Fault codes

Signal
Application Fault type Repair recommendation Display message
light

INTARDER ZF - SPN: 4001 - FMI: 05


 Check out valve (80
Ohms < R < 140
Ohms)
Air tank solenoid
 Check out wiring
valve:
between box and
ph0/ph1 WORKSHOP STOP Service
component
Short-circuit to
(continuity and
earth
insulation) (34, 1)
 Check out electronic
box

INTARDER ZF - SPN: 4001 - FMI: 06


 Check out valve (80
Ohms < R < 140
Ohms)
Air tank solenoid  Check out wiring
valve: between box and
ph0/ph1 WORKSHOP STOP Service
component
Short-circuit (continuity and
insulation) (34, 1)
 Check out electronic
box

INTARDER ZF - SPN: 4001 - FMI: 10


 Check out valve (80
Ohms < R < 140
Ohms)
Air tank solenoid  Check out wiring
valve: between box and
ph0/ph1 WORKSHOP STOP Service
component
Open-circuit (continuity and
insulation) (34, 1)
 Check out electronic
box
http://asistencia90.wixsite.com/manuales-camion

INTARDER ZF - SPN: 4008 - FMI: 05


 Check out control
lever
Control lever  Check out wiring
power supply: between box and
CONTROL LEVER
ph0/ph1 component Service
FAULT
Short-circuit to (continuity and
earth insulation) (30)
 Check out electronic
box

INTARDER ZF - SPN: 4008 - FMI: 06


 Check out control
lever
 Check out wiring
Control lever
between box and
power supply: CONTROL LEVER
ph0/ph1 component Service
FAULT
(continuity and
Short-circuit
insulation) (30)
 Check out electronic
box

INTARDER ZF - SPN: 4009 - FMI: 05


 Check out
proportional solenoid ph0:
valve (20 Ohms < R
Proportional < 100 Ohms)
INOPERATIVE
solenoid valve:  Check out wiring
ph0/ph1 between box and Service
ph1:
Short-circuit to component
earth (continuity and
insulation) (4) INTARDER
 Check out electronic
INOPERATIVE
box

INTARDER ZF - SPN: 4009 - FMI: 06


 Check out
proportional solenoid ph0:
valve (20 Ohms < R
Proportional < 100 Ohms) INOPERATIVE
solenoid valve:  Check out wiring
ph0/ph1 Service
between box and ph1:
Short-circuit component
(continuity and INTARDER
insulation) (4) INOPERATIVE
 Check out electronic
http://asistencia90.wixsite.com/manuales-camion

box

INTARDER ZF - SPN: 4009 - FMI: 09


 Check out
proportional solenoid ph0:
valve (20 Ohms < R
Proportional < 100 Ohms)
INOPERATIVE
solenoid valve:  Check out wiring
ph0/ph1 between box and Service
ph1:
resistance value component
incorrect (continuity and
INTARDER
insulation) (4)
INOPERATIVE
 Check out electronic
box

INTARDER ZF - SPN: 4009 - FMI: 10


 Check out
proportional solenoid ph0:
valve (20 Ohms < R
< 100 Ohms)
Proportional INOPERATIVE
 Check out wiring
solenoid valve:
ph0/ph1 between box and Service
ph1:
component
Open-circuit
(continuity and
insulation) (3, 4) INTARDER
 Check out electronic
inoperative
box

INTARDER ZF - SPN: 4010 - FMI: 05


 Check out
proportional solenoid ph0:
valve (20 Ohms < R
Proportional < 100 Ohms)
INOPERATIVE
solenoid valve:  Check out wiring
ph0/ph1 between box and Service
ph1:
Short-circuit to component
earth (continuity and
insulation) (3) INTARDER
 Check out electronic
inoperative
box

INTARDER ZF - SPN: 4010 - FMI: 06


 Check out
proportional solenoid
http://asistencia90.wixsite.com/manuales-camion

valve (20 Ohms < R ph0:


< 100 Ohms)
 Check out wiring
Proportional INOPERATIVE
between box and
solenoid valve:
ph0/ph1 component Service
ph1:
(continuity and
Short-circuit
insulation) (3)
 Check out electronic INTARDER
box inoperative

INTARDER ZF - SPN: 4013 - FMI: 07


 Check out
temperature sensor
(0 < R < 100 kOhms)
Cooling circuit
 Check out wiring
temperature
between box and INTARDER
ph0/ph1 sensor: Service
component POWER LIMITED
(continuity and
Short-circuit
insulation) (9, 37)
 Check out electronic
box

INTARDER ZF - SPN: 4013 - FMI: 10


 Check out
temperature sensor
(0 < R < 100 kOhms)
Cooling circuit
 Check out wiring
temperature
between box and INTARDER
ph0/ph1 sensor: Service
component POWER LIMITED
(continuity and
Open-circuit
insulation) (9, 37)
 Check out electronic
box

INTARDER ZF - SPN: 4014 - FMI: 01


 Check out
proportional solenoid ph0:
valve (20 Ohms < R
< 100 Ohms)
Proportional INOPERATIVE
 Check out wiring
solenoid valve:
ph0/ph1 between box and Service
ph1:
component
Current too high
(continuity and
insulation) (4, 3) INTARDER
 Check out electronic
INOPERATIVE
box
http://asistencia90.wixsite.com/manuales-camion

