Vous êtes sur la page 1sur 1

MALLA PPAL 16 VAR # 4 + VAR # 4 @ 0.

11 MTS C/U CONCRETO


G F E D C B A MALLA SECC 12 VAR # 4 + VAR # 4 @ 0.16 MTS C/U 3000 PSI PROYECCION DE PARED EXISTENTE

0.10

PROYECCION DE PARED EXISTENTE


0.08
ANCLAJE

PROYECTO:
VC-1 C-1
0.11
VC-1 0.50
0.11
VC-1 VC-1 VC-1
VC-1
VC-1
MAMP REF #3 @ 0.40 A/D 2.20 MAMP REF #3 @ 0.40 A/D MAMP REF #3 @ 0.40 A/D VC-1
1.81 VM-1

5.63
1.85
BODEGA
VC-1 VC-1 VC-1 VC-1 VC-1 VC-1
3.50
0.50
PD-1 ANCLAJE MERCADO
2.20 2.20 C-1
0.11
0.11
ORIENTAL
MAMP REF #3 @ 0.40 A/D MAMP REF #3 @ 0.40 A/D MAMP REF #3 @ 0.40 A/D 0.40

C-1 C-1 C-1 C-1 C-1 C-1


0.08 Zc-1 CONCRETO
VE-1 VE-1 VE-1 VE-1 VE-1 VE-1 3000 PSI
MEJORAMIENTO: CON MATERIAL EXTRAIDO MEZCLAR HOMOGENEAMENTE EN
1.60 1.60 PROPORCION 30% Y 70% DE MATERIAL DE PRESTAMO SELECCIONADO, SIN
PLASTICIDAD ,SE DEBERA HACER CON CEMENTO PORTLAND Y COLOCAR EN
0.30 0.20
CAPAS HASTA NIVEL DE ZAPATAS, CON ESPESORES MAXIMOS 20 CM,
COMPACTADO 95% PRUEBA ASTM D 558, 2.5 SACOS DE CEMENTO POR METRO
CUBICO DE MATERIAL SECO SUELTO REFF PPAL VAR # 4 @ 0.20 MTS
4.70 VC-1 VC-1 VC-1 VC-1 VC-1 VC-1 4.70 SOBRE ANCHO DE 0.30 MTS AMBOS LADOS REFF SECC 5 VAR # 4

MAMP REF #3 @ 0.40 A/D


2.50
MAMP REF #3 @ 0.40 A/D
2.50
MAMP REF #3 @ 0.40 A/D DETALLE DE UNION 0.08
Zc-3

0.08 PROPIETARIO:
C-1 C-1
NPT = 0+00 M
C-1 C-1 C-1 NPT = 0+00 M C-1 C-2 C-1 / PD-1 / Zc-1 / Zc-3 0.30 1.00 0.10
NIVEL ACERA 0.20
0.20 VA-1 0.20 VA-1 0.20 VA-1 0.20 VA-1 0.20 VA-1 0.20 VA-1
0.20 NIVEL ACERA
ESC 1:20 ZORAYDA LOPEZ
1.50 0.90 0.90 1.50

0.30 Zc-3 Zc-3 Zc-3 Zc-3 Zc-3 Zc-3 0.30 0.40


0.40 0.40 C-1

MEJORAMIENTO INDICADO EN PLANOS MEJORAMIENTO INDICADO EN PLANOS MEJORAMIENTO INDICADO EN PLANOS

NPT = 0+00 M

ELEVACION ESTRUCTURAL EJE 1 NIVEL DE ACERA


0.20 PROYECCION
SUELO
0.30

ESC 1:75 0.03


LOCALIZACION:
0.20
0.30
0.05 0.05 0.10 0.10 VA-1 0.08 MANAGUA, NICARAGUA
G F E D C B A
PROYECCION 0.30 REF. LONG 4 VAR #4 ESTRIBOS #2,
SUELO
5 PRIMEROS @ 0.05 mts,
RESTO @ 0.10 mts C/U
0.10
CONCRETO REF. LONG 8 VAR #5 0.80
1.50 DOBLE ESTRIBOS #3 @ 0.10 mts C/U
3000 PSI
0.30
VC-1
0.10
MALLA PPAL 16 VAR # 4 + VAR # 4 @ 0.11 MTS C/U
CONTENIDO:
VC-1 MALLA SECC 12 VAR # 4 + VAR # 4 @ 0.16 MTS C/U
VC-1 0.10 0.10
VC-1 0.08 0.08 CUADRO DE SECCIONES
VC-1
0.40
0.16 0.16
0.40
DETALLE DE ZAPATAS
VC-1 0.50
0.11 0.11
ELEVACIONES ESTRUCTURALES
0.08 Zc-1 0.08
5.62 0.08
MEJORAMIENTO: CON MATERIAL EXTRAIDO MEZCLAR HOMOGENEAMENTE EN PROPORCION
DETALLES ESTRUCTURALES
4.88 30% Y 70% DE MATERIAL DE PRESTAMO SELECCIONADO, SIN PLASTICIDAD ,SE DEBERA
0.40 HACER CON CEMENTO PORTLAND Y COLOCAR EN CAPAS HASTA NIVEL DE ZAPATAS, CON 0.40
3.89 ESPESORES MAXIMOS 20 CM, COMPACTADO 95% PRUEBA ASTM D 558, 2.5 SACOS DE
3.50
CEMENTO POR METRO CUBICO DE MATERIAL SECO SUELTO

