Vous êtes sur la page 1sur 4

Backscatter

Protection Zone
Safe for handheld use
The external backscatter shield and internal radiation
shielding are specially designed to protect the operator
from radiation exposure. In fact, the exposure from using
NOMAD is orders of magnitude less than exposure allowed
by the FDA. NOMAD radiation exposure is actually less than
1% of the allowed occupational doses. NOMAD is safe!

Whole Body Radiation Exposure


50 mSv Occupational Allowance

3.65 mSv Yearly Background Exposure from Normal Activities

.65 mSv Yearly Exposure Using NOMAD with D-Speed Film


.26 mSv Yearly Exposure Using NOMAD with a Digital Sensor

Radiation exposure using NOMAD, in millisieverts (mSv), is shown for


clinical scenario with one operator doing 7,500 x-rays per year.

All photos are courtesy of Dr. Eric Vogel, DDS, and Eileen Bidstrup

Highest quality
images and lowest
patient dosage
It has been clinically shown that NOMAD
produces diagnostic-quality x-rays and Depth and placement Placement of implant Implant placement following sinus lift
check during implant after surgery
will work equally well with both film and procedure
digital imaging media. NOMAD provides
all the benefits of DC performance: highest
quality images and lowest patient dosage.
NOMAD’s high-frequency, 60kv DC x-ray
generator provides constant radiation
output. This improves image quality while
reducing the dose to the patient relative to
traditional half-wave (AC) generators.
Verification of length during root
canal therapy

Post-operative root canal therapy

www.aribex.com
NOMAD ™

Handheld X-Ray
Now, you can safely take quality images with
a truly portable handheld x-ray—
Anytime...Anyplace!
This will change the way you practice dentistry
in many positive ways.

• Economical– One NOMAD can easily do the work of


multiple conventional wall-mount x-ray systems in clinical use
and it is unequalled for field work.

• Truly Portable– Weighing only 8 lbs, the battery-


powered NOMAD offers true portability with cordless opera-
tion and freedom from line voltage fluctuation. NOMAD can
easily take more than 100 exposures on one battery charge.

• Improves Quality and Workflow– Now take an


x-ray anytime during a procedure for verification. You’ll have
more diagnostic information when you need it. You’ll practice
better dentistry! NOMAD gets the x-ray to the patient, not the
patient to the x-ray­— you don’t even leave the room! This
improves work flow and saves time.
“It’s so easy to use and it saves time!”
• Easy to Use­– The only input you need is the exposure
time, entered through the user-friendly digital control panel.
It’s easier for you and more comfortable for the patient. The
ease of use and time savings is especially effective with
children.

• Works Wherever You Go– NOMAD is perfect for


traveling humanitarian/mobile dentistry with minimal equip-
ment and facilities.

Using NOMAD is quicker and more comfortable for


the patient.

www.aribex.com
NOMAD Handheld X-Ray System Products
Part No. Model Descriptions
FP-0001 NOMAD Dental NOMAD Intraoral, Dental X-Ray System, 110/120V AC Battery Charger
FP-0002 NOMAD CE Dental NOMAD Intraoral, Dental X-Ray System, 220/240V AC Battery Charger
FP-0003 NOMAD CE Examiner NOMAD Examiner, X-Ray System, 220/240V AC Battery Charger, Forensic, Veterinary,
Industrial Applications. CE marked
FP-0004 NOMAD Examiner NOMAD Examiner, X-Ray System, 110/120V AC Battery Charger, Forensic, Veterinary,
Industrial Applications.

NOMAD Handheld X-Ray System Accessory Items


Part No. Applied to Models Descriptions
MP-0018 All NOMAD Models NOMAD Hard-Shell Carrying Case with Wheels and Telescoping Handle
CP-0001 All NOMAD Models NOMAD Rechargeable Battery Pack, 14.4V DC
CP-0002 NOMAD Dental NOMAD Battery Charger, 110/120V AC
NOMAD Examiner
CP-0045 NOMAD CE Dental NOMAD Battery Charger, 220/240V AC
NOMAD CE Examiner
MP-0034 All NOMAD Models NOMAD Positioning Stand with Remote

The NOMAD system comes with 2 batteries and a battery


Tech Specs
charger. Hard-shell carrying case is optional. Aribex NOMAD Intraoral X-Ray Source
Technical Specifications
Battery NiCd, 14.4V, 2 Ahr
Anode voltage 60 kV true DC
Anode current 2.3 mA
Exposure time range 0.01 - 0.99 s
Focal spot 0.4 mm
Inherent filtration >1.5 mm Al
Source to skin distance 20 cm
X-ray field 60 mm round
Maximum duty cycle 1:60
Total weight <4 kg
Approximate dimensions W 5.25” L 10.0” H 9.5”

Complies with DHHS Rules, 21 CFR Subchapter


J applicable at time of manufacture

Aribex, Inc.
744 South, 400 East
Orem, UT 84097 USA
Phone: 801-226-5522
Toll Free: 866-340-5522
Fax: 801-434-7233

www.aribex.com
US and foreign patents pending. ©2007 Aribex, Inc. • MC-0001, Rev. F. April 2007