INTARDER ZF - SPN: 4014 - FMI: 02


 Check out
proportional solenoid ph0:
valve (20 Ohms < R
< 100 Ohms)
Proportional INOPERATIVE
 Check out wiring
solenoid valve:
ph0/ph1 between box and Service
ph1:
component
Current too low
(continuity and
insulation) (4, 3) INTARDER
INOPERATIVE
 Check out electronic
box

INTARDER ZF - SPN: 4015 - FMI: 01


ph0:
 Check voltage at
INOPERATIVE
box terminals (31,
Voltage too high at
ph0/ph1 53) Service
box terminals ph1:
 Check out electronic
box
INTARDER
INOPERATIVE

INTARDER ZF - SPN: 4015 - FMI: 02


ph0:
 Check voltage at
INOPERATIVE
box terminals (31,
Voltage too low at
ph0/ph1 53) (F86/10A) Service
box terminals ph1:
 Check out electronic
box
INTARDER
INOPERATIVE

INTARDER ZF - SPN: 4016 - FMI: 03


 Test the control lever
using Diagnostica
 Check out control
Control lever lever CONTROL LEVER
ph0/ph1 position  Check out wiring Service
FAULT
inconsistent between box and
component
(continuity and
insulation) (15, 16,
http://asistencia90.wixsite.com/manuales-camion

17, 42, 43)


 Check out electronic
box

INTARDER ZF - SPN: 4017 - FMI: 00


 Switch off the
ignition, switch it on
Hour counter again and repeat the
ph0/ph1 operating hours test WORKSHOP STOP Service
error  If the fault persists,
replace the
electronic box

INTARDER ZF - SPN: 4018 - FMI: 00


 Switch off the
ignition, switch it on
again and repeat the
Memory internal
ph0/ph1 test WORKSHOP STOP Service
error
 If the fault persists,
replace the
electronic box

INTARDER ZF - SPN: 4022 - FMI: 00


ph0:
 Switch off the
ignition, switch it on
INOPERATIVE
again and repeat the
ph0/ph1 Internal error test Service
ph1:
 If the fault persists,
replace the
electronic box INTARDER
INOPERATIVE

INTARDER ZF - SPN: 4023 - FMI: 04


 Check out ABS/EBS
box faults
 Check CAN link with
No message
EBS box
ph0/ph1 received from MANUAL MODE Service
 (22, 49): the
ABS/EBS ECU
resistance between
the 2 wires is 60
Ohms
http://asistencia90.wixsite.com/manuales-camion

INTARDER ZF - SPN: 4024 - FMI: 00


 Switch off the
ignition, switch it on
again and repeat the
Buffer memory INTARDER
ph0/ph1 test Service
saturated POWER LIMITED
 If the fault persists,
replace the
electronic box

INTARDER ZF - SPN: 4025 - FMI: 09


 Check out CAN link
 (22, 49): the
CAN bus problem: resistance between
INTARDER
ph0/ph1 the 2 wires is 60 Service
POWER LIMITED
Short-circuit Ohms
 Check out electronic
box

INTARDER ZF - SPN: 4026 - FMI: 04


 Check out ABS/EBS
box faults
 Check out CAN link
No message
with EBS box
ph0/ph1 received from MANUAL MODE Service
 (22, 49): the
ABS/EBS ECU
resistance between
the 2 wires is 60
Ohms

INTARDER ZF - SPN: 4027 - FMI: 00


 Check out CAN link
CAN bus problem:  (22, 49): the
INTARDER
ph0/ph1 resistance between Service
POWER LIMITED
Open-circuit the 2 wires is 60
Ohms

INTARDER ZF - SPN: 4028 - FMI: 04

 Check out EECU box


faults
No message  Check out CAN link
ph0/ph1 received from with EECU box MANUAL MODE Service
EECU EECU
 (terminals 22 and
49 ; wires 0012 and
http://asistencia90.wixsite.com/manuales-camion

0013): the resistance


between the 2 wires
is 60 Ohms

INTARDER ZF - SPN: 4029 - FMI: 04


 Check out
tachograph box
faults
No message  Check out CAN link
ph0/ph1 received from with tachograph MANUAL MODE Service
tachograph ECU  (22, 49): the
resistance between
the 2 wires is 60
Ohms

INTARDER ZF - SPN: 4033 - FMI: 04


 Check out Astronic
and VECU box faults
 If Astronic present,
check out CAN link
No message
with Astronic box
received from INTARDER
ph0/ph1  Check out CAN link Service
Astronic ECU or POWER LIMITED
with VECU box
VECU
 (22, 49): the
resistance between
the 2 wires is 60
Ohms

INTARDER ZF - SPN: 4036 - FMI: 04


 Check out VECU box
faults
 Check out CAN link
No message
with VECU box
ph0/ph1 received from MANUAL MODE Service
 (22, 49): the
VECU
resistance between
the 2 wires is 60
Ohms

INTARDER ZF - SPN: 4037 - FMI: 04


 Check out VECU
box faults
ph0/ph1  Check out CAN link WORKSHOP STOP Service
No message with VECU box
received from  (22, 49): the
http://asistencia90.wixsite.com/manuales-camion

VECU resistance between


the 2 wires is 60
Ohms

INTARDER ZF - SPN: 4047 - FMI: 10


 Check out master
switch
 Check out wiring
between box and
No connection with component
ph0/ph1 WORKSHOP STOP Service
master switch + (continuity and
insulation) (54, 55)
(F28/10A)
 Check out electronic
box