Model UT81A/B
OPERATING MANUAL
Model UT81A/B: OPERATING MANUAL
Table of Contents
Chapter Title Page
1 Before You Start 6
Overview 6
Unpacking Inspection 7
Safety Information 8
Rules For Safe Operation 8
International Electrical Symbols 10
2 Using The Testing Tool 11
Reading the screen 11
The Meter Structure 12
Functional Buttons 13
3 Making Measurements 15
A. Scope Mode 15
i. Setting up the Sleep Mode, Contrast, Beep 15
ii. ACV, DCV, Hz, ACV and DCA Range 17
iii. Trigger function 19
iv. Waveform data save and recall 19
B. Digital Multimeter Mode 20
i. Measuring Voltages 20
ii. Measuring Currents 22
iii. Measuring Resistance 27
iv. Testing Diodes 29
v. Testing for Continuity 31
vi. Measuring Frequency / Duty Cycle 33
1
Model UT81A/B: OPERATING MANUAL
Table of Contents
Chapter Title Page
vii. Measuring Capacitance 35
4 Using Software 37
5 Maintenance The Test Tool 38
A. General Service 38
B. Replacing the Fuses 39
C. Replacing the Battery 40
6 Specifications 41
Safety and Compliances 41
Physical Specifications 42
General Specifications (Digital Multimeter) 43
General Specifications (Scope) 43
Feature Summary 44
Basic Specifications (Digital Multimeter) 44
Basic Specifications (Scope) 45
Detailed Accuracy Specifications 45
A. DC Voltage 46
B. AC Voltage 46
C. DC Current 47
D. AC Current 48
E. Resistance 49
F. Diode Test 49
G. Continuity Test 50
2
Model UT81A/B: OPERATING MANUAL
Table of Contents
Chapter Title Page
H. Frequency and Duty Cycle % 50
I. Capacitance 51
3
Model UT81A/B: OPERATING MANUAL
List of Tables
Table Title Page
1-1 Unpacking Inspection 7
1-2 International Electrical Symbols 10
2-1 Reading the Screen 11
2-2 Functional Buttons 13
4
Model UT81A/B: OPERATING MANUAL
List of Tables
Figure Title Page
2-1 Meter Structure 12
2-2 Functional Buttons 13
3-1 Waveform Display 17
3-2 Voltages Measurement 21
3-3 µA Range Measurement 23
3-4 mA Range Measurement 24
3-5 10A Range Measurement 25
3-6 Resistance Measurement 27
3-7 Diode Test 29
3-8 Continuity Test 31
3-9 Frequency / Duty Cycle Measurement 33
3-10 Capacitance Measurement 35
5-1 Fuse Replacement 39
5-2 Battery Replacement 40
5
Model UT81A/B: OPERATING MANUAL
Chapter 1
Before You Start
Overview bandwidth UT81A:2MHz,UT81B:8MHz, real-time sample
This Operating Manual covers information on safety rate 40MS/s with peak rate sampling process can catch
and cautions. Please read the relevant information up pulse industrial signal. It can measure AC/DC engine,
carefully and observe all the Warnings and Notes transducer, circuit, control, UPS and industrial
strictly. equipments. It is an ideal tools in professional repairing
industries.
Warning
To avoid electric shock or personal injury, read the
“Safety Information” and “Rules for Safe Operation” Digital Multimeter mode can measure AC voltage and
carefully before using the Meter. current, DC voltage and current, Resistance,
Capacitance, Frequency, Duty Cycle, Diodes and
Scope Digital Multimeter UT81A/B (hereafter referred Continuity.
to as “the Meter”) is a 3999 counts and 3 3/4 digits
adopting digital control techique with both waveform
and multimeter all in one.
6
Model UT81A/B: OPERATING MANUAL
Unpacking Inspection
Open the package case and take out the Meter. Check the items shown on Table 1-1 carefully to see any missing
or damaged part:
Table 1-1. Unpacking Inspection
In the event you find any missing or damage, please contact your dealer immediately.
