Vous êtes sur la page 1sur 2

MAGNETIC PARTICAL TEST REPORT

DC NO: RGP/20160254

PITTI LAMINATIONS REPORT NO


CLIENT AES/PITTI/16/14
LIMITED DATE

TEST PART 166 G3 -STUDS TEST DATE 26.05.2016

NAME OF THE
MATERIAL EN-24 NAGENDRA BABU
INSPECTOR
REFERENCE
DOCUMENT
ASME SEC-V SIZE ¾”DIAX466mmLENGTH

APPLICABLE CONTINUOUS WET


AMS2301,2640 TEST TECHNIQUE
SPECIFICATION FLOUROSCENT

EQUIPMENT MAKE AMPERAGE CURRENT

YOKE SIMS, HYDERABAD ---- AC/HWDC

COIL SIMS, HYDERABAD 500 HWDC

DETECTING 10gm/1Lit(MANUFACTURERE
WET FLUROSCENT CONCENTRATION
MEDIUM RECOMENDATION)
ASTMFIELD
ACCESSORIES RESIDUAL FIELD LESS THAN +3 GUASS
INDICATOR,GUASS
METER ,UV LIGHT

Total Qty Total Qty Total Qty


Sl no Description Size Accepted Qty Observation
Received inspected Defective

1 166 G3 -STUDS
¾”DIAX466mm 100 100 91
Linear
09
LENGTH Indications

Result: Relevant linear indications found on 09 studs.

NDT INSPECTOR

NAME NAGENDRA BABU

SIGNATURE & DATE

Vous aimerez peut-être aussi