1 Turn inhibit landing calls ON Ensure that the car, car roof and the shaft are empty and secured. 2 Turn the test switch on the side of the The rope gripper should activate to clamp the pumping unit OFF (all models). ropes. Alternatively turn the control panel main switch OFF (all models except 618). 3 Turn the test switch or the control panel The pump unit should operate and open the main switch ON. brake enabling normal operation of the elevator. With model 618 move the valve lever up and turn the test switch OFF. Open the jaws with hand pump. After reaching open position turn the test switch ON and move the valve lever down.
10.2 Overspeed test for ascending car
Step Action Illustration/Note
1 Drive the empty car to the lowest floor. 2 Turn inhibit landing calls ON. 3 With an empty car, overspeed the car Ensure that the car, car roof and the shaft are upwards while keeping the machine brake empty and secured. open. The overspeed governor switch will activate NOTE! Be prepared to stop the car by using the rope gripper. At least the rope gripper reduces the car speed to the speed for which the machine brake, if the rope the buffer is designed. gripper does not operate. 4 If it is impractical to overspeed the car, drive The rope gripper will cause the car to slow the car upwards at nominal speed with the down and stop. machine brake held open. Trip the overspeed governor switch manually. 5 Return the overspeed governor switch back The closed safety circuit activates the to its original position to close the safety hydraulic pump which reloads the brake. circuit. With model 618 move the valve lever up. Turn the test switch OFF. Open the jaws with hand pump. After reaching open position turn the test switch ON. Move the valve lever down.
David Freemantle - What Customers Like About You - Adding Emotional Value For Service Excellence and Competitive Advantage-Nicholas Brealey Publishing (1999)