7
Model UT81A/B: OPERATING MANUAL
8
Model UT81A/B: OPERATING MANUAL
AC or DC
DC Measurement
AC Measurement
Continuity Test
Diode
Grounding
Double Insulated
Warning. Refer to the Operating Manual
Deficiency of Built-In Battery
Conforms to Standards of European Union
10
Model UT81A/B: OPERATING MANUAL
Chapter 2
Using the Testing Tool
Reading the Screen
The screen displays the menu that provides the following
choices available: Table 2-1. Reading the Screen
Table 2-1. Reading the Screen
Display Description
Display Description RANG Decrease a range
Contrast The degree of contrast BASE Increase a time base
Auto Off Sleep mode time BASE Decrease a time base
BK Light Display backlight BASE > Waveform moves right
BEEP Beeper on and off BASE < Waveform moves left
ENTER Confirm TRIG Trigger moves up
Increase TRIG Trigger moves down
Decrease SLOP Trigger slope adjustment
MOVE Waveform moves up AUTO Auto trigger mode
MOVE Waveform moves down NORM Normal trigger mode
RANG Increase a range SHOT Single trigger mode
11
Model UT81A/B: OPERATING MANUAL
1. USB Terminals
2. LCD Display
3. Functional Buttons
4. Rotary Switch
5. Power adaptor Input Terminals
6. 10A Input Terminal
7. mAµA Input Terminals
8. COM Input Terminal
9. Other Input Terminals
12
Model UT81A/B: OPERATING MANUAL
13
Model UT81A/B: OPERATING MANUAL
Buttons Description
Mode To switch between waveform display
(scope mode) and digital reading
(multimeter mode). This button is only
valid when under voltage, frequency,
currents mode.
Set Press Set button to set the auto power
off, backlight, contrast and beep
Save/Call Under scope mode, press Save/Cal to
store and recall data.
Hold Press Hold button to enter or exit hold
mode.
14
Model UT81A/B: OPERATING MANUAL
Chapter 3
Making Measurement
Introduction
Chapter 3 explains how to make measurements.
Based on the working environment to set up sleep
You could turn the Meter off by turning to OFF position mode, contrast, beep
or set up the sleep mode from 1-30 minutes. Please Press Set button to set the auto power off, display
must ensure the Meter is not under sleep mode if you backlight, contrast and beep
turn the Meter on but without display. Auto off Bk Light Contrast Beep
F1 F2 F3 F4
To avoid false readings, which could lead to possible
electric shock or personal injury, replace the battery as
F1: Set auto power off time
soon as the battery indicator “ ” appears.
Auto off 15 ENTER
F1 F2 F3 F4
The time level is from OFF, 1 to 30 minutes. Press F4
to confirm, save and return. Press functional button to
exit and the setting remains unchanged.
15
Model UT81A/B: OPERATING MANUAL
F2: Set the Display Backlight F4: Set the beeps features, it can only be used under
BK Light 15 ENTER resistance, diode and continuity measurement.
F1 F2 F3 F4 Beep ON OFF ENTER
The brightness level from 0 to 31. Press F4 to F1 F2 F3 F4
confirm, save and return. Press functional buttons
to exit, the setting is kept, but will not save. The F2 : to turn the beep on
setting will be lost after power off. F3 : to turn the beep off
F4 : to confirm , save and return
F3: Set the LCD contrast
Contrast 15 ENTER Press functional buttons to exit, the setting is kept, but
F1 F2 F3 F4 will not save. The setting will be lost after power off.
The contrast level from 0 to 31. Press F4 to confirm,
save and return. Press functional buttons to exit,
the setting is kept, but will not save. The setting will
be lost after power off.
16
Model UT81A/B: OPERATING MANUAL
17
Model UT81A/B: OPERATING MANUAL
Y-axis adjustment: Press Range button under scope F1: increase the number of periods
mode, the corresponding functional button: F2: decrease the number of periods.
Move Move Rang Rang F3: trigger point move left
F1 F2 F3 F4 F4: trigger point right move
F1: move up the waveform The auto set feature will be off when changing the
F2: move down the waveform measurement mode.
F3: go up range
F4: go down a range
18
Model UT81A/B: OPERATING MANUAL
10 location)
Press Trig button under scope mode, the F4: confirm
corresponding function buttons: When saving the data, it will overwrite the current
Trig Trig Auto/Norm/Shot Slop Rrise/Fall data in the location no matter that location has data
F1 F2 F3 F4 or not.
If you recall the location has no data, the meter will
appear error message, you need to press HOLD
F1: move the trigger level up
button to continue measurement,
F2: move the trigger level down If you recall the location has data, it will save the
F3: select the trigger mode: auto, normal or single current setting and display the data, the LCD top left
F4: slope adjustment: rise or fall shows REV to indicate recalling mode is on. Press
HOLD button to return to working mode and continue
measurement. You could continue recalling under
iv. Waveform data save and recall
recall mode or save the data.
