5 % of reading uncertainty via RS-232 and IEEE-488
• Real-time flow measurements
• Covers the flow range of 1 sccm interfaces
makes adjusting analog flow
to 100 slm with molbloc-L, and MFC Switchbox™
devices fast and easy
up to 5000 slm with molbloc-S Supplies power and switches
• Perform fully-automated flow
• 5141/5142/5144 kits feature between up to five MFCs or
calibrations using molbox ter-
molbox RFM, molbloc-L and MFMs on one molbox1+ or
minal with COMPASS for Flow
other hardware for a complete MFC-CB channel.
software
calibration system • Duplicates MFC channel
• Updated design
• No moving parts that cause without switching cables
molboc-L Laminar Flow pressure/flow fluctuations or
threaten reliability
Element Primary gas
Laminar flow elements for flow molstic Mounting Systems flow standard
from 1 sccm to 100 slm.
• Traceable to primary gravimet- Used to conveniently mount and GFS Dynamic Gravimetric
ric mass flow measurements protect molbloc elements, connect Mass Flow Standard
• Multiple gases supported to units under test and provide
True Primary Mass Flow Stan-
flow and pressure control.
• Useable with existing molbox1+ dard that makes the fundamental
and molbox RFM mass flow ter- molstic-L used for molboc-L measurement of low gas mass
minals and COMPASS software mass flow elements. flow rates practical.
• Integrated filter to protect • Quick connector input • Covers the range of 0.2 to
against contamination • 2 micron (0.5 micron for low 200 mg/s in various gases
• Integral gas temperature condi- flow) filter to protect the (10 sccm to 10 slm N2)
tioning and measurement downstream components • Measurements can be trans-
• No moving parts that cause • Adjustable regulator protects ferred to higher flow ranges
pressure/flow fluctuations or the molbox transducers using Successive Addition
threaten reliability molstic-S used for molbloc-S method
mass flow elements. • Flow measurement uncertainty
• Available in 1/2 inch or 1/4 as low as ± 0.013 % of reading
inch system plumbing sizes
• Integrated flow shut-off/
metering valves
38 Gas Flow Calibration www.flukecal.com
Calibration software
“Calibration software” refers to applications that Efficiency—Automating the calibration process
automate all or part of a calibration process via allows technicians to set up tests and then go on
computer control. Calibration software also allows to perform other tasks, making more efficient use
users to manage their calibration and asset data. of their time. Calibrations are typically completed
If you’ve heard about the benefits of automated much more quickly, saving time and money. If the
calibration and asset management but are puzzled software is capable of calibrating multiple units
about how everything fits together, call on Fluke under test simultaneously, automation increases
Calibration for solutions. throughput as well.
Other types of calibration software from
Fluke Calibration include data-logging software, Documentation and reports—Calibration auto-
software that generates calibration constants mation software typically includes features for
and references, and various add-on and plug-in documenting calibration procedures, storing cali-
software programs. bration data, and producing reports, allowing users
to eliminate paper records or spreadsheets.
Why use calibration software?
Because Fluke Calibration software does such a
Using software to automate all or part of the good job of keeping accurate records of all parts of
calibration process offers several important the calibration process, it also supports compliance
advantages. with a wide variety of quality standards.
Consistency—Software automation ensures that
calibrations can be performed exactly the same
way by multiple operators in multiple locations.
This improves the quality of results, reduces errors
and standardizes methods.