C-1

1.00
C-1 C-1 C-1 C-1 C-1 C-1
0.40
VE-1 VE-1 VE-1 VE-1 VE-1 VE-1
SECCION C-1 / VA-1 / Zc-1 Ing. Edgard Rodriguez
ESC 1:20 Lic. MTI. 8552
ESTRUCTURA
4.70 4.10 4.10 4.70

NOTA: EN PAREDES MAYORES A 3 METROS RELLENAR DOS CELDAS CONSECUTIVAS EN MITAD DE CLARO
RELLENAR HUECO CON REFUERZO VERTICAL 38" REFUERZO HORIZONTAL 38" PARED DE MAMPOSTERIA
C-1 C-1 C-1 C-1 C-1 C-1 C-2 CONCRETO 3000 PSI @ 0.40 mts C/U @ 0.40 mts C/U REFORZADA
NPT = 0+00 M
NIVEL ACERA 0.20 0.30 0.30 0.20 NIVEL ACERA
VA-1 0.20 VA-1 0.20 0.20 VA-1 0.20 VA-1 0.20 VA-1 0.20 VA-1 0.08
0.15
1.50 0.80 1.50
1.20
0.40 Zc-1 Zc-1 0.30 Zc-1 0.30 0.30 Zc-1 0.30 0.40 Zc-1 Zc-2 Zc-1 0.40
DESARROLLO 0.40
0.40 0.40
MEJORAMIENTO INDICADO EN PLANOS MEJORAMIENTO INDICADO EN PLANOS MEJORAMIENTO INDICADO EN PLANOS

ELEVACION ESTRUCTURAL EJE 2 1.00 DIBUJO:


ESC 1:75 0.77

0.20 0.20 0.20 0.20 Ing. Stiven Hernandez Nicoya

6"
3
ATIEZADORES 16 "
1
8"
E-6011
PERFORACION PARA PLACA,
VARILLA CON TUERCA ROSCA Y
ATIEZADOR
1
8"
E-6011 REVISO:
3
4"X5"X16 "
ARANDELA VARILLAS 58" CM-1
PD-1 PD-1 VM-4 VME-1 VSEC-1 VES-1 CM-1
0.04 0.04 0.04 0.04 4"
2" NPT=0.00 Zc-1 Ing. Edgard Rodriguez
5" 2" 0.08 CONCRETO 3000 PSI 0.08
0.04 0.04 5" PLACA BASE 6" 5"
4" 8"
3
tf=16 " 14"X14"X12"
4"
1
4"
1
8"
6"
1
14" 6" CM-1 14" 14"
2" 2" REF. SEC 5 VARILLAS #4 REF. PPAL VAR #4
@ 0.20 mts C/U
REF. SEC 5 VARILLAS #4
HOJA No.
8" 8" COLUMNA 2" 4"
3
tw=16 " 5"
1 6"X6"X81"
0.35 0.35 6" 12" 6" 8" 8" 6"
4" PROTECCION PARA CM-1
CONCRETO 3000 PSI
2"

0.35
0.04

0.35
0.04
3
tf=16 "
4" 6"
14"
4" 2" 5"
14"
5" 2"
PD-1

0.35
PD-1
ES-2
ESC: 1:10 ESC: 1:10 ESC: 1:10 ESC: 1:10 ESC: 1:10 ESC: 1:10 ESC: 1:10 DE
REFUERZO LONGITUDINAL 8 No.5 REFUERZO LONGITUDINAL 8 No.5 CAJA METALICA PERFIL I CAJA METALICA CAJA METALICA CAJA METALICA
DETALLE FIJACION PLACA BASE DETALLE DE Zc-3 / MAMP REF
ES-5
REF. TRANS. EST. No. 3 @ 0.075 mts C/U REF. TRANS. EST. No. 3 @ 0.075 mts C/U 4"x6"x81" 3
5"X12" tf=16 3
" tw=16 " 4"x6"x81" @ 0.60 mts C/U 4"x8"x81" 6"x6"x81"

ESC 1:10 ESC 1:10

Vous aimerez peut-être aussi