Vous êtes sur la page 1sur 2

7.

Gigabit Ethernet Interface Modules Rack Mounting


8. Serial Console port
9. 10-pin terminal block for power inputs, and relay output Use four screws to attach the PT switch to a standard rack.
10. Rack Mounting Kit
PowerTrans Switch Dimensions (unit = mm)
PT-7728/7828 Series
Hardware Installation Guide
Third Edition, May 2008

Package Checklist Wiring Requirements


The Moxa PowerTrans switch is shipped with the following items. If any
WARNING
of these items are missing or damaged, please contact your customer
service representative for assistance. Safety First!
Be sure to disconnect the power cord before installing
y 1 Moxa PowerTrans Switch and/or wiring your Moxa PowerTrans Switch.
y Hardware Installation Guide Calculate the maximum possible current in each power
wire and common wire. Observe all electrical codes
y CD-ROM with User’s Manual and SNMP MIB file dictating the maximum current allowable for each wire
y Moxa Product Warranty Statement size.
y RJ45 to DB9 console port cable If the current goes above the maximum ratings, the wiring
could overheat, causing serious damage to your equipment.
y Protective caps for unused ports
y 2 rack-mount ears
Grounding the Moxa PowerTrans Switch
Grounding and wire routing help limit the effects of noise due to
Panel Layouts electromagnetic interference (EMI). Run the ground connection from the
6 7 5 10 ground screw to the grounding surface prior to connecting devices.
1
3 Fast Ethernet Interface Modules (for slots 1, 2, and 3)
STAT
STAT

FAULT
FAULT
PWR1
PWR1

MASTER
MASTER
PWR2
PWR2

COUPLER
COUPLER
22

11

22

11
44

33

44

33
66

55

66

55
88

77

88

77
M1
M1

M2
M2
M1

TX
2

RX TX
4

RX TX
6

RX
M2

TX
2

RX TX
4

RX TX
6

RX
M3 2 4 6 8 M4
2 4 2
PT-7728

96.8 96.8
Wiring the Power Inputs
LNK/ACT
LNK/ACT SPEED
SPEED FDX/HDX
FDX/HDX 22 44 66 88

The PT series of switches supports dual redundant power supplies:


M3
M3 3
11 33 55 77
COUPLER
COUPLER
RING PORT
RING PORT PORT
PORT
MODE
MODE
11 22 33 44 M4
M4
1 3 5 1 3 5 1 3 7 1 3 1
5

2
Front view (Front Cabling) “Power Supply 1 (PWR1)” and “Power Supply 2 (PWR2)”. The

40.7
8

40.7
4
connections for PWR1, PWR2 and the RELAY are located on the
PM-7200-8TX PM-7200-1LSC6TX terminal block. The front view of the terminal block connectors are
PT-7728 shown below.
96.8 96.8 96.8
Rear view (Front Cabling)
9

40.7
40.7

40.7
STAT PWR1 PWR2

FAULT MASTER COUPLER

LNK/ACT SPEED FDX/HDX

PT-7728 MODE RING PORT


COMUPLER
PORT

PM-7200-4MSC2TX/PM-7200-4SSC2TX PM-7200-6MSC/PM-7200-6SSC PM-7200-2MSC4TX/PM-7200-2SSC4TX


Front view (Rear Cabling)
96.8 96.8 96.8
M1 M2 6 7 M3 M4 PT-7728
2 4 6 2 4 6 8 2 4 2
2 4
CONSOLE

TX RX

3
40.7
40.7

40.7
1 3 5 1 3 5 1 3 5 7 1 3 1

Wiring the Relay Contact


Rear view (Rear Cabling)
PM-7200-4MST2TX PM-7200-6MST PM-7200-2MST4TX Each PT switch has one relay output. Refer to the next section for
1. System status LEDs detailed instructions on how to connect the wires to the terminal block
2. Interface Module mode LEDs Gigabit Ethernet Interface Modules (for slot 4) connector, and how to attach the terminal block connector to the terminal
3. Interface Module port LEDs block receptor.
4. Push-button switch to select mode for Interface Module
40.7
40.7