www.flukecal.com Calibration Software 39


Product highlights

MET/TEAM® Test Equipment Asset MET/CAL® Plus Calibration


Management Software Management Software

MET/TEAM® software is a powerful, flexible, and MET/CAL Plus software automates the calibration
scalable calibration management software solution process to help you manage your workload more
for managing your calibration assets. Designed by efficiently and consistently. The MET/CAL suite
metrologists for metrology, it is ideal for calibra- of applications includes MET/CAL software, the
tion professionals who need to manage workflow industry leader for automated calibration; plus
through the calibration laboratory. MET/TEAM software for asset management.
• Browser-based software enables access that is MET/CAL Plus software provides you with the
convenient, yet secure tools you need to:
• Fully featured for tracking and managing assets • Perform automated calibration on all kinds of
• Fully integrated with the Run Time function of test and measurement tools and equipment,
industry leading MET/CAL® software including dc/lf, RF and microwave instruments
• Replaces MET/TRACK as the recommended data- • Create, edit, test, and document calibration
base engine for MET/CAL software procedures, quickly and easily
• Popular Microsoft SQL server database for reli- • Configure and report a wider range of mea-
able, affordable, non-proprietary data storage surement uncertainty parameters and include
• Workflow management verification data to provide an audit trail and
• Highly customizable fields and labels support further analysis
• Shortcuts (quick links) for easy navigation • Track asset information including calibration
• Promotes quality processes to support and maintenance history and status, traceability,
accreditation users, customers, and location
• Customizable reports with Crystal Reports • Analyze and report asset information; produce
Professional customized printed certificates and reports.
• Automated email alerts and recall escalation • Make data available to other corporate systems
• Mobile module for on-site calibration • Import asset and calibration data into
• Customer web portal to allow read-only access MET/CAL Plus software
for remote customers • Help meet the requirements of quality standards
• Commerce module for quoting, billing, and like ISO 9000, ISO/IEC 17025, NRC 10 CFR, ANSI
contract pricing Z540.3, and others
• Designed for metrology by metrologists
• Backed by Fluke Calibration, expert in calibra-
tion instrumentation and software
• Collect and store manual calibration data

40 Calibration Software www.flukecal.com


Warranted Procedures for MET/CAL

MET/CAL®

Electrical/RF
calibration
software
MET/CAL®
5080A/CAL
The complete solution for auto-
mating calibration processes plus
managing and reporting mea-
surement assets. MET/SUPPORT
• Perform fast, repeatable, and
powerful calibration Software support
• Full storage of calibration data programs
• Rich reporting capabilities
• Configure and report a wider MET/SUPPORTSM Gold
range of measurement uncer- Annual support programs for
tainty parameters MET/TEAM
MET/CAL and MET/TEAM soft-
Warranted Procedures for Calibration asset ware. These premier support
services help you maximize your
MET/CAL® management software investment.
Fully tested, ready-to-go proce- software • Premium support and services
dures designed to satisfy your to help you maximize produc-
needs. MET/TEAM Test Equipment tivity with MET/CAL and
• Optional calibration procedures Asset Management Software MET/TEAM software
for MET/CAL ® Plus Calibration Manage more workload with less • Access to warranted procedure
Software work with MET/TEAM software. library
• Warranted by Fluke Calibration • Browser-based calibration • Prioritized technical support
to produce valid calibrations asset management software • Software updates and upgrades
on the intended unit under test • Fully integrated with MET/CAL® • Priority web content
(UUT) for the specified model Software • Discounts on a variety of
and revision level • Microsoft SQL Server database services
• These procedures automate • Highly customizable
the calibration process under • Email automation Software Training
MET/CAL control • On-site calibration and Services
• Work flow management A range of services to help you
5080A/CAL • Pricing/billing/invoicing maximize your investment in
Easy-to-use standalone software • Customer web portal calibration software.
for the 5080A Multi-Product • Installation and training • MET/TEAM software installa-
Calibrator. services tion and startup
• Quickly calibrate a wide range • MET/TEAM data migration and
of analog and digital workload import
• Provides automated control • Classroom or onsite training
of the calibrator; technician classes:
simply enters readings from – MET/CAL procedure writing
the item being calibrated – Advanced procedure writing
• Easy-to-use procedure – M ET/TEAM Asset
designer; simply select the Management
type of signal needed to per- – Crystal Reports Writing
form a test from a drop-down • Custom MET/CAL procedures
menu, enter the test level and • MET/TEAM self-validation
set the test limits • Custom software services
www.flukecal.com Calibration Software 41
9938 MET/TEMP II Temperature LogWare
Calibration Software v5