Press Save/Call button under scope mode, the Recall mode can be used under any scope mode.
corresponding functional buttons: For example, it is possible to recall the waveform or
Save/Call 1 Enter data saved from voltage or frequency mode when
F1 F2 F3 F4 the meter is under current measurement mode.
Recall mode can be worked under any waveform
mode. For example: the Meter is at current mode
F1: save or recall
but recalling the waveform or data which are saved
F2 and F3: select location (location from 0-9, total under voltage or frequency mode. The Meter must
19
Model UT81A/B: OPERATING MANUAL
20
Model UT81A/B: OPERATING MANUAL
Note:
After changing the measurement mode, the
autoranging will be off automatically and the AUTO
will be disappeared at the bottom left of the LCD.
When voltage measurement has been completed,
disconnect the connection between the testing
leads and the circuit under test and remove testing
leads away from the input terminals of the Meter.
Figure 3-2. Voltages Measurement
21
Model UT81A/B: OPERATING MANUAL
Warning
If the fuse burns out during measurement, the Meter
may be damaged or the operator himself may be
hurt.
22
Model UT81A/B: OPERATING MANUAL
1. Insert the red test lead into the µmA terminal and
To measure ACµA or DCµA currents, set up the black test lead into the COM terminal.
Meter as Figure 3-3 and proceed as follows: 2. Set the rotary switch to µA .
3. Connect the test lead in series with the return circuit
to be tested.
4. The measured value shows on the display.
5. Press MODE button to toggle between Multimeter
mode and Scope mode.
6. Press F1 to toggle between AC and DC current
measurement.
23
Model UT81A/B: OPERATING MANUAL
1. Insert the red test lead into the µAmA terminal and
To measure ACmA or DcmA currents, set up the black test lead into the COM terminal.
Meter as Figure 3-4 and proceed as follows: 2. Set the rotary switch to mA .
3. Connect the test lead in series with the return circuit
to be tested.
4. The measured value shows on the display.
5. Press MODE button to toggle between Multimeter
mode and Scope mode.
6. Press F1 to toggle between AC and DC current
measurement.
24
Model UT81A/B: OPERATING MANUAL
1. Insert the red test lead into the 10A terminal and
To measure AC 10A or DC 10A currents, set up black test lead into the COM terminal.
the Meter as Figure 3-5 and proceed as follows: 2. Set the rotary switch to A .
3. Connect the test lead in series with the return circuit
to be tested.
4. The measured value shows on the display.
5. Press MODE button to toggle between Multimeter
mode and Scope mode.
6. Press F1 to toggle between AC and DC current
measurement.
25
Model UT81A/B: OPERATING MANUAL
26
Model UT81A/B: OPERATING MANUAL
Warning
To avoid possible damages to the Meter or to the
devices under test, disconnect circuit power and
discharge all the high-voltage capacitors before
measuring resistance.
To measure resistance, set up the Meter as shown in
Figure 3-6 and follow the following procedure:
27
Model UT81A/B: OPERATING MANUAL
1. Insert the red test lead into the Ω terminal and the Note
black test lead into the COM terminal.
2. Set the rotary switch to Ω When measuring low resistance, the test leads can
3. Connect the test leads across with the object being add 0.1Ω to 0.2Ω of error to resistance measurement.
measured. To test the leads, touch the probe tips together and
4. The measured value shows on the display. read the resistance of the leads. Take the reading
obtained to subtract the resistance of the leads to
When measuring resistance, the corresponding get the final reading.
functional buttons: For high-resistance measurement (>1MΩ) or low
resistance measurement (<40Ω), it is normal taking
RES REL Rang Rang
several seconds to obtain a stable reading.
F1 F2 F3 F4 The LCD displays “OL” indicating open-circuit without
input.
F1: toggle to diode mode When resistance measurement has been completed,
F2: relative mode disconnect the connection between the testing leads
F3: select to a range up and the circuit under test and remove testing leads
away from the input terminals.
F4: select to a range down
28
Model UT81A/B: OPERATING MANUAL
29
Model UT81A/B: OPERATING MANUAL
1. Insert the red test lead into the Ω terminal and the Note
black test lead into the COM terminal.
Connect the test leads to the proper terminals as
2. Set the rotary switch to Ω .
said above to avoid error display.