5. Model Name
6. Fast Ethernet Interface Modules 86.6 86.6
P/N: 1802077280012 PM-7200-4GTXSFP PM-7200-2GTXSFP

—1— —2— —3—


This PT switch is the Master of (SFP slot, LC connector)
On this Turbo Ring. System LED STAT, PWR1, PWR2, FAULT, MASTER,
This PT switch has become Ring Indicators COUPLER
MASTER GREEN Blinking Master of this Turbo Ring after the Module LED LNK/ACT, FDX/HDX, SPEED, RING PORT,
Turbo Ring was broken. Indicators COUPLER PORT
This PT switch is not the Master of Alarm Contact One relay output with current carrying capacity of
Off
this Turbo Ring. 3A @ 30 VDC or 3A @ 240 VAC
FAULT: The relay contact of the 10-pin terminal block connector are
used to detect user-configured events. The two wires attached to the When this PT switch enables the Optical Fiber (100BaseFX)
RELAY contacts form an open circuit when a user-configured event is On coupling function to form a Distance Multi-mode
COUPLER GREEN back-up path. 0 to 5 km, 1300 nm (50/125μm, 800 MHz*km)
triggered. If a user-configured event does not occur, the RELAY circuit
will be closed. When this PT switch disables the 0 to 4 km, 1300 nm (62.5/125μm, 500 MHz*km)
Off
coupling function. Single-mode
Wiring the Redundant Power Inputs Mode LEDs 0 to 40 km, 1310 nm (9/125μm, 3.5 PS/(nm*km))
Min. TX Output Multi-mode: -20 dBm; single-mode: -5 dbm
Each PT switch has two On The corresponding module port’s
link is active. Max. TX Output Multi-mode: -10 dBm; single-mode: 0 dbm
sets of power inputs:
power input 1 and power The corresponding module port’s RX Sensitivity Multi-mode: -32 dBm; single-mode: -34 dbm
LNK/ACT GREEN Blinking Power
input 2. data is being transmitted.
The corresponding module port’s Input Voltage 24 VDC (18 to 36V)or 48 VDC (36 to 72V)or
Off 110/220 VDC/VAC
link is inactive.
STEP 1: Insert the dual set positive/negative DC wires into PWR1 and (88 to 300 VDC and 85 to 264 VAC)
The corresponding module port’s
PWR2 terminals (+ → pins 1, 9; - → pins 2, 10). Or insert the L/N AC Off data is being transmitted at 10 Input Current Max. 2.58A @ 24VDC
wires into PWR1 and PWR2 terminals (L → pin 1, 9; N → pin 2,10) Mbps. Max. 1.21A @ 48VDC
Max. 0.64/0.33A @ 110/220VDC
STEP 2: To keep the DC or AC wires from pulling loose, use a The corresponding module port’s
SPEED GREEN On data is being transmitted at 100 Max. 0.53/0.28A @ 110/220VAC
screwdriver to tighten the wire-clamp screws on the front of the terminal Mbps. Physical Characteristics
block connector. Housing IP 30 protection, metal case
The corresponding module port’s
LED Indicators Blinking data is being transmitted at Dimensions
440 x 44 x 325 mm (17.32 x 1.73 x 12.76 in.)
1000 Mbps. (W x H x D)
The front panel of the PT switch contains several LED indicators. The Weight 5900 g
The corresponding module port’s
function of each LED is described in the table below. On data is being transmitted in full Installation 19” rack mounting
duplex mode. Regulatory Approvals
LED Color State Description FDX/HDX GREEN
The corresponding module port’s Safety EN60950-1 (Pending)
System LEDs Off data is being transmitted in half Power Automaton IEC61850-3, IEEE 1613
System has passed self-diagnosis duplex mode.
On Road Traffic NEMA TS2
test on boot-up and is ready to run. The corresponding module’s port
GREEN On Rail Traffic EN50121-4 (Pending)
is the ring port of this PT switch.
STAT Blinking System is undergoing the RING
GREEN Maritime DNV (Pending), GL (Pending)
self-diagnosis test. PORT The corresponding module’s port EMI FCC Part 15, CISPR (EN55022) class A
System failed self-diagnosis on Off is not the ring port of this PT
RED On switch. Environmental Limits
boot-up.
Operating Temp. -40 to 85°C (-40 to 185°F)
Power is being supplied to the The corresponding module’s port
On On is the coupler port of this PT Cold start of min. 100 VAC at -40°C
main module’s power input PWR1.
PWR1 AMBER COUPLER switch. Storage Temp. -40 to 85°C (-40 to 185°F)
Power is not being supplied to the GREEN
Off PORT The corresponding module’s port Ambient Relative
main module’s power input PWR1. 5 to 95% (non-condensing)
Off is not the coupler port of this PT Humidity.
Power is being supplied to the switch. 5 years
On main module’s power input PWR2.
Warranty
PWR2 AMBER
Power is not being supplied to the Specifications Copyright © 2008
Off
main module’s power input PWR2. Technology Moxa Inc.
The corresponding PORT alarm is Standards IEEE 802.3, 802.3u, 802.3ab, 802.3z, 802.3x, All rights reserved.
On enabled and a user-configured 802.1D, 802.1W, 802.1Q, 802.1p, 802.1X, 802.3ad Reproduction without permission is prohibited.
event has been triggered. Flow control IEEE 802.3x flow control, back pressure flow
FAULT RED The corresponding PORT alarm is control
enabled and a user-configured Interface Tel: +886-2-8919-1230 www.moxa.com
Off event has not been triggered, or the Fax: +886-2-8919-1231 support@moxa.com
corresponding PORT alarm is Fast Ethernet 10/100BaseT(X) or 100BaseFX (SC/ST connector)
disabled. Gigabit Ethernet 10/100/1000BaseT(X), 1000BaseSX/LX/LHX/ZX

—4— —5— —6—