Temperature TQSoft and TQAero Thermal


calibration software Validation Software

9938 MET/TEMP II
Temperature Calibration LogWare
Software v5 Turn a Fluke Calibration
New version of the proven solu- single-channel handheld or
tion for automated temperature 1502A/1504 readout into a real-
calibration time data logger. LogWare II
• Compatible with Windows 7 • Collects real-time data
and 8 operating systems • Calculates statistics and dis-
• Adds support for 9190A Field plays customizable graphs
Metrology Well and 9118A • Allows user-selected start
Thermocouple Furnace times, stop times and sample
• Calibrate PRTs, SPRTs, therm- intervals
istors, thermocouples, and
even liquid-in-glass (LIGs), LogWare II
bi-metallic thermometers, and Turn any Fluke Calibration
connected sensors that can’t multi-channel thermometer read-
be attached to a readout out into a real-time data logger.
• Supports multiple temperature • Collects real-time data using LogWare III
sources and reference probes Fluke Calibration multi-chan-
in the same test for faster nel readouts
calibration and extended test • Calculates statistics and dis-
range plays customizable graphs
• Allows user-selected start
TQSoft and TQAero Thermal times, stop times and sample
Validation Software intervals
For FDA 21 CFR Part 11 and AMS
2750 Compliant Data Collection LogWare III
• Support for Fluke 2638A and Remotely monitor and log a
1586A, for enhanced data virtually unlimited number of
collection and reporting in concurrent log sessions into a
regulated industries central data repository.
• Easy menu system and toolbar • Up to two temperature and
• Test equipment preparation two humidity inputs for each
and sensor calibration DewK
• Data security, audit trail, and • Customize your graph trace
compliance reports color, alarms, and statistics as
you go

42 Calibration Software www.flukecal.com


COMPASS for Pressure

Pressure/Flow COMPASS for Pressure


calibration software
COMPASS® for Pressure COMPASS® for Flow
Universal platform for automating Macro-enabled mass flow cali-
pressure calibration. bration software package.
• Integrated piston gauge • Fully customizable
support • Supports non Fluke Calibration
• Runs complete automated flow references
calibration sequences • Performs complex real time
• Supports multiple units under flow computations, and allows
test you to alter test scenarios
• Automates virtually any based on data collected
pressure standard or device
COMPASS for Flow
under test

www.flukecal.com Calibration Software 43


Data acquisition and
general purpose test equipment

Data acquisition equipment General purpose test equipment


Get the data you want, where, how and when you Fluke Calibration designs and manufactures
want it. Fluke gives you a broad choice in data bench instruments in a wide variety of prod-
acquisition for process monitoring and laboratory uct categories. Besides their use on the bench,
test systems. You can choose a stationary or por- these instruments have several character-
table data logger. Transfer data to internal memory, istics in common as you will find below:
to a removable memory card, or to your PC. Choose • Each bench instrument is accurate and provides
a standalone or distributed networked units. And precise information. They reflect the profession-
you can expand your system from 20 to 1,000+ alism of the people who buy and use them.
channels, depending on the series. • Each is reliable, dependable, and rugged.
All Fluke data acquisition products feature • All are easy to operate. Many owners of Fluke
unique, built-in universal signal conditioning and bench instruments say that the controls are
a plug-in Universal Input Module to enable you intuitive and help them work more efficiently.
to measure virtually any type of signal without • These bench instruments are compact and easily
having to purchase extra equipment. Plus, pow- transported, but they are also multi-functional.
erful, easy-to-use Windows®-based software • You will find that these instruments are a good
supports easy configuration, advanced trend anal- value, particularly when compared against other
ysis, professional-quality reporting, and enables tools for their cost/function ratio.
you to quickly build human-machine-interfaces
without any programming.

44 Data Acquisition www.flukecal.com


Product highlights

2638A Hydra Series III Data Fluke DAQ 6.0 Application Software
Acquisition System
A powerful and versatile application
A price performance breakthrough in for quick and easy configuration,
standalone data acquisition system data logging and analysis using
The Fluke Hydra Series III continues the Hydra Fluke data acquisition products
Series legacy in data acquisition. This new Hydra Fluke DAQ is praised by users for its versatile
Series improves on the long standing, industry handling of data acquisition and logging. Improved
leading specification of best-in-class thermocouple trending, file handling, added web interface, web
accuracy. With basic dc measurement accuracy control, convenient print functions for charts and
of 0.0024 %, 0.5 °C thermocouple accuracy, color graphs and multiple language improvements make
trend display, easy-to-use menu system and world- Fluke DAQ version 6 a feature-rich application that
class industrial safety ratings, the 2638A is a truly you can trust with your important data and analy-
industrial grade, precision data acquisition system. sis needs.
Expandable from 22 to 66 channels of analog
differential measurement, the Hydra 2638A offers Fluke DAQ features easy multi-unit
the flexibility of our Universal Input Connector, configuration, data logging and analysis
which allows quick connect and disconnect of any for any of these products:
type of input to any channel. AC and dc voltage, • 2638A Hydra Series III Data Acquisition
resistance, thermocouple, RTD, thermistor, fre- System/Digital Multimeter
quency and dc and ac current are all selectable • 1586A Super-DAQ Precision Temperature Scanner
inputs for the 2638A. If your measurement need is • 2640A and 2645A NetDAQ® Networked Data
from under twenty channels to over sixty-six chan-
Acquisition Units
nels per unit or thousands of channels per system,
• 2680 Series Data Acquisition Systems
we have you covered.

