Académique Documents
Professionnel Documents
Culture Documents
Electrical
RF Temperature
Pressure
Flow
Software
Table of contents
2 Electrical
calibration 11 Temperature
calibration
9
High performance furnace for thermocouple
RF calibrations to 1200 °C.
calibration Page 12
www.flukecal.com
26 Pressure
calibration 39 Calibration
software
44
Page 27 Data acquisition
and general purpose test
3130 Portable Pressure Calibrator
Everything you need for accurate calibration of
pneumatic field instrumentation, in a rugged case Featured products
suitable for harsh industrial environments.
Page 27 2638A Hydra Series III Data Acquisition System
A price performance breakthrough in standalone
data acquisition system.
Page 45
Service programs.........................................48
Training...........................................................49
www.flukecal.com
Electrical calibration
Electrical calibration refers to the process of test (UUTs). Because these precise devices have
verifying the performance of, or adjusting, any thoroughly known performance characteristics
instrument that measures, sources, or tests compared to the UUT, performance evaluation
electrical parameters. This discipline is usually and/or calibration adjustment of the UUT to
referred to as dc and low frequency ac electrical identify or minimize errors is possible. Typically,
metrology. Principal parameters include voltage, the performance of such precision devices should
current, resistance, inductance, capacitance, be four or more times better than the UUT.
time and frequency. Other parameters, including These precision devices fall into two broad
electrical power and phase, are also in this categories. Electrical signal sources are often
segment of metrology. Ratiometric comparisons of referred to as either calibrators or standards.
similar parameters are often performed to compare Precision measurement devices are often classified
a known parameter to an unknown similar as reference digital multimeters, measurement
parameter. standards, or ratio bridges.
Electrical calibration involves the use of precise
devices that evaluate the performance of key
properties for other devices called units under
Workload 5080A 5502A 5522A 5730A 9500B 5320A 6003 6100B 6105A 525B 7526A
Analog/panel meters
High burden meters
Low burden meters V dc & V ac V dc, I dc & R V dc, I dc & R
DMMs
Basic dc V accuracy 100 ppm 50 ppm 11 ppm 3.5 ppm n/a 0.10 % 375 ppm 112 ppm 42 ppm 40 ppm 40 ppm
3.5 digits V dc & V ac V dc, I dc & R V dc & V ac
(typ. ± 0.3 % dc V)
4.5 digits
(typ. ± 0.025 % dc V)
5.5 digits
(typ. ± 0.015 % dc V)
6.5 digits
(typ. ± 0.0024 % dc V)
7.5 digits
(typ. ± 12 ppm dc V)
8.5 digits
(typ. ± 3.9 ppm dc V)
Temperature/pressure
RTD simulate
RTD measure
Thermocouple
simulate
Thermocouple
measure
Pressure modules opt opt opt
Two-wire
transmitters
Oscilloscopes 1 to 5 channels
300 MHz or
200 MHz to 200 MHz 600 MHz
600 MHz 600 MHz 600 MHz std
opt opt
opt
1.1 GHz 1 GHz opt 9510 Head opt
3.2 GHz 9530 Head opt
6.4 GHz 9560 Head opt
25 ps fast edge 9550 Head opt
(14 GHz)
Safety testers
Hipot
Megohm meters MEG opt
Installation
PATs
Continuity MEG opt
Loop impedance
Leakage current
Ground bond
RCD/GFCI
Medical safety
Power/energy
Wattmeters
Harmonic analyzers PQ opt
Flicker meters PQ opt PQ opt
Phase angle meters PQ opt
Power analyzers PQ opt PQ opt
Power recorders
Secondary energy
standards
Watthour/
E opt
energy meters
Other
52120A
5500A/ 5500A/ 5500A/ 52120A Amp
Clamp meters Amp +
COIL COIL COIL + COIL opt
COIL Opt
LCR meters RC only RC only
Process calibrators
Data acquisition
Non sine waveforms
30/50 MHz WB
RF millivolt meters
opts
# of calibrator
8 11 11 5 11+ 9 8 8 9 9
functions
5522A
DC/LF Electrical
Calibrators 5730A
5730A Multifunction
Calibrator
The new gold standard in
electrical calibration.
• The next generation high-
performance multifunction
calibrator
• Support instruments of up to 5502A 5080A
8.5 digits in measurement
performance
5522A Multi-Product 5080A High Compliance
• Artifact Calibration permits
Calibrator Multi-Product Calibrator
the lowest cost of support
and highest confidence in Robust, transportable wide work- Solutions for your analog and
performance load coverage. digital workload.
• New internal printed circuit • Calibrates a wide variety • High compliance for difficult-
boards with upgraded digital of electrical test equipment to-calibrate analog instruments
technology with more than 14 functional • Robust protection circuits
• 6.5 inch VGA capacitive capabilities prevent costly damage from
touchscreen with full color • Accuracies intended to support operator error
graphical user interface DMMs to 6.5 digits • Calibrates a wide workload,
• Menus and functions dis- • Robust protection circuits including analog meters and
played in choice of nine prevent costly damage from 3.5 and 4.5 digit DMMs
languages operator error • Options for oscilloscope and
• Optional wideband outputs • Optional oscilloscope calibra- megohm meter calibration
to 30 or 50 MHz tion to 1100 MHz
• Easy to transport
5502A Multi-Product
Calibrator
Robust, transportable solution to
match your workload and budget.
