Forces Moments

Node Load Combination


Fx Fy Fz Mx My Mz

1
1
1
Type
Footing for Nodes 1 2
F1
A) Material Properties
fck = 25 N/mm2
Concrete fy = 415 N/mm2
gc = 25 kN/m3
Net SBC = 180 kN/m2
gs = 18 kN/m3
Soil
Gross SBC = 201.6 kN/m2
Gross SBC for EL = 246.6 kN/m2
B) Section Details
Lx = 3000 mm
Footing Lz = 2100 mm
D = 600 mm
Cx = 300 mm
Column
Cz = 500 mm
Cover = 50 mm
ØX = 16 mm
Effective Depth ØZ = 10 mm
Calculation
dx = 542 mm
dz = 529 mm
DOF = 1200 mm
FGL = 13.2 mm
Depth Details BOF = 12 m
NGL = 13.43 mm
Diff b/w NGL-FGL = 0.23 mm
C) Load Details
Weight of Footing = 94.5 kN
Weight of soil = 66.42 kN
Soil Filling Weight = 0 kN
Additional Load = 20 kN/m2
Surcharge = 4.14 kN/m2
Total Surcharge acting = 24.14 kN/m2
Surcharge Load = 148.461 kN

Total Weight acting = 309.381 kN

Footing Details
Lz

Lx
Eco Protection Engg., Pvt Ltd
Structural Design Calculation

Design of Isolated Footing


Reference Node
Footing Number

Design Parameters
Grade of Concrete fck= 25 N/mm2
Grade of Steel fy= 415 N/mm2
Clear Cover to main reinforcement = 50 mm
Unit weight of Concrete = 25 kN/m3
Unit weight of Soil = 18 kN/m3
Net Safe bearing capacity of the soil SBC = 180 kN/m2
Gross Safe bearing capacity of the So GSBC= 201.6 kN/m2
Gross Safe bearing capacity of the soil (EL/SL 252 kN/m2
Depth of Foundation = 1.2 m
Difference in Level b/w FGL & NGL = 0.23 m
Surcharge acting on the footing = 24.14 kN/m2

Section Properties
Lx Lz D Area (Af) Zxx Zzz
Footing 3 2.1 0.6 6.3 2.205 3.15
Cx Cz B/w FGL to TOF
Column 0.3 0.5 0.6 0.15
Load Calculations
Footing Weight (L*B*D) = 94.5 kN
Weight of Soil = 66.42 kN
Soil Filling Weight = 0 kN
Additional Load = 20 kN/m2
Surcharge = 4.14 kN/m2
Total Surcharge acting = 24.14 kN/m2
Surcharge Load = 148.461 kN

Total Weight W 309.381 kN


Staad Pro Input for Serviceability
Fy +
Addl
Node No L/C Weight
Fx Fy FZ Mx My Mz
kN kN kN kN m kN m kN m kN
1 0 0 0 0 0 0 0 309.381
2 0 0 0 0 0 0 0 309.381
3 0 0 0 0 0 0 0 309.381
4 0 0 0 0 0 0 0 309.381
5 0 0 0 0 0 0 0 309.381
6 0 0 0 0 0 0 0 309.381

5
Eco Protection Engg., Pvt Ltd
Structural Design Calculation

Design of Isolated Footing


Reference Node
Footing Number
7 0 0 0 0 0 0 0 309.381
8 0 0 0 0 0 0 0 309.381
9 0 0 0 0 0 0 0 309.381
10 0 0 0 0 0 0 0 309.381
11 0 0 0 0 0 0 0 309.381
12 0 0 0 0 0 0 0 309.381
13 0 0 0 0 0 0 0 309.381
14 0 0 0 0 0 0 0 309.381
15 0 0 0 0 0 0 0 309.381
16
17
18
19
20
21
22
23
24
25

Soil Pressure without weight of Footing & soil above Footing

Max Min
1 2 3 4
Node No L/C Pressure Pressure Check
for SBC
kN/m2 kN/m2 kN/m2 kN/m2 kN/m2 kN/m2
1 0 49.11 49.11 49.11 49.11 49.11 49.11 SAFE
2 0 49.11 49.11 49.11 49.11 49.11 49.11 SAFE
3 0 49.11 49.11 49.11 49.11 49.11 49.11 SAFE
4 0 49.11 49.11 49.11 49.11 49.11 49.11 SAFE
5 0 49.11 49.11 49.11 49.11 49.11 49.11 SAFE
6 0 49.11 49.11 49.11 49.11 49.11 49.11 SAFE
7 0 49.11 49.11 49.11 49.11 49.11 49.11 SAFE
8 0 49.11 49.11 49.11 49.11 49.11 49.11 SAFE
9 0 49.11 49.11 49.11 49.11 49.11 49.11 SAFE
10 0 49.11 49.11 49.11 49.11 49.11 49.11 SAFE
11 0 49.11 49.11 49.11 49.11 49.11 49.11 SAFE
12 0 49.11 49.11 49.11 49.11 49.11 49.11 SAFE
13 0 49.11 49.11 49.11 49.11 49.11 49.11 SAFE
14 0 49.11 49.11 49.11 49.11 49.11 49.11 SAFE
15 0 49.11 49.11 49.11 49.11 49.11 49.11 SAFE
16