• DC accuracy of 0.0024 %
• Best-in-class thermocouple accuracy of 0.5 °C
• Up to 67 universal differential, isolated inputs
• On-screen color trend graphing
• Easy menu system for setup and data
management
• Multi-channel real-time data display
• 6.5 digit DMM function selections
• Monitor function for real-time viewing and chart-
ing between scans
• 20 on-board separate math channels
• 45 channels/sec basic dc scan rate
• Internal 75,000 scan memory plus USB drive port
• Data security features
• CAT II 300 V input safety rated

www.flukecal.com Data Acquisition 45


2638A 2686A NetDAQ (2640)

Data acquisition equipment


2638A Hydra Series III Data 2680 Series Data NetDAQ® Networked Data
Acquisition System/DMM Acquisition Systems Acquisition Unit
A price performance break- Standalone or networked Powerful combination of hard-
through in standalone data precision multi-channel data ware and software that is ideal
acquisition system. acquisition for small-to-medium scale pro-
• DC accuracy of 0.0024 % • 20 to 120 universal analog cess monitoring and test systems.
• Best-in-class thermocouple inputs per chassis; systems to • Data acquisition, up to
accuracy of 0.5 °C +2,000 channels 1,000 readings per second
• Up to 67 universal differential, • Stand-alone data logger opera- • 20 analog input channels
isolated inputs tion with the 2686A expandable up to 2,000
• On screen color trend graphing • Large scalable LAN sys- channels
• Easy menu system for setup tems using the 2680A with • Extensive optional plotting
and data management 10BaseT/100BaseT and trending capabilities
• 6.5 digit DMM function • Two types of Universal Input • Includes Fluke DAQ software
selections Modules: high-isolation preci- • Flexible ac or dc power
• Monitor function for real-time sion modules or fast scan • Replaces chart recorders
viewing and charting between modules, with 16- to 18-bit
scans resolution Fluke DAQ 6.0
• 20 on-board separate math • Throughput of more than Application Software
channels 3,000 channels-per-second-
• 45 channels/sec basic dc per-chassis with 2680A-FAI A powerful and versatile
scan rate modules application for quick and
• Internal 75,000 scan memory • Superior thermocouple mea- easy configuration, data log-
plus USB drive port surement accuracy (J, K, R, S, ging and analysis using Fluke
• Expands to thousands of chan- T, N, I, U, C, B) data acquisition products.
nels with application software • 20 digital I/O and 8 form C, 1 • Easy multi-unit configuration for
• Data security features Amp relay output modules for any mix of Fluke 2638A, 1586A,
• USB flash drive support for direct control of equipment NetDAQ or 2680 Series
data transfer to PC • Up to 300 V input isolation, • Full screen trend charting of up
• CAT II 300 V input safety rated 1600 V transient overvoltage to 32 channels with zoom, print
protection (2680A-PAI) and scaling functions
• Universal input conditioning for • Built-in OPC server software for
any input, on any channel, in sharing Fluke DAQ data with
any combination (V dc, V ac, popular client programs
Ohms, frequency, RTD, thermo- • Logon security features
couple, thermistor or current • Auto start on power interrupt
• ATA flash memory card for settings
stand-alone operation - from • Master/slave configurations
16 MB to 1 GB (2686A only) available
• Multiple power sources: 100 V • Alarm logging with history with
to 240 V and 9 V to 45 V dc acknowledgement features
• Includes Fluke DAQ Software: • Four web clients for remote
Controls all 2680 Series func- viewing and control of systems
tions, provides real-time and using secure login
historical and also communi- • Automated email of alarm alerts
cates with NetDAQ and Hydra • Up to 2000-channel capability
Series III products • Runs on a variety of operating
Fluke DAQ 6.0 systems including Windows 7
and 8
46 Data Acquisition www.flukecal.com
8845A/8846A

