Vous êtes sur la page 1sur 7
‘SITE ACCEPTANCE TEST FORMAT FOR SYNCHRO CHECK RELAY ~ RMS-2SY212 recieNT: reece Gee Gerrteay WeseCemorten (CONSULTANT: iE THAIN CONTRACTOR SIEMENS ENERGOPROJEKT — QATAR POWER TRANSMISSION SYSTEM EXPANSION | Contract No GroeKsA2016 PHASE 12 SUBSTATIONS - PACKAGES 1, 92, 86887 [paw 02012017 Name ofSubstaion > (9018/11 KVWAKRAH REPALCEMENT SS [Bay Number 415V LVAC = ABO Name of Eaupreit 1 256-SVHHCH CHECK RELAY Manufactver = SIEWENS List of Content Sl.No Description Page No 1 Relay Oatalls 2 2 vrodtais 2 3 Wisval Check, 2 4 Watchdog Contact Checks. 2 s Measured Value Test. 3 5.4, VT Measurement 3 6 Synchro check test 3 6.1, LVAG-Synch Check Relay... 3 6.1.1 Voltage Difference 4 6.1.2 Phase Angle Difference 4 6.1.3 Frequency Difference 4 6.1.4 Energzation (Threshold) Check 5 6.1.5 Synchro Block Check. s 7 Binary Inputs Test 5 & Binary Outputs Test 6 LED Indication Test 6 10 Scheme Check 7 11 Instruments Used 7 SIEMENS ENERGOPROJEKT-ENTEL | KAHRAMAR ete a4 sone | Name M.Shaker - Name M.Umapathy. Date (02/0172017 Date 02/0172017 | DociNo. | PHI2 Vi (V)= 5.0 Setting Vi < Vs (V) = 0 Range: 2V to 4aV in 0.5 V steps Bus i vokage | Une VEvaone | vag gee vot (ots) (volts) Expected actual av = 5 Since syne O« Vi= 110 AV =5.2 ‘Sync Fail ‘Sync Fail vis no a aa sync sync 0« v= 10 aves syne Fil syneFeil 105.2 AV =4.8 Sync Ok ‘Sync Ok “V.= 105 viento aves sync Fa syncFall viens venta aves syne Ok sync Oe 1152 vente aves Sync Fi Smell Acceptance Norm: Tolerance iV of AV — SEMENS- ENERGOPROJEKT/ENTELT KAHRAWAA Sonaure | > somue | po [name | M.Shaker Name | M.Umapathy _ tate | e2nwa017 nie | e2nva017 Doc No. _| PHI2-3A-10-36-P041 Rev. 0 Annexure [1 Page No. 30f7 SITE ACCEPTANCE TEST FORMAT FOR SYNCHRO CHI |ECK RELAY ~ RMS-28Y212 ec [SONSULTANT: WAI CONTRACTOR ramon Ul A Mapilenats gl ME ENERGOPROJEKT wr esta nas EEN cam QATAR POWER TRANSMISSION SYSTEM EXPANSION | Comtact No. Groiesaw2014 PHASE 12 SUBSTATIONS - PACKAGES 1, 82, 86&S7 [date (21012017 [Name of Substation 782165/11 KV WAKRAH REPALCEMENT SS Bay Number 415V LVAG - ABO. Name ofEqupment ___258-SYNCH CHECK RELAY Monvlactuer SIEMENS 6.1.2, PHASE ANGLE DIFFERENCE (4a): ‘ba = function: jetting 02 > a1 (°) = 20° Setting o2< a: (°) 20° Range: 5° to 90° In 1* steps Bee Vrsnole S| nev anale eae oid canki (dearee/*) (deoree/*) (degree/*) ~[ Aetuat o1=0° a2 = 20.6 ‘ha = 20.6 ‘Syne Ok a2 = 20.7 ‘Sync Fal ‘Syne Fail a2 = -19.2 | syne ok syne Ok a2 = 19.4 Sync Fail ‘Syne Fail a= 0 7 Syne Ok ‘Sync Ok as= 0° ‘Syne Fail Sync Fall a= 0 ‘syne Ok “sync Ok re Syne Fail ‘Syne Fall Acceptance Norm: Tolerance + 1¢ of Aa 6.1.3, FREQUENCY DIFFERENCE (Af) ‘Af = function setting fi > fr (Hz) = A Setting f< fs (Hz) = 0.1 Range: 0.05 to 2.00Hz in 0.01Hz rraquaney(tt) | Frequency (t2)_|_itterence (40 Swctonaises (Hz) (Hz) (Hz) Expected Actual f= 50.00 Hz f= 50.11 ‘Syne Ok Sync Ok fi = 50.00 He fe =50.12 Syne Fall Syne Fall fi = 50,00 Hz fo =49,89 syne Ok sync Ok f= 50.00 Hz Syne Fail Syne Fal fi =50.11 ‘Syne Ok Syne Ok fz =50.12 ‘Sync Fail ‘Syne Fail f2 =49.89 Sync Ok Syne Ok f=49.88 Syne Fall Sync Fall ‘eceptance Norm: Tolerance 10.05Hz of AF ‘SIEMENS ENERGOPROJEKT-ENTEL / KAHRAMAA Signature aan sonaure | Q-— Name M Shaker Name MUmapathy. vate | ozoveor7 ee Doone | PHI2-3A.1035 POH a oe Pages 4ot7 ecienr car sen Sin oo apr ores Qua Gerlich se Conention NSULTANT: ENERGOPROJEKT TWAIN CONTRACTOR: SIEMENS SITE ACCEPTANCE TEST FORMAT FOR SYNCHRO CHECK RELAY ~ RMS-2SY212 QATAR POWER TRANSMISSION SYSTEM EXPANSION eOMisaeR Os SIGINT PHASE 12 SUBSTATIONS ~ PACKAGES S1,$2,$6&S7 | date 02012017 Name ofSubstaion 1328/11 KV WAKRAH REPALCEMENT SS [Bay Number 416V LVAG ABO Name offquipment_- 256-SYNCH CHECK RELAY Manulactuer SIEMENS 6.1.4, ENERGIZATION CHECK: Minimum Voltage for Synchronisation: Setting of Threshold Vs, Vwithout vltage = 45 oy Setting of Thresnold Vi, Vit voltage =v vi v2 Test for Syne Condition 80 45 | viv anava< | live Bus - Dead tine Ok 45 a5 |_vicana vez | bead Bus - Dead Line Natok | 80 80 | Vir ond Var | Live Bus Line Line Ok 45 80 | Vieandva>_| Dead Bus Live Line Ok 6.1.5, Synchro Function Block SL.No. _| Function Description Tested () | Remarks B.L5.1 | Selected LVAC Line VT MCB Off /Trioned ao WA 5.1.5.2 | Selected LVAC Line VF in Test Postion og WA 5.15.3 | Selected LYAC Bus VT NCB Off / Tipped oO NA 5.1.5.4 | Selected LVAC Bus VT in Test Postion oa 5.1.5.5 _ | V1 Selection Switch S05 in IN Postion oD Wa 7, BINARY INPUT: Binary Input check: BE No, [oF Assigned woos por approved schematic @anings Tesiea(SS) | Remarks 1 Symchroriom check noble a _ 2 Srochvoriem check Stat a > Shnchvoritm check bypass ge enable a 4 emote reset Oo SIEMENS ENERGOPROJEKT-ENTEL) KAHRAMAA Sones ah sonave | Nae | MShaker Wane | N.Umapathy Dae [02012017 pate | oaoweorr Doce | PHI2aA-1036POa1 nev [0 __[ Arnone wi B07 SITE ACGEPTANGE TEST FORMAT FOR SYNCHRO CHECK RELAY ~ RMS-287212 ace SoEUTTANT: TI COMTARCTOR: ENERGOPROJEKT venous no oe a | AE SIEMENS QATAR POWER TRANSMISSION SYSTEM EXPANSION ‘Contract No. GTCIGASA/2014 PHASE 12 SUBSTATIONS - PACKAGES $1, S2, $6 & S7 Date 0210 1/2017 Narre of Subsaton 15268711 RV WAKRAH REPALGENENT SS Bay Number s18V LVAD Nore of Equprert 266-6YNCII CHECK RELAY Warafucuror SIEMENS 8. BINARY OUTPUT: Binary Output check: BONe. __ | BO Assigned to as per approved Schematic drawings Tested (E2) 1 Synchronism check Close IC-1 a Syachronism check Close 8C ‘Synchronism check Close IC-2 QN3 ACB test synch relay OK QHZ ACE test synch relay OK a Ey QUI ACB test syach relay OK a a a a wve Contact | Check Contact change over from NC to NO during Unhealthy LED INDICATION: LED Indication check: LEO No. | LED Assigned to a3 per approved Schem: Tested (1) | Remarks tne | check synch Cove ze [Synch enabie a RED | Synch bypass enabled & 4-RED Healthy Bw S-RED ‘Synchronized a ERED | Under votape cose Bozk B rereen | Heatny ened | senice ‘SIEMENS ENERGOPROJEKT-ENTEL/ KAHRAMAA Sgnature a Sanave | Name [ WShaker Name | MUmapathy one | o2ov20W date | oaioveosr DocNo | PH12-3A.10-36-P04T Rev Q Annexure [1 Page No 6of7 ‘CONSULTANT: Fn A Mays | E ENERGOPROJEKT TEE aHecined ck awe oprtin SITE ACCEPTANCE TEST FORMAT FOR SYNCHRO CHECK RELAY ~ RMS-25Y212 WAINGONTRACTOR: SIEMENS QATAR POWER TRANSMISSION SYSTEM EXPANSION | Contact No. PHASE 12 SUBSTATIONS - PACKAGES St, 82, 86&S7 [pate Name of Substation 132/65/1KV WAKRAN REPALCEMENT SS [Bay Number: 416 LVAC-ABO [name or Eavpment : 258-SYNCH CHECK RELAY Menvfadiwer SIEMENS 10, SCHEME CHECK: Scheme Check: St.No. | Function Description [Tested (21) | Remarks 10. MCB Operation checked for VT Teolation a 10. ‘Synch Check Enable in Auto/tanual a 10. Relay found healthy Ey 11, INSTRUMENTS USED: sh Equipment Calibration due Ag | Description | Make / Model pe Calibration date ues 4 rnjection e_| Omécran 256 Bu627F Isjt0/.6 141017 2 Mutimeter | Fluke 25100177, 20/09/16 27/08/17 Remarks: _ cn ne SIEMENS ENERGOPROJEKT-ENTEL / KAHRAMAA Signature ay sirawe | Nane | WShaker Name | MiUmapathy. bate _| 2012017 bate | 021012017 pn Doe. | Pii23a 1036 POM a oo Baga Tol7

Vous aimerez peut-être aussi