3. For forward voltage drop readings on any
The LCD will display OL indicating either open
semiconductor component, place the red test lead
circuit or wrong polarity connection.
on the component’s anode and place the black test
The unit of diode is volt (V), displaying the positive-
lead on the component’s cathode. The red test lead
connection voltage-drop value.
polarity is “+” while the black test lead polarity is “—
When diode testing has been completed, disconnect
“.
the connection between the testing leads and the
The measured value shows on the display.
circuit under test and remove the test leads away
from the input terminals.
When measuring diode, the corresponding functional
buttons:
DIODE REL
F1 F2
F1: toggle to continuity buzzer
F2: relative mode
30
Model UT81A/B: OPERATING MANUAL
31
Model UT81A/B: OPERATING MANUAL
1. Insert the red test lead into the W terminal and the Note
black test lead into the COM terminal.
2. Set the rotary switch to Ω . When continuity testing has been completed,
3. Connect the test leads across with the object being disconnect the connection between the testing leads
tested. and the circuit under test and remove the test leads
4. The tested circuit overload resistance value shows away from the input terminals.
on the display.
5. The beeper comes on continuously for open
conditions, that is test resistance 10W.
6. The beeper does not sound when the test resistance
is 100W
32
Model UT81A/B: OPERATING MANUAL
1. Insert the red test lead into the Hz terminal and the
black test lead into the COM terminal.
Warning 2. Set the rotary switch to Hz.
To avoid harms to you, please do not attempt to 3. Connect the test leads across with the object being
input voltage higher than 42V rms. measured.
To measure frequency and duty cycle, connect the 4. The measured value shows on the display.
Meter as Figure 3-9 and do the following: 5. Press MODE button to toggle between Multimeter
mode and Scope mode.
6. Press F1 to toggle between frequency and duty cycle
measurement.
Note
The requirement of Input amplitude “a” is as follows:
When 1MHz: 300 mV a 30Vrms;
1MHz: 600 mV a 5Vrms
It is normal to have few seconds run time when
switch from other functions to these functions.
When Hz or duty cycle measurement has been
completed, disconnect the connection between the
testing leads and the circuit under test and remove
the test leads away from the input terminals.
34
Model UT81A/B: OPERATING MANUAL
35
Model UT81A/B: OPERATING MANUAL
1. Insert the red test lead into theterminal and the When measuring capacitance, the corresponding
black test lead into the COM terminal. functional buttons:
2. Set the rotary switch to measurement mode, the Capacity REL
Meter may display a fixed reading which is a internal
F1 F2
distributed capacitor value. For testing less than
40nF capacitor, the tested value must subtract the
internal distributed capacitor value to maintain the F2: relative mode
accuracy.
3. To improve the accuracy, press F2 REL with the Note
test leads open to subtract the residual capacitance
of the Meter and the test leads. Capacitors larger than 10 F take longer time.
4. It is recommended to use as short as test lead If the tested capacitor has polarity, connect the red
carrying out measurement to reduce the effect of test lead to positive side and black test lead to
internal distributed capacitor. negative side.
When capacitance measurement has been
completed, disconnect the connection between the
testing leads and the circuit under test and remove
the test leads away from the input terminals of the
Meter.
36
Model UT81A/B: OPERATING MANUAL
Chapter 4
Using Software
When using the Software, please refer to the Installation Guide of the included CD-ROM.
37
Model UT81A/B: OPERATING MANUAL
Chapter 5
Maintaining The Test Tool
This chapter provides basic maintenance information high temperature, explosive, inflammable and strong
including battery and fuse replacement instruction. magnetic field.
Warning
Do not attempt to repair or service your Meter
unless you are qualified to do so and have the
relevant calibration, performance test, and service
information.
A. General Service
l Periodically wipe the case with a damp cloth and
mild detergent. Do not use abrasives or solvents.
l To clean the terminals with cotton bar with detergent,
as dirt or moisture in the terminals can affect
readings.
l Turn the Meter to OFF when it is not in use.
l Take out the battery when it is not using for a long
time.
l Do not use or store the Meter in a place of humidity,
38
Model UT81A/B: OPERATING MANUAL
B. Replacing the Fuses Follow Figure 5-1 and proceed as follows to replace
the Meter’s fuse:
Turn the rotary switch to OFF and remove all
connections from the terminals.
Remove the screw from the battery compartment,
and separate the battery compartment from the case
bottom.
