1 2 3 4 5 6 7 NOTES
* THIS DRAWING SHOULD NOT BE USED FOR EXECUTION
UNLESS IT IS STAMPED AND SIGNED
* THIS DRAWING MUST BE READ ALONG WITH
THE WORKING/ARCHITECTURAL DRAWING
* THIS DRAWING SHOULD NOT BE SCALED OFF
SCHEDULE OF COLUMN 1 2 1 2
1 2 1 2
ONLY WRITTEN DIMENSIONS SHOULD BE FOLLOWED
C17
Sr. No COLUMN NO SIZE STEEL LINKS REMARK
9"x15" 9" X 15" * STEEL FE-500 EXCEPT FOR 6 MM DIA BARS
C16 9" X 18"
C15 1 C1 C2 DIA 1' 6 - # 12 8 # @ 8" C/C - 6 # 12 + * GRADE OF CONCRETE M-20 UNLESS SPECIFIED
9"x15" 9"x18" 4 # 16 + 8 # @ 8" C/C STEEL LAYING SHOULD BE GOT CHECKED BEFORE
2 C3 6"X18" 6 - # 12 8 # @ 8" C/C - + 4 # 12 (ALT FOUR LEGGED)
CONCRETING
8 # @ 8" C/C C4
8 # @ 8" C/C (ALT FOUR LEGGED) * THIS DRAWING IS PROPERTY OF DHIRAJ K PATIL
3 C4 9"X15" 6 - # 12 -
D (ALT FOUR LEGGED) D STRUCTURAL ENGINEER SHALL NOT BE REPRODUCED OR USED
8 # @ 8" C/C
C9 WITHOUT EXPLICIT PERMISSION OF THIS OFFICE
4 - # 16
C14
4 C5 C12 C16 9"X18" -
+ 2 - # 12 (ALT FOUR LEGGED)
9"x15" STRUCTURAL CONSULTANT WILL NOT BE
4 - # 12 8 # @ 8" C/C
5 C6 9"X18" - RESPONSIBLE FOR -
C13 9"x15" + 2 - # 16 (ALT FOUR LEGGED) 1 2 1 2 1 2 1 2
C7 C8 C10 C11 C13 4 - # 16 8 # @ 8" C/C
C12 6 9"X15" - * THE STABILITY OF STRUCTURE IF ANY CHANGES OR
C14 + 2 - # 12 (ALT FOUR LEGGED)
9" X 15" 9" X 15" MODIFICATIONS ARE MADE IN THIS DRAWING WITHOUT
9"x18" 4 - # 16 8 # @ 8" C/C THE WRITTEN CONSENT
7 C9 9"X18" - 4 # 12 + 4 # 16 +
+ 4 - # 12 (ALT FOUR LEGGED) + 2 # 16 + 2 # 12
C11 9"x15" 4 - # 12 8 # @ 8" C/C 8 # @ 8" C/C * DRAWING RELEASED FOR 'APPROVAL' IS USED ON THE
8 C15 C17 9"X15" - 8 # @ 8" C/C (ALT FOUR LEGGED) SITE FOR CONSTRUCTION PURPOSE
+ 2 - # 16 (ALT FOUR LEGGED)
(ALT FOUR LEGGED)
C8
C15 C17 C7 C8 C10 C11 C13 C14 * SAFETY OF ANY ARCHITECTURAL PROJECTION
9"x15" PROVIDED WHICH IS NOT GIVEN IN THIS DRAWING
C10
* QUALITY OF CONCRETE, QUALITY OF MATERIALS USED
C9 9"x15" FOR CONSTRUCTION,POOR WORKMANSHIP,
SCHEDULE OF FOOTING
9"x18" FAULTY CONSTRUCTION PROCEDURE
STEEL 1 2 1 2 2 1 2
Sr. * ANY ACCIDIENT OCCURING DURING CONSTRUCTION OF
No
COLUMN NO SIZE d D PARALLEL TO PARALLEL TO REMARK STRUCTURE
SHORT SPAN LONG SPAN 9" X 18" 9" X 18"
1 C1 C4 3' X 3' - 12" 6 - # 10mm 6 - # 10mm - 4 # 12 +
4 # 16 + * ANY ACCIDIENT DUE TO INSUFFICIENT AND IMPROPER
SHUTTERING AND CENTERING WORK
ENCETRIC + 2 # 16 + 2 # 12

PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT


C7 2 C2 C3 3' X 3'6" - 12" 6 - # 10mm 6 - # 12mm FOOTING 8 # @ 8" C/C
PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT

9"x15" 8 # @ 8" C/C STABILITY OF ADJOINING STRUCTURES


(ALT FOUR LEGGED)
C 3 C5 C9 C12 C16 5'2" X 4'6" 9" 18" 12 - # 10mm 9 - # 10mm - (ALT FOUR LEGGED) C * SETTELMENT OF BED CONCRETE .