8808A 271 290 280

General purpose test equipment 290 Series Waveform


Generators
8845A/8846A 6.5 Digit 8808A Digital Multimeter One, two, or four channel
Precision Multimeters Versatile multimeter for manufac- 100 MS/s waveform generators.
Precision and versatility for turing, development and service • 100 MS/s 12-bit arbitrary
bench or systems applications. applications. waveform capability
• 6.5 digit resolution • 5.5 digit resolution • 1 M point waveform memory
• Basic V dc accuracy of up to • Basic V dc accuracy of 0.015 % • 40 MHz function generator
0.0024 % • Dual display capabilities using DDS (50 MHz
• Dual display • Dedicated dc leakage current for square waves)
• 100 μA to 10 A current range, measurement • 10 ns pulse pattern generator
with up to 100 pA resolution • 2x4 ohms 4-wire measurement • Waveform sequencing with up
• Wide ohms range from 10 Ω technique to 1024 segments
to 1 GΩ with up to 10 μΩ • Six dedicated buttons for fast • Unlimited waveform storage
resolution access to instrument setups using CF® memory card
• 2 x 4 ohms 4-wire measure- • Hi/Lo limit compare for Pass/ • Waveform Manager Plus for
ment technique Fail testing Windows software
• Both models measure • Three-year warranty • USB interface in addition to
frequency and period RS-232 and GPIB
• 8846A also measures capaci- 271 DDS Function Generator
tance and temperature with ARB 280 Series Waveform
• USB memory drive port Generators
(8846A) High performance function
generator. Universal waveform generators
• Fluke 45 and Agilent 34401A
• High stability 10 MHz DDS offering superior performance
emulation
function generator and value.
• Graphical display
• Arbitrary capability with • Choice of 1, 2 and 4 indepen-
• Trendplot™ paperless recorder
storage for five user defined dent or linked channels
mode, statistics, histogram
waveforms • 40 MS/s max. sampling speed
• CAT I 1000 V, CAT II 600 V
• Multiple standard and complex • 16 MHz function generator
• Three-year warranty
waveforms recalled from inter- • 10 MHz pulse generator
nal memory • Pulse train pattern generator
• Extensive modulation capabili- • Arbitrary waveforms of up to
ties include sweep, AM, Gating, 65 k points
Trigger/Burst, FSK and Hop • Powerful modulation
• GPIB and RS-232 interfaces capabilities
• Built-in trigger generators
• Waveform Manager Plus for
Windows® software
• Multiple standard waveforms
recalled from internal memory
• RS-232 and GPIB interfaces

www.flukecal.com General Purpose Test 47


Service programs Instrument CarePlan Instrument CarePlan

Priority Gold Instrument CarePlan* Silver CarePlan


An instrument CarePlan from Fluke Calibration that guarantees your calibrator Extended warranty for your
is ready to work when you are. Fluke Calibration instrument
When your calibrator is out of your lab for scheduled calibration or unexpected Repairs are always unexpected,
repair, it isn’t working for you. What’s worse, you may not know exactly when to and they can be costly. Control
expect it back in your lab. With the Fluke Calibration Priority Gold CarePlan, you your cost of ownership with a
can schedule your calibrations and reduce repair downtime effectively, because you Fluke Calibration Silver CarePlan.
will know exactly when to expect your calibrator back in your lab. Your Priority Gold The Fluke Calibration Silver
CarePlan puts you in control of your downtime and in control of your business. CarePlan is a comprehensive
instrument warranty support
Priority Gold CarePlan features: plan that puts you in charge of
• Annual calibration included with guaranteed in-house turnaround of three or six your operating costs and protects
business days your investment in your new
• Free repairs with guaranteed in-house repair time of ten business days (includes Fluke Calibration instrument.
calibration)
• Prepaid, priority freight on return of instrument Silver CarePlan basic features:
• Free product updates for the product covered by the Priority Gold CarePlan • Extended warranty coverage
• Term: one, two, three, four and five year plans available for your instrument
• 10 % off Priority Gold CarePlans with the purchase of a new Fluke Calibration • Calibration included on repairs
instrument covered by your plan
• 10 % off on product upgrades for the product covered by the Priority Gold CarePlan • 15 % discount on regular
• 15 % off any out-of-plan service charges for the product covered by the Priority calibrations during your factory
Gold CarePlan and Silver CarePlan term
• 20 % off any Fluke Calibration scheduled metrology training for any of your • 15 % discount on any out-of-
personnel plan services
• Free product updates (PCNs)
*Not available in all countries. Contact your local Fluke representative for more details. performed at the time of repair