• Calibrates a wide variety of
electrical test equipment
• Robust protection circuits
prevent costly damage from
operator error
• Ergonomically designed
carrying handles
• Rugged optional case with
built-in handles and wheels
and removable front/rear
access doors
• Optional oscilloscope
calibration to 600 MHz
Electrical
Standards
732B/734A DC Reference
and Transfer Standards
910/910R 908/909
The simple way to maintain and
disseminate your volt.
• A primary standard for trace-
ability of dc voltage to better 742A Resistance Standard 720A Kelvin-Varley Divider
than 1 ppm High accuracy working standard A primary standard for ratio
• Complete mechanical and elec- for on-site resistance calibration. measurements.
trical independence of each of • Small and rugged standard • 0.1 ppm resolution, seven
its four standards (734A) resistors with six-month stabil- decades
• Battery powered for easy ities to 2.5 ppm • 0.1 ppm of input absolute
shipping • Open air use so no oil or air linearity
baths required • Built-in self-calibration bridge
792A AC/DC Transfer • 18 °C to 28 °C operating range
Standard • Standard values from 1 ohm to 910/910R GPS Controlled
100 Megohms Frequency Standard
Support for your most demanding
ac traceability requirements. A40B Series Precision Cesium controlled frequency
• A primary standard that is Current Shunts standard that uses GPS technol-
accurate, fast and easy to use ogy and connectivity to provide
• Fully traceable performance Precision, low inductance shunts
primary standard traceability
with ac/dc difference to better for dc and ac current metrology.
from any location.
than 10 ppm • Simplifies calibration/verifica-
• Unique traceability feature
• Nine ranges from 22 mV to tion of precision calibrators
means no more re-calibrations
1000 V (with external range and current sources
• Two high-stability models to
resistor) • Shunts sized for current from
meet your application and fit
1 mA to 100 A
your budget
• Usable from dc to 100 kHz
5790B AC Measurement • Built-in rubidium atomic clock
• Ultra low phase shift to sup-
Standard (910R)
port power quality instrument
• Up to 13 outputs, maximizing
Easiest way to make precision ac metrology
cost efficiency
measurements
• AC voltage measurement uncer- A40/A40A Current Shunts
tainties as low as ± 24 ppm • AC current transfer measure-
908/909 Frequency
• Works with A40B shunts for ments from 2.5 mA to 20 A References
making precise absolute and • Frequency between 5 Hz to Stable frequency references for
relative current measurements 100 kHz test systems and calibration labs.
without requiring manual • Accurate reference “atomic
current value calculations 752A Reference Divider clock” in automated test
• 30 MHz and 50 MHz wideband Setting the standard for ratio systems
range options accuracy and ease of use. • Affordable and very cost
• Statistics and peak-to-peak • Key standard for calibrating effective
waveform functions 57xx Series Calibrators • Designed for portability with
• Intuitive graphical interface • 10:1 and 100:1 divider outputs optional carrying case
• Visual Connection Manage- • Output uncertainty 0.2 ppm
ment™ terminals that light up and 0.5 ppm
to show the active terminals • Built-in calibration bridge
www.flukecal.com RF Calibration 9
96270A 96040A
RF References
96270A 27 GHz Low Phase 96040A Low Phase Noise
Noise Reference Source Reference Source
The simplest, most accurate and Simplify your RF calibration
cost effective single instrument system by replacing many of the
for calibrating spectrum analyz- instruments and accessories that
ers, RF power sensors and more. make up your current system.
• “Self-characterization” lets you • Covers a broad range of RF
avoid calculating correction calibration workload
factors for each component in • Reduces the number of instru-
the signal delivery system ments and interconnections
• “What you set is what you get” required for your RF calibra-
accurate signal delivery direct tion system
to the UUT input up to 27 GHz • “What you set is what you
• Covers a broad range of RF get” accurate signal delivery
calibration workload direct to the UUT input
• Reduces the number of instru- • Integrated 50 MHz frequency
ments and interconnections counter eliminates need for an
required for your RF calibration additional instrument
system • Calibration-specific interface
• Integrated 300 MHz frequency simplifies technician tasks
counter and dual power meter • Simplifies uncertainty calcula-
readout eliminate need for tions by delivering known
additional instruments signals direct to the unit
• Calibration-specific interface under test (UUT)
simplifies technician tasks • Lowers RF system mainte-
• Simplifies uncertainty nance costs
calculations • With automation, reduces
• Lowers RF system maintenance spectrum analyzer calibration
costs times by as much as 50 %
• With automation, reduces over manual methods
spectrum analyzer calibration
times by as much as 50 % over
manual methods
10 RF Calibration www.flukecal.com
www.flukecal.com
Temperature calibration
Temperature calibration refers to the calibration general categories of heat sources: industrial heat
of any device used in a system that measures sources (dry-well calibrators, Micro-Baths, etc.) for
temperature. Most importantly, this usually means field use; fluid baths and thermocouple furnaces for
the temperature sensor, itself, which is typically a laboratory use; and fixed-point cells for “primary”
platinum resistance thermometer (PRT or PT-100), calibrations. Fluke Calibration also offers a variety
thermistor, or thermocouple. Readings from these of reference thermometers, including SPRTs, and
thermometers are made by “thermometer readout” thermometer readout instruments.
devices which measure their electrical outputs In addition, Fluke Calibration provides laboratory
and convert them to temperature according to the and field solutions for calibrating the electronics
International Temperature Scale of 1990 (ITS-90). used in temperature measurement circuits.
