Vous êtes sur la page 1sur 12

01

TECO
Since its founding in June 1956, TECO Electric and Machinery Co., Ltd. has never rested
or been satisfied with its current success, but rather always strives for continuous
improvement in all areas. Starting out only producing motors and heavy machinery,
the TECO group has extended its scope of operations into household appliances, air
conditioning systems, communications, semi-conductors, optronics, networks, soft-
ware infrastructure, financial investments, food services and distribution industries,
making it now a globalized, hi-tech enterprise group. TECO is forever dedicated to
long-term development by creating new competitive advantages, enhancing services
quality, developing exceptional personnel and creating outstanding products.

Company philosophy
"First-class talents, seeking value-added work; first-class products, zero customer com-
plaint", this is the quality vision of strict observance for Tunchen (TECO Jiang Xi), and
coupling with the enterprise spirit of "honesty, pragmatism, speed, innovation", it
greatly enhances the company's cohesion and prepares the necessary conditions for
Tunchen (TECO Jiang Xi) to have the development and expansion today.
02

Specification and Benefit


Water-cooled packaged unit – High efficiency

World brand scroll compressor – Quality reputation

No pipe insulation – Low installation cost

Electro-mechanical control – Reliability

Compact indoor unit – Serviceability

R410A refrigerant – Eco-friendly

Low technical barrier – Low risk

Anti-freezing / overload protecotr – Multiple protection

Satisfies the special requirement of various customers – Customized


03

Model Nomenclature
PWC-D350MM
P TECO Air conditioning series products

W Water-cooled packaged air conditioner

C- R-410A Refrigerant

D Manufacturing factory

350 Cooling capacity, 350 x 0.1kW = 35kW

M Power supply, 3Φ, 380/415V, 50Hz

M Medium pressure (≦100Pa); P: high pressure (≧100pa)


04

Water-Cooled Packaged (R410A) Specifications


Type Free-blow type Ducted type
Model PWC-D280M PWC-D350M PWC-D280MM PWC-D350MM PWC-D500MM PWC-D680MM PWC-D850MP PWC-D1050MP PWC-D1200MP PWC-D1400MP

Cooling capacity kw 26.5 35.2 26.5 35.2 52.9 67.5 85.3 104.6 119.5 139.4
Electric heater heating
capacity (optional) kw 13.5 26.4 28.8 36(48)

Air flow m3/h 4800 5400 4000 4800 7800 9000 13600 16200 19800 21600
External Standard Pa 0 0 78 98 147
static
pressure Optional Pa ----- ----- ----- ----- 0-300(Plenum) 100-350 100-400
Power supply 3Φ-380V-50Hz/3Φ-415V-50Hz
E.E.R w/w 3.66 3.93 3.55 3.86 3.64 3.78 3.79 3.76 3.39 3.63
Power consumption kw 7.25 8.95 7.47 9.12 14.52 17.85 22.5 27.8 35.3 38.4
Running current A 13.8/12.30 17/15.19 14.2/12.68 17.3/15.47 27.6/24.64 31.9/30.29 42.7/38.18 49.7/47.17 63.1/59.89 68.6/65.15
Start current A 135 135 135 135 122 203 253 223 267 298
Type Scroll compressor
Starting method DOL
Compressor Output kw 5.7×1 7.5×1 5.7×1 7.5×1 5.2×2 7.5×2 9.0×2 7.5×3 9.0×3 5.2×6
Refrigerating oil PVE FV68S PVE FVC68D PVE FVC68D FV68S
Oil volume L 2.66×1 2.66×1 2.66×1 2.66×1 1.7×2 2.66×2 3.0×2 2.66×3 3.0×3 1.7×6
Refrigerant type R410A
Refrigerant charge volume kg 2.5×1 3.0×1 2.5×1 3.0×1 3.5×2 5.0×2 6.5×2 3.0×3 6.5×3 3.5×3
Refrigerant control method Capillary tube
Running control method Micro-computer
Indoor temp. controlling device Thermostat
Type Double-suctuin sirocco fan
Quantity 2 2 1 2 2 2 2 2
Fan
Fan motor output kw 0.39 0.39 0.68 0.68 2.2 4.0 5.5 5.5 5.5 7.5
Drive method Direct drive Belt-drive
Evaporator Louver type aluminum fin/Copper tube evaporator
Row/ Number of
cooling fins per inch 3/12 4/12 3/12 4/12 4/12 4/12 3/12 4/12 4/12 4/12

