Vous êtes sur la page 1sur 3

EIA of Bhopal Smart City Project

Table 4-14: Ground Water Sampling Data Analysis

Ground Water Standards4


Mordan Doordarshan Mata Mandir
Sr. Parameters Unit Tulsi Nagar Kamla Lake IS 10500
School Colony Chauraha
No
. NIL/W/12/16/01 NIL/W/12/16/01 NIL/W/12/16/01 NIL/W/12/16/01 NIL/W/12/16/0
1 2 3 4 15 Permissible
Limit
Date of Sampling – 02.12.2016 02.12.2016 02.12.2016 02.12.2016 02.12.2016
0
1 Temperature C 23.9 24.0 24.2 24..6 24.8
2 Colour Hazan <5.0 <5.0 <5.0 <5.0 <5.0 5
3 Odour – Odourless Odourless Odourless Odourless Odourless
4 Turbidity NTU 7.9 3.1 0.1 8.7 4.8 1
Total Dissolved 500
5 mg/l 253 277 369 269 317
Solids
Total Suspended
6 mg/l <5.0 <5.0 <5.0 <5.0 <5.0
Solids
Total Alkalinity (as 200
7 mg/l 168 156 165.6 160.8 172.8
CaCO3)
8 Dissolved Oxygen mg/l 1.7 2.2 2.7 1.3 2.9
9 B.O.D. mg/l <4.0 <4.0 <4.0 <4.0 <4.0
10 C.O.D. mg/l 12 12 28 <10 <10
11 Nitrate mg/l <0.5 2.15 2.75 <0.5 2.6 45
12 Total Phosphorus mg/l <0.5 <0.5 <0.5 <0.5 <0.5
13 Chlorides (as Cl) mg/l 48.21 47.24 54.96 44.35 25.07 250
14 Sodium (as Na) mg/l 31.6 26.2 35.24 30.4 26.4

4
IS 10500

EIA REPORT: Bhopal Smart City Area Development Project 136


EIA of Bhopal Smart City Project

Ground Water Standards4


Mordan Doordarshan Mata Mandir
Sr. Parameters Unit Tulsi Nagar Kamla Lake IS 10500
School Colony Chauraha
No
. NIL/W/12/16/01 NIL/W/12/16/01 NIL/W/12/16/01 NIL/W/12/16/01 NIL/W/12/16/0
1 2 3 4 15 Permissible
Limit
Date of Sampling – 02.12.2016 02.12.2016 02.12.2016 02.12.2016 02.12.2016
15 Potassium (as K) mg/l 1.7 2.7 0.90 2.8 <0.1
16 Calcium (as Ca) mg/l 47.88 49.4 68.4 50.16 52.44 75
Magnesium (as 30
17 mg/l 11.85 10.48 8.66 10.94 11.85
Mg)
18 Oil & Grease mg/l <0.2 <0.2 <0.2 <0.2 <0.2
19 Sulphate (as SO4) mg/l 23.72 19.68 49.11 24.94 22.85 200
20 Fluorides (as F) mg/l <0.2 <0.2 <0.2 <0.2 <0.2 1
21 Salinity ppt 0.12 0.11 0.13 0.11 0.07
Ammonical
22 mg/l <0.4 <0.4 <0.4 <0.4 <0.4
Nitrogen
Phenolic 0.001
23 mg/l <0.001 <0.001 <0.001 <0.001 <0.001
Compounds
Total Hardness 200
24 mg/l 169.1 167.2 207.1 171 180.5
(as CaCO3)
Polychlorinated 0.0005
25 mg/l <0.0001 <0.0001 <0.0001 <0.0001 <0.0001
biphenyl (PCB)
Total Petroleum
26 mg/l <0.0001 <0.0001 <0.0001 <0.0001 <0.0001
Hydrocarbon
27 Pesticides mg/l <0.0001 <0.0001 <0.0001 <0.0001 <0.0001
28 Arsenic (as As) mg/l <0.01 <0.01 <0.01 <0.01 <0.01 0.01
29 Iron (as Fe) mg/l <0.01 <0.01 <0.01 <0.01 <0.01 0.3
30 Copper (as Cu) mg/l <0.04 <0.04 <0.04 <0.04 <0.04 0.05
31 Lead (as Pb) mg/l <0.01 <0.01 <0.01 <0.01 <0.01 0.01

EIA REPORT: Bhopal Smart City Area Development Project 137


EIA of Bhopal Smart City Project

Ground Water Standards4


Mordan Doordarshan Mata Mandir
Sr. Parameters Unit Tulsi Nagar Kamla Lake IS 10500
School Colony Chauraha
No
. NIL/W/12/16/01 NIL/W/12/16/01 NIL/W/12/16/01 NIL/W/12/16/01 NIL/W/12/16/0
1 2 3 4 15 Permissible
Limit
Date of Sampling – 02.12.2016 02.12.2016 02.12.2016 02.12.2016 02.12.2016
32 Mercury(as Hg) mg/l <0.001 <0.001 <0.001 <0.001 <0.001 0.001
Mangenese (as 0.1
33 mg/l <0.1 <0.1 <0.1 <0.1 <0.1
Mn)
34 Zinc (as Zn) mg/l 0.5 0.4 <0.1 0.21 <0.1 5
Total Chromium 0.05
35 mg/l <0.04 <0.04 <0.04 <0.04 <0.04
(as Cr)
36 Selenium (as Se) mg/l <0.01 <0.01 <0.01 <0.01 <0.01 0.01
37 Cadmium (as Cd) mg/l <0.005 <0.005 <0.005 <0.005 <0.005 0.003
38 Boron (B) mg/l <0.4 <0.4 <0.4 <0.4 <0.4 0.5
Nos./100 Should be nil
39 Total Coliforms 2 540 13 540 70
ml in 100 ml
40 Fecal Coliforms – Absent Present Absent Present Absent
41 Zooplankton – Absent Absent Absent Absent Absent

EIA REPORT: Bhopal Smart City Area Development Project 138