Thermometers are typically calibrated by placing
them in a stable temperature environment (heat
source) and comparing their output to that of a
calibrated “reference thermometer” or “standard
thermometer.” Fluke Calibration provides three
5901D-Q TPW Cell, 12 mm ID, quartz shell 0.01 °C 7341 Maintains: triple point of mercury cell.
Comparisons: –45 °C to 150 °C.
5901B-G TPW Cell, mini, glass shell 0.01 °C
9210 Maintains: mini triple point of water.
Standard size fixed-point cells Comparisons: –10 °C to 125 °C.
5900E TP mercury, SST –38.8344 °C 9230 Maintains: stainless steel gallium cell.
Comparisons: 15 °C to 35 °C.
5904 Freezing point of indium 156.5985 °C
9260 Maintains: indium, tin, zinc, and aluminum cells.
5905 Freezing point of tin 231.928 °C Comparisons: 50 °C to 680 °C.
5906 Freezing point of zinc 419.527 °C 9114 Maintains: indium, tin, zinc, and aluminum cells.
Comparisons: 100 °C to 680 °C.
5907 Freezing point of aluminum 660.323 °C
9115A Maintains: aluminum and silver cells.
5908 Freezing point of silver 961.78 °C
Comparisons: 550 °C to 1000 °C.
5909 Freezing point of copper 1084.62 °C
9116A Maintains: aluminum, silver, gold, and copper cells.
5924 Open freezing point of indium 156.5985 °C Comparisons: 400 °C to 1100 °C.
5925 Open freezing point of tin 231.928 °C 9117 Anneals SPRTs, HTPRTs, and thermocouples to 1100 °C.
Protects them against contamination from metal ions.
5926 Open freezing point of zinc 419.527 °C
Boiling point of liquid nitrogen
5927A Open freezing point of aluminum 660.323 °C
7196 Affordable substitute for a triple point of argon system.
5928 Open freezing point of silver 961.78 °C Provides for low-temperature comparison calibrations at
5929 Open freezing point of copper 1084.62 °C approximately –196 °C with uncertainties of 2 mK.
5943 Melting point of gallium, SST 29.7646 °C Triple point of argon system
5960A Lowest uncertainty for any commercially available triple
Mini triple point of water and fixed-point cells point of argon system.
5901B Mini triple point of water 0.01 °C
Standard resistors
5914A Mini freezing point of indium 156.5985 °C
742A Excellent performance without oil or air baths.
5915A Mini freezing point of tin 231.928 °C Values from 1 ohm to 19 megohm.
5916A Mini freezing point of zinc 419.527 °C 5430 Highest stability oil-filled resistors (< 2 ppm/year drift).
AC cal uncertainty to 3 ppm.
5917A Mini freezing point of aluminum 660.323 °C
5918A Mini freezing point of silver 961.78 °C
5919A Mini freezing point of copper 1084.62 °C
5944 Mini freezing point of indium, metal cased 156.5985 °C
5945 Mini freezing point of tin, metal cased 231.928 °C
5946 Mini freezing point of zinc, metal cased 419.527 °C
5947 Mini freezing point of aluminum, metal cased 660.323 °C
Infrared calibrators
4180 –15 °C to 120 °C (5 °F to 248 °F) ± 0.40 °C at –15 °C
± 0.40 °C at 0 °C
± 0.50 °C at 50 °C
± 0.50 °C at 100 °C
± 0.55 °C at 120 °C
4181 35 °C to 500 °C (95 °F to 932 °F) ± 0.35 °C at 35 °C
± 0.50 °C at 100 °C
± 0.70 °C at 200 °C
± 1.20 °C at 350 °C
± 1.60 °C at 500 °C
9132 50 °C to 500 °C (122 °F to 932 °F) ± 0.5 °C at 100 °C
± 0.8 °C at 500 °C
9133 –30 °C to 150 °C (–22 °F to 302 °F) ± 0.4 °C
Metrology Wells
9170 –45 °C to 140 °C (–49 °F to 284 °F) ± 0.1 °C
9171 –30 °C to 155 °C (–22 °F to 311 °F) ± 0.1 °C
9172 35 °C to 425 °C (95 °F to 797 °F) ± 0.1 °C at 100 °C
± 0.15 °C at 225 °C
± 0.2 °C at 425 °C
9173 50 °C to 700 °C (122 °F to 1292 °F) ± 0.2 °C at 425 °C
± 0.25 °C at 660 °C
Zero point dry-well
9101 0 °C (32 °F) ± 0.05 °C
Dual block dry-well
9011 50 °C to 670 °C (122 °F to 1238 °F) ± 0.2 °C at 50 °C
± 0.4 °C at 400 °C
± 0.65 °C at 600 °C
–30 °C to 140 °C (–22 °F to 284 °F ) ± 0.25 °C (insert wells)
± 0.65 °C (fixed wells)
Thermocouple furnaces
9150 150 °C to 1200 °C (302 °F to 2192 °F) ± 5 °C
9118A 300 °C to 1200 °C (572 °F to 2192 °F) ± 5 °C
7312
Thermometer readouts
1586A Super-DAQ Precision 1529 Chub-E4 Standards
Temperature Scanner and Thermometer
DAQ-STAQ Multiplexer Lab-quality accuracy on four
1594A/1595A channels for PRTs, thermistors and
Best-in-class temperature mea-
surement accuracy and up to thermocouples.