48 Service and training www.flukecal.com


Self-paced training tools
In addition to self-paced online
training, Fluke Calibration offers
additional self-paced training
tools for dc/low frequency metrol-
ogy. Fluke Calibration offers the
only comprehensive text book
on dc/low frequency metrology,
Calibration: Philosophy in Prac-
Register your Fluke Instructor-led classroom
tice, Second Edition. It covers real
Calibration product online courses world concepts and applications,
Visit www.flukecal.com/ Our instructor-led courses cover and is designed and written for
register-product to register your a variety of metrology topics and the working technician.
product today! range from one to five days in
length. Held in various locations On-site training
Authorized Fluke Calibration around the world, training from Fluke Calibration instructor-led
Service Centers Fluke Calibration is a great way courses may also be taught at
Fluke Calibration offers calibration to maximize your investment in your facility. If you have a large
and repair services and support your calibration equipment. number of students, or if the
through our flagship metrology material you wish to discuss
Instructor-led web-based is considered confidential, you
laboratories and service partners
worldwide. To find the best solu-
training may find On-Site Training an
tion for your calibration product Our instructor-led web-based attractive alternative. Contact
you can visit www.flukecal.com/ trainings offer the same great your local Fluke Calibration
service-centers, or email us at access to Fluke Calibration representative to discuss specific
service@flukecal.com. experts, with the added benefit requirements and arrangements,
of not having to travel. Instruc- or email training@flukecal.com
tor-led web-based trainings are
Training designed to fit into your sched-
for a Fluke Calibration represen-
tative to contact you.
Calibration and metrology train- ule, without disrupting your For an up-to-date course
ing from Fluke Calibration can workflow. Courses are set up in schedules, and pricing, and
help you and your staff become anywhere from one to five parts, training resources visit:
more knowledgeable in a wide two hours each, held on consecu- www.flukecal.com/training
variety of disciplines. Instructors tive days.
are experts who work in electri- Installation and training
cal, temperature, pressure and flow supplemental services
calibration, and who really want to
Self-paced online training
help you learn the foundation and Our self-paced calibration and Fluke Calibration offers expert
techniques of metrology that you metrology training courses were consulting to help you configure
can put to immediate use in your developed by technical experts and use your calibration products
workplace. Fluke Calibration offers in the metrology community as productively and cost-effec-
introductory, intermediate, and using proven instructional design tively as possible. We can help:
advanced level courses in a variety components. At the start of each • Minimize downtime
of formats to meet your needs. module, a brief tutorial describes • Make sure your equipment
how the course is laid out. The runs efficiently
learning objectives are clearly • Confirm that systems are oper-
stated. Topics are selected from ating properly
easy-to-navigate menus and • Train you and/or your staff at
sub-menus. Embedded ques- your site, a separate site, at
tions are presented frequently Fluke Calibration or online
to increase retention. Engaging
graphics, photos, formulas and
tables support text material. A
final post-test provides proof of
competency. Tests are shuffled
after each use. Most importantly,
a certificate of completion satis-
fies documentation requirements.

www.flukecal.com Service and training 49


Fluke Calibration. Precision, performance, confidence.™

Fluke Calibration Fluke Europe B.V.


PO Box 9090, PO Box 1186, 5602 BD
Everett, WA 98206 U.S.A. Eindhoven, The Netherlands
Web access: http://www.flukecal.eu
For more information call:
In the U.S.A. (877) 355-3225 or Fax (425) 446-5116
In Europe/M-East/Africa +31 (0) 40 2675 200 or Fax +31 (0) 40 2675 222
In Canada (800)-36-FLUKE or Fax (905) 890-6866
From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116
Web access: http://www.flukecal.com
©2011-2015 Fluke Calibration. Specifications subject to change without notice.
Printed in U.S.A. 12/2015 4026225f-en Pub-ID:12124-eng B

Modification of this document is not permitted without written permission


from Fluke Calibration.

Vous aimerez peut-être aussi