6
Eco Protection Engg., Pvt Ltd
Structural Design Calculation

Design of Isolated Footing


Reference Node
Footing Number
17
18
19
20
21
22
23
24
25

Maximum Pressure (P max) = 49.11 kN/m2


Minimum Pressure (P min) = 49.11 kN/m2

P max is less than GSBC ,Hence Safe

Soil Pressure without weight of Footing & soil above Footing

Max Min
1 2 3 4 Check
Node No L/C Pressure Pressure
for SBC
kN/m2 kN/m2 kN/m2 kN/m2 kN/m2 kN/m2
1 0 0 0 0 0 0 0 SAFE
2 0 0 0 0 0 0 0 SAFE
3 0 0 0 0 0 0 0 SAFE
4 0 0 0 0 0 0 0 SAFE
5 0 0 0 0 0 0 0 SAFE
6 0 0 0 0 0 0 0 SAFE
7 0 0 0 0 0 0 0 SAFE
8 0 0 0 0 0 0 0 SAFE
9 0 0 0 0 0 0 0 SAFE
10 0 0 0 0 0 0 0 SAFE
11 0 0 0 0 0 0 0 SAFE
12 0 0 0 0 0 0 0 SAFE
13 0 0 0 0 0 0 0 SAFE
14 0 0 0 0 0 0 0 SAFE
15 0 0 0 0 0 0 0 SAFE
16 0 0 0 0 0 0 SAFE
17 0 0 0 0 0 0 SAFE
18 0 0 0 0 0 0 SAFE
19 0 0 0 0 0 0 SAFE

7
Eco Protection Engg., Pvt Ltd
Structural Design Calculation

Design of Isolated Footing


Reference Node
Footing Number
20 0 0 0 0 0 0 SAFE
21 0 0 0 0 0 0 SAFE
22 0 0 0 0 0 0 SAFE
23 0 0 0 0 0 0 SAFE
24 0 0 0 0 0 0 SAFE
25 0 0 0 0 0 0 SAFE

Design of Reinforcement

Max Min
1 2 3 4 Check
Node No L/C Pressure Pressure
for SBC
kN/m2 kN/m2 kN/m2 kN/m2 kN/m2 kN/m2
1 0
2 0
3 0
4 0
5 0
6 0 0
7 0 0
8 0 0
9 0 0
10 0 0
11 0 0 SAFE
12 0 0 SAFE
13 0 0 SAFE
14 0 0 SAFE
15 0 0 SAFE
16 0 SAFE
17 0 SAFE
18 0 SAFE
19 0 SAFE
20 0 SAFE
21 0 SAFE
22 0 SAFE
23 0 SAFE
24 0 SAFE
25 0 SAFE

8
STAAD INPUT SECTION DETAILS SBC DETAILS PRESSURE DETAILS Moment

Moment along

Moment along
Moments

Modulus
Footing
Column

Section
Forces

Gross for

Total Load
EQ/WL

Pressure

Pressure
Area

Gross
Net
1 2 3 4

Z
P
Node

L/C

Max.

Min.
Fx Fy Fz Mx My Mz Cx Cz Lx Lz D Lx*Lz Zxx Zzz
kN kN kN kN m kN m kN m mm mm m m m Sq.m m3 m3 kN/m2 kN/m2 kN/m2 kN kN/m2 kN/m2 kN/m2 kN/m2 kN/m2 kN/m2 kN m kN m
0 0 0 0 0 0 0 0 300 500 3 2.1 0.6 6.3 2.21 3.15 180 201 246.6 309.381 49.11 49.11 49.11 #DIV/0! #DIV/0! #DIV/0!
0 0 0 0 0 0 0 300 500 3 2.1 0.6 6.3 2.21 3.15 180 201 246.6 309.381 49.11 49.11 49.11 #DIV/0! #DIV/0! #DIV/0!
0 0 0 0 0 0 0 300 500 3 2.1 0.6 6.3 2.21 3.15 180 201 246.6 309.381 49.11 49.11 49.11 #DIV/0! #DIV/0! #DIV/0!
0 0 0 0 0 0 0 300 500 3 2.1 0.6 6.3 2.21 3.15 180 201 246.6 309.381 49.11 49.11 49.11 #DIV/0! #DIV/0! #DIV/0!
0 0 0 0 0 0 0 300 500 3 2.1 0.6 6.3 2.21 3.15 180 201 246.6 309.381 49.11 49.11 49.11 #DIV/0! #DIV/0! #DIV/0!
0 0 0 0 0 0 0 300 500 3 2.1 0.6 6.3 2.21 3.15 180 201 246.6 309.381 49.11 49.11 49.11 #DIV/0! #DIV/0! #DIV/0!