40 isolated input channels for • Four channels for PRTs, thermis-
measuring RTDs, thermocouples, tors, and thermocouples
thermistors, dc voltage, dc • Displays eight user-selected data
current, and resistance. fields from any channel
• PRTs: ± 0.005 °C; • Logs up to 8,000 readings with
5430 Thermocouples: ± 0.29 °C; date and time stamps
Thermistors: ± 0.002 °C
• Scan speed of up to 10 chan- 1502A/1504 Thermometer
nels per second Readouts
• Real-time color trending— Best performance thermometers in
chart up to four channels their price range.
simultaneously • Single-channel reference
• Control Fluke Calibration thermometers
1560 temperature sources such as • Two models to choose from—
dry-wells or Micro-Baths for reading PRTs or thermistors
automated calibration routines • Best price/performance package
1594A/1595A Super- 1523/1524 Reference
Thermometers Thermometers
Thermometry bridge accuracy Measure, graph and record three
combined with time-saving sensor types with one tool.
1529
features. • High accuracy: PRTs: ± 0.011 °C;
• Calibrate SPRTs, PRTs, RTDs Thermocouples: ± 0.24 °C;
and thermistors (0 Ω to 500 kΩ) Thermistors: ± 0.002 °C
• Accuracy as good as 0.06 ppm • A simple user interface to see
(0.000015 °C) trends quickly
• “Ratio Self-Calibration” verifies • Smart connectors to load probe
and calibrates resistance ratio information automatically
1502A/1504 accuracy
1551A Ex and 1552A Ex
5430 Standard AC/DC “Stik” Thermometer
Resistor
The best substitute for precision
Best performance available in an mercury-filled glass thermometers.
ac/dc resistor. • Accuracy of ± 0.05 °C
• Long-term stability better than (± 0.09 °F) over full range
2 ppm/year (< 1 ppm typical) • Intrinsically safe (ATEX and
• Traceable ac and dc calibra- IECEx compliant)
tions available • Two models to choose from
• National lab design proven for (-50 °C to 160 °C or -80 °C to
more than 25 years 300 °C)
1523/1524
1560 Black Stack 1620A Digital Thermometer-
Thermometer Readout Hygrometer
Accurate, expandable and con- The most accurate temperature and
figurable readout. humidity graphical data logger on
• Reads SPRTs, RTDs, thermis- the market.
tors, and thermocouples • Superior accuracy
• Any configuration you like up • Network enabled
to eight modules • Powerful logging and
1551A Ex and 1552A Ex • High-accuracy reference ther- analysis tools
mometer (to ± 0.0013 °C)
20 Temperature Calibration www.flukecal.com
5608/5609 5616
5624
Secondary standard Thermistor standards Fast response PRTs
PRTs 5640 Series Thermistor 5622 Fast Response PRTs
5608/5609 Secondary PRTs Standards Probes Designed for temperature
Very stable thermometer from High accuracy temperature measurements requiring fast
–200 °C to 670 °C. probes with excellent stability. response or short immersion over
• 5608: –200 °C to 500 °C • Accuracy to ± 0.001 °C a wide range.
(80 mm minimum immersion) • Affordable system accuracy to • Time constants as fast as
• 5609: –200 °C to 670 °C ± 0.004 °C or better 0.4 seconds 5649/5650
(100 mm minimum immersion) • NIST-traceable calibration • Available as DIN/IEC Class A
• Calibration not included, included from manufacturer PRTs or with NVLAP-accredited
NVLAP-accredited calibration calibration, lab code 200348-0
optional, lab code 200348-0 High temperature PRT • Small probe diameters ranging
from 0.5 mm to 3.2 mm
5624 Platinum Resistance
5615 Secondary PRT Thermometer Small diameter
Reference-grade platinum industrial PRTs
Precision PRT accuracy at ther- 5627A
sensing element. 5618B Small Diameter
mocouple temperatures.
• –200 °C to 420 °C
• Temperature range of 0 °C to Industrial RTD
• ± 0.012 °C accuracy at 0 °C
1000 °C Secondary level performance
• Drift of ± 0.007 °C after 100
• Accuracy of ± 0.05 °C to with full ITS-90 calibration.
hours at max temperature
962 °C (includes short-term • Small diameter sheath, 3.2 mm
stability and calibration (0.125 in)
5626/5628 Secondary
uncertainty) • Excellent stability
SPRT, PRT, Temperature
• Long-term drift of 0.01 °C at • Includes ITS-90 coefficients
Sensors 0 °C after 100 hours at 1000 °C
5622
High-temperature secondary Full immersion PRTs
standards. Thermocouple 5606 Full Immersion PRT
• -200 °C to 661 °C standards
• Meets all ITS-90 requirements PRTs for laboratory freezers,
for resistance ratios 5649/5650 Type R and autoclaves, and furnaces.