C5
C5 C12 C1
C6 ENCETRIC C6 * CRACKS IN WALLS
9"x18" 4 C6 5'2" X 4'6" - 18" 10 - # 10mm 9 - # 12mm
9"x18" FOOTING * CRACKS DUE TO SHRINKAGE OF CONCRETE
ENCETRIC
5 C7 C8 C11 C13 4'6" X 4'2" - 18" 11 - # 10mm 9 - # 12mm FOOTING
C4
9"x15" 6 C10 4'6" X 4'2" 9" 18" 11 - # 10mm 9 - # 10mm -
ENCETRIC
7 C14 C15 C17 4'4" X 4' - 18" 11 - # 10mm 8 - # 12mm FOOTING 1 2 1 2
C3
DIA 1' DIA 1' 6" X 18"
6"x18" C1 DIA 1' 6 # 12 6 # 12
C2 8 # @ 8" C/C 8 # @ 8" C/C
C1 C2 C3
REVISION
REV. DATE DISCRIPTION MADE CHEK. APPR.
PRINTS
DATE ISSUED TO COPIES
B B
GL GL BILL OF QUANTITY
8 # @ 8" C/C
COLUMN STEEL QUANTITY TABLE
SR
COLUMN 8 # @ 8" C/C NO. DIA. OF BAR WEIGHT UNIT
1 8 mm 240.00 KG
2 10 mm 220.00 KG PROJECT
A A D
6" 4 12 mm 320.00 KG Proposed Residential Bunglow for
3" 5 16 mm 530.00 KG Mr. Netaji Gurav at Gokul Shirgaon ,Kolhapur
THK PCC
3" THK. 7 M20 21.90 CUM
P.C.C. DRAWING CONTENT
TYPICAL SECTION OF ECCETRIC FOOTING
PLAN SCHEDULE OF COLUMN & FOOTING
SECTION A A
TYPICAL SECTION OF FOOTNG DESIGN DHIRAJ DATE 07/03/2018
SCALE NTS
DRN BY DHIRAJ CHK.BY. DHIRAJ
RELEASED FOR APPROVAL
# LOADING CONSIDERED IS G+2 FLOOR. # WALL LOAD CONSIDERED ARE 6"mm & 9"mmTHK BRICK MASONARY. # LIVE LOAD CONSIDERED AS 2 kN/Sq m
ARCHITECT:
A I. USE M20 GRADE CONCRETE CONFIRMING I. S. CODE 456 IX. DESHUTTERING PEROID XI. AT MID SPAN OF SUPPORTED BEAMS HAVING SPAN 21'0" ABOVE. A
II. USE Fe 500 GRADE STEEL CONFIRMING I.S. CODE 1786 EXCEPT a) VERTICAL FORMWORK TO COLUMN, WALL AND BEAM S = 16 - 24 HRS XII. THE CARE SHALL BE TAKEN BY THE CONTRACTOR WHILE WORKING ON SITE
6MM SHALL BE FE250 GRADE b) SOFFIT FORMWORK TO SLAB HAVING ABUTTING ADJUCENT BUILDINGS, WE ARE NOT RESPONSIBLE FOR ANY
III. CENTERING DESIGN IS CONTRACTORS RESPONSIBILITY. (PROPS TO BE REFIXED IMMEDIATE AFTER REMOVED OF FORMWORK.) = 3 DAYS DAMAGE IF CAUSED TO ABUTTING BUILDINGS.