Remove the three screws from the case bottom,
and separate the case bottom from the case top.
Remove the fuse by gently prying one end loose,
then take out the fuse from its bracket.
Install ONLY replacement fuses with the identical
type and specification as follows and make sure the
0.5A/1000V 10A/1000V
fuse is fixed firmly in the bracket.
1.Remove the 2.Remove the 3.Install fuses with Fuse 1: F0.5A/1000V Φ6.35×31.8mm
battery compartment case bottom correct type and
specification Fuse 2: F10A/1000V Φ6.35×32mm
Figure 5-1. Fuse Replacement Rejoin the case bottom and case top, battery
compartment and case bottom, and install the 5
Warning screws.
To avoid electrical shock or arc blast, or personal Replacement of the fuses is seldom required. Burning
injury or damage to the Meter, use specified fuses of a fuse always results from improper operation.
ONLY in accordance with the following procedure.
39
Model UT81A/B: OPERATING MANUAL
40
Model UT81A/B: OPERATING MANUAL
Chapter 6
Specifications
Safety and Compliances
Maximum Voltage between any Terminal and Refer to different range input protection voltage
Grounding
Certification
Compliances IEC 61010 CAT. II 1000V, CAT.III 600V overvoltage
and double insulation standard
Fused Protection for mA input terminal: F0.5A/1000V Φ6.35×31.8mm
Fused Protection for 10A input terminal: F10A/1000V Φ6.35×32mm
41
Model UT81A/B: OPERATING MANUAL
Physical Specifications
Display (LCD) Digital: 3999 counts on display ; updates 2-3 times / second.
o o o o
Operating Temperature 0 C~40 C (32 F~104 F)
o o o o
Storage Temperature -10 C~50 C (14 F~122 F)
o o
Relative Humidity 75% @ 0 C~40 C;
o o
0% @ -10 C~50 C.
Altitude Operating: 2000m;
Storage: 10000m.
Battery Type 1.5V (R6) x 4 Batteries or Power adaptor. Check carefully about the
working voltage of power adaptor before use.
Electromagnetic Compatibility l In a radio field of 1 V/m below:
Overall Accuracy = Specified Accuracy + 5% of Range
l In a radio field of 1 V/m above:
No assigned accuracy is specified.
Dimensions (H x W x L) 200 x 100 x 48mm.
Weight Approx. 498g (including battery)
42
Model UT81A/B: OPERATING MANUAL
43
Model UT81A/B: OPERATING MANUAL
Feature Summary
Display 160 x 160 Monochrome
Autorange When it is under multimeter mode, the Meter automatically selects
best range
Continuity Beeper sounds for resistance readings below threshold.
Duty Cycle Measure signal on or off time in %.
Battery Access Door Battery replaceable.
44
Model UT81A/B: OPERATING MANUAL
45
Model UT81A/B: OPERATING MANUAL
A. DC Voltage
Range Resolution Accuracy Overload Protection Input Impedance
400mV 100µV
4V 1mV Around 10MΩ
40V 10mV (0.8%+8) 1000V DC or AC (excluding waveform)
400V 100mV
1000V 1V (0.1%+8)
B. AC Voltage
46
Model UT81A/B: OPERATING MANUAL
C. DC Current
Range Resolution Accuracy Overload Protection
400µA 0.1µA
4000µA 1 µA (1%+8) F0.5A/1000V Φ6.35×31.8mm
40mA 10µA
400mA 100µA (1.2%+8)
4A 1mA F10A/1000V Φ6.35×32mm
(1.5%+8) (Continuous measurement 10 seconds
10A 10mA
and interval more than 15 minutes.)
47
Model UT81A/B: OPERATING MANUAL
D. AC Current
48
Model UT81A/B: OPERATING MANUAL
E. Resistance
Range Resolution Accuracy Overload Protection
400Ω 0.1Ω (1.2%+5)
4kΩ 1Ω
40kΩ 10Ω (1%+5)
1000VDC or AC rms
400kΩ 100Ω
4MΩ 1kΩ (1.2%+5)
40MΩ 10kΩ (1.5%+5)
F. Diode Test
Range Resolution Overload Protection Remarks
49
Model UT81A/B: OPERATING MANUAL
50
Model UT81A/B: OPERATING MANUAL
I. Capacitance
51
Model UT81A/B: OPERATING MANUAL
** END **
52
Model UT81A/B: OPERATING MANUAL
53