• Rtp drift < 20 mK after 500 Type S Thermocouple • Transition junction designed
hours at 661°C Standards to withstand full temperature
Eight models to fit any type R or range of probe 5618B
Secondary reference S thermocouple applications. • 5606: -200 °C to 160 °C
PRTs • 0 °C to 1450 °C • Calibration accuracy of
• Two sizes available, each with ± 0.05 °C
5616 Secondary Reference
or without reference junction Secondary thermistor
PRT
• Optional fixed-point calibra- probes
• –200 °C to 420 °C tion, uncalibrated accuracy is
• Excellent stability: ± 0.007 °C the greater of ± 0.6 °C or 5610/5611/5611T/5665
• Calibrated accuracy ± 0.011 °C ± 0.1 % of reading Secondary Reference 5606
at 0 °C Thermistor Probes
Precision industrial PRTs Lab-grade thermistors probes for
accurate work across a narrow
5627A Precision Industrial
temperature range.
PRTs
• Short-term accuracy to
Durable PRTs with temperature ± 0.01 °C; one-year drift
range to 420 °C and accuracy to < ± 0.01 °C 5610/5611/
0.025 °C. • Accredited NVLAP calibration 5611T/5665
• Vibration and shock resistant optional
• NVLAP-accredited calibration • Flexible Teflon and silicone
included, lab code 200706-0 coated fast-response models
6330/7320/7340/7380
Compact Standard
calibration baths calibration baths
6330/7320/7340/7380 6020/6022/6024 High
Compact Temperature Temperature Calibration Oil
Calibration Baths Baths
Compact baths with the stabil- Stable, uniform heat sources for
ity and uniformity required for calibrations up to 300 °C.
thermometer calibration. • Stability as good as 0.001°C
• Stability and uniformity each • Large-capacity tanks for higher
better than ± 0.008 °C productivity
• Metrology-level performance in • Built-in cooling coils for
lab-friendly sizes external cooling sources
• Convenient use on benchtops
or on matching carts 6050H Extremely High
6331/7321/7341/7381 Temperature Calibration
6331/7321/7341/7381 Salt Bath
Deep-Well Compact Baths Designed for high-temperature
Ample immersion depth and calibration—up to 550 °C.
great stability, in a high value • Eliminates messy sand baths
compact bath. • Electronically adjustable
• 457 mm (18 in) of depth with temperature cutouts
just 15.9 liters (4.2 gal) of fluid • Stability of ± 0.008 °C at
• Perfect for liquid-in-glass ther- 550 °C
mometers with optional LIG kit
• Fast, quiet, compact (yet deep), 7008/7040/ 7037/
and economical 7012/7011 Cold
Temperature Calibration
7312 7312 Triple Point of Water Baths
Maintenance Bath
High stability means low calibra-
Keep your cells up and running tion uncertainties—no other bath
reliably for weeks at a time. performs this well.
• Maintains TPW cells for up to • Stability to ± 0.0007 °C
six weeks • Best digital temperature con-
• Optional immersion freezer for troller available
simple cell freezing • “Super Tweak” function pro-
• Independent cutout circuit vides set-point resolution to
protects cells from breaking 0.00003 °C
6050H
6054/6055/7007
7900
7009/7108/7015
Resistor Baths
Three size options for any quan-
tity of resistors.
• Stability to ± 0.0007 °C
• Independent high- and low-
temperature cutout circuit
P3032
P3023
P3022
P3025
P3031
P3012
P3013
P3015
P3014
P3011
Workload
Gauges/sensors
Gage
Bidirectional*
Pressure range
Vacuum
90 % vacuum
Positive gage pressure
5 inH₂O (1.5 kPa)
12 inH₂O (3 kPa)
1.5 psi (10.3 kPa)
2 psi (13.8 kPa)
2.2 psi (15 kPa)
3 psi (20.7 kPa)
5 psi (34.4 kPa)
10 psi (68.9 kPa)
15 psi (103.4 kPa)
20 psi (137.9 kPa)
30 psi (200 kPa)
40 psi (275.8 kPa)
100 psi (.7 MPa)
150 psi (1 MPa)
200 psi (1.4 MPa)
300 psi (2 MPa)
500 psi (3.4 MPa)
600 psi (4 MPa)
1000 psi (7 MPa)
2000 psi (14 MPa)
Accessories
Hand pump
Fine Inc. Weights
P3112
P3113
P3114
P3115
P3116
P3123
P3124
P3125
P3830
P3840
P3860
P3211
P3213
P3214
P3223
P3224
140M
200M
140M
200M
70M
14M
20M
40M
70M
7M
Fluid type
Oil
Water
Workload
Gauges/sensors*
Gage
Pressure range
10 psi (68.9 kPa)
15 psi (103.4 kPa)
20 psi (137.9 kPa)
30 psi (200 kPa)
40 psi (275.8 kPa)
100 psi (.7 MPa)
150 psi (1 MPa)
200 psi (1.4 MPa)
300 psi (2 MPa)
500 psi (3.4 MPa)
600 psi (4 MPa)
1000 psi (7 MPa)
2000 psi (14 MPa)
3000 psi (20 MPa)
5000 psi (35 MPa)
6000 psi (40 MPa)
10000 psi (70 MPa)
16000 psi (110 Mpa)
20000 psi (140 MPa)
30000 psi (200 MPa)
40000 psi
(275.8 MPa)
60000 psi (400 MPa)
PG7202 PG7000-AMH
PG7102
Piston gauges PG7202 High Pressure Gas 2465A Absolute Gas Piston
Piston Gauge Gauge
PG7601 Absolute Gas Piston Gas piston gauge with oil-lubri- Gas piston gauge capable of very
Gauge cated piston-cylinder for operation low pressures, for defining gauge
Gas piston gauge with vacuum in high pressure gas or oil. and absolute pressures.