IV. CLEAR COVERS TO FOOTING = 2" , COLUMN = 1 43" , BEAM = 1" , c) SOFFIT FORMWORK TO BEAMS XIV.FOR CANTILIVER BEAMS, TOP REINFORCEMENT SHOULD BE ANCHORED BEHIND
(PROPS TO BE REFIXED IMMEDIATE AFTER REMOVED OF FORMWORK) = 7 DAYS FOR 7OXDIA OF BAR OR 1.5 X SPAN OF CANTILIVER WHICH EVER IS GREATER.
SLAB = 43" ,LINTELS = 43"
d) PROPS TO SLAB XV. STRATA SHOULD BE GOT APPROVED BY STR. ENGG. BEFORE CASTING OF CONCRETE.
V. FOR BEAMS HAVING DEPTH MORE THAN 30" PROVIDE SIDE FACE XVI.STEEL SHOULD BE GOT CHEKED BY STR. ENGG. BEFORE CASTING CONCRETE
i) SPANNING UPTO 15'0" = 7 DAYS
REINFORCEMENT 8 # @ 12" C/C ON BOTH FACES. XVII.ANY DISCREPANCY BETWEEN THIS DRG/ARCH DRG/SITE CONDITION
ii) SPANNING OVER 15'0" = 14DAYS
VI. LAPS TO COLUMN BAR = 45 X D. LAPS TO SLAB / BEAM = 69 X D. SHOULD BE BROUGHT TO OUR NOTICE BEFORE EXECUTION.
e) PROPS TO BEAM AND ARCH
VII. FOR BEAMS HAVING WIDTH 6" OR LESS ONLY TWO
i) SPANNING UPTO 18'0" = 14 DAYS ( # - TOR SIGN, ST- STRAIGHT BAR, BT- BENT BAR.) STRUCTURAL DESIGNER:
BARS TO BE PROVIDED IN ANY ONE LAYER.
ii) SPANNING OVER 18'0" = 21 DAYS XVIII.(TYP) 12 # 16 READ AS NO. BARS # BAR DIA.
VIII. FOR BEAMS HAVING WIDTH 9" ONLY THREE
NOTE- THE NUMBER OF PROPS LEFT UNDER,THEIR SIZES & DISPOSITION SHALL BE XIX. AT DISCONTINOUS EDGE OF THE SLAB PROVIDE 8# e 12" C/C AS AN EXTRA TOP DHIRAJ K. PATIL
BARS TO BE PROVIDED IN ANY ONE LAYER. BE (Civil) M.TECH(CIVIL STRUCTURE)
SUCH AS TO BE ABLE TO SAFELY CARRY THE FULL DEAD LOAD OF THE SLAB,BEAM REINFORCEMENT TO THE SLAB.
DRG.NO. STRUCTURAL CONSULTANT
OR ARCH AS THE CASE MAY BE TOGETHER WITH ANY LIVE LOAD LIKELY TO OCCUR XX. ALL LAPS SHOULD BE STAGGERED & NOT MORE THAN 50%. BAR TO BE LAPPED AT AT/PO GOKUL SHIRGAON
DURING CURING OR FURTHER CONSTRUCTION. ANY GIVEN SECTION TAL- KARVEER DST-KOLHAPUR
2018/06/2 X. REFER THIS DRAWING WITH ARCHITECT’S DRAWING. Mo.-9665199215
XXI. S.B.C. CONSIDERED 350 KN/SQM