INSTRUCTION MANUAL FOR

PRESSURE SWITCHES — SERIES GH–900

INTRODUCTION Do not establish pressure connections by


rotating the housing. Hold hexagon (20 A/F)
SWITZER GH Series 900 instruments are suitable of the sensor housing tight with a suitable
for Air, Gas, Water, Steam, Oil, etc. The sensing spanner and establish connections.
element is a hydraulically formed seamless
phosphor bronze bellows in a brass housing or
316 LSS Bellows in 316 SS housing fixed SETTING OF THE SWITCHING POINTS
external to the robust pressure die cast
weatherproof Aluminium housing. Loosen the lock plate screw to unlock the range
adjuster (and also that of the differential
The range and differential setting screws are adjustable screw in case of differential model).
externally accessible. Locking arrangement is
provided on the body to avoid tampering. Rotate the range adjuster suitably to select the
switching point either for fall in pressure or rise
in pressure.
MOUNTING / CONNECTIONS / PRECAUTIONS
On adjustable differential models use range screw
Mount the instrument rigidly direct on the pressure to set the lower switching point and then adjust
piping or on a vibration free wall or panel. the differential screw to set the upper switching
point.
The switching points should normally be in the
mid 35 to 70% of the adjustable range span. Turning the range adjuster anti-clockwise shifts
both upper and lower switching points upwards.
Read the name plate data carefully and do not
exceed maximum working pressure and electrical Turning the differential adjuster anti-clockwise
ratings. shifts only upper switching point upwards
i.e., the switching pressure difference alone
To make the instrument weatherproof use correct increases.
weatherproof cable gland and ensure its
tightness. The upper switching point should not exceed
maximum range value.
If outdoor installation is envisaged, provided
sufficient protection against aggressiveness of The range scale markings provided are for
air, dust, very high or very low temperature, approximate settings only. To set switching points
solar radiation, water penetration etc. precisely use a master pressure gauge.

For applications with pressure fluctuations install Tighten the lock screws.
a dampener to eliminate chattering of microswitch
and excessive pressure cycling of bellows. For In instruments with two SPDT switches for DPDT
steam, use a condensor coil or a syphon. action, the synchronisation of actuation is done
within practical limits. The switches are
If process temperature is higher than 70°C at synchronised as per customer preference, either
the instrument end, it can be brought down by on “falling” or on “rising” pressure. If no
using longer pressure piping. Ask factory for preference is indicated, synchronisation is done
piping nomogram. for FALL in pressure at factory.
MOUNTING DIMENSIONS

20.0 115.0
104.0 9.5 36.0

LOCKING
DEVICE

24.0

81.0 90.0

3/4" ET PVC
CABLE GLAND

A±2 SENSING
ELEMENT
(BELLOWS)
MOUNTING LUGS

35.0
23.0
PROCESS
CONNECTION
All dimensions are in mm.

M.W.P. (B ar ) M.P.P (b ar ) Ran g e Co d e PS


PS SS
SS
Ran g e Co d e
Co d e Di men s i o n
(B ar ) F, H, J, K & L 37.5
PB / SS PB
PB SS
SS A–2
–2
54.0
M&N 65
F 0 1.6 4 4 10

H 0 4 9 9 10
Notes

J 0 7 18 25 36 1. Process Connection 1/4" NPT(F) standard and through


adaptor optional.
K 0 10 18 25 36
2. Ask for dimensional drawing for instrument with Switch
Code ‘33X’ and ‘DD’.
L 0 16 25 25 36
3. Weatherproof only when all entries and joints are
M 0 25 36 40 36 suitably sealed.

4. Mounting lugs and screws with instructions for use


N 8 32 36 40 36 are supplied separately.

SWITZER INSTRUMENT LIMITED


# 0601 IM–GH900 – Rev.01

Internet web–site
Regd. Off : 14, Thanikachalam Road, P.B.No.1423, Chennai 600 017. www.switzer@switzerinstrument.com
SALES – HEAD OFFICE WORKS OFFICE
9, South Boag Road, T. Nagar, Chennai 600 017 127 Sidco Estate, Ambattur, Chennai 600 098
Ph : 044–4340999 / 4343956 / 4344321 Fax : 044–4347887 Ph : 044–6242244 / 6242255 / 6243355 / 6248849 Fax : 044–6258739
E–mail : sales@switzerinstrument.com E–mail : switzer@eth.net ; works@switzerinstrument.com

Vous aimerez peut-être aussi