reference for defining absolute • Gas pressures from 100 kPa to • Gas pressure from 1.5 kPa to
pressures. 110 MPa (15 to 16,000 psig), 7 MPa (0.2 psi to 1000 psi)
• Gas pressure from 5 kPa to oil pressures from 100 kPa to gauge or absolute pressure
7 MPa (0.7 psi to 1000 psi) 200 MPa (15 to 30,000 psig) • Lightweight, compact system
gauge or absolute pressure • Gas operated, liquid lubricated with small masses for reduced
• Onboard measurement of test for robust operation and low bench space, transportability
conditions, and real-time piston sink rates and ergonomic mass handling
calculation and display of test • Onboard measurement of test • Compatible with WinPrompt
pressure conditions, and real-time and COMPASS software
• Compatible with PPC4 pres- calculation and display of test
sure controller and AMH-38 pressure 2470 Gas Piston Gauge
Automated Mass Handler • Compatible with PPCH-G pres- Gas piston gauge capable of very
sure controller and AMH-100 low to high gauge pressures.
PG7102 Gas Piston Gauge Automated Mass Handler • Pressures ranges from
Gas piston gauge with 55 kg 1.5 kPa to 20 MPa (0.2 psi
mass set for extended range mea-
PG7302 Piston Gauge to 3000 psig)
surement of gauge pressures. Oil piston gauge for measurement • Lightweight, compact system
• Gas pressures from 100 kPa of high gauge pressures. with small masses for reduced
to 11 MPa (15 to 1,600 psig) • Oil pressures from 100 kPa to bench space, transportability
• Onboard measurement of test 500 MPa (15 psi to 75,000 psig) and ergonomic mass handling
conditions, and real-time • Onboard measurement of test • Compatible with WinPrompt
calculation and display of test conditions, and real-time and COMPASS software
pressure calculation and display of test
• Compatible with PPC4 pres- pressure
sure controller and AMH-100 • Compatible with PPCH pres-
Automated Mass Handler sure controller and AMH-100
Automated Mass Handler
PG7000-AMH Automated
Mass Handler
Automated Mass Handler for
PG7000 Piston Gauges.
• Add to PG7000 Series piston
gauge to fully automate
pressure testing in gauge or
absolute mode
• Designed and tested to provide
years of reliable, maintenance
free operation
• Reduce wear and possible
mass value changes caused by
manual mass handling
GPC1
Manual pressure
generation
and control
3990 Gas Pressure Control
Pack
Precise, manual absolute and
gauge pressure control for gas
MPG2
piston gauges and indicators.
2482 • Models from vacuum to 7 MPa
and 20 MPa (1000 psi and
3000 psi)
• Self-contained for intuitive,
easy use
* Can be used with the 2700G Reference Pressure Gauge to provide a complete calibration solution
7250sys
molstic-S
MFC Switchbox
molboc-L
molbloc-S Sonic Nozzle
Flow Element
Sonic nozzle based molblocs for
gas flow up to 5,000 slm.
• Covers ranges up to 5,000 slm
molbloc-S in N2 and air
• Multiple gases supported
• Useable with molbox1+, or
existing molbox1 and molbox
RFM mass flow terminals and
COMPASS software GFS™
• Proven critical flow ven-
molbox RFM turi (sonic) nozzle operating Gas Flow Automation
principle traceable to primary Accessories
Gas flow standards gravimetric flow measurements MFC-CB™ Control Box
molbox1+ Flow Terminal molbox RFM Reference Flow
Stand-alone unit for setting/
0.125 % of reading—lowest uncer- reading analog mass flow
Monitor controllers (MFCs) and mass
tainty for gas flow calibration.
Compact terminal for making mass flow meters (MFMs).
• Allows coverage of flow range
flow measurements using molbloc-L • Set and read 0 to 5 V or 4 to
from less than 1 sccm to over
and molbloc-S flow elements. 20 mA on two (2) channels
5000 slm with a single user
• Economical alternative to • Complete front panel local
interface and transportable
molbox1+ terminal control and remote operation
system
• ± 0.5 % of reading uncertainty via RS-232 and IEEE-488
• Real-time flow measurements
• Covers the flow range of 1 sccm interfaces
makes adjusting analog flow
to 100 slm with molbloc-L, and MFC Switchbox™
devices fast and easy
up to 5000 slm with molbloc-S Supplies power and switches
• Perform fully-automated flow
• 5141/5142/5144 kits feature between up to five MFCs or
calibrations using molbox ter-
molbox RFM, molbloc-L and MFMs on one molbox1+ or
minal with COMPASS for Flow
other hardware for a complete MFC-CB channel.
software
calibration system • Duplicates MFC channel
• Updated design
• No moving parts that cause without switching cables
molboc-L Laminar Flow pressure/flow fluctuations or
threaten reliability
Element Primary gas
Laminar flow elements for flow molstic Mounting Systems flow standard
from 1 sccm to 100 slm.
