Vous êtes sur la page 1sur 1

Outside Footing

Ø8218
CONCRETE
RING BEAM FOOTING.
Tank Dia. & Rad.
Ø7768
Inside Footing R3884
Ø7318 PRE-FABRICATED
SCOUR DRAIN

1250

1000
DETAIL 2
PLAN - SCOUR FITTING TYPICAL

PRE-FABRICATED
600 SCOUR DRAIN
CONCRETE
Concrete Plinth RING BEAM FOOTING.

ELEVATION - SCOUR FITTING TYPICAL


*CONCRETE FOOTING AS SPECIFIED

RCT-100-22 Smooth Trowel 45'


7.768m Dia. x 2.2m H. Internal Footing Edge Tank Wall Outside
104 kl Total Capacity.
Scale 1 : 50 450 12mm Reo. Top and Bottom.
150mm Clean Sand Fill

150mm Clean Fill. Top Layer. F.G.L.

450
10mm ligitures @ 600cts.

450
F.G.L.
100 kPa Bearing Pressure. 95% MMDD. 300 32 MPA Concrete
Compacted SubGrade
450

Recommend Top of Ring Beam


150mm above finished ground level. DETAIL 1 - FOOTING DETAIL & HOLD DOWN BRACKET
SCALE 1 : 25

CLIENT DRAWN CHECKED REVISION


RHINO WATER TANKS MD DH
02 SUBGRADE NOTES 06/10 PROJECT DATE SCALE
02 INTERNAL TROWEL EDGE
COMMERCIAL WATER STORAGE TANKS 06/11 N.T.S. 03
08/09
01 SCOUR DRAIN FITTED @ CIVIL STD. 04/09 DRAWING TITLE JOB NO. DWG NO.
RCT-100-22. RING BEAM SPECIFICATION. 0000 RCT-RB-100-22
No. REVISION DATE

Vous aimerez peut-être aussi