Type Shell and tube


Water flow m3/h 5.7 7.5 5.7 7.5 11.3 14.5 18.3 22.4 25.6 29.9
Head loss kPa 22.0 25.0 29.4 29.4 40.0 40.0
Water inlet inch/mm 1-1/2"/DN40 1-1/2"/DN40 2"/DN50 2-1/2"/DN65
pipe diameter
Condenser Water outlet inch/mm 1-1/2"/DN40 1-1/2"/DN40 2"/DN50 2-1/2"/DN65
pipe diameter

Condenser drain hole inch/mm 1"/DN25 1"/DN25 1"/DN25 1-1/4"/DN32

Mechanic chamber inch/mm 1"/DN25 1"/DN25 1"/DN25 1-1/4"/DN32


drain hole
Air filter screen Cleanable nylon fiber
Fresh air intake From both side by ducting From by back
Height mm 1900/2092 1620/1812 1875/2042 1880/2080
Width mm 1178/1292 1178/1292 1549/1673 1735/1859 1910/2065
Depth mm 485/598 485/598 630/753 970/1034 1084/1148
Net weight/ Gross weight kg 268/278 275/285 253/263 256/266 445/462 514/533 662/695 759/802 797/825 899/929
Compressor Inside temperature protect & Over current relay
Fan motor Inside temperature protect Over current relay
Phase sequence Phase sequence protection
Protection protection
device High pressure switch MPa(G) 3.2
Low pressure switch MPa(G) 0.12
Fusible plug YES
Control loop 5A fuse

1.The cooling capacity was measured under the condition of return air temp, 27° C DB, 19° C WB; Cooling water temp, inlet 30° C, outlet 35° C.
2.Due to TECO's continuous development and improvement process, the specifications are subject to modification without notice.
05

PWC-D280M/PWC-D350M

PWC-D280MM/PWC-D350MM
1
2
3
4
5
6
06

PWC-D500MM 1
2
3
4
5
6

PWC-D680MM 1
2
3
4
5
6
07

PWC-D850MP/PWC-D1050MP
1
2
3
4
5
6
7
8

PWC-D1200MP
08

PWC-D1400MP

Plenum(Optional)
The plenum is required if the ducted packaged air conditioner is to be modified into a free
blow air conditioner.

Weight External dimensions External


Model Application with/without without packing dimonsionswith packing
packing
PZPW15-l PWC-D500MM 24/26kg H302xW1549xD630mm H387xW1629xD695mm

PZPW20-l PWC-D680MM 33/35kg H302xW1735xD630mm H387xW1815xD695mm

Hot-Water Coil(Optional)
Model PZRP-24C PZRP-38C PZRP-54C PZRP-54C
Applicable models PWC-D280M(M) PWC-D350M(M) PWC-D500MM PWC-D680MM PWC-D850MM
Heating capacity(kw) 24 38 54 70
Model PZRP-38C PZRP-54C PZRP-54C
Applicable models PWC-D1050MP PWC-D1200MP PWC-D1400MP
Heating capacity(kw) 87 100 110

For more details, please refer to the product mamual.


09

Static Pressure of Air Flow


Curve Diagram for Static Pressure of Air Flow
30

25
PWC-D1400MP

20 PWC-D1200MP
Air Flow (x1000m3/h)

PWC-D1050MP

15 PWC-D850MP

PWC-D680MM
10
PWC-D500MM

0 20 40 60 80 100 120 140 160 180 200 220 240

External Static Pressure (Pa)

Installation of Electric Comporents


The electric components shall be installed in compliance with the relevant standards and
regulations. You many refer to the following specifications.

Minimum diameter of cord(mm² )


Item Power (Metel pipes, plastic pipes) Manual Switch (A)
GFCI(Ground Fault
Model Supply Power Supply Grounding Cable Circuit interrupter)
(code<30m) Capacity Fuse
PWC-D280M
PWC-D280MM
PWC-D350M
10 10 75 60 100mA
PWC-D280MM

PWC-D500MM 3Ø
PWC-D680MM 380V 25 10 150 100 100mA
PWC-D850MP 50Hz
PWC-D1050MP
PWC-D1200MP 35 16 150 100 100mA
PWC-D1400MP
10

Installation

Required space for the installation of equipment


installation of equipment
Unit: mm

>500

Rear Side Front Side


>500 >1000

>500