• Traceable to primary gravimet- Used to conveniently mount and GFS Dynamic Gravimetric
ric mass flow measurements protect molbloc elements, connect Mass Flow Standard
• Multiple gases supported to units under test and provide
True Primary Mass Flow Stan-
flow and pressure control.
• Useable with existing molbox1+ dard that makes the fundamental
and molbox RFM mass flow ter- molstic-L used for molboc-L measurement of low gas mass
minals and COMPASS software mass flow elements. flow rates practical.
• Integrated filter to protect • Quick connector input • Covers the range of 0.2 to
against contamination • 2 micron (0.5 micron for low 200 mg/s in various gases
• Integral gas temperature condi- flow) filter to protect the (10 sccm to 10 slm N2)
tioning and measurement downstream components • Measurements can be trans-
• No moving parts that cause • Adjustable regulator protects ferred to higher flow ranges
pressure/flow fluctuations or the molbox transducers using Successive Addition
threaten reliability molstic-S used for molbloc-S method
mass flow elements. • Flow measurement uncertainty
• Available in 1/2 inch or 1/4 as low as ± 0.013 % of reading
inch system plumbing sizes
• Integrated flow shut-off/
metering valves
38 Gas Flow Calibration www.flukecal.com
Calibration software
“Calibration software” refers to applications that Efficiency—Automating the calibration process
automate all or part of a calibration process via allows technicians to set up tests and then go on
computer control. Calibration software also allows to perform other tasks, making more efficient use
users to manage their calibration and asset data. of their time. Calibrations are typically completed
If you’ve heard about the benefits of automated much more quickly, saving time and money. If the
calibration and asset management but are puzzled software is capable of calibrating multiple units
about how everything fits together, call on Fluke under test simultaneously, automation increases
Calibration for solutions. throughput as well.
Other types of calibration software from
Fluke Calibration include data-logging software, Documentation and reports—Calibration auto-
software that generates calibration constants mation software typically includes features for
and references, and various add-on and plug-in documenting calibration procedures, storing cali-
software programs. bration data, and producing reports, allowing users
to eliminate paper records or spreadsheets.
Why use calibration software?
Because Fluke Calibration software does such a
Using software to automate all or part of the good job of keeping accurate records of all parts of
calibration process offers several important the calibration process, it also supports compliance
advantages. with a wide variety of quality standards.
Consistency—Software automation ensures that
calibrations can be performed exactly the same
way by multiple operators in multiple locations.
This improves the quality of results, reduces errors
and standardizes methods.
MET/TEAM® software is a powerful, flexible, and MET/CAL Plus software automates the calibration
scalable calibration management software solution process to help you manage your workload more
for managing your calibration assets. Designed by efficiently and consistently. The MET/CAL suite
metrologists for metrology, it is ideal for calibra- of applications includes MET/CAL software, the
tion professionals who need to manage workflow industry leader for automated calibration; plus
through the calibration laboratory. MET/TEAM software for asset management.
• Browser-based software enables access that is MET/CAL Plus software provides you with the
convenient, yet secure tools you need to:
• Fully featured for tracking and managing assets • Perform automated calibration on all kinds of
• Fully integrated with the Run Time function of test and measurement tools and equipment,
industry leading MET/CAL® software including dc/lf, RF and microwave instruments
• Replaces MET/TRACK as the recommended data- • Create, edit, test, and document calibration
base engine for MET/CAL software procedures, quickly and easily
• Popular Microsoft SQL server database for reli- • Configure and report a wider range of mea-
able, affordable, non-proprietary data storage surement uncertainty parameters and include
• Workflow management verification data to provide an audit trail and
• Highly customizable fields and labels support further analysis
• Shortcuts (quick links) for easy navigation • Track asset information including calibration
• Promotes quality processes to support and maintenance history and status, traceability,
accreditation users, customers, and location
• Customizable reports with Crystal Reports • Analyze and report asset information; produce
Professional customized printed certificates and reports.
• Automated email alerts and recall escalation • Make data available to other corporate systems
• Mobile module for on-site calibration • Import asset and calibration data into
• Customer web portal to allow read-only access MET/CAL Plus software
for remote customers • Help meet the requirements of quality standards
• Commerce module for quoting, billing, and like ISO 9000, ISO/IEC 17025, NRC 10 CFR, ANSI
contract pricing Z540.3, and others
• Designed for metrology by metrologists
• Backed by Fluke Calibration, expert in calibra-
tion instrumentation and software
• Collect and store manual calibration data
MET/CAL®
Electrical/RF
calibration
software
MET/CAL®
5080A/CAL
The complete solution for auto-
mating calibration processes plus
managing and reporting mea-
surement assets. MET/SUPPORT
• Perform fast, repeatable, and
powerful calibration Software support
• Full storage of calibration data programs
• Rich reporting capabilities
• Configure and report a wider MET/SUPPORTSM Gold
range of measurement uncer- Annual support programs for
tainty parameters MET/TEAM
MET/CAL and MET/TEAM soft-
Warranted Procedures for Calibration asset ware. These premier support
services help you maximize your
MET/CAL® management software investment.
Fully tested, ready-to-go proce- software • Premium support and services
dures designed to satisfy your to help you maximize produc-
needs. MET/TEAM Test Equipment tivity with MET/CAL and
• Optional calibration procedures Asset Management Software MET/TEAM software
for MET/CAL ® Plus Calibration Manage more workload with less • Access to warranted procedure
Software work with MET/TEAM software. library
• Warranted by Fluke Calibration • Browser-based calibration • Prioritized technical support
to produce valid calibrations asset management software • Software updates and upgrades
on the intended unit under test • Fully integrated with MET/CAL® • Priority web content
(UUT) for the specified model Software • Discounts on a variety of
and revision level • Microsoft SQL Server database services
• These procedures automate • Highly customizable
the calibration process under • Email automation Software Training
MET/CAL control • On-site calibration and Services
• Work flow management A range of services to help you
5080A/CAL • Pricing/billing/invoicing maximize your investment in
Easy-to-use standalone software • Customer web portal calibration software.
for the 5080A Multi-Product • Installation and training • MET/TEAM software installa-
Calibrator. services tion and startup
• Quickly calibrate a wide range • MET/TEAM data migration and
of analog and digital workload import
• Provides automated control • Classroom or onsite training
of the calibrator; technician classes:
simply enters readings from – MET/CAL procedure writing
the item being calibrated – Advanced procedure writing
• Easy-to-use procedure – M ET/TEAM Asset
designer; simply select the Management
type of signal needed to per- – Crystal Reports Writing
form a test from a drop-down • Custom MET/CAL procedures
menu, enter the test level and • MET/TEAM self-validation
set the test limits • Custom software services
www.flukecal.com Calibration Software 41
9938 MET/TEMP II Temperature LogWare
Calibration Software v5
9938 MET/TEMP II
Temperature Calibration LogWare
Software v5 Turn a Fluke Calibration
New version of the proven solu- single-channel handheld or
tion for automated temperature 1502A/1504 readout into a real-
calibration time data logger. LogWare II
• Compatible with Windows 7 • Collects real-time data
and 8 operating systems • Calculates statistics and dis-
• Adds support for 9190A Field plays customizable graphs
Metrology Well and 9118A • Allows user-selected start
Thermocouple Furnace times, stop times and sample
• Calibrate PRTs, SPRTs, therm- intervals
istors, thermocouples, and
even liquid-in-glass (LIGs), LogWare II
bi-metallic thermometers, and Turn any Fluke Calibration
connected sensors that can’t multi-channel thermometer read-
be attached to a readout out into a real-time data logger.
• Supports multiple temperature • Collects real-time data using LogWare III
sources and reference probes Fluke Calibration multi-chan-
in the same test for faster nel readouts
calibration and extended test • Calculates statistics and dis-
range plays customizable graphs
• Allows user-selected start
TQSoft and TQAero Thermal times, stop times and sample
Validation Software intervals
For FDA 21 CFR Part 11 and AMS
2750 Compliant Data Collection LogWare III
• Support for Fluke 2638A and Remotely monitor and log a
1586A, for enhanced data virtually unlimited number of
collection and reporting in concurrent log sessions into a
regulated industries central data repository.
• Easy menu system and toolbar • Up to two temperature and
• Test equipment preparation two humidity inputs for each
and sensor calibration DewK
• Data security, audit trail, and • Customize your graph trace
compliance reports color, alarms, and statistics as
you go
2638A Hydra Series III Data Fluke DAQ 6.0 Application Software
Acquisition System
A powerful and versatile application
A price performance breakthrough in for quick and easy configuration,
standalone data acquisition system data logging and analysis using
The Fluke Hydra Series III continues the Hydra Fluke data acquisition products
Series legacy in data acquisition. This new Hydra Fluke DAQ is praised by users for its versatile
Series improves on the long standing, industry handling of data acquisition and logging. Improved
leading specification of best-in-class thermocouple trending, file handling, added web interface, web
accuracy. With basic dc measurement accuracy control, convenient print functions for charts and
of 0.0024 %, 0.5 °C thermocouple accuracy, color graphs and multiple language improvements make
trend display, easy-to-use menu system and world- Fluke DAQ version 6 a feature-rich application that
class industrial safety ratings, the 2638A is a truly you can trust with your important data and analy-
industrial grade, precision data acquisition system. sis needs.
Expandable from 22 to 66 channels of analog
differential measurement, the Hydra 2638A offers Fluke DAQ features easy multi-unit
the flexibility of our Universal Input Connector, configuration, data logging and analysis
which allows quick connect and disconnect of any for any of these products:
type of input to any channel. AC and dc voltage, • 2638A Hydra Series III Data Acquisition
resistance, thermocouple, RTD, thermistor, fre- System/Digital Multimeter
quency and dc and ac current are all selectable • 1586A Super-DAQ Precision Temperature Scanner
inputs for the 2638A. If your measurement need is • 2640A and 2645A NetDAQ® Networked Data
from under twenty channels to over sixty-six chan-
Acquisition Units
nels per unit or thousands of channels per system,
• 2680 Series Data Acquisition Systems
we have you covered.
• DC accuracy of 0.0024 %
• Best-in-class thermocouple accuracy of 0.5 °C
• Up to 67 universal differential, isolated inputs
• On-screen color trend graphing
• Easy menu system for setup and data
management
• Multi-channel real-time data display
• 6.5 digit DMM function selections
• Monitor function for real-time viewing and chart-
ing between scans
• 20 on-board separate math channels
• 45 channels/sec basic dc scan rate
• Internal 75,000 scan memory plus USB drive port
• Data security features
• CAT II 300 V input safety rated